MSDS - McGean
MSDS - McGean
MSDS - McGean
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>McGean</strong>-Rohco, Inc.<br />
2910 Harvard Avenue<br />
Cleveland, Ohio 44105-3010 USA<br />
Phone: 216-441-4900 Fax: 216-441-1377<br />
www.mcgean.com<br />
MATERIAL SAFETY DATA SHEET<br />
23054<br />
© 2014 <strong>McGean</strong>-Rohco, Inc. PAGE 1 OF 4<br />
PRODUCT NAME: CEE-BEE A-477 <strong>MSDS</strong> No.: 23054<br />
REVISION: 6<br />
PREPARED BY: DIR ENV AFFAIRS ISSUE DATE:08/01/83 EFFECTIVE DATE: 06/20/13<br />
--------------------------------------------------------------------------------<br />
SECTION A. MATERIAL IDENTIFICATION.<br />
MANUFACTURER: McGEAN-ROHCO, INC.<br />
CHEMTREC:<br />
TELEPHONE #: 800-424-9300<br />
38521 SCHOOLCRAFT AVE. OR 703-527-3887<br />
LIVONIA MI 48150<br />
TELEPHONE: 216-441-4900<br />
--------------------------------------------------------------------------------<br />
SECTION B. INGREDIENTS AND HAZARDS.<br />
INGREDIENT: MONOETHANOLAMINE<br />
40.0 - 50.0%<br />
CAS NUMBER: 141-43-5<br />
EXPOSURE LIMIT: TWA: 8mg/CUBIC METER<br />
SUSPECT CARCINOGEN: NO<br />
--------------------------------------------------------------------------------<br />
SECTION C. PHYSICAL DATA.<br />
APPEARANCE: 2-PHASE STRAW COLORED LIQUID BOILING POINT: 280-320F*<br />
ODOR: AMINE<br />
FREEZING POINT: -4F*<br />
SPECIFIC GRAVITY: 1.05*<br />
VAPOR PRESSURE: 0.2-.3*mmHg-20C<br />
pH: 12-13* VAPOR DENSITY: AIR = 1: >1<br />
% VOLATILE BY VOLUME: *92<br />
EVAPORATION RATE:
<strong>McGean</strong>-Rohco, Inc.<br />
2910 Harvard Avenue<br />
Cleveland, Ohio 44105-3010 USA<br />
Phone: 216-441-4900 Fax: 216-441-1377<br />
www.mcgean.com<br />
MATERIAL SAFETY DATA SHEET<br />
23054<br />
© 2014 <strong>McGean</strong>-Rohco, Inc. PAGE 2 OF 4<br />
UNUSUAL FIRE OR NONE KNOWN.<br />
EXPLOSION HAZARDS:<br />
--------------------------------------------------------------------------------<br />
SECTION E. REACTIVITY DATA<br />
MATERIAL IS STABLE.<br />
HAZARDOUS POLYMERIZATION WILL NOT OCCUR.<br />
CONDITIONS TO<br />
AVOID:<br />
INCOMPATIBILITY<br />
MATERIALS TO AVOID:<br />
NA<br />
STRONG OXIDIZERS,ACIDS.<br />
HAZARDOUS DECOMPOSITION OXIDES OF CARBON AND NITROGEN.<br />
PRODUCTS:<br />
--------------------------------------------------------------------------------<br />
SECTION F. HEALTH HAZARD DATA.<br />
SUMMARY OF RISKS:<br />
MEDICAL CONDITIONS<br />
WHICH MAY BE<br />
AGGRAVATED BY CONTACT:<br />
TARGET ORGANS:<br />
SARA-ACUTE & CHRONIC<br />
DERMATITIS.<br />
SKIN,EYES,LIVER,KIDNEYS.<br />
PRIMARY ENTRY ROUTES: THROUGH CONTACT AND INHALATION OF VAPORS.<br />
ACUTE EFFECTS:<br />
CHRONIC EFFECTS:<br />
CORROSIVE TO SKIN AND EYES.<br />
IRRITATING TO RESPIRATORY SYSTEM.<br />
AFFECT TARGET ORGANS.<br />
SIGNS & SYMPTOMS OF OVEREXPOSURE:<br />
EYE CONTACT: BURNING SENSATION.<br />
SKIN CONTACT: STINGING OR BURNING SENSATION.<br />
INHALATION:<br />
INGESTION:<br />
DIZZINESS,HEADACHE. EXPOSURE OF THIS NATURE UNLIKELY BECAUSE<br />
OF ODOR.<br />
IRRITATION OR BURNING OF MOUTH AND THROAT.
