<strong>Report</strong> No: T110218402-RT<br />

Reference No: 90522403-RT Date of Issue: March 18, 2011<br />

8. APPLICABLE LIMITS AND TEST RESULTS<br />

8.1 EQUIVALENT ISOTROPIC RADIATED POWER<br />

LIMIT<br />

EN 300 328 Clause 4.3.1<br />

The equivalent isotropic radiated power shall be equal to or less than -10 dBW (100<br />

mW) e.i.r.p. This limit shall apply for any combination of power level and intended<br />

antenna assembly.<br />

TEST EQUIPMENTS<br />

Name of<br />

Equipment<br />

Manufacturer Model Serial Number Calibration Due<br />

Temp./Humidity<br />

Chamber<br />

K.SON THS-M1 242 AUG. 11, 2011<br />

Power Meter Anritsu ML2487A 6K00003888 MAY 11, 2011<br />

TEST SETUP<br />

Temperature Chamber<br />

Power Meter<br />

EUT<br />

Variable power supply<br />

TEST PROCEDURE<br />

1. .Please refer to ETSI EN 300 328 (V1.6.1) clause 5.3 for the test conditions.<br />

2. Please refer to ETSI EN 300 328 (V1.7.1) clause 5.7.2.2 for the measurement<br />

method.<br />

TEST RESULTS<br />

No non-compliance noted<br />