Testing Report - RhinoCo Technology
Testing Report - RhinoCo Technology
Testing Report - RhinoCo Technology
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Report</strong> No: T110218402-RT<br />
Reference No: 90522403-RT Date of Issue: March 18, 2011<br />
Product Name<br />
N+ High Power Gigabit Broadband<br />
Router-All Broadbands<br />
Test Date 2011/03/11<br />
Model GR290n Test By John Chen<br />
Test Mode IEEE 802. 11n HT20 / TX (CH High) TEMP& Humidity 23.6℃, 61%<br />
Frequency<br />
(MHz)<br />
Reading<br />
(dBμV)<br />
Antenna<br />
Polarization<br />
(V/H)<br />
Emission<br />
level<br />
(dBm)<br />
Limit<br />
(dBm)<br />
Margin<br />
(dB)<br />
Correction<br />
Factor<br />
(dB)<br />
1499.98 45.39 H -66.05 -30.00 -36.05 -2.29<br />
4944.02 43.52 H -58.82 -30.00 -28.82 6.81<br />
1500.01 43.89 V -67.58 -30.00 -37.58 -2.32<br />
4944.00 50.36 V -53.32 -30.00 -23.32 5.47<br />
Remark:<br />
1. The emission behaviour belongs to narrowband spurious emission.<br />
2. Measurements above show only up to 6 maximum emissions noted, or would be lesser if<br />
no specific emissions from the EUT are recorded (i.e.: margin>20dB from the applicable<br />
limit) and considered that's already beyond the background noise floor.<br />