25.12.2014 Views

EWP Hangers - USP Connectors

EWP Hangers - USP Connectors

EWP Hangers - USP Connectors

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Product Catalog<br />

57 th Edition


Table of Contents<br />

Corrosion Information ............7-8<br />

Design Notes ..................11<br />

Installation Notes ...............12<br />

Product Information ................9<br />

Product Notes .................10<br />

Reference Number Index .........6<br />

<strong>USP</strong> Index ................... 4-5<br />

Fasteners<br />

Section Overview .............13<br />

Bearing Plates .................20<br />

Nails. . . . . . . . . . . . . . . . . . . . . . 14-15<br />

Wood Screws .............. 16-19<br />

LumberLok Screws ..............20<br />

Concrete & Masonry <strong>Connectors</strong><br />

Section Overview .......... 21-22<br />

Mechanical & Adhesive Anchors ......<br />

. . . . . . . ................... 23-26<br />

Anchor Bolts ............... 31-33<br />

Concrete Form Ties & Wedge. . . . . 30<br />

Foundation Anchors ......... 33-35<br />

Laminated Beam Seats ..........36<br />

Masonry Metals ............. 27-29<br />

Adjustable Support Posts ..... 37-39<br />

Holdowns<br />

Section Overview .............40<br />

Concrete Angles ...............46<br />

Foundation Straps ........... 46-49<br />

Holdowns .................. 41-44<br />

Purlin Anchors .................50<br />

Tension Ties ..................45<br />

Caps & Bases<br />

Section Overview .............51<br />

Column Bases .............. 55-56<br />

Column Caps ............... 60-63<br />

Composite Post Bases ..........59<br />

Elevated Post Bases ............54<br />

Post Anchors ...............52, 55<br />

Post Caps ................. 57-59<br />

Wet Post Anchors ..............53<br />

Angles & Straps<br />

Section Overview .......... 64-65<br />

Coiled Strapping ...............76<br />

Framing Clips .................75<br />

Framing Plates & Angles .... . .66-70, .<br />

72-73<br />

Header <strong>Hangers</strong> ...............75<br />

Lateral Joist <strong>Connectors</strong> .........72<br />

Masonry Straps ............. 84-85<br />

Ornamental <strong>Connectors</strong> .........74<br />

Straps .................74, 77-80<br />

Stud Plate Ties ................71<br />

Twist Straps ................81 -82<br />

Wood Foundation Straps. . . . . . . . . 83<br />

<strong>Hangers</strong><br />

Section Overview .......... 86-87<br />

Face Mount <strong>Hangers</strong> ......... 88-96<br />

Hanger Selector Guide ..........87<br />

Masonry <strong>Hangers</strong> ......... 106-109<br />

Top Mount <strong>Hangers</strong>. . . . . . . . . 97-102<br />

Slope & Skew <strong>Hangers</strong> ..... 103-105<br />

Panel & Purlin <strong>Hangers</strong> ..... 110-112<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Section Overview ........ 113-115<br />

Adjustable <strong>Connectors</strong> .........143<br />

<strong>EWP</strong> Hanger Selector Guide ....113<br />

<strong>EWP</strong> Installation Guide ..... 116-117<br />

Face Mount <strong>Hangers</strong> ....... 118-123<br />

Glulam <strong>Hangers</strong> .......... 145-150<br />

Slope/Skew <strong>Hangers</strong> ...........144<br />

Top Mount <strong>Hangers</strong>. . . . . . . . 124-14 2<br />

Truss & Rafter Tiedowns<br />

Section Overview ............151<br />

Truss Anchors ................152<br />

Girder Tiedowns .......... 154-156<br />

Hurricane Gusset Angles .......158<br />

Rafter Ties ............... 160-162<br />

Moisture Barrier Plates .........152<br />

Uplift Girder Ties ..............153<br />

Hurricane Retro-Fit Connector ....159<br />

Masonry Uplift Connector .......157<br />

Plated Truss<br />

Section Overview ........ 163-164<br />

Alternate Installations ..........182<br />

Blocking Supports .............179<br />

Drag Strut <strong>Connectors</strong>. . . . . . . . . . 181<br />

Girder Truss <strong>Hangers</strong> ...... 174-176<br />

Hip/Jack <strong>Connectors</strong> ....... 172-173<br />

Roof Truss Ties ...............179<br />

Skewed Truss <strong>Hangers</strong> ..... 170-171<br />

Supplemental Bearing Plates ....178<br />

Truss Clips .............. 176-177<br />

Truss <strong>Hangers</strong> ............ 165-169<br />

Truss Spacers ............ 180-181<br />

Miscellaneous<br />

Angles ......................201<br />

Bolt Down ...................189<br />

Bridging ................. 183-184<br />

Closet Rods ..................202<br />

Concealed Stringer Hanger ......194<br />

Corner Tie ...................204<br />

Deck Clip ....................185<br />

Deck Ties ...................193<br />

Deck Tie Back ................192<br />

Drywall Clip ..................197<br />

Fence Brackets ...............190<br />

Fence Post <strong>Connectors</strong> .........188<br />

Fence Rail Hanger ............196<br />

Hardy Frame ............. 206-209<br />

Insulation Supports ............203<br />

Mending Plates ...............198<br />

Nail Plates ...................198<br />

Pipe Rail Ties ................191<br />

Plastic Post Caps .............204<br />

Plywood Clips ................197<br />

Protection Plates ..............186<br />

Ridge Rafter .................199<br />

Shelf Brackets ................203<br />

Stair Angles ..................195<br />

Step Flashing ................196<br />

Stud Shoes ..................189<br />

Tough Tie Products ........ 199-200<br />

Wall Bracing .................187<br />

Wall Ties ....................201<br />

Manufactured Housing .......205<br />

Lateral Systems ......... 206-209<br />

Specialty Options ............210-213<br />

Corrosion Resistant Products ..<br />

. . . . . . . . . . . . . . . . . . . . . . . . 214-215<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

WARRANTY<br />

MiTek USA, Inc. (“MiTek”) warrants its <strong>USP</strong> catalog Products to be free from material<br />

defects in manufacture and design, and further warrants that they will perform within the<br />

design limitations of its published building code approvals for the applications described,<br />

when properly installed and maintained. These warranties do not cover Product<br />

deterioration due to environmental conditions, Products that have be modified or damaged,<br />

improperly installed or used outside of published design limitations or for other applications.<br />

In the event any Product is shown to not conform to these warranties, <strong>USP</strong>’s sole<br />

obligation, and Customer’s sole and exclusive remedy, shall be, at <strong>USP</strong>’s option, to replace<br />

the non-conforming product or refund the full purchase price paid by Customer to <strong>USP</strong><br />

therefor. <strong>USP</strong> MAKES NO OTHER PRODUCT WARRANTIES, EXPRESS OR IMPLIED,<br />

OF ANY KIND, AND PARTICULARLY EXCLUDES ANY IMPLIED WARRANTY OR<br />

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT<br />

SHALL <strong>USP</strong> BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES,<br />

REGARDLESS OF THE LEGAL THEORY OF RECOVERY, EVEN IF IT WAS AWARE OF<br />

THE POSSIBILITY OF SUCH DAMAGES. IN ANY CASE, <strong>USP</strong>’s MAXIMUM LIABILITY<br />

SHALL NOT EXCEED THE PURCHASE PRICE PAID BY CUSTOMER FOR THE NON-<br />

CONFORMING PRODUCT. Some states restrict consequential or other liability damage<br />

limitations, so some of the above limitations may not apply to you. MiTek reserves the right<br />

to change this warranty periodically. Consult MiTek’s website www.uspconnectors.com or<br />

contact MiTek for a current warranty statement.<br />

2<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


The Original Connector Company!<br />

<br />

HARDY<br />

FRAME ®<br />

United Steel Products (<strong>USP</strong>) is the leading<br />

manufacturer of structural connectors and<br />

hardware for the building industry. Our legacy<br />

of innovation dates back to 1933 when the original<br />

timber connectors were conceived and standardized.<br />

Over the years <strong>USP</strong> has grown by combining some<br />

of the most innovative and recognizable structural<br />

brands into one “UNITED” company that spans<br />

the world. Our lineage includes such brand names<br />

as Teco ® , Silver, Lumberlok, Kant-Sag ® ,<br />

Hughes, SEMCO, Covert, and Renown.<br />

As of March, 2011 <strong>USP</strong> has been a part of MiTek<br />

Industries, Inc., which is a subsidiary of Warren Buffet’s<br />

Berkshire Hathaway. Since, <strong>USP</strong> has expanded<br />

its product offering to include the following leading<br />

brands: Hardy Frame ® shear wall system, Zone4 ®<br />

Tie-down system, and Sapphire software suite.<br />

With our rich heritage and solid DNA combined with<br />

MiTek’s extensive resources and unmatched software<br />

expertise, <strong>USP</strong> has become “the connector of choice<br />

for the building industry”.<br />

Give your customers a choice!<br />

Specify the Original - Specify <strong>USP</strong>!<br />

Better Technology. Better Building.<br />

A Berkshire Hathaway Company


<strong>USP</strong> Index<br />

*<br />

A3 Angle Clip . . . . . . . . . . . . . . . .69-70<br />

AB Anchor Bolts . . . . . . . . . . . . . . . .33<br />

ABP Anchor Bolts . . . . . . . . . . . . . . .33<br />

ABS12 Anchor Bolt Stabber . . . . . . .28<br />

AC Angle Clips . . . . . . . . . . . . . . .69-70<br />

Alternate Installations . . . . . . . . . .182<br />

ANJ44S Heavy Angles . . . . . . . . . . .72<br />

APB Post Base . . . . . . . . . . . . . . . . .54<br />

B Corner Reinforcements . . . . . . . . .73<br />

BC Post Caps . . . . . . . . . . . . . . . . . .58<br />

BD Bolt Down . . . . . . . . . . . . . . . . .189<br />

BL Corner Reinforcements . . . . . . . .73<br />

BN Breakfast Nook <strong>Hangers</strong> . . . . . .172<br />

BP Bearing Plates . . . . . . . . . . . . . . .20<br />

BPH Beam & Purlin <strong>Hangers</strong> . . . . . . . .<br />

. .124-125, 128-129, 132-136, 138-142<br />

C Post Caps . . . . . . . . . . . . . . . . . . . .58<br />

CBE Column Bases . . . . . . . . . . . . . .56<br />

CBSQ Column Bases . . . . . . . . . . . .55<br />

CMST Coiled Strapping . . . . . . . . . . .76<br />

CMSTC16 Coiled Strapping . . . . . . .76<br />

Corrosion Information . . . . . . . . . .7-8<br />

Corrosion Resistant Products 214-215<br />

CPB Composite Post Bases . . . . . . .59<br />

CR Concrete Reinforcing Rods . . . . .27<br />

CRE24 Coated Rebar . . . . . . . . . . . .29<br />

CRW Closet Rods . . . . . . . . . . . . . .202<br />

CRWFP Fluted Closet Rods . . . . . .202<br />

CRZ Closet Rods . . . . . . . . . . . . . . .202<br />

CRZFP Fluted Closet Rods . . . . . . .202<br />

CSH-TZ Concealed Stringer Hanger . . .<br />

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .194<br />

D Post Anchors . . . . . . . . . . . . . . . . .55<br />

DC1 Drywall Clip . . . . . . . . . . . . . . .197<br />

DC50 Deck Clip . . . . . . . . . . . . . . .185<br />

DSC4 Drag Strut Connector . . . . . .181<br />

DT Standard Joist Hanger . . . . . .88, 92<br />

DTB Deck Tie Bracket . . . . . . . . . . .192<br />

DTUS Undersaddle <strong>Hangers</strong> . . . . . .111<br />

DUC Ductile Undercut Anchors . . . . .25<br />

EA Adhesive (CIA-EA) . . . . . . . . . . .24<br />

EBG44 Elevated Post Base . . . . . . .54<br />

EPB Elevated Post Bases . . . . . . . . .54<br />

EPBH Elevated Post Bases . . . . . . .54<br />

EPCM End Post Caps . . . . . . . . . . . .57<br />

ERB24 Fence Bracket . . . . . . . . . . .190<br />

<strong>EWP</strong> Hanger Selector Guide . . . . .113<br />

<strong>EWP</strong> Installation . . . . . . . . . . .116-117<br />

FA3 Foundation Anchors . . . . . . . . . .34<br />

FB Fence Brackets . . . . . . . . . . . . .190<br />

FC Fence Brackets . . . . . . . . . . . . .190<br />

FHD26 Panel Hanger . . . . . . . . . . . .110<br />

FPH24-TZ Fence Rail Hanger . . . . .196<br />

FRB Fence Brackets . . . . . . . . . . . .190<br />

FT Concrete Form Ties . . . . . . . . . . .30<br />

FTC Floor Truss Clips . . . . . . . . . . .177<br />

*<br />

GEL Epoxy (CIA-GEL Series) . . . . .23<br />

GHF Glulam Face Mount <strong>Hangers</strong> .146<br />

GT Girder Truss <strong>Hangers</strong> . . . . .174-175<br />

GTD Girder Truss <strong>Hangers</strong> . . .174-175<br />

* GTQ/GTQM Girder Truss <strong>Hangers</strong> .176<br />

GTS Girder Truss <strong>Hangers</strong> . . . .174-175<br />

GTWS Girder Truss <strong>Hangers</strong> . . . . .175<br />

Hanger Selector Guide . . . . . . . . . .87<br />

HBPS Bearing Plates . . . . . . . . . . . . 20<br />

HC520 Hurricane/Seismic Anchor160,162<br />

* HCPRS Rafter Ties . . . . . . . . .160, 162<br />

HD Face Mount <strong>Hangers</strong> . . . . . . . . . . . .<br />

. . . . . . . . . . . . . . . .90-96, 118, 122-123<br />

HDO Top Mount <strong>Hangers</strong> . . .97, 99-101<br />

HDQIF Inverted Flange <strong>Hangers</strong> . . . . . .<br />

. . . . . . . . . . . . . . . .90, 92-96, 119, 123<br />

* HFX Hardy Frame Panels & Brace<br />

Frames . . . . . . . . . . . . . . . . . . . . .206<br />

HGA Hurricane Gusset Angles . . . .158<br />

* HGU Girder <strong>Hangers</strong> . . . . . . . . . . . 145<br />

HH Header <strong>Hangers</strong> . . . . . . . . . . . . .75<br />

HHC Hip/Hip <strong>Connectors</strong> . . . . . . . . .173<br />

HHCP2 Hurricane/Seismic Anchor . . . .<br />

. . . . . . . . . . . . . . . . . . . . . . . . .160,162<br />

HJC Hip/Jack <strong>Connectors</strong> . . . . . . . .173<br />

HJHC Hip/Jack <strong>Connectors</strong> . . . . . . .173<br />

HL Light Gauge Purlin <strong>Hangers</strong> . .98-99<br />

HLBH Beam <strong>Hangers</strong> . . . . . . . . . . . . . .<br />

. . . . . . . . . . . . .126, 132-136, 138-142<br />

*<br />

*<br />

HPAHD Foundation Straps . . . . . .48-49<br />

HRS Strap Ties . . . . . . . . . . . . . .77, 79<br />

HTC4 Heavy Truss Clip . . . . . . . . . .179<br />

HTHJ Hip/Jack <strong>Connectors</strong> . . . . . . 173<br />

*<br />

HTP Strap Ties . . . . . . . . . . . . . . .77-78<br />

HTT Tension Ties . . . . . . . . . . . . . . . .45<br />

HTW Twist Straps . . . . . . . . . . . . .81-82<br />

HTWM Twist Straps . . . . . . . . . . . . . .85<br />

HUGT Girder Tiedowns . . . . . . . . . 156<br />

HUS Slant Nail <strong>Hangers</strong> . . . . . . . . . . . .<br />

. . . . . . . . . . . . .89, 91-95, 119, 123,167<br />

HWUH Top Flange <strong>Hangers</strong> . . 106-107<br />

ICPL Protection Plates . . . . . . . . . .186<br />

IS Insulation Supports . . . . . . . . . . .203<br />

JA Framing Angles . . . . . . . . . . . .69-70<br />

JDS Purlin <strong>Hangers</strong> . . . . . . . . . . . . .112<br />

JH Multi-Purpose Joist <strong>Hangers</strong> . . .102<br />

JL Standard Joist <strong>Hangers</strong> . . . . .88, 91<br />

JLIF Inverted Flange <strong>Hangers</strong> . .88, 91<br />

JN Power Nail <strong>Hangers</strong> . . . . . . . . . .205<br />

JN(E) Power Nail <strong>Hangers</strong> . . . . . . .205<br />

JNP Mending Plates . . . . . . . . . . . .198<br />

JP Adjustable Support Post . . . . . . . .37<br />

JPF Purlin <strong>Hangers</strong> . . . . . . . . . . . . .110<br />

JUS Slant Nail Joist <strong>Hangers</strong> .89, 91-95<br />

KB Hanger . . . . . . . . . . . . .97, 100-101<br />

KCBQ Column Bases . . . . . . . . . . . .56<br />

*<br />

*<br />

*<br />

*<br />

*<br />

KCCQ Column Caps . . . . . . . . . .60-63<br />

KECCQ End Column Caps . . . . .60-63<br />

KEG Glulam Beam <strong>Hangers</strong> . . . . . .147<br />

KGB Glulam <strong>Hangers</strong> . . . . . . . . . . .148<br />

KGLB Laminated Beam Seats . . . . .36<br />

KGLBT Laminated Beam Seats . . . .36<br />

KGLS Glulam Saddle <strong>Hangers</strong> . . . 150<br />

KGLST Glulam Saddle <strong>Hangers</strong> . . .150<br />

KGLT Glulam Beam <strong>Hangers</strong> . . . . .149<br />

KHGB Glulam <strong>Hangers</strong> . . . . . . . . . .148<br />

KHGLB Laminated Beam Seats . . . .36<br />

KHGLS Glulam Saddle <strong>Hangers</strong> . . .150<br />

KHGLST Glulam Saddle <strong>Hangers</strong> . .150<br />

KHGLT Glulam Beam <strong>Hangers</strong> . . . 149<br />

KHHB Glulam <strong>Hangers</strong> . . . . . . . . . .148<br />

KHL Corner Framing Angle . . . . . . . .73<br />

KHW Top Flange <strong>Hangers</strong> .98, 100-101<br />

KLB Hanger . . . . . . . . . . . . . . . . .97, 99<br />

KLEG Glulam Beam <strong>Hangers</strong> . . . . .147<br />

KMEG Glulam Beam <strong>Hangers</strong> . . . .147<br />

KNS1 Protection Plate . . . . . . . . . . .186<br />

KRPS Strap Ties . . . . . . . . . . . . . . . .80<br />

KSCT68 Corner Tie . . . . . . . . . . . . .204<br />

KST Strap Ties . . . . . . . . . . . . . . .77-79<br />

KSTI Strap Ties . . . . . . . . . . . . . .77, 79<br />

KTS Twist Straps . . . . . . . . . . . . .81-82<br />

L Straps . . . . . . . . . . . . . . . . . . . . . . .74<br />

LH Strap . . . . . . . . . . . . . . . . . . . . . . .74<br />

LL LumberLok Screws . . . . . . . . . . . .20<br />

LBP Bearing Plates . . . . . . . . . . . . . .20<br />

LBPS Bearing Plates . . . . . . . . . . . . .20<br />

LDSC4 Drag Strut Connector . . . . .181<br />

LFTA6 Twist Strap . . . .81-82, 160, 162<br />

LGU Girder <strong>Hangers</strong> . . . . . . . . . . . 145<br />

LJC-TZ Lateral Joist Connector . . . . 72<br />

LJQ Lateral Joist Connector . . . . . . . 72<br />

LPTA Embedded Truss Anchors . . 152<br />

LS Light Slope <strong>Hangers</strong> . . . . . . . . .105<br />

LSSH Slope/Skew <strong>Hangers</strong> . .103, 144<br />

LSTA Strap Ties . . . . . . . . . . . . . .77-78<br />

LSTAD Foundation Straps . . . . . .46-47<br />

LSTI Strap Ties . . . . . . . . . . . . . . .77-78<br />

LTS Tension Ties . . . . . . . . . . . . . . . .45<br />

LTTI31 Tension Tie . . . . . . . . . . . . . .45<br />

LTW Twist Straps . . . . . . . . . . . . .81-82<br />

LUGT Girder Tiedowns . . . . . . . . . .154<br />

MB16 Bridging . . . . . . . . . . . . . . . . .184<br />

MBG Bridging . . . . . . . . . . . . . . . . .184<br />

MGU Girder <strong>Hangers</strong> . . . . . . . . . . . 145<br />

ML Angles . . . . . . . . . . . . . . . . . . . . 201<br />

*<br />

* *<br />

MP Framing Angles . . . . . . . . . . .69-70<br />

MP34 Framing Angle . . . . . . . . . .66-67<br />

MPA1 Framing Angles . . . . . . . . .66-67<br />

* New Products<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

4<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


<strong>USP</strong> Index<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

*<br />

*<br />

*<br />

*<br />

*<br />

MP_F Multi-Lateral Plate Ties . . .66-67<br />

MPH Masonry <strong>Hangers</strong> . .108, 126-141<br />

MRT7 Power Nail <strong>Hangers</strong> . . . . . . .205<br />

MSH Strap <strong>Hangers</strong> . . . . . . . . .168-169<br />

MSHL/R Skewed Truss <strong>Hangers</strong> . . .170<br />

MSSH Skewed Hanger . . . . . . .170-171<br />

MSTA Strap Ties . . . . . . . . . . . . . .77-78<br />

MSTAM Masonry Strap Tie . . . . . . . .84<br />

MSTC Strap Ties . . . . . . . . . . . . .77-79<br />

MSTCB Pre-Bent Strap . . . . . . . . . . .80<br />

MSTCM Masonry Strap Tie . . . . . . . .84<br />

MTHF Power Nail <strong>Hangers</strong> . . . . . . .205<br />

MTW Twist Straps . . . . . . . . . . . . .81-82<br />

MUGT15 Girder Tiedown . . . . . . . . .155<br />

MUS Slant Nail Joist <strong>Hangers</strong> . . . . . . . .<br />

. . . . . . . . . . . . . . . . . . . . . . .89, 91, 167<br />

N Bridging . . . . . . . . . . . . . . . . . . . .183<br />

NA Nails . . . . . . . . . . . . . . . . . . . .14-15<br />

NOP Moisture Barrier Plates . . . . . .152<br />

NP Nail Plates . . . . . . . . . . . . . . . . .198<br />

NSR Nail Stake . . . . . . . . . . . . . . . . .29<br />

O Bridging . . . . . . . . . . . . . . . . . . . .183<br />

Ornamental series . . . . . . . . . . . . . .74<br />

PA Post Anchors . . . . . . . . . . . . . . . .52<br />

PA Purlin Anchors . . . . . . . . . . . . . . .50<br />

PA(E) Post Anchors . . . . . . . . . . . . . .52<br />

PAHD Foundation Straps . . . . . . .48-49<br />

PAI Purlin Anchors . . . . . . . . . . . . . . .50<br />

PAU Post Anchors . . . . . . . . . . . . . . .52<br />

PB Post Caps . . . . . . . . . . . . . . . . . .58<br />

PBC Post Beam Corner . . . . . . . . . .59<br />

PBES Post Caps . . . . . . . . . . . . . . . .58<br />

PBS Post Caps . . . . . . . . . . . . . . . . .58<br />

PCM Post Caps . . . . . . . . . . . . . . . . .57<br />

PCP Plastic Post Caps . . . . . . . . . .204<br />

PHD Predeflected Holdowns . . . . . . .41<br />

PHDA Predeflected Holdowns . . . . . .41<br />

PHM Top Flange <strong>Hangers</strong> . . . . . . . . . . .<br />

. . . . . . . . . . . . . . . . .126-131, 133-141<br />

PHXU Top Flange <strong>Hangers</strong> . . . . . . . . . .<br />

. . . . . . . . . .126-129, 132-136, 138-142<br />

PL4 Protection Plate . . . . . . . . . . . .186<br />

Power- Stud HD5 . . . . . . . . . . . . . .26<br />

PRT Pipe Rail Ties . . . . . . . . . . . . .191<br />

PWFS24 Wood Foundation Strap . . .83<br />

RBC Roof Boundary Clip . . . . . . . . . .68<br />

RC Plywood Clips . . . . . . . . . . . . . .197<br />

RCD Rod Chair . . . . . . . . . . . . . . . . .28<br />

RCT Rod Chair . . . . . . . . . . . . . . . . .28<br />

RFUS Uplift Girder Tie . . . . . . . . . . .153<br />

RKS200 Kwik Strip Ties . . . . . . . . . . .30<br />

*<br />

*<br />

*<br />

*<br />

RP6 Retro Plate . . . . . . . . . . . . . . . . .29<br />

RR Ridge Rafter . . . . . . . . . . . . . . .199<br />

RS Coiled Strapping . . . . . . . . . . . . .76<br />

RSCH Post Anchor . . . . . . . . . . . . .55<br />

RSPT Stud Plate Ties . . . . . . . . . . . .71<br />

RT16M Hurricane Retrofit Connector . .<br />

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .159<br />

RT Hurricane/Seismic Anchors .160-162<br />

RUSC Strap Connector . . . . . . . . . .153<br />

RWB Wall Bracing . . . . . . . . . . . . . .187<br />

SAL Steel Angle Lintels . . . . . . . . . . .27<br />

SB Shelf Brackets . . . . . . . . . . . . . .203<br />

SBP Bearing Plates . . . . . . . . . . . . .178<br />

SCA Stair Angles . . . . . . . . . . . . . . .195<br />

SCH Safety Cap . . . . . . . . . . . . . . . . 28<br />

SCV Safety Cap . . . . . . . . . . . . . . . . .28<br />

SDJT14 Deck Tie . . . . . . . . . . . . . . .193<br />

SDPT Deck Ties . . . . . . . . . . . . . . .193<br />

SF Step Flashing . . . . . . . . . . . . . . .196<br />

SFA Foundation Anchors . . . . . . . . . .33<br />

SFC6 Framing Clip . . . . . . . . . . . . . .75<br />

SFJA Foundation Anchors . . . . . . . .33<br />

SFP Fence Post <strong>Connectors</strong> . . . . . .188<br />

SHA Masonry Uplift <strong>Connectors</strong> . . .157<br />

SKH Skewed 45° <strong>Hangers</strong> . . . .104-105<br />

SKHH Skewed 45° <strong>Hangers</strong> . .104-105<br />

SMP Fence Post <strong>Connectors</strong> . . . . .188<br />

SMRF Hardy Frame Special Moment<br />

Frame . . . . . . . . . . . . . . . . . . . . . .207<br />

SNP3 Skewed Nail Plate . . . . . . . . .171<br />

Specialty Options . . . . . . . . . .210-213<br />

SPT Stud Plate Ties . . . . . . . . . . . . . .71<br />

SPTH Stud Plate Ties . . . . . . . . . . . .71<br />

ST Foundation Anchors . . . . . . . . . . .35<br />

ST Standard Joist <strong>Hangers</strong> . . . . .88, 91<br />

ST Strap Ties . . . . . . . . . . . . . . . .77-78<br />

Stabilizer . . . . . . . . . . . . . . . . . . . .180<br />

STAD Foundation Straps . . . . . . .46-47<br />

STB Anchor Bolts . . . . . . . . . . . . .31-32<br />

STBL Anchor Bolts . . . . . . . . . . . .31-32<br />

STC Scissor Truss Clips . . . . . . . . .177<br />

STS Stud Shoes . . . . . . . . . . . . . . .189<br />

SUH Joist <strong>Hangers</strong> . . . . . . . . .88, 91-96<br />

SW Top Flange <strong>Hangers</strong> . . . . . .98-100<br />

SWH Top Flange <strong>Hangers</strong> . . . . .98-101<br />

T Straps . . . . . . . . . . . . . . . . . . . . . . .74<br />

TA Foundation Straps . . . . . . . . . . . .49<br />

T2JP Type 2 Jack Posts . . . . . . . .38-39<br />

T2CC Type 2 Column Caps . . . . . . . .39<br />

T2TP79 Type 2 Top Plate . . . . . . . . .39<br />

TD Holdowns . . . . . . . . . . . . . . . .42-43<br />

*<br />

*<br />

*<br />

*<br />

*<br />

*<br />

*<br />

*<br />

TDL Concrete Angles . . . . . . . . . . . .46<br />

TDX Holdowns . . . . . . . . . . . . . . .42-43<br />

TFI Top Mount <strong>Hangers</strong> . . . . . . . . . . . . .<br />

. . . . . . . . . .124-125, 130-132, 135-136<br />

TFL Top Mount <strong>Hangers</strong> . . . . . . . . . . . .<br />

. . . . . . . . . . . . . . . . .124-125, 129-131<br />

TH Straps . . . . . . . . . . . . . . . . . . . . . .74<br />

THD Face Mount Truss <strong>Hangers</strong> . . . . . .<br />

. . . . . . . . . . . . . . . . . . . . 120, 123, 165<br />

THDH Heavy Duty Truss Hanger . . . . .<br />

. . . . . . . . . . . . . . . . 120, 123, 166-167<br />

THDS Truss <strong>Hangers</strong> . . . . . . . . . . . .166<br />

THF Face Mount <strong>Hangers</strong> 118, 121-122<br />

THO Top Mount <strong>Hangers</strong> . . . . . . . . . . . .<br />

. . . . . . . . . 124-125, 128-135, 137-138<br />

THR Threaded Rod . . . . . . . . . . . . . .29<br />

TMP Rafter-To-Plate <strong>Connectors</strong> . . .143<br />

TMPH Rafter-To-Plate <strong>Connectors</strong> .143<br />

TPP Mending Plates . . . . . . . . . . . .198<br />

TR Roof Truss Ties . . . . . . . . . . . . .179<br />

TS Truss Spacer . . . . . . . . . . . . . . .181<br />

TSX Truss Spacers . . . . . . . . . . . . .181<br />

TT Products . . . . . . . . . . . . . . .199-200<br />

TUS Undersaddle <strong>Hangers</strong> . . . . . . .111<br />

TW Tie Wire . . . . . . . . . . . . . . . . . . . .27<br />

TWTT Tie Wire Tying Tool . . . . . . . . .27<br />

UCB Undercut Drill Bit . . . . . . . . . . . .23<br />

UMH Universal Masonry <strong>Hangers</strong> . .109<br />

UPHD Holdowns . . . . . . . . . . . . . . . .44<br />

WAS Wet Post Anchors . . . . . . . . . . .53<br />

WB Wall Bracing . . . . . . . . . . . . . . .187<br />

WBC Wall Bracing . . . . . . . . . . . . . .187<br />

WBT Wall Bracing . . . . . . . . . . . . . .187<br />

WE Wet Anchors . . . . . . . . . . . . . . . .53<br />

Wedge-Bolt+ . . . . . . . . . . . . . . . . . .26<br />

Welded Top Flange Products . . . .213<br />

WG Concrete Form Wedge . . . . . . . .30<br />

WM Welded Wire Mesh . . . . . . . . . . .27<br />

WS Wood Screws . . . . . . . . . . . . . . . 16<br />

WS Wood Screw Applications . . .17-19<br />

WT Wall Ties . . . . . . . . . . . . . . . . . .201<br />

Z4 Continuity Tie . . . . . . . . . . . . . .209<br />

Z4 Tension Tie . . . . . . . . . . . . . . . .209<br />

Z4 Continuous Rod Tie-Down Systems<br />

. . . . . . . . . . . . . . . . . . . . . . . . . . . 208<br />

ZC Blocking Supports . . . . . . . . . . .179<br />

New Products<br />

Reference Number Index on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 5<br />

<strong>USP</strong>2240-131


1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

6<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Reference Number Index<br />

About the Reference Numbers<br />

Reference numbers shown throughout the<br />

charts in this catalogue are part numbers<br />

which may be more familiar to customers in<br />

various regions of Canada. These are<br />

included for the convenience of our new<br />

customers who have recently switched from a<br />

competitor’s product line to <strong>USP</strong>.<br />

The reference numbers in this catalogue<br />

are for general application comparison<br />

only and should not be used as a<br />

substitution tool. The user is responsible<br />

to compare specific load values, fastener<br />

schedules, material specifications, and<br />

other factors to determine suitability of<br />

use for any particular product.<br />

A Angle . . . . . . . . . . . . . . . . . . . . .46, 70, 73<br />

A34, A35 Anchor . . . . . . . . . . . . . . . . . . . .67<br />

ABA Post Base . . . . . . . . . . . . . . . . . . . . .52<br />

ABU Post Base . . . . . . . . . . . . . . . . . . . . .52<br />

AC Post Cap . . . . . . . . . . . . . . . . . . . . . . .58<br />

ACE Post Cap . . . . . . . . . . . . . . . . . . . . . .58<br />

B/BA Hanger . . . . . . . . . . . . . . . . . . . . . . . .<br />

. . . . . . .99-101, 129, 133-135,138, 140-142<br />

BC Base . . . . . . . . . . . . . . . . . . . . . . . . . .55<br />

BC Cap . . . . . . . . . . . . . . . . . . . . . . . . . . .58<br />

BCS Cap . . . . . . . . . . . . . . . . . . . . . . . . . .58<br />

BP Bearing Plate . . . . . . . . . . . . . . . . . . . .20<br />

BT Brick Tie . . . . . . . . . . . . . . . . . . . . . . .201<br />

CB Column Base . . . . . . . . . . . . . . . . . . . .56<br />

CBQ Column Base . . . . . . . . . . . . . . . . . .56<br />

CBSQ Column Base . . . . . . . . . . . . . . . . .55<br />

CCQ Column Cap . . . . . . . . . . . . . . . .60-61<br />

CMST Strap . . . . . . . . . . . . . . . . . . . . . . . .76<br />

CMSTC Coiled Strap . . . . . . . . . . . . . . . . .76<br />

CPS Composite Standoff . . . . . . . . . . . . . .59<br />

CS Strap . . . . . . . . . . . . . . . . . . . . . . . . . .76<br />

DBTZ Deck Tie . . . . . . . . . . . . . . . . . . . .185<br />

DJT Deck Tie . . . . . . . . . . . . . . . . . . . . . .193<br />

DPPC Decorative Post Cover . . . . . . . . .204<br />

DPT Deck Tie . . . . . . . . . . . . . . . . . . . . .193<br />

DS Drywall Stop . . . . . . . . . . . . . . . . . . .197<br />

DSC Drag Strut Connector . . . . . . . . . . .181<br />

DSP Double Stud Plate . . . . . . . . . . . . . . .71<br />

DTC Roof Truss Clip . . . . . . . . . . . . . . . .179<br />

DTT2Z Deck Tension Tie . . . . . . . . . . . . .192<br />

ECCQ Column Cap . . . . . . . . . . . . . . .61-62<br />

EG Hanger . . . . . . . . . . . . . . . . . . . . . . . .147<br />

EPB Post Base . . . . . . . . . . . . . . . . . . . . .54<br />

EPC Post Cap . . . . . . . . . . . . . . . . . . . . . .57<br />

FB Fence Bracket . . . . . . . . . . . . . . . . . .190<br />

FC Framing Clip . . . . . . . . . . . . . . . . . . . .75<br />

FJA Anchor . . . . . . . . . . . . . . . . . . . . . . . .33<br />

FPBB44 E-Z Base . . . . . . . . . . . . . . . . . .189<br />

FPBM44E E-Z Mender . . . . . . . . . . . . . .188<br />

FPBS44 E-Z Spike . . . . . . . . . . . . . . . . .188<br />

FGTR Girder Tiedown . . . . . . . . . . . . . . .153<br />

FSC Strap . . . . . . . . . . . . . . . . . . . . . . . .192<br />

GA Angle . . . . . . . . . . . . . . . . . . . . . . . . . .70<br />

GB Hanger . . . . . . . . . . . . . . . . . . . . . . .148<br />

GBC Gable Bracing . . . . . . . . . . . . . . . . .162<br />

GLB Beam Seat . . . . . . . . . . . . . . . . . . . .36<br />

GLBT Beam Seat . . . . . . . . . . . . . . . . . . .36<br />

GLS Hanger . . . . . . . . . . . . . . . . . . . . . .150<br />

GLT Hanger . . . . . . . . . . . . . . . . . . . . . . .149<br />

GLTV Hanger . .132, 134-135, 138-142, 149<br />

H Hurricane Ties . . . . . . . . . . . . . . . .82, 162<br />

HB Hanger . . . . . . . . . . . .133-136, 138-142<br />

HCP Hip Corner Plate . . . . . . . . . . . . . . .162<br />

HD Holdown . . . . . . . . . . . . . . . . . . . . . . .43<br />

HDB Holdown . . . . . . . . . . . . . . . . . . . . . .43<br />

HDU Holdown . . . . . . . . . . . . . . . . . . .41, 44<br />

HDQ Holdown . . . . . . . . . . . . . . . . . . . . . .44<br />

HGA Gusset Angle . . . . . . . . . . . . . . . . .158<br />

HGAM Gusset Angle . . . . . . . . . . . . . . . .158<br />

HGB Hanger . . . . . . . . . . . . . . . . . . . . . .148<br />

HGLB Beam Seat . . . . . . . . . . . . . . . . . . .36<br />

HGLS Hanger . . . . . . . . . . . . . . . . . . . . .150<br />

HGLT Hanger . . . . . . . . . . . . . . . . . . . . .149<br />

HGLTV Hanger . . . . .134-135, 138-142, 149<br />

HGT Girder Tiedown . . . . . . . . . . . . . . . .156<br />

HGU Girder Hanger . . . . . . . . . . . . . . . . .145<br />

HGUS Hanger . . . . . . . . . . . . . . . . .123, 167<br />

HH Hanger . . . . . . . . . . . . . . . . . . . . . . . . .75<br />

HHB Hanger . . . . . . . . . . . . . . .100-101, 148<br />

HHDQ Holdown . . . . . . . . . . . . . . . . . . . . .44<br />

HHUS Hanger . . . . . . . . . . . . . . . . . 123, 165<br />

HIT Hanger . . . . . . . . . . . .130-132, 135-136<br />

HL Angle . . . . . . . . . . . . . . . . . . . . . . . . . .73<br />

HL Strap Tie . . . . . . . . . . . . . . . . . . . . . . .74<br />

HM Hurricane Tie . . . . . . . . . . . . . . . . . .159<br />

HRS Strap Tie . . . . . . . . . . . . . . . . . . . . . .79<br />

HS Hurricane Tie . . . . . . . . . . . . . . . . . . .162<br />

HSUR/HSUL Hanger . . . . . . . . . . . . . . . .105<br />

HT Strap Tie . . . . . . . . . . . . . . . . . . . . . . .74<br />

HTC Heavy Truss Clip . . . . . . . . . . . . . . .179<br />

HTP Strap Tie . . . . . . . . . . . . . . . . . . . . . .78<br />

HTS Twist Strap . . . . . . . . . . . . . . . . . . . . .82<br />

HTSM Twist Strap . . . . . . . . . . . . . . . . . . .85<br />

HTT Tension Tie . . . . . . . . . . . . . . . . . . . .45<br />

HTU Hanger . . . . . . . . . . . . . . . . . . . . . .165<br />

HU Hanger . . . . . . . . . .91-96, 121-123, 167<br />

HUC Hanger . . . . . . . . . . . . . . . . . . . . .91-96<br />

HUCQ Hanger . . . . . . . . . . . . . . .92-96, 123<br />

HUS Hanger . . . . . . . . . . . . .91-95, 123, 167<br />

HUSTF Hanger . . . . . . . . . . . . . . . . . .99-100<br />

HUTF Hanger . . . . . . . . . . . . . . . . . . .99-101<br />

HW Hanger . . . . . . . . . . . . . . . . . . . .100-101<br />

HWI Hanger . . . . . . . . . . .133-136, 141-142<br />

HWU Hanger . . . . . . . . . . .132-135, 138-140<br />

ITS Hanger . . . . . . . . . . . . . . . . . . . .128-131<br />

IUS Hanger . . . . . . . . . . . . . . . . . . . .121-122<br />

IUT Hanger . . . . . . . . . . . . . . . . . . . .121-122<br />

JB Hanger . . . . . . . . . . . . . . . . . . . . . . . . .99<br />

L Angle . . . . . . . . . . . . . . . . . . . . . . . . . . .70<br />

L Strap Tie . . . . . . . . . . . . . . . . . . . . . . . . .74<br />

LB Hanger . . . . . . . . . . . . . . . . . . . . . . . . .99<br />

LBP Bearing Plate . . . . . . . . . . . . . . . . . . .20<br />

LBV Hanger . . . . . . . . . . . . . . . . . . .128-138<br />

LCB Column Base . . . . . . . . . . . . . . . . . .56<br />

LEG Hanger . . . . . . . . . . . . . . . . . . . . . .147<br />

LF Hanger . . . . . . . . . . . . . . . . . . . .121-122<br />

LGT Girder Tiedown . . . . . . . . . . . . . . . .154<br />

LGU Girder Hanger . . . . . . . . . . . . . . . . .145<br />

LJS26DS Hanger . . . . . . . . . . . . . . . . . .167<br />

LPC Post Cap . . . . . . . . . . . . . . . . . . . . . .58<br />

LS Angle . . . . . . . . . . . . . . . . . . . . . . . . . .70<br />

LSCZ Stringer Connector . . . . . . . . . . . .194<br />

LSSU Hanger . . . . . . . . . . . . . . . . .103, 144<br />

LSTA Strap Tie . . . . . . . . . . . . . . . . . . . . .78<br />

LSTHD Holdown . . . . . . . . . . . . . . . . . . . .47<br />

LSTI Strap Tie . . . . . . . . . . . . . . . . . . . . . .78<br />

LSU Hanger . . . . . . . . . . . . . . . . . .103, 144<br />

LT Hanger . . . . . . . . . . . . . . . . . . . .128-135<br />

LTA Truss Anchor . . . . . . . . . . . . . . . . . .152<br />

LTB Bridging . . . . . . . . . . . . . . . . . . . . . .183<br />

LTHJA Hanger . . . . . . . . . . . . . . . . . . . . .173<br />

LTHJL/R Hanger . . . . . . . . . . . . . . . . . . .173<br />

LTP Framing Anchor . . . . . . . . . . . . . . . . .67<br />

LTS Twist Strap . . . . . . . . . . . . . . . . . . . .82<br />

LTT/LTTI Tension Tie . . . . . . . . . . . . . . . . .45<br />

LU Hanger . . . . . . . . . . . . . . . . . . . . . .91, 96<br />

LUCZ Hanger . . . . . . . . . . . . . . . . . . . . . .91<br />

LUS Hanger . . . . . . . . . . . . . . . . . . . . .91-95<br />

MAB Mudsill Anchor . . . . . . . . . . . . . . . . .35<br />

MAS Mudsill Anchor . . . . . . . . . . . . . . . . .34<br />

MBHU Hanger . . . . . . . . . . . . . . . . . . . . .109<br />

MEG Hanger . . . . . . . . . . . . . . . . . . . . . .147<br />

MGT Girder Tiedown . . . . . . . . . . . . . . . .155<br />

MGU Girder Hanger . . . . . . . . . . . . . . . .145<br />

MIT Hanger . . . . . . . . . . . . . . . . . . .128-138<br />

MIU Hanger . . . . . . . . . . . . . . . . . . .121-123<br />

ML Angles . . . . . . . . . . . . . . . . . . . . . . . .201<br />

MMH8 Hurricane Tie . . . . . . . . . . . . . . . .205<br />

MMLU Hanger . . . . . . . . . . . . . . . . . . . . .205<br />

MP Mending Plate . . . . . . . . . . . . . . . . . .198<br />

MST Strap Tie . . . . . . . . . . . . . . . . . . . . . .79<br />

MSTA Strap Tie . . . . . . . . . . . . . . . . . . . . .78<br />

MSTAM Strap Tie . . . . . . . . . . . . . . . . . . .84<br />

MSTC Strap Tie . . . . . . . . . . . . . . . . . .78-79<br />

MSTCB Strap Tie . . . . . . . . . . . . . . . . . . .80<br />

MSTCM Strap Tie . . . . . . . . . . . . . . . . . . .84<br />

MSTI Strap Tie . . . . . . . . . . . . . . . . . . . . . .79<br />

MTS Twist Strap . . . . . . . . . . . . . . . . . . . .82<br />

MTSM Twist Strap . . . . . . . . . . . . . . . . . . .85<br />

MUS Hanger . . . . . . . . . . . . . . . . . . .91, 167<br />

Nails . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14<br />

NCA Nailless Bridging . . . . . . . . . . . . . . .184<br />

NS Nail Stopper . . . . . . . . . . . . . . . . . . . .186<br />

OHA Hanger . . . . . . . . . . . . . . . . . . . . . . .74<br />

OL/OT/OHL/OHT <strong>Hangers</strong> . . . . . . . . . . . .74<br />

OS/OHS <strong>Hangers</strong> . . . . . . . . . . . . . . . . . . .74<br />

PA Purlin Anchor . . . . . . . . . . . . . . . . .49-50<br />

PAI Purlin Anchor . . . . . . . . . . . . . . . . . . .50<br />

PB Post Base . . . . . . . . . . . . . . . . . . . . . .53<br />

PBS Post Base . . . . . . . . . . . . . . . . . . . . .53<br />

PC Post Cap . . . . . . . . . . . . . . . . . . . . . . .57<br />

PF Hanger . . . . . . . . . . . . . . . . . . . .110, 112<br />

PGT Pipe Grip Tie . . . . . . . . . . . . . . . . . .191<br />

PGTIC Pipe Grip Tie . . . . . . . . . . . . . . . .191<br />

PSPN Protective Plate . . . . . . . . . . . . . .186<br />

PSCA/PSCL Sheathing Clip . . . . . . . . . .197<br />

PWF24 Strap Tie . . . . . . . . . . . . . . . . . . . .83<br />

RBC Roof Boundary Clip . . . . . . . . . . . . .68<br />

RCPS Post Base . . . . . . . . . . . . . . . . . . . .54<br />

RCWB Wall Bracing . . . . . . . . . . . . . . . .187<br />

RFB Retro Fit Bolt . . . . . . . . . . . . . . . . . . .29<br />

RP Retro Plate . . . . . . . . . . . . . . . . . . . . .29<br />

RPS Strap Tie . . . . . . . . . . . . . . . . . . . . . .80<br />

RR Connector . . . . . . . . . . . . . . . . . . . . .199<br />

RSP Stud Plate Tie . . . . . . . . . . . . . . . . . .71<br />

RTA/RTB/RTC/RTF/RTR/RTU Rigid Tie .200<br />

S/A23 Angle . . . . . . . . . . . . . . . . . . . . . . . .70<br />

SD Structural Connector Screw . . . . . . . . .20<br />

SDS Screw . . . . . . . . . . . . . . . . . . . . . .16-19<br />

S/H Hurricane Ties . . . . . . . . . . . . . . . . .162<br />

S/HTC Clip . . . . . . . . . . . . . . . . . . . . . . . .179<br />

S/LS Angle . . . . . . . . . . . . . . . . . . . . . . . . .70<br />

S/MST Strap Tie . . . . . . . . . . . . . . . . . . . .79<br />

SP Stud Plate Tie . . . . . . . . . . . . . . . . . . .71<br />

Specangle . . . . . . . . . . . . . . . . . . . . . . . . .73<br />

SPH Stud Plate Tie . . . . . . . . . . . . . . . . . .71<br />

S/PSPN Nail Stopper . . . . . . . . . . . . . . . .186<br />

SS Stud Shoe . . . . . . . . . . . . . . . . . . . . .189<br />

SSP Single Stud Plate . . . . . . . . . . . . . . . .71<br />

SSTB Anchor Bolt . . . . . . . . . . . . . . . . . . .32<br />

ST Strap Tie . . . . . . . . . . . . . . . . . . . . .78-79<br />

STC Roof Truss Clip . . . . . . . . . . . . . . . .179<br />

STHD Holdown . . . . . . . . . . . . . . . . . . . . .47<br />

SUR/SUL Hanger . . . . . . . . . . . . . . .104-105<br />

T Strap Tie . . . . . . . . . . . . . . . . . . . . . . . . .74<br />

TA Staircase Angle . . . . . . . . . . . . . . . . .195<br />

TB Tension Bridging . . . . . . . . . . . . . . . .183<br />

TBE Truss Enhancer . . . . . . . . . . . . . . . .178<br />

TC Truss Connector . . . . . . . . . . . . . . . .177<br />

THA/THAC Hanger . . . . . . . . . . . . . . . . .169<br />

THAI Hanger . . . . . . . . . . . . . . . . . . . . . .169<br />

THGB Hanger . . . . . . . . . . . . . . . . . . . . .174<br />

THGBH Hanger . . . . . . . . . . . . . . . . . . . .174<br />

THGQ/THGQH Hanger . . . . . . . . . . . . . .176<br />

THJA Hanger . . . . . . . . . . . . . . . . . . . . .173<br />

THJM Hanger . . . . . . . . . . . . . . . . . . . . .172<br />

THJU Hanger . . . . . . . . . . . . . . . . . . . . .173<br />

TJC37 Truss Connector . . . . . . . . . . . . .171<br />

TP Tie Plate . . . . . . . . . . . . . . . . . . . . . . .198<br />

TS Twist Strap . . . . . . . . . . . . . . . . . . . . . .82<br />

TSB Truss Spacer . . . . . . . . . . . . . . . . . .180<br />

TSF Truss Spacer . . . . . . . . . . . . . . . . . .181<br />

TSP Stud Plate Tie . . . . . . . . . . . . . .82, 162<br />

TSS Truss Seat . . . . . . . . . . . . . . . . . . . .152<br />

TWB Wall Bracing . . . . . . . . . . . . . . . . . .187<br />

U Hanger . . . . . . . . . . . . . . . .91-96, 121,123<br />

VPA Connector . . . . . . . . . . . . . . . . . . . .143<br />

W Hanger . . . . . . . . . . . . . . . . . . . . . .99-100<br />

W Wedge . . . . . . . . . . . . . . . . . . . . . . . . . .30<br />

WB/WBC Wall Bracing . . . . . . . . . . . . . .187<br />

WM Hanger .108, 128-130, 132-134, 137-139<br />

WMI Hanger . . . . . . . . . . .134-136, 140-141<br />

WNP Hanger . . . . . . . . . . . . . . . . . . .99-101<br />

WP Hanger . . . .128-130, 132-133, 137-138<br />

WPI Hanger . . . . . . .131-136, 138, 140-141<br />

WPU Hanger . . . . . . . . . . .128-129, 133-136<br />

WT Wedge Form Tie . . . . . . . . . . . . . . . . .30<br />

Z Clip . . . . . . . . . . . . . . . . . . . . . . . . . . . .179


Corrosion Information<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

Triple Zinc G-185<br />

<strong>Connectors</strong>, including anchors and fasteners,<br />

installed in corrosive environments or exposed to<br />

corrosive materials, or chemicals, can be damaged<br />

possibly resulting in the reduction of load capacity.<br />

The selection of the proper connector coating can<br />

be a complicated task. Environments can vary<br />

greatly regionally and are also influenced by<br />

variables such as fertilizer, animal waste, and wet<br />

cycle durations. If an electrolyte is present, such as<br />

water, a metal will form an electric circuit with a<br />

dissimilar metal and galvanic corrosion can take<br />

place. Zinc is the metal used in the hot-dip<br />

galvanizing process due to its ability to sacrifice<br />

itself while protecting the base steel underneath.<br />

When the zinc and copper are in electrical contact<br />

with each other the copper will have a tendency to<br />

extract electrons from the highly reactive zinc at a<br />

greater rate, therefore corrosion will take place at a<br />

greater rate. That being the case it is impossible to<br />

prescribe a reasonable uniform solution which will<br />

serve all environments adequately.<br />

Chemical producers in the treated wood industry<br />

agreed to discontinue the use of Chromated<br />

Copper Arsenate (CCA) for most residential<br />

applications at the end of 2003. In place of CCA,<br />

treated wood suppliers use copper based<br />

alternative treatment chemicals. Testing conducted<br />

by <strong>USP</strong> and others in the industry have concluded<br />

the ACQ and Copper Azole wood treatments are<br />

more corrosive to metals than traditionally used<br />

CCA treatments are.<br />

<strong>USP</strong> Structural <strong>Connectors</strong> currently offers five<br />

different corrosion resistant finishes to cover a<br />

range of corrosion performance:<br />

G90 Galvanizing – galvanizing provides a<br />

prefabrication coating of 0.90 ounces of zinc per<br />

square foot of surface area measured in<br />

accordance with ASTM A 653.<br />

Triple Zinc (TZ) –<br />

galvanizing provides a prefabrication coating of<br />

1.85 (G-185) ounces of zinc per square foot of<br />

surface area measured in accordance with ASTM<br />

A 653.<br />

Required Fastener: Hot-dip galvanized fasteners<br />

Hot-Dip Galvanized (HDG) – coating provides an<br />

after-fabrication hot-dipped zinc coating. The<br />

coating thickness is dependent on the connector<br />

material, but generally ranges from 1.1 to 2.3<br />

ounces of zinc per square foot of surface. Hot-dip<br />

products meet requirements set forth in ASTM A<br />

123.<br />

Require Fastener: Hot-dip galvanized fasteners<br />

Gold Coat (GC) –<br />

Gold Coat is a proprietary multi-layer protection<br />

system. It is comprised of an organic top coat<br />

barrier layer and a zinc layer placed over a steel<br />

substrate.<br />

Required Fastener: Gold Coat fasteners<br />

Hot-Dip Galvanized<br />

Recently some wood preservative manufacturers<br />

have introduced new wood preservative<br />

formulations. These formulations include new<br />

micronized copper products as well as carbon<br />

based PTI wood preservatives.<br />

Structural <strong>Connectors</strong> Coating Recommendations<br />

Stainless Steel (SS) – is the best option for<br />

corrosion protection. Quality stainless steel (316SS<br />

grade steel) is used to fabricate connectors.<br />

Although costs are higher, some applications may<br />

need the virtual corrosion proof quality of stainless<br />

steel.<br />

Required Fastener: Stainless Steel fasteners<br />

AWPA Use Service Use Example Preservatives and Minimum Coating<br />

Category Conditions Environment Applications Retentions 6,7 Requirements 1,2,3,4<br />

UC1 Interior construction, Continuously protected from General framing,<br />

Above ground, weather or other sources of interior construction Untreated G90<br />

Dry<br />

moisture<br />

UC2 Interior construction, Protected from weather, but may be Sill plates SBX-DOT, Organic G90<br />

Above ground, subject to sources of moisture ACQ-D (0.25), CA-B (0.10), Triple Zinc (G-185) 8,9<br />

Damp CA-C (0.06), MCQ (0.25),<br />

µCA-C (0.05)<br />

UC3A Exterior construction, Exposed to all weather cycles, not Exposed exterior beams ACQ-D (0.25), MCQ (0.25), Triple Zinc (G-185) or<br />

Above ground, exposed to prolonged wetting or columns in an open, CA-B (0.10), CA-C (0.06), <strong>USP</strong> Gold Coat<br />

Rapid water runoff covered structure µCA-C (0.05), Organic<br />

UC3B Exterior construction, Exposed to all weather cycles, Deck beams and joists ACQ-D (0.25), MCQ (0.25), Triple Zinc (G-185) or<br />

Above ground, including prolonged wetting CA-B (0.10), CA-C (0.06), <strong>USP</strong> Gold Coat<br />

Poor water runoff<br />

µCA-C (0.05), Organic<br />

Gold Coat<br />

UC4A Exterior construction, Ground contact or fresh water Deck posts ACQ-D (0.40), MCQ (0.40), Triple Zinc (G-185) or<br />

Ground contact, exposed to all weather cycles CA-B (0.21), CA-C (0.15), <strong>USP</strong> Gold Coat 5<br />

General use µCA-C (0.14)<br />

UC4B Exterior construction, Ground contact, fresh or salt water Permanent wood ACQ-D (0.60), MCQ (0.60), Stainless Steel<br />

Ground contact, exposed to all weather cycles foundations, critical CA-B (0.31), CA-C (0.25),<br />

Critical structural structural members µCA-C (0.23)<br />

Notes:<br />

1. G90 and G185 refer to galvanization requirements for ASTM A653 material.<br />

2. <strong>Connectors</strong> galvanized to ASTM A123 may be used in place of either G90 or G185 coatings.<br />

3. Other coating may be suitable for a given environment if the conditions are known and predictable.<br />

For Gold Coat connectors use Gold Coat fasteners, and for<br />

4. For G90 or G185 connectors use fasteners galvanized per ASTM A153. For Gold Coat connectors use Gold Coat fasteners, and for stainless steel<br />

stainless steel connectors use stainless steel fasteners.<br />

connectors use stainless steel fasteners.<br />

5<br />

5. If the environment has the potential to contain elements which may make it more corrosive, the use of stainless steel is recommended.<br />

6. MCQ is a micronized copper treatment such as Micro Pro by Osmose. µCA-C is a dispersed copper treatment manufactured by Arch Treatment Technologies.<br />

Organic preservatives include L3 from Arch Treatment Technologies and EcoLife II from Viance, LLC.<br />

7. For wood treatments not shown contact <strong>USP</strong> or the wood preservative manufacturer for recommended coatings.<br />

8. Testing G90 connectors by <strong>USP</strong> with has MCQ found or µCA-C that in treated interior wood applications is appropriate. where the treated wood will remain relatively dry during its service life the use of G90 connectors with<br />

MCQ or µCA-C treated wood is appropriate.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 7<br />

<strong>USP</strong>2240-131


Corrosion Information<br />

The structural connectors coating recommendations chart on<br />

page 7 has been developed by reviewing both field service<br />

performance and accelerated corrosion testing results. While<br />

accelerated corrosion testing is a valuable tool to help predict<br />

relative performance, both the particular testing method used<br />

by the industry and the different wood treatment products<br />

tested are relatively new and there is little actual field service<br />

life data to correlate to the test results. In addition, actual<br />

service environments are much more complicated than<br />

accelerated tests. In accelerated tests influencing variables<br />

are typically minimized and manipulated to cause reactions to<br />

occur more quickly. Consequently this may result in reactions<br />

which are not completely representative of actual service<br />

conditions. Because of this it is difficult to assign an expected<br />

service life to a given coating in an environment based on the<br />

results of accelerated testing.<br />

The formulations used by wood preservative manufacturers<br />

are constantly changing and improving. <strong>USP</strong> Structural<br />

<strong>Connectors</strong> continues to test new wood treatments as they<br />

become available and will continue to update its<br />

recommendation as appropriate.<br />

Corrosion Protection Guidelines:<br />

• <strong>USP</strong> recommends stainless steel connectors for the highest<br />

level of corrosion protection. As an economical alternative to<br />

stainless steel our new Gold Coat connectors are specifically<br />

designed for exterior application when in contact with<br />

preservative treated wood.<br />

• Triple Zinc G-185 connectors are available as an economical<br />

alternative for exterior applications which will provide a<br />

minimum level of protection.<br />

• The use of correct fastener with the connector is critical.<br />

Stainless steel connectors require stainless steel fasteners.<br />

For exterior applications, hot-dip galvanized fasteners (HDG)<br />

must be used with both Triple Zinc and Hot-dip galvanized<br />

finishes. Gold Coat connectors require gold coat fasteners.<br />

• <strong>USP</strong>’s zinc dichromate WS Wood Screws are not<br />

recommended for use with preservative or fire-retardant<br />

treated wood. Some wood screws are available in Gold Coat.<br />

• <strong>USP</strong> Structural <strong>Connectors</strong> clearly differentiates<br />

standard G90 connectors from the corrosion resistant<br />

connectors. Gold Coat connectors are distinguishable from<br />

other connectors because of their concealing color. Examples<br />

of our carton labels, bin cards for retail displays, and<br />

individual product labels are found below.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>USP</strong> recommendation<br />

and standards<br />

met with Triple<br />

Zinc coating.<br />

Part number is<br />

referenced with<br />

a TZ at the<br />

end for Triple<br />

Zinc products.<br />

Bin Card<br />

Yellow oval boldly<br />

highlights “for use<br />

with treated wood”<br />

TZ - Triple Zinc logo identifies<br />

products that have G-185<br />

galvanization.<br />

Product Label<br />

Part number is referenced<br />

with a TZ at the end for<br />

Triple Zinc products.<br />

, FL821.42<br />

Triple Zinc G-185 is<br />

referenced above<br />

the bar code.<br />

Part number is<br />

referenced with a TZ<br />

at the end for Triple<br />

Zinc products.<br />

Carton Label<br />

Scan for more<br />

Information!<br />

100 PCS.<br />

Made in:/Hencho en:/Fabriqué au U.S.A<br />

Light green background<br />

colour indicates a corrosion<br />

resistant product.<br />

<strong>USP</strong> recommendation and<br />

standards that are met with<br />

the Triple Zinc coating.<br />

8<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Product Information<br />

U.S. Standard Steel gauge<br />

Equivalents in Nominal Dimensions<br />

Special & Custom <strong>Connectors</strong><br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Approximate Dimensions<br />

Decimals (inches)<br />

Gauge Inches Millimeters Uncoated Steel Galvanized Steel (G90) Triple Zinc (G-185)<br />

3 1/4 6.0 0.238 -- -- -- --<br />

7 3/16 4.5 0.171 0.186 -- --<br />

10 9/64 3.4 0.129 0.138 0.140<br />

11 1/8 3.0 0.114 0.123 0.125<br />

12 7/64 2.7 0.099 0.108 0.110<br />

14 5/64 2.0 0.070 0.078 0.080<br />

16 1/16 1.5 0.055 0.063 0.065<br />

18 3/64 1.2 0.044 0.052 0.054<br />

20 1/32 1.0 0.033 0.040 0.042<br />

22 1/32 0.8 0.029 0.033 0.036<br />

*Actual steel dimensions will vary from nominal dimensions according to industry tolerances.<br />

Maximum Shear Capacity<br />

of Joist or Rafter<br />

The table below indicates the calculated shear capacity of different<br />

dimensional lumber sizes for various wood species.<br />

Factored Shear Resistance 1,2<br />

Lbs<br />

kN<br />

Nom DF<br />

SPF<br />

DF<br />

S-P-F<br />

Dim 100% 4 115% 3 100% 4 115% 3 100% 4 115% 3 100% 4 115% 3<br />

2 x 4 1476 1697 1165 1340 6.57 7.55 5.18 5.96<br />

2 x 6 1910 2197 1508 1734 8.50 9.77 6.71 7.71<br />

2 x 8 2158 2482 1703 1958 9.60 11.04 7.58 8.71<br />

2 x 10 2524 2903 1992 2291 11.23 12.91 8.86 10.19<br />

1) Applies to nominally dimensioned joist as listed in dry service conditions and temperatures less than 38º C.<br />

2) Loads apply to: DF-L: Douglas Fir-Larch (G=0.49), fv=1.9 Mpa; S-P-F: Spruce-Pine-Fir (G=0.42), fv=1.5 Mpa<br />

3) 115% loads are increased for short term loading in accordance with the code. Kd = 1.15.<br />

4) Assumes system factor Kh = 1.00.<br />

<strong>USP</strong> is committed to meeting every need you<br />

have and we understand that stock connectors<br />

will not meet all application or design<br />

requirements. Our Technical Assistance<br />

Representatives will work with you to develop<br />

and fabricate the Special or Custom connector<br />

you need.<br />

What is the difference between a “Special”<br />

and a “Custom” connector<br />

A “Special” is a stock <strong>USP</strong> connector that is<br />

modified within the limits listed in the Specialty<br />

Options chart.<br />

A “Custom” is a connector that does not closely<br />

resemble a stock or special part offered in our<br />

catalog. Also, a “Custom” connector may be a<br />

stock connector that is modified outside of the<br />

limits listed in the Specialty Options charts or is<br />

not listed in the catalog as having a specialty<br />

option available. Product drawings must be<br />

provided by the customer and will be<br />

manufactured by <strong>USP</strong> in accordance to<br />

customer specifications.<br />

A full range of shipping options are available<br />

from regular freight to overnight delivery.<br />

Roof Pitch<br />

If common Rafter<br />

Roof Pitch is . . .<br />

Rise / Run<br />

(inches)<br />

Slope<br />

(degrees)<br />

Then Hip/Valley<br />

Rafter Roof Pitch<br />

becomes . . .<br />

Rise / Run<br />

(inches)<br />

Slope<br />

(degrees)<br />

1/12 5 1/17 3<br />

2/12 10 2/17 7<br />

3/12 14 3/17 10<br />

4/12 18 4/17 13<br />

5/12 23 5/17 16<br />

6/12 27 6/17 19<br />

7/12 30 7/17 22<br />

8/12 34 8/17 25<br />

9/12 37 9/17 28<br />

10/12 40 10/17 30<br />

11/12 42 11/17 33<br />

12/12 45 12/17 35<br />

1) Use this conversion table only for hip/valley rafters that are<br />

skewed 45° right or left. All other skews or dual pitch roofs<br />

will cause the slope to change from that listed above.<br />

Uplift<br />

Slope<br />

Conversion Table<br />

Rise / Run<br />

(inches)<br />

Load Direction Conventions<br />

Slope<br />

(degrees)<br />

0/12 Flat<br />

1/12 5<br />

2/12 10<br />

3/12 14<br />

4/12 18<br />

5/12 23<br />

6/12 27<br />

7/12 30<br />

8/12 34<br />

9/12 37<br />

10/12 40<br />

11/12 42<br />

12/12 45<br />

1 5 /8˝<br />

37°<br />

7˝<br />

Special Order detail<br />

4 1 /16˝<br />

23º<br />

1 5 /8˝<br />

41º<br />

1 5 /8˝<br />

(9)<br />

3 /16˝<br />

Perpendicular<br />

Lateral<br />

F 1<br />

22˝<br />

F 2<br />

F 2 or F 3<br />

Out<br />

F 1<br />

Download<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

Custom Order detail<br />

<strong>USP</strong>2240-131<br />

9


Product Notes<br />

1) This catalogue reflects the most current information<br />

regarding <strong>USP</strong> product line. However, product revisions and<br />

new product additions occur on an ongoing basis. <strong>USP</strong><br />

Structural <strong>Connectors</strong>® reserves the right to change<br />

specifications, designs, and models at any time without<br />

notice and liability for such changes. This catalogue may not<br />

be reproduced in whole or in part without the prior written<br />

approval of <strong>USP</strong> Structural <strong>Connectors</strong>®.<br />

2) This catalogue reflects design changes and design load<br />

adjustments to some <strong>USP</strong> products. The information<br />

presented in this publication replaces all information<br />

published in previous documents, and is valid until<br />

December 31, 2014.<br />

3) This Product Catalogue was designed as a general<br />

reference for the <strong>USP</strong> Product Line. Various specialized<br />

publications have been developed for design professionals,<br />

truss manufacturers, contractors, retail dealers, and building<br />

material wholesalers. Product load values may vary from one<br />

publication to another due to recent product testing, changes<br />

in regulatory criteria, or code evaluation updates. The most<br />

current product information is available on <strong>USP</strong>’s Web Site.<br />

4) The type and quantity of fasteners used to install <strong>USP</strong><br />

products is critical to connector performance. To achieve the<br />

resistance values presented in this catalogue, all specified<br />

fasteners must be used and proper installation procedures<br />

observed. Verify that the dimensions of supporting members<br />

are sufficient to receive specified fasteners. Any product<br />

modifications void the warranty unless prior written<br />

permission of <strong>USP</strong> Structural <strong>Connectors</strong>® is obtained.<br />

ASME SAE Grade 2, or better unless noted otherwise.<br />

13) Anchor Bolts conform to ASTM F 1554.<br />

14) <strong>USP</strong> connectors listed in this catalogue are manufactured<br />

for specific sizes of standard lumber, plated trusses, or<br />

composite lumber. For applications involving unusual<br />

supporting conditions environments, contact <strong>USP</strong>. Wood<br />

shrinkage or expansion, caused by lack of moisture or<br />

excessive moisture, may adversely affect connector<br />

installation. Evaluate potential shrinking or expanding to<br />

ensure proper connector installation and performance.<br />

15) The load values listed in this catalogue are based on<br />

installation to wood with a moisture content of less than 19%,<br />

and used in dry service conditions. Load reductions, in<br />

accordance with the code, shall be taken where wood<br />

moisture content greater than 19% at the time of installation<br />

or where used in wet service conditions.<br />

16) Unless otherwise noted, <strong>USP</strong> products may not be bent<br />

or cut in the field to facilitate installation. Field alterations may<br />

weaken steel and cause connector failure at lower than<br />

published factored resistance.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

5) Some connector models are listed more than once to<br />

indicate installation and/or fastener options.<br />

6) New products or updated product information are<br />

designated in red font.<br />

7) Throughout this catalogue, dimensions are expressed in<br />

inches and loads in pounds unless specifically noted<br />

otherwise.<br />

8) Some <strong>USP</strong> products show both bolt and nail fastening<br />

schedules. In those cases, specific loads for each has been<br />

identified. Bolt and nail values cannot be combined unless<br />

noted otherwise.<br />

9) Load values for 8d, 10d, 16d, and 20d designations in the<br />

fastener schedules throughout this catalogue refer to common<br />

wire nails unless noted otherwise. Nails shall conform<br />

to a recognized national standard, such as ASTM F1667, as<br />

prescribed by the model building codes.<br />

10) Diamond holes are for optional nailing.<br />

11) Fastener installation may cause wood to split and reduce<br />

a fastener’s ability to carry a load. If wood splitting occurs,<br />

consider pre-drilling holes not exceeding 75% of the nail<br />

diameter.<br />

12) Bolts specified in this catalogue are through-bolts and<br />

must conform to requirements for ASTM A 307 Grade A, or<br />

10<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Design Notes<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

1) Factored resistances for more than one direction for a<br />

single connection cannot be added together. A design load<br />

which can be divided into components in the directions given<br />

must be evaluated as follows:<br />

Factored uplift / Factored uplift resistance + Factored<br />

parallel to plate / Factored parallel to plate resistance +<br />

Factored perpendicular to plate / Factored perpendicular<br />

to plate


Installation Notes<br />

1) Use proper safety equipment during connector<br />

installations. Always wear gloves when handling connectors.<br />

2) All field welding should be done in accordance with CSA<br />

W59 Codes. Caution: Welding galvanized steel may produce<br />

harmful fumes and should only be performed in<br />

well-ventilated environments.<br />

3) The type and quantity of fasteners used to install <strong>USP</strong><br />

products is critical to connector performance. To achieve the<br />

factored resistance shown in this catalogue, install with the<br />

fasteners specified for that particular product. Some products<br />

allow for alternate nail installations. Refer to the “Optional<br />

Nails for Face Mount <strong>Hangers</strong>” chart on page 15 of this<br />

catalogue for load adjustments when using alternate nailing.<br />

All specified fasteners must be properly installed prior to<br />

applying load of any kind to the connection.<br />

4) Drill bolt holes a minimum of 1⁄32˝ and a maximum of 1⁄16˝<br />

larger than the diameter of the bolt to be installed. Per CSA<br />

O86-09 Clause 10.4.1.2.<br />

5) Washers should always be used under the head or nut of<br />

a bolt when not in contact with the connector unless noted<br />

otherwise.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

6) It is permissible to use nail guns to install connectors as<br />

long as the specified nails are installed through prepunched<br />

nail holes and all specified nail holes are filled. <strong>USP</strong><br />

recommends the use of nail guns featuring hole-locating<br />

mechanisms. Please note that many nail guns use fasteners<br />

smaller than the common nail size and load reductions will<br />

result. Contact <strong>USP</strong> or visit our Web Site for additional<br />

information. Caution: Always follow nail gun manufacturer’s<br />

safety guidelines.<br />

7) Joists installed in hangers should bear fully on the<br />

connector seat and shall be cut to fit against the header with<br />

a gap no greater than 1⁄8˝ between the joist end and header<br />

face.<br />

8) Multiple-ply members must be fastened securely together<br />

to act as one member.<br />

9) Top mount hangers shall be installed with the face of the<br />

hanger tight to the face of the header<br />

10) Top mount hangers installed in floor systems may<br />

produce unevenness. This may vary by the thickness of the<br />

hanger top flange steel and the nail heads. If a problem is<br />

anticipated, the effects can be mitigated by dapping the beam<br />

or cutting the subfloor at hanger locations. The use of face<br />

mount hangers will eliminate this problem.<br />

12<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Fasteners<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

Nails. . . . . . . . . . . . . . . . . . . . . . Pages 14-15<br />

• N & NA Series<br />

<strong>USP</strong> structural nails and common nail design information.<br />

Wood Screws . . . . . . . . . . . . . . Pages 16-19<br />

• WS Series<br />

<strong>USP</strong> self-drilling wood screws.<br />

• Wood Screw Applications<br />

Information on joining multiple ply truss, LVL, or<br />

PSL members.<br />

Lumberlok Screws . . . . . . . . . . . . . . Page 20<br />

• LL Series<br />

Self-drilling screws for a number of <strong>USP</strong> Structural <strong>Connectors</strong> and<br />

wood-to-wood applications.<br />

Bearing Plates . . . . . . . . . . . . . . . . . Page 20<br />

• BP & LBP Series<br />

Standard Bearing plates.<br />

• HBPS & LBPS Series<br />

Slotted bearing plates.<br />

NA<br />

WS<br />

LL<br />

Fasteners<br />

BP/LBP<br />

HBPS/LBPS<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 13<br />

<strong>USP</strong>2240-131


Nails – N & NA series<br />

Fasteners<br />

Proper fasteners are a critical component in a sound wood frame structure. To ensure successful installations of its connectors,<br />

<strong>USP</strong> offers a full range of structurally-rated nails. All galvanized nails supplied by <strong>USP</strong> are Hot-dipped for greater corrosion<br />

resistance. Any <strong>USP</strong> connector requiring a NA16D-RS or NA20D nail is shipped with the nails attached to the connector in<br />

convenient poly bags.<br />

Finish: See chart<br />

Materials: ASTM A 123; ASTM A 153 (HDG)<br />

Installation:<br />

• Factored shear values assume nail embedment into the wood of the entire nail or 8 nail diameters (whichever is less).<br />

• Load reductions may occur if nails are used other than those specified. See the chart Optional Nails for Face Mount <strong>Hangers</strong><br />

on page 15 for load reduction factors regarding nail substitutions.<br />

Minimum Fastener Penetration table<br />

Nail<br />

Penny<br />

Wire<br />

Gauge<br />

Shank<br />

Diameter<br />

(inches)<br />

Minimum<br />

Penetration<br />

for Full Load<br />

(inches)<br />

Minimum<br />

Penetration for<br />

Reduced Load 2<br />

(inches)<br />

6d 11-1/2 0.113 1.13 0.68<br />

8d 10-1/4 0.131 1.31 0.79<br />

10d 9 0.148 1.48 0.89<br />

16d Sinker 9 0.148 1.48 0.89<br />

12d 9 0.148 1.48 0.89<br />

16d 8 0.162 1.62 0.97<br />

20d 6 0.192 1.92 1.15<br />

1) Less than the specified nail penetration shall be<br />

multiplied by the applicable adjustment factor.<br />

2) For penetration less than this distance, the nail has no value.<br />

!<br />

Reduced Fastener Penetration<br />

Example (See chart on left):<br />

HD210 – listed load is 3820 lbs. @<br />

100% for 16d common nails.<br />

Reduced HD210 capacity if using a<br />

2x DF-L header:<br />

3820 lbs. x 1.5 = 3537 lbs. @ 100%<br />

1.62<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

Nail Specification table<br />

Metric (mm) Factored Shear Resistance 1,2,4,5<br />

<strong>USP</strong><br />

DF-L S-P-F<br />

Finish 3,6 Stock No. 7 Ref. No. Description (in) Dia Length Lbs kN Lbs kN<br />

NA11 N8 8d (0.131) x 1-1/2 3.33 38.1 178 0.79 163 0.72<br />

NA9D N10 10d (0.148) x 1-1/2 3.76 38.1 200 0.89 184 0.82<br />

HDG<br />

N10C 10DHDG 10d (0.148) x 3 3.76 76.2 218 0.97 201 0.90<br />

NA16D N16, N16EG 16d (0.162) x 2-1/2 4.11 63.5 250 1.11 230 1.02<br />

N16C 16DHDG 16d (0.162) x 3-1/2 4.11 88.9 250 1.11 230 1.02<br />

NA20D -- -- 20d (0.192) x 2-1/2 4.88 63.5 323 1.44 296 1.32<br />

N8-GC -- -- 8d (0.131) x 1-1/2 3.33 38.1 178 0.79 163 0.72<br />

GC<br />

N10-GC -- -- 10d (0.148) x 1-1/2 3.76 38.1 200 0.89 184 0.82<br />

N10C-GC -- -- 10d (0.148) x 3 3.76 76.2 218 0.97 201 0.90<br />

N16C-GC -- -- 16d (0.162) x 3-1/2 4.11 88.9 250 1.11 230 1.02<br />

SSNA8D SSN8 8d (0.131) x 1-1/2 3.33 38.1 178 0.79 163 0.72<br />

SSNA10D SSN10 10d (0.148) x 1-1/2 3.76 38.1 200 0.89 184 0.82<br />

SS SSN8C SS8D 8d (0.131) x 2-1/2 3.33 63.5 181 0.81 168 0.75<br />

SSN10C SS10D 10d (0.148) x 3 3.76 76.2 218 0.97 201 0.90<br />

SSN16C SS16D 16d (0.162) x 3-1/2 3.76 82.6 250 1.11 230 1.02<br />

8d Common -- -- 8d (0.131) x 2-1/2 3.33 63.5 181 0.81 168 0.75<br />

10d Common -- -- 10d (0.148) x 3 3.76 76.2 218 0.97 201 0.90<br />

16d Sinker -- -- 16d (0.148) x 3-1/4 3.76 82.6 218 0.97 201 0.90<br />

NA16D-RS -- -- 16d (0.148) x 3-1/2 Ring Shank 3.76 88.9 218 0.97 201 0.90<br />

<br />

16d Common -- -- 16d (0.162) x 3-1/2 4.11 88.9 250 1.11 230 1.02<br />

20d Common -- -- 20d (0.192) x 4 4.88 101.6 323 1.44 296 1.32<br />

-- -- 2.77 63.5 139 0.62 130 0.58<br />

-- -- 3.10 76.20 163 0.73 151 0.67<br />

-- -- 3.10 82.60 163 0.73 151 0.67<br />

-- -- 3.86 88.9 227 1.01 209 0.93<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

D <br />

<br />

red font.<br />

14<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

continued on next page


Nails – N & NA series continued<br />

NA11/NA8D N8-GC NA9D/NA10D<br />

.131 x 1 1/2˝ .131 x 1 1/2˝ .148 x 1 1/2˝<br />

N10-GC<br />

.148 x 1 1/2˝<br />

N10C<br />

.148 x 3˝<br />

N10C-GC<br />

.148 x 3˝<br />

NA16D-RS NA16D N16C N16C-GC NA20D<br />

.148 x 3 1/2˝ .162 x 2 1/2˝.162 x 3 1/2˝ .162 x 3 1/2˝ .192 x 2 1/2˝<br />

Fasteners<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

Optional Nails for Face Mount <strong>Hangers</strong><br />

(excludes slant nail hangers)<br />

Catalog<br />

Nail<br />

Replacement<br />

Fastener<br />

Resistance<br />

Adjustment Factor<br />

10d x 1-1/2 (0.148" x 1-1/2") 8d x 1-1/2 (0.131" x 1-1/2") 0.88<br />

8d common (0.131" x 2-1/2") 0.82<br />

10d common (0.148" x 3")<br />

10d spiral (0.122" x 3") 0.73<br />

12d common (0.148" x 3-1/4")<br />

10d x 1-1/2 (0.148" x 1-1/2") 0.90<br />

8d common (0.131" x 2-1/2") 0.71<br />

10d common (0.148" x 3") 0.86<br />

12d common (0.148" x 3-1/4") 0.86<br />

16d common (0.162" x 3-1/2'')<br />

10d spiral (0.122" x 3") 0.61<br />

12d spiral (0.122" x 3-1/4") 0.61<br />

16d spiral (0.152" x 3-1/2") 0.90<br />

10d x 1-1/2 (0.148" x 1-1/2") 0.78<br />

16d x 2-1/2 (0.162" x 2-1/2") 1.00<br />

1) This chart does not apply to hangers modified to skew and/or slope, or<br />

steel thinner than 14 gauge.<br />

2) This chart does not apply to HUS, JUS, MSH, MUS or THDH slant nail hangers.<br />

How to Use:<br />

The base value is the catalogue listed nail in<br />

Douglas Fir-Larch and the adjustment factor is the<br />

multiplier for the applicable replacement nail and<br />

wood combination.<br />

• Adjustment factors may vary with some custom<br />

hangers or steel thicker than 10 gauge. Contact<br />

<strong>USP</strong> for exceptions.<br />

• Roofing nails shall not be substituted for any nail<br />

size or type.<br />

!<br />

Optional Nails Example:<br />

JL210 – listed factored vertical resistance<br />

is 2180 lbs when connected onto<br />

SPF header, using 10d common nails.<br />

If substituting:<br />

8d common: 2180 lbs x 0.82 = 1787 lbs<br />

10d spiral: 2180 lbs x 0.73 = 1591 lbs<br />

10d x 1-1/2": 2180 lbs x 0.90 = 1962 lbs<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 15<br />

<strong>USP</strong>2240-131


Wood Screws – WS series<br />

Fasteners<br />

The WS Wood Screw is a self-drilling screw used for numerous framing<br />

applications. This screw features a reverse locking serration on the bottom of<br />

the screw head to help prevent over tightening against a steel plate. The <strong>USP</strong><br />

head stamp identifies screws for easy inspection.<br />

Screw shear capacities are based on a diameter of 0.242˝ when the shear plane<br />

is on the screw shank (SH) and 0.185˝ when the shear plane is on the knurl or<br />

threads (T). <strong>USP</strong> WS Wood Screws have a bending yield strength of 180,000<br />

psi.<br />

Materials:<br />

Finish:<br />

1/4˝ diameter Grade 5 steel<br />

See chart<br />

Installation:<br />

• Screws are self-drilling.<br />

• Install using a low speed clutch drill with 3/8˝ hex head driver. The washer<br />

head should be flat to the surface and the serrations will oppose turning and<br />

release the clutch. Do not over-tighten the screws.<br />

• Installing the screw at an angle may introduce additional bending and tension<br />

forces into the fastener if the screw head is not flat on the bearing surface. Care<br />

should be given to ensure the fastener is installed perpendicular to the plane of<br />

the side plate.<br />

L<br />

SH<br />

T<br />

WS<br />

Serrations<br />

1/4˝ Beveled reamer<br />

on 2 1 /2˝ or longer<br />

Wood Screws<br />

Cut threads<br />

Self drilling point<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

<strong>USP</strong> name<br />

Screw length<br />

For Attaching Multi-Ply Wood Trusses or<br />

LVL or PSL members, or floor trusses,<br />

see pages 17-19.<br />

3/8˝<br />

<strong>USP</strong><br />

Stock No.<br />

WS15<br />

WS15-GC<br />

WS2<br />

WS25<br />

WS3<br />

WS35<br />

WS45<br />

WS6<br />

Description<br />

Dimensions (in)<br />

Wood<br />

to Wood<br />

Factored Shear Resistance<br />

14 10 7 3<br />

10 7 3<br />

(DF-L<br />

Gauge Gauge Gauge Gauge<br />

(S-P-F<br />

Gauge Gauge Gauge Gauge<br />

Ref. No. in mm L SH T Finish 1 Unit to DF-L) 100% 100% 100% 100% to S-P-F) 100% 100% 100% 100%<br />

SDS25112<br />

-- --<br />

SDS25200<br />

SDS25212<br />

SDS25300<br />

SDS25312<br />

SDS25412<br />

SDS25600<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

6.1 x 38<br />

6.1 x 38<br />

6.1 x 50.8<br />

6.1 x 63.5<br />

6.1 x 76.2<br />

6.1 x 88.9<br />

6.1 x 114.3<br />

6.1 x 152.4<br />

1-1/2<br />

1-1/2<br />

2<br />

2-1/2<br />

3<br />

3-1/2<br />

4-1/2<br />

6<br />

1/4<br />

1/4<br />

1/4<br />

1/4<br />

3/4<br />

3/4<br />

1-1/4<br />

1-3/4<br />

1-1/4<br />

1-1/4<br />

1-3/4<br />

2<br />

2<br />

2-1/2<br />

3<br />

4<br />

Zinc<br />

GC<br />

Zinc<br />

Zinc<br />

Zinc<br />

Zinc<br />

Zinc<br />

Zinc<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

-- --<br />

-- --<br />

-- --<br />

323<br />

387<br />

452<br />

543<br />

543<br />

358<br />

358<br />

423<br />

487<br />

552<br />

616<br />

680<br />

680<br />

496<br />

496<br />

561<br />

625<br />

690<br />

754<br />

825<br />

825<br />

660<br />

660<br />

724<br />

789<br />

853<br />

918<br />

997<br />

997<br />

807<br />

807<br />

1031<br />

1031<br />

1031<br />

1031<br />

1031<br />

1031<br />

-- --<br />

-- --<br />

-- --<br />

277<br />

332<br />

387<br />

480<br />

480<br />

332<br />

332<br />

387<br />

443<br />

498<br />

553<br />

618<br />

618<br />

471<br />

471<br />

526<br />

582<br />

637<br />

692<br />

763<br />

763<br />

635<br />

635<br />

691<br />

746<br />

801<br />

857<br />

890<br />

890<br />

692<br />

692<br />

900<br />

900<br />

900<br />

900<br />

900<br />

900<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

-- --<br />

-- --<br />

-- --<br />

1.44<br />

1.72<br />

2.01<br />

2.42<br />

2.42<br />

1.59<br />

1.59<br />

1.88<br />

2.17<br />

2.46<br />

2.74<br />

3.02<br />

3.02<br />

2.21<br />

2.21<br />

2.49<br />

2.78<br />

3.07<br />

3.36<br />

3.67<br />

3.67<br />

2.93<br />

2.93<br />

3.22<br />

3.51<br />

3.80<br />

4.08<br />

4.44<br />

4.44<br />

3.59<br />

3.59<br />

4.58<br />

4.58<br />

4.58<br />

4.58<br />

4.58<br />

4.58<br />

-- --<br />

-- --<br />

-- --<br />

1.23<br />

1.48<br />

1.72<br />

2.14<br />

2.14<br />

1.48<br />

1.48<br />

1.72<br />

1.97<br />

2.21<br />

2.46<br />

2.75<br />

2.75<br />

2.09<br />

2.09<br />

2.34<br />

2.59<br />

2.83<br />

3.08<br />

3.40<br />

3.40<br />

2.83<br />

2.83<br />

3.07<br />

3.32<br />

3.56<br />

3.81<br />

3.96<br />

3.96<br />

3.08<br />

3.08<br />

4.00<br />

4.00<br />

4.00<br />

4.00<br />

4.00<br />

4.00<br />

DF-L 2,3,4,5<br />

Steel to Wood<br />

1) Zinc = Yellow zinc dichromate; GC = Gold Coat.<br />

2) Factored Resistance values determined in accordance with CSA O86-09 Section 10.11.<br />

