<strong>GS5</strong>11Z Tech Sheet<br />

<strong>Balboa</strong> Instruments<br />

System PN <strong>54519</strong>-<strong>02</strong><br />

System Model # <strong>GS5</strong>-<strong>GS5</strong>11Z-<strong>RCA</strong>-<strong>3.0</strong><br />

Software Version # 43<br />

EPN # 2720<br />

Base PCBA - PN 54520-<strong>02</strong><br />

PCB <strong>GS5</strong>00Z - PN 22015 Rev B<br />

Base Panels<br />

VL401 (LCD Lite Duplex) – PN 54251<br />

VL4<strong>02</strong> (LCD Duplex Digital) – PN 54107<br />

VL403 (LED Lite Duplex) – PN 54104-01<br />

VL404 (LED Duplex Digital) – PN 51248<br />

Template used: 40599_M.pdf 04/16/2008<br />

<strong>54519</strong>-<strong>02</strong>_97_B.pdf 05/<strong>02</strong>/2008<br />

Page 1<br />

<strong>54519</strong>-<strong>02</strong>_97_B


System Revision History<br />

System PN EPN Date Requested By Changes Made<br />

<strong>54519</strong> 1843 08.<strong>02</strong>.2006 <strong>Balboa</strong> New system<br />

<strong>54519</strong>-01 2669 12.07.2007 <strong>Balboa</strong> Software update to v41<br />

<strong>54519</strong>-<strong>02</strong> 2720 <strong>02</strong>.21.2008 <strong>Balboa</strong> Software update to v43<br />

<strong>54519</strong>-<strong>02</strong> n/a 05.<strong>02</strong>.2008 <strong>Balboa</strong> Main PCB update to rev B<br />

Page 2<br />

<strong>54519</strong>-<strong>02</strong>_97_B


Basic System Features and Functions<br />

Power Requirements<br />

<br />

<br />

<br />

<br />

Requires PCB Rev B.<br />

<br />

<br />

System Outputs<br />

Setup 1 (As Manufactured)<br />

<br />

<br />

<br />

<br />

(Stereo)<br />

<br />

Optional Devices<br />

<br />

<br />

<br />

Additional Options<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

J1<br />

J2<br />

J10<br />

J1A<br />

J2A<br />

U4<br />

J71<br />

J19<br />

J18<br />

1<br />

J60<br />

J7 J8<br />

1 1<br />

1<br />

1<br />

J44<br />

1<br />

J12<br />

Page 3<br />

J22<br />

EXT RLY AUX F SEN A SEN B VAC<br />

J11<br />

1<br />

<strong>54519</strong>-<strong>02</strong>_97_B


C<br />

G<br />

Basic System Features and Functions<br />

Any time you change a DIP Switch, other than A1, you must reset Persistent<br />

Memory for your new DIP Switch Settings changes to take effect. If you do<br />

not reset Persistent Memory, your system may function improperly.<br />

To reset Persistent Memory:<br />

Power down by disconnecting power source from spa.<br />

Put a jumper across J43, covering both pins. (See illustration below)<br />

Power up by connecting power source to spa.<br />

Wait until “ ” is displayed on your panel.<br />

Power down again.<br />

Remove jumper from J43 (May also move to cover 1 pin only)<br />

Power up again.<br />

About Persistent Memory and Time of Day Retention:<br />

This system uses memory that doesn’t require a battery to store a variety of<br />

settings. What we refer to as Persistent Memory stores the filter settings,<br />

the set temperature, and the heat mode.<br />

Persistent Memory is not used for Time of Day. Only models with a<br />

Serial Deluxe panel installed (VS5xxDZ and <strong>GS5</strong>xxDZ) can display the<br />

