<strong>Grant</strong> Aerona Air Source<br />

Heat Pump range<br />

Air to water heat pumps with outputs from 6.5kW to 21.5kW<br />

Two ranges available • High COP’s • MCS approved models • Built-in 3kW electric immersion • High quality powder coated paint finish<br />

Simple plumbing and electrical connections • Compact design with common footprint for all units • All models are single phase<br />

Factory fitted weather compensator with dual temperature control


<strong>Grant</strong> profile<br />

At <strong>Grant</strong> we have been designing and<br />

manufacturing reliable and easy to install heating<br />

products for over 35 years. From award winning<br />

oil-fired condensing boilers to the latest renewable<br />

technologies, our heating systems have a reputation<br />

for quality that is second to none.<br />

We combine precision engineering, innovation,<br />

performance and value for money to produce<br />

sustainable heating solutions that are trusted<br />

by both installers and householders.<br />

Quality design<br />

There is never a compromise on<br />

quality. We design all of our products<br />

so that you can be sure that the durability<br />

and efficiency are sector leading. We<br />

continually develop new technologies<br />

and use only the best materials to ensure<br />

our products meet all performance and<br />

environmental standards.<br />

Our belief in simple solutions<br />

ensures that, while our technology is<br />

sophisticated, our products are low<br />

maintenance and easy to install. For<br />

a high quality, reliable and sustainable<br />

heating system, trust in <strong>Grant</strong>.<br />

Heating responsibly<br />

<strong>Grant</strong> manufacture heating products that<br />

respond to the challenges of rising fuel<br />

costs whilst protecting our environment.<br />

Environmental responsibility is central<br />

to all we do and we continue to develop<br />

and innovate to produce even more<br />

efficient products that make best use of<br />

our natural resources.<br />

We are passionate about developing<br />

sustainable, high-performance and<br />

affordable alternatives for heating<br />

homes into the future.<br />

Our guarantee<br />

The <strong>Grant</strong> label is a guarantee of<br />

reliability, quality and value. We put our<br />

customers first and our independence<br />

ensures that we can monitor our<br />

standards and processes to deliver<br />

the very best quality and service.<br />

That’s why, when you order your system<br />

from a <strong>Grant</strong> stockist, you can be sure<br />

of a tailored service and excellent<br />

aftersales support.<br />

02


Heat pump technology<br />

Air source heat pumps<br />

Air source heat pumps use basic thermodynamic<br />

principles to convert latent heat contained within<br />

the air we breathe into heat energy that can be<br />

used to provide heating and hot water.<br />

This ‘ambient heat’ is replenished by the sun making our heat<br />

pumps both effective and environmentally friendly.<br />

Fit for the future<br />

With the recent fluctuations in price and supply of fossil fuels,<br />

air source heat pumps offer both an environmentally and<br />

economically sustainable alternative.<br />

Home heating in the <strong>UK</strong> accounts for approximately 30% of CO2<br />

emissions. The heat source used by <strong>Grant</strong> Aerona heat pumps<br />

is entirely renewable which helps reduce the amount of harmful<br />

greenhouse gases being released into the atmosphere and, in<br />

so doing, lowers the carbon footprint of the household.<br />

How it works<br />

There are two basic types of air source heat pump - ‘air to air’<br />

and ‘air to water’. <strong>Grant</strong> Aerona heat pumps use an air to water<br />

system which utilises heat energy captured from the air in 'wet'<br />

heating system radiators or underfloor heating.<br />

The process uses the same vapour/compression cycle that<br />

extracts heat in a domestic fridge. A refrigerant with a low<br />

boiling point is exposed to external air temperatures in an<br />

evaporator. The liquid boils off to a gas and absorbs the latent<br />

heat energy of the air. This gas is then compressed increasing<br />

the heat content in the refrigerant, before passing through a<br />

heat exchanger where it condenses back to a liquid state while<br />

transferring the heat to the water of the heating system. The<br />

liquid refrigerant is then re-circulated through the evaporator and<br />

the cycle is repeated.<br />

01380 736920 | www.grantuk.com<br />

03


Heat pump installation<br />

Typical system layout<br />

The house below shows a <strong>Grant</strong> Aerona<br />

incorporated into a standard heating system,<br />

comprising heat pump, cylinder, underfloor<br />

heating and radiator circuit.<br />

<strong>Grant</strong> Solar Thermal is also a good match for air source heat<br />

