MD plus SERIES SELECTION GUIDE<br />

MODEL MAX. ARM MAX<br />

NUMBER DC AMPS H.P. INPUT OUTPUT<br />

<br />

<br />

<br />

<br />

<br />

<br />

DIMENSIONS (INCHES)<br />

MODEL WIDTH HEIGHT DEPTH<br />

MD40P (1/8 DIN)<br />

Housing 3.620 1.656 4.625<br />

Lens 4.539 2.289 0.375<br />

MD50P (1/4 DIN)<br />

Housing 3.620 3.497 4.625<br />

Lens 4.539 4.179 0.375<br />

MD50E (NEMA 4 enclosed)<br />

Housing 3.620 3.497 4.625<br />

Lens 4.539 4.179 0.375<br />

APPLICATIONS<br />

The MD plus system is ideal in many process applications<br />

requiring a closed-loop DC variable speed drive with an optional<br />

isolated 4-20mA input and output.<br />

Typical applications include:<br />

• Waste water treatment<br />

• Chemical metering processes<br />

• Laboratory mixing equipment<br />

• Industrial auger/mixing equipment<br />

• Polymer injection processes<br />

OPT420 OPTION<br />

The OPT420 Option may be factory or field installed to any<br />

drive in the MD Plus Series. The 4-20mA output is Loop Powered,<br />

relying on another device in the loop for its power. Both the<br />

4-20mA input and output are individually isolated. A second relay<br />

output is available when this option is used to indicate alarm and<br />

status information.<br />

OPT420 OPTION WIRING DIAGRAM<br />

+<br />

-<br />

+<br />

-<br />

P6<br />

P3<br />

3<br />

2<br />

1<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

MD50E DRIVE TYPICAL WIRING DIAGRAM<br />

OPT420<br />

SEE<br />

4-20mA HOOK-UP<br />

5A 250V<br />

Form C<br />

}<br />

OPT420 RELAY Output - Common<br />

OPT420 RELAY Output - Normally Open Relay Output<br />

(Programmable)<br />

OPT420 RELAY Output - Normally Closed<br />

Auto / Manual Switch<br />

(Open = Manual)<br />

- 4-20mA In (Black)<br />

WIRING DIAGRAM – MASTER/FOLLOWER<br />

MD plus<br />

MASTER<br />

MD plus<br />

FOLLOWER<br />

P1-1<br />

P1-2<br />

P1-3<br />

P1-4<br />

P1-5<br />

P1-6<br />

P1-7<br />

P1-8<br />

P1-9<br />

P1-10<br />

P1-11<br />

P1-12<br />

MD<br />

MASTER<br />

P1-1<br />

P1-2<br />

P1-3<br />

P1-4<br />

P1-5<br />

P1-6<br />

P1-7<br />

P1-8<br />

P1-9<br />

P1-10<br />

P1-11<br />

P1-12<br />

P1-1<br />

P1-2<br />

P1-3<br />

P1-4<br />

P1-5<br />

P1-6<br />

P1-7<br />

P1-8<br />

P1-9<br />

P1-10<br />

P1-11<br />

P1-12<br />

N<br />

L<br />

-A<br />

+A<br />

COM<br />

+5V<br />

S1<br />

S2<br />

NO<br />

C<br />

NC<br />

IN1<br />

- 4-20mA Out (Black)<br />

-ARM<br />

+ARM<br />

COMMON<br />

+5VDC<br />

SIGNAL<br />

*Jog Input<br />

Ground Lug<br />

-<br />

4-20mA OUT<br />

(White)<br />

4-20mA IN (White)<br />

AC INPUT<br />

AC INPUT} 85-265VAC<br />

MOTOR<br />

black<br />

red<br />

white<br />

Alarm Output - Normally Open<br />

Alarm Output - Common<br />

Alarm Output - Normally Closed<br />

User Input 1<br />

**INHIBIT<br />

COM (P1-5)<br />

* For AC inputs utilizing two hot lines, both inputs should be<br />

protected with appropriately sized fuses or circuit breakers.<br />

** P1-8(S2) & P1-12(IN1) user input may be programmed<br />

for a number of functions, including (jog, inhibit, etc.)<br />

+<br />

+<br />

-<br />

Form C<br />

Relay Output<br />

}(Programmable)<br />

AC INPUT<br />

FUSE<br />

N MD40P = 7.5 Amp* }85-265VAC<br />

MD50P = 15 Amp*<br />

L<br />

AC INPUT<br />

-A<br />

-ARM<br />

+A<br />

+ARM<br />

MOTOR<br />

COM<br />

COMMON black<br />

+5V<br />

+5VDC red<br />

S1<br />

SIGNAL white<br />

S2<br />

**Jog Input<br />

NO Alarm Output - Normally Open<br />

C Alarm Output - Common<br />

Form C<br />

Relay Output<br />

}<br />

NC Alarm Output - Normally Closed (Programmable)<br />

IN1<br />

User Input 1<br />

**INHIBIT<br />

COM (P1-5)<br />

black<br />

white<br />

AC INPUT<br />

FUSE<br />

N MD40P = 7.5 Amp* }85-265VAC<br />

MD50P = 15 Amp*<br />

L<br />

AC INPUT<br />

-A<br />

-ARM<br />

+A<br />

+ARM<br />

MOTOR<br />

COM<br />

COMMON<br />

black<br />

+5V<br />

red<br />

+5VDC<br />

S1<br />

SIGNAL 1<br />

white<br />

S2<br />

SIGNAL 2<br />

NO Alarm Output - Normally Open<br />

C Alarm Output - Common<br />

Form C<br />

Relay Output<br />

NC<br />

}<br />

Alarm Output - Normally Closed (Programmable)<br />

IN1<br />

User Input 1<br />

**INHIBIT<br />

COM (P1-5)<br />

+ -<br />

9-36VDC<br />

EXCITATION<br />

SUPPLY<br />

PICK-UP MOUNTED<br />

TO MOTOR SHAFT<br />

(Mounts on rotating<br />

end shaft with 10-32<br />

tapped hole, 1/2" deep)<br />

CUSTOMER<br />

SUPPLIED<br />

IF NEEDED<br />

PICK-UP MOUNTED<br />

TO MOTOR SHAFT<br />

(Mounts on rotating<br />

end shaft with 10-32<br />

tapped hole, 1/2" deep)<br />

FOLLOWER PICK-UP<br />

MOUNTED TO<br />

MOTOR SHAFT<br />

(Mounts on rotating<br />

end shaft with 10-32<br />

tapped hole, 1/2" deep)<br />

www.dartcontrols.com<br />