time. However, during power loss to the spa, the system will lose the<br />

correct time, and reset to 12:00 PM when power is restored.<br />

Power Up Display Sequence<br />

Upon power up, you should see the following on the display:<br />

Three numbers in a row, which are the SSID (the System Software<br />

ID). The third display of these numbers is the Software Version,<br />

which should match the version of your system. For example, if these<br />

three numbers are , that is a VS511SZ at version 38.<br />

Displayed next is: “ ” (indicating the system is configured for<br />

a heater between 3 and 6 kW) or “ ” (indicating the system is<br />

configured for a heater effectively* between 1 and 3 kW).<br />

“ ” should appear for all VS models running at 240VAC.<br />

“ ” should appear for all VS models running at 120VAC, as well<br />

as all GS models. (*A heater which is rated at 4 kW at 240VAC will<br />

function as a 1 kW heater at 120VAC.)<br />

“ ” will appear to signal the start of Priming Mode.<br />

At this point, the power up sequence is complete. Refer to the Reference<br />

Card for the VS or GS System model of your spa for information about how<br />

the spa operates from this point on, including how to adjust the Time of<br />

Day if using a Serial Deluxe style panel.<br />

J43<br />

E.GND<br />

K6<br />

G C<br />

F4 FUSE .3A 250V<br />

J23<br />

K1<br />

W1<br />

SWITCHBANK<br />

T1A<br />

K3<br />

K2<br />

F2<br />

W4<br />

E.GND<br />

J50<br />

G C<br />

J6<br />

G C<br />

SWITCHBANK A<br />

F7<br />

J17/26<br />

S1 TST<br />

FUSE 20A 250V<br />

W7<br />

K8<br />

K9<br />

J43<br />

J2<br />

J1<br />

J46<br />

J60 J22<br />

J6 J7 J8<br />

S1 TST<br />

EXT.<br />

AUX. F<br />

RLY<br />

SEN. A SEN. B<br />

J47<br />

G C<br />

W2<br />

W3<br />

J1A<br />

J2A<br />

J29<br />

G C<br />

K5<br />

1 2 3<br />

U4 J12<br />

J20<br />

F1<br />

J10<br />

FUSE 3A 250V<br />

J18<br />

J13<br />

BALBOA INSTRUMENTS, INC. 2-SPD<br />

J44 VS500Z<br />

EXT RLY<br />

P/N 22972 REV D<br />

VAC<br />

MADE IN U.S.A<br />

COPYRIGHT 2005<br />

J43 on VS5xxZ and VS300 Series Main Board Shown.<br />

J43 on <strong>GS5</strong>xxZ Series is located in approximately the same position.<br />

