CONTROL SYSTEMS - Integrated Management System<br />
2009 Samsung DVM Air Conditioners<br />
<br />
102 103<br />
<br />
DMS System<br />
Web Server Function<br />
• Built-in web server.<br />
• Multiple upper-layer control access with prioritized management.<br />
• Remote access control with the static IP address.<br />
Internet<br />
Centralized<br />
Controller<br />
Interface Module<br />
Anytime, Anywhere<br />
Control<br />
DMS<br />
Schedule Control Function<br />
08:00 AM On 10:00 PM Off<br />
• Up to 256 schedule settings.<br />
• Weekly, Daily or 1-Day schedule control.<br />
Centralized<br />
Controller<br />
Interface Module<br />
• Exception date setting.<br />
Cooling<br />
Schedule Setup<br />
History Management<br />
Rapid Service Response<br />
Interface Module<br />
• Easy service and management with error history.<br />
• Occurrence date, error details, current state.<br />
SIM<br />
Watt Hour<br />
Meter<br />
Service<br />
Error History Monitoring<br />
Main Features<br />
Enhanced central management<br />
Easy Control & Monitoring<br />
Power Distribution System<br />
• Power distribution to up to 256 indoor units.<br />
• Data query for watt-hour, use time and use ratio.<br />
• File save in Microsoft Excel format.<br />
• 93 days worth of power distribution data storage.<br />
Indoor unit operation state<br />
5 th Floor<br />
4 th Floor<br />
140<br />
kWh<br />
610<br />
kWh<br />
• Operation mode lock<br />
• Temperature limit setting<br />
• Wireless / wired remote control restriction<br />
• Individual/Group control and monitoring of up to 256 indoor units.<br />
• Operation mode, temperature setting, airflow direction and<br />
fan speed.<br />
• Easy multiple/full indoor unit selection.<br />
• Full room temperature display.<br />
• Error history query based on date.<br />
1. Operation data accumulation and<br />
power distribution<br />
2.Data extract - Excel format<br />
3 rd Floor<br />
2 nd Floor<br />
1 st Floor<br />
460<br />
kWh<br />
360<br />
kWh<br />
180<br />
kWh<br />
External Contact Interface<br />
• Full indoor unit control with simple contact<br />
input. (Emergency/Lock)<br />
Building Control System<br />
Operation Restriction<br />
• State output (Operation/Error) for synchronous<br />
control.<br />
Fire Control System<br />
Error Status Indicator