pumps and when combined using one of <strong>Grant</strong>’s high efficiency<br />

heat pump cylinders and solar thermal system, can reduce<br />

home heating bills even further.<br />

<strong>Grant</strong> Solar Thermal<br />

Collectors (optional)<br />

<strong>Grant</strong> Aerona air to<br />

water heat pump<br />

<strong>Grant</strong> DuoWave Twin-coil<br />

Heat Pump cylinder<br />

04


Green savings<br />

Lower heating costs<br />

Compared with other domestic heating methods, a<br />

<strong>Grant</strong> Aerona heat pump can benefit homeowners<br />

by creating annual savings on fuel bills.<br />

The units can deliver around four times the amount of energy for<br />

every 1kW of electricity used (depending on the model, at 7°C<br />

air temperature/35°C water temperature).<br />

Homes utilising this type of heat generator will obviously have a<br />

lower dependency on fossil fuels, making them less susceptible<br />

to rising fuel costs.<br />

About ‘Coefficient of Performance’ (COP)<br />

The COP is the ratio of electrical power required to run the heat<br />

pump, compared with the output being produced to heat the<br />

water of the heating system.<br />

Testing is carried out to European and British Standard BSEN14511<br />

and establishes the output and COP at a specific ambient air and<br />

circuit water temperature. This is 7°C for ambient air and 35°C for<br />

water flow temperature. For example, the <strong>Grant</strong> Aerona ASHE65<br />

model produces 6.5kW at a COP of 4.1, when tested to this level.<br />

This means for every kilowatt (kW) of energy used to run the Aerona,<br />

4.1kW of energy is being given to the heating system in return.<br />

It is important to note that as the outside air gets colder, the output<br />

and COP of an air source heat pump falls, due to the reduced<br />

amount of heat energy available from the air. Conversely, when<br />

outside air temperature rises above 7°C the output and COP will<br />

increase (see performance graphs on pages 7 and 9).<br />

Comparison of CO2 emissions for domestic home heating<br />

0.4kg<br />

Estimated CO2 released per kWh<br />

0.3kg<br />

0.2kg<br />

0.1kg<br />

Electricity LPG Oil<br />

(Condensing)<br />

Gas<br />

(Condensing)<br />

<strong>ASHP</strong> (COP 3.0)<br />

Renewable<br />

technology<br />

<strong>ASHP</strong> (COP 3.5)<br />

Renewable<br />

technology<br />

<strong>ASHP</strong> (COP 4.0)<br />

Renewable<br />

technology<br />

Comparison of kWh costs for domestic home heating<br />

£0.14<br />

Estimated cost per kWh used<br />

£0.12<br />

£0.10<br />

£0.08<br />

£0.06<br />

£0.04<br />

£0.02<br />

Electricity LPG Oil<br />

(Condensing)<br />

Gas<br />

(Condensing)<br />

<strong>ASHP</strong> (COP 3.0)<br />

Renewable<br />

technology<br />

<strong>ASHP</strong> (COP 3.5)<br />

Renewable<br />

technology<br />

<strong>ASHP</strong> (COP 4.0)<br />

Renewable<br />

technology<br />

01380 736920 | www.grantuk.com<br />

05


<strong>Grant</strong> Aerona range<br />

The Aerona<br />

Our original range of single phase air to water<br />

heat pumps, feature weather compensation, dual<br />

temperature controls and a 3kW immersion backup.<br />

The integration of weather compensation with these controls<br />

allows the unit to perform very efficiently, giving a reliable heat<br />

output and using less power, resulting in lower running costs.<br />

The design also makes installation straightforward into either<br />

a new or existing S-plan type system configuration.<br />

The Aerona is available in outputs of 6.5kW, 8.5kW, 11kW and<br />

13kW (Note: this output does not include the immersion back up).<br />

Design<br />

<strong>Grant</strong> has combined tried and tested technology with<br />

sophisticated control equipment to give customers the benefit<br />

of efficient and reliable renewable heating with every Aerona air<br />

source heat pump.<br />

The performance of a heat pump is affected by outside air<br />

temperature. <strong>Grant</strong>’s factory fitted weather compensating device<br />