J26<br />

J90<br />

J50<br />

LINE<br />

BLK AC<br />

W1<br />

K4<br />

K1<br />

VS100<br />

P/N 22964_B MADE IN U.S.A.<br />

© 2006<br />

PUMP<br />

T0.25A 250V<br />

<strong>Balboa</strong><br />

J58<br />

G C<br />

J23<br />

F2<br />

HEATER<br />

OZONE<br />

J29<br />

G C<br />

WHT AC<br />

K3<br />

J9<br />

K2<br />

K5<br />

SWITCHBANK A<br />

NEUTRAL<br />

J57<br />

TST RST<br />

J6 J43<br />

F4<br />

S1<br />

SWITCHBANK A<br />

TST RST<br />

J6 J43<br />

J43 on VS100/GS100 Series Main Board Shown.<br />

F5, F3A 250V<br />

J13 J12<br />

J7<br />

SEN. A<br />

J8<br />

SEN. B<br />

J18<br />

U4<br />

J20<br />

G C<br />

J1<br />

Page 4<br />

<strong>54519</strong>-<strong>02</strong>_97_B


Wiring Configuration and DIP Settings<br />

Setup 1 (As Manufactured)<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

(Stereo)<br />

<br />

<br />

<br />

<br />

<br />

HIPot Testing Note:<br />

Disconnect slip terminal with green<br />

wires from J90 prior to performing<br />

HiPot test. Failure to disconnect may<br />

cause a false failure of the test.<br />

Reconnect terminal to J90 after<br />

successful completion of HiPot test.<br />

No Blower in this Configuration<br />

J52<br />

J51<br />

F6, T30A 480V<br />

J25<br />

J32<br />

1<br />

TB1<br />

J50<br />

J47<br />

AV<br />

Audio G N Visual<br />

CIRC. PUMP<br />

Circ G N Pump<br />

F4, T0.2A 250V<br />

J29<br />

J23<br />

OZONE PUMP 1<br />

Ozone<br />

G N<br />

J58<br />

2-Spd 1-Spd P1<br />

G N<br />

K9<br />

T1<br />

K6<br />

K1<br />

X-2SP Con<br />

G N<br />

J17/26<br />

OPT. BLWR/PUMP 2<br />

J46<br />

K8<br />

10VAC<br />

J72<br />

F7<br />

F10A 250V<br />

K5<br />

C9<br />

J20<br />

F3A 250V<br />

F3<br />

J71<br />

Spa<br />

G N<br />

Light<br />

10VAC<br />

F1<br />

J13<br />

2<br />

3<br />

J28<br />

W2<br />

J1<br />

J2<br />

J1A<br />

J2A<br />

J26<br />

K3<br />

J57<br />

4<br />

<strong>Balboa</strong><br />

BALBOA INSTRUMENTS, IN<br />

<strong>GS5</strong>00Z<br />

COPYRIGHT 2007<br />

MADE IN U.S.A.<br />

P/N 22015_B<br />

W1<br />

Heater rated @ 240V<br />

J11 must be Jumpered<br />

HTR2 J101 HTR1 00<br />

<strong>3.0</strong> kW<br />

K4<br />

K2<br />

J90<br />

F2<br />

E.GND<br />

S1<br />

SWITCHBANK A<br />

J43<br />

J6<br />

TST<br />

J10<br />

J60<br />

EXT RLY<br />

J7<br />

J8<br />

1 1<br />

1<br />

1<br />

J22<br />

AUX F<br />

SEN A<br />

SEN B<br />

J44<br />

VAC<br />

U4<br />

1<br />

J11<br />

<strong>3.0</strong>kW<br />

J12<br />

1<br />

J19<br />

J18<br />

<strong>GS5</strong>1xZ mode<br />

1<br />

K2<br />

J6<br />

R B W<br />

G<br />

J2<br />

J4<br />

J7<br />

R B W G<br />

2-Spd P2<br />

J5 W12<br />

WARNING: Main Power to system should be turned OFF BEFORE adjusting DIP switches.<br />

