11.11.2014 Views

Testing Report - RhinoCo Technology

Testing Report - RhinoCo Technology

Testing Report - RhinoCo Technology

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Report</strong> No: T110218402-RT<br />

Reference No: 90522403-RT Date of Issue: March 18, 2011<br />

Product Name<br />

N+ High Power Gigabit Broadband<br />

Router-All Broadbands<br />

Test Date 2011/03/11<br />

Model GR290n Test By John Chen<br />

Test Mode IEEE 802. 11n HT40 / TX (CH High) TEMP& Humidity 23.6℃, 61%<br />

Frequency<br />

(MHz)<br />

Reading<br />

(dBμV)<br />

Antenna<br />

Polarization<br />

(V/H)<br />

Emission<br />

level<br />

(dBm)<br />

Limit<br />

(dBm)<br />

Margin<br />

(dB)<br />

Correction<br />

Factor<br />

(dB)<br />

1500.04 44.04 H -67.34 -30.00 -37.34 -2.23<br />

4923.97 43.93 H -58.48 -30.00 -28.48 6.74<br />

1499.98 43.06 V -68.48 -30.00 -38.48 -2.39<br />

4924.02 50.33 V -53.41 -30.00 -23.41 5.41<br />

Remark:<br />

1. The emission behaviour belongs to narrowband spurious emission.<br />

2. Measurements above show only up to 6 maximum emissions noted, or would be lesser if<br />

no specific emissions from the EUT are recorded (i.e.: margin>20dB from the applicable<br />

limit) and considered that's already beyond the background noise floor.<br />