ACCU-SET II SERIES ASP20 SELECTION GUIDE<br />

MODEL INPUT DISPLAY UNITS STD. SPEED RANGE<br />

ASP20 120/240 VAC Rate or Time Field Programmable*<br />

Requires <strong>Dart</strong> PU-E or other pick-up.<br />

* Shipped set for 0 - 3600 RPM with one pulse per revolution.<br />

OPERATING SPECIFICATIONS<br />

Temperature .......................................................... <br />

AC input voltage ........................................................ 85–265 VAC<br />

Input frequency ..............................................................<br />

Transducer signal input ....................................... <br />

...........................................5 VDC, 50mA<br />

<br />

MOUNTING SPECIFICATIONS - ASP20<br />

CONTROLS<br />

Page<br />

Item<br />

4.000"<br />

Valu<br />

Tach<br />

MICRO-DRIVE<br />

ACCU-SET II<br />

DIMENSIONAL SPECIFICATIONS<br />

Dia .140" x 2<br />

4.000"<br />

3.622"<br />

ASP20<br />

HOUSING DEPTH<br />

4.625"<br />

PANEL CUT-OUT<br />

.885"<br />

1.770"<br />

MODEL WIDTH HEIGHT DEPTH<br />

ASP20 inches (millimeters)<br />

Housing 3.620 (91.95) 1.656 (42.06) 4.625 (117.47)<br />

Lens 4.539 (115.29) 2.289 (58.13) 0.375 (9.52)<br />

OPTION DESCRIPTION<br />

OPTION<br />

SUFFIX<br />

....................................................<br />

................................................................................<br />

HOOK-UP DIAGRAMS - ASP20<br />

A<br />

S<br />

P<br />

20<br />

M<br />

A<br />

S<br />

T<br />

E<br />

R<br />

A<br />

S<br />

P<br />

20<br />

F<br />

O<br />

L<br />

L<br />

O<br />

W<br />

ER<br />

P1-1<br />

P1-2<br />

P1-3<br />

P1-4<br />

P1-5<br />

P1-6<br />

P1-7<br />

P1-8<br />

P1-9<br />

P1-10<br />

P1-11<br />

P1-12<br />

P1-1<br />

P1-2<br />

P1-3<br />

P1-4<br />

P1-5<br />

P1-6<br />

P1-7<br />

P1-8<br />

P1-9<br />

P1-10<br />

P1-11<br />

P1-12<br />

FUSE<br />

2 Amp<br />

COMMON<br />

+5VDC<br />

SIGNAL 1<br />

SIGNAL 2<br />

UNUSED<br />

UNUSED<br />

UNUSED<br />

HIGH OUT<br />

WIPER OUT<br />

LOW OUT<br />

FUSE<br />

2 Amp<br />

HIGH OUT<br />

WIPER OUT<br />

LOW OUT<br />

COMMON<br />

+5VDC<br />

SIGNAL 1<br />

UNUSED<br />

UNUSED<br />

UNUSED<br />

black<br />

red<br />

white<br />

AC INPUT} AC INPUT<br />

85-265VAC<br />

SIGNAL 2<br />

* OPTIONAL INHIBIT SWITCH<br />

(Open = Inhibit)<br />

(Closed = Run)<br />

AC AC INPUT} 85-265VAC<br />

*<br />

Output<br />

Connection<br />

}See<br />

Note Below<br />

* OPTIONAL INHIBIT<br />

SWITCH<br />

(Open = Run)<br />

(Closed = Inhibit)<br />

Output<br />

Connection<br />

}See<br />

Note Below<br />

*<br />

white<br />

black<br />

red<br />

white<br />

PICK-UP MOUNTED<br />

TO MOTOR SHAFT<br />

(Mounts on rotating<br />

end shaft with 10-32<br />

tapped hole, 1/2" deep)<br />

red<br />

black<br />

FOLLOWER PICK-UP<br />

MOUNTED TO<br />

MOTOR SHAFT<br />

(Mounts on rotating<br />

end shaft with 10-32<br />

tapped hole, 1/2" deep)<br />

MASTER PICK-UP<br />

MOUNTED TO<br />

MOTOR SHAFT<br />

(Mounts on rotating<br />

end shaft with 10-32<br />

tapped hole, 1/2" deep)<br />

OUTPUT CONNECTION NOTE:<br />

<br />

<br />

<br />

<br />

<br />

to the Common terminal (Pot Low) and set Page 7 Item 11 to a<br />

value of 1.<br />

HOOK-UP PROCEDURE:<br />

<br />

<br />

A 2 amp fuse is recommended.<br />

<br />

<br />

driven.<br />

<br />

NOTE: Shielded cable is recommended for applications where<br />

pick-up cord length is in excess of 6 feet.<br />

Connect the shield to the common terminal of the ASP20, leaving<br />

<br />

CAUTION: When pick-up signal is lost, a master ASP20 will run<br />

at full speed, while a follower ASP20 will go to zero speed.<br />

ACCU-SET SERIES CONFIGURATIONS<br />

speed<br />

control<br />

motor<br />

PU-2E<br />

ASP20<br />

speed<br />

control<br />

motor<br />

PU-2E<br />

FEED<br />

REEL<br />

PICK-UP<br />

TAKE UP<br />

REEL<br />

MOTOR<br />

Follower motor as % of master motor speed<br />

ASP20<br />

Constant rate control<br />

SPEED<br />

CONTROL<br />

PU-2E<br />

motor<br />

speed<br />

control<br />

ASP20<br />

ASP20<br />

speed<br />

control<br />

motor<br />

PU-2E<br />

PU-2E<br />

motor<br />

speed ASP20<br />

control<br />

PU-2E<br />

motor<br />

speed<br />

control<br />

ASP20<br />

System for mixing and blending ratio control<br />

Ideal for maintaining precise SCR speed<br />

load regulation<br />

www.dartcontrols.com<br />

25