REQUEST FOR INFORMATION (<strong>RFI</strong>) : <strong>POLLUTION</strong> <strong>CHECK</strong> <strong>EQPT</strong>-<br />

<strong>DIESEL</strong> <strong>SMOKE</strong> <strong>METER</strong><br />

1. Indian Army is planning to procure Pollution Check Eqpt-Diesel Smoke Meter<br />

(DSM) to implement prevalent pollution emission norms for Defence vehicles. The<br />

equipment should conform to applicable pollution emission norms i.e. BS-III/BS-IV and<br />

must have capability for upgradation to future norms.<br />

2. It is proposed to identify probable ‘Original Equipment Manufacturer’<br />

(OEM)/Vendors who can supply Diesel Smoke Meter to implement applicable pollution<br />

emission norms throughout India for defence vehicles. OEM/Vendors are requested to<br />

forward comprehensive details of theirs Diesel Smoke Meter (DSM) as per<br />

questionnaire attached. The responses are required to be forwarded within 28 days<br />

from the date of publication of this <strong>RFI</strong> at the following address :-<br />

Directorate General of EME (Equipment)<br />

Room No 72B<br />

B Block Hutments<br />

MGO’s Branch<br />

Integrated Head quarters of Ministry of Defence (Army)<br />

DHQ PO, New Delhi-110105<br />

FAX No. 0091-11-23019470


QUESTIONAIRE<br />

Q-1. Has the OEM been accorded approval by any of certifying agencies mentioned<br />

in Rule 126 of Central Motor Vehicle Rules-1981 and any amendments thereto made<br />

by Ministry of Road Transport & Highways for its equipment? If so, please specify<br />

certification agency and attach certificate?<br />

Q-2. Does OEM has obtain conformity to production (COP) from nominated agency?<br />

if so, intimate name of test agency and number of COP obtained till date?<br />

Q-3. What is the principle on which Diesel Smoke Meter functions ?<br />

Q-4. The range, resolution and accuracy (as applicable) of Diesel Smoke Meter<br />

(DSM) for following be mentioned :-<br />

Ser Parameter Range Resolution Accuracy<br />

No<br />

(a) Carbon Monoxide (CO)<br />

measurement<br />

(b) Hydro Carbon (HC)<br />

measurement<br />

(c) HC+NOx measurement<br />

(d) Nitrogen Oxide(NOx)<br />

measurement<br />

(e) PM<br />

(f) Opacity<br />

(g) Absorption<br />

(h) Engine RPM<br />

(j) Oil Temp<br />

(k) HSU<br />

(l) K<br />

(m) Linearity<br />

(n) Time constant<br />

Q-5. Please indicate physical dimensions of the equipment.<br />

(a)<br />

(b)<br />

(c)<br />

(d)<br />

(e)<br />

Length<br />

Breadth<br />

Height<br />

Weight<br />

Length of sample probe.<br />

(f) Length of measuring chamber.<br />

Q-6. Please intimate ‘Warm Up’ time of the equipment.<br />

Q-7. The followings environmental conditions and operating conditions for effective<br />

functioning of DSM be intimated:-<br />

(a)<br />

Operating temperature


(b)<br />

(c)<br />

(d)<br />

Humidity<br />

Power Supply<br />

Any other conditions if applicable.<br />

Q-8. Please intimate method of gas sampling.<br />

Q-9. Does your eqpt has provision of avoiding incorrect measurement?<br />

Q-10. Does your eqpt has built-in functional checks for satisfactory operation of the<br />

eqpt?<br />

Q-11. Please intimate the following information with respect to smoke measurement :-<br />

