Electricity <strong>Meter</strong>s BS<br />
RESIDENTIAL<br />
Landis+Gyr Domestic<br />
ZCE117AC / ZCE127AC<br />
ZCE118AC / ZCE128AC<br />
TECHNICAL DATA<br />
Frequency<br />
Rated frequency fn<br />
selectable: 50 or 60 Hz<br />
Measuring accuracy<br />
to IEC 62053-21 Class 1 and 2<br />
Power consumption<br />
Power consumption in voltage circuit<br />
< 2 W<br />
Power consumption in current circuit<br />
< 0.25 VA<br />
Voltage<br />
ZCE117 / ZCE127 Rated voltage Un 230 V<br />
ZCE118 / ZCE128 Rated voltage Un 120 V<br />
Voltage range<br />
80% - 115 % Un<br />
Operating behaviour<br />
Voltage interruption (Power Down)<br />
Blocking of inputs and outputs immediate<br />
Standby operation<br />
for 0.2 s<br />
Data storage<br />
after 0.2 s<br />
Switch off<br />
after approx. 0.3 s<br />
Restoration of voltage (Power Up)<br />
Function standby<br />
(depending on duration of failure)<br />
Detection of energy direction<br />
and phase voltage<br />
< 5 s<br />
< 5 s<br />
Current<br />
Base current Ib<br />
Starting current<br />
5, 10 or 20 A<br />
0.5 % Ib<br />
Environmental influences<br />
Temperature range<br />
Operation -25 °C − +60 °C<br />
Storage -40 °C − +70 °C<br />
Maximum current Imax<br />
metrological<br />
thermal<br />
short-circuit ≤ 10 ms<br />
100 A<br />
120 A<br />
3000 A<br />
Temperature coefficient<br />
Range<br />
from -20°C − +55°C<br />
Typical mean value<br />
± 0.02 % per K<br />
cosϕ=1 (from 0.1 Ib to Imax) ± 0.05 % per K<br />
cosϕ=0.5 (from 0.2 Ib to Imax) ± 0.075 % per K<br />
Impermeability to IEC 60529 IP 52<br />
H 71 0200 0260 a en - ZCE117AC / ZCE127AC ZCE118AC / ZCE128AC - Technical Data<br />
Landis+Gyr<br />
1 / 4
Electromagnetic Compatibility<br />
Electrostatic discharges to IEC 61000-4-2<br />
Contact discharges<br />
8 kV<br />
Electromagn. high frequency fields to IEC 61000-4-3<br />
80 MHz to 2 GHz at least 10 V/m<br />
Radio interference suppression to IEC/CISPR 22 Cl B<br />
Line transients (burst) to IEC 61000-4 with basic<br />
current I b :<br />
for current and voltage circuits<br />
2 kV<br />
for auxiliary circuits > 40 V<br />
1 kV<br />
with open current circuit<br />
for voltage and current circuits<br />
4 kV<br />
Surge immunity test to IEC 61000-4-5<br />
Impulse voltage<br />
6 kV<br />
Impedance of source<br />
2 Ω<br />
Rise-/ Decay time of impulse voltage 1.2 µs / 50 µs<br />
Rise- / Decay time of current 8 µs / 20 µs<br />
Insulation strength<br />
Insulation strength<br />
4 kV at 50 Hz for 1 min.<br />
Impulse voltage strength to IEC 62053-11<br />
Impulse voltage<br />
8 kV<br />
Impedance of source<br />
500 Ω<br />
Rise- /Decay time of impulse voltage 1.2 µs / 50 µs<br />
Optical Test Output<br />
Type<br />
Infrared LED<br />
physically combined with optical interface<br />
(i.e. infrared-LED is integrated in optical interface)<br />
Pulse length<br />
approx. 2 ms<br />
<strong>Meter</strong> constant R<br />
2000 imp/kWh<br />
Pulse output r53 (optional)<br />
Optional available for the single rate version only<br />
Type<br />
S0 interface<br />
Standard IEC 61393 / DIN 43864<br />
- Values 1000 imp/kWh<br />
Operating conditions<br />
- Supply voltage (nominal value) 24 V DC<br />