3) Steel side plate factored resistance based on a minimum Fu = 45,000 psi.<br />

<br />

5) Loads are for 100% duration of load factors, and may be increased for other duration factors allowed per governing building code.<br />

6) Loads are for shear applications when used as described in this catalog. Please contact <strong>USP</strong> for applications and installations involving tension forces.<br />

New products or updated product information are designated in red font.<br />

Wood<br />

to Wood 14<br />

S-P-F 2,3,4,5<br />

Steel to Wood<br />

16<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Wood Screw Applications – WS series<br />

Joining 2, 3, or 4 Ply Wood Trusses<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

The installation instructions and design example shown below are intended for a design professional who will be<br />

responsible for determining the location and number of wood screws to adequately transfer all loads on the truss.<br />

Installation:<br />

• Screw spacing shall not be greater than 24˝ on centre and less than 4˝ on centre. However, the location of any<br />

individual screw may be adjusted up to one-half the required screw spacing to avoid lumber defects or interference<br />

with other hardware.<br />

• Load or hanger spacing shall not be greater than 24˝ centre-to-centre.<br />

• The last truss ply must have a minimum of 11/4˝ of screw penetration and no more than 1/8˝ gap between each ply.<br />

• Screws cannot be installed through metal truss plates unless the Truss Engineer approves predrilling.<br />

• On 2x4 members, use one row of wood screws. On 2x6 and 2x8 use two rows, and on 2x10 use three rows. Stagger<br />

all rows.<br />

• The truss bottom chord shall have lateral bracing installed as called out by the Truss Engineer to prevent any<br />

displacement from torsional forces.<br />

• Install screws from one side<br />

without flipping the truss.<br />

• Top and bottom chords<br />

require screws and in some<br />

cases the webs may require<br />

screws.<br />

• All lateral bracing should be<br />

attached to each truss ply.<br />

• Increase edge and end<br />

distances if wood splitting<br />

occurs.<br />

2 1 /2˝ Min.<br />

1 1 /2˝ Min.<br />

Start screws on<br />

face that carries<br />

hanger on load<br />

Spacing<br />

4˝ min. – 24˝ max.<br />

1˝ min. Recommended (Typ)<br />

Spacing<br />

4˝ min. – 24˝ max.<br />

4˝ min<br />

1 1 /2˝ Min.<br />

End of<br />

chord<br />

Fasteners<br />

Description<br />

Length (in)<br />

Factored Shear Loads (100%.) 1,2,3<br />

Shear<br />

S-P-F<br />

<strong>USP</strong><br />

Plane<br />

DF-L<br />

Stock No. Ref. No. in mm L SH T Finish Location Lbs kN Lbs kN<br />

WS3 SDS25300 3 3/4 2 Zinc SH, T 387 1.72 332 1.48<br />

WS45 SDS25412 3 Zinc SH, T 543 2.42 480 2.14<br />

WS6 SDS25600 6 4 Zinc SH, T 543 2.42 480 2.14<br />

<br />

2) The Truss Engineer shall apply all applicable adjustment factors.<br />

<br />

<br />

New products or updated product information are designated in red font.<br />

3 Ply with Mixed Wood Species:<br />

Bottom Chord: 2x6 Douglas Fir-Larch<br />

Top Chord: 2x4 Spruce-Pine-Fir<br />

WS45 Wood Screw Factored Resistance:<br />

(Assume shear plane across the screw shank)<br />

Douglas Fir-Larch: 543 Ibs. each at 100%<br />

Spruce-Pine-Fir: 480 lbs. each at 100%<br />

Design Example<br />

Truss top chord<br />

Required Loads:<br />

Bottom Chord Load: 500 plf<br />

Top Chord Load: 60 plf<br />

Bottom Chord Wood Screw Spacing:<br />

Using 2 rows of WS45 Wood Screws in 2x6<br />

2 x 543/500 x<br />

# Plies<br />

= 3.26 ft.<br />

# Plies - 1<br />

Use maximum spacing of 24˝.<br />

Top Chord Wood Screw Spacing:<br />

Only 1 row of WS45 Wood Screws in 2x4 member<br />

1 x 480/60 x<br />

# Plies<br />

= 12.0 ft.<br />

# Plies - 1<br />

Use maximum spacing of 24˝.<br />

Truss bottom chord<br />

Truss span<br />

Typical Truss Profile (profile may vary)<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 17<br />

<strong>USP</strong>2240-131


Wood Screw Applications – WS series continued<br />

Fasteners<br />

Joining 2, 3, or 4 Ply LVL or PSL Members<br />

Installation Notes:<br />

• For 2 ply members, wood screws shall be installed with<br />

the screw heads in the loaded ply.<br />

• For 3 or 4 ply members, wood screws shall be installed in<br />

both outer plies.<br />

• Designer shall specify all wood screws locations.<br />

• Increase edge and end distances if wood splitting occurs.<br />

• Stagger all screws installed into the opposite face.<br />

• A minimum of 2 rows of screws shall be used for all<br />

members with H = 5 1/2˝ and larger.<br />

Dimensions (in)<br />

Maximum Allowable Uniform Loads<br />

Multiple<br />

Members<br />

<br />

that can be applied to either outside member 1,2,3,4,5,6<br />

LVL/PSL (S.G. = 0.46)<br />

Wood Screw Spacing<br />

<br />

<br />

<strong>USP</strong><br />

Installation 2 Rows 3 Rows<br />

2 Rows 3 Rows 2 Rows 3 Rows<br />

Stock No. Ref. No. Description (in) L SH T Figure 3,9,10 Lbs/ft kN/m Lbs/ft kN/m Lbs/ft kN/m Lbs/ft kN/m Lbs/ft kN/m Lbs/ft kN/m<br />

1 1695 24.74 2545 37.14 1130 16.49 1695 24.74 850 12.40 1270 18.53<br />

WS35 SDS25312 3-1/2 3/4 2-1/2<br />

2 1270 18.53 1910 27.87 850 12.40 1270 18.53 635 9.27 955 13.94<br />

4 1270 18.53 1910 27.87 850 12.40 1270 18.53 635 9.27 955 13.94<br />

5 1130 16.49 1695 24.74 755 11.02 1130 16.49 565 8.25 850 12.40<br />

WS6 8 SDS25600 6 1-3/4 4<br />

3 1455 21.23 2185 31.89 970 14.16 1455 21.23 730 10.65 1090 15.91<br />

6 5100 74.43 7640 111.50 3400 49.62 5100 74.43 2550 37.21 3820 55.75<br />

1) Factored Resistance values determined in accordance with CSA O86-09 Clause 10.11.<br />

<br />

<br />

4) Except for Figure 6 installation, load values neglect any contribution of screws installed to opposite side, even if they extend significantly into the loaded ply.<br />

<br />

<br />

<br />

<br />

<br />

<br />

red font.<br />

L<br />

SH<br />

T<br />

Serrations<br />

1/4˝ Beveled reamer<br />

on 2 1/2˝ or longer<br />

Wood Screws<br />

Cut threads<br />

Self drilling point<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6<br />

WS35 installed<br />

in (2) 13/4˝ Ply<br />

WS35 installed<br />

in (3) 13/4˝ Ply<br />

WS6 installed<br />

in (4) 13/4˝ Ply<br />

WS35 installed<br />

in (1) 13/4˝,<br />

(1) 31/2˝ Ply<br />

WS35 installed<br />

in (2) 13/4˝,<br />

(1) 31/2˝ Ply<br />

WS6 installed<br />

in (2) 31/2˝ Ply<br />

Recommended Row Guidelines<br />

1˝ min. Recommended (Typ)<br />

Other Stagger patterns as approved by Engineer are acceptable<br />

1 1 /2˝<br />

min<br />

18<br />

H<br />

2 1 /2˝<br />

min<br />

2 1 /2˝<br />

min<br />

1 1 /2˝<br />

min<br />

Spacing<br />

4˝ min. – 24˝ max.<br />

Spacing<br />

4˝ min. – 24˝ max.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

4˝ min<br />

End of member<br />

continued on next page


Wood Screw Applications – WS series continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

Joining 2 Ply 4x2 Floor Trusses<br />

The following information pertains to the use of the <strong>USP</strong>’s WS6 Wood Screws to fasten together a two-ply 4x2 floor truss<br />

girder, such that the induced loads are supported by both truss plies. Screw spacing and the location of each specific<br />

screw may vary depending on the design criteria for each application, and therefore must be determined by the truss or<br />

building designer. However, in the determination of screw locations, the following criterion shall also be considered.<br />

These criterion are varying dependent upon how trusses are loaded as follows:<br />

Uniform/Distributed Load<br />

• Screws shall be installed into the top chord with a horizontal<br />

spacing between screws of not less than 4-inches on centre and<br />

not more than 24-inches on centre.<br />

• A minimum end distance of 4-inches must be maintained. If<br />

necessary, additional screws may be installed in the bottom chord.<br />

• Centre screw vertically on 11/2˝ dimension of top chord. If<br />

splitting occurs, it may be necessary to pre-drill the holes in<br />

accordance with the code.<br />

• The screws shall be installed with the headed end of the screw<br />

on the loaded truss. If either ply is “the loaded truss”, the screws<br />

shall be divided between the two plies, with the spacing on each<br />

side twice the minimum indicated above.<br />

• The screws shall not be installed through the metal truss plates,<br />

unless approved by the truss designer and the plates are<br />

pre-drilled, on each side to a 1/4-inch diameter. Do not drill through<br />

the wood.<br />

• The maximum gap between the wood members of the two<br />

trusses shall be 1/8-inch.<br />

• The truss designer shall design the truss members with the<br />

capacity and capability of the screws in mind, and shall meet all<br />

provisions of the code and ANSI/TPI.<br />

• Individual screw locations may need to be adjusted to avoid<br />

conflicts with connectors, problematic wood or other framing<br />

members. Adjustments should follow the criteria described in this<br />

section.<br />

Concentrated/Point Load<br />

The placement of fasteners for concentrated loading includes all<br />

requirements of uniform loading with the additional following<br />

criteria:<br />

• Loads must occur over a vertical member, and the necessary<br />

concentration of screws shall be installed in the vertical member.<br />

• Additional screws may be installed on the top chord and<br />

adjacent web members if necessary.<br />

• The fasteners should be grouped as close to the concentrated<br />

load as possible, but satisfy the same minimum spacing<br />

indicated for uniform loading.<br />

• In no case shall the required group of fasteners extend beyond<br />

12-inches from the location of the concentrated load.<br />

Uniform/Distributed Load<br />

Applied distributed load<br />

WS6 Wood Screws<br />

WS6 Wood Screw<br />

Additional<br />

WS6 Wood Screw<br />

if necessary<br />

Concentrated/Point Load<br />

12˝<br />

max<br />

Applied Concentrated Load<br />

Applied Concentrated Load<br />

12˝<br />

max<br />

Fasteners<br />

Truss Members<br />

3 1 /2˝<br />

3 1 /2˝ 5/8˝ - 7 /8˝<br />

Factored Shear Loads (100%) 1<br />

<strong>USP</strong><br />

DF-L<br />

S-P-F<br />

Stock No. Ref. No. Lbs kN Lbs kN<br />

WS6 SDS25600 672 2.99 591 2.63<br />

1) Factored Resistance values determined in accordance<br />

with CSA O86-09 Clause 10.11.<br />

New products or updated product information are<br />

designated in red font.<br />

1 1 /2˝<br />

Screw Detail<br />

Typ. @ all<br />

members<br />

WS6 Wood Screw<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 19<br />

<strong>USP</strong>2240-131


Lumberlok Structural Connector Screws - LL series<br />

Fasteners<br />

The LumberLok Structural Connector Screw is a self-drilling screw that can be<br />

used with a number of <strong>USP</strong> Structural <strong>Connectors</strong> and also for wood-to-wood<br />

applications. The screws feature a T20 Torx® head with integral washer and<br />

gimlet point for ease of installation. The twin-lead threads drive in twice as fast<br />

as the single lead threads significantly reducing installation time. The <strong>USP</strong><br />

head stamp identifies the screw length for easy inspection.<br />

Screw shear capacities are based on a diameter of 0.162” when the shear plane<br />

is on the screw shoulder (SH) and 0.109” when the shear plane is on the<br />

threads (T). LumberLok Structural Connector Screws have a bending yield<br />

strength of 180,000 psi.<br />

T20 Torx ®<br />

head<br />

Screw<br />

length<br />

Materials: Low carbon hardened steel.<br />

Finish: See chart<br />

Installation:<br />

• Screws are self-drilling.<br />

• Install using a low speed clutch drill with T20 Torx® bit. The washer head<br />

should be flat to the surface. Do not over-tighten the screws.<br />

• Installing the screw at an angle may introduce additional bending and tension<br />

forces into the fastener if the screw head is not flat to the bearing surface. Care<br />

should be given to ensure the fastener is installed perpendicular to the plane of<br />

the fastener hole.<br />

LL915<br />

SH<br />

L<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Dimensions (in.)<br />

<strong>USP</strong><br />

Wood-to- Withdrawal<br />

Shear<br />

Wood-to- Withdrawal<br />

Shear<br />

Stock No. Ref. No. Description L SH T Finish 2 Unit Wood Capacity 18 Ga 16 Ga Wood Capacity 18 Ga 16 Ga<br />

LL915<br />

LL930<br />

SD9112<br />

SD9212<br />

#9 x 1-3/8<br />

#9 x 2-7/8<br />

1-3/8<br />

2-7/8<br />

1/4<br />

1-3/8<br />

1-1/8<br />

1-1/2<br />

GC<br />

GC<br />

Lbs<br />

Lbs<br />

-- --<br />

228<br />

237<br />

288<br />

190<br />

249<br />

208<br />

265<br />

-- --<br />

196<br />

180<br />

219<br />

173<br />

226<br />

191<br />

243<br />

kN<br />

kN<br />

-- --<br />

1.01<br />

1.05<br />

1.28<br />

0.85<br />

1.11<br />

0.93<br />

1.18<br />

-- --<br />

0.87<br />

0.80<br />

0.97<br />

0.77<br />

1.01<br />

0.85<br />

1.08<br />

1) Factored Resistance values determined in accordance with CSA O86-09 Section 10.11.<br />

2) GC = Gold Coat over Clear Zinc Trivalent.<br />

3) Factored shear resistance for steel-to-wood assumes a side plate tensile strength of 45 ksi.<br />

4) Withdrawal loads for steel-to-wood connections assume a side plate thickness of 1 / 4 " or less.<br />

5) Shear loads for wood-to-wood connections assume a side member thickness of 1 1 / 2 ".<br />

6) Loads are for 100% duration of load factors, and may be increased for other duration factors allowed per governing building code.<br />

New products or updated product information are designated in red font.<br />

Shear<br />

Factored Resistance (100%) ,3,4,5,6<br />

DF-L<br />

Steel-to-Wood<br />

Shear<br />

S-P-F<br />

Steel-to-Wood<br />

Twin-lead<br />

threads<br />

Sharp Gimlet<br />

point<br />

LL930<br />

T<br />

BEARING PLATES – BP, HBPS, LBP, & LBPS SERIES<br />

20<br />

BP & LBP – Designed to meet code requirements for mudsill-to-foundation.<br />

HBPS & LBPS – Offers anchor bolt adjustment slots.<br />

Materials: See chart<br />

Finish: BP & HBPS – none;<br />

LBP & LBPS – G-185 galvanizing<br />

Options: BP12, BP582, BP583, HBPS12, and HBPS58<br />

models are available in Hot-dip galvanized.<br />

To order, add HDG to end of stock number,<br />

as in BP12-HDG.<br />

Installation:<br />

• Bolt holes are sized 1⁄16˝ larger than Bolt Dia. shown in chart.<br />

Typical Bearing<br />

Plate installation<br />

W<br />

BP/LBP<br />

Standard<br />

Bearing Plate<br />

L<br />

PT T<br />

W<br />

HBPS/LBPS<br />

Slotted Bearing Plate<br />

L<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

Dimensions (in)<br />

<strong>USP</strong><br />

Stock No. Ref. No.<br />

Plate<br />

Thickness<br />

(T)<br />

W L<br />

Bolt<br />

Dia.<br />

(in)<br />

LBP12-TZ<br />

LBP1/2,<br />

LBP1/2Z<br />

10 Ga 9/64 2 2 1/2<br />

LBP58-TZ<br />

LBP5/8,<br />

LBP5/8Z<br />

10 Ga 9/64 2 2 5/8<br />

LBPS12-TZ<br />

LBPS1/2,<br />

LBPS1/2Z<br />

10 Ga 9/64 3 3 1/2<br />

LBPS58-TZ<br />

LBPS5/8,<br />

LBPS5/8Z<br />

10 Ga 9/64 3 3 5/8<br />

HBPS12 BPS1/2-3 3 Ga 1/4 3 3 1/2<br />

HBPS34 BPS3/4-3 3 Ga 1/4 3 3 3/4<br />

HBPS58 BPS5/8-3 3 Ga 1/4 3 3 5/8<br />

BP12 BP1/2 7 Ga 3/16 2 2 1/2<br />

BP582 BP5/8-2 7 Ga 3/16 2 2 5/8<br />

BP583<br />

BP5/8,<br />

BP5/8-3<br />

3 Ga 1/4 3 3 5/8<br />

BP343 BP3/4-3 3 Ga 1/4 3 3 3/4


Concrete & Masonry<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

®<br />

EPOXY & MECHANICAL<br />

ANCHORING SYSTEMS. . . . . . . . . . . . . . . PAGES 23-26<br />

• CIA-GEL 7000-C Series<br />

Code compliant epoxy.<br />

• CIA-GEL 7000 Series<br />

Masonry approved epoxy.<br />

• CIA-GEL 6000-GP Series<br />

General purpose, quick cure epoxy.<br />

• CIA-EA Series<br />

Epoxy acrylate structural adhesive.<br />

• Miracle Bond ®<br />

Multi-purpose bonding and repair epoxy.<br />

• DUC Series<br />

Ductile Undercut Anchors.<br />

• Wedge-Bolt ® + Series<br />

Screw anchor.<br />

• Power-Stud HD5 Series<br />

Expansion anchor.<br />

Masonry Metals . . . . . . . . . . Pages 27-29<br />

• SAL Series<br />

Steel angle lintels.<br />

• WM Series<br />

Welded wire mesh.<br />

• CR Series<br />

Concrete reinforcing rod.<br />

• TW Series & TWTT<br />

Tie Wire and Tie Wire Tying Tool.<br />

• RCD & RCT<br />

Rod chairs hold reinforcing bars for proper placement during the<br />

pouring or application of concrete.<br />

• SCV & SCH<br />

Safety caps to protect against injuries from rebar.<br />

• ABS12<br />

Anchor bolt stabber for placement in wet concrete.<br />

• THR Series<br />

Threaded rod.<br />

• CRE24<br />

Epoxy coated rebar.<br />

• NSR<br />

Nail stake secures form boards to prevent movement and bowing.<br />

CIA-GEL 7000-C CIA-GEL 7000 CIA-GEL 6000-GP<br />

CIA-EA<br />

Miracle Bond ®<br />

DUC<br />

DUCSB<br />

Wedge-Bolt ® +<br />

Power-Stud HD5<br />

SAL<br />

WM48<br />

CR<br />

TW TWTT RCD RCT<br />

SCV<br />

SCH CRE24 ABS12<br />

Concrete & Masonry<br />

• RP6<br />

Oversized plate to distribute forces on masonry surface.<br />

THR<br />

NSR<br />

RP6<br />

Concrete Form Ties & Wedge . . . Page 30<br />

• FT Series<br />

Low foundation wall tie.<br />

• WG<br />

Wedge for FT tie.<br />

• RKS<br />

Kwik strip tie for foundation applications.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

21<br />

<strong>USP</strong>2240-131<br />

FT<br />

RKS<br />

WG


Concrete & Masonry<br />

Anchor Bolts. . . . . . . . . . . . . . Pages 31-33<br />

• STB & STBL Series<br />

<strong>USP</strong> anchor bolts designed for higher capacity<br />

applications.<br />

• AB & ABP Series<br />

<strong>USP</strong> anchor bolts designed for general capacity<br />

applications.<br />

STB/STBL AB ABP<br />

L<br />

Concrete & Masonry<br />

Foundation Anchors . . . . . . . Pages 33-35<br />

• SFA & SFJA<br />

Bolted mudsill anchors for retro-fit applications.<br />

• FA3<br />

Embedded mudsill and stud anchors.<br />

• ST Series<br />

Embedded mudsill anchors.<br />

Laminated Beam Seats . . . . . . . . . Page 36<br />

• KGLB, KGLBT, & KHGLB Series<br />

Seats for beams bearing on concrete or masonry.<br />

SFA SFJA FA3 ST1-TZ<br />

KGLB KGLBT<br />

ST2-TZ<br />

KHGLB<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

®<br />

Jack Posts . . . . . . . . . . . . . . . Pages 37-39<br />

• JP Series<br />

Light-duty adjustable support post.<br />

• Type 2 Series<br />

Heavy-duty adjustable support post for maximum loads.<br />

JP Type 2<br />

22<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


ADHESIVE ANCHORING SYSTEMS<br />

CIA-GEL 7000-C EPOXY − GEL7C SERIES<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

CIA-GEL 7000-C Epoxy is an adhesive designed to attach anchor bolts into concrete that is, or may<br />

become, cracked due to cyclic loading from wind or earthquakes. It may also be used with fully grouted<br />

CMU construction. It is a low odor, solvent free, non-shrink, non-sag adhesive. The two-component<br />

(resin and hardener) epoxy is supplied in equal volume cartridges, which are combined in a 1:1<br />

ratio when dispensed through the attached mixing nozzle. Either a hand powered or air-powered<br />

dispenser may be used. The cartridges are sealed with a D-plug which opens easily on the jobsite<br />

and allows partially used cartridges to be saved for later use. The epoxy has a two year shelf life when<br />

stored in unopened containers at temperatures between 10ºC/50ºF and 25ºC/77ºF.<br />

Applications:<br />

• Anchors All-Thread rod and deformed rebar into concrete<br />

• Hold downs into concrete for high seismic zones<br />

• Horizontal and overhead anchoring applications (requires special inspection)<br />

CIA-GEL 7000 EPOXY − GEL7 SERIES<br />

NEW<br />

CIA-GEL 7000 Epoxy is a structural adhesive specifically designed to attach anchor bolts into fully<br />

grouted concrete masonry units (CMU) and evaluated for seismic, sustained load, elevated temperature<br />

and freeze-thaw suitability conditions. It can also be used to install anchor bolts into uncracked<br />

concrete and reinforced brick. It is a low odor, solvent free, non-shrink adhesive. The two-component<br />

(resin and hardener) epoxy is supplied in equal volume cartridges, which are combined in a 1:1 ratio<br />

when dispensed through the attached mixing nozzle. Either a hand powered or air-powered dispenser<br />

may be used. The cartridges are sealed with a D-plug which opens easily on the jobsite and allows<br />

partially used cartridges to be saved for later use. The epoxy has a one year shelf life when stored in<br />

unopened containers at a temperature of 21ºC/70ºF.<br />

Applications:<br />

• Anchors All-Thread rod and deformed rebar into fully grouted CMU<br />

• Brick veneer anchoring<br />

• Crack injection of medium to wide cracks<br />

• Anchors rebar and All-Thread rod into uncracked concrete<br />

NEW<br />

Available in:<br />

10 oz. – GEL7C-10<br />

22 oz. – GEL7C-22<br />

Available in:<br />

10 oz. – GEL7-10<br />

22 oz. – GEL7-22<br />

Concrete & Masonry<br />

CIA-GEL 6000-GP EPOXY − GEL6GP-22<br />

CIA-GEL 6000-GP is a superior epoxy specifically designed for general purpose structural applications<br />

that require quick load times and for doweling applications. It is a two-component (1:1 ratio)<br />

adhesive epoxy with 100% solids and is solvent free, moisture insensitive, non-sag and has no odor.<br />

It provides exceptional strength in anchoring and doweling applications and can be used in temperatures<br />

between 1ºC/35°F and 45ºC/115°F. The epoxy has a two year shelf life when stored in<br />

unopened containers at temperatures between 4ºC/40°F and 35ºC/95°F.<br />

Applications:<br />

• Doweling applications for rebar and tie bars for full depth concrete pavement repairs<br />

• Anchoring and bracing for short term tensile load where dynamic, vibratory, wind or<br />

intermittent loads exist<br />

• Use in concrete, grout filled block and unreinforced masonry for general purpose<br />

anchoring and doweling applications<br />

• Concrete doweling road repairs<br />

NEW<br />

Available in:<br />

22 oz. – GEL6GP-22<br />

See Anchoring Solutions Catalog or visit www.uspconnectors.com/epoxyindex.shtml for more information<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

23<br />

<strong>USP</strong>2240-131


ADHESIVE ANCHORING SYSTEMS<br />

CIA-EA EPOXY ACRYLATE − EA SERIES<br />

Concrete & Masonry<br />

CIA-EA Adhesive Anchoring System is an epoxy acrylate specifically designed to be a high strength,<br />

fast cure structural adhesive for anchoring threaded rod and deformed rebar into uncracked concrete.<br />

It has the added advantage of being formulated to be used in colder temperatures (0°C/32°F) while<br />

maintaining excellent flowability. CIA-EA may also be used with fully grouted CMU and reinforced<br />

brick construction. It is a 2-component, 100% solids, moisture insensitive adhesive that is ideally suited<br />

for a wide range of applications. It is composed of a proprietary blend of solvent free epoxy acrylate<br />

resin and is backed by independent research and testing. The epoxy has a 15 month shelf life<br />

when stored in unopened containers at temperatures between 5°C/41°F to 25°C/77°F.<br />

Applications:<br />

• Anchors All-Thread rod into concrete<br />

• May also be used to anchor rebar, started bars and dowels<br />

• Applications requiring fast cure times<br />

• Cold weather applications<br />

• Can be used in horizontal anchoring applications<br />

• Can be used in overhead anchoring applications (requires special inspection)<br />

NEW<br />

Available in:<br />

10 oz. – EA-10<br />

28 oz. – EA-28<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

MIRACLE BOND® EPOXY − MB-9<br />

Miracle Bond® is a high strength two-component epoxy specifically designed to be a bonding agent for<br />

almost all household materials including wood, steel, concrete, brick, stone and CMU block. It is moisture<br />

insensitive and can also be used to fill cracks in concrete, block and stone. The epoxy has a 2 year<br />

shelf life when stored in unopened containers in dry conditions between 4°C/40°F to 35°C/95°F.<br />

Applications:<br />

• Bonding applications for:<br />

Concrete<br />

Brick<br />

CMU block<br />

Stone<br />

Metal<br />

Wood<br />

• Repair vertical and overhead cracks in concrete (non-structural)<br />

• Repair vertical and overhead spalls in concrete (5/8” deep & 3” diameter max)<br />

• Non-sag consistency makes this ideal for corner repairs to concrete and block walls<br />

• Repair and replace brick<br />

• Replace pool tile (no need to empty pool)<br />

• Fill holes and cracks<br />

NEW<br />

Available in:<br />

8.6 oz. – MB-9<br />

24<br />

See Anchoring Solutions Catalog or visit www.uspconnectors.com/epoxyindex.shtml for more information<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Undercut Anchoring Systems - DUC Ductile Undercut Anchors<br />

Mechanical anchor expanded into a hole that has been undercut at the<br />

bottom using an undercutting drill bit creating a true bearing type anchor<br />

that performs like a cast-in-place headed anchor. Load is transferred into<br />

the concrete through bearing, not friction like traditional expansion<br />

anchors. Excellent performance in seismic and dynamic loading<br />

conditions. Meets ACI 318-02 Appendix D requirements as a code<br />

anchor, including seismic loading, tension zone, and cracked concrete<br />

provisions.<br />

DUC<br />

Undercut Anchor<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Rod Materials: ASTM A36 (L Series), A193 Grade B7<br />

(H Series), or AISI 316 Stainless Studs<br />

Anchor Body Materials: ASTM A 513 Type 5, or AISI 316 Stainless<br />

Installation:<br />

UCB<br />

Undercut Drill Bit<br />

Concrete & Masonry<br />

Drill the hole to<br />

proper depth<br />

and diameter<br />

per specifications<br />

using<br />

rotohammer<br />

and stop drill.<br />

Clean the<br />

hole using a<br />

blow-out bulb<br />

or compressed<br />

air.<br />

Insert the<br />

undercut bit<br />

and start the<br />

rotohammer.<br />

Undercutting is<br />

complete when<br />

the stopper<br />

sleeve is fully<br />

compressed<br />

(gap closed).<br />

Clean the hole<br />

again using a<br />

blow-out bulb<br />

or compressed<br />

air.<br />

Insert anchor<br />

into hole. Place<br />

setting sleeve<br />

over anchor<br />

and drive the<br />

expansion<br />

sleeve over<br />

the expansion<br />

coupling.<br />

Verify that the<br />

setting mark<br />

is visible on<br />

the threaded<br />

rod above the<br />

sleeve.<br />

Apply proper<br />

torque.<br />

lb<br />

dc<br />

db<br />

Tension and Shear Capacities for DUC<br />

Anchors in f’c > 2,500 psi concrete<br />

hef<br />

ho<br />

<strong>USP</strong><br />

Stock No.<br />

DUC38-275L<br />

DUC38-275LT<br />

DUC38-400H<br />

DUC38-400HT<br />

DUC12-400L<br />

DUC12-400LT<br />

DUC12-500H<br />

DUC12-500HT<br />

DUC12-675H<br />

DUC12-675HT<br />

DUC58-450L<br />

DUC58-450LT<br />

DUC58-750H<br />

DUC58-750HT<br />

DUC58-900H<br />

DUC58-900HT<br />

DUC34-500L<br />

DUC34-500LT<br />

DUC34-1000H<br />

DUC34-1000HT<br />

Rod Dia. d b<br />

Expansion<br />

Coupling Dia. d c<br />

Drilled Hole<br />

Depth of Stop Bit h o<br />

Anchor<br />

Length, l b<br />

in mm in mm in mm in mm in mm Lbs kN Lbs kN<br />

3-1/8 79.4 2-3/4 69.9 5-1/2 139.7 4650 20.69 2790 12.41<br />

3/8 9.5 5/8 15.9<br />

4-3/8 111.1 4 101.6 6-3/4 171.5 9690 43.10 5815 25.87<br />

1/2<br />

5/8<br />

3/4<br />

12.7<br />

15.9<br />

19<br />

3/4<br />

1<br />

1-1/8<br />

19<br />

25.4<br />

28.6<br />

1) Factored resistance and shear capacities are for anchors installed at standard edge distance and spacing in<br />

uncracked concrete. For cracked concrete capacities, see the <strong>USP</strong> Anchoring Systems Design Guide.<br />

4-1/4<br />

5-1/4<br />

7<br />

5<br />

8<br />

9-1/2<br />

5-7/8<br />

10-7/8<br />

107.9<br />

133.4<br />

177.8<br />

127<br />

203.2<br />

Effective<br />

Embedment h ef<br />

4<br />

5<br />

6-3/4<br />

4-1/2<br />

7-1/2<br />

114.3<br />

190.5<br />

7<br />

8<br />

9-3/4<br />

7-3/4<br />

10-3/4<br />

13-5/8<br />

177.8<br />

203.2<br />

247.6<br />

196.9<br />

273.1<br />

241.3 9 228.6 12-1/4 311.2<br />

149.2<br />

276.2<br />

5<br />

10<br />

101.6<br />

127<br />

171.5<br />

127<br />

254<br />

8-5/8 219.1<br />

346.1<br />

Ultimate<br />

Tensile<br />

Capacity, N s<br />

8515 37.88 5110<br />

17740<br />

13560<br />

78.91<br />

60.32<br />

28250 125.67 16950<br />

Ultimate<br />

Shear<br />

Capacity, V s<br />

10645<br />

8135<br />

20040 89.15 12025<br />

41750 185.72 25050<br />

22.73<br />

47.35<br />

36.19<br />

75.40<br />

53.49<br />

111.43<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

25<br />

<strong>USP</strong>2240-131


MECHANICAL ANCHORS - WEDGE-BOLT®+ SERIES<br />

Concrete & Masonry<br />

The Wedge-Bolt ® + anchor is a<br />

one piece, heavy duty screw<br />

anchor with a finished hex<br />

head. It is simple to install, easy<br />

to identify and fully removable.<br />

The Wedge-Bolt ® + has features<br />

and benefits that make it well<br />

suited for many applications.<br />

The steel threads along the<br />

anchor body tap into the hole<br />

during installation to provide key<br />

engagement. Suitable base<br />

materials include normal-weight<br />

concrete, structural sand-lightweight<br />

concrete, concrete over<br />

steel deck, concrete masonry<br />

and solid clay brick. The anchor<br />

is designed for structural loading<br />

in cracked and uncracked<br />

concrete.<br />

NEW<br />

Wedge-Bolt ® +<br />

<strong>USP</strong><br />

Anchor<br />

<strong>USP</strong><br />

Anchor<br />

<strong>USP</strong><br />

Usable<br />

Finish<br />

Stock No. 2<br />

Ref. No.<br />

Size (in) 1<br />

Finish<br />

Stock No. 2<br />

Ref. No.<br />

Size (in) 1<br />

7204SD -- -- 1/4 x 1-1/4 7282SD THD75400H 3/4 x 4 1314 SDS 1/4" x 6" 4"<br />

7206SD THD25134H 1/4 x 1-3/4 7284SD THD75500H 3/4 x 5 1318 SDS 3/8" x 8" 6"<br />

Zinc<br />

7208SD THD25214H 1/4 x 2-1/4 7286SD THD75600H 3/4 x 6 1384 HD Straight Shank 3/8" x 13" 4"<br />

Plated<br />

7210SD THD25300H 1/4 x 3 7288SD -- -- 3/4 x 8 1322 SDS 1/2" x 10" 8"<br />

7220SD THD37134H 3/8 x 1-3/4 7290SD THD75100H 3/4 x 10 1354 SDS-Max 1/2" x 13" 8"<br />

7222SD THD37212H 3/8 x 2-1/2 7726SD THD37400HMG 3/8 x 4 1394 HD Straight Shank 1/2" x 13" 11"<br />

7224SD THD37300H 3/8 x 3 7728SD THD37500HMG 3/8 x 5 1324 SDS 5/8" x 8" 6"<br />

7226SD THD37400H 3/8 x 4 7730SD THD37600HMG 3/8 x 6 1326 SDS 5/8" x 12" 10"<br />

7228SD THD37500H 3/8 x 5 7746SD THD50400HMG 1/2 x 4 1356 SDS-Max 5/8" x 13" 8"<br />

7230SD THD37600H 3/8 x 6 7748SD THD50500HMG 1/2 x 5 1396 HD Straight Shank 5/8" x 13" 11"<br />

7240SD THD50200H 1/2 x 2 7750SD THD50600HMG 1/2 x 6 1328 SDS 3/4" x 8" 6"<br />

Zinc<br />

7242SD THD50212H 1/2 x 2-1/2 7751SD THD50612HMG 1/2 x 6-1/2 1358 SDS-Max 3/4" x 13" 8"<br />

Plated<br />

7244SD THD50300H 1/2 x 3 7752SD THD50800HMG 1/2 x 8<br />

7246SD THD50400H 1/2 x 4 Mechanically<br />

THD62500HMG,<br />

7764SD 7248SD THD50500H 1/2 x 5 Galvanized<br />

THDB62500HMG<br />

5/8 x 5<br />

7250SD THD50600H 1/2 x 6 THD62612HMG,<br />

7766SD 7268SD THD50800H 1/2 x 6-1/2 THDB62600HMG<br />

5/8 x 6<br />

7252SD THDA62300H 1/2 x 8 7768SD THDB62612HMG 5/8 x 6-1/2<br />

7260SD THD62400H 5/8 x 3 THD62800HMG,<br />

7770SD 5/8 x 8<br />

7262SD THD62500H 5/8 x 4 THDB62800HMG<br />

7264SD THD62600H 5/8 x 5 7786SD -- -- 3/4 x 6<br />

Wedge-Bolt ® +<br />

7266SD THD50612H 5/8 x 6 7789SD THD75812HMG 3/4 x 8-1/2 (Zinc Plated)<br />

7270SD THD62800H 5/8 x 8 7790SD THD75100HMG 3/4 x 10<br />

7280SD -- -- 3/4 x 3<br />

1) The anchor size includes the diameter and length of the anchor measured from under the head.<br />

2) Wedge-Bolt®+ is marked with a blue tip and must be installed with a matched tolerance Wedge-Bit.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Wedge-Bit<br />

chor<br />

<strong>USP</strong><br />

Anchor <strong>USP</strong><br />

Usable<br />

1<br />

2<br />

Ref. No.<br />

1<br />

Stock No. Description Length<br />

x 1-1/4 7282SD THD75400H 3/4 x 4 1314 SDS 1/4" x 6" 4"<br />

x 1-3/4 7284SD THD75500H 3/4 x 5 1318 SDS 3/8" x 8" 6"<br />

Zinc<br />

x 2-1/4 7286SD THD75600H 3/4 x 6 1384 HD Straight Shank 3/8" x 13" 4"<br />

Plated<br />

4 x 3 7288SD -- -- 3/4 x 8 1322 SDS 1/2" x 10" 8"<br />

x 1-3/4 7290SD THD75100H 3/4 x 10 1354 SDS-Max 1/2" x 13" 8"<br />

x 2-1/2 7726SD THD37400HMG 3/8 x 4 1394 HD Straight Shank 1/2" x 13" 11"<br />

8 x 3 7728SD THD37500HMG 3/8 x 5 1324 SDS 5/8" x 8" 6"<br />

8 x 4 7730SD THD37600HMG 3/8 x 6 1326 SDS 5/8" x 12" 10"<br />

8 x 5 7746SD THD50400HMG 1/2 x 4 1356 SDS-Max 5/8" x 13" 8"<br />

8 x 6 7748SD THD50500HMG 1/2 x 5 1396 HD Straight Shank 5/8" x 13" 11"<br />

2 x 2 7750SD THD50600HMG 1/2 x 6 1328 SDS 3/4" x 8" 6"<br />

x 2-1/2 7751SD THD50612HMG 1/2 x 6-1/2 1358 SDS-Max 3/4" x 13" 8"<br />

2 x 3 7752SD THD50800HMG 1/2 x 8<br />

2 x 4 Mechanically<br />

THD62500HMG,<br />

7764SD<br />

Galvanized<br />

5/8 x 5<br />

2 x 6<br />

7766SD 5/8 x 6<br />

SDS-Max Wedge Bit<br />

SDS-Plus Wedge Bit<br />

MECHANICAL ANCHORS - POWER-STUD HD5 SERIES<br />

Wedge-Bolt ® +<br />

(Mechanically Galvanized)<br />

8 x 3<br />

The 7770SD Power-Stud HD5 5/8 x anchor 8 is a fully<br />

threaded, torque-controlled, wedge expansion<br />

anchor. Suitable base materials include normal-weight<br />

concrete and structural sand-lightweight<br />

concrete. The anchor is manufactured<br />

with a hot-dip galvanized carbon steel body<br />

and stainless steel expansion clip. Nut and<br />

washer are included.<br />

NEW<br />

<strong>USP</strong><br />

Stock No. 2 Ref. No.<br />

Anchor<br />

Size (in) 1<br />

Thread<br />

Length (in)<br />

7723HD5 WA50414MG 1/2 x 4-1/2 2-3/4<br />

7724HD5 WA50512MG 1/2 x 5-1/2 3-3/4<br />

7726HD5 WA50700MG 1/2 x 7 5-1/4<br />

7733HD5 -- -- 5/8 x 5 3<br />

7734HD5 WA62600MG 5/8 x 6 4<br />

7738HD5 -- -- 5/8 x 8-1/2 6-1/2<br />

1) The anchor size includes the diameter and<br />

the overall length of the anchor.<br />

2) All anchors are packaged with nuts and washers.<br />

Power-Stud HD5<br />

26<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Steel Angle Lintels – SAL series<br />

Steel Angle Lintels are used as support headers in door and window<br />

framing. For maximum allowable spans and minimum required bearing<br />

length check with applicable municipal, provincial or national building<br />

codes.<br />

Materials: 3 gauge<br />

Finish: Red primer<br />

W 1<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>USP</strong><br />

Stock No. Ref. No.<br />

Steel<br />

Gauge W1<br />

Dimensions (in)<br />

W2 L<br />

SAL36 -- -- 3 3-1/2 3-1/2 36<br />

SAL42 -- -- 3 3-1/2 3-1/2 42<br />

SAL48 -- -- 3 3-1/2 3-1/2 48<br />

SAL60 -- -- 3 3-1/2 3-1/2 60<br />

SAL72 -- -- 3 3-1/2 3-1/2 72<br />

SAL91 -- -- 3 3-1/2 3-1/2 91<br />

Welded Wire Mesh – WM series<br />

Welded wire adds strencth and stability to<br />

concrete foundations.<br />

Materials: 9 gauge carbon steel wire<br />

Finish: None<br />

W 2<br />

SAL<br />

L<br />

L<br />

Typical SAL<br />

installation<br />

Concrete & Masonry<br />

<strong>USP</strong><br />

Stock No.<br />

Steel Dimensions (in)<br />

Ref. No. Gauge W L<br />

WM48 -- -- 9 48 96<br />

WM60 -- -- 9 60 600<br />

Concrete Reinforcing Rod – CR series<br />

Concrete Reinforcing Rod provides added strength and stability for any<br />

concrete projects.<br />

Materials: Carbon steel conforms to A615 Steel<br />

Finish: None<br />

W<br />

WM<br />

Typical WM<br />

installation<br />

<strong>USP</strong><br />

Dimensions<br />

Stock No. Ref. No. D L<br />

CR12 -- -- 10 mm <br />

CR24 -- -- 10 mm <br />

CR36 -- -- 10 mm <br />

CR48 -- -- 10 mm <br />

CR72 -- -- 10 mm <br />

CR96 -- -- 10 mm <br />

L<br />

Tie Wire - TW series & TWTT<br />

TW – Tie Wire is used to secure concrete reinforcing rods in place<br />

during concrete forming.<br />

TWTT – Tie Wire Tying Tool.<br />

Materials: See chart<br />

Finish: TW1 – G90 galvanizing<br />

CR<br />

Typical CR<br />

installation<br />

<strong>USP</strong><br />

Stock No.<br />

Ref. No.<br />

Steel<br />

Gauge<br />

Length<br />

TW1 -- -- 18 6"<br />

TW3 -- -- 16 340'<br />

TW Typical TW<br />

TWTT Typical TWTT<br />

Installation<br />

Installation<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

27<br />

<strong>USP</strong>2240-131


Rod Chairs – RCD & RCT<br />

Rod chairs hold reinforcing bars for proper placement<br />

during the pouring or application of concrete.<br />

Materials: Welded Wire<br />

Finish: None<br />

RCD<br />

Typical RCD<br />

installation<br />

Concrete & Masonry<br />

<strong>USP</strong><br />

Stock No.<br />

Ref. No.<br />

Description<br />

Dimensions<br />

(in)<br />

RCD -- -- Double Rod Chair 4 x 5 x 8-1/4<br />

RCT -- -- Triple Rod Chair 3-1/2 x 4 x 12<br />

Safety Caps – SCV & SCH series<br />

Bright orange safety caps protect against injuries from vertical rebar.<br />

RCT<br />

Typical RCT<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: Composite Plastic<br />

Finish: None<br />

SCV<br />

Typical SCV<br />

installation<br />

<strong>USP</strong><br />

Stock No. Ref. No. Description Dimensions (in)<br />

SCH -- -- Horizontal Safety Cap 2-3/8 x 2-1/2 x 2-1/2<br />

SCV -- -- Vertical Safety Cap 3-1/4 x 3-3/4 x 3-3/4<br />

Anchor Bolt Stabber (Bolt Rite) – ABS12<br />

SCH<br />

Typical SCH<br />

installation<br />

For accurate placement of 1/2˝ (12.7 mm) anchor bolts in wet concrete. The<br />

outstanding legs are different lengths, with the shorter leg centering the anchor<br />

bolt in a 2 x 4 sill plate and the longer leg centering the anchor bolt in a 2 x 6<br />

sill plate.<br />

Materials: Composite Plastic<br />

Finish: See chart<br />

Patents: Pending<br />

Installation:<br />

• Slide ABS over anchor bolt and screw on cap.<br />

• Place bolt in wet concrete using guides for proper edge distance.<br />

<strong>USP</strong><br />

Bolt Dia.<br />

Stock No. 1<br />

Ref. No. (in) Color<br />

ABS12 -- -- 1/2 orange<br />

1) Anchor bolt caps are included with product.<br />

ABS12<br />

Typical ABS12<br />

installation<br />

28<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Threaded Rods – THR series<br />

<strong>USP</strong> has added longer length THR’s to support the new deck oriented<br />

code requirements for mechanically reinforced railing post and deck to<br />

house ledger board attachments.<br />

Materials: ASTM A 36 Steel, also conforms to ASTM F 1554 Grade 36<br />

Finish: Hot-dip galvanized<br />

L<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Installation:<br />

• Install into wet concrete or drill minimum 1 ⁄16" oversized hole and secure<br />

with anchor epoxy.<br />

• Nuts and washers are included.<br />

<strong>USP</strong><br />

Stock No. Ref. No.<br />

Bolt Dia.<br />

(in)<br />

L<br />

(in)<br />

THR125-HDG RFB#4X5HDG 1/2 5<br />

THR126-HDG RFB#4X6HDG 1/2 6<br />

THR128-HDG RFB#4X8HDG 1/2 8<br />

THR1218-HDG -- -- 1/2 18<br />

THR1224-HDG -- -- 1/2 24<br />

THR1236-HDG -- -- 1/2 36<br />

THR585-HDG RFB#5X5HDG 5/8 5<br />

THR588-HDG RFB#5X8HDG 5/8 8<br />

THR5812-HDG RFB#5X12HDG 5/8 12<br />

THR5816-HDG RFB#5X16HDG 5/8 16<br />

New products or updated product<br />

information are designated in red font.<br />

NEW<br />

SIZES<br />

Epoxy Coated Rebar – CRE24<br />

THR<br />

½" THR<br />

Threaded<br />

Rod<br />

Typical THR<br />

installation<br />

DTB-TZ<br />

Page 195<br />

Typical THR<br />

Deck to ledger installation<br />

Concrete & Masonry<br />

Two-foot epoxy coated rebar provides maximum protection<br />

against corrosion.<br />

Materials: A615 Steel<br />

Finish: Epoxy Dipped<br />

<strong>USP</strong><br />

Dimensions<br />

Stock No. Ref. No. Dia L<br />

CRE24 -- -- 10 mm 24"<br />

Round Nail Stake – NSR<br />

Nail stakes are used to secure form boards to prevent movement and<br />

bowing.<br />

Materials: Steel<br />

Finish: Black Primer<br />

Installation:<br />

• Fastener holes will accommodate up to a 16d duplex nail.<br />

<strong>USP</strong><br />

Dimensions (in)<br />

Stock No. Ref. No. Dia L<br />

NSR -- -- 3/4 18<br />

Retro Plate – RP6<br />

Uses heavy gauge HRPO steel and a large surface<br />

area to distribute seismic forces on masonry exteriors.<br />

L<br />

CRE24<br />

NSR<br />

Typical CRE24<br />

installation<br />

Typical NSR<br />

installation<br />

Materials: 3/8˝ plate<br />

Finish: <strong>USP</strong> primer<br />

Options: RP6 is available in Hot-dip<br />

galvanized. To order add HDG to<br />

stock number, as in RP6-HDG.<br />

6˝<br />

3˝<br />

3/4˝ dia.<br />

threaded rod<br />

Installation:<br />

• Install with a 3/4˝ diameter steel threaded rod.<br />

<strong>USP</strong><br />

Stock No. Ref. No.<br />

RP6 RP6<br />

3˝<br />

6˝<br />

RP6<br />

Typical RP6<br />

installation<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

29<br />

<strong>USP</strong>2240-131


Concrete Form Ties & Wedge – FT series & WG<br />

FT – Connect 1x and 2x nominal form lumber in low foundation<br />

walls up to 4 feet high.<br />

11/16˝<br />

WG – V-shaped wedge assures rigidity<br />

and consistent form spacing.<br />

Materials: FT – 18 gauge, WG – 14 gauge<br />

Finish: G90 galvanizing<br />

3 5 /8˝<br />

Concrete & Masonry<br />

Installation:<br />

• Use the Spacing Guide chart to determine spacing between<br />

FT units. Each level in chart assumes 12˝ form boards. Wall<br />

thickness from 6˝ to 12˝.<br />

• Install with “V” facing up.<br />

• Use (2) WG wedges for each tie. Insert wedge into inside slots<br />

for 1x nominal forms and outside slots for 2x nominal forms.<br />

• No walers or stiff-backs are used.<br />

• Vertical ties to keep forms from separating are not included.<br />

• Form deflection may be substantial. Check deflection, if it is<br />

critical, and move ties to compensate.<br />

• Forming lumber is assumed to have fb of 1,000 psi.<br />

• Not recommended for pours greater than 4 feet in height.<br />

3/16˝<br />

WG Wedge<br />

must order<br />

separately<br />

L<br />

FT<br />

W<br />

Typical FT/WG<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Spacing Guide chart<br />

<strong>USP</strong><br />

Steel<br />

Dimensions (in) Wedge<br />

Footing Width<br />

Stock No. Ref. No. Gauge W L Qty Type or Wall Thickness<br />

FT6 WT6 18 5/8 10-5/8 2 WG 6<br />

FT8 WT8 18 5/8 12-5/8 2 WG 8<br />

FT10 WT10 18 5/8 14-5/8 2 WG 10<br />

FT12 WT12 18 5/8 16-5/8 2 WG 12<br />

WG W1 14 11/16 3-5/8 -- -- -- -- -- --<br />

<br />

<br />

<br />

Concrete Level 1 Level 2 Level 3 Level 4<br />

Lift Height 1x 2x 1x 2x 1x 2x 1x 2x<br />

-- -- -- -- -- -- -- -- -- -- -- --<br />

-- -- -- -- -- -- -- --<br />

-- -- -- --<br />

<br />

<br />

Kwik Strip Ties – RKS200<br />

For foundation applications where rental forms are<br />

used. Ease of form wall erection and removal makes<br />

this system very practical and economical. Use Kwik<br />

Strip Ties to hold form walls parallel, to prevent bulging<br />

and to prevent them from collapsing while concrete is<br />

being poured. 2 x 4 studding is not required for form<br />

work.<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

<strong>USP</strong><br />

Steel Dimensions Footing Width or<br />

Stock<br />

Ref. No. Gauge W L Wall Tickness<br />

No.<br />

RKS200 -- -- 18 3/4 12-1/8 approximates 8"<br />

RKS<br />

Water<br />

bar<br />

installed<br />

Stake every<br />

2 feet<br />

1 x 3 cleat<br />

every 2 feet<br />

Typical RKS<br />

installation<br />

Kwik Strip Ties<br />

installed<br />

30<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Anchor Bolts – STB & STBL series<br />

Embossed ends provide guides for embedment angle and depth. An embedment line is<br />

embossed on the shaft for easy installation. Features rolled threads for high tensile strength.<br />

STB – For monolithic slabs and concrete stem walls.<br />

STBL – Designed for use with 3x sill plates. Excellent choice for<br />

use with taller holdown washers like those in the PHD/PHDA<br />

series.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: ASTM F 1554 Grade 36<br />

Finish: None<br />

Options: STB16, STB20, STB24, STB28, STB34,<br />

STBL24, and STBL28 models are available in<br />

Hot-dip galvanized. To order, add HDG to end of<br />

stock number, as in STB34-HDG.<br />

Codes: Load values are derived from data submitted to<br />

various North American building code<br />

evaluators.<br />

Installation:<br />

• Select appropriate STB or STBL Anchor Bolt.<br />

• Use normal weight concrete with minimum compressive strength of 2,500 psi.<br />

• Minimum centre-to-centre spacing between bolts is 3(E) for anchors acting<br />

simultaneously in tension.<br />

• Match embedment depth with embedment line on the STB or STBL shaft.<br />

• The STB or STBL does not need to be tied to the rebar.<br />

• Nuts and washers are not included.<br />

• Use <strong>USP</strong>’s ABS12 anchor bolt stabber to hold anchor bolt in place during installation.<br />

Typical STB Anchor<br />

Bolt installation<br />

(No. 4 Rebar in Breakout Zone,<br />

Min. 1-3/4” Edge Distance)<br />

Concrete & Masonry<br />

Monolithic or Stem Wall Foundations – Prior to pour, install the STB or STBL in an upright<br />

position and at a 45° angle to the wall. Install one horizontal #4 rebar at a depth of 4˝ (minimum).<br />

(See illustrations.)<br />

Concrete Block Applications – Prior to cell pour, install the STB or STBL in an upright<br />

position and at a 45° angle to the wall. (See illustrations.) Use the embossed angle guide<br />

on the end of the STB or STBL shaft as a guide. Install one horizontal #4 rebar at a depth<br />

of 4˝ and one vertical #4 rebar maximum 48˝ o.c. spacing. Fill all cells with concrete having<br />

a minimum 2,000 psi compressive strength.<br />

STB Anchor Bolt<br />

Installation – Along<br />

Continuous Stem Wall<br />

(No.4 Rebar Min Length = 4xl e ,<br />

Min. 1-3/4" Edge Distance)<br />

STB Anchor Bolt<br />

Installation – Corner<br />

of Stem Wall<br />

(Min. 12" Return Stem Wall,<br />

Min. 5" End Distance)<br />

STB Anchor Bolt<br />

Installation – End of<br />

Stem Wall<br />

(Min. 5" End Distance, and<br />

No.4 Rebar Min Length)<br />

STB Anchor Bolt<br />

(Identification on bolt head,<br />

minimum anchor embedment, l e )<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

31<br />

<strong>USP</strong>2240-131


Anchor Bolts – STB & STBL series continued<br />

Concrete & Masonry<br />

Anchor Bolt Selection table<br />

2x, 3x, (2) 2x<br />

Sill Plates 1<br />

<strong>USP</strong><br />

Stock No.<br />

Mono Pour<br />

PHD2A<br />

TDX2-TZ<br />

LTS20B<br />

STB16<br />

HTT45<br />

STBL16<br />

HTT4<br />

HTT16<br />

PHD4A<br />

STB20<br />

HTT45<br />

STBL20<br />

HTT45<br />

STB24<br />

HTT5<br />

STBL24<br />

PHD8<br />

UPHD8<br />

STB28<br />

TD7<br />

STBL28<br />

TD9<br />

TD12<br />

* Recommend installation of<br />

washer under nut of anchor bolt.<br />

1) STBL model are recommended<br />

for use with PHD and UPHD8<br />

holdowns on (2) 2x and 3x<br />

sill plates.<br />

Typical STB/STBL<br />

concrete block installation<br />

Corner<br />

installation<br />

Non-Corner<br />

installation<br />

Corner<br />

installation<br />

Plan view of STB/STBL<br />

placement in concrete stemwall<br />

0˚<br />

Outside edge<br />

of concrete<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>USP</strong><br />

Stock No.<br />

STB16<br />

STB20<br />

STB24<br />

STB28<br />

STB34<br />

STB36<br />

STBL16<br />

STBL20<br />

STBL24<br />

STBL28<br />

Dimensions (in)<br />

Stemwall<br />

Min.<br />

Seismic I e F a S a (0.2) < 0.35 Wind I e F a S a (0.2) < 0.35 Seismic I e F a S a <br />

Ref. No. Width Dia. L H Embed. (E) Unit Midwall Corner End Wall Midwall Corner End Wall Midwall Corner End Wall<br />

SSTB16<br />

SSTB20<br />

SSTB24<br />

SSTB28<br />

SSTB34<br />

SSTB36<br />

SSTBL16<br />

SSTBL20<br />

SSTBL24<br />

SSTBL28<br />

6<br />

6<br />

6<br />

8<br />

8<br />

8<br />

6<br />

6<br />

6<br />

8<br />

5/8<br />

5/8<br />

5/8<br />

7/8<br />

7/8<br />

7/8<br />

5/8<br />

5/8<br />

5/8<br />

7/8<br />

17-13/16<br />

21-13/16<br />

25-13/16<br />

31<br />

36<br />

38<br />

19-9/16<br />

23-9/16<br />

27-9/16<br />

32-3/4<br />

5<br />

5<br />

5<br />

5<br />

6<br />

8<br />

6-3/4<br />

6-3/4<br />

6-3/4<br />

6-3/4<br />

12-13/16<br />

16-13/16<br />

20-13/16<br />

26<br />

30<br />

30<br />

12-13/16<br />

16-13/16<br />

20-13/16<br />

26<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

5920<br />

7170<br />

8385<br />

14140<br />

15980<br />

15980<br />

5920<br />

7170<br />

8385<br />

14140<br />

5920<br />

6635<br />

8280<br />

13285<br />

14735<br />

14735<br />

5920<br />

6635<br />

8280<br />

13285<br />

5920<br />

6635<br />

8280<br />

13285<br />

14350<br />

14350<br />

5920<br />

6635<br />

8280<br />

13285<br />

6770<br />

8185<br />

9585<br />

14575<br />

18225<br />

18225<br />

6770<br />

8185<br />

9585<br />

14575<br />

6770<br />

6770<br />

8910<br />

14575<br />

16840<br />

16840<br />

6770<br />

6770<br />

8910<br />

14575<br />

6770<br />

6770<br />

8910<br />

14575<br />

15050<br />

15050<br />

6770<br />

6770<br />

8910<br />

14575<br />

4935<br />

5970<br />

6985<br />

10710<br />

13320<br />

13320<br />

4935<br />

5970<br />

6985<br />

10710<br />

4935<br />

4975<br />

6545<br />

10710<br />

12280<br />

12280<br />

4935<br />

4975<br />

6545<br />

10710<br />

4935<br />

4975<br />

6545<br />

10710<br />

11060<br />

11060<br />

4935<br />

4975<br />

6545<br />

10710<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

26.33<br />

31.90<br />

37.30<br />

62.90<br />

71.09<br />

71.09<br />

26.33<br />

31.90<br />

37.30<br />

62.90<br />

26.33<br />

29.52<br />

36.83<br />

59.10<br />

65.55<br />

65.55<br />

26.33<br />

29.52<br />

36.83<br />

59.10<br />

26.33<br />

29.52<br />

36.83<br />

59.10<br />

63.83<br />

63.83<br />

26.33<br />

29.52<br />

36.83<br />

59.10<br />

30.12<br />

36.41<br />

42.64<br />

64.84<br />

81.07<br />

81.07<br />

30.12<br />

36.41<br />

42.64<br />

64.84<br />

30.12<br />

30.12<br />

39.64<br />

64.84<br />

74.91<br />

74.91<br />

30.12<br />

30.12<br />

39.64<br />

64.84<br />

30.12<br />

30.12<br />

39.64<br />

64.84<br />

66.95<br />

66.95<br />

30.12<br />

30.12<br />

39.64<br />

64.84<br />

21.95<br />

26.56<br />

31.07<br />

47.64<br />

59.25<br />

59.25<br />

21.95<br />

26.56<br />

31.07<br />

47.64<br />

21.95<br />

22.13<br />

29.11<br />

47.64<br />

54.63<br />

54.63<br />

21.95<br />

22.13<br />

29.11<br />

47.64<br />

21.95<br />

22.13<br />

29.11<br />

47.64<br />

49.20<br />

49.20<br />

21.95<br />

22.13<br />

29.11<br />

47.64<br />

1) Loads may not be increased for short term loading.<br />

2) Minimum center to center spacing between bolts is 3(E) for anchors acting in tension simultaneously.<br />

<br />

<br />

<br />

6) Connection is limited by lowest of bolt or holdown capacity.<br />

<br />

New products or updated product information are designated in red font.<br />

Factored Tensile Resistance 1,2<br />

32<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Anchor Bolts – AB & ABP series<br />

Anchor Bolts are used to secure wood plates to foundation walls. Washers are<br />

available in various package combinations.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: Bolt: ASTM F 844, Nut: ASTM A 563, Washers: ASTM F 844<br />

Finish: AB126-HDG, AB128-HDG, AB1212-HDG, AB5812-HDG –<br />

Hot-dip galvanized; All others – none<br />

Installation:<br />

• Select appropriate AB or ABP Anchor Bolt.<br />

• Use concrete with minimum compressive strength of<br />

2,000 psi at 28 days<br />

• Nuts and standard washers are included.<br />

• Anchor bolts intended for use to satisfy code<br />

prescribed anchoring of mudsill plates, and shall be<br />

installed as defined in the code.<br />

• Factored resistance shall be derived in accordance<br />

with the code.<br />

<strong>USP</strong><br />

Stock No. Ref. No.<br />

Bolt<br />

Dia. (in)<br />

L<br />

(in)<br />

AB126-HDG -- -- 1/2 6<br />

AB128-HDG -- -- 1/2 8<br />

AB1212-HDG -- -- 1/2 12<br />

AB5812-HDG -- -- 5/8 12<br />

AB6NW -- -- 1/2 6<br />

AB8NW -- -- 1/2 8<br />

ABP6NW -- -- 1/2 6<br />

ABP8NW -- -- 1/2 8<br />

L<br />

ABP<br />

Typical AB<br />

installation<br />

AB<br />

L<br />

Concrete & Masonry<br />

Foundation Anchors – SFA & SFJA series<br />

SFA – Mudsill anchors for retrofit applications. Features a<br />

slotted bend line for easy field adjustment when foundation walls<br />

are slanted.<br />

SFJA – Ties floor joists directly to foundations with bolt fastening.<br />

Materials: 12 gauge<br />

Finish: G90 galvanizing<br />

7˝<br />

F1<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page<br />

10.<br />

• A design professional must specify anchor bolt type, length,<br />

and embedment. Anchor bolts are laterally loaded. Follow<br />

installation instructions for epoxy adhesive.<br />

• Factored resistance assume a minimum concrete compressive<br />

strength of 2,000 psi.<br />

8˝<br />

SFA8<br />

6˝<br />

Typical SFA installation<br />

Fastener Schedule<br />

Factored Resistance 1<br />

Anchor<br />

Framing<br />

DF-L<br />

S-P-F<br />

<strong>USP</strong><br />

Steel<br />

Bolts<br />

Nails 2,4 Bolts 3 F1 Uplift F1 Uplift<br />

Stock No. Ref. No. Gauge Qty Dia. Qty Type Qty Dia. 115% 115% 115% 115%<br />

SFJA FJA 12 1 5/8 -- -- -- -- 2 5/8 -- -- 1620 -- -- 1360<br />

SFA8 -- -- 12 2 1/2 7 10d x 1-1/2 -- -- -- -- 1085 -- -- 915 -- --<br />

1) The 115% values are short-term loads such as wind and earthquake.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) Bolts shall conform to ASTM A 307 or better.<br />

4) NAILS:<br />

red font.<br />

Uplift<br />

1 1 /2˝<br />

6˝<br />

6 1 /2˝<br />

Typical SFJA<br />

installation<br />

1 1 /2˝<br />

SFJA<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

33<br />

<strong>USP</strong>2240-131


Foundation Anchors – FA3 series<br />

Concrete & Masonry<br />

For installation into concrete slabs. The FA3 features a split flange for nailing<br />

to both mudsill and stud for greater framing versatility.<br />

Materials: 16 gauge<br />

Finish: G90 galvanizing<br />

Options: FA3 is available in Triple Zinc.<br />

To order, add TZ to end of stock number,<br />

as in FA3-TZ.<br />

Codes: Load values are derived from data submitted to<br />

various North American building code<br />

evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Use a minimum of two anchors per mudsill. An anchor should always be<br />

within 12˝ of the end of each mudsill section.<br />

• Do not rely on these anchors to secure concrete sections together between<br />

cold joints.<br />

• Insert into wet concrete (minimum strength of 2,000 psi). Place mudsill after<br />

concrete cures. Secure flanges to sill (and stud, if applicable), bending flanges<br />

as needed to achieve a tight fit. Fasten as directed in chart.<br />

1 1 /2˝<br />

4 5 /8˝<br />

F2<br />

5 3 /4˝<br />

FA3<br />

F1<br />

Embossed lines<br />

provide guide for<br />

matching to edge<br />

of form board<br />

1˝<br />

Uplift<br />

Typical FA3 installation<br />

in concrete<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

FA3 Form board<br />

installation<br />

Alternate FA3<br />

installation<br />

Typical FA3 installation<br />

to mudsill and stud<br />

Plate<br />

Size<br />

2 x4<br />

or<br />

2 x 6<br />

2 x4<br />

or<br />

2 x 6<br />

Dimensions (in)<br />

Fastener Schedule 1,9 DF-L Factored Resistance 2,3,5,6,7<br />

S-P-F Factored Resistance 2,3,5,6,7<br />

Sill Plate<br />

Stud Min Wind and SDC A & B SDC C-F Wind and SDC A & B SDC C-F<br />

Stemwall<br />

Side Top Uplift F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift F1 F2<br />

<strong>USP</strong> Ref. Steel<br />

Thickness<br />

Stock No No. Ga. W L I E D Qty Qty Type Qty Type (in.) Unit 115% 115% 115% 115% 115% 115% 115% 115% 115% 115% 115% 115%<br />

Uncracked Concrete 8<br />

FA3<br />

Lbs 1045 645 760 1045 645 760 900 555 655 900 555 655 1010 62<br />

2 4 10d x 1-1/2 -- -- -- -- 6<br />

Mudsill Only MAS<br />

kN 4.65 2.87 3.38 4.65 2.87 3.38 4.00 2.47 2.91 4.00 2.47 2.91<br />

16 1-1/2 4-5/8 4 1<br />

FA3<br />

Lbs 780 635 480 780 635 480 670 545 415 670 545 415 755 61<br />

2 2 10d x 1-1/2 2 10d x 1-1/2 6<br />

Mudsill & Stud<br />

kN 3.47 2.82 2.14 3.47 2.82 2.14 2.98 2.42 1.85 2.98 2.42 1.85<br />

Cracked Concrete 8<br />

FA3<br />

Lbs 1020 565 760 875 485 670 875 485 655 755 415 575 985 54<br />

2 4 10d x 1-1/2 -- -- -- -- 6<br />

Mudsill Only MAS<br />

kN 4.54 2.51 3.38 3.89 2.16 2.98 3.89 2.16 2.91 3.36 1.85 2.56<br />

16 1-1/2 4-5/8 4 1<br />

FA3<br />

Lbs 780 565 480 780 485 480 670 485 415 670 415 415 755 54<br />

2 2 10d x 1-1/2 2 10d x 1-1/2 6<br />

Mudsill & Stud<br />

kN 3.47 2.51 2.14 3.47 2.16 2.14 2.98 2.16 1.85 2.98 1.85 1.85<br />

1) Predrilled holes are not required.<br />

2) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increased is allowed.<br />

3) FA3 capacities are based on using a single-ply 2x sill plate.<br />

4) Minimum distance of 1.5 x I E ( 6 inches) is required to obtain the listed capacity.<br />

5) Minimum anchor spacing for full capacity is 2 x l E . For spacing less than that reduce capacity proportionally.<br />

6) Factored resistances are based on lumber with a specific gravity of 0.49 and a moisture content of 19% or less.<br />

7) Uplift deformation based on wood connection strength.<br />

8) Minimum concrete strength f'c = 2500 psi<br />

9) Minimum nail embedment shall be 8 nail diameters (typ).<br />

10) NAILS:<br />

New products or updated product information are designated in red font.<br />

34<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Foundation Anchors – ST series<br />

ST1-TZ – For installation into concrete slab or poured stemwalls.<br />

The ST1-TZ features a prebent base flange to assure proper<br />

anchoring into concrete.<br />

ST2-TZ – For installation into concrete slab, poured stemwalls or<br />

concrete/masonry. The ST2-TZ features a prebent base flange to assure<br />

proper anchoring into concrete. Do not use in red clay brick.<br />

Min. embed<br />

8 1/2" E<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: 18 gauge<br />

Finish: G-185 galvanizing<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Use a minimum of two anchors per mudsill. An anchor should always be<br />

within 12˝ of the end of each mudsill section.<br />

• Do not rely on these anchors to secure concrete sections together between<br />

cold joints.<br />

• Spread sill flanges to mudsill width prior to insertion into wet concrete<br />

(minimum strength of 2,000 psi or 13.8 MPa). Alternate installation is<br />

possible by inserting unbent flanges through 3/4˝ center hole predrilled in<br />

mudsill. Foundation anchors may also be attached to mudsill and then<br />

inserted into wet concrete. When installing ST2-TZ into concrete block, fill cells<br />

with grout with a minimum strength of 2,000 psi or 13.8 MPa. Concrete block<br />

edges may need to be beveled to facilitate installation.<br />

• ST2-TZ in masonry construction shall be installed in the core of the block and<br />

grouted with concrete grout designed for that purpose. In no case, shall they<br />

be installed in a mortar joint.<br />

Typical<br />

ST1-TZ<br />

installation<br />

in concrete<br />

Uplift<br />

F 1<br />

F 2<br />

Alternate<br />

ST1-TZ<br />

installation with<br />

3/4˝center hole<br />

Drill 3 ⁄4" dia.<br />

hole<br />

Drill 3 ⁄4" dia.<br />

hole<br />

Concrete & Masonry<br />

Spread sill flanges to sill<br />

width prior to insertion<br />

into wet concrete<br />

10˝<br />

18˝<br />

DO NOT install<br />

ST1-TZ and ST2-TZ<br />

without pre-bending<br />

sill flanges in “Y”<br />

configuration<br />

ST1-TZ<br />

ST2-TZ<br />

Alternate<br />

ST2-TZ<br />

installation with<br />

3/4˝ center hole<br />

in mudsill<br />

Plate<br />

Size<br />

2 x 4 - 6<br />

<strong>USP</strong><br />

Stock No.<br />

ST1-TZ<br />

ST2-TZ<br />

Fastener Schedule 2,3<br />

Min.<br />

Factored Resistance (115%) 1<br />

Steel Mudsill Top Mudsill Side Embed. (in)<br />

DF-L<br />

S-P-F<br />

Ref. No. Gauge Qty Type Qty Type<br />

(E)<br />

Unit F1 F2 Uplift F1 F2 Uplift<br />

MAB15,<br />

Lbs 979 1134 1310 839 972 1123<br />

18 4 8d x 1-1/2 HDG 4 8d x 1-1/2 HDG <br />

MAB15Z<br />

kN 4.36 5.04 5.83 3.73 4.32 4.99<br />

MAB23,<br />

Lbs 979 1134 1310 839 972 1123<br />

18 4 8d x 1-1/2 HDG 4 8d x 1-1/2 HDG <br />

MAB23Z<br />

kN 4.36 5.04 5.83 3.73 4.32 4.99<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase is allowed.<br />

For standard term loads divide the values by 1.15.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS<br />

red font.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

35<br />

<strong>USP</strong>2240-131


Laminated Beam Seats – KGLB, KGLBT, & KHGLB series<br />

Concrete & Masonry<br />

KGLB – Single bolt, bearing only.<br />

KGLBT – Double bolt with Structural Tee provides uplift and horizontal resistance.<br />

KHGLB – Double bolt design provides uplift and horizontal resistance.<br />

Materials: Flanges – 1/4˝ steel<br />

Bearing Plate – See chart<br />

Anchor dowels – 3⁄4˝ x 12˝ rebar<br />

Finish: <strong>USP</strong> primer<br />

Options: Consult <strong>USP</strong> for non-catalogue variations.<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product<br />

Notes, page 10.<br />

• Bolt holes shall be a minimum of 1⁄ 32˝ to a<br />

maximum of 1⁄ 16˝ larger than the bolt diameter.<br />

• Concrete or masonry walls must be checked<br />

by a design professional for adequacy to resist<br />

lateral or uplift loads transferred from the beam<br />

seat anchor.<br />

<strong>USP</strong><br />

Stock<br />

No.<br />

Dimensions (in) Bolt Schedule Factored Bearing Resistance 1,4,5<br />

Masonry @ 375 psi 2 Concrete 3<br />

Dia.<br />

Ref. No. W L T D Qty<br />

(in)<br />

Lbs kN Lbs kN<br />

KGLB5A GLB5A 5-1/4 7 1/4 5 1 5/8 16980 75.53 16980 75.53<br />

KGLB5B GLB5B 5-1/4 7 3/8 6 1 5/8 20370 90.61 20370 90.61<br />

KGLB5C GLB5C 5-1/4 7 3/8 7 1 5/8 23765 105.72 23765 105.72<br />

KGLB5D GLB5D 5-1/4 7 3/8 8 1 5/8 27160 120.82 27160 120.82<br />

KGLB7A GLB7A 6-7/8 9 1/4 5 1 3/4 22355 99.44 22355 99.44<br />

KGLB7B GLB7B 6-7/8 9 3/8 6 1 3/4 26825 119.33 26825 119.33<br />

KGLB7C GLB7C 6-7/8 9 3/8 7 1 3/4 31300 139.23 31300 139.23<br />

KGLB7D GLB7D 6-7/8 9 3/8 8 1 3/4 35770 159.12 35770 159.12<br />

1) Beams must fully bear on plates.<br />

2) Factored bearing resistances are based on the bearing value listed times the bearing area equal to W x D. (Note that full<br />

bearing plate area is not used.) Factored bearing resistances shall be reduced where limited by wood bearing on the plate.<br />

3) Factored bearing resistances on concrete are based on factored wood bearing stress perpendicular to the grain of 460 psi<br />

and actual beam width times beam bearing length.<br />

4) Designer shall specify minimum edge and spacing requirements in masonry or concrete structure.<br />

5) Concrete or masonry support structure is assumed adequate to support loads listed.<br />

<strong>USP</strong><br />

Stock No.<br />

KHGLBA<br />

KHGLBB<br />

KHGLBC<br />

KHGLBD<br />

KGLBT512<br />

KGLBT612<br />

KGLBT516<br />

KGLBT616<br />

KGLBT520<br />

KGLBT620<br />

T<br />

L<br />

3˝<br />

3 1 /2˝<br />

KGLB<br />

W<br />

D<br />

12˝<br />

Bearing Plate<br />

Concrete pilaster<br />

Rebar welded to<br />

bearing plate<br />

Dimensions (in)<br />

Bolt<br />

Factored Bearing Resistance 1,5<br />

Schedule<br />

Masonry On Concrete with Beam Width 1 F2 3,4 Min. 3-1/8<br />

Range<br />

Dia.<br />

@<br />

Beam Width (W)<br />

Ref. No. W D L T Qty (in) Unit 375 psi 5-1/8 6-3/4 8-3/4 10-3/4 100% Uplift 115% 3<br />

HGLBA<br />

HGLBB<br />

HGLBC<br />

HGLBD<br />

GLBT512<br />

GLBT612<br />

GLBT516<br />

GLBT616<br />

GLBT520<br />

GLBT620<br />

3-1/4 to 9<br />

3-1/4 to 9<br />

3-1/4 to 9<br />

3-1/4 to 9<br />

3-1/4 to 11<br />

3-1/4 to 11<br />

3-1/4 to 15<br />

3-1/4 to 15<br />

3-1/4 to 19<br />

3-1/4 to 19<br />

5<br />

6<br />

7<br />

8<br />

5-1/2<br />

6-1/2<br />

5-1/2<br />

6-1/2<br />

5-1/2<br />

6-1/2<br />

10<br />

10<br />

10<br />

10<br />

12<br />

12<br />

16<br />

16<br />

20<br />

20<br />

3/8<br />

3/8<br />

3/8<br />

3/8<br />

1/3<br />

3/8<br />

1/3<br />

3/8<br />

1/3<br />

3/8<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

3/4<br />

3/4<br />

3/4<br />

3/4<br />

3/4<br />

3/4<br />

3/4<br />

3/4<br />

3/4<br />

3/4<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

27000<br />

32400<br />

37800<br />

43200<br />

35640<br />

42120<br />

39170<br />

46290<br />

39170<br />

46290<br />

16980<br />

20370<br />

23765<br />

27160<br />

18670<br />

22070<br />

18670<br />

22070<br />

18670<br />

22070<br />

22355<br />

26825<br />

31300<br />

35770<br />

24595<br />

29065<br />

24595<br />

29065<br />

24595<br />

29065<br />

28980<br />

34775<br />

40570<br />

46370<br />

31880<br />

37680<br />

31880<br />

37680<br />

31880<br />

37680<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

39170<br />

46290<br />

39170<br />

46290<br />

39170<br />

46290<br />

9445<br />

9445<br />

9445<br />

9445<br />

9445<br />

9445<br />

9445<br />

9445<br />

9445<br />

9445<br />

4045<br />

4045<br />

4045<br />

4045<br />

4045<br />

4045<br />

4045<br />

4045<br />

4045<br />

4045<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

120.11<br />

144.13<br />

168.15<br />

192.17<br />

158.54<br />

187.37<br />

174.24<br />

205.92<br />

174.24<br />

205.92<br />

75.53<br />

90.61<br />

105.72<br />

120.82<br />

83.05<br />

98.18<br />

83.05<br />

98.18<br />

83.05<br />

98.18<br />

99.44<br />

119.33<br />

139.23<br />

159.12<br />

109.41<br />

129.29<br />

109.41<br />

129.29<br />

109.41<br />

129.29<br />

128.91<br />

154.69<br />

180.47<br />

206.27<br />

141.81<br />

167.62<br />

141.81<br />

167.62<br />

141.81<br />

167.62<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

174.24<br />

205.92<br />

174.24<br />

205.92<br />

174.24<br />

205.92<br />

42.02<br />

42.02<br />

42.02<br />

42.02<br />

42.02<br />

42.02<br />

42.02<br />

42.02<br />

42.02<br />

42.02<br />

17.99<br />

17.99<br />

17.99<br />

17.99<br />

17.99<br />

17.99<br />

17.99<br />

17.99<br />

17.99<br />

17.99<br />

1) Beams must fully bear on plates.<br />

2) Factored bearing resistances on concrete are based on factored bearing stress perpendicular to the grain of 460 psi and<br />

actual beam width times beam bearing length.<br />

3) The 115% values are short-term loads such as wind and earthquake and are based on bolt in wood values only.<br />

Factored resistances assume concrete or masonry structure is adequate to resist loads in those directions.<br />

4) Factored resistances must be be reduced if the allowable lateral load (F2) for masonry or concrete column governs.<br />

5) Designer shall specify minimum edge and spacing requirements in masonry or concrete structure.<br />

1/2˝ Min.<br />

clearance<br />

Uplift<br />

F2<br />

Typical KGLB installation<br />

D<br />

L<br />

3˝<br />

L<br />

3 1 /2˝<br />

1 1 /2˝<br />

3˝<br />

2 1 /2˝<br />

1 1 /2˝<br />

W<br />

Structural<br />

tee<br />

KGLBT<br />

W<br />

2 1 /2˝<br />

KHGLB<br />

1 1 /4˝<br />

T<br />

1 1 /4˝<br />

D<br />

T<br />

3˝<br />

4˝ 12˝<br />

3˝<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

36<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Adjustable Support Posts – JP series<br />

Adjustable Support Posts may be used to support carport roofs and beams<br />

carrying loads not more than two wood frame floors, where the length of joists<br />

carried by such beams does not exceed 16’ and a live load on any floor does not<br />

exceed 50 lbs/ft 2 .<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: 3 gauge steel plates (3.5˝ x 6˝);<br />

12 gauge outer tube (2 3⁄4˝ O.D);<br />

11 gauge inner tube (2 1⁄2˝ O.D.)<br />

Finish: RSC Red Primer Paint<br />

Codes: JP108: CCMC 09199-L<br />

Conform to NBC 2010, Article 9.17.3.4.(1) and to<br />

CAN/CGSB-7.2-94.<br />

Installation:<br />

• Elevate top tubing to approximate height and insert locking pin. Rotate jack screw<br />

to desired height, then fasten top plate in position. Ensure top and bottom plates are<br />

properly fastened to supported beam members and properly aligned to the<br />

supported base footing. Always ensure product is installed 90º to beam and footing.<br />

<strong>USP</strong><br />

Steel<br />

Adjustable Height Allowable Load 1,2 Factored Resistance 1,2<br />

Stock No. Ref. No. Gauge in mm Lbs kN Lbs kN<br />

JP24 -- -- 3 17 - 24 432 - 610 8555 38.06 12319 54.80<br />

JP60 -- -- 3 36 - 60 914 - 1524 8555 38.06 12319 54.80<br />

JP96 -- -- 3 60 - 96 1524 - 2438 8555 38.06 12319 54.80<br />

JP108 -- -- 3 72 - 108 1829 - 2743 8177 36.37 11775 52.38<br />

1) The loads given above the established in accordance with CAN/CGSB-7-2 for allowable<br />

load design. The factored resistances given above are for Limit States Design in<br />

accordance with the 1995 National Building Code of Canada.<br />

2) The bearing resistance of the supported beam should be checked by the building designer<br />

using the appropriate CSA standard.<br />

JP<br />

Concrete & Masonry<br />

Replacement Parts for<br />

Adjustable Support Posts<br />

<strong>USP</strong><br />

Stock No.<br />

Qty/<br />

Package<br />

Description<br />

JPCP Setting Pin 1<br />

JPSN Screw & Nut Assembly 1<br />

JPSP 6" x 7" Steel Plate 15<br />

JPSSN Screw & Nut Assembly 1<br />

JPTP Top Plate 1<br />

Typical JP<br />

installation<br />

JPSP<br />

JPSN<br />

JPSSN<br />

JPTP<br />

JPCP<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

37<br />

<strong>USP</strong>2240-131


Adjustable Support Posts – Type 2 series<br />

Concrete & Masonry<br />

Meets or exceeds CCMC requirements for a Type 2 Adjustable Steel Column and<br />

may be used to support carport roofs and beams carrying not more than two woodframe<br />

floors where the length of the joists carried by such beams does not exceed<br />

16 feet and the live load on any floor does not exceed 50 lbs/ft 2 . May also be used<br />

on projects exceeding the prescriptive requirements where a professional engineer<br />

is directly involved and the factored resistance requirements are met.<br />

Materials: Top & Bottom Plates (4 1⁄2˝ x 6˝) – 3 gauge;<br />

T2JPLD Light-Duty Tube (2 1⁄2˝ x 2 1⁄2˝) – 11 gauge;<br />

T2JPHD Heavy-Duty Tube (3˝ x 3˝) – 8 gauge<br />

Finish: Tube – Powder Coated Red Paint<br />

Plates – Grey Primer Paint<br />

Codes: Conforms to CAN/CGSB-7.2-94.<br />

Installation:<br />

• Elevate supported beam to the proper height. Turn threaded collar to extend<br />

post to the desired length. Ensure that the top and bottom plates are properly<br />

fastened to the supported beam and aligned properly with the supporting<br />

foundation. Always ensure product is installed 90° to the beam and footing.<br />

Light Duty Type 2 Column<br />

<strong>USP</strong><br />

Adjustable Height Extended Length Allowable Load (100%) 1,3 Factored Resistance (100%) 2,3<br />

Stock No in mm in mm kN Lbs kg kN Lbs kg<br />

T2JPLD84 80 - 84 2032 - 2134 84 2134 75.2 16900 7665 115.8 26000 11813<br />

T2JPLD88 84 - 88 2134 - 2235 88 2235 68.9 15500 7030 108.1 24300 11020<br />

T2JPLD90 86 - 90 2184 - 2286 90 2286 66.7 15000 6805 105.4 23700 10750<br />

T2JPLD96 92 - 96 2337 - 2438 96 2438 60.5 13600 6170 97.4 21800 9936<br />

T2JPLD102 98 - 102 2489 - 2591 102 2591 56.9 12800 5805 89.2 20050 9095<br />

T2JPLD108 104 - 108 2642 - 2743 108 2743 54.3 12200 5535 82.2 18400 8385<br />

T2JPLD120 116 - 120 2946 - 3048 120 3048 48.5 10900 4945 69.8 15600 7119<br />

NEW &<br />

IMPROVED<br />

DESIGN<br />

9/16" hole<br />

for height<br />

adjustment<br />

Type 2 Post<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Heavy Duty Type 2 Column<br />

<strong>USP</strong><br />

Adjustable Height Extended Length Allowable Load (100%) 1,3 Factored Resistance (100%) 2,3<br />