enables Aerona heat pumps to accurately monitor outside<br />

temperature conditions and precisely control its operation,<br />

maximising efficiency.<br />

The units are pre-plumbed and pre-wired with an independent<br />

heating element that automatically provides a boost on the<br />

rare occasion when the air temperature falls to very low levels.<br />

It is also possible to incorporate and control a secondary heat<br />

source with this arrangement e.g. gas, oil-fired, biomass boiler<br />

(Bivalent system).<br />

The <strong>Grant</strong> Aerona is very compact, requires no additional<br />

storage space for fuel and being sited externally, leaves more<br />

valuable space inside the home. The units come complete<br />

with a galvanised steel casing, featuring a proven high quality<br />

external powder coated paint finish, which protects the internal<br />

components and case from weathering.<br />

Technical specifications<br />

Model HPAW65 HPAW85 HPAW110 HPAW130<br />

Height (mm) 820 1065 1165 1165<br />

Width (mm) 1120 1120 1120 1120<br />

Depth (mm) 430 430 430 430<br />

Weight (kg)<br />

Empty<br />

Full<br />

100<br />

111<br />

119<br />

134<br />

139<br />

156<br />

144<br />

170<br />

Water proof level IPX4 IPX4 IPX4 IPX4<br />

Refrigerant R407C R407C R407C R407C<br />

Operating voltage (v) 230 (1 phase) 230 (1 phase) 230 (1 phase) 230 (1 phase)<br />

Flow/return tappings (BSPF) 3/4" 3/4" 1" 1"<br />

Integrated heating element (kW) 3 3 3 3<br />

Min/max operating temperatures - Air (°C) -15 to +25 -15 to +25 -15 to +25 -15 to +25<br />

Max flow temperatures - Water (°C) 55 55 55 55<br />

Compressor Rotary Rotary Scroll Scroll<br />

Base tray trace element Yes Yes Yes Yes<br />

Sound power level at 1 metre (dB(A)) * 64 65 71.5 73.3<br />

Sound pressure level at 1 metre (dB(A)) * 49.2 50 57 58.5<br />

Starting current (A) rms 25 24 28 36<br />

Nominal running current (A) 9.1 10.7 14 16.1<br />

* In accordance with BSENISO3744:1995<br />

06


Performance data<br />

Features<br />

• High COP’s<br />

• MCS approved<br />

• R407C refrigerant<br />

• All models are single phase<br />

• Outputs from 6.5kW-13kW<br />

• Built-in 3kW immersion backup<br />

• Simple plumbing and electrical connections<br />

• Compact design with common footprint for all models<br />

• Weather compensating control<br />

• Base tray heating element<br />

• Extendable condensate deflector<br />

• 2 year product guarantee (extendable to 5 years)<br />

Model<br />

Air temp.<br />

Water temp.<br />

7°C 0°C -3°C Performance curve<br />

35°C * 35°C * 35°C *<br />

Output<br />

kW<br />

7.0 4.3 4.1<br />

COP 3.8 2.4 2.3<br />

Output kW<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

COP<br />

HPAW65<br />

HPAW65<br />

0<br />

-15<br />

-12<br />

-7<br />

-3<br />

2<br />

Outside temp °C<br />

7<br />

12<br />

15<br />

0<br />

HPAW65<br />

Output<br />

kW<br />

8.4 5.2 5.0<br />

COP 3.8 2.5 2.4<br />

Output kW<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

COP<br />

2<br />

1<br />

0<br />

-15<br />

-12<br />

-7<br />

-3<br />

2<br />

7<br />

12<br />

15<br />

0<br />

HPAW85<br />

HPAW85<br />

Outside temp °C<br />

HPAW110<br />

HPAW110<br />

Output<br />

kW<br />

10.9 6.8 6.4<br />

COP 3.9 2.5 2.4<br />

Output kW<br />

20<br />

18<br />

16<br />

14<br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

-15<br />

HPAW110<br />

-12<br />

-7<br />

-3<br />

2<br />

Outside temp °C<br />

7<br />

12<br />

15<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

COP<br />

Output<br />

kW<br />

12.3 7.5 7.3<br />

COP 3.9 2.4 2.3<br />

Output kW<br />

25<br />

20<br />

15<br />

10<br />

5<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

COP<br />

HPAW130<br />

HPAW130<br />

0<br />

-15<br />

HPAW130<br />

-12<br />

-7<br />

-3<br />

2<br />

Outside temp °C<br />

7<br />

12<br />

15<br />

0<br />

* Tested to BSEN14511<br />

Note: When selecting an Air Source heat pump, ensure output is matched with the correct system design temperature (varies by location)<br />

