Three stage pressure relief valve<br />
3RBE<br />
With shock damping valve<br />
(Y)<br />
X P T<br />
Overview<br />
This three stage pressure relief valve is a<br />
balanced piston type pilot operated relief<br />
valve integrating three pilot relief valves and<br />
one solenoid operated directional valve into<br />
one body, and can control the circuit pressure<br />
at two or three stages with electrical signals<br />
to the solenoid operated directional valve.<br />
Type indication<br />
Features<br />
1. The circuit pressure can be controlled at<br />
two or three stages without vent<br />
connection.<br />
2. Concurrent use of the shock damping<br />
valve (refer to the section of the type<br />
number index “ZNS5”) can perform<br />
shockless, smooth pressure change.<br />
3. Adoption of the unequal type for the main<br />
plunger has realized stable operation.<br />
Three stage pressure relief valve<br />
Three stage<br />
pressure relief valve<br />
Nominal dimension<br />
<strong>10</strong>, 20, 30<br />
Connection method<br />
P<br />
C<br />
<br />
<br />
Gasket connection type<br />
Cartridge type<br />
Series number: <strong>10</strong><br />
Shape of pressure adjusting part<br />
2 = Thread adjustment (with cap)<br />
Highest adjustment pressure<br />
<strong>10</strong>0 9.8MPa (<strong>10</strong>0kgf/cm 2 )<br />
315 30.9MPa (315kgf/cm 2 )<br />
Vent port<br />
No symbol<br />
Without vent port (in the case of flange connection type<br />
and cartridge type)<br />
X =With vent port (in the case of gasket connection type)<br />
Drain system<br />
No symbol = Internal drain<br />
Y = External drain<br />
Spool type of solenoid operated directional valve<br />
05=<br />
08=<br />
14=<br />
a<br />
a<br />
a<br />
A B<br />
P T<br />
A B<br />
P T<br />
A B<br />
P T<br />
b<br />
b<br />
Design No.<br />
Shock damping valve provided or not<br />
No symbol = Without shock damping valve<br />
S = With shock damping valve<br />
Electric connection symbol<br />
Symbol<br />
B<br />
C<br />
CL<br />
Explanation<br />
With DIN connector<br />
With DIN large connector<br />
With DIN large connector with lamp<br />
Input voltage<br />
12<br />
24<br />
<br />
<br />
<strong>10</strong>0 <br />
200 <br />
12V<br />
24V<br />
<strong>10</strong>0V<br />
200V<br />
Type of hydraulic oil<br />
No symbol = Mineral based hydraulic oil<br />
V = Phosphate ester based hydraulic oil<br />
W = Fatty ester based hydraulic oil<br />
W1 = Water-glycol based hydraulic oil<br />
Input power supply<br />
A = Alternating current<br />
D = Direct current<br />
R = AC/DC conversion<br />
Input power supply<br />
A D R<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
* For details of voltage specifications, refer to “Solenoid<br />
specifications” of the solenoid operated directional valve “DE5”.<br />
* For other power supply, please contact us.<br />
Solenoid type<br />
W = Wet type<br />
(with standard emergency manual operation)<br />
2-27