MD plus SERIES SELECTION GUIDE<br />
MODEL MAX. ARM MAX<br />
NUMBER DC AMPS H.P. INPUT OUTPUT<br />
<br />
<br />
<br />
<br />
<br />
<br />
DIMENSIONS (INCHES)<br />
MODEL WIDTH HEIGHT DEPTH<br />
MD40P (1/8 DIN)<br />
Housing 3.620 1.656 4.625<br />
Lens 4.539 2.289 0.375<br />
MD50P (1/4 DIN)<br />
Housing 3.620 3.497 4.625<br />
Lens 4.539 4.179 0.375<br />
MD50E (NEMA 4 enclosed)<br />
Housing 3.620 3.497 4.625<br />
Lens 4.539 4.179 0.375<br />
APPLICATIONS<br />
The MD plus system is ideal in many process applications<br />
requiring a closed-loop DC variable speed drive with an optional<br />
isolated 4-20mA input and output.<br />
Typical applications include:<br />
• Waste water treatment<br />
• Chemical metering processes<br />
• Laboratory mixing equipment<br />
• Industrial auger/mixing equipment<br />
• Polymer injection processes<br />
OPT420 OPTION<br />
The OPT420 Option may be factory or field installed to any<br />
drive in the MD Plus Series. The 4-20mA output is Loop Powered,<br />
relying on another device in the loop for its power. Both the<br />
4-20mA input and output are individually isolated. A second relay<br />
output is available when this option is used to indicate alarm and<br />
status information.<br />
OPT420 OPTION WIRING DIAGRAM<br />
+<br />
-<br />
+<br />
-<br />
P6<br />
P3<br />
3<br />
2<br />
1<br />
6<br />
5<br />
4<br />
3<br />
2<br />
1<br />
MD50E DRIVE TYPICAL WIRING DIAGRAM<br />
OPT420<br />
SEE<br />
4-20mA HOOK-UP<br />
5A 250V<br />
Form C<br />
}<br />
OPT420 RELAY Output - Common<br />
OPT420 RELAY Output - Normally Open Relay Output<br />
(Programmable)<br />
OPT420 RELAY Output - Normally Closed<br />
Auto / Manual Switch<br />
(Open = Manual)<br />
- 4-20mA In (Black)<br />
WIRING DIAGRAM – MASTER/FOLLOWER<br />
MD plus<br />
MASTER<br />
MD plus<br />
FOLLOWER<br />
P1-1<br />
P1-2<br />
P1-3<br />
P1-4<br />
P1-5<br />
P1-6<br />
P1-7<br />
P1-8<br />
P1-9<br />
P1-10<br />
P1-11<br />
P1-12<br />
MD<br />
MASTER<br />
P1-1<br />
P1-2<br />
P1-3<br />
P1-4<br />
P1-5<br />
P1-6<br />
P1-7<br />
P1-8<br />
P1-9<br />
P1-10<br />
P1-11<br />
P1-12<br />
P1-1<br />
P1-2<br />
P1-3<br />
P1-4<br />
P1-5<br />
P1-6<br />
P1-7<br />
P1-8<br />
P1-9<br />
P1-10<br />
P1-11<br />
P1-12<br />
N<br />
L<br />
-A<br />
+A<br />
COM<br />
+5V<br />
S1<br />
S2<br />
NO<br />
C<br />
NC<br />
IN1<br />
- 4-20mA Out (Black)<br />
-ARM<br />
+ARM<br />
COMMON<br />
+5VDC<br />
SIGNAL<br />
*Jog Input<br />
Ground Lug<br />
-<br />
4-20mA OUT<br />
(White)<br />
4-20mA IN (White)<br />
AC INPUT<br />
AC INPUT} 85-265VAC<br />
MOTOR<br />
black<br />
red<br />
white<br />
Alarm Output - Normally Open<br />
Alarm Output - Common<br />
Alarm Output - Normally Closed<br />
User Input 1<br />
**INHIBIT<br />
COM (P1-5)<br />
* For AC inputs utilizing two hot lines, both inputs should be<br />
protected with appropriately sized fuses or circuit breakers.<br />
** P1-8(S2) & P1-12(IN1) user input may be programmed<br />
for a number of functions, including (jog, inhibit, etc.)<br />
+<br />
+<br />
-<br />
Form C<br />
Relay Output<br />
}(Programmable)<br />
AC INPUT<br />
FUSE<br />
N MD40P = 7.5 Amp* }85-265VAC<br />
MD50P = 15 Amp*<br />
L<br />
AC INPUT<br />
-A<br />
-ARM<br />
+A<br />
+ARM<br />
MOTOR<br />
COM<br />
COMMON black<br />
+5V<br />
+5VDC red<br />
S1<br />
SIGNAL white<br />
S2<br />
**Jog Input<br />
NO Alarm Output - Normally Open<br />
C Alarm Output - Common<br />
Form C<br />
Relay Output<br />
}<br />
NC Alarm Output - Normally Closed (Programmable)<br />
IN1<br />
User Input 1<br />
**INHIBIT<br />
COM (P1-5)<br />
black<br />
white<br />
AC INPUT<br />
FUSE<br />
N MD40P = 7.5 Amp* }85-265VAC<br />
MD50P = 15 Amp*<br />
L<br />
AC INPUT<br />
-A<br />
-ARM<br />
+A<br />
+ARM<br />
MOTOR<br />
COM<br />
COMMON<br />
black<br />
+5V<br />
red<br />
+5VDC<br />
S1<br />
SIGNAL 1<br />
white<br />
S2<br />
SIGNAL 2<br />
NO Alarm Output - Normally Open<br />
C Alarm Output - Common<br />
Form C<br />
Relay Output<br />
NC<br />
}<br />
Alarm Output - Normally Closed (Programmable)<br />
IN1<br />
User Input 1<br />
**INHIBIT<br />
COM (P1-5)<br />
+ -<br />
9-36VDC<br />
EXCITATION<br />
SUPPLY<br />
PICK-UP MOUNTED<br />
TO MOTOR SHAFT<br />
(Mounts on rotating<br />
end shaft with 10-32<br />
tapped hole, 1/2" deep)<br />
CUSTOMER<br />
SUPPLIED<br />
IF NEEDED<br />
PICK-UP MOUNTED<br />
TO MOTOR SHAFT<br />
(Mounts on rotating<br />
end shaft with 10-32<br />
tapped hole, 1/2" deep)<br />
FOLLOWER PICK-UP<br />
MOUNTED TO<br />
MOTOR SHAFT<br />
(Mounts on rotating<br />
end shaft with 10-32<br />
tapped hole, 1/2" deep)<br />
www.dartcontrols.com<br />
17