ERV(Energy Recovery Ventilator) SYSTEM<br />

2009 Samsung DVM Air Conditioners<br />

<br />

94 95<br />

<br />

Compact Size & Flexible Installation<br />

Compact and Slim in Size by High Efficiency Diamond Element.<br />

Line-up<br />

RHF025EE<br />

250<br />

RHF035EE<br />

350<br />

RHF050EE<br />

500<br />

RHF080EE<br />

800<br />

RHF100EE<br />

1,000<br />

Ex.) Model No. RHF-035~050<br />

<strong>Specification</strong> | ERV System<br />

Model<br />

RHF025EE<br />

RHF035EE<br />

RHF050EE<br />

RHF080EE<br />

RHF100EE<br />

Voltage<br />

V<br />

220~240<br />

220~240<br />

220~240<br />

220~240<br />

220~240<br />

Frequency<br />

Hz<br />

50/60<br />

50/60<br />

50/60<br />

50/60<br />

50/60<br />

Withstand Voltage<br />

-<br />

AC1500V, 1min<br />

AC1500V, 1min<br />

AC1500V, 1min<br />

AC1500V, 1min<br />

AC1500V, 1min<br />

Insulation Resistance<br />

-<br />

30MG<br />

30MG<br />

30MG<br />

30MG<br />

30MG<br />

Air Volume<br />

m 3 /hr<br />

250<br />

350<br />

500<br />

800<br />

1,000<br />

Energy Saving Operation (Auto Mode)<br />

It automatically changes operation mode depending on temperature difference between indoor<br />

and outdoor to save energy.<br />

Damper<br />

Extreme Climates (Winter & Summer)<br />

When temperature and humidity level difference between indoor and<br />

outdoor is big, it operates as ERV.<br />

EA<br />

OA<br />

Element<br />

RA<br />

SA<br />

External Static Pressure<br />

Leakage Rate<br />

Power Input<br />

Current<br />

Temperature Exchange<br />

Efficiency<br />

Effective Enthalpy<br />

Cooling<br />

Heating<br />

Cooling<br />

Pa<br />

%<br />

W<br />

A<br />

%<br />

%<br />

%<br />

110<br />

10<br />

115<br />

0.7<br />

70<br />

70<br />

50<br />

155<br />

10<br />

115<br />

0.7<br />

70<br />

70<br />

50<br />

165<br />

10<br />

175<br />

1.1<br />

70<br />

70<br />

50<br />

155<br />

10<br />

330<br />

2.1<br />

70<br />

70<br />

50<br />

155<br />

10<br />

450<br />

2.9<br />

70<br />

70<br />

50<br />

Exchange Efficiency<br />

Heating<br />

%<br />

70<br />

70<br />

70<br />

70<br />

70<br />

Mild Climates (Spring & Fall)<br />

When temperature and humidity level difference between indoor and<br />

outdoor is small, it operates as conventional ventilation fan.<br />

EA<br />

OA<br />

Element<br />

Damper<br />

RA<br />

SA<br />

Sound Level (Turbo/Low)<br />

Dust Collection Method<br />

Net Dimensions(WxHxD)<br />

Gross Dimensions (WxHxD)<br />

Weight (Net/Gross)<br />

dB(A)<br />

-<br />

mm<br />

mm<br />

kg<br />

27/22<br />

High efficiency filter(PP)<br />

600X350X660<br />

760X400X807<br />

25.5/30<br />

31/24<br />

High efficiency filter(PP)<br />

1,012X270X1,000<br />

1,299X337X1,183<br />

42.5/53.5<br />

32/25<br />

High efficiency filter(PP)<br />

1,012X270X1,000<br />

1,299X337X1,183<br />

42.5/53.5<br />

33/29<br />

High efficiency filter(PP)<br />

1,220X340X1,135<br />

1,475X 440 X1,330<br />

67/75.5<br />

37/32<br />

High efficiency filter(PP)<br />

1,220X340X1,135<br />

1,475X440X1,330<br />

67/75.5<br />

Duct Diameter<br />

Ø,mm<br />

150<br />

200<br />

200<br />

250<br />

250