Stock No in mm in mm kN Lbs kg kN Lbs kg<br />

T2JPHD84 80 - 84 2032 - 2134 84 2134 176.1 39600 17960 222.5 49900 22687<br />

T2JPHD88 84 - 88 2134 - 2235 88 2235 162.8 36600 16600 210.4 47300 21455<br />

T2JPHD90 86 - 90 2184 - 2286 90 2286 157.9 35500 16100 206.4 46400 21045<br />

T2JPHD96 92 - 96 2337 - 2438 96 2438 142.8 32100 14560 193.5 43400 19728<br />

T2JPHD102 98 - 102 2489 - 2591 102 2591 133.4 30000 13610 179.3 40300 18280<br />

T2JPHD108 104 - 108 2642 - 2743 108 2743 125.9 28300 12835 167.7 37600 17104<br />

T2JPHD120 116 - 120 2946 - 3048 120 3048 119.2 26800 12155 145.5 32700 14838<br />

1) The Allowable Load values have been determined thru testing standards prescribed in<br />

the National Research Council Evaluation Directive for Adjustable Steel Columns using a<br />

safety factor of 2.25.<br />

<br />

<br />

3) The bearing resistance of the supported beam should be checked by the building designer<br />

using the appropriated CSA standard.<br />

New products or updated product information are designated in red font.<br />

Adjustment<br />

Assembly<br />

HEAVY DUTY<br />

ADJUSTMENT ASSEMBLY<br />

FOR MAXIMUM LOADS<br />

MODULAR DESIGN FOR<br />

GREATEST JOB SITE<br />

FLEXIBILITY<br />

Square Tube<br />

Design<br />

38<br />

SQUARE POST FOR EASY<br />

AND ACCURATE CUT DOWN<br />

USE REBAR/ROD THROUGH<br />

9/16” HOLE FOR HEIGHT<br />

ADJUSTMENT<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

Universal Plate<br />

Type 2 Heavy- Duty Support<br />

Post Accessories on next page


Type 2 Top Plates – T2TP Series<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Type 2 Heavy-Duty Top Plates are compatible with Type 2 Adjustable Support<br />

Posts and provide additional bearing for Structural Composite Lumber (SCL)<br />

beams and dimensional lumber. They are easily placed and aligned on top of the<br />

standard steel column top plate supplied with each <strong>USP</strong> Type 2 column and can<br />

be quickly fastened to the supported beam.<br />

T2TP527 – 5-1/4” bearing width (Typical: 3 ply 1-3/4” LVL or 6x beam)<br />

T2TP79 – 7” bearing width (Typical: 4 ply 1-3/4” LVL or 8x beam)<br />

Materials: 3 gauge ASTM A 36 steel<br />

Finish: <strong>USP</strong> primer<br />

Installation:<br />

• Place Heavy-Duty Top Plate on top of standard Type 2 Top Plate.<br />

• Align holes in Heavy-Duty Top Plate with holes in standard Type 2 Top Plate.<br />

• Install appropriate lag screws through stacked top plates into bottom of<br />

supported beam.<br />

<strong>USP</strong><br />

Stock No.<br />

Dimensions (in)<br />

Fastener Schedule<br />

Factored Resistance<br />

Steel<br />

Bearing (100%) Bearing (100%)<br />

Ref. No. Gauge W L Qty Type Lbs kN Lbs kN<br />

T2TP527 -- -- 3 5-1/4 7 4 1/4" x 2" Lag Screw 29300 131 22600 101<br />

T2TP79 -- -- 3 7 9 4 1/4" x 2" Lag Screw 38500 173 34000 152<br />

1) Factored resistances are for standard term loading; reduce or increase for other load durations in accordance with the code.<br />

2) Bearing loads are based on compression perpendicular to grain values published in the Canadian Standards Association<br />

CSA-O86-09 and having the top plate in full contact with the supported member.<br />

3) Factored resistances are based on lumber with a specific gravity of DF-L = 0.49 and S-P-F = 0.42 and<br />

a moisture content of 19% or less.<br />

4) Lag Screws are not supplied. WS2 Wood Screws (1/4" dia. x 2" long) may be ordered separately and used in lieu of lag screws.<br />

5) Beams shall be designed to support the required loads. Beam shear may limit loads to less than listed loads for device.<br />

6) The factored resistance of the T2TP may exceed the column capacity. Refer to the Type 2 Column load tables for the<br />

maximum factored resistance based on column length.<br />

7) Spliced conditions must be detailed by the specifier to transfer tension loads between spliced members by means<br />

other than the column top plate.<br />

8) The factored resistance must be reduced according to code when supporting the end of the beam.<br />

New products or updated product information are designated in red font.<br />

DF-L<br />

S-P-F<br />

NEW<br />

W<br />

T2TP79<br />

(T2TP527 similar)<br />

Typical T2TP79<br />

installation<br />

(T2TP527 similar)<br />

L<br />

Concrete & Masonry<br />

Type 2 Column Caps – T2CC Series<br />

Cap only version for Type 2 Adjustable Support Posts. Adds<br />

bearing capacity and resists beam rotation.<br />

Materials: T2CC35: 7 gauge ASTM A1011;<br />

T2CC525, T2CC71: 3 gauge ASTM A 36 steel<br />

Finish: <strong>USP</strong> primer<br />

NEW<br />

Installation:<br />

• Replaces standard Type 2 Top Plate.<br />

• Slide column cap tube into top of existing threaded pipe component for complete<br />

adjustability.<br />

• WS3 Wood Screws, ¼”dia. x 3” long, are supplied with T2CC Column Caps.<br />

W<br />

L<br />

T2CC35<br />

H<br />

Dimensions (in)<br />

Fastener<br />

Schedule 4<br />

<strong>USP</strong><br />

Steel<br />

Beam<br />

Bearing (100%) Bearing (100%)<br />

Stock No. Ref. No. Gauge W H L Qty Type Lbs kN Lbs kN<br />

T2CC35 - - 7 3-5/8 6-1/2 11 16 WS3 31270 139.1 23675 105.3<br />

T2CC525 - - 3 5-1/4 8 13 16 WS3 54115 240.7 40970 182.2<br />

T2CC71 - - 3 7-1/8 6-1/2 11 16 WS3 62540 278.2 47350 210.6<br />

1) Factored resistances are for standard term loading; reduce or increase for other load durations in accordance with the code.<br />

2) Bearing loads are based on compression perpendicular to grain values published in CSA O86-09 and having the bucket base in full contact<br />

with the supported member.<br />

3) Factored resistances are based on lumber with a specific gravity of DF-L = 0.49 and S-P-F = 0.42 and a moisture content of 19% or less.<br />

4) WS3 Wood Screws (1/4" dia. x 3" long) are included with T2CC Column Caps.<br />

5) Beams shall be designed to support the required loads. Beam shear may limit loads to less than listed loads for device.<br />

6) The factored resistance of the T2CC may exceed the column capacity. Refer to the Type 2 Column load tables for the maximum factored<br />

resistance based on column length.<br />

7) Spliced conditions must be detailed by the specifier to transfer tension loads between spliced members by means other than the column cap.<br />

8) The factored resistance must be reduced according to code when supporting the end of the beam.<br />

New products or updated product information are designated in red font.<br />

DF-L<br />

Factored Resistance<br />

S-P-F<br />

Typical T2CC<br />

installation<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

39<br />

<strong>USP</strong>2240-131


Holdowns<br />

Predeflected Holdowns . . . . . . . . . Page 41<br />

• PHD & PHDA Series<br />

Connects to wood post with WS series wood screws.<br />

PHD<br />

PHDA<br />

Holdowns . . . . . . . . . . . . . . . . . Pages 42-44<br />

• TD & TDX Series<br />

Standard holdown. Connects to post with bolts.<br />

• UPHD Series<br />

High capacity holdown. Connects to post with wood screws.<br />

Tension Ties . . . . . . . . . . . . . . . . . . . Page 45<br />

• HTT Series<br />

Heavy tension tie. Bolts to foundation and nails to post.<br />

• LTS Series & LTTI31<br />

Light-capacity tension tie. Bolts to foundation and nails to post<br />

Concrete Angles . . . . . . . . . . . . . . . Page 46<br />

TD<br />

HTT<br />

TDX<br />

LTS<br />

UPHD<br />

LTTI31<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Holdowns<br />

• TDL Series<br />

Light-capacity foundation strap. Bolts to foundation and nails or bolts to<br />

post.<br />

TDL<br />

Foundation Straps . . . . . . . . . Pages 46-49<br />

• LSTAD & STAD Series<br />

Embedded strap holdowns for built-up 2x-end posts.<br />

• HPAHD & PAHD42 Series<br />

Embedded strap holdowns for solid end posts.<br />

• TA Series<br />

Straps through masonry foundation wall.<br />

Purlin Anchors . . . . . . . . . . . . . . . . . Page 50<br />

• PA & PAI Series<br />

Embedded strap for concrete to purlin connections.<br />

LSTAD/<br />

STAD<br />

PA<br />

HPAHD PAHD42 TA<br />

PAI<br />

40<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Predeflected Holdowns – PHD & PHDA series<br />

Reduces eccentricity in the studs/post decreased with<br />

centerline dimension. No thru-bolts to countersink.<br />

Materials: See chart.<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted<br />

to various North American building code<br />

evaluators.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Place the PHD/PHDA over the anchor bolt. No washer is<br />

required.<br />

• Install with <strong>USP</strong>’s code evaluated WS3 (1/4˝ x 3˝) Wood<br />

Screws, which are provided with the holdown.<br />

• Tighten anchor bolt nuts finger tight snug to base, plus 1/3<br />

to 1/2 additional turns with a wrench. To prevent loosening of<br />

the anchor nut during critical loading, use a locking nut or<br />

tighten a second nut over the first to lock nuts in place.<br />

• PHD/PHDA Predeflected Holdowns may be installed off<br />

sill plate with no load reduction.<br />

• The design engineer may specify any alternate anchorage<br />

calculated to resist the tension load for a specific application.<br />

Anchorage exposure length should take the bearing plate<br />

height of 15/8˝ into account, anchor bolt thread should visibly<br />

extend above nut.<br />

• If used to anchor a built-up post, such as a double 2 x 4, the<br />

post component shall be designed to act as a single unit.<br />

Holdown fasteners specified shall not be considered to attach<br />

multiple plies together.<br />

• For anchorage options see STBL Anchor Bolt section on<br />

pages 31-32.<br />

W<br />

H<br />

1 5/8˝<br />

CL<br />

D<br />

PHD5A<br />

Typical PHD5A<br />

installation<br />

Holdowns<br />

PHD8<br />

Dimensions (in)<br />

Fastener Schedule<br />

Factored Uplift Resistance (115%) 1,5<br />

<strong>USP</strong><br />

Steel<br />

Anchor Bolts 2 Wood Screws 4 DF-L<br />

S-P-F<br />

Stock No. Ref. No. Gauge W H D CL Qty Dia. Qty Type Lbs kN Lbs kN<br />

PHD2A HDU2-SDS2.5 14 3 7-3/4 2-5/8 1-3/8 1 5/8 6 WS3 3330 14.81 2795 12.43<br />

PHD4A HDU4-SDS2.5 14 3 9-3/4 2-5/8 1-3/8 1 5/8 10 WS3 5400 24.02 4535 20.17<br />

PHD5A HDU5-SDS2.5 14 3 11-11/16 2-5/8 1-3/8 1 5/8 14 WS3 6755 30.05 5670 25.22<br />

PHD8 HDU8-SDS2.5 12 3-1/4 16-1/2 3 1-3/8 1 7/8 24 WS3 8470 37.68 7115 31.65<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) The designer must specify anchor bolt type, length, and embedment.<br />

3) The PHD may be elevated off the sill.<br />

<br />

<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

41<br />

<strong>USP</strong>2240-131


Holdowns – TD & TDX series<br />

TD – Different welded configurations and sizes achieve a great deal of versality within the<br />

TD series.<br />

TDX – The TDX2 and TDX5 feature formed designs, all others are welded. All are<br />

self-jigging. All models, except TD2, TD5, and TD7, feature a self-jigging design with<br />

code required end distances built in. (End distance = 7 bolt diameters from the top<br />

of the sill to the center of the first bolt hole in the studs or post.)<br />

Moisture barrier<br />

may be required<br />

Holdowns<br />

Materials: See chart<br />

Finish: TDX2-TZ – G-185 galvanizing;<br />

All others – <strong>USP</strong> primer<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Do not use lagbolts. Washers are not required for anchor bolts or between holdown and bolt<br />

hex head, but standard washers should be used against stud or post under the nut. See page<br />

20 for BP/LBP Bearing Plates.<br />

• Bolt holes should be a minimum of 1⁄ 32˝ to a maximum of 1⁄16˝ larger than the bolt diameter.<br />

• See pages 31-32 for STB Anchor Bolt section for anchorage options. A design<br />

professional may specify alternate anchorage with conventional anchor bolts.<br />

• A design professional shall determine the adequacy of the stud to resist published loads. When<br />

installing to multi-ply 2x studs, the designer must specify the fasteners required to bind the plies<br />

together and resist splitting.<br />

• Self-jigging models are designed to provide the required minimum end distance of 7 bolt<br />

diameters from the bottom of the stud or post to the centerline of the first bolt hole.<br />

• Tighten anchor bolt nuts to finger tight, plus 1/3 to 1/2 additional turns with a wrench. Wood<br />

members may shrink over time; if possible, nut tightness should be checked periodically. To<br />

prevent loosening of the anchor bolt nut during critical loading, use a locking nut or tighten a<br />

second nut over the first to lock nuts in place.<br />

• If used to anchor a built-up post, such as a double 2 x 4, the post component shall be designed<br />

to act as a single unit. Holdown fasteners specified shall not be considered to attach multiple<br />

plies together.<br />

9/16˝<br />

Typical TDX2-TZ<br />

installation<br />

Typical TDX2-TZ<br />

back-to-back<br />

installation<br />

3 1 /2˝<br />

End<br />

dist.<br />

H<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

W<br />

CL<br />

TDX6<br />

D<br />

Washer required<br />

under anchor<br />

bolt nut<br />

TD15 = 3 3 /8˝<br />

TD9 &<br />

TD12 = 3 1 /2˝<br />

Holdown installation<br />

between floors<br />

Typical TD15<br />

installation<br />

Typical TDX6<br />

installation<br />

continued on next page<br />

42<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Holdowns – TD & TDX series continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>USP</strong><br />

Stock No. 11<br />

TD5<br />

TD7<br />

TD9<br />

TD12<br />

TD15<br />

TDX2-TZ<br />

TDX5<br />

TDX6<br />

TDX8<br />

TDX10<br />

TDX14<br />

Dimensions (in) Fastener Schedule 4 Factored Resistance (115%) 1,2<br />

Bolts<br />

Min.<br />

Length of Bolt in Vertical Member<br />

Required<br />

1-1/2"<br />

3"<br />

3-1/2" 4-1/2" 5-1/2"<br />

Anchor<br />

Bolt End<br />

Steel<br />

Bolt<br />

Distance 5 Wood<br />

Ref. No. Gauge W H D CL Dia. Qty Dia. (in) Species Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN<br />

-- --<br />

-- --<br />

-- --<br />

HD12<br />

-- --<br />

HD3B<br />

-- --<br />

HD5B<br />

HD8A<br />

HD7B<br />

HD9B<br />

7<br />

3<br />

3<br />

3<br />

3<br />

12<br />

10<br />

7<br />

7<br />

7<br />

3<br />

3<br />

3-3/8<br />

3-3/8<br />

3-1/2<br />

3-1/2<br />

2-1/16<br />

2-1/2<br />

3-1/2<br />

3-1/2<br />

3-1/2<br />

3-1/2<br />

6-3/8<br />

11-7/8<br />

16-1/2<br />

20-1/2<br />

25<br />

8-1/8<br />

9-3/8<br />

11-1/8<br />

14-5/8<br />

18-1/8<br />

20-1/2<br />

3-3/4<br />

3-5/8<br />

4-1/4<br />

4-1/4<br />

4-3/8<br />

2-3/4<br />

3-7/8<br />

3-3/4<br />

3-3/4<br />

3-3/4<br />

3-5/8<br />

2-1/8<br />

2-1/8<br />

2-1/8<br />

2-1/8<br />

2-1/8<br />

1-1/2<br />

2<br />

2<br />

2<br />

2<br />

2-1/8<br />

3/4<br />

1-1/8<br />

1-1/8<br />

1-1/8<br />

1-1/4<br />

5/8<br />

3/4<br />

7/8<br />

7/8<br />

7/8<br />

1<br />

2<br />

3<br />

3<br />

4<br />

5<br />

2<br />

2<br />

2<br />

3<br />

4<br />

4<br />

3/4<br />

7/8<br />

1<br />

1<br />

1<br />

5/8<br />

3/4<br />

7/8<br />

7/8<br />

7/8<br />

1<br />

5-1/4<br />

6-1/8<br />

7<br />

7<br />

7<br />

4-1/2<br />

5-1/4<br />

6-1/8<br />

6-1/8<br />

6-1/8<br />

7<br />

DF-L<br />

DF-L<br />

DF-L<br />

DF-L<br />

DF-L<br />

DF-L<br />

DF-L<br />

DF-L<br />

DF-L<br />

DF-L<br />

DF-L<br />

1560<br />

2725<br />

-- --<br />

-- --<br />

-- --<br />

1300<br />

1560<br />

1815<br />

2725<br />

3635<br />

4150<br />

6.94<br />

12.12<br />

-- --<br />

-- --<br />

-- --<br />

5.78<br />

6.94<br />

8.07<br />

12.12<br />

16.17<br />

18.46<br />

3115<br />

5450<br />

6225<br />

8310<br />

10385<br />

2525<br />

3115<br />

3635<br />

5450<br />

7270<br />

8310<br />

13.86<br />

24.24<br />

27.69<br />

36.96<br />

46.19<br />

11.23<br />

13.86<br />

16.17<br />

24.24<br />

32.34<br />

36.96<br />

3635<br />

6360<br />

7270<br />

9690<br />

12110<br />

2525<br />

3635<br />

4240<br />

6360<br />

8480<br />

9690<br />

16.17<br />

28.29<br />

32.34<br />

43.10<br />

53.87<br />

11.23<br />

16.17<br />

18.86<br />

28.29<br />

37.72<br />

43.10<br />

-- --<br />

-- --<br />

9345<br />

12460<br />

15570<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

41.57<br />

55.42<br />

69.26<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

5710<br />

9995<br />

11420<br />

15225<br />

19035<br />

2525<br />

5695<br />

6665<br />

9995<br />

13325<br />

15225<br />

25.40<br />

44.46<br />

50.80<br />

67.72<br />

84.67<br />

11.23<br />

25.33<br />

29.65<br />

44.46<br />

59.27<br />

67.72<br />

S-P-F<br />

S-P-F<br />

S-P-F<br />

S-P-F<br />

S-P-F<br />

S-P-F<br />

S-P-F<br />

S-P-F<br />

S-P-F<br />

S-P-F<br />

S-P-F<br />

1230<br />

2150<br />

-- --<br />

-- --<br />

-- --<br />

1025<br />

1230<br />

1440<br />

2150<br />

2870<br />

3275<br />

5.47<br />

9.56<br />

-- --<br />

-- --<br />

-- --<br />

4.56<br />

5.47<br />

6.41<br />

9.56<br />

12.77<br />

14.57<br />

2460<br />

4300<br />

4915<br />

6555<br />

8195<br />

1795<br />

2460<br />

2870<br />

4300<br />

5740<br />

6555<br />

10.94<br />

19.13<br />

21.86<br />

29.16<br />

36.45<br />

7.98<br />

10.94<br />

12.77<br />

19.13<br />

25.53<br />

29.16<br />

2870<br />

5020<br />

5740<br />

7645<br />

9560<br />

1795<br />

2870<br />

3345<br />

5020<br />

6695<br />

7645<br />

12.77<br />

22.33<br />

25.53<br />

34.01<br />

42.52<br />

7.98<br />

12.77<br />

14.88<br />

22.33<br />

29.78<br />

34.01<br />

-- --<br />

-- --<br />

7375<br />

9835<br />

12295<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

32.81<br />

43.75<br />

54.69<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

4510<br />

7890<br />

9015<br />

12025<br />

15025<br />

1795<br />

4510<br />

5260<br />

7890<br />

10515<br />

12025<br />

20.06<br />

35.10<br />

40.10<br />

53.49<br />

66.83<br />

7.98<br />

20.06<br />

23.40<br />

35.10<br />

46.77<br />

53.49<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) The designer must specify stud or post to resist published load values.<br />

3) The designer must specify anchor bolt type, length, and embedment.<br />

4) All models may be installed with greater than the required anchor end distance with no chart load reduction.<br />

5) The designer shall consider the effect of compression, bearing, tension, and combined bending due to device eccentricity when applicable.<br />

6) Holdowns raised off of the sill plate may have higher deflection values.<br />

Holdowns<br />

Sources of Deflection at the Shearwall Holdown Connections<br />

The following are some of the sources of deflection that should be<br />

evaluated by the designer. See the illustration, which applies to other<br />

holdown configurations.<br />

A. Improperly-sized stud/post bolt holes – increased bolt slip can occur if<br />

stud/post bolt holes are oversized and exceed the NDS ® recommended bolt<br />

hole diameter.<br />

B<br />

C<br />

A<br />

Shearwall<br />

End Post<br />

Bearing<br />

Plates<br />

B. Stud/Post bolt holes – bolt slip can occur.<br />

C. Wood crushing at stud/post bolt hole perimeters –<br />

the use of larger washers/bearing plates can reduce stress-induced wood<br />

crushing at bolt bearing locations.<br />

D. Eccentricity in stud/post caused by holdown –<br />

holdowns installed on only one side of a stud or post result in an eccentricity<br />

which causes increased stresses and movement in a shearwall system.<br />

E. Nut spin – anchor bolt nuts that are not restrained can spin loose during<br />

cyclic loading, allowing movement; the use of steel nylon locking nuts or<br />

thread adhesive may prevent nut spin.<br />

F. Loose nuts – increased movement can occur when nuts are not<br />

sufficiently tightened.<br />

G. Holdown deflection – holdown deflection can occur when the shearwall<br />

system is subjected to cyclic stress from earthquakes or high wind.<br />

H. Wood Shrinkage – due to drying, wood may shrink and cause bolted<br />

connections to become loose; periodic retightening may be required.<br />

I. Localized crushing at wood-bearing surfaces –<br />

excessive crushing at wood-bearing surfaces may result from compressive<br />

forces due to overturning during high wind or earthquake loading.<br />

H<br />

E<br />

G<br />

D<br />

F<br />

Holdown<br />

I<br />

Wood<br />

Sill Plate<br />

Holdown<br />

Anchor Bolt<br />

1 ⁄4˝ x 3˝ x 3˝<br />

Steel Plate<br />

Foundation<br />

Concrete<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

43<br />

<strong>USP</strong>2240-131


Holdowns – UPHD series<br />

Engineered for high capacity with minimum deflection and low eccentricity.<br />

Holdowns<br />

Materials: See chart<br />

Finish: <strong>USP</strong> primer<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Place holdown over anchor bolt and drive screws into post.<br />

• Tighten anchor bolt nuts finger tight snug to base, plus 1/3 to 1/2 additional turns with a<br />

wrench. To prevent loosening of the anchor nut during critical loading, use a locking night or<br />

tighten a second nut over the first to lock nuts in place.<br />

• Holdown may be installed off of the plate with no load reduction.<br />

• Post may be shimmed provided the shim acts as a single unit with the post. Holdown<br />

fasteners specified shall not be considered to attach shim to post. Shim shall be a structural<br />

material equal or better than the post material. Consult a designer or an engineer of record<br />

for appropriate fastening of shim.<br />

Alternate installations:<br />

• Drill hole in concrete or masonry and insert retrofit anchor (i.e. epoxy anchor) capable of<br />

resisting uplift and lateral loading.<br />

• Place holdown over anchor bolt and drive screws into post.<br />

• Tighten anchor bolt nuts finger tight snug to base, plus 2-3 additional turns with a wrench.<br />

To prevent loosening of the anchor nut during critical loading, use a locking nut or tighten a<br />

second nut over the first to lock nuts in place.<br />

• Post may be shimmed provided the shim acts as a single unit with the post. Holdown<br />

fasteners specified shall not be considered to attach shim to post. Shim shall be a structural<br />

material equal or better than the post material. Consult a designer or an engineer of record<br />

for appropriate fastening of shim.<br />

Typical UPHD<br />

installation<br />

W<br />

UPHD<br />

CL<br />

H<br />

D<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Typical UPHD<br />

concrete<br />

wall installation<br />

<strong>USP</strong><br />

Stock No.<br />

Dimensions (in)<br />

Fastener Schedule<br />

Factored Uplift Resistance (115%) 1,5<br />

Steel<br />

Anchor Bolts 3 Wood Screws 4<br />

DF-L<br />

S-P-F<br />

Ref. No. Gauge W H D CL Qty Dia.(in) Qty Type Lbs kN Lbs kN<br />

UPHD8 HDQ8-SDS3 10 3-1/4 17-1/4 3 1-3/8 1 7/8 24 WS3 9485 42.19 7965 35.43<br />

UPHD9 HDU11-SDS2.5 10 3-1/4 17-1/4 3-1/2 1-1/2 1 1 24 WS3 11665 51.89 9800 43.59<br />

UPHD11 HHDQ11-SDS2.5 7 3 15-1/8 3-1/2 1-1/2 1 1 24 WS3 14900 66.28 12515 55.67<br />

UPHD14<br />

HDU14-SDS2.5,<br />

HHDQ14-SDS2.5<br />

7 3 18-3/4 3-1/2 1-1/2 1 1 30 WS3 17280 76.87 14515 64.57<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other<br />

load durations in accordance with the code.<br />

2) The designer must specify anchor bolt type, length, and embedment.<br />

3) The UPHD may be elevated off the sill.<br />

<br />

<br />

44<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Tension Ties – HTT, LTS series & LTTI31<br />

HTT series – Secures multi-ply studs or posts to mudsills or foundation. Nail fastening<br />

makes for a convenient connection to studs or posts in cramped retrofit installations.<br />

LTS series – The LTS19 is designed for nail-on installation to 2x joists or studs, and<br />

the LTS20B provides a nail or bolt fastening option. The LTS20B will accommodate<br />

wood I-Joists if 10d x 1 1 ⁄ 2˝ nails are used instead of the specified 16d nails.<br />

LTTI31 – An open web joist tension tie designed for use with masonry or concrete<br />

construction.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Use all specified fasteners to attach the strap portion of the connector to the side of stud, post, joist,<br />

purlin, or beam. Secure the base to the concrete or masonry wall with specified anchor bolt. A design<br />

professional shall specify the type, length, and embedment of the anchor bolt. No washers required.<br />

• HTT45 Min – Fill all round holes.<br />

• HTT45 Max – Fill all round and diamond holes.<br />

• LTTI31 & LTS connectors must be mounted flush to the surface of the mudsill.<br />

• Factored resistances are based on either nail or bolt fastening; nail and bolt values cannot be combined.<br />

• Washers are not required on transfer plates that fit over the anchor bolt.<br />

• Tighten anchor bolt nuts finger tight snug to base plus, 1/3 to 1/2 additional turns with a wrench.<br />

To prevent loosening of the anchor nut during critical loading, use a locking nut or tighten a second nut<br />

over the first to lock nuts in place.<br />

• Field bending is not required provided minimum fastener edge distance of 3/8" is maintained.<br />

W<br />

L<br />

W<br />

L<br />

NEW<br />

W<br />

3 3/4˝ 6 1/4˝<br />

L<br />

CL<br />

Typical LTTI31<br />

installation<br />

W<br />

D<br />

3/8˝<br />

Typ.<br />

6˝<br />

LTTI31<br />

W<br />

L<br />

11/16˝<br />

2 3 /8˝<br />

6 3 /16˝<br />

Holdowns<br />

1 3/4˝ Typical LTS<br />

CL<br />

HTT16<br />

(HTT22 similar)<br />

D<br />

CL<br />

D<br />

HTT4<br />

(HTT5 similar)<br />

Typical HTT4<br />

installation<br />

HTT45<br />

Typical HTT45<br />

installation<br />

1/4˝<br />

transfer<br />

plate<br />

CL<br />

D<br />

LTS20B<br />

2 1 /2˝<br />

L<br />

Steel Gauge<br />

Dimensions (in)<br />

Fastener Schedule<br />

Strap 2,5<br />

Nail<br />

Anchor<br />

DF-L<br />

S-P-F<br />

<strong>USP</strong><br />

Spacing Bolt 3<br />

Stock No. Ref. No. Strap Plate W L D CL (in) Qty Dia. (in) Qty Type Lbs kN Lbs kN<br />

10d 5700 25.35 4905 21.82<br />

HTT45 (Min)<br />

18<br />

HTT4,<br />

16d x 2-1/2 6710 29.85 5780 25.71<br />

10 -- -- 2-1/2 16 2 1-3/8 1-3/4 1 5/8<br />

HTT5<br />

10d 7515 33.43 6465 28.76<br />

HTT45 (Max)<br />

26<br />

16d x 2-1/2 8505 37.83 7315 32.54<br />

10d x 1-1/2 4695 20.89 4025 17.91<br />

HTT4 HTT4 12 -- -- 3 10-7/16 2-3/4 1-3/8 1-3/4 1 5/8 20 10d 5690 25.33 4880 21.71<br />

16d x 2-1/2 6025 26.81 5165 22.98<br />

10d x 1-1/2 5625 25.02 4820 21.45<br />

HTT5 HTT5 12 -- -- 3 13-15/16 2-3/4 1-3/8 1-3/4 1 5/8 28 10d 7980 35.50 6840 30.43<br />

16d x 2-1/2 7390 32.88 6335 28.18<br />

HTT16 -- -- 10 -- -- 2-1/2 15-5/8 2 1-3/8 1-3/4 1 5/8 18 10d 5355 23.82 3800 16.90<br />

HTT22 -- -- 10 -- -- 2-1/2 21-1/2 2 1-3/8 1-3/4 1 5/8 32 10d 5180 23.04 3680 16.37<br />

LTTI31 4 LTTI31 18 3 3-3/4 31 2-5/8 1-3/8 3 1 5/8 18 10d x 1-1/2 2905 12.92 2440 10.85<br />

LTS19 4 LTT19 16 3 1-3/4 22-1/4 3 1-1/2 2-1/2 1 3/4 8 10d 1245 5.54 1045 4.65<br />

10 10d x 1-1/2 1140 5.07 960 4.27<br />

LTS20B LTT20B 12 3 2 20 3 1-1/2 3-3/4 1 3/4 10 16d 1145 5.09 960 4.27<br />

2 1/2 1215 5.40 1020 4.54<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) 16d sinkers may be substituted for the specified 10d common nails with no load reduction.<br />

3) The designer must specify anchor bolt type, length and embedment depth.<br />

4) LTTI and LTS holdowns shall be installed tight to the sill plate.<br />

5) NAILS:<br />

<br />

New products or updated product information are designated in red font.<br />

Factored Tensile Resistance (115%) 1<br />

1/4˝ transfer<br />

plate<br />

LTS19<br />

Hanger not shown<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

45<br />

<strong>USP</strong>2240-131<br />

CL<br />

D<br />

Installation


Concrete Angles – TDL series<br />

These angles secure wood posts to concrete or wood floors in<br />

light-duty applications.<br />

Holdowns<br />

46<br />

Materials: 12 gauge<br />

Finish: G90 galvanizing<br />

Options: TDL5 available in Triple Zinc. To order, add<br />

TZ to the end of stock number, as in TDL5-TZ .<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• The TDL10 can be embedded into concrete. Minimum<br />

embedment depth is 4˝ to achieve allowable loads.<br />

• Moisture barrier may be required.<br />

Typical TDL10<br />

embedded interior<br />

installation<br />

Dimensions (in) Fastener Schedule 4,5,6 Factored Resistance 1,2,3<br />

Anchor Bolts Strap<br />

Uplift 115%<br />

<strong>USP</strong><br />

Steel<br />

Dia.<br />

DF-L<br />

S-P-F<br />

Stock No. Ref. No. Gauge W H D Qty (in) Qty Type Lbs kN Lbs kN<br />

TDL5 A24 12 2 5-3/16 2-1/4 1 1/2<br />

4 16d 975 4.34 840 3.74<br />

1 1/2 1140 5.07 980 4.36<br />

TDL10 A311 12 2 9-3/4 2-1/4 1 1/2<br />

4 16d 975 4.34 840 3.74<br />

1 1/2 1140 5.07 980 4.36<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake;<br />

reduce for other load durations in accordance with the code.<br />

2) Values given are based on the use of either nails or bolts; nail and bolt values cannot be combined.<br />

<br />

4) Minimum nail embedment shall be 8 nail diameters (typ).<br />

5) Designer must specify anchor bolt type, length, and embedment.<br />

6) NAILS:<br />

Foundation Straps – LSTAD & STAD series<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

4˝ Min.<br />

Typical TDL5<br />

interior installation<br />

D<br />

H<br />

W<br />

TDL10<br />

The coined dimples below the embedment line allow for increased concrete bonding. These holdowns retain<br />

high uplift capacity even when installed at corners of foundation stemwalls. Ideal for use with built up 2x end posts.<br />

LSTAD – 14 gauge one-piece design allows labor effective installation without holdowns.<br />

STAD – 12 gauge design.<br />

RJ after the model indicates LSTAD or STAD for rim joist applications as in STAD8RJ.<br />

Rim joist models provide for a 17˝ clear span without the loss of strap nailing.<br />

Materials: LSTAD – 14 gauge; STAD – 12 gauge<br />

Finish: G90 galvanizing<br />

Codes:<br />

Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

The bottom (2) nails are for form board attachment only and do not contribute to fastener schedule requirements.<br />

• Embed holdown in concrete to the embedment line (bend line).<br />

• See illustrations for requirements on rebar, edge distances, and clear spans.<br />

• Bending the strap horizontally 90° to facilitate wall placement may cause concrete behind the embedded strap to<br />

break away at the top edge (spalling). If the spall is 1˝ or less from the top edge of the concrete, no load reduction<br />

is necessary. If the spall is between 1˝ and 4˝ the allowable load is 0.90 of the published chart load.<br />

•When installing on lumber less than 31/2˝ wide, wood splitting may occur. To reduce splitting, use 10d x 11/2˝ nails<br />

or fill every other hole with 16d common nails. Reduce allowable loads per code requirements accordingly.<br />

• These straps do not secure concrete sections together at cold joints; take other measures to transfer the load. If<br />

there is a cold joint between slab and foundation, the minimum embedment must be made into the foundation.<br />

Fastening opportunities may be reduced because the slab pour level may be higher than some nail holes. Using<br />

fewer fasteners will reduce allowable loads. Reduce allowable load by the code capacity for each fastener not<br />

installed.<br />

• To achieve full table loads the minimum centre-to-centre spacing is twice the embedment depth (IE) when<br />

resisting tension loads at the same time.<br />

• Where fewer fasteners are used in the structural wood member, reduce loads according to the code.<br />

• There may be an increase in the amount of deflection if the strap is installed on the outside of the sheating,<br />

versus directly to the framing members.<br />

• Strap may be bent one complete cycle to aid installation.<br />

continued on next page<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®


Foundation Straps – LSTAD & STAD Series continued<br />

Nailed<br />

portion<br />

W<br />

L<br />

2x embedment length,<br />

+ 12˝ Min. rebar length<br />

Install (1) #4<br />

rebar in<br />

shear cone<br />

12˝ Min.<br />

rebar length<br />

12˝ Min.<br />

rebar length<br />

CS<br />

Install (1)<br />

#4 rebar in<br />

shear cone<br />

30˝ Min.<br />

rebar length<br />

CS<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>USP</strong><br />

Stock No. 5<br />

LSTAD8<br />

LSTAD8RJ<br />

I E<br />

D<br />

LSTAD8<br />

Typical STAD10<br />

edge installation<br />

Edge distance<br />

1/2˝ Min. from corner<br />

Typical STAD10<br />

corner installation<br />

Edge distance<br />

1/2˝ Min. from corner<br />

Typical STAD14RJ<br />

corner rim joist installation<br />

Fastener Dimensions (in)<br />

Factored Resistance Uplift (115%) 4<br />

Schedule 2,3,8,9<br />

DF-L<br />

S-P-F<br />

Min.<br />

Edge Distance - Concrete<br />

Edge Distance - Concrete<br />

Stem<br />

2000 psi 2500 psi 3000 psi 2000 psi 2500 psi 3000 psi<br />

Wall<br />

Ref. No. Qty Type W L l E D CS (in) Unit l E l E l E l E l E l E<br />

LSTHD8<br />

LSTHD8RJ<br />

24<br />

24<br />

Lbs 2765 2765 4000 2765 2765 4000 2765 2765 4000 2320 2320 3360 2320 2320 3360 2320 2320 3360<br />

6<br />

16d<br />

kN 12.30 12.30 17.79 12.30 12.30 17.79 12.30 12.30 17.79 10.32 10.32 14.95 10.32 10.32 14.95 10.32 10.32 14.95<br />

3 21-5/8 8 5 4-5/8<br />

Sinker<br />

Lbs 2765 2765 4000 2765 2765 4000 2765 2765 4000 2320 2320 3360 2320 2320 3360 2320 2320 3360<br />

8<br />

kN 12.30 12.30 17.79 12.30 12.30 17.79 12.30 12.30 17.79 10.32 10.32 14.95 10.32 10.32 14.95 10.32 10.32 14.95<br />

Lbs 2765 2765 4000 2765 2765 4000 2765 2765 4000 2320 2320 3360 2320 2320 3360 2320 2320 3360<br />

6<br />

16d<br />

kN 12.30 12.30 17.79 12.30 12.30 17.79 12.30 12.30 17.79 10.32 10.32 14.95 10.32 10.32 14.95 10.32 10.32 14.95<br />

3 35-1/8 8 5 18-1/8<br />

Sinker<br />

Lbs 2765 2765 4000 2765 2765 4000 2765 2765 4000 2320 2320 3360 2320 2320 3360 2320 2320 3360<br />

8<br />

kN 12.30 12.30 17.79 12.30 12.30 17.79 12.30 12.30 17.79 10.32 10.32 14.95 10.32 10.32 14.95 10.32 10.32 14.95<br />

1) Factored resistances have been increased 15% for short-term load duration; no further increased is allowed.<br />

2) 10d common (0.148" x 3" long) nails may be substituted with no load reduction.<br />

<br />

4) The 115% values are short-term loads such as wind and earthquake.<br />

5) RJ after the model indicates LSTADs for rim joist applications as in LSTAD8RJ.<br />

6) Interpolate allowable loads for edge distances between those listed. Nail quantities may be reduced for<br />

less than lE corner distance design loads- use the code allowable loads for fasteners in shear.<br />

7) Where fewer fasteners are used in the structural wood member, reduce loads according to the code.<br />

8) Minimum nail embedment shall be 8 nail diameters (typ).<br />

9) NAILS: 16d Sinker nails are 0.148" dia. x 3-1/4" long.<br />

CS<br />

W<br />

L<br />

Holdowns<br />

Fastener<br />

Schedule 1,2,10,11<br />

Dimensions (in.)<br />

Min<br />

Stemwall<br />

Factored Resistance (115%)<br />

<strong>USP</strong><br />

Steel<br />

Thickness Edge<br />

Stock No Ref. No.<br />

Ga. Qty Type W L I E D (in.) Distance 4,5 Lbs kN Lbs kN<br />

STAD8<br />

STAD8RJ<br />

STAD10<br />

STAD10RJ<br />

STAD14<br />

STAD14RJ<br />

STHD8<br />

STHD8RJ<br />

STHD10<br />

STHD10RJ<br />

STHD14<br />

STHD14RJ<br />

12<br />

12<br />

12<br />

12<br />

12<br />

12<br />

24<br />

24<br />

28<br />

28<br />

38<br />

38<br />

16d Sinker<br />

16d Sinker<br />

16d Sinker<br />

16d Sinker<br />

16d Sinker<br />

16d Sinker<br />

3<br />

3<br />

3<br />

3<br />

3<br />

3<br />

21-5/8<br />

35-1/8<br />

21-5/8<br />

36<br />

32-1/8<br />

39-5/8<br />

8<br />

8<br />

10<br />

10<br />

14<br />

14<br />

5<br />

5<br />

5<br />

5<br />

5<br />

5<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

1 / 2 " / 2 " / 2 " / 2 " / 2 " / 2 "<br />

3465<br />

3465<br />

3465<br />

3465<br />

7250<br />

7250<br />

15.41<br />

15.41<br />

15.41<br />

15.41<br />

32.25<br />

32.25<br />

2980<br />

2980<br />

2980<br />

2980<br />

6235<br />

6235<br />

13.26<br />

13.26<br />

13.26<br />

13.26<br />

27.74<br />

27.74<br />

1.5 x I E<br />

1.5 x I E<br />

1.5 x I E<br />

1.5 x I E<br />

1.5 x I E<br />

1.5 x I E<br />

5660<br />

5660<br />

5660<br />

5660<br />

8035<br />

8035<br />

25.18<br />

25.18<br />

25.18<br />

25.18<br />

35.74<br />

35.74<br />

4870<br />

4870<br />

4870<br />

4870<br />

6910<br />

6910<br />

21.66<br />

21.66<br />

21.66<br />

21.66<br />

30.74<br />

30.74<br />

1) Predrilled holes are not required.<br />

2) When 16d Sinker nails are specified, 10d common (0.148" diameter x 3" long) nails may be substituted with no load reduction.<br />

3) Wood thickness shall be no less than 3 inches (2 - 2x members)<br />

4) An edge distance of 1/2" implies that the distance from the corner of the wall to the edge of the strap is no less than 1/2".<br />

5) An edge distance of 1.5 x I E implies that the minimum distance from the corner of the wall to the centerline of the strap is no less than 1.5 times the embedment depth.<br />

6) For edge distances between 1/2" and 1.5 x l E calculate loads using straight line interpolation.<br />

7) Minimum anchor spacing for full capacity is 2 x l E . For spacing less than that reduce capacity proportionally.<br />

8) Minimum concrete strength f'c = 2500 psi<br />

9) Minimum 1-#4 rebar shall be installed in the shear cone<br />

10) Minimum nail embedment shall be 8 nail diameters (typ).<br />

11) NAILS: 16d Sinker nails are 0.148" dia. x 3-1/4" long.<br />

DF-L<br />

S-P-F<br />

I E<br />

D<br />

STAD<br />

W<br />

L<br />

CS<br />

I E<br />

D<br />

STAD_RJ<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

47<br />

<strong>USP</strong>2240-131


Foundation Straps – HPAHD & PAHD42<br />

Holdowns<br />

Designed to anchor wood framing to poured concrete foundations.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to various North<br />

American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10 .<br />

• Bending the strap horizontally 90° to facilitate wall placement may cause<br />

concrete behind the embedded strap to break away at the top edge (spalling).<br />

If the spall is 1˝ or less from the top edge of the concrete, no load reduction is<br />

necessary. If the spall is between 1˝ and 4˝, the allowable load is 0.90 of the<br />

published chart load.<br />

• When installing on lumber less than 31⁄2˝ wide, wood splitting may occur. To<br />

reduce splitting, use 10d x 11⁄2˝ nails or fill every other hole with 16d common<br />

nails. Reduce factored resistances in accordance with code requirements.<br />

• Straps are to be installed at the edge of concrete. Install prior to pour by nailing<br />

to form. Drive temporary nails through lowest two nail holes into form. Concrete<br />

level should reach embedment line; minimum embedment depths are listed in<br />

chart.<br />

• Do not rely on these straps to secure concrete sections together between cold<br />

joints; take other measures to transfer the load. If there is a cold joint between slab<br />

and foundation, the minimum embedment must be made into the foundation.<br />

Fastening opportunities may be reduced because the slab pour level may be<br />

higher than some nail holes. Using fewer fasteners will reduce factored<br />

resistances. Reduce factored resistance by the code capacity for each fastener<br />

not installed.<br />

• Factored resistances based on a minimum concrete compressive strength of<br />

2,500 psi at 28 days, with one #4 horizontal rebar in the shear cone. Rebar should<br />

be a minimum length of 2x embedment depth plus 12˝ (see chart for exceptions in<br />

corner installations).<br />

• Where fewer fasteners are used in the structural wood member, reduce loads<br />

according to the code.<br />

• There may be an increase in the amount of deflection if the strap is installed on<br />

the outside of the sheathing, versus directly to the framing members.<br />

• Strap may be bent one complete cycle to aid installation.<br />

NEW<br />

30˝ Min.<br />

rebar length<br />

2x embedment<br />

length + 12˝ Min.<br />

rebar length<br />

Typical HPAHD22<br />

single pour edge<br />

installation<br />

Install (1) #4<br />

rebar in<br />

shear cone<br />

Install (1)<br />

#4 rebar in<br />

shear cone<br />

12˝ Min.<br />

rebar<br />

length<br />

1/2˝ Min.<br />

from corner<br />

Typical HPAHD22<br />

single pour corner and<br />

endwall installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

W<br />

W<br />

W<br />

Embedment<br />

line<br />

H 1<br />

Embedment<br />

line<br />

H 1<br />

(1) #4 rebar<br />

in shear<br />

cone<br />

Nailed<br />

portion<br />

13 1 /2˝<br />

H 1<br />

lE<br />

lE<br />

LE lE<br />

D<br />

D<br />

HPAHD<br />

D<br />

PAHD42<br />

HPAHD22 form board<br />

installation<br />

Typical HPAHD22<br />

single pour rim joist<br />

installation<br />

1/2˝ min.<br />

from corner<br />

48<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

continued on next page


Foundation Straps – HPAHD & PAHD42 continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Schedule 1,2,3<br />

Fastener Dimensions (in.)<br />

Factored Resistance (115%)<br />

Min<br />

Stemwall<br />

DF-L<br />

S-P-F<br />

<strong>USP</strong> Ref. Steel<br />

Thickness Edge<br />

Stock No No. Ga. Qty Type W L I E D (in.) Distance 4,5 Concrete 9,10 Lbs kN Lbs kN<br />

HPAHD22 -- -- 10 23 16d 2-1/16 24-3/4 9-1/2 4-1/8 6<br />

1 Uncracked 4780 21.262 4330 19.261<br />

/ 2 "<br />

Cracked 3345 14.879 3345 14.879<br />

Uncracked 5345 23.776 4330 19.261<br />

1.5 x I E<br />

Cracked 3745 16.659 3745 16.659<br />

PAHD42 -- -- 12 1 Uncracked 2555 11.365 2555 11.365<br />

/ 2 "<br />

Cracked 1785 7.9401 1785 7.9401<br />

15 16d 2-1/16 16-5/8 8 5-3/4 6<br />

Uncracked 4675 20.795 3495 15.547<br />

1.5 x I E<br />

Cracked 3275 14.568 3275 14.568<br />

1) A 16d Common nail has a diameter of 0.162 inch and a length of 3-1/2 inches.<br />

2) Predrilled holes are not required<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) An edge distance of 1/2" implies that the distance from the corner of the wall to the edge of the strap is no less than 1/2".<br />

5) An edge distance of 1.5 x IE implies that the minimum distance from the corner of the wall to the centerline of the strap is<br />

no less than 1.5 times the embedment depth.<br />

6) For edge distances between 1/2" and 1.5 x lE calculate loads using straight line interpolation.<br />

7) Minimum anchor spacing for full capacity is 2 x lE. For spacing less than that reduce capacity proportionally.<br />

8) The allowable loads are based on lumber with a specific gravity of 0.49 for DF-L and 0.42 for S-P-F with a moisture content of 19% or less.<br />

9) Minimum concrete strength f'c = 2500 psi<br />

10) Minimum 1-#4 rebar shall be installed in the shear cone<br />

New products or updated product information are designated in red font.<br />

Foundation Straps – TA series<br />

Foundation Straps offer an economical, one-piece method of achieving a<br />

continuous load path from a 2 x 8, 2 x 10, 2 x 12, or 2 x 14 rim joist<br />

through concrete block to foundation. All models require a 6˝<br />

embedment into concrete footings.<br />

Materials: 12 gauge<br />

Finish: G90 galvanizing<br />

Finish: TA51 and TA71 are available in Triple Zinc. To order<br />

add TZ to stock number, as in TA51-TZ<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

NEW<br />

Double<br />

2 X 10<br />

rim joist<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Factored resistances are based on either nail fastening or bolt fastening; nail and bolt values<br />

cannot be combined.<br />

• Install by inserting product into footing’s wet concrete. All models require a 6˝ embedment into<br />

concrete foundations. Courses of concrete block must be laid over connector. Notch mudsill at<br />

connector locations. Wrap strap over rim joist and fasten.<br />

• Do not rely on these straps to secure concrete sections together between cold joints; take other<br />

measures to transfer the load. If there is a cold joint between block and foundation, the minimum<br />

embedment must be made into the foundation.<br />

• Based on product embedment the exposed number of fastener holes may be reduced. Using<br />

fewer fasteners will reduce allowable loads. Reduce factored resistance by the code prescribed<br />

factored resistance per fastener, for each fastener not installed.<br />

• Factored resistances are based on a minimum concrete compressive strength of 2,000 psi at<br />

28 days.<br />

2 1/4˝<br />

Dimensions (in) Factored Uplift Resistance (115%)<br />

L1<br />

2 x 8 2 x 10 2 x 12 2 x 14<br />

Fastener Uplift 2 Fastener Uplift 2 Fastener Uplift 2 Fastener Uplift 2<br />

Schedule 1,3,4,5 Schedule 1,3,4,5 Schedule 1,3,4,5<br />

Schedule 1,3,4,5<br />

<strong>USP</strong> Ref.<br />

Stock No. No. W L L1 Qty Type DF-L S-P-F Qty Type DF-L S-P-F Qty Type DF-L S-P-F Qty Type DF-L S-P-F<br />

Bolt Uplift Values & Schedules for Rim Joist Sizes Below<br />

TA51 PA51 48-1/4<br />

L<br />

2-1/16 22-1/8 2 1/2 3335 2615 3 1/2 2615 4 1/2 2615 5 1/2 2615<br />

TA71 PA68 68-1/4<br />

Nail Uplift Values & Schedules for Rim Joist Sizes Below<br />

TA51 PA51 48-1/4<br />

2-1/16 22-1/8 8 1965 1965 14 3635 16 3635 <br />

TA71 PA68 68-1/4<br />

<br />

<br />

<br />

<br />

5) Nails:<br />

red font.<br />

TA<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

49<br />

<strong>USP</strong>2240-131<br />

6˝ Min.<br />

Typical TA<br />

installation<br />

Typical TA<br />

stud to foundation<br />

installation<br />

W<br />

Double<br />

2 X 10<br />

rim joist<br />

Holdowns


Purlin Anchors – PA & PAI series<br />

PA series – For installation into poured concrete or concrete block walls and foundations.<br />

PAI series – For wood I-Joist applications. An expanded 3˝ on-centre nail spacing reduces splitting along<br />

I-Joist flange.<br />

Holdowns<br />

50<br />

Materials: 12 gauge<br />

Finish: G90 galvanizing<br />

Options: PA18, PA23 and PA28 are available in Triple Zinc.<br />

To order, add TZ to end of stock number, as in PA18-TZ.<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

Typical PA purlin<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Minimum concrete strength is 2,000 psi.<br />

installation<br />

• The factored resistance for bolts are based on parallel to grain loading with a 3˝ minimum<br />

member thickness. Reduce load per code requirements when minimum member thickness is<br />

not achieved.<br />

• Minimum concrete edge distance is 4˝ for PA & PAI series.<br />

• Minimum concrete block edge distance is 20˝.<br />

• Designer may specify alternate fastening schedules. Refer to Nail Specification Table on<br />

page 14 for nail shear values. Load values shall not exceed published factored resistance.<br />

• No anchor bolts are needed for achieving efficient stress transfer from framing to concrete<br />

walls or foundations.<br />

Minimum<br />

Embedment<br />

Qty Stock No. Ref. No. (in)<br />

Type Lbs kN Lbs kN Lbs kN Lbs kN<br />

DF-L S-P-F<br />

Concrete Masonry Concrete Masonry<br />

<strong>USP</strong><br />

L<br />

Min<br />

Maximum Capacity<br />

PA18<br />

PA23<br />

PA28<br />

PA35<br />

PA18<br />

PA23<br />

PA28<br />

PA35<br />

18-1/2<br />

23-3/4<br />

29<br />

35<br />

4<br />

4<br />

4<br />

4<br />

6<br />

6<br />

6<br />

6<br />

12<br />

15<br />

15<br />

15<br />

16d<br />

16d<br />

16d<br />

16d<br />

3200<br />

4175<br />

4175<br />

4175<br />

14.23<br />

18.57<br />

18.57<br />

18.57<br />

3200<br />

3770<br />

3770<br />

3770<br />

14.23<br />

16.77<br />

16.77<br />

16.77<br />

2685<br />

3505<br />

3505<br />

3505<br />

11.94<br />

15.59<br />

15.59<br />

15.59<br />

2685<br />

3165<br />

3165<br />

3165<br />

11.94<br />

14.08<br />

14.08<br />

14.08<br />

2<br />

3<br />

4<br />

4<br />

1/2<br />

1/2<br />

1/2<br />

1/2<br />

2340<br />

3380<br />

4185<br />

4185<br />

10.41<br />

15.04<br />

18.62<br />

18.62<br />

2340<br />

3380<br />

3770<br />

3770<br />

10.41<br />

15.04<br />

16.77<br />

16.77<br />

1965<br />

2840<br />

3515<br />

3515<br />

8.74<br />

12.63<br />

15.64<br />

15.64<br />

1965<br />

2840<br />

3165<br />

3165<br />

8.74<br />

12.63<br />

14.08<br />

14.08<br />

PAI18 PAI18 18-1/2 4 6 12 10d x 1-1/2 2565 11.41 2565 11.41 2155 9.59 2155 9.59<br />

PAI23 PAI23 23-1/2 4 6 18 10d x 1-1/2 3845 17.10 3770 16.77 3230 14.37 3165 14.08<br />

PAI28 PAI28 28-1/2 4 6 24 10d x 1-1/2 4595 20.44 3770 16.77 3860 17.17 3165 14.08<br />

PAI35 PAI35 35-1/2 4 6 26 10d x 1-1/2 4595 20.44 3770 16.77 3860 17.17 3165 14.08<br />

2x & 3x Ledger<br />

PA18<br />

PA23<br />

PA28<br />

PA35<br />

PA18<br />

PA23<br />

PA28<br />

PA35<br />

18-1/2<br />

23-3/4<br />

29<br />

35<br />

4<br />

4<br />

4<br />

4<br />

6<br />

6<br />

6<br />

6<br />

12<br />

15<br />

15<br />

15<br />

16d<br />

16d<br />

16d<br />

16d<br />

3200<br />

4175<br />

4175<br />

4175<br />

14.23<br />

18.57<br />

18.57<br />

18.57<br />

3200<br />

3770<br />

3770<br />

3770<br />

14.23<br />

16.77<br />

16.77<br />

16.77<br />

2685<br />

3505<br />

3505<br />

3505<br />

11.94<br />

15.59<br />

15.59<br />

15.59<br />

2685<br />

3165<br />

3165<br />

3165<br />

11.94<br />

14.08<br />

14.08<br />

14.08<br />

2<br />

3<br />

4<br />

4<br />

1/2<br />

1/2<br />

1/2<br />

1/2<br />

2340<br />

3380<br />

4185<br />

4185<br />

10.41<br />

15.04<br />

18.62<br />

18.62<br />

2340<br />

3380<br />

3770<br />

3770<br />

10.41<br />

15.04<br />

16.77<br />

16.77<br />

1965<br />

2840<br />

3515<br />

3515<br />

8.74<br />

12.63<br />

15.64<br />

15.64<br />

1965<br />

2840<br />

3165<br />

3165<br />

8.74<br />

12.63<br />

14.08<br />

14.08<br />

PAI18 PAI18 18-1/2 4 6 12 10d x 1-1/2 2565 11.41 1925 8.56 2155 9.59 1615 7.18<br />

PAI23 PAI23 23-1/2 4 6 18 10d x 1-1/2 3635 16.17 3635 16.17 3050 13.57 3050 13.57<br />

PAI28 PAI28 28-1/2 4 6 24 10d x 1-1/2 4595 20.44 3770 16.77 3860 17.17 3165 14.08<br />

PAI35 PAI35 35-1/2 4 6 26 10d x 1-1/2 4595 20.44 3770 16.77 3860 17.17 3165 14.08<br />

4x Ledger<br />

PA18<br />

PA23<br />

PA28<br />

PA35<br />

PA18<br />

PA23<br />

PA28<br />

PA35<br />

18-1/2<br />

23-3/4<br />

29<br />

35<br />

4<br />

4<br />

4<br />

4<br />

6<br />

6<br />

6<br />

6<br />

12<br />

15<br />

15<br />

15<br />

16d<br />

16d<br />

16d<br />

16d<br />

3200<br />

4175<br />

4175<br />

4175<br />

14.23<br />

18.57<br />

18.57<br />

18.57<br />

3200<br />

3770<br />

3770<br />

3770<br />

14.23<br />

16.77<br />

16.77<br />

16.77<br />

2685<br />

3505<br />

3505<br />

3505<br />

11.94<br />

15.59<br />

15.59<br />

15.59<br />

2685<br />

3165<br />

3165<br />

3165<br />

11.94<br />

14.08<br />

14.08<br />

14.08<br />

2<br />

3<br />

4<br />

4<br />

1/2<br />

1/2<br />

1/2<br />

1/2<br />

2340<br />

3380<br />

4185<br />

4185<br />

10.41<br />

15.04<br />

18.62<br />

18.62<br />

2340<br />

3380<br />

3770<br />

3770<br />

10.41<br />

15.04<br />

16.77<br />

16.77<br />

1965<br />

2840<br />

3515<br />

3515<br />

8.74<br />

12.63<br />

15.64<br />

15.64<br />

1965<br />

2840<br />

3165<br />

3165<br />

8.74<br />

12.63<br />

14.08<br />

14.08<br />

PAI18 PAI18 18-1/2 4 6 12 10d x 1-1/2 2355 10.48 1925 8.56 1975 8.79 1615 7.18<br />

PAI23 PAI23 23-1/2 4 6 18 10d x 1-1/2 3205 14.26 3205 14.26 2690 11.97 2690 11.97<br />

PAI28 PAI28 28-1/2 4 6 24 10d x 1-1/2 4595 20.44 3770 16.77 3860 17.17 3165 14.08<br />

PAI35 PAI35 35-1/2 4 6 26 10d x 1-1/2 4595 20.44 3770 16.77 3860 17.17 3165 14.08<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

<br />

3) Values are based on the use of either nails or bolts; nail and bolt values cannot be combined.<br />

4) 16d sinkers or 10d common nails may be substituted for the specified 16d common nails at 0.85 of the table loads.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ).<br />

6) For alternate nail schedule and load values consult <strong>USP</strong>.<br />

7) Minimum quantity of fasteners to be installed. Product may have additional fastener holes not needed to meet published allowable load of product.<br />

Concrete<br />

Masonry<br />

8) NAILS: <br />

Fastener<br />

Schedule 4,5,6,8<br />

Factored Resistance (115%.) 1,3<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

Typical PA holdown<br />

installation<br />

4 Min. concrete<br />

20˝ Min. concrete block<br />

edge distance<br />

Ledger<br />

#4 rebar<br />

min.<br />

4˝<br />

Typical PAI<br />

I-Joist purlin<br />

face installation<br />

1 1 /2˝<br />

4 1 /2˝<br />

PAI<br />

2 1 /16˝<br />

PA<br />

L<br />

2 1 /16˝<br />

L<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®


Caps & Bases<br />

Post Anchors . . . . . . . . . . . . . . . . . . Page 52<br />

• PA, PA(E), & PAU Series<br />

Adjustable wood to concrete post base with 1˝ stand-off fastens with<br />

anchor bolt.<br />

PA PA(E) PAU<br />

Wet Post Anchors . . . . . . . . . . . . . . Page 53<br />

• WAS Series<br />

Wood-to-concrete post base with 1˝ stand-off installs in wet<br />

concrete.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

• WE Series<br />

Wood-to-concrete post base installs in wet concrete.<br />

Elevated Post Bases . . . . . . . . . . . Page 54<br />

• EBG, EPB, & EPBH Series<br />

Elevated post bases with tube support allowing for up to 1˝ clearance.<br />

• APB Series<br />

Adjustable post base allows height adjustments of post after<br />

installation.<br />

Post Anchors . . . . . . . . . . . . . . . . . . Page 55<br />

• D & RSCH Series<br />

Light capacity post anchor nails to post and base.<br />

Column Bases . . . . . . . . . . . . . Pages 55-56<br />

• CBSQ Series<br />

High capacity column base with 1˝ stand-off fastens to column with WS<br />

Wood Screws.<br />

WAS<br />

EBG/EPB<br />

D<br />

WE<br />

EPBH<br />

RSCH<br />

APB<br />

• KCBQ Series<br />

High capacity column base fastens to column with WS Wood Screws.<br />

• CBE Series<br />

Light capacity column base bolts or nails to column.<br />

Post Caps . . . . . . . . . . . . . . . . Pages 57-59<br />

• EPCM & PCM Series<br />

Medium-capacity post to beam connector.<br />

• BC, C, PB, PBES, & PBS Series<br />

Light-capacity post to beam connector.<br />

CBSQ<br />

EPCM<br />

KCBQ<br />

PCM<br />

CBE<br />

BC<br />

C<br />

Caps & Bases<br />

• PBC Series<br />

Light-capacity corner post to beam connector.<br />

PB<br />

PBES<br />

PBS<br />

PBC<br />

Composite Post Bases. . . . . . . . . . Page 59<br />

• CPB Series<br />

Elevated post base to avoid moisture from ground contact.<br />

CPB<br />

Column Caps . . . . . . . . . . . . . . Pages 60-63<br />

• KCCQ & KECCQ Series<br />

Heavy-capacity column to beam connector fastens to column and beam<br />

with WS Wood Screws.<br />

KCCQ<br />

KECCQ<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 51<br />

<strong>USP</strong>2240-131


Post Anchors – PA, PA(E), & PAU series<br />

Caps & Bases<br />

Post Anchors are used to secure wood posts to concrete footings. These post anchors also provide<br />

moisture damage protection and feature a 1˝ stand-off plate to elevate wood posts above concrete surfaces.<br />

PA(E) – 2-sided post anchors with high uplift and bearing capacity.<br />

PA – High capacity utilizing 4-sided design.<br />

PAU – Higher uplift resistance and optional bolt fastening to post.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Options: PA44, PA46, PA66, PA66R, PA44E, PA46E, PA66E, PAU44,<br />

PAU46, PAU66, & PAU88 are available in Triple Zinc.<br />

To order, add TZ to stock number, as in PA44-TZ.<br />

PAU44, PAU46, PAU66, & PAU88 are available in Stainless Steel.<br />

To order, add SS to stock number, as in PAU44-SS.<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. Install with supplied washer.<br />

See Product Notes, page 10.<br />

• Anchor bolts and nails are not furnished.<br />

• Not recommended for fence posts or other<br />

unrestrained (not fixed or fastened at top) applications.<br />

These anchors are not designed to resist overturning<br />

(moment) loads.<br />

• Anchor bolt installation – position specified diameter<br />

anchor bolt at desired location with minimum 4˝ embedment<br />

into 2000 psi concrete. A minimum 2˝ edge distance is<br />

required to achieve factored resistance.<br />

• For hardened concrete or retrofit installations –<br />

use 5/8˝ diameter threaded rod with epoxy adhesive,<br />

follow installation instructions.<br />

NEW<br />

SIZE<br />

Stand-off<br />

plate<br />

Typical PA<br />

installation<br />

Washer<br />

Base<br />

PA<br />

2˝<br />

2 3 /4˝<br />

Typical PA44E<br />

installation<br />

PAU<br />

cross-section<br />

Steel Gauge Dimensions (in)<br />

Fastener Schedule 3,4<br />

Factored Resistance 2<br />

Anchor Bolt<br />

Post<br />

DF-L (Lbs)<br />

DF-L (kN)<br />

S-P-F (Lbs)<br />

S-P-F (kN)<br />

Post/<br />

Nails Bolts<br />

Uplift 1<br />

Uplift 1<br />

Uplift 1<br />

Uplift 1<br />

Column <strong>USP</strong><br />

Stand-off<br />

Bearing Nails Bolts Bearing Nails Bolts Bearing Nails Bolts Bearing Nails Bolts<br />

Size Stock No. Ref. No. Base Plate W H L Qty Dia. Qty Type Qty Dia. 100% 115% 115% 100% 115% 115% 100% 115% 115% 100% 115% 115%<br />

4 x 4 PA44 -- -- 18 12 3-9/16 2-1/8 3-1/2 1 1/2 8 16d -- -- -- -- 8410 720 -- -- 37.41 3.20 -- -- 5970 510 -- -- 26.56 2.27 -- --<br />

4 x 4<br />

Rough<br />

PA44R -- -- 18 12 4-1/16 3-1/2 4 1 1/2 12 16d -- -- -- -- 8410 720 -- -- 37.41 3.20 -- -- 5970 510 -- -- 26.56 2.27 -- --<br />

4 x 4<br />

PA44E -- -- 6 16d -- -- -- -- 11095 1655 -- -- 49.35 7.36 -- -- 7875 1175 -- -- 35.03 5.23 -- --<br />

18 16 3-9/16 3-1/2 3-1/2 1 1/2<br />

PA44E-GC -- -- 6 N16C-GC -- -- -- -- 11095 1655 -- -- 49.35 7.36 -- -- 7875 1175 -- -- 35.03 5.23 -- --<br />

4 x 4 PAU44 ABU44 12 16 3-9/16 5-7/16 3 1 5/8 12 16d 2 1/2 11095 4770 3790 49.35 21.22 16.86 7875 3385 2690 35.03 15.06 11.97<br />

4 x 6 PA46 -- -- 18 12 3-9/16 3-1/2 5-1/2 1 1/2 14 16d -- -- -- -- 10290 955 -- -- 45.77 4.25 -- -- 7305 680 -- -- 32.49 3.02 -- --<br />

4 x 6<br />

Rough<br />

PA46R -- -- 18 10 4-1/16 3-1/2 6 1 1/2 14 16d -- -- -- -- 10290 955 -- -- 45.77 4.25 -- -- 7305 680 -- -- 32.49 3.02 -- --<br />

4 x 6<br />

PA46E ABA46 8 16d 19895 1025 -- -- 88.50 4.56 -- -- 17110 880 -- -- 76.11 3.91 -- --<br />

18 12 3-9/16 3-1/2 5-1/2 1 5/8 -- -- -- --<br />

PA46E-GC -- -- 8 N16C-GC 19895 1025 -- -- 88.50 4.56 -- -- 17110 880 -- -- 76.11 3.91 -- --<br />

4 x 6 PAU46 ABU46 10 12 3-9/16 6 5 1 5/8 12 16d 2 1/2 22625 4770 3790 100.65 21.22 16.86 16065 3385 2690 71.46 15.06 11.97<br />

6 x 6 PA66 -- -- 18 12 5-9/16 3-1/2 5-1/2 1 1/2 16 16d -- -- -- -- 11385 785 -- -- 50.64 3.49 -- -- 8085 555 -- -- 35.96 2.47 -- --<br />

6 x 6<br />

Rough<br />

PA66R -- -- 18 12 6-1/16 3-1/4 6-1/16 1 1/2 16 16d -- -- -- -- 11385 785 -- -- 50.64 3.49 -- -- 8085 555 -- -- 35.96 2.47 -- --<br />

6 x 6<br />

PA66E ABA66 8 16d 26215 1770 -- -- 116.61 7.87 -- -- 18615 1255 -- -- 82.81 5.58 -- --<br />

14 12 5-1/2 3-1/2 5-1/2 1 5/8 -- -- -- --<br />

PA66E-GC -- -- 8 N16C-GC 26215 1770 -- -- 116.61 7.87 -- -- 18615 1255 -- -- 82.81 5.58 -- --<br />

6 x 6<br />

Rough<br />

PA66ER-TZ ABA66R 14 12 6 3-1/4 5-1/2 1 5/8 8 16d -- -- -- -- 26215 1770 -- -- 116.61 7.87 -- -- 18615 1255 -- -- 82.81 5.58 -- --<br />

6 x 6 PAU66 ABU66 10 12 5-1/2 6 5 1 5/8 12 16d 2 1/2 26215 3975 3790 116.61 17.68 16.86 18615 2820 2690 82.81 12.54 11.97<br />

8 x 8 PAU88 ABU88 12 12 7-1/2 7-3/16 7-1/16 2 5/8 14 16d -- -- -- -- 13595 5320 -- -- 60.48 23.67 -- -- 9650 3775 -- -- 42.93 16.79 -- --<br />

8 x 8<br />

Rough<br />

PAU88R ABU88R 12 12 8-1/16 6-15/16 7-1/16 2 5/8 14 16d -- -- -- -- 13595 5320 -- -- 60.48 23.67 -- -- 9650 3775 -- -- 42.93 16.79 -- --<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Factored resistances are based on the use of either nails or bolts; nail and bolt values cannot be combined.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) NAILS:<br />

New products or updated product information are designated in red font.<br />

W<br />

PAU<br />

H<br />

L<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

52<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Wet Post Anchors – WAS & WE series<br />

WAS – A formed base providing a 1˝ stand-off with high<br />

bearing capacity.<br />

Uplift<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

WE – A formed, one-piece design. Includes embossing for<br />

additional lateral strength.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Options: WAS44, WAS46, WAS66, WE44, WE46,<br />

& WE66 are available in Triple Zinc. To<br />

order, add TZ to stock number, as in<br />

WAS44-TZ.<br />

WAS44, WAS66, and WE44 are available<br />

in Hot-dip galvanized. To order, add HDG<br />

to stock number, as in WE44-HDG.<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes,<br />

page 10.<br />

• Insert into wet concrete after the pour. For the WE, embed<br />

the anchor so that the base plate is flush with the surface<br />

of the concrete. For the WAS, embed the anchor until the<br />

concrete surface meets the bottom edge of the stand off<br />

base legs. This will provide a 1˝ stand-off where required.<br />

A 2˝ minimum edge distance is required to achieve<br />

factored resistance.<br />

• Not recommended for fence posts or other<br />

unrestrained (not fixed or fastened at top) applications.<br />

These anchors are not designed to resist overturning<br />

(moment) loads.<br />

H 1<br />

H 2<br />

Typical WE<br />

installation<br />

L<br />

WE<br />

2˝ Min.<br />

edge distance<br />

W 1<br />

2˝ Min.<br />

edge<br />

distance<br />

11 3 /16˝<br />

F 1<br />

F 2<br />

Typical WAS<br />

installation<br />

W 1<br />

H 1<br />

W 2<br />

H 2<br />

WAS<br />

L<br />

1˝ Stand-off<br />

plate<br />

Steel Gauge<br />

Dimensions (in)<br />

Fastener<br />

Factored Resistance 4,5<br />

Post <strong>USP</strong><br />

Schedule 3,5,6<br />

Wood Bearing 100% F1 (115%) 1 F2 (115%) 1 Uplift (115%) 1<br />

Size Stock No. Ref. No. Base Strap W1 W2 H1 H2 2 L Qty Type Species Lbs kN Lbs kN Lbs kN Lbs kN<br />

WE44 PB44 12 12 -- -- <br />

12 16d<br />

DF-L -- -- -- -- 1415 6.29 1470 6.54 1750 7.78<br />

S-P-F -- -- -- -- 1215 5.40 1265 5.63 1505 6.69<br />

2 <br />

DF-L -- -- -- -- 1135 5.05 1270 5.65 1780 7.92<br />

S-P-F -- -- -- -- 975 4.34 1090 4.85 1530 6.81<br />

<br />

DF-L -- -- -- -- 1470 6.54 1415 6.29 1750 7.78<br />

WE44R PB44R 12 12 4 -- -- 5 12 16d<br />

Rough<br />

S-P-F -- -- -- -- 1265 5.63 1215 5.40 1505 6.69<br />

WE46 PB46 12 12 -- -- <br />

12 16d<br />

DF-L -- -- -- -- 1415 6.29 1470 6.54 1750 7.78<br />

S-P-F -- -- -- -- 1215 5.40 1265 5.63 1505 6.69<br />

2 <br />

DF-L -- -- -- -- 1135 5.05 1270 5.65 1780 7.92<br />

S-P-F -- -- -- -- 975 4.34 1090 4.85 1530 6.81<br />

<br />

DF-L -- -- -- -- 1470 6.54 1415 6.29 1750 7.78<br />

WE46R -- -- 12 12 6 -- -- 5 12 16d<br />

Rough<br />

S-P-F -- -- -- -- 1265 5.63 1215 5.40 1505 6.69<br />

WE66 PB66 12 12 -- -- 5 12 16d<br />

DF-L -- -- -- -- -- -- -- -- 2790 12.41 2615 11.63<br />

S-P-F -- -- -- -- -- -- -- -- 2400 10.68 2250 10.01<br />

<br />

DF-L -- -- -- -- -- -- -- -- 2790 12.41 2615 11.63<br />

WE66R PB66R 12 12 6 -- -- 5 12 16d<br />

Rough<br />

S-P-F -- -- -- -- -- -- -- -- 2400 10.68 2250 10.01<br />

<br />

<br />

<br />

WAS44<br />

WAS46<br />

WAS66<br />

PBS44A<br />

PBS46<br />

PBS66<br />

16<br />

12<br />

12<br />

14<br />

14<br />

12<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

5<br />

<br />

<br />

<br />

14<br />

14<br />

14<br />

16d<br />

16d<br />

16d<br />

DF-L<br />

DF-L<br />

DF-L<br />

9755<br />

19895<br />

23045<br />

43.39<br />

88.50<br />

102.51<br />

1750<br />

1750<br />

2615<br />

7.78<br />

7.78<br />

11.63<br />

1620<br />

1620<br />

1915<br />

7.21<br />

7.21<br />

8.52<br />

3235<br />

3235<br />

3420<br />

14.39<br />

14.39<br />

15.21<br />

S-P-F<br />

S-P-F<br />

S-P-F<br />

8390<br />

17110<br />

19820<br />

37.32<br />

76.11<br />

88.17<br />

1505<br />

1505<br />

2250<br />

6.69<br />

6.69<br />

10.01<br />

1395<br />

1395<br />

1645<br />

6.21<br />

6.21<br />

7.32<br />

2780<br />

2780<br />

2940<br />

12.37<br />

12.37<br />

13.08<br />

2<br />

2<br />

2<br />

<br />

<br />

<br />

DF-L<br />

DF-L<br />

DF-L<br />

9755<br />

19895<br />

23045<br />

43.39<br />

88.50<br />

102.51<br />

1760<br />

1850<br />

2695<br />

7.83<br />

8.23<br />

11.99<br />

1620<br />

1620<br />

1915<br />

7.21<br />

7.21<br />

8.52<br />

3235<br />

3235<br />

4530<br />

14.39<br />

14.39<br />

20.15<br />

S-P-F<br />

S-P-F<br />

S-P-F<br />

8390<br />

17110<br />

19820<br />

37.32<br />

76.11<br />

88.17<br />

1515<br />

1590<br />

2320<br />

6.74<br />

7.07<br />

10.32<br />

1395<br />

1395<br />

1645<br />

6.21<br />

6.21<br />

7.32<br />

2780<br />

2780<br />

3895<br />

12.37<br />

12.37<br />

17.33<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) H2 is mimimum embedment length of anchor into concrete.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) Minimum concrete compressive strength shall be 2,000 psi at 28 days.<br />

5) Factored resistances are based on the use of either nails or bolts; nail and bolt values cannot be combined.<br />

6) NAILS:<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 53<br />

<strong>USP</strong>2240-131<br />

Caps & Bases


Elevated Post Bases - EBG, EPB & EPBH series<br />

These post bases allow installers to pre-align posts and pre-set post<br />

heights above concrete floors or footings. By eliminating<br />

post-to-concrete contact, moisture damage is reduced. Elevated<br />

post bases are ideal for building carports, decks or porches. All<br />

series feature convenient nail fastening to post.<br />

NEW<br />

SIZES<br />

1˝ Max.<br />

elevation<br />

Caps & Bases<br />

54<br />

Materials: EPB – 14 gauge tube; 12 gauge steel U-bracket<br />

EBG44 – 16 gauge tube; 16 gauge steel U-bracket<br />

EPBH – U-bracket – 12 gauge HRPO steel;<br />

Stem – 15 mm rebar<br />

Finish: EPB – <strong>USP</strong> primer; EBG44 – G-185 galvanizing;<br />

EPBH – Hot-dip galvanized<br />

Options: EPB4408, EPB4608, and EPB6608 are available<br />

in Hot-dip galvanized. To order, add HDG to stock<br />

number, as in EPB4408-HDG.<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Not recommended for fence posts or other<br />

unrestrained (not fixed or fastened at top) applications. These<br />

anchors are not designed to resist overturning (moment) loads<br />

L<br />

Schedule 3,4<br />

DF-L<br />

S-P-F<br />

Post <strong>USP</strong><br />

Bearing F1 1,2 F2 1,2 Uplift 2 Bearing F1 1,2 F2 1,2 Uplift 2<br />

W<br />

<strong>USP</strong><br />

Dimensions (in) Fastener Schedule 1,2 6 3/8˝<br />

Size Stock No. Ref. No. W L H1 H2 Qty Type Unit 100% 115% 115% 115% 100% 115% 115% 115%<br />

4 x 4 EPBH44<br />

EPB44PHDG,<br />

RCPS3.5HDG<br />

3-1/2 3-3/8 2-3/4 7 4 16d HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />

4 x 6<br />

Rough<br />

EPBH46R RCPS46HDG 4-1/8 5-3/8 3 7 4 16d HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />

6 x 6 EPBH66 RCPS5.5HDG 5-1/2 5-3/8 3 7 4 16d HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />

6 x 6<br />

Rough<br />

EPBH66R RCPS6HDG 6-1/8 5-3/8 3 7 4 16d HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />

4 x 4 EPB4408<br />

EPB44,<br />

Lbs 3045 1115 1075 1140 2620 960 925 980<br />

3-9/16 3 3 8 8 16d<br />

EPB44-12<br />

kN 13.55 4.96 4.78 5.07 11.65 4.27 4.11 4.36<br />

H 2<br />

4 x 6 EPB4608<br />

EPB46,<br />

Lbs 3045 2270 1695 1560 2620 1950 1460 1340<br />

3-9/16 5 3 8 12 16d<br />

EPB46-12<br />

kN 13.55 10.10 7.54 6.94 11.65 8.67 6.49 5.96<br />

6 x 6 EPB6608<br />

EPB66,<br />

Lbs 4665 2270 1695 1560 4010 1950 1460 1340<br />

5-9/16 5 3-3/16 8 12 16d<br />

EPB66-12<br />

kN 20.75 10.10 7.54 6.94 17.84 8.67 6.49 5.96<br />

4 x 4 EBG44-TZ EPB44A 3-9/16 2-3/4 2-3/8 7-1/2 8 16d HDG<br />

Lbs 2485 1100 1180 1085 2135 945 1015 935<br />

kN 11.05 4.89 5.25 4.83 9.50 4.20 4.52 4.16<br />

1) Lateral loads (F1 and F2) are for conditions where pipe extends no more than 1" above the concrete surface.<br />

2) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for<br />

other load durations in accordance with the code.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) NAILS:<br />

New products or updated product information are designated in red font.<br />

Height Adjustable Post Base – APB Series<br />

W L<br />

H 1<br />

H 2<br />

Post Size Stock No. Ref. No. W L H1 H2 Qty Type<br />

4 x 4 APB44 -- -- 3-1/2 3-3/8 2-3/4 6-3/4 4 16d HDG<br />

6 x 6 APB66 -- -- 5-1/2 5-3/8 2-7/8 6-3/4 4 16d HDG<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) NAILS:<br />

Dimensions (in) Fastener<br />

Factored Resistance (115%) 2<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

Typical EPBH<br />

installation<br />

H 1<br />

H 2<br />

W<br />

L<br />

EPBH<br />

Allows height adjustments of post after installation. A maximum height adjustment of 4˝ can be achieved<br />

with this product. Adjustments may be required if original installation is not exact, if there is a greater slope<br />

on a deck than estimated, or if there is heaving or sinking of the post beyond the initial installation. Embed<br />

in concrete a minimum of 6˝. Useful for reducing moisture damage.<br />

Materials: 16 gauge tube; 12 gauge steel U-bracket<br />

Finish: Hot-dip galvanized<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Not recommended for fence posts or other unrestrained<br />

(not fixed or fastened at top) applications. These anchors are not<br />

designed to resist overturning (moment) loads<br />

APB<br />

Typical EBG44-TZ<br />

installation<br />

F 2<br />

F 1<br />

Uplift<br />

EPB/EBG<br />

similar<br />

Typical APB<br />

installation<br />

Bearing<br />

Typical EPB<br />

installation<br />

H 1<br />

3" Min.<br />

edge<br />

distance<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®


© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

Post Anchors – D & RSCH series<br />

Secures nominal sized posts to wood surfaces for light-duty applications.<br />

Materials: See chart<br />

Finish: G90 galvanizing; D44-TZ & D46R-TZ – G-185 galvanizing;<br />

RSCH – Hot-dip galvanized<br />

Options: D46, D66, and D66R are available in Triple Zinc.<br />

To order, add TZ to stock number, as in D46-TZ.<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Not recommended for fence posts or other unrestrained (not fixed or<br />

fastened at top) applications. These anchors are not designed to resist<br />

overturning (moment) loads.<br />

• While D series post anchors offer some lateral and uplift resistance, they<br />

are not recommended as a primary means of anchorage for posts in<br />

railings. They may be used only for intermediate posts between fully<br />

anchored corner / end posts in rail systems.<br />

L<br />

W<br />

H<br />

RSCH<br />

Dimensions (in)<br />

Fastener Schedule 2,3<br />

Factored Resistance 1 (115%)<br />

Post <strong>USP</strong><br />

Steel<br />

Post<br />

Beam<br />

DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Size Stock No. Ref. No. Gauge W H L Qty Nails Qty Nails Bolts F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift<br />

BC40,<br />

D44-TZ<br />

4 x 4<br />

BC40Z<br />

18 3-9/16 2-1/2 3-3/8 8 16d HDG 4 16d HDG -- -- 1920 2065 1345 8.54 9.19 5.98 1365 1465 955 6.07 6.52 4.25<br />

RSCH44 -- -- 12 3-9/16 2-5/8 3-3/8 4 16d HDG 1 -- -- 1/2"Ø -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />

4 x 4 Rough D44R BC40R 18 4 3 3-3/4 8 16d 4 16d -- -- 1920 2065 1345 8.54 9.19 5.98 1365 1465 955 6.07 6.52 4.25<br />

4 x 6 D46 BC460 18 3-9/16 3 5-3/8 10 16d 5 16d -- -- 1920 2065 1345 8.54 9.19 5.98 1365 1465 955 6.07 6.52 4.25<br />

4 x 6 Rough D46R-TZ -- -- 18 4 3 5-3/8 10 16d HDG 5 16d HDG -- -- 1920 2065 1345 8.54 9.19 5.98 1365 1465 955 6.07 6.52 4.25<br />

6 x 6<br />

D66 BC60 18 5-1/2 3 5-3/8 10 16d 5 16d -- -- 1920 2065 1345 8.54 9.19 5.98 1365 1465 955 6.07 6.52 4.25<br />

RSCH66 -- -- 12 5-9/16 2-7/8 5-3/8 4 16d HDG 1 -- -- 1/2"Ø -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />

6 x 6 Rough D66R BC60R 18 6 3 5-3/8 10 16d 5 16d -- -- 1920 2065 1345 8.54 9.19 5.98 1365 1465 955 6.07 6.52 4.25<br />

8 x 8 D88 BC80 18 7-1/2 3 7-3/8 12 16d 5 16d -- -- 1920 2065 1345 8.54 9.19 5.98 1365 1465 955 6.07 6.52 4.25<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

New products or updated product information are designated in red font.<br />

Column Bases – CBSQ series<br />

These column bases install using <strong>USP</strong>’s WS2-HDG Wood Screws, reducing installation time<br />

and cost. Designed for high uplift in high wind or seismic applications. Includes a stand-off<br />

plate to protect the wood from ground contact moisture.<br />

Materials: See chart<br />

Finish: G-185 galvanizing<br />

Options: CBSQ44, CBSQ46, and CBSQ66 are available in Hot-dip galvanized.<br />

To order, add HDG to stock number, as in CBSQ44-HDG.<br />

NEW<br />

SIZE<br />

D<br />

F2<br />

1˝<br />

standoff<br />

F1<br />

Typical D<br />

installation<br />

Uplift<br />

3˝ Min. edge<br />

distance<br />

Typical CBSQ44-TZ<br />

installation<br />

L<br />

Caps & Bases<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• WS2-HDG Wood Screws, 1/4˝ dia. x 2˝ long, are supplied with CBSQ Bases.<br />

• All models require a minimum edge distance of 3˝.<br />

• Embed the column base until the concrete surface meets the bottom edge of the stand-off<br />

plate.<br />

• Not recommended for fence posts or other unrestrained (not fixed or fastened at top)<br />

applications. These bases are not designed to resist overturning (moment) loads.<br />

H<br />

W 2<br />

7 3 /16˝<br />

W 1<br />

CBSQ44-TZ<br />

Column<br />

Size<br />

<strong>USP</strong><br />

Stock No.<br />

Steel Gauge Dimensions (in) Fastener<br />

Factored Resistance<br />

Schedule 2,3 DF-L<br />

S-P-F<br />

Bearing 100% Uplift 115% 1 Bearing 100% Uplift 115% 1<br />

Ref. No. Strap Base W1 W2 H L Qty Type Lbs kN Lbs kN Lbs kN Lbs kN<br />

4 x 4 CBSQ44-TZ CBSQ44-SDS2 10 16 3-9/16 3-1/2 8-3/4 2-1/4 14 WS2-HDG 9725 43.26 9895 44.02 8365 37.21 8510 37.86<br />

4 x 6 CBSQ46-TZ CBSQ46-SDS2 10 12 3-9/16 5-7/16 8-3/4 2-1/4 14 WS2-HDG 19895 88.50 9895 44.02 17110 76.11 8510 37.86<br />

