3 Determine if Bottom Latch Retraction Adjustment is<br />

Required.<br />

For 2-Point Latch Only<br />

4 Adjust Bottom Latch Retraction (if necessary).<br />

For 2-Point Latch Only<br />

a. Throughout this<br />

adjustment<br />

process, hold<br />

bottom latch<br />

alongside top<br />

latch to simulate<br />

the installed<br />

condition of the<br />

latches.<br />

b. To determine whether an<br />

adjustment is required, actuate<br />

the top latch to the hold-open<br />

position by pressing down on the<br />

connecting rod. Bottom latch<br />

should retract to within ¹⁄₁₆" of<br />

flush. If it does not, an adjustment<br />

is necessary.<br />

press<br />

If no adjustment is<br />

needed, proceed<br />

to Step 5.<br />

¹⁄₁₆"<br />

a. Before proceeding,<br />

return the top latch to<br />

the latched position by<br />

pulling in the direction<br />

shown.<br />

b. Secure the snap-fitting with a<br />

³⁄₈" wrench while loosening the<br />

locknut with a 10mm wrench.<br />

³⁄₈"<br />

top latch<br />

e. While securing the snap-fitting<br />

with a ³⁄₈" wrench, continue to<br />

tighten the locknut until it is<br />

secure.<br />

10mm<br />

snapfitting<br />

³⁄₈"<br />

flush<br />

top latch<br />

(hold-open<br />

position)<br />

bottom latch<br />

(retracted)<br />

lock nut<br />

10mm<br />

f. Actuate the top latch to the<br />

hold-open position to confirm<br />

that the bottom latch is secure<br />

and now retracts to within ¹⁄₁₆"<br />

of flush.<br />

c. Rotate the snap-fitting by hand<br />

until the slack is taken up. Do<br />

not overtighten.<br />

press<br />

¹⁄₁₆"<br />

flush<br />

snap-fitting<br />

top latch<br />

(hold-open<br />

position)<br />

bottom latch<br />

(retracted)<br />

d. Close the gap between the<br />

locknut and snap-fitting by<br />

turning the locknut in a<br />

clockwise direction using a<br />

10mm wrench while holding the<br />

conduit cap with the ³⁄₈" wrench.<br />

Stop when the gap is closed<br />

and the snap-fitting begins to<br />

turn with the locknut.<br />

10mm<br />

conduit<br />

cap<br />

³⁄₈"<br />

3