Level sensors, summary<br />
The advantages of the angle sensor are the<br />
proportional measurement process along<br />
with their contact-free and therefore wearfree<br />
operation.<br />
The generation of ratios (proportional<br />
measurement) means that the output signal<br />
proportional to the angle is largely<br />
independent of mechanical tolerances such<br />
as distance changes, axle movement or<br />
inclination errors. Magnetic interference is<br />
also largely suppressed due to the generation<br />
of ratios.<br />
As no magnetic materials are required,<br />
temperature and age cause only minimal<br />
variances in the measured values. Such<br />
variances are caused by a reduction in the<br />
strength of the magnetic field of permanent<br />
magnets over time or due to temperature<br />
changes.<br />
Warning lamp K134...<br />
... illuminates for one second when<br />
terminal 15 is ON (self-test).<br />
Warning lamp K134<br />
... is constantly illuminated in the<br />
case of relevant <strong>system</strong> errors or<br />
when the <strong>system</strong> is switched off.<br />
... is constantly illuminated during<br />
basic <strong>system</strong> setting and when<br />
basic <strong>system</strong> setting has not been<br />
performed successfully.<br />
... flashes in the case of extremely<br />
low or high <strong>level</strong>s.<br />
... flashes during final control<br />
diagnosis.<br />