Three stage pressure relief valve<br />

3RBE<br />

With shock damping valve<br />

(Y)<br />

X P T<br />

Overview<br />

This three stage pressure relief valve is a<br />

balanced piston type pilot operated relief<br />

valve integrating three pilot relief valves and<br />

one solenoid operated directional valve into<br />

one body, and can control the circuit pressure<br />

at two or three stages with electrical signals<br />

to the solenoid operated directional valve.<br />

Type indication<br />

Features<br />

1. The circuit pressure can be controlled at<br />

two or three stages without vent<br />

connection.<br />

2. Concurrent use of the shock damping<br />

valve (refer to the section of the type<br />

number index “ZNS5”) can perform<br />

shockless, smooth pressure change.<br />

3. Adoption of the unequal type for the main<br />

plunger has realized stable operation.<br />

Three stage pressure relief valve<br />

Three stage<br />

pressure relief valve<br />

Nominal dimension<br />

<strong>10</strong>, 20, 30<br />

Connection method<br />

P<br />

C<br />

<br />

<br />

Gasket connection type<br />

Cartridge type<br />

Series number: <strong>10</strong><br />

Shape of pressure adjusting part<br />

2 = Thread adjustment (with cap)<br />

Highest adjustment pressure<br />

<strong>10</strong>0 9.8MPa (<strong>10</strong>0kgf/cm 2 )<br />

315 30.9MPa (315kgf/cm 2 )<br />

Vent port<br />

No symbol<br />

Without vent port (in the case of flange connection type<br />

and cartridge type)<br />

X =With vent port (in the case of gasket connection type)<br />

Drain system<br />

No symbol = Internal drain<br />

Y = External drain<br />

Spool type of solenoid operated directional valve<br />

05=<br />

08=<br />

14=<br />

a<br />

a<br />

a<br />

A B<br />

P T<br />

A B<br />

P T<br />

A B<br />

P T<br />

b<br />

b<br />

Design No.<br />

Shock damping valve provided or not<br />

No symbol = Without shock damping valve<br />

S = With shock damping valve<br />

Electric connection symbol<br />

Symbol<br />

B<br />

C<br />

CL<br />

Explanation<br />

With DIN connector<br />

With DIN large connector<br />

With DIN large connector with lamp<br />

Input voltage<br />

12<br />

24<br />

<br />

<br />

<strong>10</strong>0 <br />

200 <br />

12V<br />

24V<br />

<strong>10</strong>0V<br />

200V<br />

Type of hydraulic oil<br />

No symbol = Mineral based hydraulic oil<br />

V = Phosphate ester based hydraulic oil<br />

W = Fatty ester based hydraulic oil<br />

W1 = Water-glycol based hydraulic oil<br />

Input power supply<br />

A = Alternating current<br />

D = Direct current<br />

R = AC/DC conversion<br />

Input power supply<br />

A D R<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

* For details of voltage specifications, refer to “Solenoid<br />

specifications” of the solenoid operated directional valve “DE5”.<br />

* For other power supply, please contact us.<br />

Solenoid type<br />

W = Wet type<br />

(with standard emergency manual operation)<br />

2-27