Testing Report - RhinoCo Technology
Testing Report - RhinoCo Technology
Testing Report - RhinoCo Technology
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Report</strong> No: T110218402-RT<br />
Reference No: 90522403-RT Date of Issue: March 18, 2011<br />
Product Name<br />
N+ High Power Gigabit Broadband<br />
Router-All Broadbands<br />
Test Date 2011/03/11<br />
Model GR290n Test By John Chen<br />
Test Mode IEEE 802. 11n HT40 / TX (CH High) TEMP& Humidity 23.6℃, 61%<br />
Frequency<br />
(MHz)<br />
Reading<br />
(dBμV)<br />
Antenna<br />
Polarization<br />
(V/H)<br />
Emission<br />
level<br />
(dBm)<br />
Limit<br />
(dBm)<br />
Margin<br />
(dB)<br />
Correction<br />
Factor<br />
(dB)<br />
1500.04 44.04 H -67.34 -30.00 -37.34 -2.23<br />
4923.97 43.93 H -58.48 -30.00 -28.48 6.74<br />
1499.98 43.06 V -68.48 -30.00 -38.48 -2.39<br />
4924.02 50.33 V -53.41 -30.00 -23.41 5.41<br />
Remark:<br />
1. The emission behaviour belongs to narrowband spurious emission.<br />
2. Measurements above show only up to 6 maximum emissions noted, or would be lesser if<br />
no specific emissions from the EUT are recorded (i.e.: margin>20dB from the applicable<br />
limit) and considered that's already beyond the background noise floor.<br />
Page 43