19.11.2014 Views

Darrtt Controls Full Linnee Catalog - Dart Controls

Darrtt Controls Full Linnee Catalog - Dart Controls

Darrtt Controls Full Linnee Catalog - Dart Controls

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Tach<br />

MD SERIES SELECTION GUIDE<br />

MODEL MAX. ARM MAX<br />

NUMBER DC AMPS H.P. INPUT OUTPUT<br />

<br />

<br />

MOUNTING SPECIFICATIONS<br />

CONTROLS Page<br />

Ite<br />

Valu<br />

m<br />

4.000"<br />

Tach<br />

ENTER<br />

4.000"<br />

3.622"<br />

MD10P<br />

HOUSING DEPTH<br />

4.625"<br />

0.885"<br />

1.770"<br />

<br />

<br />

1/8 DIN<br />

MICRO-DRIVE<br />

.140" x 2<br />

PANEL CUT-OUT<br />

MD3E <br />

<br />

<br />

<br />

<br />

-Sensor must have minimum output current of 10 mA.<br />

-Drive includes supply for external sensor of 5VDC @50 mA max.<br />

-Shipped set for 0-2400 RPM with one pulse per revolution.<br />

MICRO-DRIVE<br />

CONTROLS<br />

ENTER<br />

.140" x 4<br />

3.622<br />

MD3P<br />

HOUSING DEPTH<br />

4.625"<br />

PANEL CUT-OUT<br />

0.811"<br />

3.622"<br />

2.000"<br />

OPERATING SPECIFICATIONS<br />

Temperature ........................................................... <br />

AC input voltage ........................................................ 85–265 VAC<br />

Input frequency ...............................................................<br />

Overload capacity ............................................ <br />

Transducer signal input ....................................... <br />

...........................................5 VDC, 50mA<br />

DIMENSIONAL SPECIFICATIONS<br />

MODEL WIDTH HEIGHT DEPTH<br />

MD10P inches (millimeters)<br />

Housing 3.620 (91.95) 1.656 (42.06) 4.625 (117.47)<br />

Lens 4.539 (115.29) 2.289 (58.13) 0.375 (9.52)<br />

MD3P inches (millimeters)<br />

Housing 3.620 (91.95) 3.497 (88.82) 4.625 (117.47)<br />

Lens 4.539 (115.29) 4.179 (106.15) 0.375 (9.52)<br />

1/4 DIN<br />

WIRING DIAGRAMS<br />

MD3E<br />

P1-1<br />

P1-2<br />

P1-3<br />

P1-4<br />

P1-5<br />

P1-6<br />

P1-7<br />

P1-8<br />

P1-9<br />

P1-10<br />

P1-11<br />

P1-12<br />

N<br />

L<br />

-A<br />

+A<br />

COM<br />

+5V<br />

S1<br />

S2<br />

NO<br />

C<br />

NC<br />

IN1<br />

-ARM<br />

+ARM<br />

COMMON<br />

+5VDC<br />

SIGNAL<br />

*Jog Input<br />

Ground Lug<br />

AC INPUT<br />

AC INPUT} 85-265VAC<br />

black<br />

red<br />

white<br />

Alarm Output - Normally Open<br />

Alarm Output - Common<br />

Alarm Output - Normally Closed<br />

*INHIBIT<br />

User Input 1<br />

MOTOR<br />

COM (P1-5)<br />

}<br />

Form<br />

* P1-8 & P1-12 user input may be programmed<br />

for a number of functions. Including (jog, inhibit, etc.)<br />

C<br />

Relay Output<br />

(Programmable)<br />

PICK-UP MOUNTED<br />

TO MOTOR SHAFT<br />

(Mounts on rotating<br />

end shaft with 10-32<br />

tapped hole, 1/2" deep)<br />

MOUNTING SPECIFICATIONS MD3E<br />

5.530<br />

Page Item Valu Tach<br />

ENTER<br />

7/32" TYP.<br />

(4 SLOTS)<br />

.350 DEEP<br />

MDP<br />

MASTER<br />

P1-1<br />

P1-2<br />

P1-3<br />

P1-4<br />

P1-5<br />

P1-6<br />

P1-7<br />

P1-8<br />

P1-9<br />

P1-10<br />

P1-11<br />

P1-12<br />

AC INPUT<br />

FUSE<br />

N<br />

MD10P = 7.5 Amp* }85-265VAC<br />

MD3P = 15 Amp*<br />

L<br />

AC INPUT<br />

-A<br />

-ARM<br />

+A<br />

+ARM<br />

MOTOR<br />

COM<br />

COMMON black<br />

+5V<br />

+5VDC red<br />

S1<br />

SIGNAL white<br />

S2<br />

**Jog Input<br />

NO Alarm Output - Normally Open<br />

C Alarm Output - Common<br />

Form C<br />

Relay Output<br />

NC Alarm Output - Normally Closed}<br />

(Programmable)<br />

IN1<br />

User Input 1<br />

**INHIBIT<br />

PICK-UP MOUNTED<br />

TO MOTOR SHAFT<br />

(Mounts on rotating<br />

end shaft with 10-32<br />

tapped hole, 1/2" deep)<br />

COM (P1-5)<br />

black<br />

CONTROLS<br />

* For AC inputs utilizing two hot lines, both inputs should be<br />

protected with appropriately sized fuses or circuit breakers.<br />

** P1-8 & P1-12 user input may be programmed<br />

for a number of functions. Including (jog, inhibit, etc.)<br />

white<br />

7.400<br />

ON<br />

OFF<br />

5.500<br />

.750<br />

MDP<br />

FOLLOWER<br />

P1-1<br />

P1-2<br />

P1-3<br />

P1-4<br />

P1-5<br />

P1-6<br />

P1-7<br />

P1-8<br />

P1-9<br />

P1-10<br />

P1-11<br />

P1-12<br />

N<br />

L<br />

FUSE<br />

MD10P = 7.5 Amp*<br />

MD3P = 15 Amp*<br />

-A<br />

-ARM<br />

+A<br />

+ARM<br />

COM<br />

COMMON<br />

+5V<br />

+5VDC<br />

S1<br />

SIGNAL 1<br />

S2<br />

NO Alarm Output - Normally Open<br />

C Alarm Output - Common<br />

NC Alarm Output - Normally Closed<br />

IN1<br />

User Input 1<br />

**INHIBIT<br />

SIGNAL 2<br />

COM (P1-5)<br />

AC INPUT<br />

}85-265VAC<br />

AC INPUT<br />

}<br />

MOTOR<br />

black<br />

red<br />

white<br />

Form C<br />

Relay Output<br />

(Programmable)<br />

FOLLOWER PICK-UP<br />

MOUNTED TO<br />

MOTOR SHAFT<br />

(Mounts on rotating<br />

end shaft with 10-32<br />

tapped hole, 1/2" deep)<br />

5.125 TYP.<br />

* For AC inputs utilizing two hot lines, both inputs should be<br />

protected with appropriately sized fuses or circuit breakers.<br />

** P1-8 & P1-12 user input may be programmed<br />

for a number of functions. Including (jog, inhibit, etc.)<br />

www.dartcontrols.com<br />

15