WARNING: Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)<br />

SSID #<br />

100<br />

67<br />

43<br />

A1, Test Mode OFF<br />

A2, See Table 1<br />

A5, 2-speed P1<br />

Panel Button Assignments<br />

1=Pump 2 3=Temp<br />

2=Pump 1 4=Light<br />

<strong>3.0</strong>kW<br />

Heater<br />

J11<br />

A6, 50 Hz<br />

1<br />

A7, Mode changes allowed<br />

A8, Degrees C<br />

A9, Non-Circ Mode<br />

A10, See Table 1<br />

Panel Button Positions<br />

1<br />

1 2 3 4<br />

4 2<br />

Page 5<br />

<strong>GS5</strong>11Z<br />

Software<br />

J12<br />

3<br />

2<br />

J43<br />

Memory<br />

Reset<br />

3<br />

Wiring Color Key<br />

Neutral (Common) AC Connections<br />

Special AC Connections<br />

Line AC Connections<br />

10 Volt Connections<br />

Relay Control Wires<br />

Board Connector Key<br />

1 Typically Line voltage<br />

2 Typically Line voltage for 2-speed pumps<br />

3 Neutral (Common)<br />

4 Ground<br />

Note flat sides in connector<br />

<strong>54519</strong>-<strong>02</strong>_97_B


DIP Switches and Jumpers Definitions<br />

SSID 100 67 43<br />

DIP Switch Key<br />

A1 Test Mode (normally OFF)<br />

A2+A10 Control amp draw requirements (See Table 1)<br />

A3 “ON” position: use Mini Panel<br />

“OFF” position: use Digital Duplex or Light Duplex panel<br />

A4 Aux Freeze (must be OFF)<br />

A5+A9 Pump 1 speeds and Circ Modes:<br />

A5 A9 Circ Mode Pump 1 Speed<br />

OFF OFF Non-circ 2-speed<br />

ON OFF Circ "acts like Pump 1 low" (filters/polls/ect) 1-speed<br />

OFF ON 24 hours with 3°F shut-off 1-speed<br />

ON ON 24 hours with 3°F shut-off 2-speed<br />

A6 “ON” position: 50Hz operation<br />

“OFF” position: 60Hz operation<br />

A7 “ON” position: Standard mode only<br />

“OFF” position: Std/Ecn/Sleep mode changes allowed<br />

A8 “ON” position: temperature is displayed in degrees Celsius<br />

“OFF” position: temperature is displayed in degrees Fahrenheit<br />

Note: Panel layout is always Pump 2, Pump 1, Temp, Light<br />

Base Model <strong>GS5</strong>11Z<br />

Table 1 # of Hi-Speed<br />

Pumps/Blower<br />

Before Heat Disabled<br />

A2 A10<br />

OFF OFF 0<br />

ON OFF 1<br />

OFF ON 2<br />

ON ON 3<br />

Alert:<br />

2-speed Pump 2 is required,<br />

connect to Expander board.<br />

This system is not compatible with<br />

3-phase power input. Use <strong>GS5</strong>20Z<br />

for 3-phase power.<br />

Jumper Key<br />

J11 If using 3kW or higher wattage heater, jumper can be set in either position, but may perform better on Pins 1 and 2.<br />

If using 2.5kW or lower wattage heater, jumper must be set on 1 Pin only.<br />

J12 Factory set. DO NOT MOVE.<br />

Jumper must be on Pins 1 and 2 for <strong>GS5</strong>1xZ/<strong>GS5</strong>2xZ/<strong>GS5</strong>xxSZ/<strong>GS5</strong>xxDZ software.<br />

Jumper must be on Pins 2 and 3 for <strong>GS5</strong>0xZ software.<br />

J43 When jumper is placed on 2 pins during power-up, system will reset persistent memory.<br />

Leave on 1 pin only to enable persistent memory feature.<br />

WARNING:<br />

Setting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.<br />

Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.<br />

Contact <strong>Balboa</strong> if you require additional configuration pages added to this tech sheet.<br />