01380 736920 | www.grantuk.com<br />

07


<strong>Grant</strong> Aerona HE range<br />

The Aerona HE<br />

Following the success of the original Aerona air<br />

to water heat pump models, and in response to<br />

comments and ideas from our customers, <strong>Grant</strong><br />

<strong>UK</strong> has developed the Aerona HE range.<br />

The brief for this was straightforward - bigger single phase models,<br />

higher outputs and COPs at lower air temperatures with quieter<br />

noise levels, whilst maintaining the tried and tested features of<br />

the existing Aerona range. The new Aerona HE is available in<br />

6.5kW, 8.5kW, 12.5kW, 17.5kW and 21.5kW outputs (Note: this<br />

does not include the immersion back up).<br />

Design<br />

To achieve better COP’s, and further reduce running costs, the<br />

Aerona HE range was designed with larger evaporator surface<br />

areas, increasing the amount of air flow through the unit. The<br />

fans run at lower speeds and this coupled with the improved<br />

internal insulation has successfully decreased noise levels. The<br />

HE models also use R410a refrigerant, which allows the unit to<br />

operate at lower ambient temperatures.<br />

As with all products in the Aerona range, the models are designed<br />

to be installer friendly and come complete with factory fitted<br />

weather compensation controls, 3kW electrical backup* and<br />

flexible flow and return connections, so there are no hidden extras.<br />

*Note: to fully comply with MIS3005, the backup heater should not be energised until the<br />

minimum design temperature has been reached (e.g. -3°C).<br />

Features<br />

• High COP’s sustainable at lower temperatures<br />

• R410a refrigerant<br />

• Outputs from 6.5kW-21.5kW<br />

• Built-in 3kW electrical backup<br />

• Improved sound insulation<br />

• Adjustable legs<br />

• All models are single phase<br />

• Weather compensating control<br />

• Base tray heating element<br />

• 2 independently operating compressors<br />

(17.5kW and 21.5kW models only)<br />

• Extendable condensate deflector (all models except 21.5kW)<br />

• Simple plumbing and electrical connections<br />

• 2 year product guarantee (extendable to 5 years)<br />

Technical specifications<br />

Model ASHE65 ASHE85 ASHE125 ASHE175 ASHE215<br />

Height (mm) 1077 1378 1378 1528 1452<br />

Width (mm) 1117 1117 1117 1117 1537<br />

Depth (mm) 427 427 427 679 679<br />

Weight (kg)<br />

Empty<br />

Full<br />

116<br />

121<br />

145<br />

151<br />

173<br />

181<br />

233<br />

245<br />

334<br />

346<br />

Water proof level IPX4 IPX4 IPX4 IPX4 IPX4<br />

Refrigerant R410a R410a R410a R410a R410a<br />

Operating voltage (v) 230 (1 phase) 230 (1 phase) 230 (1 phase) 230 (1 phase) 230 (1 phase)<br />

Flow/return tappings (BSPF) 3/4" 3/4" 1" 1" 1"<br />

Integrated heating element (kW) 3 3 3 3 3<br />

Min/max operating temperatures - Air (°C) -20 to +30 -20 to +30 -20 to +30 -20 to +30 -20 to +30<br />