- Maximum supply voltage 50 V DC<br />
- Current 10 to 20 mA DC<br />
- Pulse length configurable from 10 … 120 ms<br />
in 10 ms steps<br />
- Default value 80 ms<br />
Communication Interface<br />
Optical interface<br />
Type<br />
serial, bi-directional interface<br />
Standard IEC 62056-21<br />
Application<br />
Data readout according to IEC 62056-21 (all data)<br />
Factory parameterisation<br />
Test output (physically combined with test diode)<br />
Protection class to IEC 60050-131 2<br />
Display<br />
Characteristics<br />
Type<br />
LCD liquid crystal display<br />
Digit size<br />
8.4 mm<br />
Number of digits 6<br />
Inputs and Outputs<br />
Control Inputs optional<br />
Control voltage Ut<br />
230 V<br />
Permissible range<br />
0.8 up to 1.15 x Ut<br />
Current input<br />
< 2 mA ohmic at 230 V<br />
(two rate version cannot include r53 option)<br />
Landis+Gyr<br />
2 / 4<br />
H 71 0200 0260 a en - ZCE117AC / ZCE127AC ZCE118AC / ZCE128AC - Technical Data
Weight and Dimensions<br />
Weight<br />
External dimensions<br />
Width<br />
Height (with short terminal cover)<br />
Height (with long terminal cover)<br />
Depth (without terminal cover)<br />
Depth (with terminal cover)<br />
Suspension<br />
Horizontal two screw suspension only<br />
Width<br />
Terminal cover<br />
Short<br />
Long<br />
approx. 300 g<br />
comply with BS<br />
125 mm<br />
80 mm<br />
125 mm<br />
32 mm<br />
42 mm<br />
105 mm<br />
no free space<br />
45 mm free space<br />
Connections<br />
Mains<br />
Type<br />
screw type terminals<br />
Diameter<br />
9.5 mm<br />
Minimum conductor cross-section 4 mm 2<br />
max. cross-section cable 35 mm 2<br />
max. cross-section strand 25 mm 2<br />
Screw dimensions M6 x 14<br />
head diameter<br />
max. 6.6 mm<br />
slot<br />
0.8 +0.2/+0.06 mm<br />
Tightening torque<br />
max. 3 Nm<br />
Other connections<br />
Type<br />
screw type terminal<br />
Max. cross-section cable / strand 2.5 mm 2<br />
Tightening torque<br />
max. 0.6 Nm<br />
Terminal layout and dimensions<br />
Dimensions (with short terminal cover)<br />
125 30 2<br />
ZCE127<br />
25 20 25<br />
70<br />
18<br />
78<br />
80<br />
42<br />
Dimensions (with long terminal cover)<br />
125 30<br />
2<br />
ZCE127<br />
125<br />
78<br />
42<br />
H 71 0200 0260 a en - ZCE117AC / ZCE127AC ZCE118AC / ZCE128AC - Technical Data<br />
Landis+Gyr<br />
3 / 4
Type designation<br />
ZCE 127 AC d r53<br />
Network type<br />
ZCD Single-phase two-wire network<br />
Connection type<br />
117 Direct connection 230 V, IEC class 1, BS<br />
127 Direct connection 230 V, IEC class 2, BS<br />
118 Direct connection 120 V, IEC class 1, BS<br />
128 Direct connection 120 V, IEC class 2, BS<br />
Measurement variants<br />
AC Simple active energy meter<br />
Tariff functions<br />
e<br />
d<br />
with single-rate tariff<br />
with double-rate tariff<br />
Pulse retransmission<br />
r53 Transistor output, S0 according IEC 61393/DIN 43 864,<br />
pulse length ti variable<br />
Landis+Gyr Ltd.<br />
Feldstrasse 1<br />
CH – 6301 Zug<br />
Switzerland<br />
Phone: +41 41 724 41 41<br />
www.landisgyr.com<br />
Landis+Gyr<br />
4 / 4<br />
H 71 0200 0260 a en - ZCE117AC / ZCE127AC ZCE118AC / ZCE128AC - Technical Data