Panel Button Positions<br />

A3: OFF<br />

1 2 3 4<br />

1<br />

4 2<br />

3<br />

A3:ON 1<br />

2 3 4<br />

Panel Button Assignments<br />

1=Pump 2<br />

2=Pump 1<br />

3=Temp<br />

4=Light<br />

<br />

<strong>54519</strong>-<strong>02</strong>_97_B


AS MANUFACTURED<br />

L1<br />

N1<br />

Electrical Service Configuration Options<br />

Systems with PCB Rev B Only<br />

AV<br />

F7<br />

F1<br />

J13<br />

J50<br />

J29<br />

J23<br />

K6 K1<br />

OZONE PUMP 1<br />

K9<br />

F10A 250V<br />

J52 J51<br />

F6, T30A 480V<br />

F3A 250V<br />

G N<br />

J46<br />

CIRC. PUMP<br />

K8<br />

K5 J20<br />

J25<br />

G N<br />

C9<br />

G N<br />

J32<br />

(1 x 16 Amp or 1 x 32 Amp)<br />

F3<br />

TB1<br />

10VAC<br />

J17/26 J72<br />

1<br />

3 Wires (1 Line + 1 Neutral + 1 Protective Earth)<br />

F4, T0.2A 250V<br />

OPT. BLWR/PUMP 2<br />

J71<br />

T1<br />

J58<br />

2<br />

3<br />

4<br />

J57<br />

<strong>Balboa</strong><br />

BALBOA INSTRUMENTS, INC.<br />

<strong>GS5</strong>00Z<br />

COPYRIGHT 2007<br />

Pb<br />

MADE IN U.S.A.<br />

P/N 22015_B<br />

W1<br />

J47<br />

J28<br />

J26<br />

G N<br />

HTR2 J101 HTR1 00<br />

W2<br />

G N<br />

K3<br />

K4<br />

K2<br />

J90<br />

Single Service, TN and TT Electrical Systems<br />

J1A<br />

J1<br />

This option is configured J2 and shipped as the default.<br />

E.GND<br />

G N<br />

Protective Earth wire (Green/Yellow) must be connected<br />

to system ground terminal as marked.<br />

J2A<br />

All equipment (pumps, blower, and heater) runs on<br />

1<br />

J18<br />

service line L1.<br />

J43 J10<br />

U4<br />

F2<br />

J19<br />

S1<br />

J12<br />

J60<br />

J7 J8 J44<br />

J6<br />

1 1<br />

1<br />

1 1<br />

For 1 x 16 Amp Service:<br />

TST<br />

1<br />

SWITCHBANK A<br />

EXT RLY AUX F SEN A SEN B VAC J11<br />

DIP Switch A10 must be ON.<br />

Systems using only 1 DIP switch (A10) for heat disable:<br />

J22<br />

For 1 x 32 Amp Service:<br />

Set DIP Switch A10 such that total system amperage<br />

draw never exceeds rated service input.<br />

Systems using multiple DIP switches for heat disable:<br />

Refer to system Hot Sheet DIP Switch Definition page<br />

and set the switches shown in Table 1 such that total<br />

system amperage draw never exceeds rated service input.<br />

10VAC<br />

OPTIONAL<br />

L2<br />

N2<br />

L1<br />

N1<br />

J52<br />

J51<br />

F6, T30A 480V<br />

J57<br />

J25<br />

J32<br />

1<br />

2<br />

3<br />

4<br />

<strong>Balboa</strong><br />

BALBOA INSTRUMENTS, INC.<br />

<strong>GS5</strong>00Z<br />

COPYRIGHT 2007<br />

MADE IN U.S.A.<br />

P/N 22015_B<br />

Pb<br />

TB1<br />

W1<br />

J50<br />

J47<br />

G<br />

G<br />

N<br />

N<br />

AV<br />

CIRC. PUMP<br />

F4, T0.2A 250V<br />

J28<br />

J26<br />

HTR2 J101 HTR1 00<br />

J29<br />

J23<br />

OZONE PUMP 1<br />

G N<br />

W2<br />

J58<br />

G N<br />

K3<br />

K4<br />

K2<br />

K9<br />

T1<br />

J90<br />

K6<br />

K1<br />

J46<br />

Dual Service, TN<br />

K8<br />

and K5TT J20Electrical Systems<br />

C9<br />

G N<br />

F3<br />

10VAC<br />

5 Wires (2 J17/26Lines J72+ 2 Neutrals + 1 Protective Earth)<br />

OPT. BLWR/PUMP 2<br />

J71<br />

J1<br />

J1A<br />

J2A<br />

The heater runs on J2 service line L1, while all other<br />

E.GND<br />

G N<br />

(2 x 16 Amp)<br />

J18<br />

J43 J10<br />

U4<br />

Completely remove the white wire from J26 and J32.<br />

F2<br />

J19<br />

S1<br />

Note: J32 and J25 are electrically<br />

J12<br />

identical. The white<br />