6 x 6 CBSQ66-TZ CBSQ66-SDS2 10 12 5-1/2 5-7/16 8-3/4 3 14 WS2-HDG 23045 102.51 9895 44.02 19820 88.17 8510 37.86<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

<br />

3) Concrete compressive strength shall be 2,000 psi or greater at 28 days.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 55<br />

<strong>USP</strong>2240-131


Column Bases – CBE & KCBQ series<br />

CBE – 12 gauge base for carports, patios, or other residential<br />

framing.<br />

KCBQ – High capacity base fastens with WS wood screws.<br />

H<br />

L<br />

3 3 /16˝<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Options: KCBQ models available in rough/full sizes.<br />

KCBQ44, KCBQ46, KCBQ66 and KCBQ88 are<br />

available in Hot-dip galvanized. To order, add<br />

HDG to stock number, as in KCBQ44-HDG.<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• WS2 Wood Screws, 1/4˝ dia. x 2˝ long, are supplied with KCBQ<br />

Column Bases.<br />

• Not recommended for fence posts or other unrestrained (not<br />

fixed or fastened at top) applications. These bases are not<br />

designed to resist overturning (moment) loads.<br />

• All models require a minimum edge distance of 3˝.<br />

• Bolted models feature diamond holes for temporary nail fastening<br />

to facilitate drilling and bolting.<br />

• Embed column base with bottom of base plate flush to concrete.<br />

W1<br />

7˝<br />

W 1<br />

H<br />

CBE<br />

L<br />

W 2<br />

3˝ Min.<br />

edge distance<br />

W2<br />

Typical CBE<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong>®<br />

8˝<br />

Caps & Bases<br />

Column<br />

Size<br />

4 x 4<br />

4 x 6<br />

KCBQ44<br />

Dimensions (in)<br />

Fastener Factored Uplift Resistance (115%) 1,5<br />

Schedule 2,3,4,5,6,7<br />

DF-L<br />

S-P-F<br />

Steel<br />

Ref. No. Gauge W1 W2 H L Qty Type Lbs kN Lbs kN<br />

2 1/2 6305 28.05 5420 24.11<br />

3-9/16 3-1/2 7-1/2 2<br />

12 16d 4060 18.06 3490 15.52<br />

CB44,<br />

CBQ44-SDS2<br />

10 3-9/16 3-1/2 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

2 1/2 6295 28.00 5415 24.09<br />

12 16d 4060 18.06 3490 15.52<br />

KCBQ46<br />

CB46,<br />

CBQ46-SDS2<br />

10 3-9/16 5-1/2 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

4 x 8 KCBQ48 CB48 10 3-9/16 7-1/2 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

6 x 4 KCBQ64 -- -- 10 5-1/2 3-1/2 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

6 x 6 CBE66 LCB66 12 5-1/2 5-1/2 7-1/2 2<br />

2 1/2 6280 27.93 5400 24.02<br />

12 16d 4060 18.06 3490 15.52<br />

6 x 6 KCBQ66<br />

CB66,<br />

CBQ66-SDS2<br />

10 5-1/2 5-1/2 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

6 x 8 KCBQ68 CB68 10 5-1/2 7-1/2 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

7-1/8 x 3-1/2 KCBQ71-4 CB71/8-4 10 7-1/8 3-1/2 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

7-1/8 x 5-1/2 KCBQ71-6 CB71/8-6 10 7-1/8 5-1/2 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

7-1/8 x 7-1/8 KCBQ71-7 CB71/8-7 10 7-1/8 7-1/8 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

8 x 6 KCBQ86 CB86 10 7-1/2 5-1/2 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

8 x 8 KCBQ88 CB88 10 7-1/2 7-1/2 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

10 x 10 KCBQ1010 CB1010 10 9-1/2 9-1/2 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

10 x 12 KCBQ1012 CB1012 10 9-1/2 11-1/2 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

12 x 12 KCBQ1212 CB1212 10 11-1/2 11-1/2 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

Glulam Sizes<br />

5-1/8<br />

CB5-4.5,<br />

KCBQ5<br />

glulam<br />

CB5-6<br />

10 5-1/4 Spec. 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

6-3/4<br />

KCBQ7<br />

CB7-6, CB7-7.5,<br />

10 6-7/8 Spec. 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

glulam<br />

8-3/4<br />

glulam<br />

<strong>USP</strong><br />

Stock No.<br />

CBE44 LCB44 12<br />

CBE46 LCB46 12<br />

KCBQ9<br />

CB7-9, CB7-10.5<br />

CB9-6, CB9-7.5,<br />

CB9-9, CB9-10.5<br />

3-9/16 5-1/2<br />

7-1/2<br />

10 8-7/8 Spec. 8-3/4 2-1/4 14 WS2 14345 63.81 10605 47.17<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) Concrete compressive strength shall be 2,000 psi or greater at 28 days.<br />

<br />

5) Factored resistances are based on the use of either nails or bolts; nail and bolt values cannot be combined.<br />

6) Bolts shall conform to ASTM A 307 or better.<br />

7) NAILS:<br />

2<br />

KCBQ66<br />

Typical KCBQ66<br />

installation<br />

56<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Post Caps – EPCM & PCM series<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

PCM – Provides a positive connection for medium-duty,<br />

post-to-beam applications.<br />

EPCM – End column caps.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Options: EPCM4416, EPCM4616, EPCM66, EPCM6616,<br />

PCM44, PCM46, PCM66, PCM4416, PCM4616,<br />

PCM4816, and PCM6616 are available in Triple<br />

Zinc. To order, add TZ to stock number, as in<br />

PCM4416-TZ.<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• PCM 16 gauge post caps should not be substituted for PCM 12<br />

gauge post caps unless approved by the Engineer of Record.<br />

<strong>USP</strong><br />

Series<br />

<strong>USP</strong><br />

Stock No.<br />

Ref.<br />

Series<br />

Steel<br />

Gauge<br />

Fastener Schedule 1,2<br />

Post<br />

Beam<br />

Qty Type Qty Type<br />

PCM_16 PC_16 16 8 16d 12 16d<br />

PCM PC 12 8 16d 12 16d<br />

EPCM_16 EPC_16 16 8 16d 8 16d<br />

EPCM EPC 12 8 16d 8 16d<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) NAILS:<br />

Dimensions (in)<br />

DF-L (Lbs)<br />

Factored Resistance (115%) 1<br />

Ref. No. Beam Post W1 W2 H1 L1 L2 F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift<br />

Centre Column Caps<br />

PCM4416 11 1140 6.81 <br />

PCM44 PC44 11 1600 1610 <br />

PCM46 PC46 1600 1610 <br />

PCM4616 1140 6.81 <br />

PCM4816 1140 6.81 <br />

PCM48 PC48 1600 1610 <br />

PCM6416 11 1160 8.12 8.12 <br />

PCM64 PC64 11 1860 1840 <br />

PCM6616 1160 8.12 8.12 <br />

PCM66 PC66 1860 1840 <br />

PCM6816 1160 8.12 8.12 <br />

PCM68 PC68 1860 1840 <br />

1860 1840 <br />

PCM8416 11 1160 8.12 8.12 <br />

PCM84 PC84 11 1860 1840 <br />

PCM8616 1160 8.12 8.12 <br />

PCM86 PC86 1860 1840 <br />

PCM8816 1160 8.12 8.12 <br />

PCM88 PC88 1860 1840 <br />

End Column Caps<br />

EPCM4416 1140 6.81 <br />

EPCM44 EPC44 1600 1610 <br />

EPCM46 EPC46 1600 1610 <br />

EPCM4616 1140 6.81 <br />

EPCM4816 1140 6.81 <br />

EPCM48 EPC48 1600 1610 <br />

EPCM6416 1160 8.12 8.12 <br />

EPCM64 EPC64 1860 <br />

EPCM6616 1160 8.12 8.12 <br />

EPCM66 EPC66 1860 <br />

EPCM6816 1160 8.12 8.12 <br />

EPCM68 EPC68 1860 <br />

1860 <br />

EPCM8416 1160 8.12 8.12 <br />

EPCM84 EPC84 1860 <br />

EPCM8616 1160 8.12 8.12 <br />

EPCM86 EPC86 1860 <br />

EPCM8816 1160 8.12 8.12 <br />

EPCM88 EPC88 1860 <br />

Qty<br />

2) NAILS:<br />

<br />

<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 57<br />

<strong>USP</strong>2240-131<br />

DF-L (kN)<br />

L 2<br />

L1<br />

W 2<br />

PCM<br />

W 1<br />

3 3 /4˝<br />

W 1<br />

L 2<br />

L 1<br />

W 2<br />

EPCM<br />

S-P-F (Lbs)<br />

H1<br />

H 1<br />

3 3/4˝<br />

F 2<br />

Uplift<br />

F 1<br />

S-P-F (kN)<br />

Typical PCM46<br />

installation<br />

<strong>USP</strong><br />

Series<br />

Typical EPCM<br />

installation<br />

Ref.<br />

Series<br />

Steel<br />

Gauge<br />

Caps & Bases<br />

Fas<br />

T


Post Caps – BC, C, PB, PBES, & PBS series<br />

BC – One-piece design for double 2x’s to a 4x post.<br />

C – One-piece design.<br />

PB – Two-piece design.<br />

PBES & PBS – Two-piece design with extended side plates and wrap around post design. Easy retrofit installations.<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing, BC400-TZ, PB44-6TZ & PB66-6TZ – G-185 galvanizing; PB44-6GC & PB66-6GC – Gold Coat<br />

Options: C44, C46, C46R, C66, C66R, PBS44, PBS66, PBS66R, PBES44, & PBES66 are available in Triple Zinc.<br />

To order, add TZ to stock number, as in PBS44-TZ. C44, PBES44, PBES66, PBS44 & PBS66 are available in<br />

Stainless Steel. To order, add SS to stock number, as in C44-SS.<br />

Codes: Load values are derived from data submitted to various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• These products are designed to work with single, solid-sawn beams, but can be used with built-up beams. When installed to<br />

multiple beams made up of 2x lumber and shims, fasten the plys and shims together to act as a unit.<br />

• PB, PBES, and PBS post caps are to be installed in pairs.<br />

Uplift<br />

F2<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

F 1<br />

Typical BC400-TZ<br />

installation<br />

Typical C44<br />

installation<br />

Typical PB-TZ<br />

installation<br />

Typical PBS<br />

installation<br />

Typical PBES<br />

installation<br />

Caps & Bases<br />

L 1<br />

W 2<br />

H 2<br />

H 1<br />

W 1<br />

BC400-TZ<br />

L W 2 1<br />

H 2<br />

H 1<br />

L1<br />

C44<br />

W 2<br />

L 1<br />

H 2<br />

H 1<br />

W1<br />

PB44-6TZ<br />

L 2<br />

L 1<br />

H 1<br />

H2<br />

H1<br />

L2<br />

W1<br />

PBES<br />

Dimensions (in)<br />

Fastener Schedule 2,3,4<br />

Factored Resistance (115%) 1,2<br />

Post <strong>USP</strong><br />

Post Beam DF-L (Lbs)<br />

DF-L (kN)<br />

S-P-F (Lbs)<br />

S-P-F (kN)<br />

Size Stock No. Ref. No. W1 W2 H1 H2 L1 L2 Qty Type Qty Type F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift<br />

4 x 4 BC400-TZ<br />

BCS2-2/4,<br />

BCS2-2/4Z<br />

3-9/16 3-1/8 2-3/8 3 3-5/16 -- -- 10 10d x -12 HDG 8 10d x -12 HDG 1280 845 1005 5.69 3.76 4.47 905 60 715 4.03 0.27 3.18<br />

4 x 4 C44 BC4 3-9/16 3-9/16 2-7/8 2-7/8 3-1/4 3-1/4 6 16d 6 16d 2220 2220 1885 9.88 9.88 8.39 1575 1575 1340 7.01 7.01 5.96<br />

4 x 4<br />

Rough<br />

C44R BC4R 4 4 2-5/8 2-5/8 3-1/4 3-1/4 8 16d 8 16d 2220 2220 1885 9.88 9.88 8.39 1575 1575 1340 7.01 7.01 5.96<br />

4 x 6 C46 BC46 3-9/16 5-1/2 2-9/16 2-5/8 3-3/8 5-1/4 6 16d 10 16d 2220 2220 1885 9.88 9.88 8.39 1575 1575 1340 7.01 7.01 5.96<br />

4 x 6<br />

Rough<br />

C46R -- -- 4 6 2-3/4 2-3/4 3-1/4 5-1/4 8 16d 10 16d 2220 2220 1885 9.88 9.88 8.39 1575 1575 1340 7.01 7.01 5.96<br />

6 x 6 C66 BC6 5-1/2 5-1/2 2-7/8 2-7/8 5-1/4 5-1/4 12 16d 12 16d 4125 4125 2270 18.35 18.35 10.10 2925 2925 1610 13.01 13.01 7.16<br />

6 x 6<br />

Rough<br />

C66R BC6R 6 6 2-13/16 2-13/16 5-1/4 5-1/4 10 16d 10 16d 4360 4360 2055 19.40 19.40 9.14 3095 3095 1455 13.77 13.77 6.47<br />

8 x 8 C88 BC8 7-1/2 7-1/2 5 5 7-3/8 7-3/8 16 16d 16 16d 4360 4360 2120 19.40 19.40 9.43 3095 3095 1505 13.77 13.77 6.69<br />

4 x 4 - 6<br />

6 x 6 - 6<br />

PB44-6TZ 2<br />

PB66-6TZ 2 LPC4Z<br />

LPC6Z<br />

1-1/2<br />

1-1/2<br />

-- --<br />

-- --<br />

2-1/8<br />

2-1/2<br />

1-1/2<br />

3<br />

3-5/8<br />

5-9/16<br />

-- --<br />

-- --<br />

8<br />

8<br />

16d HDG<br />

16d HDG<br />

8<br />

8<br />

16d HDG<br />

16d HDG<br />

1885<br />

1885<br />

665<br />

665<br />

1210<br />

1210<br />

8.39<br />

8.39<br />

2.96<br />

2.96<br />

5.38<br />

5.38<br />

1340<br />

1340<br />

470<br />

470<br />

855<br />

855<br />

5.96<br />

5.96<br />

2.09<br />

2.09<br />

3.80<br />

3.80<br />

PB44-6GC 2<br />

PB66-6GC 2 -- --<br />

-- --<br />

1-1/2<br />

1-1/2<br />

-- --<br />

-- --<br />

2-1/8<br />

2-1/2<br />

1-1/2<br />

3<br />

3-5/8<br />

5-9/16<br />

-- --<br />

-- --<br />

8<br />

8<br />

N16C-GC<br />

N16C-GC<br />

8<br />

8<br />

N16C-GC<br />

N16C-GC<br />

1885<br />

1885<br />

665<br />

665<br />

1210<br />

1210<br />

8.39<br />

8.39<br />

2.96<br />

2.96<br />

5.38<br />

5.38<br />

1340<br />

1340<br />

470<br />

470<br />

855<br />

855<br />

5.96<br />

5.96<br />

2.09<br />

2.09<br />

3.80<br />

3.80<br />

4 x 4 PBES44 2 ACE4,<br />

LCE4<br />

1-1/2 -- -- 2-3/8 2-3/4 3-1/4 4-3/4 8 16d 8 16d 1915 1050 4150 8.52 4.67 18.46 1355 745 2950 6.03 3.31 13.12<br />

6 x 6 PBES66 2 ACE6 1-1/2 -- -- 2-3/8 2-1/8 5-1/2 7 8 16d 8 16d 2400 1685 3480 10.68 7.50 15.48 1700 1195 2475 7.56 5.32 11.01<br />

4 x 4 PBS44 2 AC4 1-7/16 -- -- 2-5/16 2-13/16 3-9/16 6-1/2 12 16d 12 16d 3800 2250 5850 16.90 10.01 26.02 2695 1600 4150 11.99 7.12 18.46<br />

4 x 4<br />

Rough<br />

PBS44R 2 AC4R 1-1/2 -- -- 2-5/16 2-3/16 4 7 8 16d 8 16d 1915 1050 4150 8.52 4.67 18.46 1355 745 2950 6.03 3.31 13.12<br />

6 x 6 PBS66 2 AC6 1-1/4 -- -- 2-5/16 2-7/8 5-1/2 8 14 16d 12 16d 3785 2190 4295 16.84 9.74 19.11 2685 1560 3045 11.94 6.94 13.55<br />

6 x 6<br />

Rough<br />

PBS66R AC6R 1-1/4 -- -- 2-5/16 2-3/16 6 8-1/2 10 16d 10 16d 2400 1685 3480 10.68 7.50 15.48 1700 1195 2475 7.56 5.32 11.01<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Factored resistances and nail schedules for two-piece models are per pair of post caps.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) NAILS:<br />

New products or updated product information are designated in red font.<br />

W1<br />

PBS<br />

H 2<br />

L1<br />

58<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Post Beam Corner – PBC series<br />

The PBC series is a one-piece connector designed to secure two<br />

mitered beams on a corner post while providing uplift capacity.<br />

Materials: 18 gauge<br />

Finish: G-185 galvanizing<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Install PBC on outside corner of post forming tabs to inner side<br />

of post.<br />

• Assumes beam members are bevel cut at corner.<br />

Dimensions (in) Fastener Schedule 2,3<br />

Factored Resistance 1<br />

Post Beam<br />

DF-L (115%) S-P-F (115%)<br />

F1 F2 Uplift F1 F2 Uplift<br />

Post <strong>USP</strong><br />

Steel<br />

Size Stock No. Ref. No. Gauge W L Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN<br />

4 x 4 PBC44-TZ -- -- 18 4-15/16 6-1/2 8 16d HDG 8 16d HDG 900 4.00 900 4.00 1800 8.01 775 3.45 775 3.45 1555 6.92<br />

6 x 6 PBC66-TZ -- -- 18 6-15/16 6-1/2 8 16d HDG 8 16d HDG 900 4.00 900 4.00 1800 8.01 775 3.45 775 3.45 1555 6.92<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for<br />

other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

Typical PBC<br />

installation<br />

W<br />

PBC<br />

W<br />

L<br />

Composite Post Bases – CPB series<br />

The CPB is made of corrosion resistant composite material<br />

compatible with preservative treated lumber. Provides code<br />

required 1˝ stand-off and can be used with rough lumber sizes.<br />

Materials: High Strength composite<br />

Installation:<br />

• Attach base to post with (4) 10d HDG nails.<br />

• Attach post to concrete using 1/2˝ diameter rod into concrete and<br />

extend into wood member.<br />

• Not recommended for fence posts or other unrestrained (not<br />

fixed or fastened at top) applications. These anchors are not<br />

designed to resist overturning (moment) loads.<br />

Caps & Bases<br />

Typical CPB<br />

installation<br />

Dimensions (in) Bottom<br />

Fastener Schedule 5 Factored Concrete Bearing<br />

Surface<br />

Resistance 1,2 Strength 3,4<br />

Post <strong>USP</strong><br />

Bearing<br />

Size Stock No. Ref. No. W1 W2 Area Qty Type Lbs kN Lbs kN<br />

4 x 4 CPB44 CPS4 3-1/4 3-1/4 2.2 4 10d HDG 5235 23.29 6545 29.11<br />

4 x 6 CPB46 CPS46 3-5/16 5-5/16 3.3 4 10d HDG 6810 30.29 9820 43.68<br />

5 x 5 CPB55 CPS5 4-1/8 4-1/8 3.0 4 10d HDG 6295 28.00 8925 39.70<br />

6 x 6 CPB66 CPS6 5-5/16 5-5/16 3.9 4 10d HDG 8570 38.12 11600 51.60<br />

8 x 8 CPB88 CPS7 7-1/4 7-1/4 6.4 4 10d HDG 12490 55.56 19040 84.70<br />

1) Loads shall not be increased for short-term loading.<br />

2) Loads require a minimum 650 psi wood compressive strength.<br />

3) Concrete Design Bearing Strength = Ø (0.85 f' C A 1 ) with f' C = 2,500 psi. ACI 318-02, Section 10.17.1.<br />

4) Design Bearing Strength has been increased assuming (A 2 / A 1 ) 0.5 per ACI 318-02, Section 10.17.1.<br />

5) NAILS:<br />

W 1<br />

CPB<br />

W 2<br />

1˝<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 59<br />

<strong>USP</strong>2240-131


Column Caps – KCCQ & KECCQ series<br />

Designed to be installed without the need to drill bolt holes, simplifying installation and<br />

maintaining the wood cross section. Installs with WS Wood Screws offering high uplift<br />

capacity. The wood screws provide a lower profile than bolts.<br />

KCCQ – Standard column cap.<br />

KECCQ – End column cap.<br />

Materials: See chart<br />

Finish: <strong>USP</strong> primer<br />

Options: See Specialty Options on pages 62-63.<br />

KCCQ325-4, KCCQ325-6, KCCQ44, KCCQ46, KCCQ525-4,<br />

KCCQ525-6, KCCQ64,KCCQ66, KECCQ325-4, KECCQ325-6,<br />

KECCQ44, KECCQ46, KECCQ525-6, KECCQ64 & KECCQ66<br />

are available in Hot-dip galvanized. To order, add HDG to stock<br />

number, as in KCCQ44-HDG.<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• WS3 Wood Screws, 1/4˝ dia. x 3˝ long, are supplied with KCCQ and KECCQ<br />

Column Caps.<br />

• Beams shall be designed to support the required loads. Beam shear may limit<br />

loads to less than listed loads for device. A design professional shall determine<br />

the adequacy of the stud to resist published loads.<br />

W 1<br />

L<br />

H<br />

Typical KCCQ44<br />

centre cap<br />

installation<br />

W 1<br />

L<br />

W 2<br />

KCCQ44<br />

H<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Caps & Bases<br />

<strong>USP</strong><br />

Stock No.<br />

Dimensions (in)<br />

Fastener Schedule 4<br />

W 2<br />

KECCQ44<br />

Factored Resistance 3<br />

Typical KECCQ44<br />

end cap<br />

installation<br />

Column<br />

DF-L<br />

S-P-F<br />

Beam or Post Bearing Uplift Bearing Uplift<br />

(100%) 2 (115%) 1,8 (100%) 2 (115%) 1,8<br />

Steel<br />

Ref. No. Gauge W1 W2 H L Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN<br />

Centre Column Caps<br />

KCCQ325-4 CCQ3-4SDS2.5 7 3-1/4 3-5/8 6-1/2 11 16 WS3 14 WS3 30940 137.63 12920 57.47 21040 93.59 9170 40.79<br />

KCCQ325-6 CCQ3-6SDS2.5 7 3-1/4 5-1/2 6-1/2 11 16 WS3 14 WS3 30940 137.63 12920 57.47 21040 93.59 9170 40.79<br />

KCCQ44 CCQ44SDS2.5 7 3-5/8 3-5/8 6-1/2 11 16 WS3 14 WS3 34655 154.16 12575 55.94 23565 104.83 8930 40.79<br />

KCCQ45 -- -- 7 3-5/8 5-3/8 6-1/2 11 16 WS3 14 WS3 34655 154.16 12575 55.94 23565 104.83 8930 40.79<br />

KCCQ46 CCQ46SDS2.5 7 3-5/8 5-1/2 6-1/2 11 16 WS3 14 WS3 34655 154.16 12920 57.47 23565 104.83 9170 40.79<br />

KCCQ47 -- -- 7 3-5/8 7-1/8 6-1/2 11 16 WS3 14 WS3 34655 154.16 12575 55.94 23565 104.83 8930 40.79<br />

KCCQ47X -- -- 7 3-5/8 7-1/8 6-1/2 13 16 WS3 14 WS3 40955 182.18 12575 55.94 27850 123.89 8930 40.79<br />

KCCQ48 CCQ48SDS2.5 7 3-5/8 7-1/2 6-1/2 11 16 WS3 14 WS3 34655 154.16 12920 57.47 23565 104.83 9170 40.79<br />

KCCQ525-4 CCQ5-4SDS2.5 3 5-1/4 3-5/8 8 13 16 WS3 14 WS3 59960 266.73 12920 57.47 40775 181.38 9170 40.79<br />

KCCQ525-6 CCQ5-6SDS2.5 3 5-1/4 5-1/2 8 13 16 WS3 14 WS3 59960 266.73 12920 57.47 40775 181.38 9170 40.79<br />

KCCQ525-8 CCQ5-8SDS2.5 3 5-1/4 7-1/2 8 13 16 WS3 14 WS3 59960 266.73 12920 57.47 40775 181.38 9170 40.79<br />

KCCQ57 -- -- 7 5-3/8 7-1/8 6-1/2 11 16 WS3 14 WS3 51975 231.21 12920 57.47 35345 157.23 9170 40.79<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Bearing loads are based on compression perpendicular to grain values published in the 2001 NDS and soft converted to Limit States Design.<br />

3) Factored resistances are based on lumber with a specific gravity of DF-L = 0.49 and S-P-F = 0.42 and a moisture content of 19% or less.<br />

<br />

5) Beams shall be designed to support the required loads. Beam shear may limit loads to less than listed loads for device.<br />

6) The designer shall check post for required loads.<br />

7) Spliced conditions must be detailed by the specifier to transfer tension loads between spliced members by means other than the column cap.<br />

8) Uplift loads do not apply to splice conditions.<br />

continued on next page<br />

60<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Column Caps – KCCQ & KECCQ series continued<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• WS3 Wood Screws, 1/4˝ dia. x 3˝ long, are supplied with KCCQ and KECCQ Column<br />

Caps.<br />

• Beams shall be designed to support the required loads. Beam shear may limit loads to<br />

less than listed loads for device. A design professional shall determine the adequacy of<br />

the stud to resist published loads.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>USP</strong><br />

Stock No.<br />

Dimensions (in) Fastener Schedule 4<br />

KCCQ64 CCQ64SDS2.5 7 5-1/2 3-5/8 6-1/2 11 16 WS3 14 WS3 54455 242.24 12920 57.47 37030 164.72 9170 40.79<br />

KCCQ66 CCQ66SDS2.5 7 5-1/2 5-1/2 6-1/2 11 16 WS3 14 WS3 54455 242.24 12920 57.47 37030 164.72 9170 40.79<br />

KCCQ67X CCQ6-7.13SDS2.5 7 5-1/2 7-1/8 6-1/2 11 16 WS3 14 WS3 54455 242.24 12920 57.47 37030 164.72 9170 40.79<br />

KCCQ68 CCQ68SDS2.5 7 5-1/2 7-1/2 6-1/2 11 16 WS3 14 WS3 54455 242.24 12920 57.47 37030 164.72 9170 40.79<br />

KCCQ74 CCQ74SDS2.5 3 6-7/8 3-5/8 6-1/2 11 16 WS3 14 WS3 66825 297.26 12920 57.47 45440 202.14 9170 40.79<br />

KCCQ76 CCQ76SDS2.5 3 6-7/8 5-1/2 6-1/2 11 16 WS3 14 WS3 66825 297.26 12920 57.47 45440 202.14 9170 40.79<br />

KCCQ77 CCQ77SDS2.5 3 6-7/8 6-7/8 6-1/2 11 16 WS3 14 WS3 66825 297.26 12920 57.47 45440 202.14 9170 40.79<br />

KCCQ78 CCQ78SDS2.5 3 6-7/8 7-1/2 6-1/2 11 16 WS3 14 WS3 66825 297.26 12920 57.47 45440 202.14 9170 40.79<br />

KCCQ71-4 CCQ7.1-4SDS2.5 3 7-1/8 3-5/8 6-1/2 11 16 WS3 14 WS3 69300 308.27 12920 57.47 47125 209.63 9170 40.79<br />

KCCQ71-6 CCQ7.1-6SDS2.5 3 7-1/8 5-1/2 6-1/2 11 16 WS3 14 WS3 69300 308.27 12920 57.47 47125 209.63 9170 40.79<br />

KCCQ71-71 CCQ7.1-7.1SDS2.5 3 7-1/8 7-1/8 6-1/2 11 16 WS3 14 WS3 69300 308.27 12920 57.47 47125 209.63 9170 40.79<br />

KCCQ71-8 CCQ7.1-8SDS2.5 3 7-1/8 7-1/2 6-1/2 11 16 WS3 14 WS3 69300 308.27 12920 57.47 47125 209.63 9170 40.79<br />

KCCQ84 -- -- 7 7-1/2 3-5/8 6-1/2 11 16 WS3 14 WS3 74255 330.32 12920 57.47 50495 224.62 9170 40.79<br />

KCCQ86 CCQ86SDS2.5 7 7-1/2 5-1/2 6-1/2 11 16 WS3 14 WS3 74255 330.32 12920 57.47 50495 224.62 9170 40.79<br />

KCCQ88 CCQ88SDS2.5 7 7-1/2 7-1/2 6-1/2 11 16 WS3 14 WS3 74255 330.32 12920 57.47 50495 224.62 9170 40.79<br />

KCCQ94 -- -- 7 8-7/8 3-5/8 6-1/2 11 16 WS3 14 WS3 86625 385.34 12920 57.47 58905 262.03 9170 40.79<br />

KCCQ96 CCQ96SDS2.5 7 8-7/8 5-1/2 6-1/2 11 16 WS3 14 WS3 86625 385.34 12920 57.47 58905 262.03 9170 40.79<br />

KCCQ98 CCQ98SDS2.5 7 8-7/8 7-1/2 6-1/2 11 16 WS3 14 WS3 86625 385.34 12920 57.47 58905 262.03 9170 40.79<br />

KCCQ106 CCQ106SDS2.5 7 9-1/2 5-1/2 6-1/2 11 16 WS3 14 WS3 94055 418.39 12920 57.47 63960 284.52 9170 40.79<br />

End Column Caps<br />

Factored Resistance 3<br />

DF-L<br />

S-P-F<br />

Column<br />

Beam or Post Bearing Uplift Bearing Uplift<br />

(100%) 2 (115%) 1,8 (100%) 2 (115%) 1,8<br />

Steel<br />

Ref. No. Gauge W1 W2 H L Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN<br />

Centre Column Caps<br />

7 3-1/4 3-5/8 6-1/2 7-1/2 16 WS3 14 WS3 21095 93.84 11785 52.42 14340 63.79 8370 40.79<br />

7 3-1/4 5-1/2 6-1/2 7-1/2 16 WS3 14 WS3 21095 93.84 11785 52.42 14340 63.79 8370 40.79<br />

7 3-5/8 3-5/8 6-1/2 8-1/2 16 WS3 14 WS3 24430 108.67 13385 59.54 18210 81.01 9505 40.79<br />

-- -- 7 3-5/8 5-3/8 6-1/2 7-1/2 16 WS3 14 WS3 23625 105.09 13385 59.54 16065 71.46 9505 40.79<br />

7 3-5/8 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 26775 119.11 11785 52.42 18210 81.01 8370 40.79<br />

-- -- 7 3-5/8 7-1/8 6-1/2 9-1/2 16 WS3 14 WS3 29925 133.12 13385 59.54 20345 90.50 9505 40.79<br />

-- -- 7 3-5/8 7-1/8 6-1/2 9-1/2 16 WS3 14 WS3 29925 133.12 13385 59.54 20345 90.50 9505 40.79<br />

7 3-5/8 7-1/2 6-1/2 8-1/2 16 WS3 14 WS3 26775 119.11 11785 52.42 18210 81.01 8370 40.79<br />

3 5-1/4 3-5/8 8 9-1/2 16 WS3 14 WS3 32155 143.04 11785 52.42 24350 108.32 8370 40.79<br />

3 5-1/4 5-1/2 8 9-1/2 16 WS3 14 WS3 39310 174.87 11785 52.42 28985 128.94 8370 40.79<br />

3 5-1/4 7-1/2 8 9-1/2 16 WS3 14 WS3 43820 194.93 11785 52.42 29795 132.54 8370 40.79<br />

-- -- 7 5-3/8 7-1/8 6-1/2 9-1/2 16 WS3 14 WS3 40160 178.65 11785 52.42 27310 121.49 8370 40.79<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Bearing loads are based on compression perpendicular to grain values published in the 2001 NDS and soft converted to Limit States Design.<br />

3) Factored resistances are based on lumber with a specific gravity of DF-L = 0.49 and S-P-F = 0.42 and a moisture content of 19% or less.<br />

<br />

5) Beams shall be designed to support the required loads. Beam shear may limit loads to less than listed loads for device.<br />

6) The designer shall check post for required loads.<br />

7) Spliced conditions must be detailed by the specifier to transfer tension loads between spliced members by means other than the column cap.<br />

8) Uplift loads do no apply to splice conditions.<br />

Caps & Bases<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 61<br />

<strong>USP</strong>2240-131


Column Caps – KCCQ & KECCQ series continued<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• WS3 Wood Screws, 1/4˝ dia. x 3˝ long, are supplied with KCCQ and KECCQ Column<br />

Caps.<br />

• Beams shall be designed to support the required loads. Beam shear may limit loads to<br />

less than listed loads for device. A design professional shall determine the adequacy of<br />

the stud to resist published loads.<br />

Caps & Bases<br />

<strong>USP</strong><br />

Stock No.<br />

Dimensions (in) Fastener Schedule 4 Factored Resistance 3<br />

Column<br />

DF-L S-P-F<br />

Beam or Post Bearing Uplift Bearing Uplift<br />

(100%) 2 (115%) 1,8 (100%) 2 (115%) 1,8<br />

Steel<br />

Ref. No. Gauge W1 W2 H L Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN<br />

End Column Caps<br />

KECCQ64 ECCQ64SDS2.5 7 5-1/2 3-5/8 6-1/2 8-1/2 16 WS3 14 WS3 33890 150.76 11785 52.42 25605 113.90 8370 40.79<br />

KECCQ66 ECCQ66SDS2.5 7 5-1/2 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 41630 185.19 11785 52.42 28615 127.29 8370 40.79<br />

KECCQ67X ECCQ6-7.13SDS2.5 7 5-1/2 7-1/8 6-1/2 8-1/2 16 WS3 14 WS3 42075 187.17 11785 52.42 28615 127.29 8370 40.79<br />

KECCQ68 ECCQ68SDS2.5 7 5-1/2 7-1/2 6-1/2 8-1/2 16 WS3 14 WS3 42075 187.17 11785 52.42 28615 127.29 8370 40.79<br />

KECCQ74 ECCQ74SDS2.5 3 6-7/8 3-5/8 6-1/2 8-1/2 16 WS3 14 WS3 39550 175.93 11785 52.42 29665 131.96 8370 40.79<br />

KECCQ76 ECCQ76SDS2.5 3 6-7/8 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 51640 229.72 11785 52.42 35115 156.21 8370 40.79<br />

KECCQ77 ECCQ77SDS2.5 3 6-7/8 6-7/8 6-1/2 8-1/2 16 WS3 14 WS3 51640 229.72 11785 52.42 35115 156.21 8370 40.79<br />

KECCQ78 ECCQ78SDS2.5 3 6-7/8 7-1/2 6-1/2 8-1/2 16 WS3 14 WS3 51640 229.72 11785 52.42 35115 156.21 8370 40.79<br />

KECCQ71-4 ECCQ7.1-4SDS2.5 3 7-1/8 3-5/8 6-1/2 8-1/2 16 WS3 14 WS3 40665 180.89 11785 52.42 30455 135.48 8370 40.79<br />

KECCQ71-6 ECCQ7.1-6SDS2.5 3 7-1/8 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 50810 226.02 11785 52.42 36420 162.01 8370 40.79<br />

KECCQ71-71 ECCQ7.1-7.1SDS2.5 3 7-1/8 7-1/8 6-1/2 8-1/2 16 WS3 14 WS3 53555 238.23 11785 52.42 36420 162.01 8370 40.79<br />

KECCQ71-8 ECCQ7.1-8SDS2.5 3 7-1/8 7-1/2 6-1/2 8-1/2 16 WS3 14 WS3 53555 238.23 11785 52.42 36420 162.01 8370 40.79<br />

KECCQ84 -- -- 7 7-1/2 3-5/8 6-1/2 8-1/2 16 WS3 14 WS3 42890 190.79 11785 52.42 39015 173.55 8370 40.79<br />

KECCQ86 ECCQ86SDS2.5 7 7-1/2 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 53840 239.50 11785 52.42 39015 173.55 8370 40.79<br />

KECCQ88 ECCQ88SDS2.5 7 7-1/2 7-1/2 6-1/2 8-1/2 16 WS3 14 WS3 57375 255.23 11785 52.42 39015 173.55 8370 40.79<br />

KECCQ94 -- -- 7 8-7/8 3-5/8 6-1/2 8-1/2 16 WS3 14 WS3 48375 215.19 11785 52.42 35940 159.88 8370 40.79<br />

KECCQ96 ECCQ96SDS2.5 7 8-7/8 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 61385 273.06 11785 52.42 44395 197.49 8370 40.79<br />

KECCQ98 ECCQ98SDS2.5 7 8-7/8 7-1/2 6-1/2 8-1/2 16 WS3 14 WS3 66940 297.78 11785 52.42 45520 202.49 8370 40.79<br />

KECCQ106 ECCQ106SDS2.5 7 9-1/2 5-1/2 6-1/2 8-1/2 16 WS3 14 WS3 65895 293.13 11785 52.42 47520 211.39 8370 40.79<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Bearing loads are based on compression perpendicular to grain values published in the 2001 NDS and soft converted to Limit States Design.<br />

3) Factored resistances are based on lumber with a specific gravity of DF-L = 0.49 and S-P-F = 0.42 and a moisture content of 19% or less.<br />

<br />

5) Beams shall be designed to support the required loads. Beam shear may limit loads to less than listed loads for device.<br />

6) The designer shall check post for required loads.<br />

7) Spliced conditions must be detailed by the specifier to transfer tension loads between spliced members by means other than the column cap.<br />

8) Uplift loads do not apply to splice conditions.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Speciality Options:<br />

• For end column caps, add an E after the K in the stock number, as in KECCQ325-4.<br />

• Straps may be rotated 90° on special order where the W2 dimension is less than or equal to<br />

the W1 dimension.<br />

• KCCQO/KECCQO – Cap only, no strap design for field welding to pipe or other columns.<br />

• KCCQOB – For cross beam connections. Any two buckets can be welded together for a wide<br />

variety of applications. Allowable load shall be the lesser of the two components.<br />

• KCCQT – For T beam intersections, consult <strong>USP</strong>. Specify beam/column conditions,<br />

dimensions, and loading requirements.<br />

• KCCQC – For X beam intersections, consult <strong>USP</strong>. Specify beam/column conditions,<br />

dimensions, and loading requirements.<br />

• KECCQLL/R – For L beam intersections, consult <strong>USP</strong>. Specify left (L) or right (R) beam/column<br />

conditions, dimensions, and loading requirements.<br />

Dimension call-outs not shown in the table must be specified at time of ordering for<br />

specialty options, non-catalog, or rough/full size lumber sizes.<br />

continued on next page<br />

62<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Column Caps – KCCQ & KECCQ series continued<br />

4˝<br />

Typ.<br />

L<br />

L<br />

H 1<br />

W 3<br />

W 4<br />

H 2<br />

H 3<br />

H 1<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

W 1<br />

KCCQC<br />

W 2<br />

1/4˝ unless<br />

otherwise<br />

specified<br />

Optional KECCQ<br />

Rotated Straps 90°<br />

H 1<br />

W1<br />

L 2<br />

L 1<br />

W 2<br />

KCCQOB<br />

4˝ Typ.<br />

W2<br />

H 2<br />

KECCQLL<br />

left shown<br />

H2<br />

W 3<br />

H 1<br />

H<br />

W 1<br />

W 1<br />

KCCQO<br />

L<br />

H 2<br />

W 3<br />

W 2<br />

KCCQT<br />

Top View of Specialty Options Column Cap Configurations<br />

Caps & Bases<br />

KECCQLL<br />

rotated 90° left<br />

KECCQLR<br />

rotated 90° right<br />

left right KECCQ<br />

offset left<br />

KECCQ<br />

offset right<br />

KCCQ<br />

offset left<br />

KCCQ<br />

offset right<br />

KECCQ<br />

rotated 45° left<br />

KECCQ<br />

rotated 45° right<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 63<br />

<strong>USP</strong>2240-131


Angles & Straps<br />

Framing Plates & Angles . . . . . .Pages 66-70<br />

• MPA Series<br />

Multi-purpose framing angles.<br />

• MP Series<br />

Field adjustable framing angle.<br />

MPA1<br />

MP34<br />

MP<br />

MP_F<br />

• MP_F Series<br />

Multi-purpose framing plate.<br />

• RBC<br />

Field adjustable roof boundary clip.<br />

• A3 & AC Series<br />

Framing angles for joist support.<br />

• JA Series<br />

Heavier-capacity framing angle for joist support.<br />

Stud Plate Ties . . . . . . . . . . . . . . . . .Page 71<br />

• RSPT Series<br />

Flat stud to plate connector.<br />

• SPT & SPTH Series<br />

U-shaped stud to plate connector.<br />

RBC<br />

RSPT<br />

A3<br />

SPT22<br />

AC<br />

SPT<br />

JA1<br />

SPTH<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Lateral Joist <strong>Connectors</strong> . . . . . . . .Page 72<br />

• LJC-TZ<br />

Sill plate to floor joist connector.<br />

• LJQ Series<br />

Higher capacity sill plate to floor joist connector.<br />

LJC-TZ<br />

LJQ-TZ<br />

Miscellaneous . . . . . . . . . . . . .Pages 72-74<br />

• ANJ44S-HDG<br />

Heavy-capacity corner-framing angle.<br />

• B & BL Series<br />

L-shaped corner braces.<br />

ANJ44S-HDG<br />

B<br />

BL<br />

Angles & Straps<br />

• KHL Series<br />

Heavy-capacity corner framing angle.<br />

• L, LH, T & TH Series<br />

Medium-capacity L and T-shaped straps.<br />

• Ornamental Series<br />

<strong>Connectors</strong> with ornamental notching.<br />

KHL<br />

L/LH<br />

T/TH<br />

KHL33-O<br />

Framing Clips & Header <strong>Hangers</strong> . . . . .Page 75<br />

• SFC6 Series<br />

Light-capacity header framing clip.<br />

• HH Series<br />

Heavy-capacity header hanger.<br />

SFC<br />

HH<br />

continued on next page<br />

64<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Angles & Straps<br />

Coiled Strapping . . . . . . . . . . . . . . .Page 76<br />

• CMST & CMSTC Series<br />

3˝ wide coiled strapping.<br />

CMST/CMSTC<br />

• RS Series<br />

11⁄4˝ wide coiled strapping.<br />

RS<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Straps . . . . . . . . . . . . . . . . . . . .Pages 77-80<br />

• LSTA, MSTA, & ST Series<br />

11⁄4˝ wide flat strapping.<br />

• HRS Series<br />

13⁄ 8˝ or 31⁄ 4˝ wide flat strapping.<br />

• KST & KSTI Series<br />

21⁄16˝ wide flat strapping.<br />

• HTP Series<br />

3˝ wide flat strapping.<br />

• MSTC Series<br />

3˝ wide flat strapping.<br />

• LSTI<br />

33⁄4˝ wide flat strapping for open web trusses.<br />

LSTA/MSTA<br />

ST<br />

HRS<br />

KST<br />

KSTI<br />

HTP<br />

MSTC<br />

• KRPS Series<br />

Protection strap for pipes placed in partitions.<br />

LSTI<br />

• MSTCB Series<br />

Pre-bent strap.<br />

Twist Straps . . . . . . . . . . . . . . .Pages 81-82<br />

KRPS<br />

MSTCB<br />

• LFTA6<br />

Light-capacity twist strap.<br />

• LTW Series<br />

Light-capacity twist strap.<br />

• MTW Series<br />

Medium-capacity twist strap.<br />

• HTW Series<br />

Heavy-capacity twist strap.<br />

• KTS Series<br />

Medium-capacity angled twist strap.<br />

Permanent Wood Foundation<br />

Strap . . . . . . . . . . . . . . . . . . . . . . . . .Page 83<br />

• PWFS24<br />

Transfers ground lateral loads to floor diaphragm.<br />

LFTA6 LTW MTW/HTW KTS<br />

PWFS24<br />

Angles & Straps<br />

Masonry Straps . . . . . . . . . . .Pages 84-85<br />

• MSTAM Series<br />

1/4˝ wide flat strapping.<br />

• MSTCM Series<br />

3˝ wide flat strapping.<br />

• HTWM Series<br />

Heavy-capacity twist strap.<br />

MSTAM<br />

MSTCM<br />

HTWM<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 65<br />

<strong>USP</strong>2240-131


Multi-Purpose Framing Angles – MP34, MPA1 & MPF series<br />

MP34 – Framing angle without tabs.<br />

MPA1 – Tabs enable two and three-way connections.<br />

MP4F – Connects 2x framing with floor sheathing up to 5/8˝.<br />

MP6F – Connects 3x framing with floor sheathing up to 3/4˝. Better choice<br />

for connections where floor sheathing is between sole plate and rim board.<br />

Materials: See chart<br />

Finish: G90 galvanizing; MPA1-GC – Gold Coat<br />

Options: MPA1, MP34, and MP4F are available in Triple Zinc.<br />

To order, add TZ to stock number, as in MPA1-TZ.<br />

MPA1, MP34, and MP6F are available in Stainless Steel. To<br />

order, add SS to stock number, as in MPA1-SS.<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Bend tabs only once.<br />

• MP4F connects 2x framing with floor sheathing up to 5⁄8˝.<br />

• MP6F connects 3x framing with floor sheathing up to 3⁄4˝. Better choice for<br />

connections where floor sheathing is between sole plate and rim board.<br />

4 1 /2˝<br />

1 7 /16˝<br />

MPA1-GC<br />

1 1 /2˝<br />

2 13 /16˝<br />

1 1 /2˝<br />

1 1 /2˝<br />

1 7 /16˝<br />

MP34<br />

MPA1<br />

4 1 /2˝<br />

1 7 /16˝<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Figure 1 Figure 2 Figure 3<br />

F 1<br />

B 1<br />

A 1<br />

C 1<br />

B 2<br />

A 2<br />

C 2<br />

F 2<br />

F 1<br />

F 3<br />

Typical MPA1<br />

joist / header installation<br />

Typical MPA1<br />

rafter / plate installation<br />

Typical MPA1<br />

stud / plate installation<br />

Angles & Straps<br />

Figure 4<br />

F 2<br />

<strong>Hangers</strong><br />

F 3<br />

Typical MP34<br />

joist / header installation<br />

continued on next page<br />

66<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Multi-Purpose Framing Angles – MP34, MPA1 & MPF cont.<br />

MP6F<br />

MP4F<br />

Embossed plate lines<br />

Type 1<br />

V<br />

H<br />

MP4F = 3˝<br />

MP6F = 3 3 /4˝<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Embossed plate line<br />

guides placement<br />

<strong>USP</strong><br />

Stock No.<br />

MP4F<br />

Sheathing<br />

Typical MP_F<br />

installation<br />

Type 2<br />

Fastener Schedule 3,5,6<br />

Factored Resistance 1,3,4<br />

Steel Installation Header or Stud Joist or Plate Direction DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Ref. No. Gauge Type 2 Qty Type Qty Type of Load 2 100% 115% 100% 115% 100% 115% 100% 115%<br />

Figure 1<br />

6 8d x 1-1/2 6 8d x 1-1/2 F1 1115 1280 4.96 5.69 790 910 3.51 4.05<br />

6 8d x 1-1/2 6 8d x 1-1/2 F2 1300 1300 5.78 5.78 925 925 4.11 4.11<br />

6 8d x 1-1/2 3 8d x 1-1/2 A1 685 785 3.05 3.49 485 555 2.16 2.47<br />

Figure 2 6 8d x 1-1/2 3 8d x 1-1/2 B1 510 585 2.27 2.60 360 415 1.60 1.85<br />

6 8d x 1-1/2 3 8d x 1-1/2 C1 525 600 2.34 2.67 370 425 1.65 1.89<br />

6 8d x 1-1/2 6 8d x 1-1/2 A2 830 955 3.69 4.25 590 675 2.62 3.00<br />

Figure 3 6 8d x 1-1/2 6 8d x 1-1/2 B2 460 525 2.05 2.34 325 375 1.45 1.67<br />

6 8d x 1-1/2 6 8d x 1-1/2 C2 610 705 2.71 3.14 435 500 1.94 2.22<br />

Figure 1<br />

6 N8-GC 6 N8-GC F1 1115 1280 4.96 5.69 790 910 3.51 4.05<br />

6 N8-GC 6 N8-GC F2 1300 1300 5.78 5.78 925 925 4.11 4.11<br />

6 N8-GC 3 N8-GC A1 685 785 3.05 3.49 485 555 2.16 2.47<br />

Figure 2 6 N8-GC 3 N8-GC B1 510 585 2.27 2.60 360 415 1.60 1.85<br />

6 N8-GC 3 N8-GC C1 525 600 2.34 2.67 370 425 1.65 1.89<br />

6 N8-GC 6 N8-GC A2 830 955 3.69 4.25 590 675 2.62 3.00<br />

Figure 3 6 N8-GC 6 N8-GC B2 460 525 2.05 2.34 325 375 1.45 1.67<br />

6 N8-GC 6 N8-GC C2 610 705 2.71 3.14 435 500 1.94 2.22<br />

4 8d x 1-1/2 4 8d x 1-1/2 F1 855 985 3.80 4.38 610 700 2.71 3.11<br />

4 8d x 1-1/2 4 8d x 1-1/2 F2 1025 1025 4.56 4.56 725 725 3.23 3.23<br />

4 8d x 1-1/2 4 8d x 1-1/2 F3 555 635 2.47 2.82 395 450 1.76 2.00<br />

Type 1<br />

Type 2<br />

Type 1<br />

Type 2<br />

Type 1<br />

Type 2<br />

Type 1<br />

Type 2<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

8d x 1-1/2<br />

8d x 1-1/2<br />

8d<br />

8d<br />

8d x 1-1/2<br />

8d x 1-1/2<br />

8d<br />

8d<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

8d x 1-1/2<br />

8d x 1-1/2<br />

8d<br />

8d<br />

8d x 1-1/2<br />

8d x 1-1/2<br />

8d<br />

8d<br />

V<br />

V<br />

V<br />

V<br />

V<br />

V<br />

V<br />

V<br />

1380<br />

1380<br />

1380<br />

1380<br />

995<br />

995<br />

995<br />

995<br />

1585<br />

1585<br />

1585<br />

1585<br />

1145<br />

1145<br />

1145<br />

1145<br />

6.14<br />

6.14<br />

6.14<br />

6.14<br />

4.43<br />

4.43<br />

4.43<br />

4.43<br />

7.05<br />

7.05<br />

7.05<br />

7.05<br />

5.09<br />

5.09<br />

5.09<br />

5.09<br />

980<br />

980<br />

980<br />

980<br />

705<br />

705<br />

705<br />

705<br />

1125<br />

1125<br />

1125<br />

1125<br />

815<br />

815<br />

815<br />

815<br />

4.36<br />

4.36<br />

4.36<br />

4.36<br />

3.14<br />

3.14<br />

3.14<br />

3.14<br />

5.00<br />

5.00<br />

5.00<br />

5.00<br />

3.63<br />

3.63<br />

3.63<br />

3.63<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

8d x 1-1/2<br />

8d x 1-1/2<br />

8d<br />

8d<br />

8d x 1-1/2<br />

8d x 1-1/2<br />

8d<br />

8d<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

8d x 1-1/2<br />

8d x 1-1/2<br />

8d<br />

8d<br />

8d x 1-1/2<br />

8d x 1-1/2<br />

8d<br />

8d<br />

H<br />

H<br />

H<br />

H<br />

H<br />

H<br />

H<br />

H<br />

1380<br />

1380<br />

1380<br />

1380<br />

995<br />

995<br />

995<br />

995<br />

1585<br />

1585<br />

1585<br />

1585<br />

1145<br />

1145<br />

1145<br />

1145<br />

6.14<br />

6.14<br />

6.14<br />

6.14<br />

4.43<br />

4.43<br />

4.43<br />

4.43<br />

7.05<br />

7.05<br />

7.05<br />

7.05<br />

5.09<br />

5.09<br />

5.09<br />

5.09<br />

980<br />

980<br />

980<br />

980<br />

705<br />

705<br />

705<br />

705<br />

1125<br />

1125<br />

1125<br />

1125<br />

815<br />

815<br />

815<br />

815<br />

4.36<br />

4.36<br />

4.36<br />

4.36<br />

3.14<br />

3.14<br />

3.14<br />

3.14<br />

5.00<br />

5.00<br />

5.00<br />

5.00<br />

3.63<br />

3.63<br />

3.63<br />

3.63<br />

MPA1 A35 18<br />

MPA1-GC -- -- 18<br />

MP34 A34 18 Figure 4<br />

MP4F LTP4 20<br />

MP6F LTP5 20<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Refer to drawings for installation type and definition of the various load directions.<br />

3) If installing MP4F or MP6F over plywood, use 8d common nails for 100% of table load.<br />

4) Factored resistances are shown per angle. When using a single anchor, joist must be constrained from rotation.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ).<br />

6) NAILS:<br />

4 1 /4˝<br />

MP_F<br />

MP4F = 1˝<br />

MP6F = 1 3 /4˝<br />

Angles & Straps<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 67<br />

<strong>USP</strong>2240-131


Roof Boundary Clip – RBC<br />

Framing plate designed to connect roof<br />

blocking to a wall top plate.<br />

Materials: 20 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived<br />

from data submitted to<br />

various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners.See<br />

Product Notes, page 10.<br />

• Field adjustable from 0º to 90º.<br />

• Bend angle only once.<br />

Typical RBC<br />

Top-Plate to Outside of Blocking<br />

installation<br />

Typical RBC<br />

Top-Plate to Inside of Blocking<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Typical RBC<br />

Concrete Blockwall to Blocking<br />

installation<br />

Typical RBC<br />

1˝ foamboard installation<br />

H<br />

W<br />

Angles & Straps<br />

RBC<br />

Dimensions (in)<br />

Fastener Schedule 2,3,4<br />

Factored Resistance 1<br />

Top Plate Blocking<br />

F1 (115%)<br />

DF-L S-P-F<br />

<strong>USP</strong><br />

Steel<br />

Installation<br />

Stock No. Ref. No. Gauge W H Type Qty Type 2 Qty Type 2 Lbs kN Lbs kN<br />

Wood to Wood 6 10d x 1-1/2 6 10d x 1-1/2 990 4.40 615 2.74<br />

RBC RBC 20 4-1/4 6<br />

Wood to CMU 3 1/4" Tapcon 6 10d x 1-1/2 735 3.27 525 2.34<br />

1) Loads shown are for a single roof boundary clip.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

<br />

4) NAILS: 10d x 1-1/2 nails are 0.148" diameter by 1-1/2" long.<br />

New products or updated product information are designated in red font.<br />

68<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Framing Angles – A3, AC, JA, & MP series<br />

MP – 18 gauge. Field adjustable from 0° to 135°.<br />

A3 – 18 gauge. Eliminates toenailing and increases strength.<br />

AC – 16 gauge. Features staggered nail patterns which reduces wood<br />

splitting and allows installation on both sides of the supported member.<br />

JA – 14 or 16 gauge. Heavier capacity framing angle for joist support.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: See chart<br />

Finish: G90 galvanizing; AC7-GC, MP7-GC,<br />

& MP9-GC – Gold Coat<br />

Options: MP3, MP5, MP7, MP9, A3, AC5, AC7, AC9, & JA1<br />

are available Triple Zinc. To order, add TZ to stock<br />

number, as in MP5-TZ.<br />

MP5 and MP7 are available in Stainless Steel. To order,<br />

add SS to stock number, as in MP7-SS.<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Adjust<br />

0˚ to 135˚<br />

Typical MP<br />

installation<br />

Load<br />

direction<br />

2 1 /4˝<br />

2 1 /4˝<br />

L<br />

Typical JA1<br />

installation<br />

Typical MP<br />

Rafter Support<br />

MP<br />

F 2<br />

F 1<br />

Typical JA7<br />

installation<br />

W 1<br />

W 2<br />

L<br />

W 1<br />

W2<br />

Typical AC<br />

installation<br />

W 2<br />

W 1<br />

Angles & Straps<br />

F1<br />

F2<br />

L<br />

L<br />

JA3<br />

A3<br />

AC<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 69<br />

<strong>USP</strong>2240-131


Framing Angles – A3, AC, JA, & MP series continued<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• MP Framing Angles are fabricated at 100° and may be field<br />

adjusted by hand from 0° to 135°. Bend angle only once.<br />

Dimensions (in)<br />

Fastener Schedule 1,3,4<br />

Factored Resistance 2<br />

<strong>USP</strong><br />

Steel<br />

Header<br />

Joist Direction DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Stock No. Ref. No. Gauge W1 W2 L Qty Type Qty Type of Load 100% 115% 100% 115% 100% 115% 100% 115%<br />

A23, GA1,<br />

F1 970 1115 4.31 4.96 690 792 3.07 3.52<br />

A3 GA2, L30, 18 1-7/16 1-7/16 2-3/4 4 10d x 1-1/2 4 10d x 1-1/2<br />

S/A23<br />

F2 985 1130 4.38 5.03 700 802 3.11 3.57<br />

MP3 LS30 18 2-1/4 2-1/4 3-3/8 3 10d 3 10d F1 750 860 3.34 3.83 535 615 2.38 2.74<br />

MP5<br />

LS50,<br />

S/LS50<br />

18 2-1/4 2-1/4 4-5/8 4 10d 4 10d F1 1335 1535 5.94 6.83 950 1095 4.23 4.87<br />

MP7<br />

LS70,<br />

5 10d 5 10d<br />

S/LS70 18 2-1/4 2-1/4 5-7/8<br />

F1<br />

1740 2005 7.74 8.92 1235 1420 5.49 6.32<br />

MP7-GC -- -- 5 N10C-GC 5 N10C-GC 1740 2005 7.74 8.92 1235 1420 5.49 6.32<br />

MP9 LS90 6 10d 6 10d 1980 2280 8.81 10.14 1405 1615 6.25 7.18<br />

18 2-1/4 2-1/4 6-7/8 F1<br />

MP9-GC -- -- 6 N10C-GC 6 N10C-GC 1980 2280 8.81 10.14 1405 1615 6.25 7.18<br />

AC5<br />

AC7<br />

L50<br />

L70<br />

16<br />

16<br />

1-5/16<br />

1-5/16<br />

2-3/8<br />

2-3/8<br />

4-7/8<br />

6-15/16<br />

3<br />

4<br />

10d<br />

10d<br />

3<br />

4<br />

10d<br />

10d<br />

F1<br />

F1<br />

995<br />

1120<br />

1145<br />

1285<br />

4.43<br />

4.98<br />

5.09<br />

5.72<br />

705<br />

795<br />

815<br />

910<br />

3.14<br />

3.54<br />

3.63<br />

4.05<br />

F2<br />

F2<br />

930<br />

1335<br />

1070<br />

1535<br />

4.14<br />

5.94<br />

4.76<br />

6.83<br />

660<br />

950<br />

760<br />

1090<br />

2.94<br />

4.23<br />

3.38<br />

4.85<br />

AC7-GC -- -- 16 1-5/16 2-3/8 6-15/16 4 N10C-GC 4 N10C-GC<br />

F1 1120 1285 4.98 5.72 795 910 3.54 4.05<br />

F2 1335 1535 5.94 6.83 950 1090 4.23 4.85<br />

AC9<br />

JA1<br />

JA3<br />

JA5<br />

JA7<br />

JA9<br />

L90<br />

A21<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

16<br />

16<br />

14<br />

14<br />

14<br />

14<br />

1-5/16<br />

1-1/2<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

2-3/8<br />

1-1/2<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

8-7/8<br />

1-1/4<br />

3<br />

5<br />

7<br />

9<br />

5<br />

2<br />

4<br />

6<br />

8<br />

10<br />

10d<br />

10d x 1-1/2<br />

16d<br />

16d<br />

16d<br />

16d<br />

5<br />

2<br />

4<br />

6<br />

8<br />

10<br />

10d<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

F1<br />

F1<br />

F1<br />

F1<br />

F1<br />

F1<br />

1860<br />

421<br />

963<br />

1556<br />

3058<br />

3767<br />

2135<br />

484<br />

1108<br />

1790<br />

3517<br />

4333<br />

8.27<br />

1.87<br />

4.28<br />

6.92<br />

13.60<br />

16.76<br />

9.50<br />

2.15<br />

4.93<br />

7.96<br />

15.64<br />

19.27<br />

1320<br />

299<br />

684<br />

1105<br />

2171<br />

2675<br />

1515<br />

344<br />

786<br />

1271<br />

2497<br />

3076<br />

5.87<br />

1.33<br />

3.04<br />

4.91<br />

9.66<br />

11.90<br />

6.74<br />

1.53<br />

3.50<br />

5.65<br />

11.11<br />

13.68<br />

F2<br />

F2<br />

F2<br />

F2<br />

F2<br />

F2<br />

1335<br />

562<br />

874<br />

1665<br />

2664<br />

2697<br />

1535<br />

647<br />

1005<br />

1915<br />

3064<br />

3102<br />

5.94<br />

2.50<br />

3.89<br />

7.41<br />

11.85<br />

12.00<br />

6.83<br />

2.88<br />

4.47<br />

8.52<br />

13.63<br />

13.80<br />

950<br />

399<br />

620<br />

1182<br />

1892<br />

1915<br />

1090<br />

459<br />

713<br />

1360<br />

2176<br />

2202<br />

4.23<br />

1.78<br />

2.76<br />

5.26<br />

8.42<br />

8.52<br />

4.85<br />

2.04<br />

3.17<br />

6.05<br />

9.68<br />

9.80<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) Factored resistances are shown per angle, and may be doubled if installed in pairs. When using a single angle, joist must be constrained from rotation.<br />

<br />

4) NAILS:<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Angles & Straps<br />

70<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Stud Plate Ties – RSPT, SPT, & SPTH series<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

RSPT – 18 or 20 gauge. Connects stud to single or double plates.<br />

SPT – 20 gauge. Ties single and double plates to studs.<br />

F 1<br />

Uplift<br />

Size Stock No. 3 Ref. No. Gauge W H L Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN<br />

SPTH – Heavier 18 gauge version of SPT.<br />

SPTHW – 18 gauge. Attaches plate to studs over 1/2˝ sheathing.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Options: RSPT6, RSPT6-2, SPT4, SPT6, SPT8, SPT22,<br />

SPT24, SPTH4, SPTH6 and SPTH8 are<br />

available in Triple Zinc. To order, add TZ to<br />

stock number, as in SPTH4-TZ.<br />

Codes: Load values are derived from data submitted to Typical SPT4 Typical SPT24<br />

various North American building code installation<br />

installation<br />

evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

L<br />

H<br />

H<br />

H<br />

H<br />

W<br />

W<br />

W<br />

1 1 /4˝<br />

W<br />

RSPT6<br />

Nailing concentrated on<br />

top plate for greater<br />

RSPT6-2<br />

SPT<br />

SPT22<br />

resistance<br />

Reinforcement<br />

Locator<br />

F tab<br />

2<br />

ribs<br />

W<br />

H<br />

F 1<br />

Uplift<br />

L<br />

W<br />

1 1 /4˝<br />

Typical RSPT4 double<br />

plate installation<br />

Typical RSPT4 single<br />

plate installation<br />

RSPT4<br />

SPTH<br />

SPTHW similar<br />

Dimensions (in)<br />

Fastener Schedule 2,4<br />

Factored Resistance (115%) 1<br />

Stud<br />

Plate<br />

DF-L<br />

S-P-F<br />

Stud <strong>USP</strong><br />

Steel<br />

F1 F2 Uplift F1 F2 Uplift<br />

2x SPT22 SP1 20 1-9/16 4-3/8 3-1/2 4 10d 4 10d 695 3.09 325 1.45 755 3.36 600 2.67 280 1.25 650 2.89<br />

2x SPT24 SP2 20 1-9/16 5-5/8 3-1/2 6 10d 6 10d 695 3.09 325 1.45 1125 5.00 600 2.67 280 1.25 970 4.31<br />

4x SPT44 -- -- 20 3-9/16 6-3/4 6-1/2 6 16d 6 16d 845 3.76 310 1.38 1355 6.03 725 3.23 265 1.18 1165 5.18<br />

2x RSPT4 RSP4 20 1-1/2 4-1/8 -- -- 4 8d x 1-1/2 4 8d x 1-1/2 285 1.27 315 1.40 585 2.60 245 1.09 270 1.20 505 2.25<br />

2x RSPT6 SSP 18 1-1/2 5-7/16 -- -- 4 10d x 1-1/2 4 10d x 1-1/2 -- -- -- -- -- -- -- -- 740 3.29 -- -- -- -- -- -- -- -- 635 2.82<br />

(2) 2x RSPT6-2 DSP 18 2-3/4 5-7/16 -- -- 8 10d x 1-1/2 6 10d x 1-1/2 -- -- -- -- -- -- -- -- 1115 4.96 -- -- -- -- -- -- -- -- 960 4.27<br />

4x SPT4 SP4 20 3-9/16 6-7/8 -- -- 6 10d x 1-1/2 -- -- -- -- -- -- -- -- -- -- -- -- 960 4.27 -- -- -- -- -- -- -- -- 825 3.67<br />

6x SPT6 SP6 20 5-9/16 7-5/8 -- -- 6 10d x 1-1/2 -- -- -- -- -- -- -- -- -- -- -- -- 960 4.27 -- -- -- -- -- -- -- -- 825 3.67<br />

8x SPT8 SP8 20 7-5/16 8-1/2 -- -- 6 10d x 1-1/2 -- -- -- -- -- -- -- -- -- -- -- -- 960 4.27 -- -- -- -- -- -- -- -- 825 3.67<br />

4x<br />

6x<br />

SPTH4<br />

SPTH6<br />

SPH4<br />

SPH6<br />

18<br />

18<br />

3-9/16<br />

5-9/16<br />

8-5/8<br />

9-3/8<br />

-- --<br />

-- --<br />

12<br />

12<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

1275<br />

1275<br />

5.67<br />

5.67<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

1095<br />

1095<br />

4.87<br />

4.87<br />

SPTHW4<br />

SPTHW6<br />

SPH4R<br />

SPH6R<br />

18<br />

18<br />

4-1/16<br />

6-1/16<br />

8-3/8<br />

9-1/8<br />

-- --<br />

-- --<br />

12<br />

12<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

1275<br />

1275<br />

5.67<br />

5.67<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

1095<br />

1095<br />

4.87<br />

4.87<br />

8x SPTH8 SPH8 18 7-5/16 8-1/2 -- -- 12 10d x 1-1/2 -- -- -- -- -- -- -- -- -- -- -- -- 1275 5.67 -- -- -- -- -- -- -- -- 1095 4.87<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) SPT22, SPT24, and SPT44: the two nails fastened to the wide face of the stud must be driven 30° from the perpendicular on the horizontal plane.<br />

4) NAILS:<br />

Angles & Straps<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 71<br />

<strong>USP</strong>2240-131


Lateral Joist <strong>Connectors</strong> – LJC-TZ & LJQ-TZ series<br />

The LJC-TZ and LJQ-TZ Lateral Joist <strong>Connectors</strong> transfer lateral loads at the top foundation to the floor joists. The fastening<br />

patterns meet I-joist manufacturer recommendations.<br />

LJC-TZ – fastens the top side of the sill plate to the underside of the floor joist preventing splitting of the bottom chord flanges,<br />

and can be installed after the floor system has been installed. The product is load rated for use with dimension lumber floor<br />

joists as well as I-joist. It can also be used with cantilevered floor joists.<br />

LJQ-TZ – is a higher capacity connector designed for higher loads. It is similar in design to a joist hanger with a seat for the<br />

floor joist to bear against and utilizes wood screws to fasten to the sill plate. <strong>USP</strong>’s WS15-GC Wood Screws (included) provide<br />

quick installation without the need to pre-drill holes.<br />

Materials: See chart<br />

Finish: G-185 galvanizing<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• LJC-TZ – Installs after the floor joist has been placed with a minimum of (12) 8d x 1-1/2˝ HDG nails.<br />

• LJQ-TZ – Installs with (4) <strong>USP</strong> WS15-GC Wood Screws. WS15-GC Wood Screws are 1/4˝ diameter x 1-1/2˝ long and are<br />

included with LJQ-TZ connectors.<br />

3 3 /16˝<br />

D<br />

W<br />

L<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Typical LJC-TZ installation<br />

L<br />

1 /2˝<br />

LJC-TZ Typical LJQ-TZ installation LJQ-TZ<br />

Dimensions (in) Fastener<br />

Factored Resistance (100%)<br />

Schedule 1,2,3<br />

DF-L<br />

S-P-F<br />

<strong>USP</strong><br />

Steel<br />

2x I-Joist 2x I-Joist<br />

Stock No. Ref. No. Gauge W L D Qty Type Lbs kN Lbs kN Lbs kN Lbs kN<br />

LJC-TZ -- -- 18 3-3/16 8 -- -- 12 8d x 1-1/2 HDG 1310 5.83 1310 5.83 930 4.14 930 4.14<br />

LJQ15-TZ -- -- 16 1-9/16 3 1-1/2 4 WS15-GC 1880 8.36 1880 8.36 1335 5.94 1335 5.94<br />

LJQ17-TZ -- -- 16 1-13/16 3 1-1/2 4 WS15-GC 1880 8.36 1880 8.36 1335 5.94 1335 5.94<br />

LJQ20-TZ -- -- 16 2-1/8 3 1-1/2 4 WS15-GC 1880 8.36 1880 8.36 1335 5.94 1335 5.94<br />

LJQ23-TZ -- -- 16 2-5/16 3 1-1/2 4 WS15-GC 1880 8.36 1880 8.36 1335 5.94 1335 5.94<br />

LJQ25-TZ -- -- 16 2-9/16 3 1-1/2 4 WS15-GC 1880 8.36 1880 8.36 1335 5.94 1335 5.94<br />

LJQ35-TZ -- -- 16 3-9/16 3 1-1/2 4 WS15-GC 2205 9.81 2205 9.81 1565 6.96 1565 6.96<br />

<br />

<br />

3) NAILS:<br />

Heavy Angles – ANJ44S-HDG<br />

Angles & Straps<br />

Materials: 7 gauge<br />

Finish: Hot-dip galvanized<br />

Installation:<br />

• Install with (2) 1/2˝ x 2˝ lag screws into each leg.<br />

4˝<br />

4˝<br />

3 1 /2˝<br />

ANJ44S-HDG<br />

Dimensions (in)<br />

<strong>USP</strong><br />

Steel<br />

Lag<br />

Lag<br />

Stock No. Ref. No. Gauge W H L Qty Screw Qty Screw Lbs kN Lbs kN<br />

ANJ44S-HDG -- -- 7 3-1/2 4 4 2 2 845 3.76 600 2.67<br />

1) Bolts shall conform to ASTM A 307 or better.<br />

Fastener Schedule 1<br />

Header<br />

Joist<br />

Factored Resistance<br />

DF-L<br />

F1<br />

115%<br />

S-P-F<br />

F1<br />

115%<br />

F1<br />

Typical ANJ44S-HDG<br />

installation<br />

72<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Corner Reinforcements – B & BL series<br />

These multi-purpose braces are designed to provide<br />

reinforcement for 90° wood-to-wood connections.<br />

Materials: 12 gauge<br />

Finish: G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

Typical B66<br />

installation<br />

B66<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Dimensions (in) Fastener Schedule<br />

<strong>USP</strong><br />

Steel<br />

Nails 1,3 Bolts 2<br />

Stock No. Ref. No. Gauge W L Qty Type Qty Dia.<br />

B23 -- -- 12 2 2-5/8 6 16d -- -- -- --<br />

B24 -- -- 12 2 3-5/8 8 16d -- -- -- --<br />

BL3 A33 12 1-1/4 3-1/16 8 16d -- -- -- --<br />

BL4 A44 12 1-1/4 4-13/16 10 16d -- -- -- --<br />

BL6 -- -- 12 1-1/4 6-9/16 12 16d -- -- -- --<br />

BL8 -- -- 12 1-1/4 8-5/16 14 16d -- -- -- --<br />

B66 A66 12 1-1/2 6 -- -- -- -- 4 3/8<br />

B88 A88 12 2 8 -- -- -- -- 6 3/8<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) Bolts shall conform to ASTM A 307 or better.<br />

3) NAILS:<br />

Some model<br />

designs may<br />

vary from<br />

illustration<br />

shown<br />

W<br />

B23<br />

L<br />

L<br />

W<br />

BL4<br />

L<br />

L<br />

Corner Framing Angle - KHL series<br />

Designed for heavy-duty reinforcement of 90º framing intersections.<br />

Materials: See chart<br />

Finish: <strong>USP</strong> primer<br />

Options: KHL33, KHL35, KHL37, KHL43, KHL46, KHL55, KHL57 and<br />

KHL76 are available in Hot-dip galvanized. To order, add HDG<br />

to stock number, as in KHL35-HDG.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• <strong>Connectors</strong> are not load rated.<br />

NEW<br />

SIZES<br />

D 2<br />

D 1<br />

W 2<br />

D 4<br />

D 3 W 1<br />

KHL55<br />

Dimensions (in)<br />

Fastener Schedule<br />

<strong>USP</strong><br />

Steel<br />

Bolts 1 Gussets<br />

Stock No. Ref. No. Gauge W1 W2 L D1 D2 D3 D4 Qty Dia. Qty<br />

KHL33 HL33 7 3-1/4 3-1/4 2-1/2 1-1/4 -- -- 2 -- -- 2 5/8 -- --<br />

KHL35 HL35 7 3-1/4 3-1/4 5 1-1/4 2-1/2 2 -- -- 4 5/8 -- --<br />

KHL35G HL35G 7 3-1/4 3-1/4 5 1-1/4 2-1/2 2 -- -- 4 5/8 1<br />

KHL37 HL37 7 3-1/4 3-1/4 7-1/2 1-1/4 2-1/2 2 -- -- 6 5/8 -- --<br />

KHL335 SPECANGLE 3 3-1/2 5-1/4 3-1/2 -- -- -- -- -- -- -- -- 4 1/2 -- --<br />

KHL43 HL43 3 4-1/4 4-1/4 3 1-1/2 -- -- 2-3/4 -- -- 2 3/4 -- --<br />

KHL46 HL46 3 4-1/4 4-1/4 6 1-1/2 3 2-3/4 -- -- 4 3/4 -- --<br />

KHL49 HL49 3 4-1/4 4-1/4 9 1-1/2 3 2-3/4 -- -- 6 3/4 -- --<br />

KHL53 HL53 7 5-3/4 5-3/4 2-1/2 1-1/4 -- -- 2 2-1/2 4 5/8 -- --<br />

KHL55 HL55 7 5-3/4 5-3/4 5 1-1/4 2-1/2 2 2-1/2 8 5/8 -- --<br />

KHL57 HL57 7 5-3/4 5-3/4 7-1/2 1-1/4 2-1/2 2 2-1/2 12 5/8 -- --<br />

KHL73 HL73 3 7-1/4 7-1/4 3 1-1/2 -- -- 2-3/4 3 4 3/4 -- --<br />

KHL76 HL76 3 7-1/4 7-1/4 6 1-1/2 3 2-3/4 3 8 3/4 -- --<br />

KHL79 HL79 3 7-1/4 7-1/4 9 1-1/2 3 2-3/4 3 12 3/4 -- --<br />

1) All bolts shall meet or exceed the specifications of ASTM A 307.<br />

New products or updated product information are designated in red font.<br />

Typical KHL35<br />

installation<br />

gusset<br />

Angles & Straps<br />

KHL35G<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 73<br />

<strong>USP</strong>2240-131


L & T Straps – L, LH, T & TH series<br />

L & T – 14 gauge medium-capacity straps fasten with either nails or bolts.<br />

LH & TH – 7 gauge heavy-capacity bolt on strap.<br />

Materials: 14 gauge<br />

Finish: G90 galvanizing; TH12-HDG – Hot-dip galvanized<br />

Options: L6 and T6 are available in Triple Zinc. To order, add<br />

TZ to stock number, as in L6-TZ.<br />

LH12 is available in Hot-dip galvanized. To order, add<br />

HDG to stock number, as in LH12-HDG.<br />

H<br />

L<br />

W<br />

H<br />

L<br />

W<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Straps are not load rated.<br />

Dimensions (in)<br />

<strong>USP</strong><br />

Steel<br />

Bolts 2 Nails 1,3<br />

Stock No. Ref. No. Gauge W H L Qty Dia. Qty Type<br />

T6 66T 14 1-1/2 5 6 3 1/2 12 16d<br />

T8 -- -- 14 2 8 8-1/2 3 1/2 12 16d<br />

T12 128T 14 2 8 12 3 1/2 12 16d<br />

T1212 1212T 14 2 12 12 3 1/2 12 16d<br />

L6 66L 14 1-1/2 6 6 2 1/2 8 16d<br />

L8 88L 14 2 8 8 2 1/2 8 16d<br />

L12 1212L 14 2 12 12 4 1/2 12 16d<br />

TH12-HDG<br />

1212HT,<br />

1212HTHDG<br />

7 2-1/2 12 12 6 5/8 -- -- -- --<br />

TH16 1616HT 7 2-1/2 16 16-1/4 6 5/8 -- -- -- --<br />

LH12 1212HL 7 3 12 12 5 5/8 -- -- -- --<br />

LH16 1616HL 7 2-1/2 16 16 7 5/8 -- -- -- --<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) All bolts shall meet or exceed the specifications of ASTM A 307.<br />

3) NAILS:<br />

red font.<br />

Fastener Schedule<br />

TH16<br />

T6<br />

L6<br />

LH12<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Ornamental series<br />

Ornamental notching provides architectural appearance for<br />

exposed applications.<br />

Angles & Straps<br />

Materials: See chart<br />

Finish: <strong>USP</strong> primer<br />

Dimensions (in) Bolt Schedule 1 <strong>USP</strong><br />

Steel<br />

designs may<br />

H W<br />

3 1 /4˝<br />

L<br />

2 1 /2˝<br />

KHL33-O<br />

L<br />

L<br />

W<br />

Some model<br />

Stock No. Ref. No. Gauge Description W H L Qty Dia.<br />

vary from<br />

KHL33-O OHA33 7 Heavy Angle 3-1/4 -- -- 2-1/2 2 5/8<br />

illustration<br />

H<br />

KHL36-O OHA36 7 Heavy Angle 3-1/4 -- -- 6 4 5/8<br />

shown<br />

KHST64-O OHS135 7 Strap Tie 6 -- -- 13-1/2 4 3/4<br />

ST12-O OS 12 Strap Tie 2 -- -- 12 4 1/2<br />

L12-O OL 12 'L' Strap 2-1/2 11-7/8 11-7/8 5 1/2<br />

LH12-O OHL 7 'L' Strap 2-1/2 11-7/8 11-7/8 5 5/8<br />

T<br />

T1212-O OT 12 'T' Strap 2-1/2 11-7/8 14-1/2 6 1/2<br />

TH12-O OHT 7 'T' Strap 2-1/2 11-7/8 11-1/8 4 5/8<br />

TH16-O -- -- 7 'T' Strap 2-1/2 11-7/8 16-1/8 6 5/8<br />

1) All bolts shall meet or exceed the specifications of ASTM A 307.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• <strong>Connectors</strong> are not load rated.<br />

3 1 /4˝<br />

74<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Framing Clips - SFC6<br />

Framing clips replace end cripples under window sills.<br />

Materials: 16 gauge<br />

Finish: G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

F1<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Dimensions (in) Fastener Schedule 1,2<br />

Factored Resistance<br />

Header Joist<br />

DF-L<br />

S-P-F<br />

F1 Uplift F1<br />

<strong>USP</strong><br />

Steel<br />

Uplift<br />

Stock No. Ref. No. Gauge W H D Qty Type Qty Type 100% 115% 115% 100% 115% 115%<br />

SFC6 FC6 16 5-1/2 2-1/2 2-1/2 5 16d 5 16d 995 1145 775 835 960 650<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) NAILS:<br />

red font.<br />

H<br />

Uplift<br />

Typical SFC6<br />

installation<br />

W<br />

D<br />

SFC6<br />

Header <strong>Hangers</strong> - HH series<br />

Header <strong>Hangers</strong> support headers in door and window framing. Helps to<br />

eliminate cracks in drywall, plaster, or stucco over windows and doors.<br />

These products also provide anchorage and support for heavy fence rails,<br />

struts, or gate post cross brackets.<br />

F 3<br />

Materials: 16 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

H<br />

3 3 /4˝<br />

W<br />

HH66<br />

Fastener Schedule 1,2 Dimensions (in)<br />

Factored Resistance<br />

Header Stud<br />

DF-L<br />

S-P-F<br />

<strong>USP</strong><br />

Steel<br />

F1 (100%) F2 (115%) F3 (115%) F1 (100%) F2 (115%) F3 (115%)<br />

Stock No. Ref. No. Gauge W H Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN<br />

HH44 HH4 16 3-9/16 3-1/4 4 16d 9 16d 1785 7.94 915 4.07 850 3.78 1500 6.67 590 2.62 715 3.18<br />

HH66 HH6 16 5-1/2 5-1/4 6 16d 12 16d 2385 10.61 1365 6.07 1365 6.07 2000 8.90 885 3.94 1150 5.12<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) NAILS:<br />

2˝<br />

F 2<br />

F 1<br />

Typical HH44<br />

installation<br />

Angles & Straps<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 75<br />

<strong>USP</strong>2240-131


Coiled Strapping – CMST series, CMSTC16, & RS series<br />

Angles & Straps<br />

76<br />

Coiled strapping enables cut-to-length convenience<br />

for a variety of immediate job site needs.<br />

CMST – 3˝ wide strapping features diamond nail<br />

holes to provide nailing options and reduce wood<br />

splitting.<br />

CMSTC – 3˝ wide strapping is designed for high load<br />

conditions. Engineered to reduce wood splitting.<br />

RS – 11⁄4˝ wide strapping packaged in cartons<br />

containing 25-foot or longer coils.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Options: RS150 is available in Triple Zinc. To<br />

order, add TZ to stock number, as<br />

in RS150-TZ.<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes,<br />

page 10.<br />

• For safety, always wear gloves when handling or<br />

cutting coiled strapping.<br />

• CMST installations: Install to a minimum 2 ply 2x<br />

edge. Increase nail spacing if wood begins to split.<br />

• Designer may specify alternate nailing schedules. Refer<br />

to Nail Specification table on page 14 for nail shear<br />

values. Load values shall not exceed published factored<br />

resistance.<br />

Optional nails<br />

(wood shrinkage<br />

may occur and<br />

cause strap to<br />

buckle outward)<br />

Rim Joist Installation Fastener<br />

Factored Resistance<br />

Schedule 2,3,4,5<br />

Allowable Tension 1<br />

End<br />

Nail<br />

<strong>USP</strong><br />

Steel Coil<br />

Length<br />

Spacing DF-L (Lbs) DF-L (kN) SPF (Lbs) SPF (kN)<br />

Stock No. Ref. No. Gauge Length Cut Length (in) Qty Type O.C. 100% 115% 100% 115% 100% 115% 100% 115%<br />