Max flow temperatures - Water (°C) 60 60 60 60 60<br />

Compressor Rotary Rotary Scroll 2 x Rotary 2 x Scroll<br />

Base tray trace element Yes Yes Yes Yes Yes<br />

Sound power level at 1 metre (dB(A)) * 62.5 63 64 68.5 63<br />

Sound pressure level at 1 metre (dB(A)) * 48 48 49 53 48.5<br />

Starting current (A) (rms) 26 26 45 28/37 50/60<br />

Nominal running current (A) 7.2 9.2 13.3 10.3/20.5 12.3/24.4<br />

* In accordance with BSENISO3744:1995<br />

08


Performance data<br />

Model<br />

Air temp.<br />

Water temp.<br />

7°C 0°C -3°C<br />

35°C * 35°C * 35°C *<br />

Performance curve<br />

14.0<br />

9.0<br />

Output<br />

kW<br />

6.7 4.4 4.3<br />

COP 4.1 2.9 2.7<br />

Output kW<br />

12.0<br />

10.0<br />

8.0<br />

6.0<br />

4.0<br />

2.0<br />

8.0<br />

7.0<br />

6.0<br />

5.0<br />

4.0<br />

3.0<br />

2.0<br />

1.0<br />

COP<br />

ASHE65<br />

ASHE65<br />

0.0<br />

-20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 0.0<br />

Outside temp °C<br />

Output<br />

kW<br />

8.8 6.7 6.0<br />

COP 4.3 3.1 2.8<br />

Output kW<br />

16.0<br />

14.0<br />

12.0<br />

10.0<br />

8.0<br />

6.0<br />

4.0<br />

9.0<br />

6.0<br />

5.0<br />

4.0<br />

3.0<br />

2.0<br />

COP<br />

2.0<br />

1.0<br />

ASHE85<br />

ASHE85<br />

0.0<br />

-20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 0.0<br />

Outside temp °C<br />

Output<br />

kW<br />

12.3 8.5 8.0<br />

COP 4.0 2.9 2.6<br />

Output kW<br />

25.0<br />

20.0<br />

15.0<br />

10.0<br />

8.0<br />

7.0<br />

6.0<br />

5.0<br />

4.0<br />

3.0<br />

COP<br />

5.0<br />

2.0<br />

1.0<br />

ASHE125<br />

ASHE125<br />

0.0<br />

-20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 0.0<br />

Outside temp °C<br />

25.0<br />

9.0<br />

Output<br />

kW<br />

17.8 12.0 11.7<br />

COP 4.0 2.8 2.6<br />

Output kW<br />

20.0<br />

15.0<br />

10.0<br />

Compressor (1+2)<br />

Compressor (1)<br />

8.0<br />

7.0<br />

6.0<br />

5.0<br />

4.0<br />

3.0<br />

COP<br />

5.0<br />

2.0<br />

ASHE175<br />

ASHE175<br />

1.0<br />

0.0<br />

-20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 0.0<br />

Outside temp °C<br />

30.0<br />

7.0<br />

Output<br />

kW<br />

21.2 15.5 15<br />

25.0<br />

20.0<br />

Compressor (1+2)<br />

6.0<br />

5.0<br />

COP 3.9 2.9 2.7<br />

Output kW<br />

15.0<br />

10.0<br />

Compressor (1)<br />

4.0<br />

3.0<br />

2.0<br />

COP<br />

5.0<br />

1.0<br />

ASHE215<br />

ASHE215<br />

0.0<br />

-20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 0.0<br />

Outside temp °C<br />

* Tested to BSEN14511<br />

Note: When selecting an Air Source heat pump, ensure output is matched with the correct system design temperature (varies by location)<br />

01380 736920 | www.grantuk.com<br />

09


General information<br />

Installation and maintenance<br />

The installation of a <strong>Grant</strong> Aerona heat pump should be<br />

carried out by a <strong>Grant</strong> G-One accredited heat pump installer.<br />

More information on this scheme is available from the <strong>Grant</strong><br />

<strong>UK</strong> website.<br />

Servicing should be carried out annually by a qualified heating<br />

engineer. During servicing it is important for the engineer to<br />

ensure that the evaporator matrix is clear of debris as any build<br />

up could significantly affect the performance of the heat pump.<br />

Guarantees<br />

<strong>Grant</strong> Aerona heat pumps are guaranteed for 2 years from the<br />

date of purchase (excluding consumable items), subject to<br />

being serviced annually and installed in accordance with the<br />

manufacturer’s instructions. This warranty can also be extended<br />

to 5 years for an additional fee. See the Aerona installation<br />

manual for further details.<br />

On completion of the installation all <strong>Grant</strong> Aerona heat pumps<br />

must be commissioned and registered online at:<br />

www.grantuk.com<br />

Renewable Heat Incentive<br />

Currently in the <strong>UK</strong>, just under half of our carbon emissions<br />

are created by heating buildings and water. Over 99% of this<br />

is predominantly supplied by fossil fuels and less than 1% by<br />

renewable energy. The proposed Renewable Heat Incentive<br />

(RHI) has been designed by the Department of Energy & Climate<br />

Change (DECC) to alter this way of living, so that by 2020, 12%<br />

of heat is generated by renewable technology, thereby cutting<br />

carbon emissions and allowing the <strong>UK</strong> to hit its binding EU targets.<br />