J60<br />

J7 J8 J44<br />

J6<br />

1 1<br />

1<br />

1 1<br />

wire may be attached to either terminal before removal.<br />

TST<br />

1<br />

SWITCHBANK A<br />

EXT RLY AUX F SEN A SEN B VAC J11<br />

J22<br />

F7<br />

F10A 250V<br />

F3A 250V<br />

Protective Earth wire (Green/Yellow) must be connected<br />

to system ground terminal as marked.<br />

equipment, such as pumps and blowers, run on<br />

service line L2.<br />

10VAC<br />

F1<br />

J13<br />

1<br />

Systems using only 1 DIP switch (A10) for heat disable:<br />

DIP Switch A10 must be OFF.<br />

Systems using multiple DIP switches for heat disable:<br />

Refer to system Hot Sheet DIP Switch Definition page<br />

and set both switches shown in Table 1 to ON positions.<br />

Page 7<br />

<strong>54519</strong>-<strong>02</strong>_97_B


AS MANUFACTURED<br />

L1<br />

L2<br />

Electrical Service Configuration Options<br />

Systems with PCB Rev B Only<br />

AV<br />

J50<br />

J29<br />

OZONE<br />

J23<br />

PUMP K9<br />

K6 K1<br />

J52 J51<br />

F6, T30A 480V<br />

G N<br />

1<br />

J57<br />

J25<br />

J32<br />

1<br />

2<br />

3<br />

4<br />

<strong>Balboa</strong><br />

BALBOA INSTRUMENTS, INC.<br />

<strong>GS5</strong>00Z<br />

COPYRIGHT 2007<br />

MADE IN U.S.A.<br />

P/N 22015_B<br />

Pb<br />

TB1<br />

W1<br />

J47<br />

G<br />

N<br />

CIRC. PUMP<br />

F4, T0.2A 250V<br />

J28<br />

J26<br />

G N<br />

HTR2 J101 HTR1 00<br />

W2<br />

J58<br />

G N<br />

K3<br />

K4<br />

K2<br />

J90<br />

J46<br />

K8<br />

K5 J20<br />

C9<br />

G N<br />

Line - Line voltage is 230VAC (1 x 16 Amp or 1 x 32 Amp)<br />

F3<br />

10VAC<br />

3 Wires (2 J17/26Lines J72 + 1 Protective Earth)<br />

OPT. BLWR/PUMP 2<br />

J71<br />

T1<br />

J1<br />

J1A<br />

J2A<br />

J2<br />

All equipment (pumps, blower, and heater) runs on<br />

1<br />

J18<br />

J43 J10<br />

Systems using only 1 DIP switch (A10) for heat disable:<br />

U4<br />

E.GND<br />

G N<br />

F2<br />

S1<br />

J12<br />

DIP Switch A10 J60 must J7 be J8 ON.<br />

J44<br />

J6<br />

1 1<br />

1<br />

1 1<br />

J22<br />

F7<br />

F10A 250V<br />

F3A 250V<br />

Single Service, IT Electrical System (No Neutral)<br />

Protective Earth wire (Green/Yellow) must be connected<br />

to system ground terminal as marked.<br />

service line L1 with L2 acting as the return.<br />

For 1 x 16 Amp Service:<br />

For 1 x 32 Amp Service:<br />

TST<br />

1<br />

SWITCHBANK A<br />

EXT RLY AUX F SEN A SEN B VAC J11<br />

Set DIP Switch A10 such that total system amperage<br />

draw never exceeds rated service input.<br />

Systems using multiple DIP switches for heat disable:<br />

Refer to system Hot Sheet DIP Switch Definition page<br />

and set the switches shown in Table 1 such that total<br />

system amperage draw never exceeds rated service input.<br />

10VAC<br />

J19<br />

F1<br />

J13<br />

OPTIONAL<br />

L1<br />

L2<br />

L3<br />

J52<br />

J51<br />

F6, T30A 480V<br />

J57<br />

J25<br />

J32<br />

1<br />

2<br />

3<br />

4<br />

<strong>Balboa</strong><br />

BALBOA INSTRUMENTS, INC.<br />

<strong>GS5</strong>00Z<br />

COPYRIGHT 2007<br />

Pb<br />

MADE IN U.S.A.<br />

P/N 22015_B<br />

TB1<br />

W1<br />

J50<br />

J47<br />

G<br />

G<br />

N<br />

N<br />

AV<br />

CIRC. PUMP<br />

J28<br />

Line 3 - Cap (Insulate) end,<br />

Do not connect.<br />

F4, T0.2A 250V<br />

J26<br />

HTR2 J101 HTR1 00<br />

J29<br />

J23<br />

OZONE PUMP 1<br />

G N<br />

W2<br />

J58<br />

G N<br />

K3<br />

K4<br />