CMSTC16 CMSTC16 16 54'<br />

21" <br />

56 10d<br />

42" <br />

7070 7070 31.45 31.45 6655 7070 29.60 31.45<br />

28" 64 16d 9945 9945 44.24 44.24 8960 9945 39.86 44.24<br />

CMST14 CMST14 14 52-1/2' 68" <br />

76 10d<br />

134" <br />

9945 9945 44.24 44.24 9030 9945 40.17 44.24<br />

40" 88 16d 13975 13975 62.17 62.17 12320 13975 54.80 62.17<br />

CMST12 CMST12 12 40' 92" <br />

104 10d<br />

184" <br />

13975 13975 62.17 62.17 12355 13975 54.96 62.17<br />

RS300<br />

RS250<br />

RS200<br />

RS100<br />

RS150<br />

RS14-100<br />

RS22-R<br />

RS20-R<br />

RS18-R<br />

RS16-R<br />

RS14-R<br />

CS22<br />

CS20<br />

CS18<br />

CS18S<br />

CS16<br />

CS14<br />

CS22-R<br />

CS20-R<br />

CS18-R<br />

CS16-R<br />

CS14-R<br />

22<br />

20<br />

18<br />

18<br />

16<br />

14<br />

22<br />

20<br />

18<br />

16<br />

14<br />

300'<br />

250'<br />

200'<br />

100'<br />

150'<br />

100'<br />

25'<br />

25'<br />

25'<br />

25'<br />

25'<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

6"<br />

7"<br />

8"<br />

8"<br />

9"<br />

12"<br />

6"<br />

7"<br />

8"<br />

9"<br />

12"<br />

16<br />

18<br />

20<br />

20<br />

24<br />

30<br />

16<br />

18<br />

20<br />

24<br />

30<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1415<br />

1595<br />

2100<br />

2100<br />

2645<br />

3920<br />

1415<br />

1595<br />

2100<br />

2645<br />

3920<br />

1415<br />

1595<br />

2100<br />

2100<br />

2645<br />

3920<br />

1415<br />

1595<br />

2100<br />

2645<br />

3920<br />

6.29<br />

7.10<br />

9.34<br />

9.34<br />

11.77<br />

17.44<br />

6.29<br />

7.10<br />

9.34<br />

11.77<br />

17.44<br />

6.29<br />

7.10<br />

9.34<br />

9.34<br />

11.77<br />

17.44<br />

6.29<br />

7.10<br />

9.34<br />

11.77<br />

17.44<br />

1390<br />

1595<br />

2010<br />

2010<br />

2645<br />

3565<br />

1390<br />

1595<br />

2010<br />

2645<br />

3565<br />

1415<br />

1595<br />

2100<br />

2100<br />

2645<br />

3920<br />

1415<br />

1595<br />

2100<br />

2645<br />

3920<br />

6.18<br />

7.10<br />

8.94<br />

8.94<br />

11.77<br />

15.86<br />

6.18<br />

7.10<br />

8.94<br />

11.77<br />

15.86<br />

6.29<br />

7.10<br />

9.34<br />

9.34<br />

11.77<br />

17.44<br />

6.29<br />

7.10<br />

9.34<br />

11.77<br />

17.44<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

7"<br />

8"<br />

9"<br />

9"<br />

11"<br />

15"<br />

7"<br />

8"<br />

9"<br />

11"<br />

15"<br />

18<br />

20<br />

24<br />

24<br />

28<br />

38<br />

18<br />

20<br />

24<br />

28<br />

38<br />

8d<br />

8d<br />

8d<br />

8d<br />

8d<br />

8d<br />

8d<br />

8d<br />

8d<br />

8d<br />

8d<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

1415<br />

1595<br />

2100<br />

2100<br />

2645<br />

3920<br />

1415<br />

1595<br />

2100<br />

2645<br />

3920<br />

1415<br />

1595<br />

2100<br />

2100<br />

2645<br />

3920<br />

1415<br />

1595<br />

2100<br />

2645<br />

3920<br />

6.29<br />

7.10<br />

9.34<br />

9.34<br />

11.77<br />

17.44<br />

6.29<br />

7.10<br />

9.34<br />

11.77<br />

17.44<br />

6.29<br />

7.10<br />

9.34<br />

9.34<br />

11.77<br />

17.44<br />

6.29<br />

7.10<br />

9.34<br />

11.77<br />

17.44<br />

1295<br />

1500<br />

2010<br />

2010<br />

2610<br />

3605<br />

1295<br />

1500<br />

2010<br />

2610<br />

3605<br />

1415<br />

1595<br />

2100<br />

2100<br />

2645<br />

3920<br />

1415<br />

1595<br />

2100<br />

2645<br />

3920<br />

5.76<br />

6.67<br />

8.94<br />

8.94<br />

11.61<br />

16.04<br />

5.76<br />

6.67<br />

8.94<br />

11.61<br />

16.04<br />

6.29<br />

7.10<br />

9.34<br />

9.34<br />

11.77<br />

17.44<br />

6.29<br />

7.10<br />

9.34<br />

11.77<br />

17.44<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Fasteners to be installed with equal fasteners at each end of the connection.<br />

3) 16d sinker nails may be substituted for 10d nails with no load reduction.<br />

4) Minimum nail embedment shall be 8 nail diameters (typ).<br />

5) NAILS:<br />

red font.<br />

Typical RS<br />

rim joist installation<br />

CMST similar<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

End<br />

Length<br />

Clear<br />

Span<br />

1˝ Min. End<br />

Length<br />

Cut<br />

Length<br />

1 1 /2˝<br />

3/4˝<br />

1 1 /2˝<br />

3˝ Typ.<br />

1 3 /4˝<br />

3 1 /2˝<br />

1 1 /4˝<br />

1/2˝<br />

RS<br />

3˝<br />

2 1 /4˝<br />

3/4˝<br />

CMSTC16<br />

3˝<br />

1 1 /2˝<br />

1˝<br />

CMST<br />

3/8˝<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®


Strap Ties – HRS, HTP, KST, KSTI, LSTA, LSTI, MSTA, MSTC & ST series<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

HRS – 12 gauge, 13/8˝ or 31/4˝ wide strapping.<br />

LSTA – 20 or 18 gauge, light-capacity 11/4˝ wide strapping.<br />

LSTI – 3 3/4˝ wide strap ties provide tension load path for truss top chords. The nail<br />

pattern accommodates open web trusses with double top chord.<br />

MSTA – 18 or 16 gauge, medium-capacity 11/4˝ wide strapping.<br />

HTP – 16 gauge, medium-capacity 3˝ wide strapping.<br />

ST – 16 gauge, medium-capacity 11/4˝ wide strapping.<br />

MSTC – 3˝ wide strapping. Slotted hole design allows for higher load capacities and<br />

reduce splitting of lumber when attached to multiple 2x members.<br />

KST – 2 1/16˝ wide strapping. Straps can be fastened using either nails or bolts. Some<br />

KST straps install only with nails.<br />

KSTI – 21/16˝ wide strapping. Straps are designed for installation to wood I-Joist flanges.<br />

3˝<br />

L<br />

New<br />

Some model designs may<br />

vary from illustration shown<br />

2 1 /16˝<br />

KST29 9 7 /16˝<br />

KST213 12 11 /16˝<br />

KST216 15 15 /16˝<br />

KST218 19 3 /16˝<br />

KST224 22 7 /16˝<br />

KST234 32 3 /16˝<br />

1 1 /2˝<br />

4 1 /2˝<br />

2 1 /16˝<br />

1 1 /2˝<br />

KST227 27˝<br />

KST237 37 1 /2˝<br />

KST248 48˝<br />

KST260 60˝<br />

KST272 72˝<br />

HTP37-TZ<br />

1 1/4˝<br />

2 1/16˝<br />

3˝<br />

1 1/2˝<br />

3 3/4˝<br />

3 1 ⁄4˝<br />

New<br />

KSTI226 26˝<br />

KSTI236 36˝<br />

KSTI248 48˝<br />

KSTI260 60˝<br />

KSTI272 72˝<br />

1 1/2˝ 3/8˝<br />

typ.<br />

KST scalloped<br />

design<br />

KST<br />

straight edge<br />

design<br />

1 1/4˝<br />

L<br />

3˝<br />

3/4˝<br />

3˝<br />

HRS416-TZ<br />

1 3/8˝<br />

New<br />

LSTA/MSTA 9˝<br />

LSTA/MSTA 12˝<br />

LSTA/MSTA 15˝<br />

LSTA/MSTA 18˝<br />

LSTA/MSTA 21˝<br />

LSTA/MSTA 24˝<br />

LSTA/MSTA 30˝<br />

LSTA/MSTA 36˝<br />

MSTA 48˝<br />

MSTC28 28 1/4˝<br />

MSTC40 40 1/4˝<br />

MSTC52 52 1/4˝<br />

MSTC66 65 3/4˝<br />

MSTC78 77 3/4˝<br />

LSTI49 49˝<br />

LSTI73 73˝<br />

1 1 /2˝<br />

16 5 /16˝<br />

ST9 9 ˝<br />

ST12 11 5/8˝<br />

ST18 17 3/4˝<br />

ST22 21 5/8˝<br />

Angles & Straps<br />

L<br />

HRS12<br />

HRS8<br />

HRS6<br />

HRS<br />

LSTA/MSTA<br />

KSTI MSTC LSTI<br />

KST116 ST<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 77<br />

<strong>USP</strong>2240-131


Strap Ties – HRS, HTP, KST, KSTI, LSTA, LSTI, MSTA, MSTC & ST series cont.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Options: MSTA9, MSTA12, MSTA15, MSTA18, MSTA21, MSTA24, MSTA30,<br />

& MSTA36 are available in Triple Zinc. To order, add TZ to stock<br />

number, as in MSTA9-TZ.<br />

LSTA36, MSTA12, MSTA18, MSTA24, & MSTA36 are available in<br />

Stainless Steel. To order, add SS to stock number, as in MSTA24-SS.<br />

KST227, KST237, KST248, and KST260 are available in Hot-dip<br />

galvanized. To order, add HDG to stock number, as in<br />

KST227-HDG.<br />

Codes: Load values are derived from data submitted to various North<br />

American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Designer may specify alternate nailing schedules. Refer to Nail Specification table on<br />

page 14 for nail shear values. Load values shall not exceed published factored<br />

resistance. The quantity of nails installed shall be equally distributed to both ends of<br />

the strap.<br />

• The quantity of nails installed shall be equally distributed to both ends of the strap.<br />

LTW Twist strap<br />

pages 81-82<br />

Typical LSTA/MSTA I-Joist<br />

on Ridge Beam installation<br />

Typical LSTI open web<br />

truss installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Dimensions (in) Fastener Schedule 2,6 Factored Resistance 1,5<br />

Uplift 115%<br />

Angles & Straps<br />

<strong>USP</strong><br />

Steel<br />

Total Min<br />

Stock No. Ref. No. Gauge W L Qty 3 Qty 4 Type DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

KST116 ST2115 20 3/4 16-5/16 10 8 16d 995 4.43 940 4.18<br />

LSTA9 LSTA9 20 1-1/4 9 8 8 10d 1085 4.83 775 3.45<br />

LSTA12 LSTA12 20 1-1/4 12 10 10 10d 1355 6.03 970 4.31<br />

LSTA15 LSTA15 20 1-1/4 15 12 12 10d 1630 7.25 1165 5.18<br />

LSTA18 LSTA18 20 1-1/4 18 14 14 10d 1855 8.25 1360 6.05<br />

LSTA21 LSTA21 20 1-1/4 21 16 16 10d 1855 8.25 1555 6.92<br />

LSTA24 LSTA24 20 1-1/4 24 18 16 10d 1855 8.25 1555 6.92<br />

KST29 ST292 20 1-3/4 9-7/16 14 14 16d 1320 5.87 940 4.18<br />

KST213 ST2122 20 1-3/4 12-11/16 18 18 16d 2680 11.92 2110 9.39<br />

KST216 ST2215 20 1-3/4 15-15/16 22 18 16d 2680 11.92 2110 9.39<br />

LSTA30 LSTA30 18 1-1/4 30 22 22 10d 2460 10.94 2140 9.52<br />

LSTA36 LSTA36 18 1-1/4 36 26 22 10d 2460 10.94 1945 8.65<br />

MSTA9 MSTA9 18 1-1/4 9 8 8 10d 1085 4.83 775 3.45<br />

MSTA12 MSTA12 18 1-1/4 12 10 10 10d 1355 6.03 970 4.31<br />

MSTA15 MSTA15 18 1-1/4 15 12 12 10d 1630 7.25 1165 5.18<br />

MSTA18 MSTA18 18 1-1/4 18 14 14 10d 1900 8.45 1360 6.05<br />

MSTA21 MSTA21 18 1-1/4 21 16 16 10d 2170 9.65 1555 6.92<br />

MSTA24 MSTA24 18 1-1/4 24 18 18 10d 2445 10.88 1750 7.78<br />

LSTI49 LSTI49 18 3-3/4 49 32 32 10d x 1-1/2 4340 19.31 3090 13.75<br />

LSTI73 LSTI73 18 3-3/4 73 48 48 10d x 1-1/2 6515 28.98 4635 20.62<br />

ST9 ST9 16 1-1/4 9 8 8 16d 1325 5.89 1100 4.89<br />

ST12 ST12 16 1-1/4 11-5/8 10 10 16d 1655 7.36 1375 6.12<br />

ST18 ST18 16 1-1/4 17-3/4 14 14 16d 2095 9.32 1925 8.56<br />

ST22 ST22 16 1-1/4 21-5/8 18 18 16d 2095 9.32 2095 9.32<br />

MSTA30 MSTA30 16 1-1/4 30 22 22 10d 2985 13.28 2140 9.52<br />

MSTA36 MSTA36 16 1-1/4 36 26 26 10d 3100 13.79 2525 11.23<br />

MSTA48 MSTA49 16 1-1/4 48 32 26 10d 3070 13.66 2525 11.23<br />

KST218 ST6215 16 1-3/4 19-3/16 26 26 16d 2640 11.74 1875 8.34<br />

KST224 ST6224 16 1-3/4 22-7/16 30 30 16d 4440 19.75 3520 15.66<br />

HTP37-TZ HTP37Z 16 3 7 20 20 10d x 1-1/2 2330 10.36 2110 9.39<br />

MSTC28<br />

MSTC40<br />

MSTC52<br />

MSTC28<br />

MSTC40<br />

MSTC52<br />

16<br />

16<br />

16<br />

3<br />

3<br />

3<br />

28-1/4<br />

40-1/4<br />

52-1/4<br />

36<br />

52<br />

70<br />

36<br />

52<br />

60<br />

10d<br />

10d<br />

10d<br />

4380<br />

6570<br />

7795<br />

19.48<br />

29.23<br />

34.68<br />

3110<br />

4665<br />

6220<br />

13.83<br />

20.75<br />

27.67<br />

36<br />

52<br />

70<br />

34<br />

46<br />

52<br />

16d<br />

16d<br />

16d<br />

6295<br />

7795<br />

7795<br />

28.00<br />

34.68<br />

34.68<br />

4435<br />

6305<br />

7795<br />

19.73<br />

28.05<br />

34.68<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) Total number of nail and/or bolt holes provided in the strap.<br />

4) Minimum quantity of fasteners to be installed with equal fasteners at each end of the connection. Product<br />

may have additional nail holes not needed to meet published allowable load of product.<br />

<br />

6) NAILS:<br />

New products or updated product information are designated in red font.<br />

continued on next page<br />

78<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

<strong>USP</strong> Steel Total Min<br />

3<br />

4<br />

KST234 ST6236 14 1-3/4 32-3/16 42 36 16d 5665 25.20 4225 18.79<br />

MSTC66 14 3 65-3/4<br />

88 72 10d 9945 44.24 8165 36.32


Strap Ties – HRS, HTP, KST, KSTI, LSTA, LSTI, MSTA, MSTC & ST series cont.<br />

Dimensions (in) Fastener Schedule 2,6<br />

Factored Resistance 1,5<br />

Steel<br />

Uplift 115%<br />

<strong>USP</strong><br />

Gaug<br />

Total Min<br />

Stock No. Ref. No. e W L Qty 3 Qty 4 Type DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

KST234 ST6236 14 1-3/4 32-3/16 42 36 16d 5665 25.20 4225 18.79<br />

MSTC66 MSTC66 14 3 65-3/4<br />

88 72 10d 9945 44.24 8165 36.32<br />

88 62 16d 9945 44.24 9945 44.24<br />

MSTC78 MSTC78 14 3 77-3/4<br />

104 76 10d 9945 44.24 8550 38.03<br />

104 66 16d 9945 44.24 9945 44.24<br />

HRS6 HRS6 12 1-3/8 6 6 6 10d 815 3.63 580 2.58<br />

HRS8 HRS8 12 1-3/8 8 10 10 10d 1355 6.03 970 4.31<br />

HRS12 HRS12 12 1-3/8 12 14 14 10d 1900 8.45 1355 6.03<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

KST227<br />

KST237<br />

MST27,<br />

S/MST27<br />

MST37,<br />

S/MST37<br />

12 2-1/16 27 34 26 16d 4290 19.08 3050 13.57<br />

12 2-1/16 37-1/2 48 38 16d 6270 27.89 4455 19.82<br />

KST248<br />

MST48,<br />

S/MST48<br />

12 2-1/16 48 62 50 16d 8110 36.08 5865 26.09<br />

KSTI226 MSTI26 12 2-1/16 26 26 26 10d x 1-1/2 2985 13.28 2125 9.45<br />

KSTI236 MSTI36 12 2-1/16 36 36 36 10d x 1-1/2 4340 19.31 3090 13.75<br />

KSTI248 MSTI48 12 2-1/16 48 48 48 10d x 1-1/2 5970 26.56 4250 18.91<br />

KSTI260 MSTI60 12 2-1/16 60 60 60 10d x 1-1/2 7600 33.81 5410 24.07<br />

KSTI272 MSTI72 12 2-1/16 72 72 60 10d x 1-1/2 8110 36.08 6570 29.23<br />

HRS416-TZ HRS416Z 12 3-1/4 16 16 16 WS15-GC 4057 18.05 3329 14.81<br />

KST260<br />

MST60,<br />

S/MST60<br />

10 2-1/16 60 72 64 16d 10560 46.98 7505 33.39<br />

KST272<br />

MST72,<br />

S/MST72<br />

10 2-1/16 72 72 64 16d 10605 47.18 8445 37.57<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) Total number of nail and/or bolt holes provided in the strap.<br />

4) Minimum quantity of fasteners to be installed with equal fasteners at each end of the connection. Product may have<br />

additional nail holes not needed to meet published allowable load of product.<br />

<br />

6) NAILS:<br />

New products or updated product information are designated in red font.<br />

Clear Span Chart<br />

<strong>USP</strong><br />

Stock No.<br />

MSTC28 MSTC28<br />

MSTC40<br />

MSTC52<br />

MSTC66 MSTC66<br />

MSTC78 MSTC78<br />

KST237<br />

KST248<br />

KST260<br />

KST272<br />

Factored Resistance 1<br />

Clear<br />

Uplift (115%)<br />

Ref. No. Span Qty Type DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

MSTC40<br />

MSTC52<br />

<br />

S/MST37<br />

<br />

S/MST48<br />

<br />

S/MST60<br />

<br />

S/MST72<br />

KSTI236 MSTI36<br />

KSTI248 MSTI48<br />

KSTI260 MSTI60<br />

KSTI272 MSTI72<br />

Fasteners Total 2,3<br />

18 12 10d 1630 7.30 1155 5.10<br />

16 16 10d 2170 9.70 1540 6.90<br />

18 28 10d 3800 16.90 2700 12.00<br />

16 32 10d 4345 19.30 3085 13.70<br />

18 44 10d 5970 26.60 4240 18.90<br />

16 48 10d 6515 29.00 4625 20.60<br />

18 62 10d 8415 37.40 5975 26.60<br />

16 64 10d 8685 38.60 6165 27.40<br />

18 64 10d 8685 38.60 6165 27.40<br />

16 66 10d 8960 39.90 6360 28.30<br />

18 20 16d 3295 14.70 2340 10.40<br />

16 22 16d 3625 16.10 2575 11.50<br />

18 32 16d 5275 23.50 3745 16.70<br />

16 34 16d 5605 24.90 3980 17.70<br />

18 46 16d 7580 33.70 5380 23.90<br />

16 48 16d 7910 35.20 5615 25.00<br />

18 46 16d 7580 33.70 5380 23.90<br />

16 48 16d 7910 35.20 5615 25.00<br />

18 14 10d x 1-1/2 1900 8.50 1355 6.00<br />

16 16 10d x 1-1/2 2170 9.70 1550 6.90<br />

18 26 10d x 1-1/2 3530 15.70 2520 11.20<br />

16 28 10d x 1-1/2 3800 16.90 2715 12.10<br />

18 38 10d x 1-1/2 5155 22.90 3685 16.40<br />

16 40 10d x 1-1/2 3585 15.90 3585 15.90<br />

18 50 10d x 1-1/2 6520 29.00 4845 21.60<br />

16 52 10d x 1-1/2 6520 29.00 5040 22.40<br />

1) Factored resistances have been increased 15% for short-term<br />

loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

<br />

Optional nails<br />

(wood shrinkage may<br />

occur and cause strap<br />

to buckle outward)<br />

1˝ Min.<br />

End length<br />

Clear<br />

span<br />

End length<br />

Typical KST237<br />

floor-to-floor installation<br />

Angles & Straps<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 79<br />

<strong>USP</strong>2240-131


Strap Ties – KRPS series<br />

Designed for notched plates where plumbing, heating, or<br />

other pipes are placed in partitions.<br />

.<br />

Materials: 16 gauge<br />

Finish: G90 galvanizing<br />

Options: KRPS22 and KRPS28 are is available in<br />

Triple Zinc. To order, add TZ to stock<br />

number, as in KRPS22-TZ.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

<strong>USP</strong><br />

Stock No.<br />

Dimensions (in) Fastener Schedule 2,4 Factored Resistance (115%) 1,3<br />

Steel<br />

Notch<br />

DF-L<br />

S-P-F<br />

Ref. No. Gauge W L Width Qty Type Lbs kN Lbs kN<br />

KRPS18 RPS18 16 1-1/2 18-5/16 12 16d 1375 6.12 1185 5.27<br />

KRPS22 RPS22 16 1-1/2 22-5/16 < 16 16d 1785 7.94 1535 6.83<br />

KRPS28 RPS28 16 1-1/2 28-5/16 < 16 16d 1785 7.94 1535 6.83<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

<br />

4) NAILS:<br />

New products or updated product information are designated in red font.<br />

Typical KRPS installation<br />

KRPS18 & KRPS22 5 1 /2˝<br />

KRPS28 12˝<br />

end of notch distance<br />

L<br />

1 1 /2˝<br />

KRPS<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Pre-Bent Strap – MSTCB series<br />

The MSTCB Pre-Bent Strap is designed to<br />

fasten vertical studs to a beam or ridge beam<br />

member below where the beam depth will not<br />

allow complete fastener attachments with a<br />

standard product.<br />

Materials: 14 gauge<br />

Finish: G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product<br />

Notes, page 10.<br />

NEW<br />

SIZE<br />

Stud<br />

Fastening<br />

Minimum<br />

(2) 2x or 4x<br />

Minimum<br />

Length 22˝<br />

W<br />

L<br />

Angles & Straps<br />

3˝ Minimum<br />

Bearing Area<br />

Sideview<br />

Typical MSTC66B3<br />

installation<br />

No Nails<br />

Required<br />

Face Nailing<br />

Dimensions (in) Minimum<br />

Fastener Schedule 2,7<br />

Factored Resistance<br />

Beam<br />

Beam<br />

Stud/Post 3,5,6<br />

Tension<br />

Dimensions<br />

(in) Face Bottom<br />

DF-L S-P-F<br />

<strong>USP</strong><br />

Steel<br />

Lbs. kN Lbs. kN<br />

Stock No. Ref. No. Gauge W L B W D Qty Type Qty Type Qty Type 115% 115% 115% 115%<br />

MSTC48B3 MSTC48B3 14 3 44-7/8 2-7/8 3 9-1/4 12 10d 4 10d 24 10d 7185 32.0 5100 22.69<br />

MSTC66B3 MSTC66B3 14 3 62-7/8 2-7/8 3 11-1/4 14 10d 4 10d 24 10d 7185 32.0 5100 22.69<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) Minimum strap length on stud/post for quantity of nails is 19" for MSTC48B3 and 22" for MSTC66B3.<br />

4) The 3" wide beam may be double for 2x members.<br />

5) Fewer fasteners in the stud/post than listed will reduce the capacity of the connection.<br />

6) Nails in the stud/post to be installed symmetrically in pairs starting a minimum of 1-1/2" from the end.<br />

7) NAILS:<br />

New products or updated product information are designated in red font.<br />

B<br />

MSTC66B3<br />

80<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Twist Straps – HTW, KTS, LFTA6, LTW, & MTW series<br />

Twist straps tie framing members to resist tension forces.<br />

LFTA6 – 16 gauge.<br />

LTW – 18 gauge, light-capacity.<br />

MTW – 16 gauge, medium-capacity.<br />

KTS – 16 gauge, medium-capacity with angled twist.<br />

HTW – 14 gauge, heavy-capacity.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Options: LFTA6, HTW20, MTW12, MTW16, MTW20,<br />

and MTW30 are available in Triple Zinc.<br />

To order, add TZ to stock number, as in<br />

MTW12-TZ.<br />

LTW12, LTW18, & MTW20 are available in<br />

Stainless Steel. To order, add SS to stock<br />

number, as in LTW18-SS.<br />

Codes: Load values are derived from data submitted<br />

to various North American building code<br />

evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Consult I-Joist manufacturer for web stiffener<br />

requirements, and uplift limitations on joist and application.<br />

Typical LFTA6 stud-to-top<br />

plate installation<br />

6 1 /2˝<br />

8 3 /8˝<br />

19 1 /8˝<br />

LFTA6<br />

2 1 /4˝<br />

Typical LFTA6 truss-to-top<br />

plate installation<br />

Uplift<br />

F 1<br />

Place strap so all<br />

nail holes align<br />

with rim joist<br />

Typical LFTA6 stud-to-rim<br />

joist installation<br />

Typical LTW12 / MTW12<br />

Truss-to-top plate<br />

installation<br />

Uplift<br />

Equal number of specified<br />

fasteners at each end<br />

Typical LTW12 / MTW12<br />

Stud-to-rim joist<br />

installation<br />

L 1<br />

1˝ Typ.<br />

L 2<br />

1 1 /4˝<br />

LTW12/MTW12<br />

L<br />

1 1 /4˝<br />

1˝<br />

Typ.<br />

LTW18/MTW18<br />

other models similar<br />

Angles & Straps<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 81<br />

<strong>USP</strong>2240-131


Twist Straps – HTW, KTS, LFTA6, LTW, & MTW series cont.<br />

Angles & Straps<br />

Dimensions (in)<br />

Fastener Schedule 2,3,4,5,8<br />

Factored Uplift Resistance (115%) 1<br />

<strong>USP</strong><br />

Steel<br />

DF-L<br />

S-P-F<br />

Stock No. 6 Ref. No. Gauge W L L1 L2 Qty Type Lbs kN Lbs kN<br />

LTW12<br />

LTW16<br />

LTW18<br />

LTW20<br />

LTS12<br />

LTS16<br />

LTS18<br />

LTS20<br />

18<br />

18<br />

18<br />

18<br />

1-1/4<br />

1-1/4<br />

1-1/4<br />

1-1/4<br />

12<br />

16<br />

18<br />

20<br />

4-1/2<br />

6-1/2<br />

7-1/2<br />

8-1/2<br />

4-1/2<br />

6-1/2<br />

7-1/2<br />

8-1/2<br />

12<br />

12<br />

12<br />

12<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

1465<br />

1465<br />

1465<br />

1465<br />

6.52<br />

6.52<br />

6.52<br />

6.52<br />

1040<br />

1040<br />

1040<br />

1040<br />

4.63<br />

4.63<br />

4.63<br />

4.63<br />

12<br />

12<br />

12<br />

12<br />

10d<br />

10d<br />

10d<br />

10d<br />

1465<br />

1465<br />

1465<br />

1465<br />

6.52<br />

6.52<br />

6.52<br />

6.52<br />

1040<br />

1040<br />

1040<br />

1040<br />

4.63<br />

4.63<br />

4.63<br />

4.63<br />

KTS9 TS9 16 1-1/4 9 -- -- -- -- 8 16d 915 4.07 785 3.49<br />

KTS12 TS12 16 1-1/4 11-1/2 -- -- -- -- 10 16d 1145 5.09 985 4.38<br />

MTW12<br />

MTW16<br />

MTS12<br />

MTS16<br />

16<br />

16<br />

1-1/4<br />

1-1/4<br />

12<br />

16<br />

4-1/2<br />

6-1/2<br />

4-1/2<br />

6-1/2<br />

14<br />

14<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

2250<br />

2250<br />

10.01<br />

10.01<br />

1595<br />

1595<br />

7.10<br />

7.10<br />

14<br />

14<br />

10d<br />

10d<br />

2250<br />

2250<br />

10.01<br />

10.01<br />

1595<br />

1595<br />

7.10<br />

7.10<br />

KTS17 TS18 16 1-1/4 17-1/2 -- -- -- -- 14 16d 1370 6.09 1175 5.23<br />

MTW18<br />

LFTA6 7<br />

MTW20<br />

MTS18<br />

<br />

MTS20<br />

16<br />

16<br />

16<br />

1-1/4<br />

2-1/4<br />

1-1/4<br />

18<br />

19-1/8<br />

20<br />

7-1/2<br />

8-3/8<br />

8-1/2<br />

7-1/2<br />

6-1/2<br />

8-1/2<br />

14<br />

16<br />

14<br />

10d x 1-1/2<br />

8d<br />

10d x 1-1/2<br />

2250<br />

1265<br />

2250<br />

10.01<br />

5.63<br />

10.01<br />

1595<br />

1075<br />

1595<br />

7.10<br />

4.78<br />

7.10<br />

14<br />

16<br />

14<br />

10d<br />

8d x1-1/2<br />

10d<br />

2250<br />

1265<br />

2250<br />

10.01<br />

5.63<br />

10.01<br />

1595<br />

1075<br />

1595<br />

7.10<br />

4.78<br />

7.10<br />

KTS24 TS22 16 1-1/4 21-3/4 -- -- -- -- 18 16d 1580 7.03 1580 7.03<br />

MTW24C<br />

MTW28C<br />

MTW30<br />

MTW30C<br />

HTW16<br />

HTW20<br />

HTW24<br />

HTW28<br />

HTW30<br />

HTW30C<br />

MTS24C<br />

-- --<br />

MTS30<br />

MTS30C<br />

HTS16<br />

HTS20<br />

HTS24<br />

HTS28<br />

HTS30<br />

HTS30C<br />

16<br />

16<br />

16<br />

16<br />

14<br />

14<br />

14<br />

14<br />

14<br />

14<br />

1-1/4<br />

1-1/4<br />

1-1/4<br />

1-1/4<br />

1-1/4<br />

1-1/4<br />

1-1/4<br />

1-1/4<br />

1-1/4<br />

1-1/4<br />

24<br />

28<br />

30<br />

30<br />

16<br />

20<br />

24<br />

28<br />

30<br />

30<br />

10-7/16<br />

12-7/16<br />

8-5/16<br />

13-7/16<br />

5-1/8<br />

7-1/8<br />

9-1/8<br />

11-1/8<br />

7<br />

12-1/8<br />

10-7/16<br />

12-7/16<br />

18-9/16<br />

13-7/16<br />

5-1/8<br />

7-1/8<br />

9-1/8<br />

11-1/8<br />

17-1/4<br />

12-1/8<br />

14<br />

14<br />

14<br />

14<br />

16<br />

24<br />

24<br />

24<br />

24<br />

24<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

2250<br />

2250<br />

2250<br />

2250<br />

2340<br />

2880<br />

2880<br />

2880<br />

2880<br />

2880<br />

10.01<br />

10.01<br />

10.01<br />

10.01<br />

10.41<br />

12.81<br />

12.81<br />

12.81<br />

12.81<br />

12.81<br />

1595<br />

1595<br />

1595<br />

1595<br />

1660<br />

2045<br />

2045<br />

2045<br />

2045<br />

2045<br />

7.10<br />

7.10<br />

7.10<br />

7.10<br />

7.38<br />

9.10<br />

9.10<br />

9.10<br />

9.10<br />

9.10<br />

14<br />

14<br />

14<br />

14<br />

16<br />

20<br />

20<br />

20<br />

20<br />

20<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

2250<br />

2250<br />

2250<br />

2250<br />

2340<br />

2880<br />

2880<br />

2880<br />

2880<br />

2880<br />

10.01<br />

10.01<br />

10.01<br />

10.01<br />

10.41<br />

12.81<br />

12.81<br />

12.81<br />

12.81<br />

12.81<br />

1595<br />

1595<br />

1595<br />

1595<br />

1660<br />

2045<br />

2045<br />

2045<br />

2045<br />

2045<br />

7.10<br />

7.10<br />

7.10<br />

7.10<br />

7.38<br />

9.10<br />

9.10<br />

9.10<br />

9.10<br />

9.10<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) 16d sinker nails may be substituted for 10d common nails with no reduction in load.<br />

<br />

5) Fasteners shall be distributed equally on each end of the connection.<br />

6) C after the model number designates center twist as in MTW30C.<br />

<br />

closest to the bend line. Lateral F1 and F2 load directions do not apply to roof truss-to-top plate installations.<br />

8) NAILS:<br />

<br />

New products or updated product information are designated in red font.<br />

L 1<br />

Typical MTW20<br />

I-Joist Rafter<br />

installation<br />

Typical MTW30<br />

installation<br />

L 1<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

L<br />

L 2<br />

L 2<br />

1 1 /4˝<br />

1 1 /4˝<br />

KTS<br />

MTW30C<br />

MTW30/<br />

HTW30<br />

82<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Permanent Wood Foundation Strap – PWFS24<br />

Connects permanent wood foundation studs to rim joist to resist lateral<br />

loads produced from ground pressure. The high load values and positive<br />

placement nail gun installation make the PWFS24 practical for<br />

manufactured homes as well as site built homes.<br />

Materials: 20 gauge<br />

Finish: G90 galvanizing<br />

Load direction<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Centre strap on top plate over the stud.<br />

• Attach centre nail and bend inside end of strap downward.<br />

• Install nails on inside of wall.<br />

• Install floor system or place manufactured home on foundation.<br />

Typical PWFS24<br />

• Form outside end of strap up the outside of rim and install nails.<br />

installation<br />

Dimensions (in) Fastener Schedule 1,3<br />

<strong>USP</strong><br />

Steel<br />

DF-L<br />

S-P-F<br />

Stock No. Ref. No. Gauge W L Qty Type Lbs kN Lbs kN<br />

PWFS24 PWF24 20 1-1/2 24 9 8d 1115 4.96 930 4.14<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2 For installations where the strap does not fall behind joist, the designer shall be responsible to<br />

determine suitability of rim to resist the load.<br />

3) NAILS:<br />

Factored Resistance (100%) 2<br />

1 1 /2˝<br />

24˝<br />

PWFS24<br />

Angles & Straps<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 83<br />

<strong>USP</strong>2240-131


Masonry Strap Ties – MSTAM & MSTCM series<br />

The MSTAM and MSTCM Strap Ties are designed to connect a<br />

wood structure above to a masonry wall below.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Options: MSTAM24 and MSTAM36 are available in Triple<br />

Zinc. To order, add TZ to the stock number, as in<br />

MSTAM36-TZ.<br />

NEW<br />

SIZE<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

12 1/2˝ 12 1/2˝<br />

minimum minimum<br />

3˝ minimum 3˝ minimum<br />

3˝ minimum 3˝ minimum<br />

14˝ 14˝<br />

minimum minimum<br />

1 1/ 2˝<br />

3˝<br />

L<br />

5/8˝<br />

3˝<br />

L<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Typical MSTCM40<br />

installation<br />

Typical MSTAM36<br />

installation<br />

W<br />

MSTCM40<br />

W<br />

MSTAM36<br />

Angles & Straps<br />

Dimensions (in)<br />

Fastener Schedule<br />

Factored Resistance 1<br />

CMU 3 Concrete 3 Nails 2<br />

Uplift (115%)<br />

<strong>USP</strong><br />

Steel<br />

DF-L<br />

S-P-F<br />

Stock No. Ref. No. Gauge W L Qty Type Qty Type Qty Type Lbs kN Lbs kN<br />

MSTAM24 MSTAM24 18 1-1/4 24 5 5 9 10d 2315 10.30 2315 10.30<br />

MSTAM36 MSTAM36 16 1-1/4 36 8 8 10 10d 2920 12.99 2820 12.54<br />

16 3 40-1/4 14 14 <br />

24 10d<br />

22 16d<br />

6905 30.72 4905 21.82<br />

MSTCM60 16 3 60 14 14 <br />

24 10d<br />

22 16d<br />

6905 30.72 4905 21.82<br />

<br />

<br />

<br />

red font.<br />

Clear Span Chart<br />

<strong>USP</strong><br />

Stock No.<br />

<br />

<br />

MSTCM60<br />

Fastener Schedule Factored Resistance 3<br />

CMU 1 Concrete 1 Nails 2 Uplift (115%)<br />

Clear<br />

DF-L S-P-F<br />

Span Qty Type Qty Type Qty Type Lbs kN Lbs kN<br />

16 5 5 8 10d 1825 8.12 1445 6.43<br />

18 5 5 7 10d 1825 8.12 1445 6.43<br />

16 14 14 14 16d 4700 20.91 4380 19.48<br />

18 14 14 14 16d 4700 20.91 4380 19.48<br />

16 14 14 22 16d 6905 30.72 4905 21.82<br />

18 14 14 22 16d 6905 30.72 4905 21.82<br />

<br />

<br />

<br />

<br />

red font.<br />

84<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Masonry Twist Straps – HTWM series<br />

The HTWM Twist Straps are designed for truss to concrete or<br />

masonry connections. Offer uplift resistance with variable heel<br />

height and positioning applications.<br />

Materials: 14 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted<br />

to various North American building code<br />

evaluators.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Installation Instructions:<br />

• Use all specified fasteners. See Product Notes pages 10.<br />

• Strap may be attached to either side of grouted masonry or<br />

concrete wall with a minimum of (1) #5 horizontal rebar.<br />

• Drill hole in concrete or masonry with manufacturers<br />

prescribed 3/16˝ masonry drill. Install fasteners into concrete or<br />

masonry per manufacturer’s specification.<br />

• Grout or concrete compressive strength shall be 2,000 psi at<br />

28 days.<br />

• Twist straps do not have to be wrapped over the truss to<br />

achieve the factored resistance.<br />

• Moisture barrier may be required.<br />

Typical HTWM<br />

installation<br />

W<br />

L 1<br />

L<br />

L 1<br />

W<br />

HTWM<br />

CMU 2 Concrete 2<br />

Dimensions (in)<br />

Fastener Schedule<br />

Factored Resistance 1<br />

Truss/Rafter 2,3<br />

Uplift (115%)<br />

<strong>USP</strong><br />

Steel<br />

Nail<br />

DF-L<br />

S-P-F<br />

Stock No. Ref. No. Gauge W L L1 Qty Wedge Bolts Qty Wedge Bolts Qty Type Lbs kN Lbs kN<br />

HTWM16 HTSM16, MTSM16 14 1-1/4 16 5-3/4 4 4 8 6.76 1335 5.94<br />

14 1-1/4 7-3/4 4 4 8 6.76 1335 5.94<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

<br />

3) NAILS:<br />

Angles & Straps<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 85<br />

<strong>USP</strong>2240-131


<strong>Hangers</strong><br />

Hanger Selector Guide . . . . . . . . . . Page 87<br />

Face Mount Joist <strong>Hangers</strong> . . Pages 88-96<br />

• ST Series<br />

Light-capacity 22 gauge joist hanger.<br />

• DT Series<br />

Light-capacity 22 gauge joist hanger.<br />

• JL Series<br />

Light-capacity 20 gauge joist hanger.<br />

• JLIF Series<br />

Inverted flange 18 gauge joist hanger.<br />

• SUH Series<br />

Medium-capacity 16 gauge joist hanger.<br />

• JUS Series<br />

Medium-capacity 18 gauge joist hanger with slant nailing.<br />

• MUS Series<br />

Medium-capacity 18 gauge joist hanger with slant nailing.<br />

• HUS Series<br />

Heavy-capacity 14 or 16 gauge joist hanger with slant nailing.<br />

• HD Series<br />

Heavy-capacity 14 gauge joist hanger.<br />

• HDQIF Series<br />

Inverted flange 14 gauge joist hanger.<br />

ST<br />

SUH<br />

HD<br />

DT<br />

JUS<br />

HDQIF<br />

JL<br />

MUS<br />

JLIF<br />

HUS<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Top Mount <strong>Hangers</strong> . . . . . . . Pages 97-102<br />

• KLB Series<br />

Light-capacity 14 gauge top mount hanger with uplift capacity.<br />

• KB Series<br />

Medium-capacity 12 gauge top mount hanger with uplift capacity.<br />

• HDO Series<br />

Medium-capacity 12 gauge top mount hanger with uplift capacity.<br />

• SW Series<br />

Light-capacity welded hanger with primer finish.<br />

• SWH Series<br />

Medium-capacity welded hanger with primer finish.<br />

• KHW Series<br />

Heavy-capacity welded hanger with primer finish.<br />

• HL Series<br />

Light-capacity 18 gauge 2x top mount hanger.<br />

• JH Series<br />

Medium-capacity strap style hanger.<br />

KLB<br />

SWH<br />

KB<br />

KHW<br />

HDO<br />

HL<br />

SW<br />

JH<br />

Slope & Skew <strong>Hangers</strong> . . . . Pages 103-105<br />

• LSSH Series<br />

Field adjustable slope and skew hanger.<br />

• SKH Series<br />

Light-capacity 45° skewed hanger.<br />

• SKHH Series<br />

Medium-capacity 45° skewed hanger.<br />

• LS Series<br />

Light-capacity hanger for slopes from 0° up to 30° down.<br />

LSSH<br />

SKH<br />

SKHH<br />

LS<br />

<strong>Hangers</strong><br />

86<br />

Masonry <strong>Hangers</strong> . . . . . . . Pages 106-109<br />

• HWUH Series<br />

Heavy-capacity top flange masonry hanger.<br />

• MPH Series<br />

Top flange masonry hanger.<br />

• UMH Series<br />

Face mount masonry hanger.<br />

HWUH MPH UMH<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


<strong>Hangers</strong><br />

Panel & Purlin <strong>Hangers</strong> . . Pages 110-112<br />

• FHD26<br />

Medium-capacity purlin saddle hanger.<br />

• JPF Series<br />

Medium-capacity purlin hanger with double shear nailing.<br />

• JDS Series<br />

Medium-capacity purlin saddle hanger.<br />

• DTUS & TUS Series<br />

Medium-capacity 16 gauge joist hanger.<br />

FHD26<br />

JPF<br />

JDS<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Hanger Selector Guide<br />

Style<br />

Supported / Joist Member<br />

Supporting / Header Member<br />

DTUS<br />

100% Factored Resistance (Lbs.) Range<br />

Header Material<br />

TUS<br />

Hanger<br />

Type<br />

Face<br />

Mount<br />

Top<br />

Mount<br />

Slope<br />

and<br />

Skew<br />

Panel and<br />

Purlin<br />

Masonry<br />

Face Mount<br />

Top Mount<br />

Sloped / Skewed<br />

Formed<br />

Welded<br />

Dimensional Wood<br />

<strong>USP</strong><br />

Series<br />

Steel<br />

Gauge<br />

ST 22 670 - 1,520 670 - 1,520 -- -- -- --<br />

DT 22 1,380 - 1,640 1,380 - 1,640 -- -- -- --<br />

JL 20 970 - 3,070 689 - 2,180 -- -- -- --<br />

JUS 18 1,580 - 5,170 1,122 - 3,671 -- -- -- --<br />

MUS 18 3,245 - 4,400 2,305 - 3,125 -- -- -- --<br />

JLIF 18 670 - 1,835 475 - 1,305 -- -- -- --<br />

SUH 16 1,390 - 5,730 985 - 4,070 -- -- -- --<br />

HUS<br />

16 5,480 - 9,025 3,891 - 6,408 -- -- -- --<br />

14 2,130 - 6,345 1,512 - 4,505 -- -- -- --<br />

HD 14 1,535 - 7,315 1,090 - 5,194 -- -- -- --<br />

HDQIF 14 5,315 - 8,460 3,775 - 6,005 -- -- -- --<br />

KLB 14 2,235 1,585 -- -- -- --<br />

KB 12 4,165 - 5,075 2,960 - 3,605 -- -- -- --<br />

HDO 12 3,125 - 7,885 2,625 - 6,625 -- -- -- --<br />

SW 12 3,335 - 3,630 2,265 - 2,470 -- -- -- --<br />

SWH<br />

7 - Top Flange<br />

12 - Stirrup<br />

4,760 3,235 -- -- -- --<br />

KHW<br />

3 - Top Flange<br />

10 - Stirrup<br />

7,625 - 7,680 5,185 - 5,225 -- -- -- --<br />

HL 18 1,830 - 2,290 1,245 -1,925 -- -- -- --<br />

JH 18 3,565 - 4,750 2,745 - 3,375 -- -- -- --<br />

LS 18 1,370 - 1,765 1,180 - 1,520 -- -- -- --<br />

LSSH<br />

18 1,340 - 2,775 950 - 1,970 -- -- -- --<br />

16 2,985 - 5,230 2,120 - 3,715 -- -- -- --<br />

SKH<br />

16 825 - 5,065 585 - 3,595 -- -- -- --<br />

14 2,575 - 7,405 1,830 - 5,260 -- -- -- --<br />

SKHH 14 2,175 - 5,240 1,880 - 4,530 -- -- -- --<br />

JDS 18 785 - 2,735 560 - 1,940 -- -- -- --<br />

FHD 18 1,575 1,120 -- -- -- --<br />

JPF 20 1,755 - 1,995 1,245 - 1,420<br />

DTUS 20 980 695 -- -- -- --<br />

TUS 20 980 695 -- -- -- --<br />

HWUH<br />

1/4"- Top Flange,<br />

7 - Stirrup<br />

-- -- -- -- 5,010 - 8,625 3,555 - 6,125<br />

MPH 12 -- -- -- -- 3,745 - 6,165 3,220 - 5,300<br />

UMH 1 1/4" -- -- -- -- 11,875 8,430<br />

1) UMH factored resistance values are based upon 2,500 psi.<br />

<br />

red font.<br />

<strong>EWP</strong><br />

Truss<br />

Glulam<br />

Dimensional Wood<br />

<strong>EWP</strong><br />

Truss<br />

Glulam<br />

Masonry<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 87<br />

<strong>USP</strong>2240-131<br />

DF-L<br />

SPF<br />

DF-L Masonry<br />

SPF Masonry<br />

<strong>Hangers</strong>


Standard Joist <strong>Hangers</strong> – DT, JL, JLIF, ST & SUH series<br />

<strong>USP</strong> offers a wide variety of light-gauge face mount joist hangers to<br />

accommodate application and installation preferences.<br />

ST series – 22 gauge, 2x joist hangers.<br />

DT series – 22 gauge, (2) 2x joist hangers.<br />

JL series – 20 gauge, 2x joist hangers.<br />

JLIF series – 18 gauge, 2x joist hangers.<br />

SUH series – 16 gauge steel construction for more demanding<br />

applications and light truss support.<br />

Materials: See chart<br />

Finish: G90 galvanizing; JLIF – G-185 galvanizing<br />

Options: JL26IF and JL210IF are available in Stainless Steel.<br />

To order, add SS to stock number, as in JL26IF-SS.<br />

See SUH Specialty Options Chart.<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

Typical JL26<br />

installation<br />

JL26<br />

Typical SUH26-2<br />

installation<br />

W<br />

SUH26-2<br />

A<br />

D<br />

H<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

SUH Specialty Options Chart – refer to Specialty<br />

Options pages 210 to 211 for additional details.<br />

Typical ST<br />

installation<br />

Typical DT<br />

installation<br />

A<br />

Option 4 Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3<br />

Range<br />

Factored<br />

Resistance<br />

Ordering<br />

<br />

when width is<br />

<br />

<br />

100% of table value.<br />

<br />

on skews greater<br />

<br />

Add SK angle required,<br />

and right (R) or left (L),<br />

to product number.<br />

Ex. SUH210-SK45R<br />

<br />

100% of table value<br />

Add SL, slope required,<br />

and up (U) or down (D),<br />

to product number.<br />

Ex. SUH210-SL30D<br />

See Sloped Seat and Skewed<br />

80% of table value.<br />

<br />

on skews greater<br />

<br />

See Sloped Seat and Skewed.<br />

Ex. SUH210-SK45RSL30D<br />

ST<br />

W<br />

DT<br />

D<br />

H<br />

1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange.<br />

2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails.<br />

3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-Joists.<br />

4) Some SUH option hangers may be manufactured as welded products to achieve listed values.<br />

Typical JLIF<br />

installation<br />

<strong>Hangers</strong><br />

88<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

JLIF


Slant Nail Joist <strong>Hangers</strong> – HUS, JUS, & MUS series<br />

The HUS, JUS, & MUS hanger series offers double shear nailing. <strong>USP</strong>’s dimple allows for<br />

30° to 45° nailing through the joist into the header resulting in higher loads and less<br />

nailing. Slant nailing also eliminates the need for shorter joist nails in 2x applications.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: See chart<br />

Finish: G90 galvanizing; JUS24-GC, JUS26-GC, JUS28-GC, JUS210-GC,<br />

JUS26-2GC & JUS210-2GC – Gold Coat<br />

Options: HUS26, HUS28, HUS210, HUS28-2IF, HUS210-2IF, JUS24, JUS26,<br />

JUS24-2, JUS26-2, JUS28, JUS28-2, JUS210, JUS36, JUS210-2,<br />

JUS44, JUS46, JUS48, JUS410, JUS28-3 and JUS210-3 are available<br />

in Triple Zinc. To order, add TZ to stock number, as in JUS24-TZ.<br />

HUS212-2, JUS24, JUS26, JUS26-2, JUS28, JUS28-2, JUS210,<br />

JUS210-2, and JUS210-3 are available in Stainless Steel. To order, add<br />

SS to stock number, as in JUS26-SS.<br />

See HUS Specialty Options Chart.<br />

Codes: Load values are derived from data submitted to various North<br />

American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Joist nails must be driven at a 30° to 45° angle through the joist or truss into the<br />

header to achieve listed loads. Standard length “double shear” nails must be used to<br />

achieve listed load values.<br />

• JUS & MUS 16d sinkers (9 gauge x 31⁄4˝) may be used where 10d commons are<br />

specified with no load reduction.<br />

Dimple<br />

allows 30º<br />

to 45˚<br />

nailing<br />

Typical JUS46<br />

installation<br />

W<br />

JUS28<br />

A<br />

D<br />

H<br />

Double shear nail design<br />

features fewer nails and<br />

faster installation<br />

Uses standard<br />

length nails<br />

MUS<br />

HUS Specialty Options Chart –<br />

refer to Specialty Options pages<br />

210 to 211 for additional details.<br />

Option<br />

Range<br />

Factored<br />

Resistance<br />

Ordering<br />

Inverted Flange<br />

Not available in<br />

<br />

<br />

65% of table value when<br />

nailing into the support<br />

<br />

Add IF<br />

<br />

<br />

Typical HUS410IF<br />

inverted flange installation<br />

Typical HUS46<br />

installation<br />

HUS28-2<br />

<strong>Hangers</strong><br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 89<br />

<strong>USP</strong>2240-131


Heavy-Duty Face Mount <strong>Hangers</strong> – HD series<br />

HD hangers are heavy-duty face mount hangers that can be<br />

used to support headers, joists, and trusses.<br />

Materials: 14 gauge<br />

Finish: G90 galvanizing<br />

Options: HD28-2IF, HD210-2IF, HD210-3IF, HD44IF,<br />

HD46, HD46IF, HD48, HD48IF, HD410,<br />

HD410IF, HD412, HD412IF, HD68, HD68IF,<br />

HD610, HD610IF, HD612 & HD612IF are<br />

available in Triple Zinc. To order, add TZ to<br />

stock number, as in HD28-2IFTZ.<br />

HD210-2IF is available in Stainless Steel. To<br />

order, add SS to stock number,<br />

as in HD210-2IFSS.<br />

All nominal lumber sizes are available<br />

rough/full size lumber. See Specialty Options<br />

Chart.<br />

Codes: Load values are derived from data submitted to<br />

various North American building code<br />

evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Some HD models feature nail holes along bend line that must<br />

be filled to achieve factored resistance. Verify proper<br />

header width to accomplish this for inverted models.<br />

Typical HD610<br />

installation<br />

W<br />

Bend line<br />

nailing<br />

HD610<br />

A<br />

D<br />

H<br />

Typical HD210-2<br />

installation<br />

Drive bend line nails<br />

into header at 45°<br />

to achieve listed loads.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Specialty Options Chart – refer to Specialty Options<br />

pages 210 to 211 for additional details.<br />

Option 4 Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Inverted Flange<br />

Range<br />

Factored<br />

Resistance<br />

Ordering<br />

<br />

when width is<br />

<br />

<br />

100% of table value.<br />

75% of uplift value<br />

on skews greater<br />

<br />

Add SK, angle required,<br />

and right (R) or left (L),<br />

to product number.<br />

Ex. HD410-SK45R<br />

<br />

100% of table value<br />

Add SL, slope required,<br />

and up (U) or down (D),<br />

to product number.<br />

Ex. HD410-SL30D<br />

See Sloped Seat and<br />

Skewed<br />

80% of table value.<br />

75% of uplift value<br />

on skews greater<br />

<br />

See Sloped Seat and<br />

Skewed.<br />

Ex. HD410-SK45RSL30D<br />

Not available in<br />

<br />

100% of table value.<br />

65% of table value when<br />

nailing into the support<br />

members end grain.<br />

Add IF<br />

to product number.<br />

Ex. HD410IF<br />

1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange.<br />

2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails.<br />

3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-joists.<br />

4) Modifications of HD hangers may be manufactured as hot rolled, welded, or primed.<br />

Inverted Flange <strong>Hangers</strong> – HDQIF series<br />

HDQIF inverted flange hangers install with wood screws eliminating<br />

the need to drill bolt holes simplifying installation.<br />

Typical HD210-2IF<br />

inverted flange<br />

installation<br />

Typical HD3212<br />

glulam installation<br />

W<br />

A<br />

HD51135<br />

D<br />

H<br />

<strong>Hangers</strong><br />

Materials: 14 gauge<br />

Finish: G90 galvanizing<br />

Options: HDQ612IF is available in Stainless Steel. To order,<br />

add SS to stock number, as in HDQ612IF-SS.<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

H<br />

90<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• WS15 and WS3 Wood Screws are supplied with HDQIF hangers.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

W<br />

HDQIF<br />

3˝<br />

Up to<br />

3/4˝ gap<br />

Typical HDQIF<br />

installation


Face Mount Hanger Charts<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Dimensions (in) Fastener Schedule 2,3,4 Factored Resistance<br />

Header Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Joist Size Stock No. Ref. No. Gauge W H D A Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

2 x 4<br />

2 x 6<br />

2 x 8<br />

2 x 10<br />

2 x 12<br />

JL24 LU24, LU24L 20 1-9/16 3 1-1/2 15/16 4 10d 2 10d x 1-1/2 970 460 4.31 2.05 689 327 3.06 1.45<br />

ST24 -- -- 22 1-9/16 3-1/4 1-7/8 1-1/4 4 10d x 1-1/2 3 8d x 1-1/2 670 370 2.98 1.65 670 370 2.98 1.65<br />

JL24IF-TZ -- -- 18 1-9/16 3-1/8 1-1/2 -- -- 4 10d HDG 2 10d x 1-1/2 HDG 670 380 2.98 1.69 475 270 2.11 1.20<br />

JUS24 LUS24 18 1-9/16 3-1/8 1-3/4 1 4 10d 2 10d 1595 960 7.10 4.27 1132 682 5.04 3.03<br />

JUS24-GC -- -- 18 1-9/16 3-1/8 1-3/4 1 4 N10C-GC 2 N10C-GC 1595 960 7.10 4.27 1132 682 5.04 3.03<br />

SUH24 U24 16 1-9/16 3-1/4 2 1-3/16 4 10d 2 10d x 1-1/2 1390 795 6.18 3.54 985 565 4.38 2.51<br />

HD26 HU26 14 1-9/16 3-1/2 2 1-1/8 4 16d 2 10d x 1 1/2 1975 545 8.79 2.42 1402 387 6.24 1.72<br />

JL26 LU26, LU26L 20 1-9/16 4-3/4 1-1/2 15/16 6 10d 4 10d x 1-1/2 1430 915 6.36 4.07 1015 650 4.52 2.89<br />

ST26 -- -- 22 1-9/16 5 1-7/8 1-1/4 6 10d x 1-1/2 5 8d x 1-1/2 1000 620 4.45 2.76 1000 620 4.45 2.76<br />

JL26IF-TZ LUC26Z 18 1-9/16 4-1/2 1-1/2 -- -- 6 10d HDG 4 10d x 1-1/2 HDG 1000 755 4.45 3.36 710 535 3.16 2.38<br />

JUS26 LUS26 18 1-9/16 4-13/16 1-3/4 1 4 10d 4 10d 2855 2100 12.70 9.34 2027 1491 9.02 6.63<br />

JUS26-GC -- -- 18 1-9/16 4-13/16 1-3/4 1 4 N10C-GC 4 N10C-GC 2855 2100 12.70 9.34 2027 1491 9.02 6.63<br />

MUS26 MUS26 18 1-9/16 5-1/16 2 1 6 10d 6 10d 3245 1625 14.44 7.23 2305 1155 10.25 5.14<br />

SUH26 U26 16 1-9/16 5-1/8 2 1-3/16 6 10d 4 10d x 1-1/2 2345 1505 10.43 6.69 1665 1070 7.41 4.76<br />

HUS26 HUS26 16 1-5/8 5-7/16 3 2 14 16d 6 16d 5480 3625 24.38 16.13 3891 2574 17.31 11.45<br />

HD26 HU26 14 1-9/16 3-1/2 2 1-1/8 4 16d 2 10d x 1 1/2 1975 545 8.79 2.42 1402 387 6.24 1.72<br />

HD28 HU28 14 1-9/16 5-1/4 2 1-1/8 8 16d 4 10d x 1 1/2 2720 1555 12.10 6.92 1931 1104 8.59 4.91<br />

JL26 LU26, LU26L 20 1-9/16 4-3/4 1-1/2 15/16 6 10d 4 10d x 1-1/2 1430 915 6.36 4.07 1015 650 4.52 2.89<br />

JL28 LU28 20 1-9/16 6-3/8 1-1/2 15/16 10 10d 6 10d x 1-1/2 2120 1665 9.43 7.41 1505 1182 6.69 5.26<br />

ST26 -- -- 22 1-9/16 5 1-7/8 1-1/4 6 10d x 1-1/2 5 8d x 1-1/2 1000 620 4.45 2.76 1000 620 4.45 2.76<br />

ST28 -- -- 22 1-9/16 6-3/4 1-7/8 1-1/4 8 10d x 1-1/2 7 8d x 1-1/2 1340 870 5.96 3.87 1340 870 5.96 3.87<br />

JL26IF-TZ LUC26Z 18 1-9/16 4-1/2 1-1/2 -- -- 6 10d HDG 4 10d x 1-1/2 HDG 1000 755 4.45 3.36 710 535 3.16 2.38<br />

JL28IF-TZ -- -- 18 1-9/16 6-1/8 1-1/2 -- -- 8 10d HDG 4 10d x 1-1/2 HDG 1340 755 5.96 3.36 950 535 4.23 2.38<br />

JUS26 LUS26 18 1-9/16 4-13/16 1-3/4 1 4 10d 4 10d 2855 2100 12.70 9.34 2027 1491 9.02 6.63<br />

JUS26-GC -- -- 18 1-9/16 4-13/16 1-3/4 1 4 N10C-GC 4 N10C-GC 2855 2100 12.70 9.34 2027 1491 9.02 6.63<br />

JUS28 LUS28 18 1-9/16 6-5/8 1-3/4 1 6 10d 4 10d 2855 2100 12.70 9.34 2027 1491 9.02 6.63<br />

JUS28-GC -- -- 18 1-9/16 6-5/8 1-3/4 1 6 N10C-GC 4 N10C-GC 2855 2100 12.70 9.34 2027 1491 9.02 6.63<br />

MUS26 MUS26 18 1-9/16 5-1/16 2 1 6 10d 6 10d 3245 1625 14.44 7.23 2305 1155 10.25 5.14<br />

MUS28 MUS28 18 1-9/16 7-1/16 2 1 8 10d 8 10d 4400 2315 19.57 10.30 3125 1645 13.90 7.32<br />

SUH26 U26 16 1-9/16 5-1/8 2 1-3/16 6 10d 4 10d x 1 1/2 2345 1505 10.43 6.69 1665 1070 7.41 4.76<br />

SUH28 -- -- 16 1-9/16 6-5/8 2 1-3/16 8 10d 6 10d x 1 1/2 2345 1505 10.43 6.69 1665 1070 7.41 4.76<br />

HUS26 HUS26 16 1-5/8 5-7/16 3 2 14 16d 6 16d 5480 3625 24.38 16.13 3891 2574 17.31 11.45<br />

HUS28 HUS28 16 1-5/8 7-3/16 3 2 22 16d 8 16d 7115 4840 31.65 21.53 5052 3436 22.47 15.28<br />

HD28 HU28 14 1-9/16 5-1/4 2 1-1/8 8 16d 4 10d x 1 1/2 2720 1555 12.10 6.92 1931 1104 8.59 4.91<br />

HD210 HU210 14 1-9/16 7-3/16 2 1-1/8 12 16d 4 10d x 1 1/2 3820 1555 16.99 6.92 2712 1104 12.06 4.91<br />

JL28 LU28 20 1-9/16 6-3/8 1-1/2 15/16 10 10d 6 10d x 1-1/2 2120 1665 9.43 7.41 1505 1182 6.69 5.26<br />

JL210 LU210 20 1-9/16 8-1/4 1-1/2 15/16 14 10d 8 10d x 1-1/2 3070 2065 13.66 9.19 2180 1466 9.70 6.52<br />

ST28 -- -- 22 1-9/16 6-3/4 1-7/8 1-1/4 8 10d x 1-1/2 7 10d x 1-1/2 1340 870 5.96 3.87 1340 870 5.96 3.87<br />

ST210 -- -- 22 1-9/16 8 1-7/8 1-1/4 10 10d x 1-1/2 8 10d x 1-1/2 1520 990 6.76 4.40 1520 990 6.76 4.40<br />

JL28IF-TZ -- -- 18 1-9/16 6-1/8 1-1/2 -- -- 8 10d HDG 4 10d x 1-1/2 HDG 1340 755 5.96 3.36 950 535 4.23 2.38<br />

JL210IF-TZ LUC210Z 18 1-9/16 8-7/32 1-1/2 -- -- 11 10d HDG 6 10d x 1-1/2 HDG 1835 1135 8.16 5.05 1305 805 5.81 3.58<br />

JUS28 LUS28 18 1-9/16 6-5/8 1-3/4 1 6 10d 4 10d 2855 2100 12.70 9.34 2027 1491 9.02 6.63<br />

JUS28-GC -- -- 18 1-9/16 6-5/8 1-3/4 1 6 N10C-GC 4 N10C-GC 2855 2100 12.70 9.34 2027 1491 9.02 6.63<br />

JUS210 LUS210 18 1-9/16 7-3/4 1-3/4 1 8 10d 4 10d 2855 2100 12.70 9.34 2027 1491 9.02 6.63<br />

JUS210-GC -- -- 18 1-9/16 7-3/4 1-3/4 1 8 N10C-GC 4 N10C-GC 2855 2100 12.70 9.34 2027 1491 9.02 6.63<br />

MUS28 MUS28 18 1-9/16 7-1/16 2 1 8 10d 8 10d 4400 2315 19.57 10.30 3125 1645 13.90 7.32<br />

SUH28 -- -- 16 1-9/16 6-5/8 2 1-3/16 8 10d 6 10d x 1-1/2 2345 1505 10.43 6.69 1665 1070 7.41 4.76<br />

SUH210 U210 16 1-9/16 8 2 1-3/16 10 10d 6 10d x 1-1/2 4080 2505 18.15 11.14 2895 1780 12.88 7.92<br />

HUS28 HUS28 16 1-5/8 7-3/16 3 2 22 16d 8 16d 7115 4840 31.65 21.53 5052 3436 22.47 15.28<br />

HUS210 HUS210 16 1-5/8 9-3/16 3 2 30 16d 10 16d 9025 6035 40.15 26.85 6408 4285 28.51 19.06<br />

HD210 HU210 14 1-9/16 7-3/16 2 1-1/8 12 16d 4 10d x 1 1/2 3820 1555 16.99 6.92 2712 1104 12.06 4.91<br />

JL210 LU210, LU210L 20 1-9/16 8-1/4 1-1/2 15/16 14 10d 8 10d x 1-1/2 3070 2065 13.66 9.19 2180 1466 9.70 6.52<br />

ST210 -- -- 22 1-9/16 8 1-7/8 1-1/4 10 10d x 1-1/2 8 8d x 1-1/2 1520 990 6.76 4.40 1520 990 6.76 4.40<br />

JL210IF-TZ LUC210Z 18 1-9/16 8-7/32 1-1/2 -- -- 11 10d HDG 6 10d x 1-1/2 HDG 1835 1135 8.16 5.05 1305 805 5.81 3.58<br />

JUS210 LUS210 18 1-9/16 7-3/4 1-3/4 1 8 10d 4 10d 2855 2100 12.70 9.34 2027 1491 9.02 6.63<br />

JUS210-GC -- -- 18 1-9/16 7-3/4 1-3/4 1 8 N10C-GC 4 N10C-GC 2855 2100 12.70 9.34 2027 1491 9.02 6.63<br />

SUH210 U210 16 1-9/16 8 2 1-3/16 10 10d 6 10d x 1-1/2 4080 2505 18.15 11.14 2895 1780 12.88 7.92<br />

HUS210 HUS210 16 1-5/8 9-3/16 3 2 30 16d 10 16d 9025 6035 40.15 26.85 6408 4285 28.51 19.06<br />

HD210 HU210 14 1-9/16 7-3/16 2 1-1/8 12 16d 4 10d x 1 1/2 3820 1555 16.99 6.92 2712 1104 12.06 4.91<br />

HD212 HU212 14 1-9/16 9-1/4 2 1-1/8 16 16d 6 10d x 1 1/2 4545 2005 20.22 8.92 3227 1424 14.35 6.33<br />

HD212IF HUC212 14 1-9/16 9-1/4 2 -- -- 16 16d 6 10d x 1 1/2 4545 2005 20.22 8.92 3227 1424 14.35 6.33<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) 16d sinkers may be used at 0.84 of the table load where 16d commons are specified.<br />

4) NAILS:<br />

red font.<br />

<strong>Hangers</strong><br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 91<br />

<strong>USP</strong>2240-131


Face Mount Hanger Charts continued<br />

<strong>Hangers</strong><br />

92<br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Joist Size Stock No. Ref. No. Gauge W H D A Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

2 x 14<br />

2 x 16<br />

(2) 2 x 4<br />

(2) 2 x 6<br />

(2) 2 x 8<br />

(2) 2 x 10<br />

(2) 2 x 12<br />

Dimensions (in) Fastener Schedule 2,3,4 Factored Resistance<br />

Header Joist DF-L (Lbs) DF-L (kN)<br />

SUH214 U214 16 1-9/16 10 2 1-1/8 12 10d 8 10d x 1-1/2 4105 2505 18.26 11.14 2915 1780 12.97 7.92<br />

HD212 HU212 14 1-9/16 9-1/4 2 1-1/8 16 16d 6 10d x 1 1/2 4545 2005 20.22 8.92 3227 1424 14.35 6.33<br />

HD212IF HUC212 14 1-9/16 9-1/4 2 -- -- 16 16d 6 10d x 1 1/2 4545 2005 20.22 8.92 3227 1424 14.35 6.33<br />

HD214 HU214 14 1-9/16 11-1/2 2 1-1/8 20 16d 6 10d x 1-1/2 5915 2005 26.31 8.92 4200 1425 18.68 6.34<br />

SUH214 U214 16 1-9/16 10 2 1-1/8 12 10d 8 10d x 1-1/2 4105 2505 18.26 11.14 2915 1780 12.97 7.92<br />

HD212 HU212 14 1-9/16 9-1/4 2 1-1/8 16 16d 6 10d x 1 1/2 4545 2005 20.22 8.92 3227 1424 14.35 6.33<br />

HD212IF HUC212 14 1-9/16 9-1/4 2 -- -- 16 16d 6 10d x 1 1/2 4545 2005 20.22 8.92 3227 1424 14.35 6.33<br />

HD214 HU214 14 1-9/16 11-1/2 2 1-1/8 20 16d 6 10d x 1-1/2 5915 2005 26.31 8.92 4200 1425 18.68 6.34<br />

HD216 HU216 14 1-9/16 13-1/2 2 1-1/8 24 16d 8 10d x 1-1/2 5915 2005 26.31 8.92 4200 1425 18.68 6.34<br />

JUS24-2 LUS24-2 18 3-1/8 3-7/16 2 1 4 16d 2 16d 1580 610 7.03 2.71 1122 433 4.99 1.93<br />

SUH24-2 U24-2 16 3-1/8 3-1/8 2 1-1/8 6 10d 2 10d 1910 825 8.50 3.67 1355 585 6.03 2.60<br />

HD24-2 HU24-2 14 3-1/8 3-1/2 2-1/2 1-1/8 4 16d 2 10d 1535 535 6.83 2.38 1090 380 4.85 1.69<br />

HUS24-2 -- -- 14 3-1/8 3-7/16 2 1 4 16d 2 16d 2130 935 9.48 4.16 1512 664 6.73 2.95<br />

HUS24-2IF -- -- 14 3-1/8 3-7/16 2 1 4 16d 2 16d 2130 935 9.48 4.16 1512 664 6.73 2.95<br />

DT26 -- -- 22 3-1/16 5 2 1-1/4 8 16d x 2-1/2 5 8d x 1-1/2 1380 620 6.14 2.76 1380 620 6.14 2.76<br />

JUS26-2 LUS26-2 18 3-1/8 5-1/4 2 1 4 16d 4 16d 2000 2550 8.90 11.34 1420 1811 6.32 8.06<br />

JUS26-2GC -- -- 18 3-1/8 5-1/4 2 1 4 N16C-GC 4 N16C-GC 2000 2550 8.90 11.34 1420 1811 6.32 8.06<br />

SUH26-2 U26-2 16 3-1/8 5-1/16 2 1-1/8 8 10d 4 10d 3135 1665 13.95 7.41 2225 1180 9.90 5.25<br />

HD24-2 HU24-2 14 3-1/8 3-1/2 2-1/2 1-1/8 4 16d 2 10d 1535 535 6.83 2.38 1090 380 4.85 1.69<br />

HUS26-2 HUS26-2 14 3-1/8 5-1/4 2 1 4 16d 4 16d 2130 2095 9.48 9.32 1512 1487 6.73 6.61<br />

HUS26-2IF HUSC26-2 14 3-1/8 5-1/4 2 -- -- 4 16d 4 16d 2130 2095 9.48 9.32 1512 1487 6.73 6.61<br />

HD26-2 HU26-2 14 3-1/8 5-1/8 2-1/2 1-1/8 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

HD26-2IF HUC26-2 14 3-1/8 5-1/8 2-1/2 1-1/8 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

DT26 -- -- 22 3-1/16 5 2 1-1/4 8 16d x 2-1/2 5 8d x 1-1/2 1380 620 6.14 2.76 1380 620 6.14 2.76<br />

DT28 -- -- 22 3-1/16 6-3/4 2 1-1/4 10 16d x 2-1/2 7 8d x 1-1/2 1510 870 6.72 3.87 1510 870 6.72 3.87<br />

JUS26-2 LUS26-2 18 3-1/8 5-1/4 2 1 4 16d 4 16d 2000 2550 8.90 11.34 1420 1811 6.32 8.06<br />

JUS26-2GC -- -- 18 3-1/8 5-1/4 2 1 4 N16C-GC 4 N16C-GC 2000 2550 8.90 11.34 1420 1811 6.32 8.06<br />

JUS28-2 LUS28-2 18 3-1/8 7-1/8 2 1 6 16d 4 16d 3240 2550 14.41 11.34 2300 1811 10.23 8.06<br />

SUH26-2 U26-2 16 3-1/8 5-1/16 2 1-1/8 8 10d 4 10d 3135 1665 13.95 7.41 2225 1180 9.90 5.25<br />

SUH28-2 -- -- 16 3-1/8 6-1/4 2 1-1/8 10 10d 4 10d 3135 1665 13.95 7.41 2225 1180 9.90 5.25<br />

HUS26-2 HUS26-2 14 3-1/8 5-1/4 2 1 4 16d 4 16d 2130 2095 9.48 9.32 1512 1487 6.73 6.61<br />

HUS26-2IF HUSC26-2 14 3-1/8 5-1/4 2 -- -- 4 16d 4 16d 2130 2095 9.48 9.32 1512 1487 6.73 6.61<br />

HUS28-2 HUS28-2 14 3-1/8 7-1/8 2 1 6 16d 6 16d 3795 3405 16.88 15.15 2694 2418 11.98 10.76<br />

HUS28-2IF HUSC28-2 14 3-1/8 7-1/8 2 -- -- 6 16d 6 16d 3795 3405 16.88 15.15 2694 2418 11.98 10.76<br />

HD26-2 HU26-2 14 3-1/8 5-1/8 2-1/2 1-1/8 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

HD26-2IF HUC26-2 14 3-1/8 5-1/8 2-1/2 1-1/8 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

HD28-2 HU28-2 14 3-1/8 7-1/8 2-1/2 1-1/8 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HD28-2IF HUC28-2 14 3-1/8 7-1/8 2-1/2 -- -- 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

DT28 -- -- 22 3-1/16 6-3/4 2 1-1/4 10 16d x 2-1/2 7 8d x 1-1/2 1510 870 6.72 3.87 1510 870 6.72 3.87<br />

DT210 -- -- 22 3-1/16 7-7/8 2 1-1/4 12 16d x 2-1/2 8 8d x 1-1/2 1640 990 7.30 4.40 1640 990 7.30 4.40<br />

JUS28-2 LUS28-2 18 3-1/8 7-1/8 2 1 6 16d 4 16d 3240 2550 14.41 11.34 2300 1811 10.23 8.06<br />

JUS210-2 LUS210-2 18 3-1/8 9-1/8 2 1 8 16d 6 16d 5170 3735 23.00 16.61 3671 2652 16.33 11.80<br />

JUS210-2GC -- -- 18 3-1/8 9-1/8 2 1 8 N16C-GC 6 N16C-GC 5170 3735 23.00 16.61 3671 2652 16.33 11.80<br />

SUH28-2 -- -- 16 3-1/8 6-1/4 2 1-1/8 10 10d 4 10d 3135 1665 13.95 7.41 2225 1180 9.90 5.25<br />

SUH210-2 U210-2 16 3-1/8 8-9/16 2 1-1/8 14 10d 6 10d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

HUS28-2 HUS28-2 14 3-1/8 7-1/8 2 1 6 16d 6 16d 3795 3405 16.88 15.15 2694 2418 11.98 10.76<br />

HUS28-2IF HUSC28-2 14 3-1/8 7-1/8 2 -- -- 6 16d 6 16d 3795 3405 16.88 15.15 2694 2418 11.98 10.76<br />

HD28-2 HU28-2 14 3-1/8 7-1/8 2-1/2 1-1/8 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HD28-2IF HUC28-2 14 3-1/8 7-1/8 2-1/2 -- -- 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HUS210-2 HUS210-2 14 3-1/8 9-1/8 2 1 8 16d 8 16d 5185 4165 23.06 18.53 3681 2957 16.37 13.15<br />

HUS210-2IF HUSC210-2 14 3-1/8 9-1/8 2 -- -- 8 16d 8 16d 5185 4165 23.06 18.53 3681 2957 16.37 13.15<br />

HD210-2 HU210-2 14 3-1/8 9 2-1/2 1-1/8 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD210-2IF HUC210-2 14 3-1/8 9 2-1/2 -- -- 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ210-2IF HUCQ210-2-SDS 14 3-1/4 9 3 1-1/2 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

DT210 -- -- 22 3-1/16 7-7/8 2 1-1/4 12 16d x 2-1/2 8 8d x 1-1/2 1640 990 7.30 4.40 1640 990 7.30 4.40<br />

JUS210-2 LUS210-2 18 3-1/8 9-1/8 2 1 8 16d 6 16d 5170 3735 23.00 16.61 3671 2652 16.33 11.80<br />

JUS210-2GC -- -- 18 3-1/8 9-1/8 2 1 8 N16C-GC 6 N16C-GC 5170 3735 23.00 16.61 3671 2652 16.33 11.80<br />

SUH210-2 U210-2 16 3-1/8 8-9/16 2 1-1/8 14 10d 6 10d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

HUS210-2 HUS210-2 14 3-1/8 9-1/8 2 1 8 16d 8 16d 5185 4165 23.06 18.53 3681 2957 16.37 13.15<br />

HUS210-2IF HUSC210-2 14 3-1/8 9-1/8 2 -- -- 8 16d 8 16d 5185 4165 23.06 18.53 3681 2957 16.37 13.15<br />

HD210-2 HU210-2 14 3-1/8 9 2-1/2 1-1/8 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD210-2IF HUC210-2 14 3-1/8 9 2-1/2 -- -- 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HUS212-2 HUS212-2 14 3-1/8 11-1/8 2 1 10 16d 10 16d 6345 5765 28.23 25.65 4505 4093 20.04 18.21<br />

HUS212-2IF HUSC212-2 14 3-1/8 11-1/8 2 -- -- 10 16d 10 16d 6345 5765 28.23 25.65 4505 4093 20.04 18.21<br />

HD212-2 HU212-2 14 3-1/8 11 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD212-2IF HUC212-2 14 3-1/8 11 2-1/2 -- -- 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ210-2IF HUCQ210-2-SDS 14 3-1/4 9 3 1-1/2 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) 16d sinkers may be used at 0.84 of the table load where 16d commons are specified.<br />

4) NAILS:<br />

red font.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

S-P-F (Lbs)<br />

S-P-F (kN)<br />

continued on next page<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®


Face Mount Hanger Charts continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Joist Size Stock No. Ref. No. Gauge W H D A Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

(2) 2 x 14<br />

(2) 2 x 16<br />

3 x 4<br />

3 x 6<br />

3 x 8<br />

3 x 10<br />

3 x 12<br />

3 x 14<br />

3 x 16<br />

Dimensions (in)<br />

Fastener Schedule 2,3,4,5<br />

Factored Resistance<br />

Header Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

JUS210-2 LUS210-2 18 3-1/8 9-1/8 2 1 8 16d 6 16d 5170 3735 23.00 16.61 3671 2652 16.33 11.80<br />

JUS210-2GC -- -- 18 3-1/8 9-1/8 2 1 8 N16C-GC 6 N16C-GC 5170 3735 23.00 16.61 3671 2652 16.33 11.80<br />

JUS214-2 LUS214-2 18 3-1/8 13-1/8 2 1 12 16d 6 16d 5120 3735 22.78 16.61 3635 2650 16.17 11.79<br />

SUH210-2 U210-2 16 3-1/8 8-9/16 2 1-1/8 14 10d 6 10d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

HUS210-2 HUS210-2 14 3-1/8 9-1/8 2 1 8 16d 8 16d 5185 4165 23.06 18.53 3681 2957 16.37 13.15<br />

HUS210-2IF HUSC210-2 14 3-1/8 9-1/8 2 -- -- 8 16d 8 16d 5185 4165 23.06 18.53 3681 2957 16.37 13.15<br />

HD210-2 HU210-2 14 3-1/8 9 2-1/2 1-1/8 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD210-2IF HUC210-2 14 3-1/8 9 2-1/2 -- -- 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HUS212-2 HUS212-2 14 3-1/8 11-1/8 2 1 10 16d 10 16d 6345 5765 28.23 25.65 4505 4093 20.04 18.21<br />

HUS212-2IF HUSC212-2 14 3-1/8 11-1/8 2 -- -- 10 16d 10 16d 6345 5765 28.23 25.65 4505 4093 20.04 18.21<br />

HD212-2 HU212-2 14 3-1/8 11 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD212-2IF HUC212-2 14 3-1/8 11 2-1/2 -- -- 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD214-2 HU214-2 14 3-1/8 13 2-1/2 1-1/8 24 16d 10 10d 7215 4435 32.10 19.73 5125 3150 22.80 14.01<br />

HDQ210-2IF HUCQ210-2-SDS 14 3-1/4 9 3 1-1/2 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

JUS214-2 LUS214-2 18 3-1/8 13-1/8 2 1 12 16d 6 16d 5120 3735 22.78 16.61 3635 2650 16.17 11.79<br />

HD212-2 HU212-2 14 3-1/8 11 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD212-2IF HUC212-2 14 3-1/8 11 2-1/2 -- -- 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD214-2 HU214-2 14 3-1/8 13 2-1/2 1-1/8 24 16d 10 10d 7215 4435 32.10 19.73 5125 3150 22.80 14.01<br />

HD216-2 HU216-2 14 3-1/8 15 2-1/2 1-1/8 26 16d 12 10d 7215 4435 32.10 19.73 5125 3150 22.80 14.01<br />

SUH34 U34 16 2-9/16 3-3/8 2 1-1/8 6 10d 2 10d x 1 1/2 1390 795 6.18 3.54 985 565 4.38 2.51<br />

HD34 HU34 14 2-9/16 3 2 1-1/8 4 16d 2 10d x 1 1/2 1975 545 8.79 2.42 1402 387 6.24 1.72<br />

HD34IF HUC34 14 2-9/16 3 2 -- -- 4 16d 2 10d x 1 1/2 1975 545 8.79 2.42 1402 387 6.24 1.72<br />

JUS36 LUS36 18 2-9/16 5-5/16 2 1 4 16d 4 16d 2000 2550 8.90 11.34 1420 1810 6.32 8.05<br />

SUH34 U34 16 2-9/16 3-3/8 2 1-1/8 6 10d 2 10d x 1 1/2 1390 795 6.18 3.54 985 565 4.38 2.51<br />

SUH36 U36 16 2-9/16 5-5/16 2 1-1/8 8 10d 4 10d x 1 1/2 2345 1505 10.43 6.69 1665 1070 7.41 4.76<br />

HD36 HU36 14 2-9/16 4-3/4 2 1-1/8 8 16d 4 10d x 1 1/2 2720 1555 12.10 6.92 1931 1104 8.59 4.91<br />

HD36IF HUC36 14 2-9/16 4-3/4 2 -- -- 8 16d 4 10d x 1 1/2 2720 1555 12.10 6.92 1931 1104 8.59 4.91<br />

JUS36 LUS36 18 2-9/16 5-5/16 2 1 4 16d 4 16d 2000 2550 8.90 11.34 1420 1810 6.32 8.05<br />

JUS38 -- -- 18 2-9/16 6-3/4 2 1 6 16d 4 16d 3240 2550 14.41 11.34 2300 1810 10.23 8.05<br />

SUH36 U36 16 2-9/16 5-5/16 2 1-1/8 8 10d 4 10d x 1 1/2 2345 1505 10.43 6.69 1665 1070 7.41 4.76<br />

HD36 HU36 14 2-9/16 4-3/4 2 1-1/8 8 16d 4 10d x 1 1/2 2720 1555 12.10 6.92 1931 1104 8.59 4.91<br />

HD36IF HUC36 14 2-9/16 4-3/4 2 -- -- 8 16d 4 10d x 1 1/2 2720 1555 12.10 6.92 1931 1104 8.59 4.91<br />

HD38 HU38 14 2-9/16 6-3/4 2 1-1/8 12 16d 4 10d x 1 1/2 3820 1555 16.99 6.92 2712 1104 12.06 4.91<br />

HD38IF HUC38 14 2-9/16 6-3/4 2 -- -- 12 16d 4 10d x 1 1/2 3820 1555 16.99 6.92 2712 1104 12.06 4.91<br />

JUS38 -- -- 18 2-9/16 6-3/4 2 1 6 16d 4 16d 3240 2550 14.41 11.34 2300 1810 10.23 8.05<br />

JUS310 LUS310 18 2-9/16 9-1/8 2 1 8 16d 6 16d 5170 3735 23.00 16.61 3671 2652 16.33 11.80<br />

SUH310 U310 16 2-9/16 8-7/8 2 1-1/8 14 10d 6 10d x 1 1/2 4080 2505 18.15 11.14 2895 1780 12.88 7.92<br />

HD38 HU38 14 2-9/16 6-3/4 2 1-1/8 12 16d 4 10d x 1 1/2 3820 1555 16.99 6.92 2712 1104 12.06 4.91<br />

HD38IF HUC38 14 2-9/16 6-3/4 2 -- -- 12 16d 4 10d x 1 1/2 3820 1555 16.99 6.92 2712 1104 12.06 4.91<br />

HD310 HU310 14 2-9/16 7-7/16 2-1/2 1-1/8 14 16d 6 10d x 1 1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

HD310IF HUC310 14 2-9/16 7-7/16 2-1/2 -- -- 14 16d 6 10d x 1 1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

HDQ310IF HUCQ310-SDS 14 2-9/16 9 3 1-3/16 8 WS3 4 WS15 5315 3025 23.64 13.46 3775 2150 16.79 9.56<br />

JUS310 LUS310 18 2-9/16 9-1/8 2 1 8 16d 6 16d 5170 3735 23.00 16.61 3671 2652 16.33 11.80<br />

SUH310 U310 16 2-9/16 8-7/8 2 1-1/8 14 10d 6 10d x 1 1/2 4080 2505 18.15 11.14 2895 1780 12.88 7.92<br />

HD38 HU38 14 2-9/16 6-3/4 2 1-1/8 12 16d 4 10d x 1 1/2 3820 1555 16.99 6.92 2712 1104 12.06 4.91<br />

HD38IF HUC38 14 2-9/16 6-3/4 2 -- -- 12 16d 4 10d x 1 1/2 3820 1555 16.99 6.92 2712 1104 12.06 4.91<br />

HD310 HU310 14 2-9/16 7-7/16 2-1/2 1-1/8 14 16d 6 10d x 1 1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

HD310IF HUC310 14 2-9/16 7-7/16 2-1/2 -- -- 14 16d 6 10d x 1 1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

HDQ310IF HUCQ310-SDS 14 2-9/16 9 3 1-3/16 8 WS3 4 WS15 5315 3025 23.64 13.46 3775 2150 16.79 9.56<br />

HD312 HU312 14 2-9/16 9-5/16 2-1/2 1-1/8 16 16d 10 10d x 1 1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

SUH314 U314 16 2-9/16 10-9/16 2 1-1/8 16 10d 6 10d x 1-1/2 4105 2505 18.26 11.14 2915 1780 12.97 7.92<br />

HD310 HU310 14 2-9/16 7-7/16 2-1/2 1-1/8 14 16d 6 10d x 1 1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

HD310IF HUC310 14 2-9/16 7-7/16 2-1/2 -- -- 14 16d 6 10d x 1 1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

HDQ310IF HUCQ310-SDS 14 2-9/16 9 3 1-3/16 8 WS3 4 WS15 5315 3025 23.64 13.46 3775 2150 16.79 9.56<br />

HD312 HU312 14 2-9/16 9-5/16 2-1/2 1-1/8 16 16d 10 10d x 1 1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

HD312IF HUC312 14 2-9/16 9-5/16 2-1/2 -- -- 16 16d 10 10d x 1 1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

HD314 HU314 14 2-9/16 11-5/16 2-1/2 1-1/8 20 16d 10 10d x 1-1/2 7215 2005 32.10 8.92 5125 1425 22.80 6.34<br />