From October 2012, the RHI guarantees long-term payments<br />

for the end user on specified renewable installations. It includes<br />

all types of heating, from households to factories and public<br />

sector buildings. The tariffs, which will be annually adjusted<br />

with inflation, will be paid for a number of years to eligible<br />

technologies installed since 15th July 2009 with payments being<br />

made for each kWh of renewable heat produced.<br />

It is important to remember that the end user can only claim<br />

cash-back through the RHI if the product and installer are<br />

both MCS approved. MCS is an independent scheme for the<br />

certification of microgeneration products and installers. It is<br />

designed to assess these products and installers against robust<br />

criteria, which provides greater protection for consumers when<br />

fitting renewable technologies to their property.<br />

Approvals<br />

<strong>Grant</strong> Aerona heat pumps are manufactured using CE approved<br />

components and include a BEAB certified 3kW immersion<br />

element. To ensure performance standards, the units have been<br />

tested and approved in a <strong>UK</strong> test house to BSEN14511.<br />

All heat pump cylinders are manufactured in accordance with<br />

BS EN12897 the specification for unvented hot water storage<br />

vessels. They all comply with Building Regulations G3 and<br />

Water Regulations. Cylinder performance complies with the<br />

requirements BSEN806, BS1566 and BS7206 and meets the<br />

NHBC criteria.<br />

Aftersales service<br />

For peace of mind, all <strong>Grant</strong> Aerona heat pumps are backed<br />

by <strong>Grant</strong>’s comprehensive service operation and in the unlikely<br />

event of a problem occurring, your installer should telephone<br />

our Customer Service Department on: 01380 736920<br />

10


<strong>Grant</strong> Heat Pump cylinders<br />

Duplex stainless steel unvented indirect mains<br />

pressure cylinders for either the <strong>Grant</strong> Aerona or<br />

combining heat pumps with solar thermal systems.<br />

Heat pump cylinders<br />

<strong>Grant</strong> has introduced a range of<br />

stainless steel cylinders specifically<br />

matched to the Aerona, which<br />

incorporate a larger primary coil for<br />

quicker heat transference.<br />

The new cylinders are available in<br />

seven indirect single coil versions,<br />

ranging from 125-400 litres and five<br />

indirect twin coil versions ranging<br />

from 170-400 litres.<br />

<strong>Grant</strong> heat pump cylinders feature<br />

compression fittings which are<br />

conveniently located to make<br />

installation quicker and easier.<br />

For more information and sizes, visit our website: www.grantuk.com<br />

Domestic Hot Water<br />

(DHW) Boost kit<br />

Whilst it is possible to raise the DHW to 60°C with<br />

an Aerona heat pump, it can be more efficient to<br />

set the hot water temperature between 45°C and<br />

50°C and utilise <strong>Grant</strong>’s Domestic Hot Water Boost<br />

kit to take the cylinder up to the desired higher<br />

temperature. This unit comprises an enclosure<br />

with 20A rated contactor, an override switch and relay, which<br />

works with the immersion element fitted in all <strong>Grant</strong> cylinders.<br />

Sealed system kits<br />

Sealed system kits are available to<br />

suit all heat pump models. The kits<br />

come in either a 12ltr or 18ltr size<br />

for standard systems and a 50ltr<br />

size for use with the ThermaWave<br />

thermal store.<br />

For further information, see the<br />

<strong>Grant</strong> product price list.<br />

<strong>Grant</strong> MonoWave Heat Pump cylinders unvented indirect single coil duplex stainless steel<br />