K2<br />

K9<br />

T1<br />

J90<br />

K6<br />

K1<br />

J46<br />

K8<br />

K5 J20<br />

C9<br />

G N<br />

Line - Line voltage is 230VAC<br />

F3<br />

10VAC<br />

4 Wires (3 J17/26Lines J72 + 1 Protective Earth)<br />

OPT. BLWR/PUMP 2<br />

J71<br />

J1<br />

J1A<br />

J2A<br />

J2<br />

All equipment (pumps, blower, and heater) runs on<br />

1<br />

J18<br />

J43 J10<br />

Systems using only 1 DIP switch (A10) for heat disable:<br />

U4<br />

E.GND<br />

G N<br />

F2<br />

S1<br />

J12<br />

DIP Switch A10 J60 must J7 be J8 ON.<br />

J44<br />

J6<br />

1 1<br />

1<br />

1 1<br />

J22<br />

F7<br />

F10A 250V<br />

F3A 250V<br />

3-Phase Service, IT Electrical System (No Neutral)<br />

Protective Earth wire (Green/Yellow) must be connected<br />

to system ground terminal as marked.<br />

service line L1 with L2 acting as the return.<br />

For 1 x 16 Amp Service:<br />

For 1 x 32 Amp Service:<br />

TST<br />

1<br />

SWITCHBANK A<br />

EXT RLY AUX F SEN A SEN B VAC J11<br />

Set DIP Switch A10 such that total system amperage<br />

draw never exceeds rated service input.<br />

Systems using multiple DIP switches for heat disable:<br />

Refer to system Hot Sheet DIP Switch Definition page<br />

and set the switches shown in Table 1 such that total<br />

system amperage draw never exceeds rated service input.<br />

10VAC<br />

J19<br />

F1<br />

J13<br />

NOTE:<br />

Not all <strong>GS5</strong>xxZ systems can support 3-Phase.<br />

3-Phase requires System PCB Rev B.<br />

If using an expansion board, the board must have fuse-protection.<br />

Page 8<br />

<strong>54519</strong>-<strong>02</strong>_97_B


Ozone Connections<br />

Note: A special tool is required to remove the pins from the connector body once they are snapped in<br />

place. Check with your <strong>Balboa</strong> Account Manager for information on purchasing a pin-removal tool.<br />

<strong>Balboa</strong> Ozone connector configuration for 230VAC 50Hz:<br />

Black or Brown Line Conductor<br />

Empty<br />

White or Blue Neutral Conductor<br />

Empty<br />

L<br />

N<br />

Flat sides of sockets as shown<br />

J52<br />

J51 F6, T30A 480V<br />

J25<br />

J32<br />

TB1<br />

1<br />

J50<br />

J47<br />

AV<br />

Audio G W Visual B R<br />

CIRC. PUMP<br />

Circ G W Pump B R<br />

F4, T0.2A 250V<br />

J29<br />

OZONE PUMP 1<br />

J90<br />

J58<br />

J23<br />

G W B R<br />

2-Spd P1<br />

Line - Black or Brown conductor<br />

Not used<br />

Neutral - White or Blue conducto<br />

Not used<br />

2<br />

J28<br />

W2<br />

J57<br />

Page 9<br />

<strong>54519</strong>-<strong>02</strong>_97_B


Duplex Panel Configurations<br />

Heat<br />

Jets<br />

Jets<br />

Temp<br />

Light<br />

VL401 (LCD Lite Digital)<br />

PN 54251 with Overlay PN 11671<br />

Connects to Main Board terminal J1 or J2<br />

Jets 2<br />

Heat<br />

Set<br />

Light<br />

Jets 1<br />

SETUP 1<br />

VL4<strong>02</strong> (LCD Duplex Digital)<br />

PN 54107 with Overlay PN 10764<br />

Connects to Main Board terminal J1 or J2<br />

Not compatible with some configurations; not recommended for new designs<br />

Heat<br />

Jets Jets Temp Light<br />

VL401 (LCD Lite Digital)<br />

PN 54104-01 with Overlay PN 10752<br />

Connects to Main Board terminal J1 or J2<br />

Jets 2<br />

Set<br />

Jets 1<br />

Light<br />

VL4<strong>02</strong> (LCD Duplex Digital)<br />

PN 51248 with Overlay PN 10418<br />

Connects to Main Board terminal J1 or J2<br />

Not compatible with some configurations; not recommended for new designs<br />

Page 10<br />