14.11.2014 Views

ADD OLMSTED Rm 1208

ADD OLMSTED Rm 1208

ADD OLMSTED Rm 1208

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5497 Olmsted Hall Room <strong>1208</strong> in Riverside, CA<br />

900 University Avenue<br />

2. Clear Space at Doors - At Olmsted Hall Room #<strong>1208</strong> on the First<br />

Floor.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 24” width x 60” depth at exterior doors.<br />

Areas not meeting new construction standards:<br />

Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer.<br />

Recommendation:<br />

Requires engineering/architectural evaluation.<br />