(a)<br />

(b)<br />

(c)<br />

(d)<br />

(e)<br />

(f)<br />

Range<br />

Resolution<br />

Accuracy<br />

Display<br />

Response time<br />

Smoke chamber temperature<br />

Q-12. Please intimate the following information with respect to Oil temperature<br />

measurement:-<br />

(a)<br />

(b)<br />

(c)<br />

(d)<br />

(e)<br />

(f)<br />

(g)<br />

Range<br />

Resolution<br />

Accuracy<br />

Sensor<br />

Sensor length<br />

Sensor cable length<br />

Display<br />

Q-13. Please intimate the following information with respect to Engine speed<br />

measurement:-<br />

(a)<br />

(b)<br />

(c)<br />

Range<br />

Resolution<br />

Accuracy


(d)<br />

(e)<br />

(f)<br />

(g)<br />

Type<br />

Sensor cable length<br />

Display<br />

Display update time<br />

Q-14. Does the Diesel Smoke Meter manufactured by OEM has following<br />

capabilities/facilities:-<br />

(a) Facilities of measure engine RPM. - Yes/No/NA<br />

(b)<br />

Option to measure NOx and up-gradable to future norms as applicable.<br />

- Yes/No/NA<br />

(c) Does the accuracy of systems conforms to MoRTH/CMVR/TAP 115/116<br />

Chapter-3? - Yes/No/NA<br />

(d) Capability to measure all the parameters as laid out in rule 116(3) of<br />

CMVR for BS IV compliant vehs. - Yes/No/NA<br />

(e) Microprocessor based Auto Calibration - Yes/No/NA<br />

(f) Stand by Mode - Yes/No/NA<br />

(g) Alphanumeric display with backlight - Yes/No/NA<br />

for day/night operation<br />

(h) Interfacing port for computer communication - Yes/No/NA<br />

(j) Operatable on commercial AC supply/ - Yes/No/NA<br />

Rechargeable DC power supply<br />

(k) Self diagnostic/check type - Yes/No/NA<br />

(l) Low voltage warning indication - Yes/No/NA<br />

(m) Leak check facility - Yes/No/NA<br />

(n) Filter blockage warning - Yes/No/NA<br />

(o) Low flow warning - Yes/No/NA<br />

Q-15. Does printout generated by inbuilt printer of DSM will depict the followings :-<br />

(a) Photographed number plate of vehicle under check (if connected to<br />

computer and web camera). - Yes/No/NA<br />

(b) Time and date of test. - Yes/No/NA<br />

(c) Permitted emission limits as per BS III/BS IV norms or as applicable as<br />

per emission limits as per CMVR Rule, 116 (3) 1989. - Yes/No/NA


(d) Measurement result along with Cleared/Not - Yes/No/NA<br />

cleared or Pass/ Fail result.<br />

(e) Name of workshop/unit. - Yes/No/NA<br />

Q-16. Does the equipment of the OEM/Vendors is “Network Enabled”, to facilitate<br />

monitoring of data from centralized location? If yes, provide details of hardware and<br />

software.<br />

Q-17. The OEM/Vendor is requested to intimate minimum Battery Back up being<br />

provided with the eqpt.<br />

Q-18. Enclose the list of tools to be provided with Diesel Smoke Meter? Provide<br />

details in range & depth.<br />

Q-19. Please intimate details of marking on warning plate of Diesel Smoke Meter.<br />

Q-20. What is the warranty period of the Diesel Smoke Meter ?<br />

Q-21. Does OEM/Vendors has capacity & requisite infrastructure for providing training<br />

in first line maintenance and basic trouble shooting of Diesel Smoke Meter ?<br />

Q-22. Will vendors/OEM able to provide following technical literature along with the<br />

Diesel Smoke Meter?<br />

(a)<br />

(b)<br />

Governing drawings and technical specifications.<br />

User hand book including maintenance instruction (bilingual).<br />

(c) Technical Manuals i.e. Illustrated Spares Part List (ISPL) and workshop<br />

repair manual.<br />

(d) Manufacturers Recommended List of Spares (MRLS) along with cost for<br />

maintenance of 24 months.<br />

(e)<br />

List of SMTs/STEs and gauges along with cost.<br />

Q-23. Please intimate details of service network throughout the country.<br />

Q-24. Please intimate list of government department/undertaking/ autonomous<br />

bodies/Corporate sector to whom the OEM has supplied DSM and enclose the proof<br />

of satisfactory performance of the equipment.