HD314IF HUC314 14 2-9/16 11-5/16 2-1/2 -- -- 20 16d 10 10d x 1-1/2 7215 2005 32.10 8.92 5125 1425 22.80 6.34<br />

SUH314 U314 16 2-9/16 10-9/16 2 1-1/8 16 10d 6 10d x 1-1/2 4105 2505 18.26 11.14 2915 1780 12.97 7.92<br />

HD312 HU312 14 2-9/16 9-5/16 2-1/2 1-1/8 16 16d 10 10d x 1 1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

HD312IF HUC312 14 2-9/16 9-5/16 2-1/2 -- -- 16 16d 10 10d x 1 1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

HD314 HU314 14 2-9/16 11-5/16 2-1/2 1-1/8 20 16d 10 10d x 1-1/2 7215 2005 32.10 8.92 5125 1425 22.80 6.34<br />

HD314IF HUC314 14 2-9/16 11-5/16 2-1/2 -- -- 20 16d 10 10d x 1-1/2 7215 2005 32.10 8.92 5125 1425 22.80 6.34<br />

HD316 HU316 14 2-9/16 13-5/16 2-1/2 1-1/8 24 16d 10 10d x 1 1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

HD316IF HUC316 14 2-9/16 13-5/16 2-1/2 -- -- 24 16d 10 10d x 1 1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) 16d sinkers may be used at 0.84 of the table load where 16d commons are specified.<br />

<br />

5) NAILS:<br />

red font.<br />

<strong>Hangers</strong><br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 93<br />

<strong>USP</strong>2240-131


Face Mount Hanger Charts continued<br />

<strong>Hangers</strong><br />

Dimensions (in)<br />

Fastener Schedule 2,3,4,5<br />

Header<br />

Joist<br />

DF-L (Lbs)<br />

Factored Resistance<br />

S-P-F (Lbs)<br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Joist Size Stock No. Ref. No. Gauge W H D A Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

(2) 3 x 8 HD38-2 HU38-2 14 5-1/8 6-1/8 2-1/2 1-1/8 14 16d 6 10d 4675 2685 20.80 11.94 3320 1905 14.77 8.47<br />

(2) 3 x 10<br />

HD38-2 HU38-2 14 5-1/8 6-1/8 2-1/2 1-1/8 14 16d 6 10d 4675 2685 20.80 11.94 3320 1905 14.77 8.47<br />

HD310-2 HU310-2 14 5-1/8 8 2-1/2 1-1/8 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

(2) 3 x 12 HD312-2 HU312-2 14 5-1/8 10 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5125 3150 22.80 14.01<br />

(2) 3 x 14 HD312-2 HU312-2 14 5-1/8 10 2-1/2 1-1/8 16d 10 10d 7215 4435 32.10 19.73 5125 3150 22.80 14.01<br />

JUS26-3 LUS26-3 18 4-5/8 4-1/2 2 1 4 16d 4 16d 2000 2550 8.90 11.34 1420 1811 6.32 8.06<br />

(3) 2 x 6<br />

SUH26-3 U26-3 16 4-5/8 5-1/4 2 1 8 10d 2 10d 3135 1665 13.95 7.41 2225 1180 9.90 5.25<br />

HD26-3 HU26-3 14 4-5/8 4-3/8 2-1/2 1-1/8 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

HD26-3IF HUC26-3 14 4-5/8 4-3/8 2-1/2 -- -- 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

JUS26-3 LUS26-3 18 4-5/8 4-1/2 2 1 4 16d 4 16d 2000 2550 8.90 11.34 1420 1811 6.32 8.06<br />

JUS28-3 LUS28-3 18 4-5/8 6-3/8 2 1 6 16d 4 16d 3240 2550 14.41 11.34 2300 1811 10.23 8.06<br />

SUH26-3 U26-3 16 4-5/8 5-1/4 2 1 8 10d 2 10d 3135 1665 13.95 7.41 2225 1180 9.90 5.25<br />

(3) 2 x 8 HD26-3 HU26-3 14 4-5/8 4-3/8 2-1/2 1-1/8 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

HD26-3IF HUC26-3 14 4-5/8 4-3/8 2-1/2 -- -- 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

HD28-3 -- -- 14 4-5/8 6-3/8 2-1/2 1-1/8 12 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HD28-3IF -- -- 14 4-5/8 6-3/8 2-1/2 -- -- 12 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

JUS28-3 LUS28-3 18 4-5/8 6-3/8 2 1 6 16d 4 16d 3240 2550 14.41 11.34 2300 1811 10.23 8.06<br />

JUS210-3 LUS210-3 18 4-5/8 8-3/8 2 1 8 16d 6 16d 5170 3735 23.00 16.61 3671 2652 16.33 11.80<br />

SUH210-3 U210-3 16 4-5/8 8-3/8 2 1 14 10d 6 10d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

(3) 2 x 10<br />

HD28-3 -- -- 14 4-5/8 6-3/8 2-1/2 1-1/8 12 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HD28-3IF -- -- 14 4-5/8 6-3/8 2-1/2 -- -- 12 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HD210-3 HU210-3 14 4-5/8 8-1/4 2-1/2 1-1/8 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD210-3IF HUC210-3 14 4-5/8 8-1/4 2-1/2 -- -- 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ210-3IF HUCQ210-3-SDS 14 4-5/8 9 3 1-1/2 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

JUS210-3 LUS210-3 18 4-5/8 8-3/8 2 1 8 16d 6 16d 5170 3735 23.00 16.61 3671 2652 16.33 11.80<br />

SUH210-3 U210-3 16 4-5/8 8-3/8 2 1 14 10d 6 10d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

HD210-3 HU210-3 14 4-5/8 8-1/4 2-1/2 1-1/8 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

(3) 2 x 12 HD210-3IF HUC210-3 14 4-5/8 8-1/4 2-1/2 -- -- 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ210-3IF HUCQ210-3-SDS 14 4-5/8 9 3 1-1/2 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

HD212-3 HU212-3 14 4-5/8 10-1/4 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD212-3IF HUC212-3 14 4-5/8 10-1/4 2-1/2 -- -- 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

JUS210-3 LUS210-3 18 4-5/8 8-3/8 2 1 8 16d 6 16d 5170 3735 23.00 16.61 3671 2652 16.33 11.80<br />

SUH210-3 U210-3 16 4-5/8 8-3/8 2 1 14 10d 6 10d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

HD210-3 HU210-3 14 4-5/8 8-1/4 2-1/2 1-1/8 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

(3) 2 x 14<br />

HD210-3IF HUC210-3 14 4-5/8 8-1/4 2-1/2 -- -- 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ210-3IF HUCQ210-3-SDS 14 4-5/8 9 3 1-1/2 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

HD212-3 HU212-3 14 4-5/8 10-1/4 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD212-3IF HUC212-3 14 4-5/8 10-1/4 2-1/2 -- -- 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD214-3 HU214-3 14 4-5/8 12-1/4 2-1/2 1-1/8 24 16d 10 10d 7215 4435 32.10 19.73 5125 3150 22.80 14.01<br />

HD212-3 HU212-3 14 4-5/8 10-1/4 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

(3) 2 x 16<br />

HD212-3IF HUC212-3 14 4-5/8 10-1/4 2-1/2 -- -- 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD214-3 HU214-3 14 4-5/8 12-1/4 2-1/2 1-1/8 24 16d 10 10d 7215 4435 32.10 19.73 5125 3150 22.80 14.01<br />

HD216-3 HU216-3 14 4-5/8 14-1/4 2-1/2 1-1/8 26 16d 12 10d 7215 4435 32.10 19.73 5125 3150 22.80 14.01<br />

(4) 2 x 8 HD28-4 HU28-4 14 6-1/8 7-1/8 2-1/2 1-3/4 14 16d 6 10d 4675 2685 20.80 11.94 3320 1905 14.77 8.47<br />

(4) 2 x 10 HD210-4 HU210-4 14 6-1/8 9 3-1/4 2 24 16d 6 10d 7215 4435 32.10 19.73 5125 3150 22.80 14.01<br />

(4) 2 x 12 HD210-4 HU210-4 14 6-1/8 9 3-1/4 2 24 16d 6 10d 7215 4435 32.10 19.73 5125 3150 22.80 14.01<br />

(4) 2 x 14 HD210-4 HU210-4 14 6-1/8 9 3-1/4 2 24 16d 6 10d 7215 4435 32.10 19.73 5125 3150 22.80 14.01<br />

JUS44 LUS44 18 3-5/8 3-1/4 2 1 4 16d 2 16d 1580 610 7.03 2.71 1122 433 4.99 1.93<br />

4 x 4<br />

SUH44 U44 16 3-9/16 2-7/8 2 1-1/8 6 10d 2 10d 1910 825 8.50 3.67 1355 585 6.03 2.60<br />

HD44 HU44 14 3-9/16 3-5/16 2-1/2 1-1/8 4 16d 2 10d 1535 535 6.83 2.38 1090 380 4.85 1.69<br />

HD44IF HUC44 14 3-9/16 3-5/16 2-1/2 -- -- 4 16d 2 10d 1535 535 6.83 2.38 1090 380 4.85 1.69<br />

JUS46 LUS46 18 3-5/8 5 2 1 4 16d 4 16d 2000 2550 8.90 11.34 1420 1811 6.32 8.06<br />

SUH44 U44 16 3-9/16 2-7/8 2 1-1/8 6 10d 2 10d 1910 825 8.50 3.67 1355 585 6.03 2.60<br />

SUH46 U46 16 3-9/16 4-13/16 2 1-1/8 8 10d 4 10d 3135 1665 13.95 7.41 2225 1180 9.90 5.25<br />

4 x 6<br />

HUS46 HUS46 14 3-5/8 5 2 1 4 16d 4 16d 2130 2095 9.48 9.32 1512 1487 6.73 6.61<br />

HUS46IF HUSC46 14 3-5/8 5 2 -- -- 4 16d 4 16d 2130 2095 9.48 9.32 1512 1487 6.73 6.61<br />

HD46 HU46 14 3-9/16 4-15/16 2-1/2 1-1/8 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

HD46IF HUC46 14 3-9/16 4-15/16 2-1/2 -- -- 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

DF-L (kN)<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) 16d sinkers may be used at 0.84 of the table load where 16d commons are specified.<br />

<br />

5) NAILS:<br />

red font.<br />

S-P-F (kN)<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

94<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

continued on next page


Face Mount Hanger Charts continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Joist Size Stock No. Ref. No. Gauge W H D A Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Dimensions (in)<br />

Fastener Schedule 2,3,4,5<br />

Header<br />

Joist<br />

Factored Resistance<br />

DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

JUS46 LUS46 18 3-5/8 5 2 1 4 16d 4 16d 2000 2550 8.90 11.34 1420 1811 6.32 8.06<br />

JUS48 LUS48, LUS48Z 18 3-5/8 6-7/8 2 1 6 16d 4 16d 3240 2550 14.41 11.34 2300 1811 10.23 8.06<br />

SUH46 U46 16 3-9/16 4-13/16 2 1-1/8 8 10d 4 10d 3135 1665 13.95 7.41 2225 1180 9.90 5.25<br />

HUS46 HUS46 14 3-5/8 5 2 1 4 16d 4 16d 2130 2095 9.48 9.32 1512 1487 6.73 6.61<br />

HUS46IF HUSC46 14 3-5/8 5 2 -- -- 4 16d 4 16d 2130 2095 9.48 9.32 1512 1487 6.73 6.61<br />

HUS48 HUS48 14 3-5/8 7 2 1 6 16d 6 16d 3795 3405 16.88 15.15 2694 2418 11.98 10.76<br />

HUS48IF HUSC48 14 3-5/8 7 2 1 6 16d 6 16d 3795 3405 16.88 15.15 2694 2418 11.98 10.76<br />

HD46 HU46 14 3-9/16 4-15/16 2-1/2 1-1/8 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

HD46IF HUC46 14 3-9/16 4-15/16 2-1/2 -- -- 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

HD48 HU48 14 3-9/16 6-7/8 2-1/2 1-1/8 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HD48IF HUC48 14 3-9/16 6-7/8 2-1/2 -- -- 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

JUS48 LUS48, LUS48Z 18 3-5/8 6-7/8 2 1 6 16d 4 16d 3240 2550 14.41 11.34 2300 1811 10.23 8.06<br />

JUS410 LUS410, LUS410Z 18 3-5/8 8-7/8 2 1 8 16d 6 16d 5170 3735 23.00 16.61 3671 2652 16.33 11.80<br />

SUH410 U410 16 3-9/16 8-3/8 2 1-1/8 14 10d 6 10d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

HUS48 HUS48 14 3-5/8 7 2 1 6 16d 6 16d 3795 3405 16.88 15.15 2694 2418 11.98 10.76<br />

HUS48IF HUSC48 14 3-5/8 7 2 1 6 16d 6 16d 3795 3405 16.88 15.15 2694 2418 11.98 10.76<br />

HD48 HU48 14 3-9/16 6-7/8 2-1/2 1-1/8 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HD48IF HUC48 14 3-9/16 6-7/8 2-1/2 -- -- 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HUS410 HUS410 14 3-5/8 8-7/8 2 1 8 16d 8 16d 5185 4165 23.06 18.53 3681 2957 16.37 13.15<br />

HUS410IF HUSC410 14 3-5/8 8-7/8 2 -- -- 8 16d 8 16d 5185 4165 23.06 18.53 3681 2957 16.37 13.15<br />

HD410 HU410 14 3-9/16 8-13/16 2-1/2 1-1/8 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD410IF HUC410 14 3-9/16 8-13/16 2-1/2 -- -- 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ410IF HUCQ410-SDS 14 3-9/16 9 3 1-1/2 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

JUS410 LUS410, LUS410Z 18 3-5/8 8-7/8 2 1 8 16d 6 16d 5170 3735 23.00 16.61 3671 2652 16.33 11.80<br />

SUH410 U410 16 3-9/16 8-3/8 2 1-1/8 14 10d 6 10d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

HD48 HU48 14 3-9/16 6-7/8 2-1/2 1-1/8 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HD48IF HUC48 14 3-9/16 6-7/8 2-1/2 -- -- 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HUS410 HUS410 14 3-5/8 8-7/8 2 1 8 16d 8 16d 5185 4165 23.06 18.53 3681 2957 16.37 13.15<br />

HUS410IF HUSC410 14 3-5/8 8-7/8 2 -- -- 8 16d 8 16d 5185 4165 23.06 18.53 3681 2957 16.37 13.15<br />

HD410 HU410 14 3-9/16 8-13/16 2-1/2 1-1/8 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD410IF HUC410 14 3-9/16 8-13/16 2-1/2 -- -- 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ410IF HUCQ410-SDS 14 3-9/16 9 3 1-1/2 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

HUS412 HUS412 14 3-5/8 10-7/8 2 1 10 16d 10 16d 6345 5765 28.23 25.65 4505 4093 20.04 18.21<br />

HUS412IF HUSC412 14 3-5/8 10-7/8 2 -- -- 10 16d 10 16d 6345 5765 28.23 25.65 4505 4093 20.04 18.21<br />

HD412 HU412 14 3-9/16 10-13/16 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD412IF HUC412 14 3-9/16 10-13/16 2-1/2 -- -- 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ412IF HUCQ412-SDS 14 3-9/16 11 3 1-1/2 14 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

JUS414 LUS414 18 3-5/8 12-7/8 2 1 12 16d 6 16d 5120 3735 22.78 16.61 3635 2650 16.17 11.79<br />

SUH414 U414 16 3-9/16 10-1/16 2 1-1/8 16 10d 6 10d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

HD410 HU410 14 3-9/16 8-13/16 2-1/2 1-1/8 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD410IF HUC410 14 3-9/16 8-13/16 2-1/2 -- -- 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ410IF HUCQ410-SDS 14 3-9/16 9 3 1-1/2 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

HUS412 HUS412 14 3-5/8 10-7/8 2 1 10 16d 10 16d 6345 5765 28.23 25.65 4505 4093 20.04 18.21<br />

HUS412IF HUSC412 14 3-5/8 10-7/8 2 -- -- 10 16d 10 16d 6345 5765 28.23 25.65 4505 4093 20.04 18.21<br />

HD412 HU412 14 3-9/16 10-13/16 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD412IF HUC412 14 3-9/16 10-13/16 2-1/2 -- -- 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ412IF HUCQ412-SDS 14 3-9/16 11 3 1-1/2 14 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

HD414 HU414 14 3-9/16 12-13/16 2-1/2 1-1/8 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD414IF HUC414 14 3-9/16 12-13/16 2-1/2 -- -- 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

JUS414 LUS414 18 3-5/8 12-7/8 2 1 12 16d 6 16d 5120 3735 22.78 16.61 3635 2650 16.17 11.79<br />

SUH414 U414 16 3-9/16 10-1/16 2 1-1/8 16 10d 6 10d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

HD412 HU412 14 3-9/16 10-13/16 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD412IF HUC412 14 3-9/16 10-13/16 2-1/2 -- -- 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ412IF HUCQ412-SDS 14 3-9/16 11 3 1-1/2 14 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

HD414 HU414 14 3-9/16 12-13/16 2-1/2 1-1/8 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD414IF HUC414 14 3-9/16 12-13/16 2-1/2 -- -- 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD416 HU416 14 3-9/16 14-13/16 2-1/2 1-1/8 26 16d 12 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD416IF HUC416 14 3-9/16 14-13/16 2-1/2 -- -- 26 16d 12 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD414 HU414 14 3-9/16 12-13/16 2-1/2 1-1/8 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD414IF HUC414 14 3-9/16 12-13/16 2-1/2 -- -- 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD416 HU416 14 3-9/16 14-13/16 2-1/2 1-1/8 26 16d 12 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD416IF HUC416 14 3-9/16 14-13/16 2-1/2 -- -- 26 16d 12 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD418 -- -- 14 3-9/16 16-1/2 2-1/2 1-1/4 28 16d 8 10d 7215 2685 32.10 11.94 5123 1906 22.79 8.48<br />

SUH66 U66 16 5-1/2 5 2 1 8 10d 4 10d 3135 1665 13.95 7.41 2225 1180 9.90 5.25<br />

HD66 HU66 14 5-1/2 3-15/16 2-1/2 1-1/8 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

HD66IF HUC66 14 5-1/2 3-15/16 2-1/2 -- -- 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

SUH66 U66 16 5-1/2 5 2 1 8 10d 4 10d 3135 1665 13.95 7.41 2225 1180 9.90 5.25<br />

HD66 HU66 14 5-1/2 3-15/16 2-1/2 1-1/8 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

HD66IF HUC66 14 5-1/2 3-15/16 2-1/2 -- -- 12 16d 6 10d 3430 2685 15.26 11.94 2435 1906 10.83 8.48<br />

HD68 HU68 14 5-1/2 5-15/16 2-1/2 1-1/8 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HD68IF HUC68 14 5-1/2 5-15/16 2-1/2 -- -- 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) 16d sinkers may be used at 0.84 of the table load where 16d commons are specified.<br />

<br />

5) NAILS:<br />

red font.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

continued on next page<br />

<strong>USP</strong>2240-131<br />

95<br />

<strong>Hangers</strong>


Face Mount Hanger Charts continued<br />

<strong>Hangers</strong><br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Joist Size Stock No. Ref. No. Gauge W H D A Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

6 x 10<br />

6 x 12<br />

6 x 14<br />

6 x 16<br />

6 x 18<br />

8 x 6<br />

8 x 8<br />

8 x 10<br />

8 x 12<br />

8 x 14<br />

8 x 16<br />

Dimensions (in) Fastener Schedule 2,3,4,5<br />

Factored Resistance<br />

Header Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

SUH610 U610 16 5-1/2 9 2 1 14 10d 6 10d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

HD68 HU68 14 5-1/2 5-15/16 2-1/2 1-1/8 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HD68IF HUC68 14 5-1/2 5-15/16 2-1/2 -- -- 14 16d 6 10d 4675 2685 20.80 11.94 3319 1906 14.76 8.48<br />

HD610 HU610 14 5-1/2 7-13/16 2-1/2 1-1/8 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD610IF HUC610 14 5-1/2 7-13/16 2-1/2 -- -- 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ610IF HUCQ610-SDS 14 5-1/2 9 3 1-1/2 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

SUH610 U610 16 5-1/2 9 2 1 14 10d 6 10d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

HD610 HU610 14 5-1/2 7-13/16 2-1/2 1-1/8 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD610IF HUC610 14 5-1/2 7-13/16 2-1/2 -- -- 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ610IF HUCQ610-SDS 14 5-1/2 9 3 1-1/2 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

HD612 HU612 14 5-1/2 9-13/16 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD612IF HUC612 14 5-1/2 9-13/16 2-1/2 -- -- 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ612IF HUCQ612-SDS 14 5-1/2 11 3 1-1/2 14 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

HD610 HU610 14 5-1/2 7-13/16 2-1/2 1-1/8 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD610IF HUC610 14 5-1/2 7-13/16 2-1/2 -- -- 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ610IF HUCQ610-SDS 14 5-1/2 9 3 1-1/2 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

HD612 HU612 14 5-1/2 9-13/16 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD612IF HUC612 14 5-1/2 9-13/16 2-1/2 -- -- 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ612IF HUCQ612-SDS 14 5-1/2 11 3 1-1/2 14 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

HD614 HU614 14 5-1/2 11-13/16 2-1/2 1-1/8 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD614IF HUC614 14 5-1/2 11-13/16 2-1/2 -- -- 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD612 HU612 14 5-1/2 9-13/16 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD612IF HUC612 14 5-1/2 9-13/16 2-1/2 -- -- 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ612IF HUCQ612-SDS 14 5-1/2 11 3 1-1/2 14 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

HD614 HU614 14 5-1/2 11-13/16 2-1/2 1-1/8 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD614IF HUC614 14 5-1/2 11-13/16 2-1/2 -- -- 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD616 HU616 14 5-1/2 13-13/16 2-1/2 1-1/8 26 16d 12 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD616IF HUC616 14 5-1/2 13-13/16 2-1/2 -- -- 26 16d 12 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD614 HU614 14 5-1/2 11-13/16 2-1/2 1-1/8 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD614IF HUC614 14 5-1/2 11-13/16 2-1/2 1-1/8 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD616 HU616 14 5-1/2 13-13/16 2-1/2 1-1/8 26 16d 12 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD616IF HUC616 14 5-1/2 13-13/16 2-1/2 -- -- 26 16d 12 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HD86 -- -- 14 7-1/2 5-1/8 2-1/2 1-1/2 10 16d 4 16d 2525 4435 11.23 19.73 1793 3149 7.98 14.01<br />

HD86IF -- -- 14 7-1/2 5-1/8 2-1/2 1-1/2 10 16d 4 16d 2525 4435 11.23 19.73 1793 3149 7.98 14.01<br />

HD88 HU88 14 7-1/2 6-5/8 2-1/2 1-1/2 14 16d 6 16d 4900 4435 21.80 19.73 3479 3149 15.48 14.01<br />

HD88IF HUC88 14 7-1/2 6-5/8 2-1/2 1-1/2 14 16d 6 16d 4900 4435 21.80 19.73 3479 3149 15.48 14.01<br />

HD810 HU810 14 7-1/2 8-3/8 2-1/2 1-1/2 18 16d 8 16d 7315 4435 32.54 19.73 5194 3149 23.10 14.01<br />

HD810IF HUC810 14 7-1/2 8-3/8 2-1/2 -- -- 18 16d 8 16d 7315 4435 32.54 19.73 5194 3149 23.10 14.01<br />

HD812 HU812 14 7-1/2 10-1/8 2-1/2 1-1/2 22 16d 8 16d 7315 4435 32.54 19.73 5194 3149 23.10 14.01<br />

HD812IF HUC812 14 7-1/2 10-1/8 2-1/2 -- -- 22 16d 8 16d 7315 4435 32.54 19.73 5194 3149 23.10 14.01<br />

HD814 HU814 14 7-1/2 11-7/8 2-1/2 1-1/2 24 16d 12 16d 7315 5260 32.54 23.40 5194 3735 23.10 16.61<br />

HD814IF HUC814 7-1/2 11-7/8 2-1/2 -- -- 24 16d 12 16d 7315 5260 32.54 23.40 5194 3735 23.10 16.61<br />

HD816 HU816 14 7-1/2 13-5/8 2-1/2 1-1/2 26 16d 12 16d 7315 5260 32.54 23.40 5194 3735 23.10 16.61<br />

HD816IF HUC816 14 7-1/2 13-5/8 2-1/2 -- -- 26 16d 12 16d 7315 5260 32.54 23.40 5194 3735 23.10 16.61<br />

Rough Lumber Sizes<br />

2 x 4 SUH24R LU24R-18, U24R 16 2 3-1/16 2 1-1/8 4 10d 2 10d x 1 1/2 1390 795 6.18 3.54 985 565 4.38 2.51<br />

2 x 6 - 8 SUH26R LU26R-18, U26R 16 2 4-15/16 2 1-3/16 6 10d 4 10d x 1 1/2 2345 1505 10.43 6.69 1665 1070 7.41 4.76<br />

2 x 8 - 10 SUH28R LU28R-18 16 2 6-7/16 2 1-1/8 8 10d 6 10d x 1-1/2 2345 1505 10.43 6.69 1665 1070 7.41 4.76<br />

2 x 10 - 14 SUH210R LU210R-18, U210R 16 2 7-13/16 2 1-1/8 10 10d 6 10d x 1 1/2 4080 2505 18.15 11.14 2895 1780 12.88 7.92<br />

2 x 14 - 16 SUH214R -- -- 16 2 9-13/16 2 1-1/8 12 10d 6 10d x 1-1/2 4105 2505 18.26 11.14 2915 1780 12.97 7.92<br />

4 x 6 SUH44R U44R 16 4 2-11/16 2 1-1/8 6 10d 2 16d 1910 825 8.50 3.67 1355 585 6.03 2.60<br />

4 x 8 SUH46R U46R 16 4 4-11/16 2 1-1/8 8 10d 4 16d 3135 1665 13.95 7.41 2225 1180 9.90 5.25<br />

4 x 10 SUH410R U410R 16 4 8-3/16 2 2 14 10d 6 16d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

6 x 8 SUH66R U66R 16 6 5 2 1 8 10d 4 16d 3135 1665 13.95 7.41 2225 1180 9.90 5.25<br />

6 x 10 SUH610R U610R 16 6 9 2 1 14 10d 6 16d 5730 2920 25.49 12.99 4070 2075 18.10 9.23<br />

Glulam Sizes<br />

3-1/8 x<br />

10-1/2 - 19-1/2<br />

HD32105 HU3.25/10.5 14 3-1/4 9-15/16 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

3-1/8 x<br />

12 - 21<br />

HD3212 HU3.25/12 14 3-1/4 11-7/8 2-1/2 1-1/8 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

5-1/8 x<br />

10-1/2 - 19-1/2<br />

HD5112 HU5.125/12 14 5-1/4 9-15/16 2-1/2 1-1/8 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

5-1/8 x<br />

14-1/2 - 21<br />

HD51135 HU5.125/13.5 14 5-1/4 12-15/16 2-1/2 1-1/8 26 16d 12 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) 16d sinkers may be used at 0.84 of the table load where 16d commons are specified.<br />

<br />

5) NAILS:<br />

red font.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

96<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Beam & Purlin <strong>Hangers</strong> – KB & KLB series<br />

With a top mount design and heavy steel fabrication the KB<br />

and KLB hangers can cover medium-to-heavy beam and purlin<br />

applications. The top mount design offers high loads with less<br />

nailing than comparable face mount hangers.<br />

TF<br />

KLB – 14 gauge.<br />

KB – 12 gauge.<br />

H<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• NA20D and NA25 nails are included with hangers where<br />

applicable.<br />

• KB models are not recommended for use with LVL, PSL,<br />

or LSL members.<br />

Heavy Duty Top-Mount <strong>Hangers</strong> – HDO series<br />

W<br />

W<br />

KB<br />

KLB<br />

D<br />

TF<br />

H<br />

D<br />

Primarily used to hang joists or headers in medium load<br />

conditions. These hangers provide higher load values with<br />

less nailing.<br />

1 1 /4˝<br />

Materials: 12 gauge<br />

Finish: G90 galvanizing<br />

Options: All nominal lumber sizes are available for<br />

rough/fullsize lumber. See Specialty Options<br />

Chart.<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Check top flange dimensions to ensure compatibility with<br />

header widths.<br />

• Do not use for welded or nailer applications.<br />

Reference Specialty Options chart below for hanger<br />

options.<br />

W<br />

HDO28-2<br />

H<br />

D<br />

TF<br />

Specialty Options Chart – refer to Specialty Options pages 210 to 211 for<br />

additional details.<br />

Option Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Inverted Flange<br />

Range<br />

Factored<br />

Resistance<br />

Ordering<br />

<br />

<br />

<br />

100% of table load.<br />

75% of uplift load<br />

on skews greater<br />

<br />

Add SK, angle required,<br />

and right (R) or left (L),<br />

to product number.<br />

Ex. HDO210-SK45R<br />

<br />

100% of table load<br />

Add SL, slope required,<br />

and up (U) or down (D),<br />

to product number.<br />

Ex. HDO210-SL30D<br />

See Sloped Seat and Skewed<br />

80% of table load.<br />

75% of uplift load<br />

on skews greater<br />

<br />

See Sloped Seat and Skewed.<br />

Ex. HDO210-SK45RSL30D<br />

Not available in<br />

<br />

100% of table load.<br />

65% of table load when<br />

nailing into the support<br />

members end grain.<br />

Add IF<br />

to product number.<br />

Ex. HDO610IF<br />

1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange.<br />

2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails.<br />

3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-joists.<br />

Typical HDO410IF<br />

inverted flange installation<br />

Typical HDO skewed<br />

option installation<br />

<strong>Hangers</strong><br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 97<br />

<strong>USP</strong>2240-131


Welded Top Flange <strong>Hangers</strong> – KHW, SW, & SWH series<br />

SW – Light-duty hanger.<br />

SWH – Medium-duty hanger.<br />

KHW – Heavy-duty hanger installs with NA20D nails for higher load<br />

capacities.<br />

Materials: SW top flange - 12 gauge; stirrup - 12 gauge;<br />

SWH top flange - 7 gauge; stirrup - 12 gauge;<br />

KHW top flange - 3 gauge; stirrup - 10 gauge.<br />

Finish: <strong>USP</strong> primer<br />

Options: All nominal lumber sizes are available for<br />

rough/full size lumber. See Specialty<br />

Options Chart.<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product<br />

Notes, page 10.<br />

• NA20D nails are supplied with KHW hangers<br />

• For welded installations see page 213.<br />

• KHW models are not recommended for<br />

use with LVL, PSL, or LSL members.<br />

Nailer Installation Chart – chart represents<br />

maximum factored resistance for hangers used<br />

on wood nailers. Reference page 117.<br />

<strong>USP</strong><br />

Stock No.<br />

Nailer<br />

Size<br />

Fastener Schedule 1,3<br />

Header<br />

Joist<br />

Factored Resistance (100%) 2<br />

DF-L<br />

S-P-F<br />

Qty Type Qty Type Lbs kN Lbs kN<br />

SW 2X 2 10d x 1-1/2 2 10d x 1-1/2 2355 10.48 1605 7.14<br />

2X 2 10d x 1-1/2 2 10d 3745 16.66 2550 11.34<br />

SWH<br />

3X 2 16d x 2-1/2 2 10d 4825 21.46 3285 14.61<br />

KHW 3X 4 16d x 2-1/2 2 10d 7460 33.19 5075 22.58<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) Listed loads shall not be increased.<br />

3) NAILS:<br />

<br />

red font.<br />

W<br />

L<br />

SWH410<br />

D<br />

H<br />

2 1 /2˝<br />

Typical KHW46<br />

installation<br />

L<br />

KHW46<br />

Option Skewed 1 Sloped Seat 2 Sloped / Skewed 1,2 Sloped Top Flange 3 Top Flange Offset<br />

Saddle Ridge<br />

Range<br />

Factored<br />

Resistance<br />

Ordering<br />

<br />

100% of table value<br />

Add SK, angle required,<br />

and right (R) or left (L),<br />

to product number.<br />

<br />

<br />

Add SL, slope required,<br />

and up (U) or down (D),<br />

to product number.<br />

Ex. SW212-SL30D<br />

See Sloped Seat<br />

and Skewed<br />

100% of table value 100% of table value<br />

See Sloped Seat<br />

and Skewed.<br />

<br />

1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange.<br />

2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails.<br />

3) Sloped top flanges with greater than 15° may have additional header nails.<br />

0° to 35° -- --<br />

-- -- <br />

<br />

values using<br />

straight-line interpolation<br />

Add SF, angle required,<br />

and right (R) or left (L),<br />

to product number.<br />

Ex. SW212-SF30L<br />

Typical SW210<br />

installation<br />

Specialty Options Chart – refer to Specialty Options pages 210 and 212 for additional details.<br />

2 1 /2˝<br />

W<br />

Hanger Width<br />

<br />

<br />

<br />

Add OS, and<br />

right (R) or left (L),<br />

to product number.<br />

Ex. SW212-OSL<br />

L<br />

SW210<br />

D<br />

% of table value:<br />

60%<br />

75%<br />

<br />

H<br />

100% of table value<br />

per side<br />

Add SA, and saddle<br />

width required<br />

to product number.<br />

<br />

D<br />

H<br />

100% of table value<br />

Add DA,<br />

angle required<br />

to product number.<br />

Ex. SW212-DA30<br />

2 1 /2˝<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Light Gauge Purlin <strong>Hangers</strong> – HL series<br />

TF<br />

<strong>Hangers</strong><br />

These top mount hangers are designed for supporting floor joists or 2x purlins.<br />

The top mount style allows builders to drop in joists or purlins quickly.<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

W<br />

HL210<br />

D<br />

H<br />

98<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Top Mount Hanger Charts<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Beam/<br />

Joist Size<br />

Steel<br />

Floor Uplift 1,2 Floor Uplift 1,2 Floor Uplift 1,2 Floor Uplift 1,2<br />

Ref. No. Gauge W H D L TF Top Face Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

2 x 4 HDO24 HU24TF 12 1-9/16 3-7/16 2-1/4 -- -- 2-1/2 4 2 16d 2 10d x 1-1/2 3125 325 13.90 1.45 2625 275 11.68 1.22<br />

2 x 6<br />

2 x 8<br />

2 x 10<br />

2 x 12<br />

2 x 14<br />

2 x 16<br />

HL26 JB26 18 1-9/16 5-3/8 1-1/2 -- -- 1-5/16 2 4 16d 2 prongs 1830 -- -- 8.14 -- -- 1245 -- -- 5.54 -- --<br />

KLB26 LB26 14 1-9/16 5-3/8 1-1/2 -- -- 1-3/8 2 4 16d 2 10d x 1-1/2 3325 670 14.79 2.98 2905 585 12.92 2.60<br />

SW26 W26 12 1-9/16 5-3/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 3335 -- -- 14.84 -- -- 2265 -- -- 10.08 -- --<br />

HDO26 HU26TF 12 1-9/16 5-3/8 2-1/4 -- -- 2-1/2 4 6 16d 4 10d x 1-1/2 3730 795 16.59 3.54 3135 670 13.95 2.98<br />

HL28 JB28 18 1-9/16 7-5/16 1-3/4 -- -- 1-5/16 2 4 16d 2 prongs 2290 -- -- 10.19 -- -- 1555 -- -- 6.92 -- --<br />

KLB28 LB28 14 1-9/16 7-1/4 1-3/4 -- -- 1-3/8 2 4 16d 2 10d x 1-1/2 3325 670 14.79 2.98 2905 585 12.92 2.60<br />

SW28 W28 12 1-9/16 7-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 3335 -- -- 14.84 -- -- 2265 -- -- 10.08 -- --<br />

HDO28 HU28TF 12 1-9/16 7-1/8 2-1/4 -- -- 2-1/2 4 6 16d 4 10d x 1-1/2 3730 780 16.59 3.47 3135 655 13.95 2.91<br />

HL210 JB210 18 1-9/16 9-5/16 2 -- -- 1-5/16 2 4 16d 2 prongs 2290 -- -- 10.19 -- -- 1555 -- -- 6.92 -- --<br />

KLB210 LB210 14 1-9/16 9-1/4 2 -- -- 1-3/8 2 4 16d 2 10d x 1-1/2 3325 670 14.79 2.98 2905 585 12.92 2.60<br />

SW210 W210 12 1-9/16 9-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 3335 -- -- 14.84 -- -- 2265 -- -- 10.08 -- --<br />

HDO210 HU210TF 12 1-9/16 9-1/8 2-1/4 -- -- 2-1/2 4 8 16d 4 10d x 1-1/2 3730 750 16.59 3.34 3135 630 13.95 2.80<br />

HL212 JB212 18 1-9/16 11-1/4 2-1/8 -- -- 1-5/16 2 4 16d 2 prongs 2290 -- -- 10.19 -- -- 1555 -- -- 6.92 -- --<br />

KLB212 LB212 14 1-9/16 11-1/8 2 -- -- 1-3/8 2 4 16d 2 10d x 1-1/2 3325 670 14.79 2.98 2905 585 12.92 2.60<br />

SW212 W212 12 1-9/16 11-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 3335 -- -- 14.84 -- -- 2265 -- -- 10.08 -- --<br />

HDO212 HU212TF 12 1-9/16 11 2-1/4 -- -- 2-1/2 4 10 16d 6 10d x 1-1/2 3390 1190 15.08 5.29 2850 1000 12.68 4.45<br />

HL214 JB214, LB214 18 1-9/16 13-1/8 2 -- -- 2-1/2 2 6 16d 2 10d x 1-1/2 2290 375 10.19 1.67 1925 315 8.56 1.40<br />

SW214 W214 12 1-9/16 13-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 3335 -- -- 14.84 -- -- 2265 -- -- 10.08 -- --<br />

HDO214 HU214TF 12 1-9/16 13 2-1/4 -- -- 2-1/2 4 12 16d 6 10d x 1-1/2 4075 1085 18.13 4.83 3425 910 15.24 4.05<br />

SW216 W216 12 1-9/16 15-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 3335 -- -- 14.84 -- -- 2265 -- -- 10.08 -- --<br />

HDO216 HU216TF, LB216 12 1-9/16 15 2-1/4 -- -- 2-1/2 4 14 16d 8 10d x 1-1/2 4420 1590 19.66 7.07 3715 1335 16.53 5.94<br />

3 x 4 HDO34 HU34TF 12 2-9/16 3-7/16 2-1/2 -- -- 2-1/2 4 4 16d 2 10d x 1-1/2 3840 325 17.08 1.45 3225 275 14.35 1.22<br />

3 x 6<br />

3 x 8<br />

3 x 10<br />

3 x 12<br />

3 x 14<br />

3 x 16<br />

SW36 W36 12 2-9/16 5-3/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 3335 -- -- 14.84 -- -- 2265 -- -- 10.08 -- --<br />

HDO36 HU36TF 12 2-9/16 5-3/8 2-1/2 -- -- 2-1/2 4 6 16d 4 10d x 1-1/2 4335 795 19.28 3.54 3640 670 16.19 2.98<br />

SW38 W38 12 2-9/16 7-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 3335 -- -- 14.84 -- -- 2265 -- -- 10.08 -- --<br />

HDO38 B38, HU38TF 12 2-9/16 7-1/8 2-1/2 -- -- 2-1/2 4 8 16d 4 10d x 1-1/2 5190 780 23.09 3.47 4360 655 19.40 2.91<br />

SW310 W310 12 2-9/16 9-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d x 1-1/2 3335 -- -- 14.84 -- -- 2265 -- -- 10.08 -- --<br />

HDO310 B310, HU310TF 12 2-9/16 9-1/8 2-1/2 -- -- 2-1/2 4 10 16d 6 10d x 1-1/2 6000 1190 26.69 5.29 5040 1000 22.42 4.45<br />

SWH312 WNP312 7/12 2-9/16 11-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d x 1-1/2 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

HDO312 B312, HU312TF 12 2-9/16 11 2-1/2 -- -- 2-1/2 4 12 16d 6 10d x 1-1/2 6445 1190 28.67 5.29 5415 1000 24.09 4.45<br />

SWH314 WNP314 7/12 2-9/16 13-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d x 1-1/2 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

HDO314 B314, HU314TF 12 2-9/16 13 2-1/2 -- -- 2-1/2 4 14 16d 8 10d x 1-1/2 6445 1360 28.67 6.05 5415 1140 24.09 5.07<br />

SWH316 WNP316 7/12 2-9/16 15-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d x 1-1/2 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

HDO316 B316, HU316TF 12 2-9/16 15 2-1/2 -- -- 2-1/2 4 16 16d 8 10d x 1-1/2 7005 1590 31.16 7.07 5885 1335 26.18 5.94<br />

(2) 2 x 4 HDO24-2 HU24-2TF 12 3-1/8 3-7/16 2-1/4 -- -- 2-1/2 4 4 16d 2 10d 3520 420 15.66 1.87 2955 355 13.15 1.58<br />

(2) 2 x 6<br />

(2) 2 x 8<br />

(2) 2 x 10<br />

<strong>USP</strong><br />

Stock No.<br />

Dimensions (in)<br />

SWH26-2 WNP26-2 7/12 3-1/8 5-3/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

HDO26-2<br />

HU26-2TF,<br />

HUS26-2TF<br />

12 3-1/8 5-3/8 2-1/4 -- -- 2-1/2 4 6 16d 4 10d 4390 845 19.53 3.76 3690 710 16.41 3.16<br />

SWH28-2 WNP28-2 7/12 3-1/8 7-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

HDO28-2<br />

HU28-2TF,<br />

HUS28-2TF<br />

12 3-1/8 7-1/8 2-1/4 -- -- 2-1/2 4 8 16d 4 10d 5510 845 24.51 3.76 4630 710 20.60 3.16<br />

SWH210-2 WNP210-2 7/12 3-1/8 9-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

HDO210-2<br />

HU210-2TF,<br />

HUS210-2TF<br />

12 3-1/8 9-1/8 2-1/2 -- -- 2-1/2 4 10 16d 6 10d 6575 1265 29.25 5.63 5525 1065 24.58 4.74<br />

HDO210-2IF<br />

HUC210-2TF,<br />

HUSC210-2TF<br />

12 3-1/8 9-1/8 2-1/2 -- -- 2-1/2 4 10 16d 6 10d 6575 1265 29.25 5.63 5525 1065 24.58 4.74<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) HL, SW, and SWH products do not provide uplift resistance, except for the HL214.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) NAILS:<br />

New products or updated product information are designated in red font.<br />

Qty<br />

Fastener Schedule 3,4<br />

Header<br />

Joist<br />

DF-L<br />

Factored Resistance (Lbs.)<br />

S-P-F<br />

Lbs kN Lbs kN<br />

2 1 /2˝<br />

L<br />

H<br />

<strong>Hangers</strong><br />

W<br />

D<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 99<br />

<strong>USP</strong>2240-131


Top Mount Hanger Charts continued<br />

Beam/<br />

Joist Size<br />

Dimensions (in)<br />

Fastener Schedule 3,5<br />

<strong>USP</strong><br />

Steel<br />

Floor Uplift 1,2 Floor Uplift 1,2 Floor Uplift 1,2 Floor Uplift 1,2<br />

Stock No. Ref. No. Gauge W H D L TF Top Face Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

SWH212-2 WNP212-2 7/12 3-1/8 11-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

(2) 2 x 12<br />

HU212-2TF,<br />

HDO212-2<br />

HUS212-2TF<br />

12 3-1/8 11 2-1/2 -- -- 2-1/2 4 12 16d 6 10d 7025 1265 31.25 5.63 5900 1065 26.25 4.74<br />

SWH214-2 WNP214-2 7/12 3-1/8 13-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

(2) 2 x 14<br />

HU214-2TF,<br />

HDO214-2<br />

HUS214-2TF<br />

12 3-1/8 13 2-1/2 -- -- 2-1/2 4 14 16d 8 10d 7450 1680 33.14 7.47 6260 1410 27.85 6.27<br />

(2) 2 x 16<br />

SWH216-2 WNP216-2 7/12 3-1/8 15-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

HDO216-2 HU216-2TF 12 3-1/8 15 2-1/2 -- -- 2-1/2 4 16 16d 8 10d 7885 1680 35.08 7.47 6625 1410 29.47 6.27<br />

4 x 4 HDO44 HU44TF 12 3-9/16 3-7/16 2-1/4 -- -- 2-1/2 4 4 16d 2 10d 3520 420 15.66 1.87 2955 355 13.15 1.58<br />

SW46 W46 12 3-9/16 5-3/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d 3630 -- -- 16.15 -- -- 2470 -- -- 10.99 -- --<br />

4 x 6 HDO46<br />

HU46TF,<br />

HUS46TF<br />

12 3-9/16 5-3/8 2-1/4 -- -- 2-1/2 4 6 16d 4 10d 4390 845 19.53 3.76 3690 710 16.41 3.16<br />

KHW46 HW46 3/10 3-9/16 5-3/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

SW48 W48 12 3-9/16 7-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d 3630 -- -- 16.15 -- -- 2470 -- -- 10.99 -- --<br />

4 x 8 HDO48<br />

B48, BA48,<br />

HU48TF,<br />

12 3-9/16 7-1/8 2-1/4 -- -- 2-1/2 4 8 16d 4 10d 5510 845 24.51 3.76 4630 710 20.60 3.16<br />

HUS48TF<br />

KHW48 HW48 3/10 3-9/16 7-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

SW410 W410 12 3-9/16 9-1/8 2-1/2 6-1/2 2-1/2 2 -- -- 10d 2 10d 3630 -- -- 16.15 -- -- 2470 -- -- 10.99 -- --<br />

B410, HU410TF,<br />

4 x 10<br />

HDO410 HUI49.5TF, 12 3-9/16 9-1/8 2-1/4 -- -- 2-1/2 4 10 16d 6 10d 6575 1265 29.25 5.63 5525 1065 24.58 4.74<br />

HUS410TF<br />

SWH410 -- -- 7/12 3-9/16 9-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

KHW410 HW410 3/10 3-9/16 9-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

KB412 B412 12 3-9/16 11-1/8 2-3/8 -- -- 2-1/2 2 4 NA20D 2 NA20D 4165 810 18.53 3.60 2960 750 13.17 3.34<br />

HU412TF,<br />

HDO412<br />

4 x 12<br />

HUS412TF<br />

12 3-9/16 11 2-1/4 -- -- 2-1/2 4 12 16d 6 10d 7025 1265 31.25 5.63 5900 1065 26.25 4.74<br />

SWH412 WNP412 7/12 3-9/16 11-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

KHW412 HW412 3/10 3-9/16 11-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

HDO414<br />

B414, HHB414,<br />

HU414TF,<br />

HUI414TF,<br />

12 3-9/16 13 2-1/2 -- -- 2-1/2 4 14 16d 8 10d 7450 1680 33.14 7.47 6260 1410 27.85 6.27<br />

4 x 14<br />

HUS414TF<br />

SWH414 WNP414 7/12 3-9/16 13-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

KHW414 HW414 3/10 3-9/16 13-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

HDO416<br />

B416, HHB416,<br />

HU416TF<br />

12 3-9/16 15 2-1/2 -- -- 2-1/2 4 16 16d 8 10d 7885 1680 35.08 7.47 6625 1410 29.47 6.27<br />

4 x 16<br />

SWH416 WNP416 7/12 3-9/16 15-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

KHW416 HW416 3/10 3-9/16 15-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

(3) 2 x 10 HDO210-3 HU210-3TF 12 4-11/16 9-1/8 2-1/2 -- -- 2-1/2 4 10 16d 6 16d 6575 1480 29.25 6.58 5525 1245 24.58 5.54<br />

(3) 2 x 12 HDO212-3 HU212-3TF 12 4-11/16 11 2-1/2 -- -- 2-1/2 4 12 16d 6 16d 7025 1480 31.25 6.58 5900 1245 26.25 5.54<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) KHW, SW, and SWH products do not provide uplift resistance.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) KHW Glulam load values are based on 560 psi perpendicular to grain loading.<br />

5) NAILS:<br />

New products or updated product information are designated in red font.<br />

Qty<br />

Header<br />

Joist<br />

Lbs<br />

DF-L<br />

Factored Resistance (Lbs.) 4<br />

kN<br />

2 1 /2˝<br />

Lbs<br />

S-P-F<br />

L<br />

kN<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

H<br />

<strong>Hangers</strong><br />

W<br />

D<br />

continued on next page<br />

100<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Top Mount Hanger Charts continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Factored Resistance (Lbs.) 4<br />

Dimensions (in) Fastener Schedule 3,5<br />

Glulam Sizes 5 Header<br />

Joist<br />

DF-L<br />

S-P-F<br />

Qty<br />

Lbs kN Lbs kN<br />

Beam/ <strong>USP</strong><br />

Steel<br />

Floor Uplift 1,2 Floor Uplift 1,2 Floor Uplift 1,2 Floor Uplift 1,2<br />

Joist Size Stock No. Ref. No. Gauge W H D L TF Top Face Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

(3) 2 x 14 HDO214-3 HU214-3TF 12 4-11/16 13 2-1/2 -- -- 2-1/2 4 14 16d 8 16d 7450 1770 33.14 7.87 6260 1485 27.85 6.61<br />

(3) 2 x 16 HDO216-3 HU216-3TF 12 4-11/16 15 2-1/2 -- -- 2-1/2 4 16 16d 8 16d 7885 1970 35.08 8.76 6625 1655 29.47 7.36<br />

HDO66 HU66TF 12 5-1/2 5-3/8 2-1/2 -- -- 2-1/2 4 6 16d 4 16d 4390 990 19.53 4.40 3690 830 16.41 3.69<br />

6 x 6 SWH66 WNP66 7/12 5-1/2 5-3/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

KHW66 HW66 3/10 5-1/2 5-3/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

HDO68 HHB68, HU68TF 12 5-1/2 7-1/8 2-1/2 -- -- 2-1/2 4 8 16d 4 16d 5510 990 24.51 4.40 4630 830 20.60 3.69<br />

6 x 8 SWH68 WNP68 7/12 5-1/2 7-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

KHW68 HW68 3/10 5-1/2 7-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

KB610 B610 12 5-1/2 9-1/4 2-3/8 -- -- 2-1/2 2 6 NA20D 2 NA20D 5075 810 22.58 3.60 3605 750 16.04 3.34<br />

HHB610,<br />

HDO610<br />

6 x 10<br />

HU610TF<br />

12 5-1/2 9-1/8 2-1/2 -- -- 2-1/2 4 10 16d 6 16d 6575 1480 29.25 6.58 5525 1245 24.58 5.54<br />

SWH610 WNP610 7/12 5-1/2 9-1/8 2-1/2 7 2-1/2 2 -- -- 10d 2 10d 4760 -- -- 21.17 -- -- 3235 -- -- 14.39 -- --<br />

KHW610 HW610 3/10 5-1/2 9-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

KB612 B612 12 5-1/2 11-1/8 2-3/8 -- -- 2-1/2 2 6 NA20D 2 NA20D 5075 810 22.58 3.60 3605 750 16.04 3.34<br />

6 x 12 HDO612<br />

HHB612,<br />

HU612TF<br />

12 5-1/2 11 2-1/2 -- -- 2-1/2 4 12 16d 6 16d 7025 1480 31.25 6.58 5900 1245 26.25 5.54<br />

KHW612 HW612 3/10 5-1/2 11-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

B614, HHB614,<br />

HDO614<br />

6 x 14<br />

HU614TF<br />

12 5-1/2 13 2-1/2 -- -- 2-1/2 4 14 16d 8 16d 7450 1770 33.14 7.87 6260 1485 27.85 6.61<br />

KHW614 HW614 3/10 5-1/2 13-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

B616, HHB616,<br />

HDO616<br />

6 x 16<br />

HU616TF<br />

12 5-1/2 15 2-1/2 -- -- 2-1/2 4 16 16d 8 16d 7885 1970 35.08 8.76 6625 1655 29.47 7.36<br />

KHW616 HW616 3/10 5-1/2 15-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

8 x 6 KHW86 HW86 3/10 7-1/2 5-3/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

8 x 8 KHW88 HW88 3/10 7-1/2 7-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

8 x 10 KHW810 HW810 3/10 7-1/2 9-1/8 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

8 x 12 KHW812 HHB812, HW812 3/10 7-1/2 11-1/8 2-1/2 10 2-1/2 4 NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

8 x 14 KHW814 HHB814, HW814 3/10 7-1/2 13-1/8 2-1/2 10 2-1/2 4 NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

8 x 16 KHW816 HHB816, HW816 3/10 7-1/2 15-1/8 2-1/2 10 2-1/2 4 NA20D 2 10d 7680 -- -- 34.16 -- -- 5225 -- -- 23.24 -- --<br />

2-1/2 glulam KHW26 -- -- 3/10 2-11/16 specify 4 10 2-1/2 4 -- -- NA20D 2 10d x 1-1/2 7625 -- -- 33.92 -- -- 5185 -- -- 23.06 -- --<br />

3-1/8 glulam KHW3 HW3.25 3/10 3-1/4 specify 3 10 2-1/2 4 -- -- NA20D 2 10d 7625 -- -- 33.92 -- -- 5185 -- -- 23.06 -- --<br />

5-1/8 glulam KHW5 HW5.25 3/10 5-1/4 specify 2-1/2 10 2-1/2 4 -- -- NA20D 2 10d 7625 -- -- 33.92 -- -- 5185 -- -- 23.06 -- --<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) KHW and SWH products do not provide uplift resistance.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) KHW Glulam load values are based on 560 psi perpendicular to grain loading.<br />

5) Consult <strong>USP</strong> for additional Glulam sizes.<br />

6) NAILS:<br />

New products or updated product information are designated in red font.<br />

2 1 /2˝<br />

L<br />

H<br />

W<br />

D<br />

<strong>Hangers</strong><br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 101<br />

<strong>USP</strong>2240-131


Multi-Purpose Joist Hanger – JH20<br />

These strap-style hangers are designed to support trusses, joists,<br />

or purlins. JH models may be bent along the flange allowing<br />

builders to use the hangers in top mount, face mount, or<br />

combination applications.<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

NEW<br />

Raised<br />

dimple allows<br />

30º to 45˚<br />

nailing<br />

B<br />

TF<br />

H<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Joist nails must be driven at a 30° to 45° angle through the joist<br />

or truss into the header to achieve listed loads. Standard length<br />

“double shear” nails must be used to achieve listed load<br />

values.<br />

• If installing in top mount configuration, field bend top flange over<br />

header.<br />

• 16d sinkers (9 gauge x 3 1 /4˝) may be used where 10d common<br />

are specified with no load reduction.<br />

W<br />

JH20<br />

D<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Double shear nail design<br />

features fewer nails and<br />

faster installation<br />

Uses standard<br />

length nails<br />

Dimensions (in)<br />

Fastener Schedule 2,3,4<br />

<strong>USP</strong><br />

Steel<br />

Header Top Face Floor Uplift 1 Floor Uplift 1<br />

Joist Size Stock No. Ref. No. Gauge W H D B TF Size Qty Qty Type Qty Type Unit 100% 115% 100% 115%<br />

Lbs 3565 1065 2745 955<br />

2 4 10d 6 10d<br />

kN 15.86 4.74 12.21 4.25<br />

Lbs 3565 1065 3060 955<br />

2 8 10d 6 10d<br />

kN 15.86 4.74 13.61 4.25<br />

JH20 -- -- 18 <br />

Lbs 4750 2415 3375 1715<br />

2 12 10d 6 10d<br />

kN 21.13 10.74 15.01 7.63<br />

Lbs 3770 2415 3375 1715<br />

-- -- -- -- 14 10d 6 10d<br />

kN 16.77 10.74 15.01 7.63<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

<br />

4) NAILS:<br />

red font.<br />

Header<br />

Joist<br />

Factored Resistance<br />

DF-L<br />

S-P-F<br />

<strong>Hangers</strong><br />

102<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Slope/Skew <strong>Hangers</strong> – LSSH series<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

The LSSH series connects rafters to ridge beams in vaulted<br />

roof structures. This series is field adjustable to meet a<br />

variety of skew and/or slope applications. Slopes to any pitch<br />

up to 45° up or down and skews up to 45° right or left.<br />

Materials: See chart<br />

Finish: G90 galvanizing; LSSH15-TZ – G-185<br />

Triple Zinc galvanizing<br />

Options: LSSH210 and LSSH31 are available in Triple<br />

Zinc. To order, add TZ to stock number, as in<br />

LSSH210-TZ. LSSH15 and LSSH210 are<br />

available in Stainless steel. To order, add SS<br />

to stock number, as in LSSH210-SS.<br />

Codes: Factored resistances are derived from data<br />

submitted to various North American building<br />

code evaluators and are in accordance with<br />

CSA O86-09.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

Steps:<br />

1. Position LSSH connector against plumb-cut end of rafter joist.<br />

Fasten joist side flanges with 10d (0.148") x 11/2˝ nails.<br />

Bend seat up to fit against joist bottom and drive<br />

(1) 10d (0.148") x 11/2˝ nail through bottom seat into rafter<br />

bottom. Drive (2) 10d (0.148") x 11/2˝ nails at downward<br />

angle through dimpled nailing guides.<br />

2. Lean connector and rafter end against ridge beam at desired<br />

position. Install 10d (0.148" x 3") or 16d (0.162" x 3 1/2˝) nails<br />

through nail holes into ridge beam at right 90° angle.<br />

If skewing the rafter, only drive nails into ridge beam on inside<br />

flange.<br />

3. Bend outside flange to desired angle.<br />

4. Hammer outside flange until edge touches header. Fasten<br />

outside flange to ridge by driving 10d (0.148" x 3") or<br />

16d (0.162" x 3 1/2˝) nails through nail holes.<br />

• Web stiffeners are required for all wood I-Joist installations.<br />

2<br />

skew to 45˚ 45° maximum<br />

Slope to<br />

45˚ up<br />

or down<br />

1<br />

3 & 4<br />

Typical LSSH179<br />

installation<br />

W 2<br />

Slope to<br />

45˚ up<br />

or down<br />

W 1<br />

LSSH35<br />

Dimensions (in)<br />

Fastener Schedule 2,3<br />

Factored Resistance<br />

Header Rafter DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Rafter <strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Width Stock No. Ref. No. Gauge W1 W2 H Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

SLOPED ONLY HANGERS<br />

1-1/2 LSSH15-TZ<br />

LSU26, LSU26Z,<br />

LSSU28, LSSU28Z<br />

18 1-9/16 1-3/4 5-1/16 6 10d HDG 7 10d x 1-1/2 HDG 1640 1395 7.30 6.21 1165 995 5.18 4.43<br />

1-1/2 LSSH210 LSSU210 18 1-9/16 1-3/4 8-13/16 10 10d 7 10d x 1-1/2 2775 2005 12.34 8.92 1970 1425 8.76 6.34<br />

1-3/4 LSSH179 LSSUI25 18 1-13/16 1-5/8 8-13/16 10 10d 7 10d x 1-1/2 2775 2005 12.34 8.92 1970 1425 8.76 6.34<br />

2 - 2-1/8 LSSH20<br />

LSSUI2.06,<br />

LSSU2.1<br />

18 2-1/8 2-1/2 8-13/16 10 10d 7 10d x 1-1/2 2620 1845 11.65 8.21 1860 1310 8.27 5.83<br />

2-1/4 - 2-5/16 LSSH23 LSSUI35 18 2-5/16 2-3/8 8-13/16 10 10d 7 10d x 1-1/2 2620 1845 11.65 8.21 1860 1310 8.27 5.83<br />

2-1/2 LSSH25 LSSUH310 16 2-9/16 2-3/4 8-13/16 18 16d 12 10d x 1-1/2 4260 2250 18.95 10.01 3025 1600 13.46 7.12<br />

2-5/8 LSSH26 -- -- 16 2-11/16 2-5/8 8-13/16 18 16d 12 10d x 1-1/2 4260 2250 18.95 10.01 3025 1600 13.46 7.12<br />

3 LSSH31 LSSU210-2 16 3-1/8 3-3/4 8-13/16 18 16d 12 10d x 1-1/2 5230 2985 23.27 13.28 3715 2120 16.53 9.43<br />

3-1/2 LSSH35 LSSU410 16 3-9/16 3-1/2 8-13/16 18 16d 12 10d x 1-1/2 5230 2985 23.27 13.28 3715 2120 16.53 9.43<br />

SKEWED HANGERS or SLOPED & SKEWED HANGERS<br />

1-1/2 LSSH15-TZ<br />

LSU26, LSU26Z,<br />

LSSU28, LSSU28Z<br />

18 1-9/16 1-3/4 5-1/16 6 10d HDG 7 10d x 1-1/2 HDG 1340 1395 5.96 6.21 950 995 4.23 4.43<br />

1-1/2 LSSH210 LSSU210 18 1-9/16 1-3/4 8-13/16 10 10d 7 10d x 1-1/2 2775 2005 12.34 8.92 1970 1425 8.76 6.34<br />

1-3/4 LSSH179 LSSUI25 18 1-13/16 1-5/8 8-13/16 10 10d 7 10d x 1-1/2 2775 2005 12.34 8.92 1970 1425 8.76 6.34<br />

2 - 2-1/8 LSSH20<br />

LSSUI2.06,<br />

LSSU2.1<br />

18 2-1/8 2-1/2 8-13/16 10 10d 7 10d x 1-1/2 2620 1845 11.65 8.21 1860 1310 8.27 5.83<br />

2-1/4 - 2-5/16 LSSH23 LSSUI35 18 2-5/16 2-3/8 8-13/16 10 10d 7 10d x 1-1/2 2620 1845 11.65 8.21 1860 1310 8.27 5.83<br />

2-1/2 LSSH25 LSSUH310 16 2-9/16 2-3/4 8-13/16 14 16d 12 10d x 1-1/2 2985 2250 13.28 10.01 2120 1600 9.43 7.12<br />

2-5/8 LSSH26 -- -- 16 2-11/16 2-5/8 8-13/16 14 16d 12 10d x 1-1/2 2985 2250 13.28 10.01 2120 1600 9.43 7.12<br />

3 LSSH31 LSSU210-2 16 3-1/8 3-3/4 8-13/16 14 16d 12 10d x 1-1/2 3145 2985 13.99 13.28 2235 2120 9.94 9.43<br />

3-1/2 LSSH35 LSSU410 16 3-9/16 3-1/2 8-13/16 14 16d 12 10d x 1-1/2 3145 2985 13.99 13.28 2235 2120 9.94 9.43<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

red font.<br />

W2<br />

W1<br />

W2<br />

LSSH210<br />

3˝<br />

H<br />

W2<br />

3˝<br />

H<br />

<strong>Hangers</strong><br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 103<br />

<strong>USP</strong>2240-131


Skewed 45° <strong>Hangers</strong> – SKH & SKHH series<br />

SKH – Standard 45° skew hanger allows for a 40° to 50° skew range, without hanger<br />

modification.<br />

SKHH – For heavier applications.<br />

Materials: See chart<br />

Finish: G90 galvanizing; SKH26L/R-GC & SKH210L/R-GC – Gold Coat<br />

Options: S KH26L/R, SKH28L/R, SKH210L/R, SKH210L/R-2, SKHH210L/R-2,<br />

SKHH210L/R-2IF, SKHH410L/R, SKHH410L/RIF, SKHH414L/RIF,<br />

SKHH46L/R & SKHH46L/RIF are available in Triple Zinc. To order,<br />

add TZ to stock number, as in SKH26L-TZ.<br />

SKH26L/R & SKH210L/R are available in Stainless Steel. To order,<br />

add SS to stock number, as in SKH26L-SS.<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• The hangers listed are for standard sizes and will accommodate a 40° to 50°<br />

skew range.<br />

• Most sizes do not require a miter cut for installation. Refer to chart<br />

footnote identified with an asterisk.<br />

• Illustrations show left and right skews. (SKH_L = skewed left; SKH_R =<br />

skewed right)<br />

• For I-Joist installations, web stiffeners are required.<br />

• Refer to illustration for staggered I-Joist application for double 2˝, 25/16˝, and<br />

21/2˝ models.<br />

• For double I-Joist installations, web stiffeners between I-Joists are required.<br />

SKH26L<br />

Left skew<br />

SKH26R<br />

Right skew<br />

Typical SKH26L<br />

installation<br />

Left skew<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Right skew<br />

Drive nails<br />

at angle<br />

Left skew<br />

Typical SKH2520R-2<br />

staggered I-Joist installation<br />

Right skew<br />

<strong>Hangers</strong><br />

Dimensions (in)<br />

Fastener Schedule 2,3<br />

Header Joist<br />

Beam /<br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Joist Size<br />

Stock No. Ref. No. Gauge W H D Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

2 x 4 SKH24L/R SUR/L24 16 1-9/16 3-1/4 1-7/8 4 16d 4 10d x 1-1/2 825 1055 3.67 4.69 585 750 2.60 3.34<br />

2 x 6 - 8 SKH26L/R SUR/L26 6 16d 6 10d x 1-1/2 1445 2530 6.43 11.25 1025 1795 4.56 7.98<br />

16 1-9/16 5-1/4 1-7/8<br />

SKH26L/R-GC -- -- 6 N16C-GC 6 N10-GC 1445 2530 6.43 11.25 1025 1795 4.56 7.98<br />

2 x 8 - 10 - 12 SKH28L/R -- -- 16 1-9/16 7-1/4 1-7/8 10 16d 8 10d x 1-1/2 2375 2530 10.56 11.25 1685 1795 7.50 7.98<br />

SUR/L210,<br />

SKH210L/R<br />

2 x 10 - 12 - 14 SUR/L214<br />

16 1-9/16 9-1/4 1-7/8<br />

14 16d 10 10d x 1-1/2 2905 2910 12.92 12.94 2065 2065 9.19 9.19<br />

SKH210L/R-GC -- -- 14 N16C-GC 10 N10-GC 2905 2910 12.92 12.94 2065 2065 9.19 9.19<br />

1 3/4 x 9-1/4 - 14 SKH1720L/R SUR/L1.81/9 16 1-13/16 9-1/8 1-7/8 14 10d 10 10d x 1-1/2 3515 2910 15.64 12.94 2495 2065 11.10 9.19<br />

1-3/4 x 11-1/4 - 18 SKH1724L/R<br />

SUR/L1.81/11,<br />

SUR/L1.81/14<br />

16 1-13/16 11-1/8 1-7/8 16 10d 10 10d x 1-1/2 4740 2910 21.09 12.94 3365 2065 14.97 9.19<br />

2 - 2-1/8 x 9-1/4 - 14 SKH2020L/R<br />

SUR/L2.06/9,<br />

SUR/L2.1/9<br />

16 2-1/8 9 1-7/8 14 10d 10 10d x 1-1/2 2175 2910 9.68 12.94 1545 2065 6.87 9.19<br />

2 - 2-1/8 x 11-1/4 - 18 SKH2024L/R<br />

SUR/L2.06/11,<br />

SUR/L2.1/11<br />

16 2-1/8 11 1-7/8 16 10d 10 10d x 1-1/2 4740 2910 21.09 12.94 3365 2065 14.97 9.19<br />

2-1/4 - 2-5/16 x<br />

9-1/4 - 14<br />

SKH2320L/R SUR/L2.37/9 16 2-3/8 8-7/8 1-7/8 14 10d 10 10d x 1-1/2 2175 2910 9.68 12.94 1545 2065 6.87 9.19<br />

2-1/4 - 2-5/16 x<br />

SUR/L2.37/11,<br />

SKH2324L/R<br />

11-1/4 - 18<br />

SUR/L2.37/14<br />

16 2-3/8 10-7/8 1-7/8 16 10d 10 10d x 1-1/2 4740 2910 21.09 12.94 3365 2065 14.97 9.19<br />

3 x 6 - 8 SKH36L/R -- -- 16 2-9/16 4-3/4 1-3/8 6 16d 6 10d x 1-1/2 1490 2530 6.63 11.25 1060 1795 4.72 7.98<br />

3 x 8 - 10 - 12 SKH38L/R -- -- 16 2-9/16 6-3/4 1-3/8 10 16d 8 10d x 1-1/2 2565 2530 11.41 11.25 1820 1795 8.10 7.98<br />

3 x 10 - 12 - 14 SKH310L/R -- -- 16 2-9/16 8-3/4 1-3/8 14 16d 10 10d x 1-1/2 3265 2910 14.52 12.94 2320 2065 10.32 9.19<br />

3 x 12 - 14 - 16 SKH312L/R -- -- 16 2-9/16 10-3/4 1-3/8 16 16d 10 10d x 1-1/2 3630 2910 16.15 12.94 2575 2065 11.45 9.19<br />

2-1/2 x 9-1/4 - 14 SKH2520L/R SUR/L2.56/9 16 2-9/16 8-5/8 1-7/8 14 10d 10 10d x 1-1/2 3265 2910 14.52 12.94 2320 2065 10.32 9.19<br />

2-1/2 x 11-1/4 - 16 SKH2524L/R<br />

SUR/L2.56/11,<br />

SUR/L2.56/14<br />

16 2-9/16 10-3/4 1-7/8 16 10d 10 10d x 1-1/2 3265 2910 14.52 12.94 2320 2065 10.32 9.19<br />

2-5/8 x 9-1/4 - 14 SKH2620L/R -- -- 16 2-11/16 8-11/16 1-7/8 14 10d 10 10d x 1-1/2 3265 2910 14.52 12.94 2320 2065 10.32 9.19<br />

2-5/8 x 11-1/4 - 16 SKH2624L/R -- -- 16 2-11/16 10-11/16 1-7/8 16 10d 10 10d x 1-1/2 3265 2910 14.52 12.94 2320 2065 10.32 9.19<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

DF-L (Lbs)<br />

Factored Resistance<br />

DF-L (kN)<br />

S-P-F (Lbs)<br />

S-P-F (kN)<br />

continued on next page<br />

104<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


SKH210L/R 14 16d 10 10d x 1-1/2 2905 2910 12.92 12.94 2065 2065 9.19 9.19<br />

2 x 10 - 12 - 14 16 1-9/16 9-1/4 1-7/8<br />

1-3/4 x 11-1/4 - 18 SKH1724L/R<br />

16 1-13/16 11-1/8 1-7/8 16 10d 10 10d x 1-1/2 4740 2910 21.09 12.94 3365 2065 14.97 9.19<br />

SUR/L1.81/14<br />

Skewed 45° <strong>Hangers</strong> – SKH & SKHH series continued<br />

2 - 2-1/8 x 9-1/4 - 14 SKH2020L/R 16 2-1/8 9 1-7/8 14 10d 10 10d x 1-1/2 2175 2910 9.68 12.94 1545 2065 6.87 9.19<br />

2 - 2-1/8 x 11-1/4 - 18 SKH2024L/R 16 2-1/8 11 1-7/8 16 10d 10 10d x 1-1/2 4740 2910 21.09 12.94 3365 2065 14.97 9.19<br />

SKH2320L/R SUR/L2.37/9 16 2-3/8 8-7/8 1-7/8 14 10d 10 10d x 1-1/2 2175 2910 9.68 12.94 1545 2065 6.87 9.19<br />

SKH2324L/R 16 2-3/8 10-7/8 1-7/8 16 10d 10 10d x 1-1/2 4740 2910 21.09 12.94 3365 2065 14.97 9.19<br />

H H<br />

H H<br />

H<br />

2-1/2 x 11-1/4 - 16 SKH2524L/R<br />

D<br />

W<br />

SKH210L<br />

SUR/L2.56/14<br />

D<br />

16 2-9/16 10-3/4 1-7/8 16 10d 10 10d x 1-1/2 3265 2910 14.52 12.94 2320 2065 10.32 9.19<br />

D<br />

W<br />

W<br />

W<br />

W D<br />

SKH210R SKHH210L<br />

SKHH210L-2 SKH2520R-2<br />

D<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Dimensions (in)<br />

Fastener Schedule 2,3<br />

Factored Resistance<br />

Header<br />

Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Beam /<br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Joist Size<br />

Stock No. Ref. No. Gauge W H D Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

(2) 2 x 6 - 8 SKH26L/R-2 * SUR/L26-2 16 3-1/16 4-1/2 1-3/8 6 16d 6 10d 1795 2530 7.98 11.25 1275 1795 5.67 7.98<br />

(2) 2 x 8 - 10 - 12 SKH28L/R-2 * -- -- 16 3-1/16 6-1/2 1-3/8 10 16d 8 10d 3920 2530 17.44 11.25 2785 1795 12.39 7.98<br />

(2) 2 x 10 - 12 - 14 SKH210L/R-2 * SUR/L210-2 16 3-1/16 8-1/2 1-3/8 14 16d 10 10d 5065 3565 22.53 15.86 3595 2530 15.99 11.25<br />

(2) 2 x 12 - 14 - 16 SKH212L/R-2 * SUR/L214-2 16 3-1/16 10-1/2 1-3/8 16 16d 10 10d 4930 3565 21.90 15.90 3500 2530 15.60 11.25<br />

3-1/2 x 8 - 14 SKH410L/R * SUR/L410 14 3-9/16 8-1/2 2-1/2 16 16d 10 16d 3690 3560 16.41 15.84 2620 2530 11.65 11.25<br />

3-1/2 x 12 - 18 SKH414L/R * SUR/L414 14 3-9/16 12-1/2 2-1/2 22 16d 10 16d 7405 3560 32.94 15.84 5260 2530 23.40 11.25<br />

4 x 6 - 8 SKH46L/R * SUR/L46 14 3-9/16 4-3/4 2-1/2 10 16d 6 16d 2575 2530 11.45 11.25 1830 1795 8.14 7.98<br />

4 x 10 - 12 - 14 SKH410L/R * SUR/L410 14 3-9/16 8-1/2 2-1/2 16 16d 10 16d 3690 3560 16.41 15.84 2620 2530 11.65 11.25<br />

4 x 14 - 16 - 18 SKH414L/R * SUR/L414 14 3-9/16 12-1/2 2-1/2 22 16d 10 16d 7405 3560 32.94 15.84 5260 2530 23.40 11.25<br />

(2) 2 - 2-1/8 x<br />

HSUR/L4.12/9,<br />

SKH2020L/R-2 *<br />

9-1/4 - 14<br />

HSUR/L4.28/9<br />

14 4-3/16 9-1/4 3-1/2 14 10d 10 10d 5430 3565 24.15 15.86 3855 2530 17.15 11.25<br />

(2) 2 - 2-1/8 x<br />

11-1/4 - 18<br />

SKH2024L/R-2 *<br />

HSUR/L4.12/11,<br />

HSUR/L4.12/14,<br />

HSUR/L4.12/16,<br />

HSUR/L4.28/11<br />

14 4-3/16 11-1/4 3-1/2 16 10d 10 10d 5055 3560 22.49 15.84 3590 2530 15.97 11.25<br />

(2) 2-5/16 x 9-1/4 - 14 SKH2320L/R-2 * HSUR/L4.75/9 14 4-7/8 9-1/4 3-1/2 14 10d 10 10d 5430 3565 24.15 15.86 3855 2530 17.15 11.25<br />

(2) 2-5/16 x<br />

11-1/4 - 18<br />

SKH2324L/R-2 *<br />

HSUR/L4.75/11,<br />

HSUR/L4.75/14,<br />

HSUR/L4.75/16<br />

14 4-7/8 11-1/4 3-1/2 16 10d 10 10d 5055 3560 22.49 15.84 3590 2530 15.97 11.25<br />

(2) 2-1/2 x 9-1/4 - 14 SKH2520L/R-2 * HSUR/L5.12/9 14 5-1/8 9-1/4 3-1/2 14 10d 10 10d 5430 3565 24.15 15.86 3855 2530 17.15 11.25<br />

HSUR/L5.12/11,<br />

(2) 2-1/2 x 11-1/4 - 16 SKH2524L/R-2 * HSUR/L5.12/14, 14 5-1/8 11-1/4 3-1/2 16 10d 10 10d 5055 3560 22.49 15.84 3590 2530 15.97 11.25<br />

HSUR/L5.12/16<br />

2 x 6 - 8 SKHH26L/R -- -- 14 1-5/8 5-1/8 3-1/4 18 16d 12 10d x 1-1/2 2195 2370 9.76 10.54 1880 2045 8.36 9.10<br />

2 x 8 - 10 - 12 SKHH28L/R -- -- 14 1-5/8 7 3-1/4 26 16d 16 10d x 1-1/2 3170 3155 14.10 14.03 2720 2730 12.10 12.14<br />

2 x 10 - 12 - 14 SKHH210L/R -- -- 14 1-5/8 9 4-1/4 34 16d 20 10d x 1-1/2 4140 3940 18.42 17.53 3555 3410 15.81 15.17<br />

(2) 2 x 6 - 8<br />

SKHH26L/R-2 HSUR/L26-2 14 3-1/16 5-1/4 2 12 16d 4 16d x 2-1/2 2435 935 10.83 4.16 2090 805 9.30 3.58<br />

SKHH26L/R-2IF HSUR/LC26-2 14 3-1/16 5-1/4 2 12 16d 4 16d x 2-1/2 2435 935 10.83 4.16 2090 805 9.30 3.58<br />

HSUR/L210-2,<br />

SKHH210L/R-2<br />

(2) 2 x 10 - 12 - 14<br />

HSUR/L214-2<br />

14 3-1/16 8-1/2 2 20 16d 6 16d x 2-1/2 4060 1400 18.06 6.23 3485 1200 15.50 5.34<br />

SKHH210L/R-2IF HSUR/LC210-2 14 3-1/16 8-1/2 2 20 16d 6 16d x 2-1/2 4060 1400 18.06 6.23 3485 1200 15.50 5.34<br />

4 x 6 - 8<br />

4 x 10 - 12 - 14<br />

4 x 14 - 16 - 18<br />

SKHH46L/R<br />

SKHH410L/R<br />

SKHH414L/R<br />

HSUR/L46<br />

HSUR/L410<br />

HSUR/L414<br />

14<br />

14<br />

14<br />

3-9/16<br />

3-9/16<br />

3-9/16<br />

5-1/4<br />

8-1/2<br />

12-1/2<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

12<br />

20<br />

26<br />

16d<br />

16d<br />

16d<br />

6<br />

10<br />

10<br />

16d<br />

16d<br />

16d<br />

2435<br />

4060<br />

5280<br />

1400<br />

2335<br />

2335<br />

10.83<br />

18.06<br />

23.49<br />

6.23<br />

10.39<br />

10.39<br />

2090<br />

3485<br />

4530<br />

1200<br />

2005<br />

2005<br />

9.30<br />

15.50<br />

20.15<br />

5.34<br />

8.92<br />

8.92<br />

SKHH46L/RIF<br />

SKHH410L/RIF<br />

SKHH414L/RIF<br />

HSUR/LC46<br />

HSUR/LC410<br />

HSUR/LC414<br />

14<br />

14<br />

14<br />

3-9/16<br />

3-9/16<br />

3-9/16<br />

5-1/4<br />

8-1/2<br />

12-1/2<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

12<br />

20<br />

26<br />

16d<br />

16d<br />

16d<br />

6<br />

10<br />

10<br />

16d<br />

16d<br />

16d<br />

2435<br />

4060<br />

5280<br />

1400<br />

2335<br />

2335<br />

10.83<br />

18.06<br />

23.49<br />

6.23<br />

10.39<br />

10.39<br />

2090<br />

3485<br />

4530<br />

1200<br />

2005<br />

2005<br />

9.30<br />

15.50<br />

20.15<br />

5.34<br />

8.92<br />

8.92<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

<br />

red font.<br />

Light Slope <strong>Hangers</strong> – LS series<br />

The LS hanger slopes from 0° to 30° down (0 to 7:12 pitch down).<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• The LS can be field adjusted to slopes from 0° to 30° down.<br />

Dimensions (in)<br />

Fastener Schedule 2,4<br />

Header<br />

W<br />

Factored Resistance<br />

LS268<br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Joist Size Stock No. Ref. No. Gauge W H Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

2 x 6 - 8<br />

LS268 -- -- 18 1-9/16 5-1/2 7 16d 7 10d x 1-1/2 1370 840 6.09 3.74 1180 720 5.25 3.20<br />

LS210 -- -- 18 1-9/16 7-7/8 9 16d 9 10d x 1-1/2 1765 1290 7.85 5.74 1520 1110 6.76 4.94<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) A tie strap is required for all installations when sloped down at 7/12 to 12/12 pitch - use LSTA24 with (4) 10d x 1-1/2 nails per end.<br />

4) NAILS:<br />

Joist<br />

DF-L (Lbs)<br />

DF-L (kN)<br />

S-P-F (Lbs)<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 105<br />

<strong>USP</strong>2240-131<br />

3˝<br />

H<br />

S-P-F (kN)<br />

Typical LS268<br />

installation<br />

<strong>Hangers</strong>


Heavy-Duty Welded Universal <strong>Hangers</strong> – HWUH series<br />

Versatile heavy-duty top flange hanger attaches to both<br />

wood and masonry. Unique design allows builders to use<br />

one style hanger on the job when the structure has a<br />

variety of support materials.<br />

Materials: Top Flange – 1/4˝ steel; Stirrup – 7 gauge<br />

Finish: <strong>USP</strong> primer<br />

Options: See Specialty Options Chart on page 107.<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• NA21 nails are included with hangers where specified.<br />

• NA21 nails are not recommended for use with LVL,<br />

PSL, or LSL headers.<br />

• Masonry design load values apply to both solid concrete<br />

tie beams and grout-filled CMU walls.<br />

• Alternate installation – Use (2) 1/2˝ x 4˝ Powers<br />

Fasteners Wedge-Bolts ® or equal for loads up to 2,400 lbs.<br />

when attaching to CMU. Loads shall not exceed table loads.<br />

NEW<br />

10˝<br />

3 1 /2˝<br />

3 1 /2˝<br />

H<br />

W<br />

3 1 /2˝<br />

HWUH410<br />

Typical HWUH410<br />

wood-to-wood installation<br />

Typical HWUH410<br />

wood-to-masonry installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>Hangers</strong><br />

Beam/<br />

Joist Size<br />

<strong>USP</strong><br />

Stock No.<br />

2 x 4 - 6 HWUH26 -- -- 1-5/8<br />

2 x 8 HWUH28 -- --<br />

2 x 10<br />

HWUH210 -- --<br />

2 x 12 HWUH212 -- --<br />

2 x 14 HWUH214 -- --<br />

2 x 16 HWUH216 -- --<br />

3 x 6 HWUH36 -- --<br />

3 x 8 HWUH38 -- --<br />

3 x 10 HWUH310 -- --<br />

3 x 12 HWUH312 -- --<br />

3 x 14 HWUH314 -- --<br />

3 x 16<br />

Dimensions (in)<br />

Fastener Schedule 2,3<br />

Factored Resistance<br />

Header<br />

Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Ref. No. W H Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

1-5/8<br />

1-5/8<br />

1-5/8<br />

1-5/8<br />

1-5/8<br />

2-5/8<br />

2-5/8<br />

2-5/8<br />

2-5/8<br />

2-5/8<br />

3-1/8<br />

3-1/8<br />

3-1/8<br />

3-1/8<br />

5-3/8<br />

7-1/8<br />

9-1/8<br />

11<br />

13<br />

16<br />

5-3/8<br />

7-1/8<br />

9-1/8<br />

11<br />

13<br />

16<br />

5-3/8<br />

7-1/8<br />

9-1/8<br />

11<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

6700<br />

6700<br />

6700<br />

6700<br />

6700<br />

6700<br />

6700<br />

6700<br />

6700<br />

6700<br />

6700<br />

6700<br />

6700<br />

6700<br />

6700<br />

6700<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

29.80<br />

29.80<br />

29.80<br />

29.80<br />

29.80<br />

29.80<br />

29.80<br />

29.80<br />

29.80<br />

29.80<br />

29.80<br />

29.80<br />

29.80<br />

29.80<br />

29.80<br />

29.80<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

4760<br />

4760<br />

4760<br />

4760<br />

4760<br />

4760<br />

4760<br />

4760<br />

4760<br />

4760<br />

4760<br />

4760<br />

4760<br />

4760<br />

4760<br />

4760<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

21.17<br />

21.17<br />

21.17<br />

21.17<br />

21.17<br />

21.17<br />

21.17<br />

21.17<br />

21.17<br />

21.17<br />

21.17<br />

21.17<br />

21.17<br />

21.17<br />

21.17<br />

21.17<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

HWUH316 -- -- 2-5/8<br />

(2) 2 x 6 HWUH26-2 -- --<br />

(2) 2 x 8 HWUH28-2 -- --<br />

(2) 2 x 10 HWUH210-2 -- --<br />

(2) 2 x 12 HWUH212-2 -- --<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

red font.<br />

continued on next page<br />

106<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Heavy-Duty Welded Universal <strong>Hangers</strong> – HWUH series cont.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Dimensions (in)<br />

Fastener Schedule 2,3<br />

Factored Resistance<br />

Header<br />

Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Beam/ <strong>USP</strong><br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Joist Size Stock No. Ref. No. W H Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

