Testing Report - RhinoCo Technology
Testing Report - RhinoCo Technology
Testing Report - RhinoCo Technology
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Report</strong> No: T110218402-RT<br />
Reference No: 90522403-RT Date of Issue: March 18, 2011<br />
Product Name<br />
N+ High Power Gigabit Broadband<br />
Router-All Broadbands<br />
Test Date 2011/03/11<br />
Model GR290n Test By John Chen<br />
Test Mode IEEE 802.11n HT20 / TX (CH High) TEMP& Humidity 23.6℃, 61%<br />
Frequency<br />
(MHz)<br />
Reading<br />
(dBμV)<br />
Antenna<br />
Polarization<br />
(V/H)<br />
Emission<br />
level<br />
(dBm)<br />
Limit<br />
(dBm)<br />
Margin<br />
(dB)<br />
Correction<br />
Factor<br />
(dB)<br />
125.00 41.32 H -71.27 -57.00 -14.27 -3.44<br />
249.99 43.95 H -68.24 -57.00 -11.24 -3.04<br />
374.98 33.26 H -75.93 -57.00 -18.93 -0.04<br />
500.03 35.85 H -70.43 -57.00 -13.43 2.87<br />
625.00 33.17 H -70.40 -57.00 -13.40 5.58<br />
750.01 32.02 H -70.00 -57.00 -13.00 7.13<br />
125.00 43.74 V -64.02 -57.00 -7.02 1.39<br />
250.03 41.26 V -68.83 -57.00 -11.83 -0.94<br />
375.02 33.52 V -74.25 -57.00 -17.25 1.38<br />
500.00 36.85 V -66.65 -57.00 -9.65 5.65<br />
624.98 31.41 V -68.82 -57.00 -11.82 8.92<br />
750.00 31.05 V -69.81 -57.00 -12.81 8.29<br />
Remark:<br />
1. The emission behaviour belongs to narrowband spurious emission.<br />
2. According to technical experiences, all spurious emissions at all channels are almost the<br />
same below 1GHz, so that the channel low was chosen as representative for the test.<br />
Page 33