University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5497 Olmsted Hall Room <strong>1208</strong> in Riverside, CA<br />

900 University Avenue<br />

1. Doors - At Olmsted Hall Room #<strong>1208</strong> on the First Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Opens a min. of 90 degrees.<br />

1/4” maximum vertical threshold or 1/2” beveled at 1:2.<br />

32” minimum clear width of doorway.<br />

5 lb. maximum pressure to operate exterior doors.<br />

Door hardware is operable with a single effort (lever type, panic bar or push pull type).<br />

Hardware is 30” to 44” above floor.<br />

3 seconds minimum for door closer to close from 70 degree position to within 3” of the latch [ADAAG 404.2.8.1 Door &<br />

gate closers require a 5 second minimum closing time from open position of 90 degree to 12 degree position].<br />

Bottom 10” of door (except automatic or sliding doors) has a smooth uninterrupted surface that allows door to be<br />

opened by a wheelchair footrest without creating a trap or hazardous condition (kick plate).<br />

Areas not meeting new construction standards:<br />

The international symbol of accessibility is posted at all primary entrances.<br />

Recommendation:<br />

Post a sign/decal displaying the ”International Symbol of Accessibility” at the primary entrance.<br />

Provide a compliant ”EXIT” sign.<br />

Photo #UCR P5497 Olmsted Hall Room <strong>1208</strong>-1-1 (originally 1020414)