<strong>McGean</strong>-Rohco, Inc.<br />
2910 Harvard Avenue<br />
Cleveland, Ohio 44105-3010 USA<br />
Phone: 216-441-4900 Fax: 216-441-1377<br />
www.mcgean.com<br />
MATERIAL SAFETY DATA SHEET<br />
23054<br />
© 2014 <strong>McGean</strong>-Rohco, Inc. PAGE 3 OF 4<br />
EMERGENCY & FIRST AID PROCEDURES:<br />
EYE CONTACT: FLUSH WITH WATER FOR 15 MINUTES. GET MEDICAL ATTENTION.<br />
IF ANY SYMPTOMS OCCUR,GET MEDICAL ATTENTION.<br />
INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING,GIVE ARTIFICIAL<br />
RESPIRATION. IF BREATHING IS DIFFICULT,GIVE OXYGEN. GET MEDICAL<br />
ATTENTION.<br />
INGESTION: IF CONSCIOUS, GIVE TWO GLASSES OF WATER TO DILUTE. DO NOT<br />
INDUCE VOMITING. GET MEDICAL ATTENTION.<br />
--------------------------------------------------------------------------------<br />
SECTION G. SPILL, LEAK AND DISPOSAL PROCEDURES.<br />
SPILL/LEAK SOAK UP WITH SAWDUST,SAND OR OTHER ABSORBANT MATERIAL.<br />
PROCEDURES: FLUSH AREA WITH WATER.<br />
WASTE<br />
MANAGEMENT<br />
& DISPOSAL<br />
PROCEDURES:<br />
SEND TO AN APPROVED WASTE DISPOSAL FACILITY.<br />
FOLLOW ALL LOCAL,STATE,AND FEDERAL REGULATIONS.<br />
RCRA # (IF DISPOSED AS RECEIVED): D002<br />
--------------------------------------------------------------------------------<br />
SECTION H. SPECIAL PROTECTION INFORMATION<br />
PERSONAL PROTECTIVE EQUIPMENT:<br />
GOGGLES: CHEMICAL GOGGLES.<br />
GLOVES: NEOPRENE OR POLYETHYLENE.<br />
RESPIRATOR: IF TWA IS EXCEEDED, MUST BE NIOSH OR MSHA APPROVED.<br />
OTHER:<br />
SUFFICIENT TO PREVENT SKIN CONTACT.<br />
WORKPLACE CONSIDERATIONS:<br />
VENTILATION: SUFFICIENT TO KEEP BELOW TWA LIMIT.<br />
SAFETY STATIONS: EYE WASH.<br />
OTHER:<br />
SAFETY SHOWER.<br />
--------------------------------------------------------------------------------<br />
SECTION I. SPECIAL PRECAUTIONS
<strong>McGean</strong>-Rohco, Inc.<br />
2910 Harvard Avenue<br />
Cleveland, Ohio 44105-3010 USA<br />
Phone: 216-441-4900 Fax: 216-441-1377<br />
www.mcgean.com<br />
MATERIAL SAFETY DATA SHEET<br />
23054<br />
© 2014 <strong>McGean</strong>-Rohco, Inc. PAGE 4 OF 4<br />
SPECIAL HANDLING STORE INSIDE @ 32-90F IN WELL VENTILATED AREA.<br />
& STORAGE PROCEDURES: KEEP CONTAINERS TIGHTLY CLOSED.<br />
D.O.T. CLASS 8 UN REGISTER: UN-2491<br />
IMDG CLASS: 8 UN REGISTER: UN-2491<br />
IATA CLASS: 8 UN REGISTER: UN-2491<br />
--------------------------------------------------------------------------------<br />
EXPLANATION OF SYMBOLS<br />
NA = NOT APPLICABLE<br />
UK = UNKNOWN<br />
--------------------------------------------------------------------------------<br />
THIS MATERIAL SAFETY DATA SHEET IS OFFERED SOLELY FOR YOUR INFORMATION,<br />
CONSIDERATION, AND INVESTIGATION. WHILE THE INFORMATION AND RECOMMENDATIONS<br />
SET FORTH HEREIN ARE BELIEVED TO BE ACCURATE AS OF THE DATE HEREOF,<br />
McGEAN-ROHCO, INC. MAKES NO WARRANTY WITH RESPECT THERETO AND DISCLAIMS ALL<br />
LIABILITY FROM RELIANCE THEREON.<br />
THIS MATERIAL SAFETY DATA SHEET HAS BEEN PREPARED TO COMPLY WITH<br />
TITLE 29 CODE OF FEDERAL REGULATIONS, PART 1910.1200, OSHA HAZARD<br />
COMMUNICATION STANDARD, AND TO FULFILL THE ANNUAL CHEMICAL NOTIFICATION<br />
REQUIREMENTS OF SARA TITLE III, SECTION 313.