REVERSING LOOP MODULES MX7, MX7/3 Page 1<br />
EDITION:<br />
2003 02 15<br />
Operating in struc tions<br />
Re ver sing loop mo du les MX7, MX7/3<br />
current version (from March 2002)
3 1<br />
4 2<br />
3 1<br />
4 2<br />
Page 2<br />
REVERSING LOOP MODULES MX7, MX7/3<br />
1. Allgemeines<br />
By using a MX7 and isolating a sec ti on of track with gaps in both rails on either side<br />
every reversing loop configuration (also turntables) can be wired and used without<br />
any pro blems. The changing of po la ri ty in the reversing loop section is done very<br />
quickly (within some microsecs) when the train is cros sing the gap and cau ses a<br />
short circuit. The train con ti nu es running without any visible influence from the re -<br />
versing loop; and it is al ways ful ly controllable by the cab.<br />
The potentiometer allows to ad just the cur rent treshhold, which cau ses the auto -<br />
matic change of polarity (and which is also the in di ca ti on for a real overcurrent con -<br />
dition, which is assumed, when the current goes beyond the tres hold also after<br />
some po la ri ty chan ges). In the lat ter case the out put LED is flashing.<br />
Nor mal ly it is not necessary to modify the ori gi nal adjustment; for lar ge scales so -<br />
me ti mes it is necessary to make a turn to the right side.<br />
Triple reversing loop mo du le MX7/3:<br />
This device con tains three ti mes the circuitry of the MX7. It is used for cases, when<br />
not enough spa ce for a re ver sing loop section containing a full lenght of a whole<br />
train is avai la ble. Then threee both-rail-gapped sec tions (instead of one) should be<br />
built in such a way, that the pro ba bi li ty of crossing all four gaps at the same time is<br />
very low. The usual way is to make one sec ti on in the lenght of a loco (or a con sist of<br />
lo cos), and adjacent (on both sides) a short sec ti on (in the length of a bo gie).<br />
2. Specifications<br />
3. Track sections and con nec tions to MX7<br />
Most simple way of use:<br />
Jumper in right position (ex works)<br />
C O M M A N D S T A T I O N M X 1 - B A C K V I E W<br />
RS.232<br />
CAN CAN<br />
TRAFO<br />
~ ~<br />
Track outputs ....................................................... 3 A (Over cur rent pro tec ti on)<br />
Track input (from the<br />
command station)<br />
Grund and pos. voltage,<br />
to be connected with the<br />
command station in order<br />
to reduce the voltage drop<br />
in the reversing loop track<br />
section; obligatory in<br />
certain cases.<br />
Adjusting the treshold<br />
for polarity change<br />
(between about 2 - 4 A)<br />
Jumper<br />
right position (ex works) - ouputs supplied from track input<br />
left position - outputs suppled from ground and pos. voltage<br />
+<br />
GROUND<br />
Jumper<br />
open (ex works); jumper should be used, if MX7 is used<br />
after MX9, and MX9 shows wrong<br />
occupancy state.<br />
Outputs for 3 track sections;<br />
LEDs showing current<br />
polarity (red/green).<br />
Contineous flashing means<br />
short circuit because of<br />
high current or bridging<br />
all track isolations<br />
simultaneously.<br />
Flashing LED shows operation<br />
of the module.<br />
With addtional connection<br />
of ground and pos. voltage:<br />
C O M M A N D S T A T I O N M X 1 - B A C K V I E W<br />
RS.232<br />
CAN<br />
CAN<br />
TRAFO<br />
~ ~<br />
Jumper in left position
REVERSING LOOP MODULES MX7, MX7/3 Page 3<br />
MX7 in a track triangle:<br />
5.<br />
If there is only little room<br />
between the turnouts,<br />
it must be avoided, that<br />
both track isolations<br />
are bridged simultaneoulsy<br />
MX7/3 in a track triangle:<br />
only one of the four track isolations<br />
must remain free at<br />
any time; if the distances of the<br />
4 track isolations are arranged<br />
cleverly, this is the case always.<br />
5 cm<br />
5 cm<br />
(distance of car wheels)<br />
40 cm<br />
max. lenght of loco(s)<br />
RS.232<br />
MX7 used after track section module MX9:<br />
CAN<br />
CAN<br />
3 1<br />
4 2<br />
N P<br />
TRAFO<br />
~ ~<br />
MX9<br />
Jumper in right position