Manual switch<br />

The node, which receives the R-APS (MS), forwards it to the adjacent nodes. If the receiving node is<br />

already in the Idle or Pending state, it unblocks the non-failed port and stops transmitting R-APS<br />

messages. Only one MS can exist in the topology at any time. An MS condition has to be <strong>manual</strong>ly<br />

cleared with the no command.<br />

NOTE<br />

If any ERN is in an FS state or in a protected state through an SF event and an operator tries to<br />

configure an MS, the ERN will reject the request.<br />

When a <strong>manual</strong> switch is cleared by an operator on the same node on which the MS is configured,<br />

the node keeps the port in a blocking state, sends out a R-APS (NR) to the adjacent node, and<br />

starts the guard timer. Other nodes that receive the R-APS (NR) forward the message. When the<br />

RPL owner receives this message, then the RPL owner starts the WTR timer. When the WTR timer<br />

expires, the RPL owner sends out a R-APS (NR, RB), blocks the RPL, and flushes the FDB. Other<br />

nodes in the topology that receive the R-APS (NR, RB) unblock any non-failed port and flush the<br />

FDB.<br />