<strong>Report</strong> No: T110218402-RT<br />

Reference No: 90522403-RT Date of Issue: March 18, 2011<br />

Product Name<br />

N+ High Power Gigabit Broadband<br />

Router-All Broadbands<br />

Test Date 2011/03/11<br />

Model GR290n Test By John Chen<br />

Test Mode IEEE 802. 11n HT20 / TX (CH High) TEMP& Humidity 23.6℃, 61%<br />

Frequency<br />

(MHz)<br />

Reading<br />

(dBμV)<br />

Antenna<br />

Polarization<br />

(V/H)<br />

Emission<br />

level<br />

(dBm)<br />

Limit<br />

(dBm)<br />

Margin<br />

(dB)<br />

Correction<br />

Factor<br />

(dB)<br />

1499.98 45.39 H -66.05 -30.00 -36.05 -2.29<br />

4944.02 43.52 H -58.82 -30.00 -28.82 6.81<br />

1500.01 43.89 V -67.58 -30.00 -37.58 -2.32<br />

4944.00 50.36 V -53.32 -30.00 -23.32 5.47<br />

Remark:<br />

1. The emission behaviour belongs to narrowband spurious emission.<br />

2. Measurements above show only up to 6 maximum emissions noted, or would be lesser if<br />

no specific emissions from the EUT are recorded (i.e.: margin>20dB from the applicable<br />

limit) and considered that's already beyond the background noise floor.<br />

Page 41