CH (NOTE #9)<br />

RED or BLK<br />

RED or BLK<br />

COMP BLU<br />

CONT<br />

L1<br />

BLK C S H<br />

208/23010<br />

L2 11 21<br />

POWER<br />

R C<br />

SUPPLY<br />

13 23 YEL<br />

YEL F<br />

EQUIP<br />

GND<br />

OFM BRN<br />

BLK<br />

BLU<br />

(SEE NOTE #14)<br />

BLU<br />

BLU<br />

Y<br />

G<br />

CONNECTION DIAGRAM<br />

LLS<br />

R<br />

BLK<br />

VIO<br />

HPS DTS LPS<br />

BLU BLU BLK BLK YEL YEL<br />

BLK<br />

BLK<br />

YEL<br />

IFR<br />

CAP<br />

BRN<br />

YEL<br />

BLK<br />

BLU<br />

BLU<br />

YEL<br />

BRN<br />

SC<br />

(NOTE #8)<br />

BRN<br />

T2<br />

LOGIC<br />

T1 T3<br />

CTD<br />

C<br />

R<br />

ST<br />

1 2<br />

5<br />

SR<br />

EXTERNAL<br />

POWER<br />

SUPPLY<br />

24 V<br />

(NOTES #3 & #6)<br />

CONT<br />

CAP<br />

CH<br />

COMP<br />

CTD<br />

DTS<br />

HPS<br />

IFR<br />

LLS<br />

LPS<br />

OFM<br />

SC<br />

SR<br />

ST<br />

- LEGEND -<br />

FACTORY POWER WIRING<br />

FACTORY CONTROL WIRING<br />

FIELD CONTROL WIRING<br />

FIELD POWER WIRING<br />

COMPONENT CONNECTION<br />

FIELD SPLICE<br />

JUNCTION<br />

CONTACTOR<br />

CAPACITOR (DUAL RUN)<br />

CRANKCASE HEATER<br />

COMPRESSOR<br />

COMPRESSOR TIME DELAY<br />

DISCHARGE TEMP. SWITCH<br />

HIGH PRESSURE SWITCH<br />

INDOOR FAN RELAY<br />

LIQ. LINE SOLENOID VALVE<br />

LOW PRESSURE SWITCH<br />

OUTDOOR FAN MOTOR<br />

START CAPACITOR<br />

START RELAY<br />

START THERMISTOR<br />

INDOOR<br />

THERMOSTAT<br />

(NOTE #5)<br />

INDOOR<br />

BLOWER<br />

MOTOR<br />

MAY BE FACTORY OR FIELD<br />

INSTALLED<br />

EQUIP<br />

GND<br />

Y<br />

G<br />

R<br />

L1<br />

INDOOR<br />

THERMOSTAT<br />

CH<br />

CONT<br />

11 21<br />

5 2<br />

1<br />

SR<br />

(SEE NOTE #14)<br />

SCHEMATIC DIAGRAM<br />

(LADDER FORM)<br />

SC<br />

HPS DTS LPS<br />

IFR<br />

R C<br />

OFM<br />

LLS<br />

EXTERNAL<br />

POWER<br />

SUPPLY 24 V<br />

R<br />

C<br />

S<br />

H<br />

C<br />

F<br />

COMP<br />

CAP<br />

CTD<br />

ST<br />

T2<br />

LOGIC<br />

T1 T3<br />

L2<br />

CONT<br />

23 13<br />

CONT<br />

NOTES:<br />

1. SYMBOLS ARE ELECTRICAL <br />

REPRESENTATION ONLY.<br />

2. COMPRESSOR AND FAN MOTOR FURNISHED<br />

WITH INHERENT THERMAL PROTECTION.<br />

3. TO BE WIRED IN ACCORDANCE WITH<br />

NATIONAL ELECTRIC N.E.C. AND LOCAL<br />

CODES.<br />

4. N.E.C. CLASS 2, 24 V CIRCUIT, MIN 40 VA <br />

REQUIRED, 60 VA ON UNITS INSTALLED<br />

WITH LLS.<br />

5. USE COPPER CONDUCTORS ONLY.<br />

6. CONNECTION FOR TYPICAL COOLING ONLY <br />

THERMOSTAT. FOR OTHER<br />

ARRANGEMENTS SEE INSTALLATION<br />

INSTRUCTIONS.<br />

7. IF INDOOR SECTION HAS A TRANSFORMER<br />

WITH A GROUNDED SECONDARY, CONNECT<br />

THE GROUNDED SIDE TO THE BRN LEAD.<br />

8. WHEN START RELAY AND START <br />

CAPACITOR ARE INSTALLED, START<br />

THERMISTOR IS NOT USED.<br />

9. CH NOT USED ON ALL UNITS.<br />

10.IF ANY OF THE ORIGINAL WIRE, AS<br />

SUPPLIED, MUST BE REPLACED, USE THE<br />

SAME OR EQUIVALENT WIRE.<br />

11.CHECK ALL ELECTRICAL CONNECTIONS<br />

INSIDE CONTROL BOX FOR TIGHTNESS.<br />

12.DO NOT ATTEMPT TO OPERATE UNIT UNTIL<br />

SERVICE VALVES HAVE BEEN OPENED.<br />

13.DO NOT RAPID CYCLE COMPRESSOR.<br />

COMPRESSOR MUST BE OFF 3 MINUTES TO<br />

ALLOW PRESSURES TO EQUALIZE<br />

BETWEEN HIGH AND LOW SIDE BEFORE<br />

STARTING.<br />

14.WIRE NOT PRESENT IF HPS, LPS, DTS OR<br />

CTD ARE USED.<br />

320848 - 401 REV. A<br />

Fig. 2—<strong>38CM</strong>060 208-230v, 1 Phase, 60 Hertz<br />

A93422<br />

Copyright 1993 CARRIER Corp. • 7310 W. Morris St. • Indianapolis, IN 46231<br />

13165c<br />

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.<br />

Book 1 4 PC 101 Catalog No. 563-781 Printed in U.S.A. Form <strong>38CM</strong>-1W Pg 2 1-94 Replaces: New<br />