Model<br />

Capacity<br />

(ltrs)<br />

Pressure<br />

regulator<br />

(bar)<br />

Immersion<br />

fitted<br />

(kW)<br />

Expansion<br />

vessel<br />

(ltrs)<br />

Coil rating<br />

primary<br />

(kW)<br />

Standing<br />

heat loss<br />

(kW/24hrs)<br />

Dimensions<br />

height<br />

(mm)<br />

Dimensions<br />

diameter<br />

(mm)<br />

HPMONO/IND125 125 3 3 12 24.0 1.70 800 580 30 155<br />

HPMONO/IND150 150 3 3 12 27.8 1.92 890 580 32 182<br />

HPMONO/IND170 170 3 3 19 27.8 2.04 1075 580 45 215<br />

HPMONO/IND200 200 3 3 19 47.0 2.45 1230 580 49 249<br />

HPMONO/IND250 250 3 3 24 47.0 2.69 1480 580 59 309<br />

HPMONO/IND300 300 3 3 24 56.6 2.71 1745 580 68 368<br />

HPMONO/IND400 400 3 3 35 56.6 2.94 2110 580 76 476<br />

Weight<br />

empty<br />

(kg)<br />

Weight<br />

full<br />

(kg)<br />

<strong>Grant</strong> MonoWave Heat Pump cylinders unvented indirect solar twin coil duplex stainless steel<br />

Model<br />

Capacity<br />

(ltrs)<br />

Solar<br />

(kW)<br />

Pressure<br />

regulator<br />

(bar)<br />

Immersion<br />

fitted<br />

(kW)<br />

Expansion<br />

vessel<br />

(ltrs)<br />

Note: <strong>Grant</strong> MonoWave and DuoWave Heat Pump cylinders include a factory-fitted temperature<br />

and pressure relief valve, set to operate at 7 bar and 90°C.<br />

Coil rating<br />

primary<br />

(kW)<br />

Standing<br />

heat loss<br />

(kW/24hrs)<br />

Dimensions<br />

height<br />

(mm)<br />

Dimensions<br />

diameter<br />

(mm)<br />

HPDUO/IND170 170 3 3 19 32 8.5 2.04 1075 580 57 227<br />

HPDUO/IND200 200 3 3 19 47 10 2.45 1230 580 61 261<br />

HPDUO/IND250 250 3 3 24 47 16 2.69 1480 580 71 321<br />

HPDUO/IND300 300 3 3 24 55.6 16 2.71 1745 580 80 380<br />

HPDUO/IND400 400 3 3 35 55.6 23 2.94 2110 580 100 500<br />

Weight<br />

empty<br />

(kg)<br />

Weight<br />

full<br />

(kg)<br />

01380 736920 | www.grantuk.com<br />

11


This leaflet is accurate at the time of printing but as <strong>Grant</strong> <strong>UK</strong> has a policy of continual<br />

improvement it may be superseded. We reserve the right to amend specifications<br />

without prior notice. The statutory rights of the consumer are not affected.<br />

All products manufactured under I.S. EN ISO 9001 and ISO 14001.<br />

THE GRANT ‘EZ-FIT FLUE’ SYSTEM is a trade mark of <strong>Grant</strong> Engineering Limited.<br />

®<strong>Grant</strong> Aerona, <strong>Grant</strong> Spira, <strong>Grant</strong> Vecta, <strong>Grant</strong> Vortex, <strong>Grant</strong> Solar, <strong>Grant</strong> Aurora,<br />

<strong>Grant</strong> Sahara, <strong>Grant</strong> CombiSOL, <strong>Grant</strong> WinterSOL, <strong>Grant</strong> MonoWave, <strong>Grant</strong><br />

DuoWave, <strong>Grant</strong> ThermaWave, Euroflame and Multi Pass are registered trade<br />

marks of <strong>Grant</strong> Engineering Limited. The contents of this leaflet are fully protected<br />

by copyright and nothing may be reproduced without permission from <strong>Grant</strong> <strong>UK</strong>.<br />

<strong>Grant</strong> Engineering (<strong>UK</strong>) Ltd<br />

Hopton House, Hopton Industrial Estate,<br />

Devizes, Wiltshire, SN10 2EU<br />

T: 01380 736920 F: 01380 736991<br />

E: sales@grantuk.com w: www.grantuk.com<br />

GHPB 02/13 <strong>UK</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!