(2) 2 x 14 HWUH214-2<br />

(2) 2 x 16 HWUH216-2<br />

-- --<br />

-- --<br />

3-1/8<br />

3-1/8<br />

13<br />

16<br />

6<br />

6<br />

10d<br />

10d<br />

4<br />

4<br />

10d<br />

10d<br />

6700<br />

6700<br />

1240<br />

1240<br />

29.80<br />

29.80<br />

5.52<br />

5.52<br />

4760<br />

4760<br />

1090<br />

1090<br />

21.17<br />

21.17<br />

4.85<br />

4.85<br />

2<br />

2<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

4<br />

4<br />

10d<br />

10d<br />

5010<br />

5010<br />

2035<br />

2035<br />

22.29<br />

22.29<br />

9.05<br />

9.05<br />

3555<br />

3555<br />

1445<br />

1445<br />

15.81<br />

15.81<br />

6.43<br />

6.43<br />

4 x 6<br />

4 x 8<br />

4 x 10<br />

4 x 12<br />

4 x 14<br />

4 x 16<br />

6 x 6<br />

6 x 8<br />

6 x 10<br />

6 x 12<br />

6 x 14<br />

6 x 16<br />

8 x 6<br />

8 x 8<br />

8 x 10<br />

8 x 12<br />

8 x 14<br />

8 x 16<br />

HWUH46<br />

HWUH48<br />

HWUH410<br />

HWUH412<br />

HWUH414<br />

HWUH416<br />

HWUH66<br />

HWUH68<br />

HWUH610<br />

HWUH612<br />

HWUH614<br />

HWUH616<br />

HWUH86<br />

HWUH88<br />

HWUH810<br />

HWUH812<br />

HWUH814<br />

HWUH816<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

3-9/16<br />

3-9/16<br />

3-9/16<br />

3-9/16<br />

3-9/16<br />

3-9/16<br />

5-1/2<br />

5-1/2<br />

5-1/2<br />

5-1/2<br />

5-1/2<br />

5-1/2<br />

7-1/2<br />

7-1/2<br />

7-1/2<br />

7-1/2<br />

7-1/2<br />

7-1/2<br />

5-3/8<br />

7-1/8<br />

9-1/8<br />

11<br />

13<br />

16<br />

5-3/8<br />

7-1/8<br />

9-1/8<br />

11<br />

13<br />

16<br />

5-3/8<br />

7-1/8<br />

9-1/8<br />

11<br />

13<br />

16<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

6<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

NA21<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

8625<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

1240<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

38.37<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

5.52<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

6125<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

1090<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

27.25<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

4.85<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

2<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

1/2 x 6 Emb. J-Bolt<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

4<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

10d<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

5010<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

2035<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

22.29<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

9.05<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

3555<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

1445<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

15.81<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

6.43<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

red font.<br />

Specialty Options Chart – refer to Specialty Options pages 210 and 212 for additional details.<br />

Option Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Top Flange Offset Saddle<br />

Range <br />

<br />

Factored<br />

Resistance<br />

Ordering<br />

<br />

SK, <br />

(R) (L),<br />

<br />

<br />

<br />

SL, <br />

(U) (D),<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Hanger Width<br />

<br />

<br />

<br />

% of table load:<br />

<br />

<br />

<br />

OS, <br />

(R) (L),<br />

<br />

<br />

<br />

<br />

SA, <br />

<br />

<br />

<br />

<strong>Hangers</strong><br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 107<br />

<strong>USP</strong>2240-131


Masonry <strong>Hangers</strong> – MPH series<br />

These hangers are designed to support standard lumber joists,<br />

I-Joists, or beams. Easy installation into concrete block walls makes the<br />

MPH an attractive alternative to fabricating seats in masonry (or<br />

attaching ledgers) to support joists or beams.<br />

Install with (2) 16d<br />

duplex nails in<br />

grouted cells<br />

Materials: 12 gauge<br />

Finish: <strong>USP</strong> primer<br />

Options: All nominal lumber sizes are available for<br />

rough/full size lumber. See Specialty Options<br />

Chart.<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• 16d duplex nails are not supplied with MPH hangers.<br />

• Place hanger into position on top of concrete block. Install (2) 16d duplex<br />

nails (8 gauge or 0.162˝ dia. x 31⁄2˝ double head) through the top flange<br />

nail holes. Then continue laying the next course of block.<br />

• A minimum of one course shall be laid over hanger top flange and one<br />

course below hanger top flange. Courses adjacent to the top flange shall<br />

be subsequently grouted.<br />

• These products do not provide uplift resistance.<br />

Install with (2) 16d<br />

duplex nails in<br />

grouted cells<br />

Typical MPH<br />

single ply installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>Hangers</strong><br />

Dimensions (in)<br />

Fastener Schedule 2,4 Factored Resistance (100%) 1<br />

Beam/ <strong>USP</strong><br />

Steel<br />

Vertical Vertical<br />

Joist Size Stock No. Ref. No. Gauge W H L Qty Type Qty Type Lbs kN Lbs kN<br />

2 x 10 MPH210 WM210 12 1-9/16 9-1/4 7 2 16d duplex 2 10d x 1-1/2 3745 16.66 3220 14.32<br />

2 x 12 MPH212 WM212 12 1-9/16 11-1/4 7 2 16d duplex 2 10d x 1-1/2 3745 16.66 3220 14.32<br />

2 x 14 MPH214 WM214 12 1-9/16 13-1/8 7 2 16d duplex 2 10d x 1-1/2 3745 16.66 3220 14.32<br />

2 x 16 MPH216 WM216 12 1-9/16 15-1/8 7 2 16d duplex 2 10d x 1-1/2 3745 16.66 3220 14.32<br />

(2) 2 x 10 MPH210-2 WM210-2 12 3-1/8 9-1/4 7 2 16d duplex 2 10d 6165 27.42 5300 23.58<br />

(2) 2 x 12 MPH212-2 WM212-2 12 3-1/8 11-1/4 7 2 16d duplex 2 10d 6165 27.42 5300 23.58<br />

(2) 2 x 14 MPH214-2 WM214-2 12 3-1/8 13-1/8 7 2 16d duplex 2 10d 6165 27.42 5300 23.58<br />

(2) 2 x 16 MPH216-2 WM216-2 12 3-1/8 15-1/8 7 2 16d duplex 2 10d 6165 27.42 5300 23.58<br />

3 x 10 MPH310 WM310 12 2-9/16 9-1/4 7 2 16d duplex 2 10d x 1-1/2 4665 20.75 4010 17.84<br />

3 x 12 MPH312 WM312 12 2-9/16 11-1/4 7 2 16d duplex 2 10d x 1-1/2 4665 20.75 4010 17.84<br />

3 x 14 MPH314 WM314 12 2-9/16 13-1/8 7 2 16d duplex 2 10d x 1-1/2 4665 20.75 4010 17.84<br />

3 x 16 MPH316 WM316 12 2-9/16 15-1/8 7 2 16d duplex 2 10d x 1-1/2 4665 20.75 4010 17.84<br />

4 x 10 MPH410 WM410 12 3-9/16 9-1/4 7 2 16d duplex 2 10d 6165 27.42 5300 23.58<br />

4 x 12 MPH412 WM412 12 3-9/16 11-1/4 7 2 16d duplex 2 10d 6165 27.42 5300 23.58<br />

4 x 14 MPH414 WM414 12 3-9/16 13-1/8 7 2 16d duplex 2 10d 6165 27.42 5300 23.58<br />

4 x 16 MPH416 WM416 12 3-9/16 15-1/8 7 2 16d duplex 2 10d 6165 27.42 5300 23.58<br />

6 x 10 MPH610 WM610 12 5-9/16 9-1/4 7 2 16d duplex 2 10d 6165 27.42 5300 23.58<br />

Glulam Sizes<br />

3-1/8 x glulam MPH325 -- -- 12 3-1/4 specify 7 2 16d duplex 2 10d 6165 27.42 5300 23.58<br />

5-1/8 x glulam MPH525 -- -- 12 5-1/4 specify 7 2 16d duplex 2 10d 6165 27.42 5300 23.58<br />

1) Masonry compressive strength shall be minimum 1500 psi.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) "Specify" denotes the required supported beam height that must be specified at the time of ordering.<br />

4) NAILS:<br />

double headed nails and shall be installed in grouted cells in accordance to manufacturer's installation specifications.<br />

Specialty Options Chart – refer to Specialty Options pages 210 and 212 for additional details.<br />

Option Skewed 1 Sloped Seat 2 Sloped / Skewed 1,2 Top Flange Offset<br />

Range <br />

<br />

Hanger Width % of table value:<br />

Factored<br />

60%<br />

<br />

Resistance<br />

75%<br />

85%<br />

Ordering<br />

SK, <br />

(R) (L),<br />

<br />

<br />

SL, <br />

(U) (D),<br />

<br />

<br />

Block<br />

<br />

<br />

<br />

<br />

Joist<br />

DF-L<br />

OS, <br />

(R) (L),<br />

<br />

<br />

S-P-F<br />

Typical MPH<br />

double ply installation<br />

W<br />

MPH<br />

L<br />

H<br />

3 3 /4˝<br />

2 1 /2˝<br />

108<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


UNIVERSAL MASONRY HANGERS – UMH SERIES<br />

A versatile solution for hanging beams from masonry walls.<br />

Face mount design allows hanger to be used with beam<br />

heights from 16˝ to 24˝. Available in a variety of widths<br />

for solid sawn, glulam, or engineered lumber beams.<br />

Materials: 1/4˝ steel<br />

Finish: <strong>USP</strong> primer<br />

Codes: Load values derived from data submitted to various<br />

North American building code evaluators.<br />

NEW<br />

5 1 /4˝ Min.<br />

edge distance<br />

2 3 /4˝ bolts.<br />

(see footnote 2)<br />

Bond beam with<br />

(1) #5 rebar continuous<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Fully grouted and reinforced concrete block or cast-in-place<br />

concrete with a minimum of (1) #5 rebar continuous to<br />

footing with standard hook at bolt locations.<br />

• Minimum joist bearing length is 31/2˝.<br />

Typical UMH<br />

installation<br />

3 1 /2˝ Min.<br />

joist bearing<br />

15 1/2˝<br />

5˝<br />

W<br />

UMH<br />

Fastener Schedule<br />

Factored Resistance<br />

Header 2,3 Joist 4,5 Cast-in-Place Cast-in-Place<br />

Masonry (Lbs) Masonry (kN)<br />

Concrete (Lbs) Concrete (Lbs)<br />

2500 psi 2500 psi<br />

3000 psi 3000 psi<br />

<strong>USP</strong><br />

Steel W Bolt<br />

Wood<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Stock No. Ref. No. Gauge (in) Qty Dia. (in) Qty Type Species 100% 115% 100% 115% 100% 115% 100% 115%<br />

UMH358<br />

<br />

DF-L 11875 8205 52.82 36.50 11875 8205 52.82 36.50<br />

3 3-5/8 2 3/4 16 16d<br />

<br />

S-P-F 8430 5825 37.50 25.91 8430 5825 37.50 25.91<br />

UMH458<br />

UMH538<br />

-- --<br />

-- --<br />

3<br />

3<br />

4-5/8<br />

5-3/8<br />

2<br />

2<br />

3/4<br />

3/4<br />

16<br />

16<br />

16d<br />

16d<br />

DF-L<br />

DF-L<br />

11875<br />

11875<br />

8205<br />

8205<br />

52.82<br />

52.82<br />

36.50<br />

36.50<br />

11875<br />

11875<br />

8205<br />

8205<br />

52.82<br />

52.82<br />

36.50<br />

36.50<br />

S-P-F<br />

S-P-F<br />

8430<br />

8430<br />

5825<br />

5825<br />

37.50<br />

37.50<br />

25.91<br />

25.91<br />

8430<br />

8430<br />

5825<br />

5825<br />

37.50<br />

37.50<br />

25.91<br />

25.91<br />

UMH558<br />

<br />

DF-L 11875 8205 52.82 36.50 11875 8205 52.82 36.50<br />

3 5-5/8 2 3/4 16 16d<br />

<br />

S-P-F 8430 5825 37.50 25.91 8430 5825 37.50 25.91<br />

UMH718 -- -- 3 7-1/8 2 3/4 16 16d<br />

DF-L 11875 8205 52.82 36.50 11875 8205 52.82 36.50<br />

S-P-F 8430 5825 37.50 25.91 8430 5825 37.50 25.91<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

<br />

<br />

<br />

<br />

5) NAILS:<br />

red font.<br />

<strong>Hangers</strong><br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 109<br />

<strong>USP</strong>2240-131


PANEL HANGERS – FHD26<br />

FHD – Straddles the header and receives a joist from both sides.<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• In panelized construction, installers are allowed to nail through<br />

both the sheathing and the hanger top flange with (1) 10d nail.<br />

The nail should be centered in the top flange and be no closer<br />

than 1/4˝ from the back or front edge of the top flange.<br />

NEW<br />

Dimensions (in)<br />

Fastener Schedule 3,5<br />

Factored Resistance<br />

Header<br />

Joist<br />

DF-L<br />

S-P-F<br />

Joist <strong>USP</strong><br />

Steel<br />

Top Face Uplift 2 Uplift 2<br />

Size Stock No. Ref. No. Gauge W H D TF 4 Qty Qty Type Qty Type Unit 100% 115% 100% 115%<br />

Lbs 1575 335 1120 235<br />

FHD26 -- -- 18 5-3/8 1-1/2 specify 2 2 2 10d x 1-1/2<br />

kN 7.01 1.49 4.98 1.05<br />

1) Loads listed are per side.<br />

2) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) "Specify" denotes the required top flange width that must be specified at the time of ordering.<br />

5) NAILS:<br />

<br />

New products or updated product information are designated in red font.<br />

PURLIN HANGERS – JPF SERIES<br />

W<br />

3 3 /4˝<br />

H<br />

D<br />

FHD<br />

TF<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: 20 gauge<br />

Finish: G90 galvanizing<br />

Options: JPF24 and JPF26 are available<br />

in Triple Zinc. To order, add TZ to<br />

stock number, as in JPF24-TZ.<br />

Codes: Load values are derived from<br />

data submitted to various North<br />

American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page<br />

10.<br />

• Diamond holes allow optional header nailing.<br />

• Joist nails must be driven at a 30° to 45° angle<br />

through the purlin into the header to achieve listed<br />

loads. Standard length “double shear” nails must<br />

be used to achieve listed load values.<br />

• 16d sinkers (9 gauge x 3 1/4˝) may be used where<br />

10d commons are specified with no load reduction.<br />

Raised<br />

dimple allows<br />

30º to 45˚<br />

nailing<br />

Typical JPF24<br />

installation<br />

W 1 1/2˝<br />

JPF24<br />

NEW<br />

H<br />

TF<br />

Typical JPF24<br />

back-to-back installation<br />

Double shear nail<br />

design features<br />

fewer nails and<br />

faster installation<br />

Uses standard<br />

length nails<br />

<strong>Hangers</strong><br />

Purlin<br />

Size<br />

<strong>USP</strong><br />

Stock No.<br />

JPF24<br />

JPF26 PF26 20<br />

Dimensions (in) Fastener Schedule 3,4<br />

Factored Resistance<br />

Header 2 Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Steel<br />

Top Face Floor Uplift 1 Floor Uplift 1 Floor Uplift 1 Floor Uplift 1<br />

Ref. No. Gauge W H TF Qty Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

PF24 20 1-9/16<br />

1-9/16<br />

3-3/8<br />

5-3/8<br />

1-1/16<br />

1-1/16<br />

2<br />

2<br />

-- --<br />

-- --<br />

10d<br />

10d<br />

2<br />

2<br />

10d<br />

10d<br />

1755<br />

1755<br />

675<br />

675<br />

7.81<br />

7.81<br />

3.00<br />

3.00<br />

1245<br />

1245<br />

480<br />

480<br />

5.54<br />

5.54<br />

2.14<br />

2.14<br />

2<br />

2<br />

2<br />

2<br />

10d<br />

10d<br />

2<br />

2<br />

10d<br />

10d<br />

1995<br />

1995<br />

890<br />

890<br />

8.87<br />

8.87<br />

3.96<br />

3.96<br />

1420<br />

1420<br />

630<br />

630<br />

6.32<br />

6.32<br />

2.80<br />

2.80<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) JPF cannot be used back to back on a single ply header when optional nailing is used.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) NAILS:<br />

New products or updated product information are designated in red font.<br />

110<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


UNDERSADDLE HANGERS – TUS & DTUS SERIES<br />

TUS – For a single ply purlin.<br />

DTUS – For a single ply purlin with a 2-ply saddle dimension.<br />

Uplift<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: 20 gauge<br />

Finish: G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Attachs with standard 11/2˝ joist hanger nails that can be<br />

installed with a positive placement nail gun or be<br />

hand driven.<br />

• Other 1-1/2˝ fasteners with a shear value equal or greater<br />

than a 10d nail may be used.<br />

NEW<br />

Typical TUS24<br />

installation<br />

F2<br />

F2<br />

Typical DTUS24<br />

installation<br />

Bottom<br />

View<br />

H<br />

H<br />

W<br />

TUS24S<br />

W<br />

3¼"<br />

DTUS24<br />

W<br />

H<br />

W<br />

TUS24<br />

W<br />

Joist Size<br />

2 x 4 - 6<br />

<br />

2 x 4 - 6<br />

saddle<br />

2 x 4 - 6<br />

saddle<br />

<strong>USP</strong><br />

Stock No.<br />

TUS24S<br />

TUS24<br />

DTUS24<br />

Dimensions (in)<br />

Fastener Schedule 2,3 Factored Resistance 1<br />

Header<br />

Joist<br />

DF-L (Lbs)<br />

S-P-F (Lbs)<br />

Steel<br />

Qty<br />

Qty<br />

Download Uplift 1 F2 Download Uplift 1 F2<br />

Ref. No. Gauge W H Face Bottom Type Face Bottom Type Unit 100% 115% 115% 100% 115% 115%<br />

-- --<br />

-- --<br />

-- --<br />

20<br />

20<br />

20<br />

1-9/16<br />

1-9/16<br />

1-9/16<br />

3<br />

3<br />

3<br />

4<br />

4<br />

4<br />

1<br />

1<br />

1<br />

8d x 1-1/2<br />

10d x 1-1/2<br />

LL915<br />

8d x 1-1/2<br />

10d x 1-1/2<br />

LL915<br />

8d x 1-1/2<br />

10d x 1-1/2<br />

LL915<br />

4<br />

4<br />

4<br />

1<br />

1<br />

1<br />

8d x 1-1/2<br />

10d x 1-1/2<br />

LL915<br />

8d x 1-1/2<br />

10d x 1-1/2<br />

LL915<br />

8d x 1-1/2<br />

10d x 1-1/2<br />

LL915<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

Lbs<br />

980<br />

980<br />

980<br />

980<br />

980<br />

980<br />

980<br />

980<br />

980<br />

955<br />

955<br />

955<br />

955<br />

955<br />

955<br />

955<br />

955<br />

955<br />

385<br />

385<br />

385<br />

1120<br />

1120<br />

1120<br />

1120<br />

1120<br />

1120<br />

695<br />

695<br />

695<br />

695<br />

695<br />

695<br />

695<br />

695<br />

695<br />

680<br />

680<br />

680<br />

680<br />

680<br />

680<br />

680<br />

680<br />

680<br />

275<br />

275<br />

275<br />

795<br />

795<br />

795<br />

795<br />

795<br />

795<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

kN<br />

4.36<br />

4.36<br />

4.36<br />

4.36<br />

4.36<br />

4.36<br />

4.36<br />

4.36<br />

4.36<br />

4.25<br />

4.25<br />

4.25<br />

4.25<br />

4.25<br />

4.25<br />

4.25<br />

4.25<br />

4.25<br />

1.71<br />

1.71<br />

1.71<br />

4.98<br />

4.98<br />

4.98<br />

4.98<br />

4.98<br />

4.98<br />

3.09<br />

3.09<br />

3.09<br />

3.09<br />

3.09<br />

3.09<br />

3.09<br />

3.09<br />

3.09<br />

3.02<br />

3.02<br />

3.02<br />

3.02<br />

3.02<br />

3.02<br />

3.02<br />

3.02<br />

3.02<br />

1.22<br />

1.22<br />

1.22<br />

3.54<br />

3.54<br />

3.54<br />

3.54<br />

3.54<br />

3.54<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

red font.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 111<br />

<strong>USP</strong>2240-131<br />

<strong>Hangers</strong>


Purlin <strong>Hangers</strong> – JDS series<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from<br />

data ubmitted to various North<br />

American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Joist nails must be driven at a 30° to 45° angle through the<br />

purlin into the header to achieve listed loads. Standard length<br />

“double shear” nails must be used to achieve listed load<br />

values.<br />

1 3 /4˝<br />

Header<br />

Top opening of<br />

starburst prong<br />

provides a<br />

witness hole<br />

Typical JDS26<br />

installation<br />

NEW<br />

H<br />

TF<br />

W<br />

JDS24S<br />

H<br />

TF<br />

W<br />

Raised dimple<br />

allows 30˚ to<br />

45˚ nailing<br />

Starburst prong<br />

for temporary<br />

attachment to<br />

truss<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Typical JDS24S<br />

installation<br />

JDS26-175<br />

installation<br />

JDS26-175<br />

JDS26<br />

(JDS24 similar)<br />

Raised dimple<br />

allows 30˚ to<br />

45˚ nailing<br />

Double shear nail<br />

design features<br />

fewer nails and<br />

faster installation<br />

Uses standard<br />

length nails<br />

<strong>Hangers</strong><br />

Purlin<br />

Size<br />

2 x 4<br />

<br />

2 x 6<br />

<br />

2 x 4<br />

saddle<br />

2 x 6<br />

saddle<br />

Dimensions (in)<br />

Fastener Schedule 2,3<br />

Factored Resistance<br />

Header Each Purlin DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

<strong>USP</strong><br />

Steel<br />

Top Face Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Stock No. Ref. No. Gauge W H TF Qty Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

JDS24S Min 1 2 10d x 1-1/2 2 10d x 1-1/2 785 340 3.49 1.51 560 245 2.49 1.09<br />

PF24A 18 1-9/16 3-1/2 3/4<br />

JDS24S Max 2 -- -- 10d x 1-1/2 2 10d 945 640 4.20 2.85 670 455 2.98 2.02<br />

JDS26S Min 1 2 10d x 1-1/2 4 10d x 1-1/2 905 665 4.03 2.96 640 470 2.85 2.09<br />

PF26A 18 1-9/16 5-1/2 3/4<br />

JDS26S Max 2 -- -- 10d x 1-1/2 4 10d 1365 730 6.07 3.25 970 520 4.31 2.31<br />

JDS24 Min 2 4 10d x 1-1/2 2 10d x 1-1/2 1575 685 7.01 3.05 1120 485 4.98 2.16<br />

PFD24 18 1-9/16 3-1/2 1-9/16<br />

JDS24 Max 4 -- -- 10d x 1-1/2 2 10d 1890 1285 8.41 5.72 1340 910 5.96 4.05<br />

JDS26-175 -- -- 18 1-9/16 5-7/16 1-3/4 2 4 10d x 1-1/2 4 10d x 1-1/2 1805 1330 8.03 5.92 1280 945 5.69 4.20<br />

JDS26 Min 2 4 10d x 1-1/2 4 10d x 1-1/2 1805 1330 8.03 5.92 1280 945 5.69 4.20<br />

PFD26 18 1-9/16 5-1/2 1-9/16<br />

JDS26 Max 4 -- -- 10d x 1-1/2 4 10d 2735 1465 12.17 6.52 1940 1040 8.63 4.63<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

red font.<br />

112<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


<strong>EWP</strong> <strong>Hangers</strong><br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>EWP</strong> Hanger Selector Guide<br />

Hanger<br />

Type<br />

Face<br />

Mount<br />

Top<br />

Mount<br />

Glulam<br />

Slope / Skew<br />

<strong>USP</strong><br />

Series<br />

THF<br />

Face Mount<br />

Top Mount<br />

Skewed<br />

Sloped<br />

Formed<br />

Welded<br />

I-Joist<br />

Supported Member<br />

LVL, LSL, PSL<br />

Truss<br />

Supporting Member<br />

Glulam<br />

Dimensional Wood<br />

I-Joist<br />

LVL, LSL, PSL<br />

Truss<br />

Glulam<br />

Masonry<br />

Steel<br />

Gauge<br />

18 3,050 - 5,240 3,050 - 5,240 2,166 - 3,720 -- --<br />

16 3,310 - 6,855 3,310 - 6,855 2,350 - 4,867 -- --<br />

12 5,420 - 6,735 5,420 - 6,735 3,848 - 4,782 -- --<br />

HUS 16 9,025 9,025 6,408 -- --<br />

HD 14 4,545 - 7,215 4,545 - 7,215 3,225 - 5,123 -- --<br />

HDQ-IF 14 5,315 - 8,460 5,315 - 8,460 3,775 - 6,005 -- --<br />

THD<br />

14 11,540 11,540 8,193 -- --<br />

12 12,455 - 13,785 12,455 - 13,785 8,843 - 9,787 -- --<br />

THDH 12 13,190 - 18,810 13,190 - 18,810 9,365 - 13,355 -- --<br />

TFL 18 2,370 2,495 1,771 -- --<br />

THO<br />

18 1,935 - 3,910 1,645 - 4,450 1,170 - 3,160 -- --<br />

16 1,485 - 3,355 1,690 - 4,820 1,200 - 3,425 -- --<br />

12 3,355 - 5,090 6,005 - 9,500 4,265 - 6,745 -- --<br />

TFI 16 3,685 - 4,675 4,190 - 5,315 2,975 - 3,775 -- --<br />

BPH 12 4,415 - 5,300 3,780 - 5,055 2,865 - 4,725 -- --<br />

MPH 12 -- -- -- -- -- -- 3,745 - 6,165<br />

PHM<br />

7 - Top Flange,<br />

10 - Stirrup<br />

5,090 - 5,395 4,125 - 4,880 4,125 - 4,880 -- --<br />

PHXU 7 6,370 - 9,575 6,370 - 7,610 4,420 - 5,170 -- --<br />

HLBH 7 14,725 - 15,295 13,825 12,840 -- --<br />

HGU 7 24,705 - 25,015 24,705 - 25,015 17,540 - 17,760 -- --<br />

KLEG 1 7 15,060 15,060 12,950 -- --<br />

KMEG 1 7 17,555 17,555 15,095 -- --<br />

KEG 1 <br />

Flange,<br />

23,125 - 27,785 23,125 - 27,785 19,890 - 23,895 -- --<br />

KHHB 7 7,035 7,035 5,910 -- --<br />

KGB 7 9,300 9,300 7,810 -- --<br />

KHGB 7 10,845 10,845 9,110 -- --<br />

KGLT<br />

3 - Top Flange,<br />

7 - Stirrup<br />

10,865 10,865 9,125 -- --<br />

KHGLT<br />

3 - Top Flange,<br />

7 - Stirrup<br />

14,615 - 18,420 14,615 - 18,420 12,275 - 15,475 -- --<br />

KGLS<br />

3 - Top Flange,<br />

7 - Stirrup<br />

14,795 - 29,410 14,795 - 29,410 12,430 - 24,705 -- --<br />

KHGLS<br />

3 - Top Flange,<br />

7 - Stirrup<br />

29,785 - 30,220 29,785 - 30,220 25,020 - 25,385 -- --<br />

KGLST<br />

3 - Top Flange,<br />

7 - Stirrup<br />

18,575 - 37,575 18,575 - 37,575 15,605 - 31,565 -- --<br />

KHGLST<br />

3 - Top Flange,<br />

7 - Stirrup<br />

27,720 - 38,280 27,720 - 38,280 23,285 - 32,155 -- --<br />

LGU 10 10,760 10,760 7,640 -- --<br />

MGU 10 17,465 17,465 12,400 -- --<br />

LSSH<br />

Style<br />

18 1,340 - 2,775 1,340 - 2,775 950 - 1,970 -- --<br />

16 2,985 - 5,230 2,985 - 5,230 2,120 - 3,715 -- --<br />

1) KEG, KLEG, KMEG hangers assume factored resistences with top flange.<br />

<br />

New products or updated product information are designated in red font.<br />

LVL<br />

100% Factored Resistance (Lbs.) Range<br />

DF-L<br />

Header Material<br />

SPF<br />

Masonry<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 113<br />

<strong>USP</strong>2240-131


<strong>EWP</strong> <strong>Hangers</strong><br />

<strong>EWP</strong> Installation Guide . . . Pages 116-117<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Face Mount <strong>Hangers</strong> . . . . Pages 118-123<br />

• THF Series<br />

Light capacity face mount hanger for I-Joists.<br />

• HD Series<br />

Medium capacity hanger for LVL, LSL, and PSL beams.<br />

• HDQIF Series<br />

Inverted flange medium capacity hanger for LVL, LSL, and PSL beams.<br />

• HUS Series<br />

Medium capacity hanger for LVL, LSL, and PSL beams with deep seat.<br />

• THD Series<br />

Medium-to-heavy capacity hanger for LVL, LSL, and PSL beams.<br />

• THDH Series<br />

Heavy capacity hanger for LVL, LSL, and PSL beams.<br />

Top Mount <strong>Hangers</strong> . . . . . Pages 124-142<br />

• TFL Series<br />

Light capacity top mount I-Joist hanger.<br />

THF HD HDQIF<br />

HUS<br />

THD<br />

THDH<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

• THO Series<br />

Light-to-medium capacity top mount hanger.<br />

• TFI Series<br />

Medium capacity I-Joist hanger.<br />

• BPH Series<br />

Medium capacity top mount hanger for LVL, LSL, and PSL beams.<br />

TFL<br />

THO<br />

TFI<br />

• HLBH Series<br />

Heavy capacity hanger for LVL, LSL, and PSL beams.<br />

• PHM Series<br />

Medium capacity welded hanger for LVL, LSL, and PSL beams with<br />

7 gauge top flanges.<br />

• PHXU Series<br />

Medium capacity formed hanger for LVL, LSL, and PSL beams with<br />

uplift capacity.<br />

BPH<br />

HLBH<br />

PHM<br />

• MPH Series<br />

Medium capacity masonry hanger for I-Joists, LVL, LSL, and<br />

PSL beams.<br />

PHXU<br />

MPH<br />

114<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


<strong>EWP</strong> <strong>Hangers</strong><br />

Adjustable Rafter-to-Plate<br />

<strong>Connectors</strong>. . . . . . . . . . . . . . . . . . . Page 143<br />

• TMP Series<br />

Adjustable for pitches from 1/12 to 6/12.<br />

• TMPH Series<br />

Adjustable for pitches from 6/12 to 14/12.<br />

TMP<br />

TMPH<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Slope/Skew <strong>Hangers</strong> . . . . . . . . . . Page 144<br />

• LSSH Series<br />

Field adjustable slope and skew hanger.<br />

Glulam <strong>Hangers</strong> . . . . . . . . . Pages 145-150<br />

• HGU, MGU, & LGU Series<br />

Face mount glulam hanger fastens with WS wood screws.<br />

• GHF Series<br />

Face mount glulam hanger fastens with WS wood screws.<br />

• KEG, KLEG, & KMEG Series<br />

Top flange glulam hanger fastens with bolts.<br />

• KGB, KHGB, & KHHB Series<br />

Top flange glulam hanger fastens with WS wood screws.<br />

• KGLT & KHGLT Series<br />

Heavy capacity top flange glulam hanger fastens with WS wood screws.<br />

• KGLS, KGLST, KHGLS, & KHGLST Series<br />

Glulam saddle hanger fastens with WS wood screws.<br />

HGU, LGU, MGU<br />

KHHB<br />

GHF<br />

KGLT<br />

KLEG<br />

KGLS<br />

LSSH<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 115<br />

<strong>USP</strong>2240-131


Wood I-Joist Installation to Wood<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Sloped I-Joists<br />

Use sloped seat hangers and beveled web stiffeners<br />

whenever the slope exceeds the following: 1/2:12 for seat<br />

bearing lengths of 21/2˝ or less; 3/8:12 for bearing lengths<br />

between 21/2˝ and 31/2˝; and 1/4:12 for bearing lengths in<br />

excess of 31/2˝.<br />

Multiple I-Joist Plies<br />

Fasten together multiple plies of wood I-Joists, in<br />

accordance with the manufacturer’s installation guidelines, such<br />

that the joists act as a single unit.<br />

I-Joist Rotation<br />

It may be necessary to install straps, blocking, or sheathing to<br />

restrain torsional rotation of a supporting wood I-Joist when<br />

using top mount I-Joist hangers.<br />

Fasteners<br />

Install only the specified nails. The flanges of wood<br />

I-Joists may split if larger diameter nails or longer nails are<br />

installed. Do not install nails larger than 16d common wire nails<br />

(0.162˝ diameter) into the web stiffeners in the wood I-Joist.<br />

Backer Blocks<br />

Pattern the nails used to install backer blocks or web<br />

stiffeners in wood I-Joists to avoid splitting the block. The nail<br />

pattern should be sufficiently spaced to avoid the same grain<br />

line, particularly with solid sawn backer blocks. Backer blocks<br />

must be installed on wood I-Joist acting as the header, or<br />

supporting member. Install in accordance with the I-Joist<br />

manufacturer’s installation guidelines. The nails used to<br />

install hangers mounted to an I-Joist header must penetrate<br />

through the web and into the backer block on the opposite<br />

side.<br />

Top Flange <strong>Hangers</strong><br />

The thickness of the hanger metal and nail heads on top mount hangers must be evaluated for the effect on<br />

subsequent sheathing. Ensure that the top mount hanger is installed so the flanges of the hanger are not<br />

over-spread which tends to elevate the supported I-Joist causing uneven floor surfaces and squeaking. Similarly, ensure that<br />

the hanger is installed plumb such that the face flanges of the hanger are mounted firmly against the<br />

wide-face surface of the header.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Flush framing ! Hanger over-spread ! Hanger not plumb<br />

Correct Slant Nail Installation<br />

Always secure<br />

wood I-Joist using<br />

10d x 1 1 ⁄ 2˝<br />

nail driven at a<br />

30° to 45° angle<br />

and firmly seated<br />

!<br />

!<br />

Common Nailing Errors<br />

Wrong Angle<br />

When a nail is driven into the bottom flange of the wood<br />

I-Joist parallel to the glue lines, separation of veneers can<br />

occur which substantially reduces the design loads of the<br />

connection.<br />

Nail Too Long<br />

When using nails longer than <strong>USP</strong>’s recommended nails,<br />

bottom flange splitting may occur. Also, this can raise the<br />

wood I-Joist off the seat, resulting in uneven surfaces and<br />

squeaky floors along with reduced factored resistance.<br />

116<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Support Height & Lateral Stability<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>Hangers</strong> for joists without web stiffeners must support the<br />

I-Joist’s top flange and provide lateral resistance with no<br />

more than 1⁄8˝ horizontal deflection.<br />

1/8˝ (3.175 mm)<br />

maximum gap<br />

Nailer Installations<br />

Resist lateral movement<br />

Web stiffener<br />

Correct Hanger Attachment to Nailer<br />

A nailer or sill plate is considered to be any wood member attached to a steel beam,<br />

concrete block wall, concrete stem wall, or other structure unsuitable for nailing, which<br />

is used as a nailing surface for top mount hangers to hold beams or joists.<br />

Nailer Sized Correctly<br />

Top flange of hanger is fully supported and recommended nails have full<br />

penetration into nailer, resulting in a carried member hanging safely at the proper<br />

height.<br />

The nailer must be sized to fit the support width as shown and be of sufficient thickness<br />

to satisfy recommended top flange nailing requirements. A design professional must<br />

specify nailer attachment to steel beams.<br />

<strong>Hangers</strong> for joists with web stiffeners must support a<br />

minimum of 60% of joist depth or potential joist rotation must<br />

be addressed.<br />

(Top flange support requirements can be verified in this sections charts under the Web Stiffener Reqd. column.)<br />

1/4˝<br />

(6.35<br />

mm)<br />

Max.<br />

Avoid direct contact between<br />

hangers and steel beams, which<br />

may cause squeaks<br />

Joist<br />

depth<br />

60% min. of<br />

joist depth<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Wrong Nailer Size Causes Component Failure<br />

1/4˝ ( 6.35mm) Max.<br />

! Too Narrow<br />

! Too Wide<br />

! Too Thin<br />

Top flange not fully supported can Loading can cause cross grain Top flange nailing cannot fully<br />

cause nail breakout. Or, by fully breaking of nailer. The penetrate nailer, causing reduced<br />

supporting top flange, hanger is<br />

tilted back, causing lifting of carried<br />

member which results in uneven<br />

surfaces and squeaky floors.<br />

recommended nailer overhang<br />

is 1⁄4˝ maximum per side.<br />

factored resistance. Never use<br />

hangers which require multiple face<br />

nails since the factored resistance<br />

are dependent on all nail holes being<br />

used.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 117<br />

<strong>USP</strong>2240-131


Face Mount <strong>Hangers</strong> – THF series<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Designed to provide lateral support for the top chords of I-Joists<br />

in depths up to 16˝. Eliminates the need for web stiffeners in<br />

most applications (see Web Stiffener Reqd. column in <strong>EWP</strong><br />

Face Mount Hanger Chart for specific applications).<br />

Materials: See <strong>EWP</strong> Face Mount <strong>Hangers</strong> charts,<br />

pages 121-122.<br />

Finish: G90 galvanizing<br />

Options: See Specialty Options chart.<br />

Codes: Load values are derived from data submitted<br />

to various North American building code<br />

evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Install 10d x 1 1 ⁄ 2˝ nails into joist through raised dimple at<br />

a 30° to 45° angle.<br />

• THF Min – Fill all round nail holes.<br />

• THF Max – Fill all round and diamond holes.<br />

Specialty Options Chart – refer to Specialty<br />

Options pages 210 to 211 for additional details.<br />

Typical THF I-Joist<br />

to Joist installation<br />

H<br />

W<br />

2˝<br />

Additional diamond<br />

nail holes for<br />

maximum nailing<br />

Standard round<br />

nail holes for<br />

minimum nailing<br />

THF single<br />

Option Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Inverted Flange<br />

<br />

Not available in<br />

Range <br />

<br />

See Sloped Seat and Skewed<br />

<br />

<br />

Factored<br />

Resistance<br />

Ordering<br />

100% of table load.<br />

<br />

<br />

Add SK, angle required,<br />

and right (R) or left (L),<br />

to product number.<br />

Example: THF23925-SK45R<br />

100% of table load<br />

Add SL, slope required,<br />

and up (U) or down (D),<br />

to product number.<br />

Example: THF23925-SL30D<br />

1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange.<br />

2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails.<br />

3) All sloped, skewed, or combinations require bevel cut on joist in all applications.<br />

4) Modifications to THF hangers do not feature seat cleats.<br />

80% of table load.<br />

<br />

<br />

See Sloped Seat and Skewed<br />

Example:<br />

THF23925-SK45RSL30D<br />

100% of table load.<br />

<br />

nailing into the support<br />

members end grain.<br />

Add IF,<br />

to product number.<br />

Example: THF23925IF<br />

Dimple allows<br />

30˚ to 45˚<br />

nailing<br />

Typical THF double I-Joist<br />

to LVL installation<br />

Raised Dimple<br />

nail holes allow<br />

30° to 45°<br />

nailing into<br />

I-Joist bottom<br />

flange.<br />

W<br />

D<br />

H<br />

THF double<br />

Seat Cleat®<br />

helps lock<br />

I-Joist into place<br />

for<br />

positive seating<br />

and nailing ease.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Face Mount <strong>Hangers</strong> – HD series<br />

Designed to to support LVL, LSL, and PSL beams and headers in medium load conditions.<br />

Materials: See <strong>EWP</strong> Face Mount <strong>Hangers</strong> charts, pages 122-123.<br />

Finish: G90 galvanizing<br />

Options: See Specialty Options chart.<br />

Codes: Load values are derived from data submitted<br />

to various North American building code<br />

evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Drive bend line nails into header at 45° to achieve listed loads<br />

Drive bend line nails<br />

into header at 45° to<br />

achieve listed loads.<br />

Typical HD<br />

bend line nail installation<br />

Specialty Options Chart – refer to Specialty Options pages 210 to 211 for additional details.<br />

Typical HD<br />

installation<br />

118<br />

Option Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Inverted Flange<br />

<br />

See Sloped Seat and Not available in<br />

Range <br />

Skewed <br />

<br />

Factored<br />

Resistance<br />

Ordering<br />

100% of table load.<br />

75% of uplift load on<br />

<br />

Add SK, angle required,<br />

and right (R) or left (L),<br />

to product number.<br />

Example: HD410-SK45R<br />

100% of table load<br />

Add SL, slope required,<br />

and up (U) or down (D),<br />

to product number.<br />

Example: HD410-SL30D<br />

80% of table load.<br />

75% of uplift load on<br />

<br />

See Sloped Seat and<br />

Skewed<br />

Example:<br />

HD410-SK45RSL30D<br />

100% of table load.<br />

65% of table load when<br />

nailing into the support<br />

members end grain.<br />

Add IF,<br />

to product number.<br />

Example: HD410IF<br />

1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange.<br />

2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails.<br />

3) All sloped, skewed, or combinations require bevel cut on joist in all applications and web stiffeners with I-joists.<br />

<strong>Hangers</strong> for square-cut joists are available as a Custom. Further reductions in allowable loads may apply.<br />

4) Modifications of HD hangers may be manufactured as hot rolled, welded, or primed.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

Bend line<br />

nailing<br />

W<br />

HD<br />

H<br />

D


Face Mount <strong>Hangers</strong> – HDQIF series<br />

HDQIF hangers are heavy capacity face mount hangers<br />

that can be used to support LVL, LSL and PSL beams and<br />

headers.<br />

Materials: 14 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

H<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• WS15 and WS3 Wood Screws are supplied with<br />

HDQIF hangers.<br />

Face Mount <strong>Hangers</strong> – HUS series<br />

Up to 3/4˝<br />

gap<br />

Typical HDQIF<br />

installation<br />

W<br />

HDQIF<br />

3˝<br />

Designed for medium load conditions. Extended 3˝ deep seat provides extra truss bearing.<br />

Materials: 16 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Joist nails must be driven at a 30° to 45° angle through<br />

the joist into the header to achieve listed loads.<br />

Drive joist nails into<br />

header at 30° to 45° to<br />

achieve listed loads.<br />

Typical HUS<br />

installation<br />

2˝<br />

H<br />

Dimple allows<br />

30˚ to 45˚<br />

nailing<br />

Typical HUS<br />

double shear installation<br />

W<br />

HUS<br />

3˝<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 119<br />

<strong>USP</strong>2240-131


Face Mount <strong>Hangers</strong> – THD & THDH series<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

THD – Medium capacity hanger for LVL, LSL, and PSL beams.<br />

THDH – Heavy capacity hanger for LVL, LSL, and PSL beams.<br />

Materials: See <strong>EWP</strong> Face Mount <strong>Hangers</strong> charts, pages 123.<br />

Finish: G90 galvanizing<br />

Options: THDH412 is available in Triple Zinc. To order, add TZ to stock number, as<br />

in THDH412-TZ.<br />

Rough/Full sizes available for THD series. THD hangers with widths<br />

greater than 3˝ can have one flange inverted with no load<br />

reduction. Specify left (L) or right (R) flange. See Specialty Options chart.<br />

Codes: Load values are derived from data submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• THD – Drive bend line nails into header at 45° to achieve listed loads.<br />

• THDH – Drive joist nails into header at 30° to 45° to achieve listed loads.<br />

Typical THDH<br />

double shear installation<br />

Drive joist nails into<br />

header at 30° to 45° to<br />

achieve listed loads.<br />

Drive bend line nails<br />

into header at 45° to<br />

achieve listed loads.<br />

Typical THD<br />

bend line nail installation<br />

Some model<br />

designs may<br />

vary from<br />

illustration<br />

shown<br />

Typical THD<br />

installation<br />

D<br />

H<br />

W<br />

THD single<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Left<br />

flange<br />

3˝<br />

Specialty Options Chart – refer to Specialty Options pages 210 to 211 for additional details.<br />

Option <strong>USP</strong> Series Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3,4 Inverted Flange<br />

<br />

Range<br />

THD<br />

<br />

<br />

<br />

THDH N/A<br />

<br />

<br />

THD <br />

Factored<br />

<br />

Resistance<br />

<br />

THDH<br />

<br />

<br />

<br />

<br />

<br />

N/A<br />

Ordering<br />

THD<br />

THDH<br />

<br />

(R) (L),<br />

<br />

<br />

<br />

(U) (D),<br />

<br />

<br />

<br />

<br />

<br />

1IF, <br />

(R) (L),<br />

<br />

N/A<br />

<br />

<br />

<br />

<br />

W D Right<br />

flange<br />

THD double<br />

or larger<br />

W<br />

Dimple allows<br />

30˚ to 45˚<br />

nailing<br />

2 1 /2˝<br />

D<br />

H<br />

H<br />

THDH26-2<br />

120<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


<strong>EWP</strong> Face Mount Hanger – I-Joist Charts<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Dimensions (in)<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

<strong>USP</strong><br />

Joist Size StockNo. Ref. No. W H D Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

1-1/2 x 9 -1/4 - 9-1/2<br />

IUS1.56/9.5,<br />

THF15925 Min<br />

8 10d 2 10dx1-1/2 3050 525 13.57 2.34 2166 373 9.63 1.66<br />

LF159<br />

-- 18 1-1/2 9-1/16 2<br />

IUT29,<br />

THF15925 Max<br />

12 10d 2 10dx1-1/2 3225 525 14.35 2.34 2290 373 10.19 1.66<br />

MIU1.56/9<br />

IUS1.56/11.88,<br />

THF15112 Min<br />

LF1511<br />

1-1/2 x 11-1/4 - 11-7/8 -- 18 1-1/2 11-1/16 2<br />

8 10d 2 10dx1-1/2 3050 525 13.57 2.34 2166 373 9.63 1.66<br />

THF15112 Max<br />

IUT211,<br />

MIU1.56/11<br />

16 10d 2 10dx1-1/2 4135 525 18.39 2.34 2936 373 13.06 1.66<br />

1-1/2 x 14<br />

THF15140 Min LF1514<br />

-- 18 1-1/2 13-1/2 2<br />

12 10d 2 10dx1-1/2 3815 525 16.97 2.34 2709 373 12.05 1.66<br />

THF15140 Max IUT214 20 10d 2 10dx1-1/2 4045 525 17.99 2.34 2872 373 12.78 1.66<br />

1-5/8 x 9-1/4 - 9-1/2<br />

THF16925 Min -- --<br />

-- 18 1-5/8 9 2<br />

8 10d 2 10d x 1-1/2 3050 525 13.57 2.34 2166 375 9.63 1.67<br />

THF16925 Max IUT1.68/9 12 10d 2 10d x 1-1/2 3225 525 14.35 2.34 2290 375 10.19 1.67<br />

1-5/8 x 11-1/4 - 12<br />

THF16112 Min -- --<br />

-- 18 1-5/8 11 2<br />

8 10d 2 10d x 1-1/2 3050 525 13.57 2.34 2166 375 9.63 1.67<br />

THF16112 Max IUT1.68/11 16 10d 2 10d x 1-1/2 4135 525 18.39 2.34 2936 375 13.06 1.67<br />

1-5/8 x 14<br />

THF16140 Min -- --<br />

-- 18 1-5/8 13-7/16 2<br />

12 10d 2 10d x 1-1/2 3815 525 16.97 2.34 2709 375 12.05 1.67<br />

THF16140 Max IUT1.68/14 20 10d 2 10d x 1-1/2 4045 525 17.99 2.34 2872 375 12.78 1.67<br />

1-3/4 x 9-1/4 - 9-1/2<br />

THF17925 Min<br />

IUS1.81/9.5,<br />

LF179<br />

-- 18 1-3/4 8-15/16 2<br />

8 10d 2 10dx1-1/2 3050 525 13.57 2.34 2166 373 9.63 1.66<br />

THF17925 Max IUT9 12 10d 2 10dx1-1/2 3225 525 14.35 2.34 2290 373 10.19 1.66<br />

IUS1.81/11.88,<br />

THF17112 Min<br />

1-3/4 x 11-1/4 - 11-7/8 LF1711 -- 18 1-3/4 10-15/16 2<br />

8 10d 2 10dx1-1/2 3050 525 13.57 2.34 2166 373 9.63 1.66<br />

THF17112 Max IUT11 16 10d 2 10dx1-1/2 4135 525 18.39 2.34 2936 373 13.06 1.66<br />

1-3/4 x 14<br />

THF17140 Min<br />

IUS1.81/14,<br />

LF1714 -- 18 1-3/4 13-3/8 2<br />

12 10d 2 10dx1-1/2 3815 525 16.97 2.34 2709 373 12.05 1.66<br />

THF17140 Max IUT14 20 10d 2 10dx1-1/2 4045 525 17.99 2.34 2872 373 12.78 1.66<br />

1-3/4 x 16 THF17157 IUS1.81/16 -- 18 1-13/16 15-3/4 3-1/2 24 10d 2 10dx1-1/2 4435 525 19.73 2.34 3149 373 14.01 1.66<br />

2 - 2-1/8<br />

IUS2.06/9.5,<br />

THF20925 Min<br />

8 10d 2 10dx1-1/2 3050 525 13.57 2.34 2166 373 9.63 1.66<br />

LF209<br />

-- 18 2-1/8 8-7/8 2<br />

x 9-1/4 - 9-1/2<br />

THF20925 Max IUT2.06/9 12 10d 2 10dx1-1/2 3225 525 14.35 2.34 2290 373 10.19 1.66<br />

2 - 2-1/8<br />

IUS2.06/11.88,<br />

THF20112 Min<br />

8 10d 2 10dx1-1/2 3050 525 13.57 2.34 2166 373 9.63 1.66<br />

LF2011 -- 18 2-1/8 11-3/16 2<br />

x 11-1/4 - 11-7/8<br />

THF20112 Max IUT2.06/11 16 10d 2 10dx1-1/2 4135 525 18.39 2.34 2936 373 13.06 1.66<br />

2 - 2-1/8 x 14<br />

THF20140 Min<br />

IUS2.06/14,<br />

LF2014 -- 18 2-1/8 13-1/4 2<br />

12 10d 2 10dx1-1/2 3815 525 16.97 2.34 2709 373 12.05 1.66<br />

THF20140 Max IUT2.06/14 20 10d 2 10dx1-1/2 4045 525 17.99 2.34 2872 373 12.78 1.66<br />

2 - 2-1/8 x 16 THF20157<br />

IUS2.06/16,<br />

IUT2.06/16<br />

-- 18 2-1/8 15-3/4 3-3/8 24 10d 2 10dx1-1/2 4435 525 19.73 2.34 3149 373 14.01 1.66<br />

LF239,<br />

HU359,<br />

2-1/4 - 2-5/16<br />

IUS2.37/9.5,<br />

THF23925<br />

x 9-1/4 - 9-1/2<br />

IUT3510,<br />

MIU2.37/9,<br />

U3510/14<br />

-- 18 2-5/16 9-3/16 2-1/2 12 10d 2 10dx1-1/2 3310 335 14.72 1.49 2350 238 10.45 1.06<br />

2-1/4 - 2-5/16<br />

x 11-1/4 - 11-7/8<br />

THF23118<br />

2-1/4 - 2-5/16 x 14 THF23140<br />

2-1/4 - 2-5/16 x 16 THF23160<br />

2-1/4 - 2-5/16 x 18 - 28 THF23180<br />

2-1/2 x 9-1/4 - 9-1/2 THF25925<br />

2-1/2 x 11-1/4 - 11-7/8 THF25112<br />

LF2311,<br />

HU3511,<br />

IUS2.37/11.88,<br />

IUT3512,<br />

MIU2.37/11<br />

LF2314,<br />

HU3514,<br />

IUS2.37/14,<br />

IUT3514,<br />

MIU2.37/14<br />

HU3516/22,<br />

IUS2.37/16,<br />

IUT3516,<br />

MIU2.37/16<br />

HU3524/30,<br />

MIU2.37/18,<br />

MIU2.37/20<br />

LF259,<br />

IUS2.56/9.5,<br />

IUT310,<br />

MIU2.56/9<br />

LF2511,<br />

IUS2.56/11.88,<br />

IUT312,<br />

MIU2.56/11<br />

Web Stiffener Reqd.<br />

Steel Gauge<br />

Fastener Schedule 2,3<br />

Header Joist<br />

DF-L Header (Lbs)<br />

-- 18 2-5/16 11-3/16 2-1/2 14 10d 2 10dx1-1/2 3310 720 14.72 3.20 2350 511 10.45 2.27<br />

-- 16 2-5/16 13-1/2 2-1/2 18 10d 2 10dx1-1/2 4405 720 19.60 3.20 3128 511 13.91 2.27<br />

-- 16 2-5/16 15-9/16 2-1/2 22 10d 2 10dx1-1/2 4405 720 19.60 3.20 3128 511 13.91 2.27<br />

x 16 2-5/16 17-1/8 2-1/2 24 10d 8 10dx1-1/2 6235 2435 27.74 10.83 4427 1729 19.69 7.69<br />

-- 18 2-1/2 9-1/8 2-1/2 12 10d 2 10dx1-1/2 3310 335 14.72 1.49 2350 238 10.45 1.06<br />

-- 18 2-1/2 11-1/8 2-1/2 14 10d 2 10dx1-1/2 3310 720 14.72 3.20 2350 511 10.45 2.27<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

DF-L Header (kN)<br />

Factored Resistance<br />

S-P-F Header (Lbs)<br />

S-P-F Header (kN)<br />

H<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

W<br />

D<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 121<br />

<strong>USP</strong>2240-131


<strong>EWP</strong> Face Mount Hanger – I-Joist Charts continued<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Web Stiffener Reqd.<br />

Steel Gauge<br />

Dimensions (in)<br />

Fastener Schedule 2,3<br />

Header Joist<br />

DF-L Header (Lbs)<br />

Factored Resistance<br />

DF-L Header (kN) S-P-F Header (Lbs)<br />

S-P-F Header (kN)<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

<strong>USP</strong><br />

Joist Size StockNo. Ref. No. W H D Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

2-1/2 x 13 THF25130 IUT313 -- 16 2-1/2 12-1/4 2-1/2 18 10d 2 10dx1-1/2 3310 720 14.72 3.20 2350 511 10.45 2.27<br />

2-1/2 x 14 THF25140<br />

LF2514,<br />

IUS2.56/14,<br />

IUT314,<br />

-- 16 2-1/2 13-7/16 2-1/2 18 10d 2 10dx1-1/2 4405 720 19.60 3.20 3128 511 13.91 2.27<br />

MIU2.56/14<br />

2-1/2 x 16 THF25160<br />

IUS2.56/16,<br />

IUT316,<br />

MIU2.56/16, -- 16 2-1/2 15-1/2 2-1/2 22 10d 2 10dx1-1/2 4405 720 19.60 3.20 3128 511 13.91 2.27<br />

MIU2.56/18,<br />

MIU2.56/20<br />

2-1/2 x 18 - 24 THF25160<br />

IUS2.56/16,<br />

IUT316,<br />

MIU2.56/16, x 16 2-1/2 15-1/2 2-1/2 22 10d 2 10dx1-1/2 4405 720 19.60 3.20 3128 511 13.91 2.27<br />

MIU2.56/18,<br />

MIU2.56/20<br />

2-5/8 x 9-1/4 - 9-1/2 THF26925 IUT2.68/10 -- 18 2-5/8 9-1/16 2-1/2 12 10d 2 10dx1-1/2 3310 2300 14.72 10.23 2350 1633 10.45 7.26<br />

2-5/8 x 11-1/4 - 11-7/8 THF26112 IUT2.68/12 -- 18 2-5/8 11-1/16 2-1/2 14 10d 2 10dx1-1/2 3310 720 14.72 3.20 2350 511 10.45 2.27<br />

2-5/8 x 14 THF26140 -- -- -- 16 2-5/8 13-3/8 2-1/2 18 10d 2 10dx1-1/2 4405 720 19.60 3.20 3128 511 13.91 2.27<br />

2-5/8 x 16 THF26160 -- -- -- 16 2-5/8 15-7/16 2-1/2 22 10d 2 10dx1-1/2 4405 720 19.60 3.20 3128 511 13.91 2.27<br />

3 x 9-1/4 - 14 THF15925-2 MIU3.12/9 x 16 3-1/8 9-3/16 2-1/2 12 10d 6 10d 5180 3325 23.04 14.79 3678 2361 16.36 10.50<br />

3 x 11-1/4 - 14 THF15112-2 MIU3.12/11 x 16 3-1/8 10-13/16 2-1/2 14 10d 6 10d 5420 3325 24.11 14.79 3848 2361 17.12 10.50<br />

3 x 14 THF15140-2 -- -- x 12 3-1/8 12-3/4 2-1/2 18 10d 6 10d 5420 3325 24.11 14.79 3848 2360 17.12 10.50<br />

3-1/4 x 9-1/4 - 14 THF16925-2 -- -- x 16 3-3/8 9-1/16 2-1/2 12 10d 6 10d 5180 3325 23.04 14.79 3678 2360 16.36 10.50<br />

3-1/4 x 11-1/4 - 14 THF16112-2 HU3.31/11 x 16 3-3/8 10-3/4 2-1/2 14 10d 6 10d 5420 3325 24.11 14.79 3848 2360 17.12 10.50<br />

3-1/4 x 14 THF16140-2 -- -- x 12 3-3/8 12-5/8 2-1/2 18 10d 6 10d 5420 3325 24.11 14.79 3848 2360 17.12 10.50<br />

3-1/2 x 9-1/4 - 14 THF35925<br />

LF359,<br />

IUS3.56/9.5, -- 18 3-1/2 8-5/8 2-1/2 12 10d 2 10dx1-1/2 5240 465 23.31 2.07 3720 330 16.55 1.47<br />

IUT410<br />

3-1/2 x 11-7/8 - 16 THF35112<br />

LF3511,<br />

IUS3.56/11.88, -- 18 3-1/2 11-1/8 2-1/2 16 10d 2 10dx1-1/2 5240 465 23.31 2.07 3720 330 16.55 1.47<br />

IUT412<br />

3-1/2 x 14 - 20 THF35140<br />

LF3514,<br />

IUS3.56/14, -- 16 3-1/2 12-15/16 2-1/2 20 10d 2 10dx1-1/2 6680 465 29.72 2.07 4743 330 21.10 1.47<br />

IUT414<br />

3-1/2 x 16 - 22 THF17157-2 -- -- x 12 3-5/8 15-3/4 2-1/2 22 10d 6 10d 6735 3325 29.96 14.79 4782 2360 21.27 10.50<br />

3-1/2 x 16 - 22 THF35157<br />

IUS3.56/16,<br />

IUT416<br />

-- 16 3-1/2 15 2-1/2 22 10d 2 10dx1-1/2 6680 465 29.72 2.07 4743 330 21.10 1.47<br />

3-1/2 x 18 - 26 THF35165 -- -- x 16 3-1/2 16-9/16 2-1/2 24 10d 8 10dx1-1/2 6680 2435 29.72 10.83 4743 1729 21.10 7.69<br />

4 - 4-3/16 x 9-1/4 - 9-1/2 THF20925-2<br />

HU4.12/9,<br />

HU4.28/9,<br />

HU4.75/9, -- 16 4-3/16 8-11/16 2-1/2 12 10d 6 10d 5255 3325 23.38 14.79 3731 2361 16.60 10.50<br />

MIU4.12/9,<br />

MIU4.28/9<br />

HU4.12/11,<br />

HU4.28/11,<br />

4 - 4-3/16<br />

THF20112-2 HU4.75/11,<br />

x 11-1/4 - 11-7/8<br />

MIU4.12/11,<br />

-- 16 4-3/16 11 2-1/2 16 10d 6 10d 6855 3325 30.49 14.79 4867 2361 21.65 10.50<br />

MIU4.28/11<br />

MIU4.12/14,<br />

4 - 4-3/16 x 14 THF20140-2<br />

MIU4.12/16,<br />

MIU4.28/14,<br />

-- 16 4-3/16 13-5/8 2-1/2 20 10d 6 10d 6735 3325 29.96 14.79 4782 2360 21.27 10.50<br />

MIU4.28/16<br />

4-1/2 - 4-5/8<br />

x 9-1/4 - 14<br />

THF23925-2 -- -- x 16 4-3/4 8-3/8 2-1/2 14 10d 6 10d 5240 3325 23.31 14.79 3720 2361 16.55 10.50<br />

4-1/2 - 4-5/8<br />

x 11-1/4 - 16<br />

THF23118-2 -- -- x 16 4-3/4 10-11/16 2-1/2 16 10d 6 10d 6855 3325 30.49 14.79 4867 2361 21.65 10.50<br />

4-1/2 - 4-5/8 x 14 - 22 THF23140-2<br />

HU3514-2,<br />

MIU4.75/14<br />

x 12 4-3/4 13-5/16 2-1/2 20 10d 6 10d 6680 3325 29.72 14.79 4743 2361 21.10 10.50<br />

4-1/2 - 4-5/8 x 16 - 26 THF23160-2<br />

HU3516-2,<br />

HU3520-2,<br />

MIU4.75/16, x 12 4-3/4 15-15/16 2-1/2 24 10d 6 10d 6680 3325 29.72 14.79 4743 2361 21.10 10.50<br />

MIU4.75/18,<br />

MIU4.75/20<br />

5 x 9-1/4 - 12 THF25925-2 MIU5.12/9 x 16 5-1/8 8-3/16 2-1/2 12 10d 6 10d 5240 3325 23.31 14.79 3720 2361 16.55 10.50<br />

5 x 11-1/4 - 16 THF25112-2 MIU5.12/11 x 16 5-1/8 10-7/16 2-1/2 16 10d 6 10d 5240 3325 23.31 14.79 3720 2361 16.55 10.50<br />

5 x 14 - 20 THF25140-2<br />

HU314-2,<br />

MIU5.12/14<br />

x 12 5-1/8 13-1/8 2-1/2 20 10d 6 10d 6680 3325 29.72 14.79 4743 2361 21.10 10.50<br />

5 x 16 - 26 THF25160-2<br />

HU5.125/16,<br />

MIU5.12/16,<br />

MIU5.12/18,<br />

x 12 5-1/8 15-3/4 2-1/2 24 10d 6 10d 6680 3325 29.72 14.79 4743 2361 21.10 10.50<br />

MIU5.12/20<br />

7 x 9-1/4 - 14 HD7100 HU410-2 x 14 7-1/8 9 2-1/2 12 16d 6 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

7 x 11-1/4 - 16 HD7120 HU412-2 x 14 7-1/8 10-5/8 2-1/2 16 16d 6 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

7 x 14 - 20 HD7140 HU414-2 x 14 7-1/8 13-1/8 2-1/2 20 16d 8 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

H<br />

122<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

W<br />

D


<strong>EWP</strong> Face Mount Hanger – SCL Charts<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Web Stiffener Reqd.<br />

Steel Gauge<br />

Dimensions (in)<br />

Fastener Schedule 2,3,4<br />

Factored Resistance<br />

Header Joist DF-L Header (Lbs) DF-L Header (kN) S-P-F Header (Lbs) S-P-F Header (kN)<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

<strong>USP</strong><br />

Joist Size StockNo. Ref. No. W H D Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

1-3/4 x 7-1/4 HD1770 HU7 x 14 1-13/16 7-1/8 2 14 16d 4 10d x 1-1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

HD17925<br />

HU9,<br />

MIU1.81/9<br />

x 14 1-13/16 9-1/8 2 18 16d 6 10d x 1-1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

1-3/4 x 9-1/4 - 9-1/2 HD17925IF -- -- x 14 1-13/16 9-1/8 2 18 16d 6 10d x 1-1/2 7215 2005 32.10 8.92 5123 1424 22.79 6.33<br />

HDQ179IF HUCQ1.81/9-SDS 14 1-13/16 9 3 8 WS3 4 WS15 5315 3025 23.64 13.46 3775 2150 16.79 9.56<br />

HUS179 HUS1.81/10 x 16 1-13/16 9-1/8 3 30 16d 10 16d 9025 6035 40.15 26.85 6408 4285 28.50 19.06<br />

HD17112<br />

HU11,<br />

MIU1.81/11<br />

x 14 1-13/16 11-3/8 2 22 16d 6 10d x 1-1/2 5915 2005 26.31 8.92 4200 1424 18.68 6.33<br />

1-3/4 x 11-1/4 - 11-7/8 HD17112IF -- -- x 14 1-13/16 11-3/8 2 22 16d 6 10d x 1-1/2 5915 2005 26.31 8.92 4200 1424 18.68 6.33<br />

HDQ17112IF HUCQ1.81/11-SDS 14 1-13/16 11 3 10 WS3 6 WS15 5470 2975 24.33 13.23 3885 2110 17.28 9.39<br />

HUS179 HUS1.81/10 x 16 1-13/16 9-1/8 3 30 16d 10 16d 9025 6035 40.15 26.85 6408 4285 28.50 19.06<br />

HD1714<br />

HU14,<br />

MIU1.81/14,<br />

MIU1.81/16, x 14 1-13/16 13-5/16 2 26 16d 8 10d x 1-1/2 5915 2005 26.31 8.92 4200 1424 18.68 6.33<br />

1-3/4 x 14<br />

MIU1.81/18,<br />

U14<br />

HD1714IF -- -- x 14 1-13/16 13-5/16 2 26 16d 8 10d x 1-1/2 5915 2005 26.31 8.92 4200 1424 18.68 6.33<br />

HDQ1714IF -- -- 14 1-13/16 13-3/8 3 12 WS3 6 WS15 5470 2975 24.33 13.23 3885 2110 17.28 9.39<br />

HUS179 HUS1.81/10 x 16 1-13/16 9-1/8 3 30 16d 10 16d 9025 6035 40.15 26.85 6408 4285 28.50 19.06<br />

HD1714<br />

HU14,<br />

MIU1.81/14,<br />

MIU1.81/16, x 14 1-13/16 13-5/16 2 26 16d 8 10d x 1-1/2 5915 2005 26.31 8.92 4200 1424 18.68 6.33<br />

1-3/4 x 16<br />

MIU1.81/18,<br />

U14<br />

HDQ1714IF -- -- 14 1-13/16 13-3/8 3 12 WS3 6 WS15 5470 2975 24.33 13.23 3885 2110 17.28 9.39<br />

HUS179 HUS1.81/10 x 16 1-13/16 9-1/8 3 30 16d 10 16d 9025 6035 40.15 26.85 6408 4285 28.50 19.06<br />

2-11/16 x 9-1/4 - 14<br />

2-11/16 x 11-1/4 - 16<br />

2-11/16 x 14 - 16<br />

HD27925<br />

HD27112<br />

HD2714<br />

HU2.75/10<br />

HU2.75/12<br />

HU2.75/14<br />

x<br />

x<br />

x<br />

14<br />

14<br />

14<br />

2-3/4<br />

2-3/4<br />

2-3/4<br />

8-5/8<br />

10-7/8<br />

12-7/8<br />

2<br />

2<br />

2<br />

18<br />

22<br />

26<br />

16d<br />

16d<br />

16d<br />

6<br />

6<br />

8<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

4545<br />

5915<br />

5915<br />

2005<br />

2005<br />

2005<br />

20.22<br />

26.31<br />

26.31<br />

8.92<br />

8.92<br />

8.92<br />

3225<br />

4200<br />

4200<br />

1425<br />

1425<br />

1425<br />

14.35<br />

18.68<br />

18.68<br />

6.34<br />

6.34<br />

6.34<br />

THDH27925<br />

THDH27112<br />

THDH2714<br />

-- --<br />

-- --<br />

-- --<br />

x<br />

x<br />

x<br />

12<br />

12<br />

12<br />

2-3/4<br />

2-3/4<br />

2-3/4<br />

9-1/8<br />

10-7/8<br />

12-1/4<br />

4<br />

4<br />

4<br />

46<br />

56<br />

66<br />

16d<br />

16d<br />

16d<br />

12<br />

14<br />

16<br />

16d<br />

16d<br />

16d<br />

13525<br />

16130<br />

16130<br />

6575<br />

9845<br />

11335<br />

60.16<br />

71.75<br />

71.75<br />

29.25<br />

43.79<br />

50.42<br />

9605<br />

11450<br />

11450<br />

4670<br />

6990<br />

8050<br />

42.73<br />

50.93<br />

50.93<br />

20.77<br />

31.09<br />

35.81<br />

HD410<br />

HU410,<br />

MIU3.56/9<br />

x 14 3-9/16 8-13/16 2-1/2 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

3-1/2 x 9-1/4 - 14 HDQ410IF HUCQ410-SDS 14 3-9/16 9 3 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

THD410 HHUS410 x 14 3-5/8 9-1/16 3 38 16d 20 10d 11540 7250 51.33 32.25 8193 5148 36.45 22.90<br />

THDH410 HGUS410 x 12 3-4/7 9-1/8 4 46 16d 12 16d 14760 7480 65.66 33.27 10480 5310 46.62 23.62<br />

HD412<br />

HU412,<br />

MIU3.56/11<br />

x 14 3-9/16 10-13/16 2-1/2 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

3-1/2 x 11-1/4 - 16 HDQ412IF HUCQ412-SDS 14 3-9/16 11 3 14 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

THD412 -- -- x 14 3-5/8 11 3 48 16d 20 10d 11540 7250 51.33 32.25 8193 5148 36.45 22.90<br />

THDH412 HGUS412 x 12 3-4/7 10-1/2 4 56 16d 14 16d 16130 9845 71.75 43.79 11450 6989.95 50.93 31.09<br />

HU414,<br />

HD414<br />

x 14 3-9/16 12-13/16 2-1/2 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

MIU3.56/14<br />

3-1/2 x 14 - 20<br />

THD414 -- -- x 14 3-5/8 12-7/8 3 58 16d 20 10d 11540 7250 51.33 32.25 8193 5148 36.45 22.90<br />

THDH414 HGUS414 x 12 3-4/7 12-1/4 4 66 16d 16 16d 16130 11335 71.75 50.42 11450 8050 50.93 35.81<br />

3-1/2 x 16 - 22 HD416<br />

HU416,<br />

MIU3.56/16<br />

x 14 3-9/16 14-13/16 2-1/2 26 16d 12 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

3-1/2 x 18 - 26 HD418<br />

MIU3.56/18,<br />

MIU3.56/20<br />

x 14 3-9/16 16-1/2 2-1/2 28 16d 8 10d 7215 2685 32.10 11.94 5123 1906 22.79 8.48<br />

HD5210 HU5.31/9 x 14 5-3/8 7-7/8 2-1/2 18 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ5210IF HUCQ5.25/9-SDS 14 5-1/4 9 3 12 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

5-1/4 x 9-1/4 - 11-7/8 THD610 HHUS5.50/10 x 12 5-1/2 9 3 38 16d 20 10d 12455 6425 55.40 28.58 8843 4562 39.34 20.29<br />

THDH610<br />

HGUS5.25/10,<br />

HGUS5.50/10<br />

x 12 5-1/2 9 4 46 16d 16 16d 13190 7030 58.67 31.27 9365 4990 41.66 22.20<br />

HD5212 HU5.31/11 x 14 5-3/8 9-7/8 2-1/2 22 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

HDQ5212IF HUCQ5.25/11-SDS 14 5-1/4 11 3 14 WS3 6 WS3 8460 4970 37.63 22.11 6005 3530 26.71 15.70<br />

5-1/4 x 11-1/4 - 16 THD612 -- -- x 12 5-1/2 11 3 48 16d 20 10d 13785 9850 61.32 43.82 9787 6994 43.54 31.11<br />

THDH612<br />

HGUS5.25/12,<br />

HGUS5.50/12<br />

x 12 5-1/2 11 4 56 16d 20 16d 15465 9105 68.79 40.50 10980 6465 48.84 28.76<br />

HD5214 HU5.31/14 x 14 5-3/8 11-7/8 2-1/2 24 16d 10 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

5-1/4 x 14 - 20<br />

THD614 -- -- 12 5-1/2 12-7/8 3 58 16d 20 10d 13785 9850 61.32 43.82 9787 6994 43.54 31.11<br />

THDH614 HGUS5.50/14 x 12 5-1/2 13 4 66 16d 22 16d 18810 10760 83.67 47.86 13355 7640 59.41 33.99<br />

5-1/4 x 16 - 22 HD5216 HU5.31/16 x 14 5-3/8 13-7/8 2-1/2 30 16d 12 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

6-3/4 x 9-1/4 - 14 THDH6710<br />

HGUS210-4,<br />

HGUS6.88/10<br />

x 12 6-7/8 8-13/16 4 46 16d 12 16d 13525 6575 60.16 29.25 9605 4670 42.73 20.77<br />

6-3/4 x 11-1/4 - 18 THDH6712<br />

HGUS212-4,<br />

HGUS6.88/12<br />

x 12 6-7/8 10-13/16 4 56 16d 14 16d 16130 9845 71.75 43.79 11450 6990 50.93 31.09<br />

6-3/4 x 14 - 20-1/2 THDH6714<br />

HGUS214-4,<br />

HGUS6.88/14<br />

x 12 6-7/8 12-13/16 4 66 16d 16 16d 16130 11335 71.75 50.42 11450 8050 50.93 35.81<br />

HD7100 HU410-2 x 14 7-1/8 9 2-1/2 12 16d 6 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

7 x 9-1/4 - 14<br />

THD7210 HHUS7.25/10 x 12 7-1/4 9 3 38 16d 20 10d 12455 6425 55.40 28.58 8843 4562 39.34 20.29<br />

THDH7210 HGUS7.25/10 x 12 7-1/4 9 4 46 16d 12 16d 14760 7480 65.66 33.27 10480 5310 46.62 23.62<br />

7 x 11-1/4 - 16<br />

7 x 14 - 20<br />

HD7120<br />

HD7140<br />

HU412-2<br />

HU414-2<br />

x<br />

x<br />

14<br />

14<br />

7-1/8<br />

7-1/8<br />

10-5/8<br />

13-1/8<br />

2-1/2<br />

2-1/2<br />

16<br />

20<br />

16d<br />

16d<br />

6<br />

8<br />

10d<br />

10d<br />

7215<br />

7215<br />

4435<br />

4435<br />

32.10<br />

32.10<br />

19.73<br />

19.73<br />

5123<br />

5123<br />

3149<br />

3149<br />

22.79<br />

22.79<br />

14.01<br />

14.01<br />

THDH7212<br />

THDH7214<br />

HGUS7.25/12<br />

HGUS7.25/14<br />

x<br />

x<br />

12<br />

12<br />

7-1/4<br />

7-1/4<br />

10-1/2<br />

12-1/4<br />

4<br />

4<br />

56<br />

66<br />

16d<br />

16d<br />

14<br />

16<br />

16d<br />

16d<br />

16130<br />

16130<br />

9845<br />

11335<br />

71.75<br />

71.75<br />

43.79<br />

50.42<br />

11450<br />

11450<br />

6990<br />

8050<br />

50.93<br />

50.93<br />

31.09<br />

35.81<br />

7 x 16 - 22 HD7160 -- -- x 14 7-1/8 15-5/8 2-1/2 24 16d 8 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

7 x 18 - 26 HD7180 -- -- x 14 7-1/8 17-3/4 2-1/2 28 16d 8 10d 7215 4435 32.10 19.73 5123 3149 22.79 14.01<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

<br />

4) NAILS<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

red font.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 123<br />

<strong>USP</strong>2240-131<br />

<strong>EWP</strong> <strong>Hangers</strong>


Top Mount hangers – BPH, TFI, TFL, & THO series<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

TFI & THO – Engineered for I-Joist to header applications. Offers full lateral<br />

support of the I-Joist top chord, eliminating the need for web stiffeners in most<br />

applications. Raised dimple nailing guides help assure correct 45° nailing into the<br />

I-Joist bottom flange. The THO’s feature the Seat Cleat® that allows for quick,<br />

positive seating. The Seat Cleat® will hold the I-Joist in place, eliminating spring<br />

back during nailing in the bottom flange.<br />

TFL – Features 11/2˝ top flange depth that accommodates all header types as well<br />

as back-to-back installations. Also features <strong>USP</strong>’s Seat Cleat® for quick, positive<br />

seating.<br />

BPH – These hangers are used to support LVL, LSL, and PSL beams and<br />

headers in light-to-medium load conditions.<br />

Materials: See <strong>EWP</strong> Top Mount <strong>Hangers</strong> charts, pages 128-142.<br />

Finish: G90 galvanizing<br />

Options See BPH Specialty Options Chart on page 125.<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Refer to the top mount chart for applications requiring web stiffeners.<br />

• Requirements for web stiffener from the I-Joist manufacturer should be followed,<br />

even if web stiffeners are not required in <strong>USP</strong> literature.<br />

• For BPH welded installation, see page 213.<br />

Typical TFL<br />

installation<br />

2˝<br />

H<br />

1 1 /2˝<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

W<br />

D<br />

TFL<br />

TFI<br />

Typical BPH<br />

installation<br />

Typical THO<br />

installation<br />

Slant Nailing<br />

via dimple<br />

nail holes<br />

Seat Cleat® helps<br />

lock I-Joist into place<br />

for positive seating<br />

and nailing ease.<br />

H<br />

TF<br />

H<br />

TF<br />

Diamond<br />

holes<br />

W<br />

D<br />

BPH<br />

W<br />

THO<br />

D<br />

124<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

continued on next page


Top Mount <strong>Hangers</strong> – BPH, TFI, TFL, & THO series continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Nailer Options – chart represents maximum factored resistance<br />

for hangers used on wood nailers. Reference page 117.<br />

TFL<br />

<strong>USP</strong><br />

Series<br />

THO<br />

THO (Double)<br />

<br />

THO (Double)<br />

<br />

TFI<br />

BPH<br />

Nailer<br />

Size<br />

Fastener Schedule<br />

Header<br />

Joist<br />

DF-L (Lbs)<br />

Factored Resistance 2<br />

DF-L (kN)<br />

S-P-F (Lbs)<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

2X 6 10d x 1-1/2 2 10d x 1-1/2 1830 265 8.14 1.18 1575 230 7.01 1.02<br />

3X 6 16d x 2-1/2 2 10d x 1-1/2 2305 265 10.25 1.18 1980 230 8.81 1.02<br />

(2) 2X 6 10d 2 10d x 1-1/2 1845 265 8.21 1.18 1585 230 7.05 1.02<br />

4X 6 16d 2 10d x 1-1/2 2535 265 11.28 1.18 2180 230 9.70 1.02<br />

2X 6 10d x 1-1/2 2 10d x 1-1/2 1960 375 8.72 1.67 1685 325 7.50 1.45<br />

3X 6 16d x 2-1/2 2 10d x 1-1/2 2115 375 9.41 1.67 1820 325 8.10 1.45<br />

(2) 2X 6 10d 2 10d x 1-1/2 1965 375 8.74 1.67 1690 325 7.52 1.45<br />

4X 6 16d 2 10d x 1-1/2 2210 375 9.83 1.67 1900 325 8.45 1.45<br />

2X 6 10d x 1-1/2 6 10d 2095 375 9.32 1.67 1800 325 8.01 1.45<br />

3X 6 16d x 2-1/2 6 10d 3360 520 14.95 2.31 2890 445 12.86 1.98<br />

(2) 2X 10 10d 6 10d 3415 520 15.19 2.31 2935 445 13.06 1.98<br />

4X 10 16d 6 10d 3840 520 17.08 2.31 3300 445 14.68 1.98<br />

2X 6 10d x 1-1/2 6 10d 2095 375 9.32 1.67 1800 325 8.01 1.45<br />

3X 6 16d x 2-1/2 6 10d 3360 520 14.95 2.31 2890 445 12.86 1.98<br />

(2) 2X 10 10d 6 10d 3415 520 15.19 2.31 2935 445 13.06 1.98<br />

4X 10 16d 6 10d 3840 520 17.08 2.31 3300 445 14.68 1.98<br />

4X 6 16d 2 10d x 1-1/2 3685 375 16.39 1.67 3170 325 14.10 1.45<br />

4X 10 16d 2 10d x 1-1/2 4675 375 20.80 1.67 4020 325 17.88 1.45<br />

2X 6 10d x 1-1/2 4 10d x 1-1/2 2995 240 13.32 1.07 2575 205 11.45 0.91<br />

3X 8 16d x 2-1/2 4 10d x 1-1/2 3400 555 15.12 2.47 2925 475 13.01 2.11<br />

(2) 2X 8 10d 4 10d x 1-1/2 3325 555 14.79 2.47 2860 475 12.72 2.11<br />

4X 8 16d 4 10d x 1-1/2 3235 555 14.39 2.47 2780 475 12.37 2.11<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake;<br />

reduce for other load durations in accordance with the code.<br />

2) Listed loads shall not be increased.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) NAILS:<br />

S-P-F (kN)<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

BPH Specialty Options Chart – refer to Specialty<br />

Options pages 210 to 211 for additional details.<br />

Option Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Sloped Top Flange 4<br />

Range <br />

Factored<br />

Resistance<br />

Ordering<br />

<br />

SK, <br />

(R) (L),<br />

<br />

<br />

SL, <br />

(U) (D),<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

SF, <br />

(R) (L),<br />

<br />

<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 125<br />

<strong>USP</strong>2240-131


Beam <strong>Hangers</strong> – HLBH series<br />

Heavy-duty hanger for LVL, LSL, and PSL beams.<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Materials: See <strong>EWP</strong> Top Mount <strong>Hangers</strong> charts,<br />

pages 132-136, 138-142.<br />

Finish: <strong>USP</strong> primer<br />

Options: See Specialty Options Chart.<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• For welded installations, see page 213.<br />

• 16d ring shank nails are supplied with HLBH hangers<br />

HLBH Nailer Options – chart represents maximum factored resistance<br />

for hangers used on wood nailers. Reference page 117.<br />

Fastener Schedule 3<br />

Factored Resistance 2<br />

Header Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs)<br />

S-P-F (kN)<br />

<strong>USP</strong><br />

Series<br />

Nailer<br />

Size Qty Type Qty Type<br />

Vertical<br />

100%<br />

Uplift 1<br />

115%<br />

Vertical<br />

100%<br />

Uplift 1<br />

115%<br />

Vertical<br />

100%<br />

Uplift 1<br />

115%<br />

Vertical<br />

100%<br />

Uplift 1<br />

115%<br />

HLBH<br />

4X 15 NA16D-RS 6 10d x 1-1/2 13825 1430 61.50 6.36 12840 1235 57.12 5.49<br />

4X 15 NA16D-RS 6 16d 13825 1770 61.50 7.87 12840 1430 57.12 6.36<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake;<br />

reduce for other load durations in accordance with the code.<br />

2) Listed loads shall not be increased.<br />

3) NAILS<br />

red font.<br />

4 3 /8˝<br />

Typical HLBH<br />

installation<br />

W<br />

L<br />

D<br />

HLBH<br />

H<br />

TF<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Specialty Options Chart – refer to Specialty Options pages 210 and 212 for additional details.<br />

Option Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Sloped Top Flange 4 Top Flange Offset Saddle 5 Ridge<br />

Range <br />

<br />

<br />

<br />

<br />

Factored<br />

<br />

<br />

<br />

Resistance<br />

<br />

<br />

<br />

See footnote 5.<br />

<br />

<br />

Ordering<br />

SK, <br />

(R) (L),<br />

<br />

<br />

SL, <br />

(U) (D),<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

SF, <br />

(R) (L),<br />

<br />

<br />

S, <br />

(R) (L),<br />

<br />

<br />

SA, <br />

<br />

<br />

<br />

DA, <br />

<br />

<br />

<br />

Top Flange <strong>Hangers</strong> – MPH, PHM & PHXU series<br />

MPH – Designed to work with standard 6˝ or larger grouted concrete block wall construction. Eliminates<br />

the need for masons to fabricate special seats to support I-Joists or composite wood beams.<br />

PHM & PHXU – Used to connect LVL, LSL, and PSL beams to headers in medium load conditions<br />

using standard nails.<br />

Install with (2)<br />

16d duplex nails<br />

in grouted cells<br />

Materials: See <strong>EWP</strong> Top Mount <strong>Hangers</strong> charts, pages 128-142.<br />

Finish: <strong>USP</strong> primer; PHXU – G90 galvanizing<br />

Options: See Speciality Options Chart on page 127.<br />

Codes: Load values are derived from data submitted tvarious<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• For MPH series: 16d duplex nails are not provided. Place hanger on top of concrete block. Install<br />

(2) 16d duplex nails (8 gauge or 0.162˝ dia. x 31⁄2˝ double head) in the grouted cavity, and then<br />

continue laying the next course of block. Larger holes on top flange are provided to aid grout flow. A<br />

minimum of one course must be laid over hanger top flange and one course below hanger top<br />

flange. Courses adjacent to the top flange shall be subsequently grouted.<br />

• For PHM & PHXU welded installations, see page 213.<br />

126<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

Typical MPH<br />

installation<br />

continued on next page


Top Flange <strong>Hangers</strong> – MPH, PHM, & PHXU series cont.<br />

L<br />

H<br />

TF<br />

L<br />

H<br />

3 3 /4˝<br />

L<br />

H<br />

TF<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>USP</strong><br />

Series<br />

PHM<br />

W<br />

PHXU<br />

<br />

PHXU<br />

<br />

PHM<br />

D<br />

Fastener Schedule 3<br />

W<br />

MPH<br />

2 1 /2˝<br />

W<br />

PHXU<br />

PHM & PHXU Nailer Options – chart represents maximum factored resistance<br />

for hangers used on wood nailers. Reference page 117.<br />

Factored Resistance 2<br />

Header Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Nailer<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Size Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

2X 2 10d x 1-1/2 2 10d x 1-1/2 4335 -- -- 19.28 -- -- 3730 -- -- 16.59 -- --<br />

3X 2 16d x 2-1/2 2 10d x 1-1/2 5140 -- -- 22.86 -- -- 4420 -- -- 19.66 -- --<br />

(2) 2X 2 10d 2 10d x 1-1/2 4790 -- -- 21.31 -- -- 4120 -- -- 18.33 -- --<br />

4X 2 16d 2 10d x 1-1/2 4685 -- -- 20.84 -- -- 4030 -- -- 17.93 -- --<br />

4X 8 16d 6 10d x 1-1/2 6370 1210 28.34 5.38 4420 920 19.66 4.09<br />

4X 8 16d 6 10d x 1-1/2 7610 1005 33.85 4.47 5170 865 23.00 3.85<br />

4X 8 16d 6 10d 7610 1290 33.85 5.74 5170 1150 23.00 5.12<br />

<br />

<br />

<br />

3) NAILS<br />

red font.<br />

D<br />

Typical PHXU<br />

installation<br />

Specialty Options Chart – refer to Specialty Options pages 210 and 212 for additional details.<br />

Option <strong>USP</strong> Series Skewed 1,3,5 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Sloped Top Flange 4 Top Flange Offset 5,7 Saddle 5,6 Ridge<br />

Range<br />

Factored<br />

Resistance<br />

Ordering<br />

PHM <br />

<br />

<br />

PHXU<br />

<br />

<br />

N/A<br />

<br />

<br />

MPH N/A N/A<br />

PHM<br />

PHXU<br />

MPH<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

7) PHXU offset option - hanger will be welded with a closed top angle, not formed.<br />

red font.<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

See footnote 6.<br />

<br />

SA,<br />

DA, and<br />

SK,<br />

SL,<br />

SF,<br />

OS, and<br />

<br />

<br />

PHM <br />

(R) (L), <br />

(R) (L), (U) (D),<br />

<br />

(R) (L),<br />

<br />

<br />

PHXU<br />

<br />

N/A<br />

<br />

MPH N/A N/A<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 127<br />

<strong>USP</strong>2240-131


<strong>EWP</strong> Top Mount Hanger Charts<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Joist Size<br />

1-1/2 x 9-1/4<br />

1-1/2 x 9-1/2<br />

1-1/2 x 11-1/4<br />

<strong>USP</strong><br />

Stock No. Ref. No.<br />

THO15925 LT15925 --<br />

BPH15925<br />

THO15950<br />

BPH1595<br />

MPH1595<br />

BPH15112<br />

MPH212<br />

LBV1.56/9.25<br />

MPH210 WM29.25<br />

LT159<br />

LBV1.56/9.5,<br />

MIT29.5<br />

WM29.5<br />

LBV1.56/11.25<br />

WM211.25<br />

Web Stiffener Reqd.<br />

x<br />

--<br />

--<br />

x<br />

--<br />

x<br />

--<br />

Steel Gauge<br />

18<br />

12<br />

12<br />

18<br />

12<br />

12<br />

12<br />

12<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header<br />

Joist<br />

Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

1-9/16 9-1/4 2 -- 1-1/2 6 10d 2 10d x 1-1/2<br />

1-9/16<br />

1-9/16<br />

1-1/2 9-1/2 2 -- 1-1/2 6 10d 2 10d x 1-1/2<br />

1-9/16<br />

1-9/16<br />

1-9/16<br />

1-9/16<br />

9-1/4<br />

9-1/4<br />

9-1/2<br />

9-1/2<br />

11-1/4<br />

11-1/4<br />

2-3/8<br />

2-1/2<br />

2-3/8<br />

2-1/2<br />

2-3/8<br />

2-1/2<br />

--<br />

7<br />

--<br />

7<br />

--<br />

1-1/2<br />

3-3/4<br />

1-1/2<br />

3-3/4<br />

1-1/2<br />

10<br />

10<br />

16d 4<br />

7 3-3/4 2 16d duplex<br />

10 16d 4 10d x 1-1/2<br />

2 16d duplex 2 10d x 1-1/2<br />

16d 4 10d x 1-1/2<br />

16d duplex 2 10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs 1445 1935 1860 1920 1645 1170 -- 435<br />

kN 6.43 8.61 8.27 8.54 7.32 5.20 -- 1.94<br />

Lbs -- 4415 4415 4415 3780 2865 -- 780<br />

kN -- 19.64 19.64 19.64 16.81 12.74 -- 3.47<br />

Lbs -- -- -- -- -- -- 3745 --<br />

kN -- -- -- -- -- -- 16.66 --<br />

Lbs 1815 1935 1860 1920 1790 1270 -- 505<br />

kN 8.07 8.61 8.27 8.54 7.96 5.65 -- 2.25<br />

Lbs -- 4415 4415 4415 3780 2865 -- 780<br />

kN -- 19.64 19.64 19.64 16.81 12.74 -- 3.47<br />

Lbs -- -- -- -- -- -- 3745 --<br />

kN -- -- -- -- -- -- 16.66 --<br />

Lbs -- 4415 4415 4415 3780 2865 -- 780<br />

kN -- 19.64 19.64 19.64 16.81 12.74 -- 3.47<br />

Lbs -- -- -- -- -- -- 3745 --<br />

kN -- -- -- -- -- -- 16.66 --<br />

THO15118<br />

LT151188,<br />

Lbs 1880 1935 1860 1920 1975 1405 -- 505<br />

-- 18 1-1/2 11-7/8 2 -- 1-9/16 6 10d 2 10d x 1-1/2<br />

MIT211.88<br />

kN 8.36 8.61 8.27 8.54 8.79 6.25 -- 2.25<br />

1-1/2 x 11-7/8<br />

Lbs -- 4415 4415 4415 3780 2865 -- 780<br />

BPH15118 LBV1.56/11.88 x 12 1-9/16 11-7/8 2-3/8 -- 1-1/2 10 16d 4 10d x 1-1/2<br />

kN -- 19.64 19.64 19.64 16.81 12.74 -- 3.47<br />

MPH15118 WM211.88 -- 12 1-9/16 11-7/8 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2<br />

Lbs -- -- -- -- -- -- 3745 --<br />

kN -- -- -- -- -- -- 16.66 --<br />

THO15140 -- -- -- 16 1-9/16 14 2-3/8 -- 1-1/2 10 10d 2 10d x 1-1/2<br />

Lbs 1485 1485 1485 1485 1690 1200 -- 435<br />

kN 6.61 6.61 6.61 6.61 7.52 5.34 -- 1.94<br />

1-1/2 x 14 BPH1514 LBV1.56/14 x 12 1-9/16 14 2-3/8 -- 1-1/2 10 16d 4 10d x 1-1/2<br />

Lbs -- 4415 4415 4415 3780 2865 -- 780<br />

kN -- 19.64 19.64 19.64 16.81 12.74 -- 3.47<br />

MPH1514 -- -- -- 12 1-9/16 14 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2<br />

Lbs -- -- -- -- -- -- 3745 --<br />

kN -- -- -- -- -- -- 16.66 --<br />

1-5/8 x 9-1/2 THO16950 -- -- -- 18 1-11/16 9-1/2 2 -- 1-1/2 6 10d 2 10d x 1-1/2<br />

Lbs 1445 1935 1860 1920 1645 1170 -- 435<br />

kN 6.43 8.61 8.27 8.54 7.32 5.20 -- 1.94<br />

1-5/8 x 11-1/4 THO16112 -- -- -- 16 1-11/16 11-1/4 2 -- 1-1/2 6 10d 2 10d x 1-1/2<br />

Lbs 1485 1935 1860 1920 1690 1200 -- 435<br />

kN 6.61 8.61 8.27 8.54 7.52 5.34 -- 1.94<br />

1-5/8 x 11-7/8 THO16118 -- -- -- 16 1-11/16 11-7/8 2 -- 1-1/2 6 10d 2 10d x 1-1/2<br />

Lbs 1485 1935 1860 1920 1690 1200 -- 435<br />

kN 6.61 8.61 8.27 8.54 7.52 5.34 -- 1.94<br />

1-5/8 x 14 THO16140 -- -- -- 16 1-11/16 14 3 -- 1-3/4 10 10d 2 10d x 1-1/2<br />

Lbs 1485 1485 1485 1485 1690 1200 -- 435<br />

kN 6.61 6.61 6.61 6.61 7.52 5.34 -- 1.94<br />

1-3/4 x 7-1/4 PHXU17725<br />

LBV1.81/7.25,<br />

Lbs -- 6370 6370 6370 6370 4420 -- 1210<br />

x 7 1-13/16 7-1/4 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2<br />

WP1.81/7.25<br />

kN -- 28.34 28.34 28.34 28.34 19.66 -- 5.38<br />

BPH17925 LBV1.81/9.25 x 12 1-13/16 9-1/4 2-3/8 -- 1-11/16 10 16d 4 10d x 1-1/2<br />

Lbs -- 4890 4890 4890 4320 3235 -- 780<br />

kN -- 21.75 21.75 21.75 19.22 14.39 -- 3.47<br />

1-3/4 x 9-1/4 PHM17925 WP9.25 x 7/10 1-13/16 9-1/4 2-1/2 7 3 2 16d 2 10d x 1-1/2<br />

Lbs -- 5090 4795 4435 4125 4125 -- --<br />

kN -- 22.64 21.33 19.73 18.35 18.35 -- --<br />

PHXU17925 WPU1.81/9.25 x 7 1-13/16 9-1/4 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2<br />

Lbs -- 6370 6370 6370 6370 4420 -- 1210<br />

kN -- 28.34 28.34 28.34 28.34 19.66 -- 5.38<br />

THO17950<br />

LT179,<br />

Lbs 1570 1935 1860 1920 2195 1560 -- 505<br />

-- 18 1-3/4 9-1/2 2 -- 1-1/2 6 10d 2 10d x 1-1/2<br />

ITS1.81/9.5<br />

kN 6.98 8.61 8.27 8.54 9.76 6.94 -- 2.25<br />

BPH1795<br />

LBV1.81/9.5,<br />

Lbs -- 4890 4890 4890 4320 3235 -- 780<br />

x 12 1-13/16 9-1/2 2-3/8 -- 1-11/16 10 16d 4 10d x 1-1/2<br />

MIT9.5<br />

kN -- 21.75 21.75 21.75 19.22 14.39 -- 3.47<br />

1-3/4 x 9-1/2<br />

Lbs -- 5090 4795 4435 4125 4125 -- --<br />

PHM1795 WP9 x 7/10 1-13/16 9-1/2 2-1/2 7 3 2 16d 2 10d x 1-1/2<br />

kN -- 22.64 21.33 19.73 18.35 18.35 -- --<br />

PHXU1795 -- -- x 7 1-13/16 9-1/2 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2<br />

Lbs -- 6370 6370 6370 6370 4420 -- 1210<br />

kN -- 28.34 28.34 28.34 28.34 19.66 -- 5.38<br />

MPH1795 WM9 -- 12 1-13/16 9-1/2 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2<br />

Lbs -- -- -- -- -- -- 4305 --<br />

kN -- -- -- -- -- -- 19.15 --<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

L<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

TF<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

H<br />

2<br />

2<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

W<br />

D<br />

continued on next page<br />

128<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Joist Size<br />

1-3/4 x 11-1/4<br />

1-3/4 x 11-7/8<br />

1-3/4 x 14<br />

1-3/4 x 16<br />

2 - 2-1/8<br />

x 9-1/2<br />

2 - 2-1/8<br />

x 11-7/8<br />

<strong>USP</strong><br />

Stock No.<br />

BPH17112<br />

PHM17112<br />

PHXU17112<br />

THO17118<br />

BPH17118<br />

PHM17118<br />

PHXU17118<br />

MPH17118<br />

TFL1714<br />

BPH1714<br />

PHM1714<br />

PHXU1714<br />

MPH1714<br />

TFL1716<br />

BPH1716<br />

PHM1716<br />

MPH1716<br />

TFL2095<br />

TFL20118<br />

Ref. No.<br />

LBV1.81/11.25<br />

WPU1.81/11.25<br />

LT171188,<br />

ITS1.81/11.88,<br />

MIT11.88<br />

BA1.81/11.88,<br />

LBV1.81/11.88<br />

WP11<br />

WPU1.81/11.88<br />

WM11<br />

WP14<br />

WPU1.81/14<br />

WM14<br />

LT1716,<br />

ITS1.81/16<br />

B1.81/16,<br />

LBV1.81/16,<br />

MIT1.81/16<br />

--<br />

x<br />

--<br />

Steel Gauge<br />

WP16 x 7/10<br />

WM16<br />

-- --<br />

LT1714,<br />

ITS1.81/14<br />

LBV1.81/14,<br />

MIT1.81/14<br />

LT209,<br />

ITS2.06/9.5<br />

LT2011.88,<br />

ITS2.06/11.88<br />

Web Stiffener Reqd.<br />

--<br />

--<br />

--<br />

18<br />

12<br />

12 1-13/16<br />

18 2-1/8<br />

18<br />

1-3/4<br />

1-13/16<br />

1-13/16<br />

1-13/16<br />

1-13/16<br />

1-3/4<br />

1-13/16 16 2-1/2<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header<br />

Joist<br />

Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

x 12 1-13/16 11-1/4 2-3/8 -- 1-11/16 10 16d 4 10d x 1-1/2<br />

Lbs -- 4890 4890 4890 4320 3235 -- 780<br />

kN -- 21.75 21.75 21.75 19.22 14.39 -- 3.47<br />

x 7/10 1-13/16 11-1/4 2-1/2 7 3 2 16d 2 10d x 1-1/2<br />

Lbs -- 5090 4795 4435 4125 4125 -- --<br />

kN -- 22.64 21.33 19.73 18.35 18.35 -- --<br />

x 7 1-13/16 11-1/4 3-1/4 10 2-1/2 8 16d 6 10d x 1-1/2<br />

Lbs -- 6370 6370 6370 6370 4420 -- 1210<br />

kN -- 28.34 28.34 28.34 28.34 19.66 -- 5.38<br />

Lbs 1735 1935 1860 1920 2195 1555 -- 505<br />

-- 18 1-3/4 11-7/8 2 -- 1-9/16 6 10d 2 10d x 1-1/2<br />

kN 7.72 8.61 8.27 8.54 9.76 6.92 -- 2.25<br />

x 12<br />

x 7/10<br />

x 7<br />

-- 12<br />

--<br />

x<br />

x<br />

x<br />

18<br />

12<br />

7/10<br />

7<br />

12<br />

1-13/16<br />

1-13/16<br />

1-13/16<br />

16<br />

2 --<br />

1-13/16 16 2-3/8 --<br />

2-1/8<br />

11-7/8 2-3/8<br />

11-7/8 2-1/2<br />

11-7/8 3-1/4<br />

14<br />

14<br />

14<br />

14<br />

14<br />

16<br />

9-1/2<br />

2-1/2<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

2<br />

2-3/8<br />

2-1/2<br />

3-1/4<br />

2-1/2<br />

11-7/8 2<br />

--<br />

7<br />

10<br />

--<br />

--<br />

7<br />

10<br />

7<br />

7<br />

7<br />

1-1/2<br />

2-1/2<br />

1-11/16<br />

3<br />

3-3/4<br />

2 -- 1-1/2<br />

--<br />

1-11/16<br />

1-13/16 11-7/8 2-1/2 7 3-3/4 2 16d duplex<br />

3<br />

2-1/2<br />

1-11/16<br />

3<br />

3-3/4<br />

1-1/2<br />

1-1/2<br />

10 16d 4 10d x 1-1/2<br />

2 16d 2 10d x 1-1/2<br />

8 16d 6 10d x 1-1/2<br />

6<br />

2 16d duplex 2<br />

2<br />

10d x 1-1/2<br />

10 16d 4 10d x 1-1/2<br />

2<br />

8<br />

6 10d<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10 16d 4 10d x 1-1/2<br />

2 16d 2 10d x 1-1/2<br />

2 16d duplex 2<br />

6<br />

10d 2<br />

10d<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

6 10d 2 10d x 1-1/2<br />

2<br />

16d 2<br />

16d 6<br />

2<br />

10d x 1-1/2<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs -- 4890 4890 4890 4320 3235 -- 780<br />

kN -- 21.75 21.75 21.75 19.22 14.39 -- 3.47<br />

Lbs -- 5090 4795 4435 4125 4125 -- --<br />

kN -- 22.64 21.33 19.73 18.35 18.35 -- --<br />

Lbs -- 6370 6370 6370 6370 4420 -- 1210<br />

kN -- 28.34 28.34 28.34 28.34 19.66 -- 5.38<br />

Lbs -- -- -- -- -- -- 4305 --<br />

kN -- -- -- -- -- -- 19.15 --<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs -- 4890 4890 4890 4320 3235 -- 780<br />

kN -- 21.75 21.75 21.75 19.22 14.39 -- 3.47<br />

Lbs -- 5090 4795 4435 4125 4125 -- --<br />

kN -- 22.64 21.33 19.73 18.35 18.35 -- --<br />

Lbs -- 6370 6370 6370 6370 4420 -- 1210<br />

kN -- 28.34 28.34 28.34 28.34 19.66 -- 5.38<br />

Lbs -- -- -- -- -- -- 4305 --<br />

kN -- -- -- -- -- -- 19.15 --<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs -- 4890 4890 4890 4320 3235 -- 780<br />

kN -- 21.75 21.75 21.75 19.22 14.39 -- 3.47<br />

Lbs -- 5090 4795 4435 4125 4125 -- --<br />

kN -- 22.64 21.33 19.73 18.35 18.35 -- --<br />

Lbs -- -- -- -- -- -- 4305 --<br />

kN -- -- -- -- -- -- 19.15 --<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

L<br />

TF<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

H<br />

W<br />

D<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 129<br />

<strong>USP</strong>2240-131


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Joist Size<br />

2 - 2-1/8 x 14<br />

2 - 2-1/8 x 16<br />

2-1/4 - 2-5/16<br />

x 9-1/2<br />

2-1/4 - 2-5/16<br />

x 11-7/8<br />

2-1/4 - 2-5/16<br />

x 14<br />

2-1/4 - 2-5/16<br />

x 16<br />

2-1/4 - 2-5/16<br />

x 18<br />

2-1/4 - 2-5/16<br />

x 20<br />

2-1/2 x 9-1/4<br />

<strong>USP</strong><br />

Stock No.<br />

Ref. No.<br />

Steel Gauge<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header<br />

Joist<br />

Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

2-1/2 x 9-3/8 TFL25938 LT259375 -- 18 2-1/2 9-3/8 2 -- 1-1/2 6 10d 2<br />

2-1/2 x 9-1/2<br />

TFL2014<br />

TFL2314<br />

TFI3518<br />

TFL2595<br />

LT214,<br />

ITS2.06/14<br />

TFL2016 LT2016<br />

TFL2395<br />

TFL23118<br />

LT2314,<br />

ITS2.37/14<br />

THO23140 LBV2.37/14<br />

TFI3514 MIT3514<br />

PHM2314 WP3514<br />

MPH2314 -- --<br />

TFL2316 -- --<br />

TFI3516 MIT3516<br />

PHM2316 WP3516<br />

MPH2316 -- --<br />

PHM2318 WP3518<br />

TFI3520<br />

LT239,<br />

ITS2.37/9.5<br />

MPH2395 -- --<br />

LT231188,<br />

ITS2.37/11.88<br />

MPH23118 WM3511.88<br />

HIT3518,<br />

LBV2.37/18,<br />

MIT3518<br />

MPH2318 -- --<br />

HIT3520,<br />

LBV2.37/20,<br />

MIT3520<br />

PHM2320 WP3520<br />

MPH2320 -- --<br />

TFL25925 LT25925<br />

MPH25925 -- --<br />

LT259,<br />

ITS2.56/9.5<br />

MPH2595 -- --<br />

Web Stiffener Reqd.<br />

-- 18<br />

-- 18<br />

-- 18<br />

-- 12<br />

-- 18<br />

18<br />

-- 16<br />

x 7/10<br />

-- 12<br />

-- 18<br />

-- 16<br />

x 7/10<br />

-- 12<br />

-- 18<br />

-- 12<br />

2-5/16<br />

2-3/8<br />

-- 12 2-3/8<br />

-- 18<br />

--<br />

-- 16<br />

x 7/10<br />

x 12<br />

-- 16<br />

x 7/10<br />

x 12<br />

-- 18<br />

-- 12<br />

2-1/8<br />

2-1/8<br />

2-5/16<br />

2-5/16<br />

2-3/8<br />

2-3/8<br />

2-3/8<br />

2-1/2<br />

16<br />

20<br />

20<br />

9-1/4<br />

9-1/4<br />

2-1/2 9-1/2 2 -- 1-1/2 6<br />

2-1/2 9-1/2<br />

3-3/4 2 16d duplex<br />

10d 2 10d x 1-1/2<br />

10d x 1-1/2<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

New products or updated product information are designated in red font.<br />

2-3/8<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

2<br />

2-1/2<br />

2-1/2<br />

7<br />

7<br />

2-1/16<br />

18 2-1/2 7 3<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

--<br />

--<br />

2-3/8 14 2-1/2 7 3 2 16d<br />

2-3/8<br />

2-5/16<br />

2-3/8<br />

2-3/8<br />

2-3/8<br />

14 2<br />

14<br />

14<br />

16<br />

16<br />

16<br />

2<br />

2-1/2<br />

7<br />

--<br />

--<br />

7<br />

7<br />

--<br />

7<br />

--<br />

7<br />

--<br />

7<br />

1-1/2<br />

2<br />

3-3/4<br />

1-1/2<br />

2-1/16<br />

3<br />

3-3/4<br />

3-3/4<br />

2-1/16<br />

3<br />

3-3/4<br />

1-1/2<br />

3-3/4<br />

6 10d<br />

2-3/8 14 2-1/2 -- 2-1/16 6 16d<br />

2-3/8<br />

2-3/8<br />

2-3/8<br />

2-3/8<br />

2-1/2<br />

14<br />

16<br />

9-1/2<br />

9-1/2<br />

11-7/8<br />

11-7/8<br />

18<br />

18<br />

20<br />

2 --<br />

2 --<br />

2 --<br />

2-1/2<br />

2<br />

2-1/2<br />

7<br />

--<br />

1-1/2<br />

1-1/2<br />

1-1/2<br />

3-3/4<br />

1-1/2<br />

7 3-3/4<br />

6 10d<br />

6 10d 2<br />

2 16d duplex 2<br />

6 10d<br />

6<br />

16d 2<br />

2 16d duplex<br />

2<br />

2<br />

2 10d x 1-1/2<br />

2 10d x 1-1/2<br />

2<br />

2<br />

2<br />

10d x 1-1/2<br />

6 10d 2 10d x 1-1/2<br />

6 10d 2 10d x 1-1/2<br />

2 16d duplex 2 10d x 1-1/2<br />

10d x 1-1/2<br />

2 16d duplex 2 10d x 1-1/2<br />

2 10d x 1-1/2<br />

12 10d 2 10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

2 16d 2 10d x 1-1/2<br />

6<br />

10d x 1-1/2<br />

2 10d x 1-1/2<br />

6 16d 2 10d x 1-1/2<br />

2<br />

6<br />

16d 2<br />

2 16d 2<br />

16d duplex<br />

16d 2 10d x 1-1/2<br />

2 16d duplex 2 10d x 1-1/2<br />

10d 2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

2 16d duplex 2 10d x 1-1/2<br />

10d x 1-1/2<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 --<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs -- -- -- -- -- -- 5565 --<br />

kN -- -- -- -- -- -- 24.76 --<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs -- -- -- -- -- -- 5565 --<br />

kN -- -- -- -- -- -- 24.76 --<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs 3865 3865 3865 3865 4450 3160 -- 500<br />

kN 17.19 17.19 17.19 17.19 19.80 14.06 -- 2.22<br />

Lbs -- 3685 3220 3260 4190 2975 -- 545<br />

kN -- 16.39 14.32 14.50 18.64 13.23 -- 2.42<br />

Lbs -- 5140 5140 4435 4125 4125 -- --<br />

kN -- 22.86 22.86 19.73 18.35 18.35 -- --<br />

Lbs -- -- -- -- -- -- 5565 --<br />

kN -- -- -- -- -- -- 24.76 --<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs -- 3685 3220 3260 4190 2975 -- 545<br />

kN -- 16.39 14.32 14.50 18.64 13.23 -- 2.42<br />

Lbs -- 5140 5140 4435 4125 4125 -- --<br />

kN -- 22.86 22.86 19.73 18.35 18.35 -- --<br />

Lbs -- -- -- -- -- -- 5565 --<br />

kN -- -- -- -- -- -- 24.76 --<br />

Lbs -- 3685 3220 3260 4190 2975 -- 545<br />

kN -- 16.39 14.32 14.50 18.64 13.23 -- 2.42<br />

Lbs -- 5140 5140 4435 4125 4125 -- --<br />

kN -- 22.86 22.86 19.73 18.35 18.35 -- --<br />

Lbs -- -- -- -- -- -- 5565 --<br />

kN -- -- -- -- -- -- 24.76 --<br />

Lbs -- 3685 3220 3260 4190 2975 -- 545<br />

kN -- 16.39 14.32 14.50 18.64 13.23 -- 2.42<br />

Lbs -- 5140 5140 4435 4125 4125 -- --<br />

kN -- 22.86 22.86 19.73 18.35 18.35 -- --<br />

Lbs -- -- -- -- -- -- 5565 --<br />

kN -- -- -- -- -- -- 24.76 --<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs -- -- -- -- -- -- 5990 --<br />

kN -- -- -- -- -- -- 26.65 --<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs -- -- -- -- -- -- 5990 --<br />

kN -- -- -- -- -- -- 26.65 --<br />

L<br />

H<br />

TF<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

W<br />

D<br />

continued on next page<br />

130<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Joist Size<br />

2-1/2 x 11-1/4<br />

2-1/2 x 11-7/8<br />

2-1/2 x 13<br />

2-1/2 x 14<br />

2-1/2 x 16<br />

2-1/2 x 18<br />

2-1/2 x 20<br />

2-1/2 x 22<br />

<strong>USP</strong><br />

Stock No.<br />

TFL25112<br />

MPH25112<br />

TFL25118<br />

THO25118<br />

MPH25118<br />

TFL2513<br />

TFL2514<br />

THO25140<br />

Ref. No.<br />

Steel Gauge<br />

TFI314 MIT314 -- 16 2-9/16 14 2-1/2 -- 2<br />

PHM2514<br />

MPH2514<br />

TFL2516<br />

TFI316<br />

PHM2516<br />

MPH2516<br />

TFI318<br />

MPH2518<br />

TFI320<br />

LT251125<br />

MIT311.88<br />

LT2513<br />

-- --<br />

<br />

ITS2.56/11.88<br />

-- --<br />

<br />

ITS2.56/14<br />

-- --<br />

-- 18<br />

-- 12<br />

-- 18<br />

-- 16<br />

-- 12<br />

-- 18<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header<br />

Joist<br />

Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

2-1/2 11-1/4 2<br />

2-1/2 11-1/4<br />

2-1/2<br />

2-9/16<br />

2-1/2 11-7/8<br />

2-1/2<br />

11-7/8 2<br />

11-7/8 2-3/8<br />

2-1/2 7 3-3/4<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

3) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

4) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

New products or updated product information are designated in red font.<br />

2-1/2<br />

WPI314 -- 7/10 2-9/16 14 2-1/2<br />

-- --<br />

-- 18<br />

-- 18<br />

-- 12<br />

2-1/2<br />

2-9/16<br />

13<br />

14<br />

14<br />

2<br />

--<br />

--<br />

--<br />

7<br />

1-1/2<br />

1-1/2<br />

1-15/16<br />

3-3/4<br />

-- 1-1/2<br />

--<br />

--<br />

7 3<br />

2-1/2 14 2-1/2 7 3-3/4<br />

2-1/2<br />

2-9/16<br />

2-1/2<br />

2-1/2<br />

MPH2520 -- -- x 12 2-1/2 20 2-1/2 7<br />

TFI322<br />

MPH2522<br />

LT2516<br />

<br />

MIT316<br />

WPI316<br />

-- --<br />

<br />

<br />

MIT318<br />

-- --<br />

<br />

<br />

MIT320<br />

<br />

<br />

WPI322<br />

-- --<br />

Web Stiffener Reqd.<br />

-- 18<br />

-- 16<br />

-- 7/10<br />

--<br />

12<br />

-- 16<br />

x 12<br />

-- 16<br />

-- 16<br />

2-9/16<br />

2-9/16<br />

2-1/2<br />

2-9/16<br />

2-9/16<br />

16<br />

16<br />

16<br />

16<br />

18<br />

18<br />

20<br />

2<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

x 12 2-1/2 22 2-1/2<br />

2<br />

2-3/8<br />

22 2-1/2<br />

--<br />

--<br />

7<br />

7<br />

--<br />

7<br />

--<br />

--<br />

7<br />

1-1/2<br />

2<br />

1-1/2<br />

2<br />

3<br />

3-3/4<br />

2<br />

3-3/4<br />

2<br />

3-3/4<br />

2<br />

3-3/4<br />

6 10d<br />

10d x 1-1/2<br />

2 16d duplex 2 10d x 1-1/2<br />

10d x 1-1/2<br />

10 10d 2 10d x 1-1/2<br />

2<br />

6 10d 2<br />

2 16d duplex 2 10d x 1-1/2<br />

6<br />

6<br />

2<br />

10d 2 10d x 1-1/2<br />

10d<br />

2 10d x 1-1/2<br />

12 10d 2 10d x 1-1/2<br />

6 16d 2 10d x 1-1/2<br />

16d 2 10d x 1-1/2<br />

2 16d duplex 2 10d x 1-1/2<br />

6 10d 2<br />

6 16d 2 10d x 1-1/2<br />

2 16d 2<br />

2 16d duplex 2<br />

6<br />

2<br />

2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

2 16d duplex 2 10d x 1-1/2<br />

6 16d 2<br />

10d x 1-1/2<br />

2 16d duplex 2 10d x 1-1/2<br />

10 16d 2 10d x 1-1/2<br />

2<br />

16d<br />

16d duplex<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs -- -- -- -- -- -- 5990 --<br />

kN -- -- -- -- -- -- 26.65 --<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs 2950 2535 2535 2535 3005 2130 -- 435<br />

kN 13.12 11.28 11.28 11.28 13.37 9.48 -- 1.94<br />

Lbs -- -- -- -- -- -- 5990 --<br />

kN -- -- -- -- -- -- 26.65 --<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs 3865 3865 3865 3865 4450 3160 -- 435<br />

kN 17.19 17.19 17.19 17.19 19.80 14.06 -- 1.94<br />

Lbs -- 3685 3220 3260 4190 2975 -- 545<br />

kN -- 16.39 14.32 14.50 18.64 13.23 -- 2.42<br />

Lbs -- 5140 5140 4435 4125 4125 -- --<br />

kN -- 22.86 22.86 19.73 18.35 18.35 -- --<br />

Lbs -- -- -- -- -- -- 5990 --<br />

kN -- -- -- -- -- -- 26.65 --<br />

Lbs 1795 2370 2305 2450 2495 1771 -- 265<br />

kN 7.98 10.54 10.25 10.90 11.10 7.88 -- 1.18<br />

Lbs -- 3685 3220 3260 4190 2975 -- 545<br />

kN -- 16.39 14.32 14.50 18.64 13.23 -- 2.42<br />

Lbs -- 5140 5140 4435 4125 4125 -- --<br />

kN -- 22.86 22.86 19.73 18.35 18.35 -- --<br />

Lbs -- -- -- -- -- -- 5990 --<br />

kN -- -- -- -- -- -- 26.65 --<br />

Lbs -- 3685 3220 3260 4190 2975 -- 545<br />

kN -- 16.39 14.32 14.50 18.64 13.23 -- 2.42<br />

Lbs -- -- -- -- -- -- 5990 --<br />

kN -- -- -- -- -- -- 26.65 --<br />

Lbs -- 3685 3220 3260 4190 2975 -- 545<br />

kN -- 16.39 14.32 14.50 18.64 13.23 -- 2.42<br />

Lbs -- -- -- -- -- -- 5990 --<br />

kN -- -- -- -- -- -- 26.65 --<br />

Lbs -- 4675 4205 4250 5315 3775 -- 545<br />

kN -- 20.80 18.71 18.91 23.64 16.79 -- 2.42<br />

Lbs -- -- -- -- -- -- 5990 --<br />

kN -- -- -- -- -- -- 26.65 --<br />

L<br />

H<br />

TF<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

W<br />

D<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 131<br />

<strong>USP</strong>2240-131


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Joist Size<br />

2-1/2 x 24<br />

2-1/2 x 26<br />

2-5/8 x 9-1/2<br />

2-5/8 x 11-7/8<br />

2-5/8 x 14<br />

<strong>USP</strong><br />

Stock No.<br />

TFI324<br />

MPH2524<br />

TFI326<br />

MPH2526<br />

Ref. No.<br />

HIT324,<br />

LBV2.56/24,<br />

WPI324<br />

-- --<br />

HIT326,<br />

LBV2.56/26,<br />

WPI326<br />

-- --<br />

-- --<br />

2-5/8 x 16 THO26160 -- --<br />

2-11/16<br />

x 9-1/4<br />

2-11/16<br />

x 9-1/2<br />

2-11/16<br />

x 11-1/4<br />

2-11/16<br />

x 11-7/8<br />

2-11/16 x 14<br />

2-11/16 x 16<br />

3 x 9-1/4<br />

3 x 9-1/2<br />

THO26950<br />

THO26118<br />

THO26140<br />

--<br />

Steel Gauge<br />

16<br />

x 12<br />

-- 16<br />

x 12<br />

-- 18<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header<br />

Joist<br />

Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

2-9/16<br />

2-1/2 24<br />

24 2-1/2 --<br />

26<br />

10d x 1-1/2<br />

2 16d duplex 2 10d x 1-1/2<br />

DF-L<br />

I-Joist 2<br />

<strong>EWP</strong> Top Mount Hanger Charts continued<br />

PHXU27925<br />

HLBH27925<br />

PHXU2795<br />

HLBH2795<br />

PHXU27112<br />

HLBH27112<br />

PHXU27118<br />

HLBH27118<br />

PHXU2714<br />

HLBH2714<br />

PHXU2716<br />

HLBH2716<br />

BPH31925<br />

PHXU31925<br />

-- --<br />

-- --<br />

HWU2.75/9.25<br />

GLTV2.75/9.25<br />

-- --<br />

GLTV2.75/9.5<br />

-- --<br />

GLTV2.75/11.25<br />

-- --<br />

GLTV2.75/11.88<br />

-- --<br />

GLTV2.75/14<br />

-- --<br />

GLTV2.75/16<br />

LBV3.12/9.25<br />

WP29.25-2<br />

MPH210-2 WM29.25-2<br />

THO15950-2<br />

LT2-159,<br />

MIT29.5-2<br />

BPH3195 LBV3.12/9.5<br />

PHXU3195<br />

MPH1595-2<br />

WP29.5-2<br />

WM29.5-2<br />

Web Stiffener Reqd.<br />

2-9/16<br />

2-1/2<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS:<br />

<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

2-1/2<br />

7<br />

2-1/2 --<br />

2<br />

3-3/4<br />

10 16d 2<br />

26 2-1/2 7 3-3/4 2 16d duplex 2 10d x 1-1/2<br />

2-11/16 9-1/2 2-3/8 -- 2 10 10d<br />

-- 16 2-11/16 11-7/8 2-3/8 --<br />

-- 18<br />

-- 18<br />

--<br />

x 7<br />

-- 7<br />

x 7<br />

-- 7<br />

x 7<br />

-- 7<br />

x 7<br />

-- 7<br />

x 7<br />

-- 7<br />

x 7<br />

x 12<br />

x<br />

2-11/16<br />

2-11/16<br />

2-3/4<br />

2-3/4<br />

2-3/4<br />

2-3/4<br />

2-3/4<br />

2-3/4<br />

2-3/4<br />

2-3/4<br />

3-1/8<br />

14<br />

2-3/8 --<br />

16 2-3/8 --<br />

7 2-3/4 9-1/4 3-1/4 10 2-1/2<br />

7<br />

x 12<br />

x 16<br />

x<br />

12<br />

x 7<br />

x 12<br />

2-3/4<br />

2-3/4<br />

2-3/4<br />

3-1/8<br />

3-1/8<br />

3-1/16<br />

3-1/8<br />

3-1/8<br />

3-1/8<br />

9-1/4<br />

9-1/2<br />

9-1/2<br />

11-1/4<br />

11-1/4<br />

11-7/8<br />

11-7/8<br />

14<br />

14<br />

16<br />

16<br />

9-1/4<br />

9-1/4<br />

9-1/4<br />

9-1/2<br />

9-1/2<br />

9-1/2<br />

9-1/2<br />

6<br />

3-1/4<br />

6<br />

3-1/4<br />

6<br />

3-1/4<br />

6<br />

3-1/4<br />

6<br />

3-1/4<br />

6<br />

3<br />

3-1/4<br />

2-1/2<br />

2-3/8<br />

3<br />

3-1/4<br />

2-1/2<br />

12<br />

10<br />

12<br />

10<br />

12<br />

10<br />

12<br />

10<br />

12<br />

10<br />

12<br />

--<br />

10<br />

7<br />

--<br />

--<br />

10<br />

7<br />

2<br />

2<br />

2<br />

2<br />

2-3/4<br />

2-1/2<br />

2-3/4<br />

2-1/2<br />

2-3/4<br />

2-1/2<br />

2-3/4<br />

2-1/2<br />

2-3/4<br />

2-1/2<br />

2-3/4<br />

2-3/32<br />

2-1/2<br />

3-3/4<br />

1-1/2<br />

2-3/32<br />

2-1/2<br />

3-3/4<br />

10 16d 2 10d x 1-1/2<br />

10 10d 2 10d x 1-1/2<br />

2<br />

10d x 1-1/2<br />

12 10d 2 10d x 1-1/2<br />

12 10d 2 10d x 1-1/2<br />

8 16d 6 10d x 1-1/2<br />

15 6 10d x 1-1/2<br />

8 16d 6 10d x 1-1/2<br />

15 6 10d x 1-1/2<br />

8 16d 6 10d x 1-1/2<br />

15 6 10d x 1-1/2<br />

8 16d 6 10d x 1-1/2<br />

15 6 10d x 1-1/2<br />

8 16d 6 10d x 1-1/2<br />

15 6 10d x 1-1/2<br />

8 16d 6 10d x 1-1/2<br />

15 6 10d x 1-1/2<br />

10 16d 4 10d<br />

8 16d 6<br />

10d x 1-1/2<br />

2 16d duplex 2 10d<br />

10 16d 6 10d<br />

10 16d 4 10d<br />

8 16d 6 10d x 1-1/2<br />

2 16d duplex 2<br />

10d<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs -- 4675 4205 4250 5315 3775 -- 545<br />

kN -- 20.80 18.71 18.91 23.64 16.79 -- 2.42<br />

Lbs -- -- -- -- -- -- 5990 --<br />

kN -- -- -- -- -- -- 26.65 --<br />

Lbs -- 4675 4205 4250 5315 3775 -- 545<br />

kN -- 20.80 18.71 18.91 23.64 16.79 -- 2.42<br />

Lbs -- -- -- -- -- -- 5990 --<br />

kN -- -- -- -- -- -- 26.65 --<br />

Lbs 2340 2340 2340 2340 2660 1890 -- 500<br />

kN 10.41 10.41 10.41 10.41 11.83 8.41 -- 2.22<br />

Lbs 2640 2640 2640 2640 3005 2130 -- 500<br />

kN 11.74 11.74 11.74 11.74 13.37 9.48 -- 2.22<br />

Lbs 3910 3910 3910 3910 4450 3160 -- 500<br />

kN 17.39 17.39 17.39 17.39 19.80 14.06 -- 2.22<br />

Lbs 3910 3910 3910 3910 4450 3160 -- 500<br />

kN 17.39 17.39 17.39 17.39 19.80 14.06 -- 2.22<br />

Lbs -- 8670 8330 8670 7610 5170 -- 1005<br />

kN -- 38.57 37.06 38.57 33.85 23.00 -- 4.47<br />

Lbs -- 14725 15180 13825 13825 12840 -- 1430<br />

kN -- 65.50 67.53 61.50 61.50 57.12 -- 6.36<br />

Lbs -- 8670 8330 8670 7610 5170 -- 1005<br />

kN -- 38.57 37.06 38.57 33.85 23.00 -- 4.47<br />

Lbs -- 14725 15180 13825 13825 12840 -- 1430<br />

kN -- 65.50 67.53 61.50 61.50 57.12 -- 6.36<br />

Lbs -- 8670 8330 8670 7610 5170 -- 1005<br />

kN -- 38.57 37.06 38.57 33.85 23.00 -- 4.47<br />

Lbs -- 14725 15180 13825 13825 12840 -- 1430<br />

kN -- 65.50 67.53 61.50 61.50 57.12 -- 6.36<br />

Lbs -- 8670 8330 8670 7610 5170 -- 1005<br />

kN -- 38.57 37.06 38.57 33.85 23.00 -- 4.47<br />

Lbs -- 14725 15180 13825 13825 12840 -- 1430<br />

kN -- 65.50 67.53 61.50 61.50 57.12 -- 6.36<br />

Lbs -- 8670 8330 8670 7610 5170 -- 1005<br />

kN -- 38.57 37.06 38.57 33.85 23.00 -- 4.47<br />

Lbs -- 14725 15180 13825 13825 12840 -- 1430<br />

kN -- 65.50 67.53 61.50 61.50 57.12 -- 6.36<br />

Lbs -- 8670 8330 8670 7610 5170 -- 1005<br />

kN -- 38.57 37.06 38.57 33.85 23.00 -- 4.47<br />

Lbs -- 14725 15180 13825 13825 12840 -- 1430<br />

kN -- 65.50 67.53 61.50 61.50 57.12 -- 6.36<br />

Lbs -- 5265 5055 5435 5055 4055 -- 780<br />

kN -- 23.42 22.49 24.18 22.49 18.04 -- 3.47<br />

Lbs -- 8670 8330 8670 7610 5170 -- 1005<br />

kN -- 38.57 37.06 38.57 33.85 23.00 -- 8670<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs 3785 3355 3585 3585 4180 2970 -- 2210<br />

kN 16.84 14.92 15.95 15.95 18.59 13.21 -- 9.83<br />

Lbs -- 5265 5055 5435 5055 4055 -- 780<br />

kN -- 23.42 22.49 24.18 22.49 18.04 -- 3.47<br />

Lbs -- 8670 8330 8670 7610 5170 -- 1005<br />

kN -- 38.57 37.06 38.57 33.85 23.00 -- 4.47<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

L<br />

H<br />

TF<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

W<br />

D<br />

continued on next page<br />

132<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Joist Size<br />

3 x 11-1/4<br />

3 x 11-7/8<br />

3 x 14<br />

3-1/2 x 9-1/4<br />

3-1/2 x 9-3/8<br />

<strong>USP</strong><br />

Stock No.<br />

BPH31112<br />

PHXU31112<br />

MPH15112-2<br />

THO15118-2<br />

BPH31118<br />

PHXU31118<br />

MPH15118-2<br />

BPH3114<br />

PHXU3114<br />

Ref. No.<br />

LT2-151188,<br />

MIT211.88-2<br />

LBV3.12/11.88<br />

WP211.88-2<br />

WM211.88-2<br />

LBV3.12/14<br />

-- --<br />

3-1/2 x 7-1/4 PHXU35725 WPU3.56/7.25<br />

THO35925<br />

BPH35925<br />

PHM35925<br />

PHXU35925<br />

HLBH35925<br />

MPH410<br />

THO35938<br />

LBV3.12/11.25<br />

WP211.25-2<br />

WM211.25-2<br />

LT35925<br />

<br />

LBV3.56/9.25<br />

WPI49.25<br />

HB3.56/9.25,<br />

HWI49.25,<br />

HWU3.56/9.25<br />

WM410<br />

-- --<br />

LT359375<br />

Web Stiffener Reqd.<br />

x<br />

Steel Gauge<br />

12<br />

x 7<br />

x 12<br />

x<br />

16<br />

x 12<br />

x 7<br />

x<br />

12<br />

x 12<br />

x 7<br />

x 7<br />

--<br />

x<br />

16<br />

x 12<br />

x 7/10<br />

7<br />

x 7<br />

-- 12<br />

-- 16<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header<br />

Joist<br />

Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

3-1/8<br />

3-1/8<br />

3-1/8<br />

3-1/16<br />

3-1/8<br />

3-1/8<br />

3-1/8<br />

3-1/8<br />

3-1/8<br />

3-9/16 7-1/4 3-1/4 10<br />

3-9/16<br />

3-9/16<br />

3-5/8<br />

3-9/16<br />

3-5/8<br />

3-9/16<br />

3-9/16<br />

11-1/4<br />

11-1/4<br />

11-1/4<br />

11-7/8<br />

11-7/8<br />

11-7/8<br />

11-7/8<br />

14<br />

14<br />

9-1/4<br />

9-1/4<br />

9-1/4<br />

9-1/4<br />

9-1/4<br />

9-1/4<br />

9-3/8<br />

3 -- 2-3/32<br />

10 16d 4 10d<br />

8 16d 6 10d x 1-1/2<br />

2 16d duplex 2 10d<br />

10 16d 6 10d<br />

4 10d<br />

2 16d duplex 2 10d<br />

16d 4 10d<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS:<br />

<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

New products or updated product information are designated in red font.<br />

3-1/4<br />

2-1/2<br />

2-3/8<br />

3-1/4<br />

2-3/8<br />

2-3/8<br />

2-3/8<br />

7<br />

--<br />

10<br />

--<br />

--<br />

7<br />

10<br />

12<br />

7<br />

--<br />

3-3/4<br />

1-1/2<br />

3 -- 2-3/32<br />

3-1/4<br />

2-1/2<br />

3<br />

2-1/2<br />

3-1/4<br />

6<br />

2-1/2<br />

10<br />

7<br />

--<br />

2-1/2<br />

3-3/4<br />

2-3/32<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

2-3/8<br />

3<br />

2-1/2<br />

3-1/8<br />

3-3/4<br />

2-9/16<br />

10 16d<br />

10 2-1/2 8 16d 6 10d x 1-1/2<br />

10<br />

8 16d 6 10d x 1-1/2<br />

8 16d 6 10d<br />

10<br />

10d 2 10d x 1-1/2<br />

10 16d 4 10d<br />

2<br />

16d 2 10d<br />

8 16d 6 10d<br />

15<br />

6 16d<br />

2 16d duplex 2 10d<br />

10<br />

10d 2 10d x 1-1/2<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs -- 5265 5055 5435 5055 4055 -- 780<br />

kN -- 23.42 22.49 24.18 22.49 18.04 -- 3.47<br />

Lbs -- 8670 8330 8670 7610 5170 -- 1005<br />

kN -- 38.57 37.06 38.57 33.85 23.00 -- 4.47<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs 3785 3355 3550 3550 4150 2945 -- 2210<br />

kN 16.84 14.92 15.79 15.79 18.46 13.10 -- 9.83<br />

Lbs -- 5265 5055 5435 5055 4055 -- 780<br />

kN -- 23.42 22.49 24.18 22.49 18.04 -- 3.47<br />

Lbs -- 8670 8330 8670 7610 5170 -- 1005<br />

kN -- 38.57 37.06 38.57 33.85 23.00 -- 4.47<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs -- 5265 5055 5435 5055 4055 -- 780<br />

kN -- 23.42 22.49 24.18 22.49 18.04 -- 3.47<br />

Lbs -- 8670 8330 8670 7610 5170 -- 1005<br />

kN -- 38.57 37.06 38.57 33.85 23.00 -- 4.47<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1290<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.74<br />

Lbs 2950 2950 2950 2950 2975 2115 -- 500<br />

kN 13.12 13.12 13.12 13.12 13.23 9.41 -- 2.22<br />

Lbs -- 5300 5055 5435 5055 4725 -- 830<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 3.69<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1290<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs 2950 2950 2950 2950 2975 2115 -- 500<br />

kN 13.12 13.12 13.12 13.12 13.23 9.41 -- 2.22<br />

L<br />

H<br />

TF<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

W<br />

D<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 133<br />

<strong>USP</strong>2240-131


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Joist Size<br />

3-1/2 x 9-1/2<br />

3-1/2 x 11-1/4<br />

3-1/2 x 11-7/8<br />

3-1/2 x 12<br />

<strong>USP</strong><br />

Stock No.<br />

THO35950<br />

THO17950-2<br />

BPH3595<br />

PHM3595<br />

PHXU3595<br />

HLBH3595<br />

MPH1795-2<br />

THO35112<br />

BPH35112<br />

PHXU35112<br />

HLBH35112<br />

MPH412<br />

THO35118<br />

THO35120<br />

BPH3512<br />

PHXU3512<br />

HLBH3512<br />

MPH3512<br />

Ref. No.<br />

LT359<br />

LT351188<br />

THO17118-2 MIT411.88<br />

BPH35118<br />

<br />

LBV3.56/11.88<br />

PHM35118<br />

PHXU35118<br />

HLBH35118<br />

MPH17118-2<br />

MIT49.5<br />

LBV3.56/9.5<br />

WPI49.5<br />

GLTV3.59,<br />

HB3.56/9.5,<br />

HWI49.5,<br />

HWU3.56/9.5<br />

HGLTV3.59<br />

WM3.56/9.5<br />

LT351125<br />

<br />

LBV3.56/11.25<br />

GLTV3.56/11.25,<br />

HB3.56/11.25,<br />

HWI411.25,<br />

HWU3.56/11.25,<br />

WPI411.25<br />

HGLTV3.56/11.25<br />

WM412<br />

WPI411.88<br />

GLTV3.511,<br />

HB3.56/11.88,<br />

HWI411.88,<br />

HWU3.56/11.88,<br />

WPU3.56/11.88<br />

HGLTV3.511<br />

WM3.56/11.88<br />

-- --<br />

HWI412,<br />

LBV3.56/12<br />

GLTV3.512,<br />

HB3.56/12<br />

HGLTV3.512<br />

WMI412<br />

Web Stiffener Reqd.<br />

Steel Gauge<br />

-- 16<br />

x 16<br />

x 12<br />

x<br />

x<br />

x<br />

--<br />

--<br />

x<br />

x<br />

7/10<br />

7<br />

7<br />

12<br />

16<br />

12<br />

x 7<br />

x 7<br />

-- 12<br />

-- 18<br />

x 16<br />

12<br />

x 7/10<br />

x 7<br />

x 7<br />

-- 12<br />

-- 18<br />

x 12<br />

x 7<br />

x 7<br />

-- 12<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header<br />

Joist<br />

Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

3-9/16 9-1/2 2-3/8 -- 2-7/16 10 10d 2 10d x 1-1/2<br />

3-9/16<br />

3-9/16<br />

3-5/8<br />

3-9/16<br />

3-5/8<br />

3-5/8<br />

3-9/16<br />

3-9/16<br />

3-9/16 11-1/4<br />

3-5/8<br />

3-9/16<br />

3-9/16<br />

3-9/16<br />

3-9/16<br />

3-5/8<br />

3-9/16<br />

3-5/8<br />

3-5/8<br />

3-9/16<br />

3-9/16<br />

3-9/16<br />

3-5/8<br />

9-1/2<br />

9-1/2<br />

9-1/2<br />

9-1/2<br />

9-1/2<br />

9-1/2<br />

11-1/4<br />

11-1/4<br />

11-1/4<br />

11-1/4<br />

11-7/8<br />

11-7/8<br />

11-7/8<br />

11-7/8<br />

11-7/8<br />

12<br />

12<br />

12<br />

12<br />

3-1/2 12<br />

11-7/8 6 12<br />

11-7/8<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS:<br />

<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

2-3/8<br />

2-3/8<br />

2-1/2<br />

3-1/4<br />

6<br />

2-1/2<br />

2-3/8<br />

2-3/8<br />

3-1/4<br />

6<br />

2-1/2<br />

2-3/8<br />

2-3/8<br />

2-3/8<br />

2-1/2<br />

3-1/4<br />

2-1/2<br />

2-3/8<br />

2-3/4<br />

3-1/4<br />

6<br />

2-1/2<br />

-- 1-9/16<br />

--<br />

7<br />

10<br />

12<br />

7<br />

--<br />

--<br />

10<br />

12<br />

7<br />

--<br />

--<br />

--<br />

7<br />

10<br />

7<br />

--<br />

--<br />

10<br />

12<br />

7<br />

2-3/8<br />

3<br />

2-1/2<br />

3-1/8<br />

3-3/4<br />

2-1/2<br />

2-3/8<br />

2-1/2<br />

3-1/8<br />

3-3/4<br />

2-1/2<br />

1-9/16<br />

2-3/8<br />

3<br />

2.5<br />

3-1/8<br />

3-3/4<br />

2-1/2<br />

2-1/32<br />

2-1/2<br />

3-1/8<br />

3-3/4<br />

10 16d 6 10d<br />

10 16d 4 10d<br />

2 16d 2 10d<br />

8 16d 6 10d<br />

15 6 16d<br />

2 16d duplex 2 10d<br />

10 10d 2 10d x 1-1/2<br />

10 16d 4<br />

10 10d<br />

10 16d 6<br />

8 16d<br />

2 10d x 1-1/2<br />

10d<br />

6 10d<br />

15 6 16d<br />

2 16d duplex 2<br />

10d<br />

8 16d 6 10d<br />

15 6 16d<br />

2 16d duplex 2 10d<br />

10 10d 2 10d x 1-1/2<br />

10<br />

10<br />

16d 6 10d<br />

16d 4 10d<br />

2 16d 2<br />

10d<br />

8 16d 6 10d<br />

15 6 16d<br />

2 16d duplex 2 10d<br />

10d<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs 2950 2950 2950 2950 2975 2115 -- 500<br />

kN 13.12 13.12 13.12 13.12 13.23 9.41 -- 2.22<br />

Lbs 3785 3355 3680 3680 4370 3100 -- 2210<br />

kN 16.84 14.92 16.37 16.37 19.44 13.79 -- 9.83<br />

Lbs -- 5300 5055 5435 5055 4725 -- 830<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 3.69<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1290<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs 2950 2950 2950 2950 2975 2115 -- 500<br />

kN 13.12 13.12 13.12 13.12 13.23 9.41 -- 2.22<br />

Lbs -- 5300 5055 5435 5055 4725 -- 830<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 3.69<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1290<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs 2535 2950 2950 2950 2975 2115 -- 500<br />

kN 11.28 13.12 13.12 13.12 13.23 9.41 -- 2.22<br />

Lbs 3785 3355 3390 3390 4820 3425 -- 2210<br />

kN 16.84 14.92 15.08 15.08 21.44 15.24 -- 9.83<br />

Lbs -- 5300 5055 5435 5055 4725 -- 830<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 3.69<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1290<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs 2950 2950 2950 2950 2975 2115 -- 500<br />

kN 13.12 13.12 13.12 13.12 13.23 9.41 -- 2.22<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1335<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.94<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

L<br />

H<br />

TF<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

W<br />

D<br />

continued on next page<br />

134<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Joist Size<br />

3-1/2 x 13<br />

3-1/2 x 14<br />

3-1/2 x 16<br />

3-1/2 x 18<br />

<strong>USP</strong><br />

Stock No.<br />

THO35130<br />

THO35140<br />

TFI414<br />

BPH3514<br />

PHM3514<br />

PHXU3514<br />

HLBH3514<br />

MPH3514<br />

THO35160<br />

TFI416<br />

BPH3516<br />

PHM3516<br />

PHXU3516<br />

HLBH3516<br />

MPH3516<br />

TFI418<br />

BPH3518<br />

PHM3518<br />

PHXU3518<br />

HLBH3518<br />

MPH3518<br />

Ref. No.<br />

LT3513<br />

LT3514<br />

MIT414<br />

B3.56/14,<br />

<br />

LBV3.56/14<br />

WPI414<br />

GLTV3.514,<br />

HB3.56/14,<br />

HWI414,<br />

HWU3.56/14,<br />

WPU3.56/14<br />

HGLTV3.514<br />

WMI414<br />

LT3516<br />

MIT416<br />

B3.56/16,<br />

<br />

LBV3.56/16<br />

WPI416<br />

GLTV3.516,<br />

HB3.56/16,<br />

HWI416,<br />

HWU3.56/16,<br />

WPU3.56/16<br />

HGLTV3.516<br />

WMI416<br />

HIT418,<br />

MIT418<br />

LBV3.56/18<br />

WPI418<br />

GLTV3.518,<br />

HB3.56/18,<br />

HWI418,<br />

HWU3.56/18,<br />

WPU3.56/18<br />

HGLTV3.518<br />

WMI418<br />

Web Stiffener Reqd.<br />

Steel Gauge<br />

-- 18<br />

-- 18<br />

-- 16<br />

x 12<br />

x 7/10<br />

x 7<br />

-- 18<br />

-- 16<br />

x 12<br />

x 7/10<br />

-- 16<br />

x 12<br />

x 7/10<br />

x 7<br />

x 7<br />

x 12<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header Joist Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

3-9/16 13 2-3/8 -- 2-1/2 10 10d 2 10d x 1-1/2<br />

3-9/16 18 2-1/2 -- 2-1/8<br />

3-9/16<br />

3-5/8<br />

3-9/16<br />

3-5/8<br />

18<br />

18<br />

18<br />

8 16d 6<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS:<br />

<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

2-1/2<br />

3-1/4<br />

3-1/2 18 2-1/2<br />

6<br />

7<br />

10<br />

12<br />

7<br />

2-1/2<br />

3-1/8<br />

3-3/4<br />

6 16d 2<br />

10d x 1-1/2<br />

18 2-3/4 -- 2-1/32 10 16d 6 10d<br />

3<br />

10 16d<br />

x 7 3-9/16 14 3-1/4 10 2.5 8 16d 6 10d<br />

-- 12<br />

x 7<br />

x 7<br />

-- 12<br />

3-9/16<br />

3-9/16<br />

3-9/16<br />

3-5/8<br />

3-5/8<br />

3-1/2<br />

3-9/16<br />

3-9/16<br />

3-9/16<br />

3-5/8<br />

3-9/16<br />

3-5/8<br />

3-1/2<br />

14<br />

14<br />

14<br />

14<br />

14<br />

14<br />

16<br />

16<br />

16<br />

16<br />

16<br />

16<br />

2-3/8<br />

2-1/2<br />

2-3/4<br />

2-1/2<br />

6<br />

2-1/2<br />

2-3/8<br />

2-3/4<br />

2-1/2<br />

3-1/4<br />

6<br />

2-1/2<br />

--<br />

--<br />

--<br />

7<br />

12<br />

7<br />

--<br />

16 2-1/2 --<br />

--<br />

7<br />

10<br />

12<br />

7<br />

2-1/2<br />

2-1/8<br />

2-1/32<br />

3<br />

3-1/8<br />

3-3/4<br />

2-1/2<br />

2-1/8<br />

2-1/32<br />

3<br />

2-1/2<br />

3-1/8<br />

3-3/4<br />

12 10d 2 10d x 1-1/2<br />

6 16d 2 10d x 1-1/2<br />

2 16d 2<br />

12 10d<br />

10d<br />

2 16d duplex 2 10d<br />

15 6 16d<br />

2 16d duplex<br />

2 10d x 1-1/2<br />

6 16d 2 10d x 1-1/2<br />

10 16d<br />

6 10d<br />

2 16d 2 10d<br />

8 16d<br />

6 10d<br />

15 6 16d<br />

6 10d<br />

2 10d<br />

2 16d 2 10d<br />

10d<br />

15 6 16d<br />

2 16d duplex 2 10d<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs 2950 2950 2950 2950 2975 2115 -- 500<br />

kN 13.12 13.12 13.12 13.12 13.23 9.41 -- 2.22<br />

Lbs 3910 3910 3910 3910 4450 3160 -- 500<br />

kN 17.39 17.39 17.39 17.39 19.80 14.06 -- 2.22<br />

Lbs -- 3685 3220 3260 4190 2975 -- 545<br />

kN -- 16.39 14.32 14.50 18.64 13.23 -- 2.42<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1290<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs 3910 3910 3910 3910 4450 3160 -- 500<br />

kN 17.39 17.39 17.39 17.39 19.80 14.06 -- 2.22<br />

Lbs -- 3685 3220 3260 4190 2975 -- 545<br />

kN -- 16.39 14.32 14.50 18.64 13.23 -- 2.42<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1290<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs -- 3685 3220 3260 4190 2975 -- 545<br />

kN -- 16.39 14.32 14.50 18.64 13.23 -- 2.42<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1290<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

W<br />

L<br />

H<br />

D<br />

TF<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 135<br />

<strong>USP</strong>2240-131


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Joist Size<br />

3-1/2 x 20<br />

3-1/2 x 22<br />

3-1/2 x 24<br />

3-1/2 x 26<br />

3-1/2 x 28<br />

3-1/2 x 30<br />

3-1/2 x 32<br />

<strong>USP</strong><br />

Stock No. Ref. No.<br />

TFI420 MIT420<br />

BPH3520<br />

HIT420,<br />

LBV3.56/20<br />

PHM3520 WPI420<br />

HB3.56/20,<br />

PHXU3520 HWI420,<br />

WPU3.56/20<br />

HLBH3520 -- --<br />

MPH3520<br />

TFI422<br />

BPH3522<br />

PHM3522<br />

PHXU3522<br />

TFI424<br />

BPH3524<br />

PHM3524<br />

PHXU3524<br />

TFI426<br />

BPH3526<br />

PHM3526<br />

PHXU3526<br />

BPH3528<br />

PHM3528<br />

PHXU3528<br />

BPH3530<br />

PHM3530<br />

PHXU3530<br />

WMI420<br />

HIT422<br />

HIT3522,<br />

LBV3.56/22<br />

HWI422,<br />

WPI422<br />

HB3.56/22<br />

WPU3.56/22<br />

HIT424,<br />

LBV3.56/24<br />

-- --<br />

HWI424,<br />

WPI424<br />

Web Stiffener Reqd.<br />

Steel Gauge<br />

x 12<br />

--<br />

16<br />

12<br />

x 7/10<br />

7<br />

-- 16<br />

x 12<br />

x 7/10<br />

HB3.56/24,<br />

WPU3.56/24<br />

x 7<br />

HIT426 -- 16<br />

LBV3.56/26<br />

HWI426,<br />

WPI426<br />

HB3.56/26,<br />

WPU3.56/26<br />

LBV3.56/28<br />

HWI428,<br />

WPI428<br />

HB3.56/28,<br />

WPU3.56/28<br />

LBV3.56/30<br />

HWI430,<br />

WPI430<br />

HB3.56/30<br />

BPH3532 -- --<br />

PHM3532<br />

HWI432,<br />

WPI432<br />

PHXU3532 -- --<br />

--<br />

x<br />

x<br />

16<br />

x 12<br />

x 7/10<br />

x<br />

x<br />

7<br />

7<br />

x 12<br />

x 7/10<br />

x 7<br />

x 12<br />

x 7/10<br />

x 7<br />

x 12<br />

x 7/10<br />

x 7<br />

x 12<br />

x 7/10<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header Joist Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

3-9/16<br />

3-9/16<br />

3-5/8<br />

3-9/16<br />

3-5/8<br />

3-1/2<br />

3-9/16<br />

3-9/16<br />

3-9/16<br />

22<br />

22<br />

24<br />

2-1/2<br />

2-3/4<br />

3-5/8 22 2-1/2<br />

3-9/16<br />

20<br />

20<br />

20<br />

20<br />

20<br />

20<br />

22<br />

2-1/2<br />

2-3/4<br />

2-1/2<br />

3-1/4<br />

3-1/4<br />

2-1/2<br />

3-9/16 24 2-3/4 -- 2-1/32<br />

3-5/8 24 2-1/2<br />

3-9/16 24 3-1/4 10<br />

3-9/16<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS:<br />

<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

6<br />

2-1/2<br />

--<br />

--<br />

7<br />

10<br />

12<br />

7<br />

--<br />

--<br />

7<br />

10<br />

--<br />

7<br />

2-1/8<br />

2-1/32<br />

3<br />

2-1/2<br />

3-1/8<br />

3-3/4<br />

2-1/8<br />

2-1/32<br />

3<br />

2-1/2<br />

2-1/8<br />

3<br />

2-1/2<br />

3-9/16 26 2-3/4 -- 2-1/32<br />

3-5/8<br />

3-9/16<br />

3-9/16<br />

3-5/8<br />

3-9/16<br />

3-9/16<br />

3-5/8<br />

26<br />

26<br />

26<br />

28<br />

28<br />

28<br />

30<br />

30<br />

2-1/2<br />

2-1/2<br />

3-1/4<br />

2-3/4<br />

2-1/2<br />

3-1/4<br />

2-3/4<br />

2-1/2<br />

--<br />

7<br />

10<br />

3<br />

-- 2-1/32<br />

7<br />

10<br />

--<br />

7<br />

2-1/8<br />

2-1/2<br />

3<br />

2-1/2<br />

2-1/32<br />

3<br />

6 16d 2 10d x 1-1/2<br />

10<br />

8<br />

2<br />

10<br />

16d 6 10d<br />

2 16d 2 10d<br />

16d 6 10d<br />

15 6<br />

16d 6 10d<br />

2 16d 2<br />

16d<br />

16d duplex 2 10d<br />

10 16d 2 10d x 1-1/2<br />

10d<br />

8 16d 6 10d<br />

10 16d 2 10d x 1-1/2<br />

10 16d 6 10d<br />

2 16d 2 10d<br />

8 16d 6 10d<br />

10 16d<br />

2 10d x 1-1/2<br />

10 16d 6 10d<br />

2 16d<br />

2 10d<br />

8 16d 6 10d<br />

10 16d<br />

6 10d<br />

2 16d 2 10d<br />

8 16d 6 10d<br />

10 16d<br />

2 16d<br />

3-9/16 30 3-1/4 10 2-1/2 8 16d 6 10d<br />

3-9/16 32 2-3/4 -- 2-1/32 10 16d<br />

3-5/8<br />

32<br />

2-1/2<br />

7<br />

6<br />

10d<br />

2 10d<br />

x 7 3-9/16 32 3-1/4 10 2-1/2 8 16d 6 10d<br />

3<br />

6 10d<br />

2 16d 2 10d<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

L<br />

DF-L 115%<br />

Lbs -- 3685 3220 3260 4190 2975 -- 545<br />

kN -- 16.39 14.32 14.50 18.64 13.23 -- 2.42<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1290<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs -- 4675 4205 4250 5315 3775 -- 545<br />

kN -- 20.80 18.71 18.91 23.64 16.79 -- 2.42<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1335<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.94<br />

Lbs -- 4675 4205 4250 5315 3775 -- 545<br />

kN -- 20.80 18.71 18.91 23.64 16.79 -- 2.42<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1335<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.94<br />

Lbs -- 4675 4205 4250 5315 3775 -- 545<br />

kN -- 20.80 18.71 18.91 23.64 16.79 -- 2.42<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1335<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.94<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1335<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.94<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1335<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.94<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs -- 9575 8330 9245 7610 5170 -- 1335<br />

kN -- 42.59 37.06 41.13 33.85 23.00 -- 5.94<br />

H<br />

TF<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

W<br />

D<br />

continued on next page<br />

136<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Joist Size<br />

4 - 4-3/16<br />

x 9-1/2<br />

4 - 4-3/16<br />

x 11-7/8<br />

4 - 4-3/16<br />

x 14<br />

4 - 4-3/16<br />

x 16<br />

4-1/2 - 4-5/8<br />

x 9-1/2<br />

4-1/2 - 4-5/8<br />

x 11-7/8<br />

4-1/2 - 4-5/8<br />

x 14<br />

4-1/2 - 4-5/8<br />

x 16<br />

4-1/2 - 4-5/8<br />

x 18<br />

<strong>USP</strong><br />

Stock No. Ref. No.<br />

LBV4.12/9.5,<br />

THO20950-2 LBV4.28/9.5,<br />

MIT4.28/9.5<br />

PHM4295<br />

THO20118-2<br />

PHM42118<br />

THO20140-2<br />

PHM4214<br />

THO20160-2<br />

PHM4216<br />

THO23950-2<br />

PHM2395-2<br />

THO23118-2<br />

PHM23118-2<br />

MPH23118-2<br />

THO23140-2<br />

MPH2314-2<br />

THO23160-2<br />

PHM2316-2<br />

MPH2316-2<br />

-- --<br />

LBV4.12/11.88,<br />

LBV4.28/11.88,<br />

MIT4.28/11.88<br />

-- --<br />

LBV4.12/14,<br />

LBV4.28/14,<br />

MIT4.28/14<br />

-- --<br />

LBV4.12/16,<br />

LBV4.28/16<br />

-- --<br />

LBV4.75/9.5,<br />

MIT359.5-2<br />

WP359.5-2<br />

LBV4.75/11.88,<br />

MIT3511.88-2<br />

WP3511.88-2<br />

WM3511.88-2<br />

LBV4.75/14,<br />

MIT3514-2<br />

WM3514-2<br />

Web Stiffener Reqd.<br />

Steel Gauge<br />

x 16<br />

x 7/10<br />

x<br />

x 7/10<br />

x 12<br />

x 7/10<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header Joist Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

4-3/16<br />

4-3/16<br />

4-3/16<br />

4-3/16<br />

4-3/16<br />

4-3/16<br />

14<br />

x 12 4-3/4 9-1/2<br />

x<br />

16<br />

x 12<br />

x 7/10<br />

x 7/10<br />

12<br />

x 7/10<br />

x 12<br />

x 12<br />

x 12<br />

LBV4.75/16 x 12<br />

WP3516-2<br />

WM3516-2<br />

x 7/10<br />

x 12<br />

4-3/16<br />

4-3/16<br />

4-3/4<br />

4-3/4<br />

4-3/4<br />

4-5/8<br />

4-3/4<br />

4-5/8<br />

4-3/4<br />

4-3/4<br />

4-5/8<br />

9-1/2<br />

9-1/2<br />

11-7/8<br />

11-7/8<br />

14<br />

16<br />

16<br />

9-1/2<br />

11-7/8<br />

11-7/8<br />

11-7/8<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS:<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

3<br />

2-1/2<br />

3<br />

2-1/2<br />

3<br />

2-1/2<br />

3<br />

2-1/2<br />

3<br />

2-1/2<br />

3<br />

2-1/2<br />

2-1/2<br />

--<br />

7<br />

--<br />

7<br />

--<br />

7<br />

--<br />

7<br />

--<br />

7<br />

--<br />

7<br />

7<br />

2<br />

3<br />

2<br />

3<br />

1-15/16<br />

3<br />

1-15/16<br />

3<br />

2<br />

3<br />

2-1/8<br />

3<br />

3-3/4<br />

THO23180-2 LBV4.75/18 x 12 4-3/4 18 3 -- 2-1/8<br />

PHM2318-2<br />

MPH2318-2<br />

WP3518-2<br />

WM3518-2<br />

x<br />

7/10<br />

x 12<br />

4-3/4<br />

4-5/8<br />

14<br />

14<br />

16<br />

16<br />

16<br />

18<br />

18<br />

3<br />

2-1/2<br />

3<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

--<br />

7<br />

--<br />

7<br />

7<br />

7<br />

2-1/8<br />

3-3/4<br />

2-1/8<br />

3<br />

3-3/4<br />

3<br />

10 16d 6 10d<br />

2 16d 2 10d<br />

10 16d 6 10d<br />

2<br />

10<br />

16d 2 10d<br />

10 16d 6 10d<br />

2 16d<br />

16d<br />

2 10d<br />

2 16d 2 10d<br />

10 16d<br />

6 10d<br />

2 16d 2 10d<br />

2 16d duplex<br />

6 10d<br />

2 16d 2 10d<br />

10 16d 6 10d<br />

12<br />

16d<br />

2 16d duplex<br />

12 16d<br />

2 16d<br />

2 10d<br />

10d<br />

2 16d duplex 2 10d<br />

14<br />

6 10d<br />

2 10d<br />

6 10d<br />

2<br />

16d 6<br />

10d<br />

2 16d 2 10d<br />

2-1/2 7 3-3/4 2 16d duplex 2 10d<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs 3785 3355 3840 3840 4370 3100 -- 2210<br />

kN 16.84 14.92 17.08 17.08 19.44 13.79 -- 9.83<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs 3785 3355 3890 3890 4820 3425 -- 2210<br />

kN 16.84 14.92 17.30 17.30 21.44 15.24 -- 9.83<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs 3785 3355 5330 5330 6060 4305 -- 2210<br />

kN 16.84 14.92 23.71 23.71 26.96 19.15 -- 9.83<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs 3785 3355 5330 5330 6060 4305 -- 2210<br />

kN 16.84 14.92 23.71 23.71 26.96 19.15 -- 9.83<br />

Lbs -- 5395 5140 4435 4685 4685 -- --<br />

kN -- 24.00 22.86 19.73 20.84 20.84 -- --<br />

Lbs 3785 5090 5235 5235 6005 4265 -- 2210<br />

kN 16.84 22.64 23.29 23.29 26.71 18.97 -- 9.83<br />

Lbs -- 5395 4685 4270 4685 4685 -- --<br />

kN -- 24.00 20.84 18.99 20.84 20.84 -- --<br />

Lbs 3785 5090 5280 5280 6005 4265 -- 2210<br />

kN 16.84 22.64 23.49 23.49 26.71 18.97 -- 9.83<br />

Lbs -- 5395 4685 4270 4685 4685 -- --<br />

kN -- 24.00 20.84 18.99 20.84 20.84 -- --<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs 3785 5090 6345 6345 7290 5175 -- 2210<br />

kN 16.84 22.64 28.23 28.23 32.43 23.02 -- 9.83<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs 3785 5090 6345 6345 7290 5175 -- 2210<br />

kN 16.84 22.64 28.23 28.23 32.43 23.02 -- 9.83<br />

Lbs -- 5395 4685 4270 4685 4685 -- --<br />

kN -- 24.00 20.84 18.99 20.84 20.84 -- --<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs 3785 5090 6745 6745 9500 6745 -- 2210<br />

kN 16.84 22.64 30.00 30.00 42.26 30.00 -- 9.83<br />

Lbs -- 5395 4685 4270 4685 4685 -- --<br />

kN -- 24.00 20.84 18.99 20.84 20.84 -- --<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

L<br />

H<br />

TF<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

W<br />

D<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 137<br />

<strong>USP</strong>2240-131


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Joist Size<br />

4-1/2 - 4-5/8<br />

x 20<br />

5 x 9-1/4<br />

5 x 9-1/2<br />

5 x 11-1/4<br />

5 x 11-7/8<br />

5 x 14<br />

5 x 16<br />

5 x 18<br />

5 x 20<br />

5 x 22<br />

5 x 24<br />

5 x 26<br />

<strong>USP</strong><br />

Stock No.<br />

THO23200-2<br />

PHM2320-2<br />

MPH2320-2<br />

THO25925-2<br />

THO25950-2<br />

PHM2595-2<br />

THO25112-2<br />

THO25118-2<br />

THO25140-2<br />

PHM2514-2<br />

THO25160-2<br />

PHM2516-2<br />

THO25180-2<br />

PHM2518-2<br />

THO25200-2<br />

PHM2520-2<br />

Ref. No.<br />

LBV4.75/20<br />

WP3520-2<br />

WM3520-2<br />

LBV5.12/9.25<br />

MIT39.5-2,<br />

LBV5.12/9.5<br />

WPI39.5-2<br />

LBV5.12/11.25<br />

LBV5.12/11.88,<br />

MIT311.88-2<br />

MIT314-2,<br />

LBV5.12/14<br />

WPI314-2<br />

MIT5.12/16,<br />

LBV5.12/16<br />

WPI316-2<br />

B5.12/18<br />

WPI318-2<br />

B5.12/20<br />

WPI320-2<br />

Web Stiffener Reqd.<br />

x<br />

Steel Gauge<br />

12<br />

x 7/10<br />

x 12<br />

x 12<br />

x 12<br />

x 7/10<br />

x 7/10<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header Joist Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

4-3/4 20 3 -- 2-1/8 14 16d 6 10d<br />

4-3/4<br />

4-5/8<br />

5-1/8<br />

20<br />

20<br />

5-1/8 9-1/4<br />

5-1/8<br />

5-1/8<br />

5-1/8<br />

9-1/2<br />

9-1/2<br />

x 12 5-1/8 11-1/4<br />

x 12<br />

x 12<br />

x<br />

7/10<br />

x 12<br />

x 12<br />

x 7/10<br />

x 12<br />

x<br />

7/10<br />

5-1/8 11-7/8<br />

5-1/8<br />

5-1/8<br />

5-1/8<br />

5-1/8<br />

14<br />

14<br />

16<br />

16<br />

18<br />

5-1/8 20<br />

5-1/8<br />

20<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

New products or updated product information are designated in red font.<br />

2-1/2<br />

2-1/2<br />

3<br />

3<br />

3<br />

2-1/2<br />

3<br />

2-1/2<br />

7<br />

7<br />

--<br />

3 --<br />

2-1/2<br />

3<br />

3<br />

2-1/2<br />

3<br />

2-1/2<br />

5-1/4 x 7-1/4 BPH55725 HB5.50/7.25 x 10 5-9/16 7-1/4 2-1/4 --<br />

GLTV5.50/9.25,<br />

PHXU55925 HB5.50/9.25, x 7 5-1/2 9-1/4 3-1/4 11-1/2<br />

5-1/4 x 9-1/4<br />

HWU5.50/9.25<br />

HLBH55925 -- -- x 7 5-9/16 9-1/4 6 12<br />

5-1/4 x 9-1/2<br />

PHM2522-2<br />

PHM2524-2<br />

PHM2526-2<br />

BPH5595<br />

PHM5595<br />

PHXU5595<br />

HLBH5595<br />

MPH5595<br />

WPI322-2<br />

WPI324-2<br />

WPI326-2<br />

-- --<br />

WP5.50/9.5<br />

GLTV5.59,<br />

HB5.50/9.5,<br />

HWU5.50/9.5<br />

HGLTV5.59<br />

WM5.50/9.5<br />

x 7/10<br />

x 7/10<br />

x 7/10<br />

x 12<br />

x 7/10<br />

x<br />

7<br />

x 7<br />

x 12<br />

5-1/8<br />

5-1/8<br />

5-1/8<br />

5-9/16<br />

5-5/8<br />

5-1/2<br />

5-9/16<br />

5-5/8<br />

18<br />

22<br />

24<br />

26<br />

9-1/2<br />

9-1/2<br />

9-1/2<br />

9-1/2<br />

9-1/2<br />

2-1/2<br />

2-1/2<br />

2-1/2<br />

3<br />

2-1/2<br />

3-1/4<br />

6<br />

2-1/2<br />

7<br />

--<br />

--<br />

--<br />

7<br />

--<br />

7<br />

--<br />

7<br />

--<br />

7<br />

7<br />

7<br />

7<br />

--<br />

7<br />

11.5<br />

12<br />

3<br />

3-3/4<br />

2-11/16<br />

2-1/8<br />

3<br />

2-1/8<br />

2-1/8<br />

2-1/8<br />

3<br />

2-1/8<br />

3<br />

2-1/8<br />

3<br />

2-1/8<br />

3<br />

3<br />

3<br />

3<br />

2 16d 2<br />

6<br />

6<br />

2<br />

10d<br />

2 16d duplex 2 10d<br />

10 16d 6 10d<br />

10 16d<br />

2<br />

10<br />

10<br />

16d<br />

16d<br />

16d<br />

12 16d<br />

2 16d<br />

12 16d<br />

10d<br />

2 10d<br />

6 10d<br />

10d<br />

6 10d<br />

10d<br />

6 10d<br />

2 16d 2 10d<br />

14 16d 6<br />

14 16d<br />

2 16d 2<br />

10d<br />

2 16d 2 10d<br />

2 16d<br />

2 16d<br />

2 16d<br />

2-1/2 10 16d 6<br />

2-1/2<br />

3-1/8<br />

2-1/6<br />

3<br />

2-1/2<br />

3-1/8<br />

7 3-3/4<br />

8 16d 6<br />

15 <br />

10 16d 4<br />

8 16d 6<br />

15 6<br />

2 16d duplex 2<br />

6 10d<br />

10d<br />

2 10d<br />

2 10d<br />

2 10d<br />

10d<br />

10d<br />

6 16d<br />

10d<br />

2 16d 2 10d<br />

10d<br />

16d<br />

10d<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs 3785 5090 6745 6745 9500 6745 -- 2210<br />

kN 16.84 22.64 30.00 30.00 42.26 30.00 -- 9.83<br />

Lbs -- 5395 4685 4270 4685 4685 -- --<br />

kN -- 24.00 20.84 18.99 20.84 20.84 -- --<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs 3785 5090 5280 5280 6005 4265 -- 2210<br />

kN 16.84 22.64 23.49 23.49 26.71 18.97 -- 9.83<br />

Lbs 3785 5090 5280 5280 6005 4265 -- 2210<br />

kN 16.84 22.64 23.49 23.49 26.71 18.97 -- 9.83<br />

Lbs -- 5395 4685 4270 4685 4685 -- --<br />

kN -- 24.00 20.84 18.99 20.84 20.84 -- --<br />

Lbs 3785 5090 5280 5280 6005 4265 -- 2210<br />

kN 16.84 22.64 23.49 23.49 26.71 18.97 -- 9.83<br />

Lbs 3785 5090 5280 5280 6005 4265 -- 2210<br />

kN 16.84 22.64 23.49 23.49 26.71 18.97 -- 9.83<br />

Lbs 3785 5090 6345 6345 6645 4715 -- 2210<br />

kN 16.84 22.64 28.23 28.23 29.56 20.97 -- 9.83<br />

Lbs -- 5395 4685 4270 4685 4685 -- --<br />

kN -- 24.00 20.84 18.99 20.84 20.84 -- --<br />

Lbs 3785 5090 6345 6345 6645 4715 -- 2210<br />

kN 16.84 22.64 28.23 28.23 29.56 20.97 -- 9.83<br />

Lbs -- 5395 4685 4270 4685 4685 -- --<br />

kN -- 24.00 20.84 18.99 20.84 20.84 -- --<br />

Lbs 3785 5090 6745 6745 9500 6745 -- 2210<br />

kN 16.84 22.64 30.00 30.00 42.26 30.00 -- 9.83<br />

Lbs -- 5395 4685 4270 4685 4685 -- --<br />

kN -- 24.00 20.84 18.99 20.84 20.84 -- --<br />

Lbs 3785 5090 6745 6745 9500 6745 -- 2210<br />

kN 16.84 22.64 30.00 30.00 42.26 30.00 -- 9.83<br />

Lbs -- 5395 4685 4270 4685 4685 -- --<br />

kN -- 24.00 20.84 18.99 20.84 20.84 -- --<br />

Lbs -- 5395 4685 4270 4685 4685 -- --<br />

kN -- 24.00 20.84 18.99 20.84 20.84 -- --<br />

Lbs -- 5395 4685 4270 4685 4685 -- --<br />

kN -- 24.00 20.84 18.99 20.84 20.84 -- --<br />

Lbs -- 5395 4685 4270 4685 4685 -- --<br />

kN -- 24.00 20.84 18.99 20.84 20.84 -- --<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5280 4435 4880 4880 -- --<br />

kN -- 24.00 23.49 19.73 21.71 21.71 -- --<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

L<br />

H<br />

TF<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

W<br />

D<br />

138<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

continued on next page


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Joist Size<br />

<strong>USP</strong><br />

Stock No. Ref. No.<br />

GLTV5.50/11.25,<br />

PHXU55112 HB5.50/11.25,<br />

5-1/4 x 11-1/4<br />

HWU5.50/11.25<br />

HLBH55112 -- --<br />

5-1/4 x 11-1/2 HLBH55115<br />

5-1/4 x 11-7/8<br />

5-1/4 x 12<br />

5-1/4 x 14<br />

5-1/4 x 16<br />

5-1/4 x 18<br />

BPH55118<br />

MPH55118<br />

PHXU5512<br />

HLBH5512<br />

BPH5514<br />

PHM5514<br />

PHXU5514<br />

HLBH5514<br />

BPH5516<br />

PHM5516<br />

PHXU5516<br />

HLBH5516<br />

-- --<br />

PHM55118 -- --<br />

GLTV5.511,<br />

PHXU55118 HB5.50/11.88,<br />

HWU5.50/11.88<br />

HLBH55118 HGLTV5.511<br />

BPH5518<br />

PHM5518<br />

PHXU5518<br />

HLBH5518<br />

GLTV5.511<br />

WM5.50/11.88<br />

HB5.50/12<br />

-- --<br />

-- --<br />

-- --<br />

GLTV5.514,<br />

HB5.50/14,<br />

HWU5.50/14<br />

HGLTV5.514<br />

-- --<br />

-- --<br />

GLTV5.516,<br />

HB5.50/16,<br />

HWU5.50/16<br />

HGLTV5.516<br />

-- --<br />

-- --<br />

GLTV5.518,<br />

HB5.50/18<br />

HGLTV5.518<br />

Web Stiffener Reqd.<br />

Steel Gauge<br />

x 7<br />

x 7<br />

x 7<br />

x 12<br />

x 7/10<br />

x 7<br />

x 7<br />

x 12<br />

x 7<br />

x 7<br />

x 12<br />

x 7/10<br />

x 7<br />

x 7<br />

x 12<br />

x 7/10<br />

x 7<br />

x 7<br />

x 12<br />

x 7/10<br />

x<br />

7<br />

x 7<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header Joist Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

5-1/2<br />

5-9/16<br />

5-9/16<br />

5-5/8<br />

5-9/16<br />

11-1/4<br />

11-1/4<br />

11-7/8<br />

11-7/8<br />

11-7/8<br />

11-7/8<br />

11-7/8<br />

12<br />

12<br />

14<br />

14<br />

14<br />

14<br />

16<br />

16<br />

16<br />

3-1/4 11.5<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

New products or updated product information are designated in red font.<br />

6<br />

2-1/2<br />

2-1/2<br />

3-1/4<br />

6<br />

2-1/2<br />

3-1/4<br />

6<br />

2-1/2<br />

2-1/2<br />

3-1/4<br />

6<br />

2-1/2<br />

2-1/2<br />

3-1/4<br />

16 6<br />

12<br />

5-9/16 11-1/2 6 12<br />

5-1/2<br />

5-9/16<br />

5-5/8<br />

5-1/2<br />

5-9/16<br />

5-9/16<br />

5-5/8<br />

5-1/2<br />

5-9/16<br />

5-9/16<br />

5-5/8<br />

5-1/2<br />

5-9/16<br />

5-5/8<br />

5-1/2<br />

18<br />

18<br />

18<br />

5-9/16 18<br />

2-1/2<br />

2-1/2<br />

3-1/4<br />

6<br />

--<br />

7<br />

11.5<br />

12<br />

7<br />

11.5<br />

12<br />

--<br />

7<br />

11.5<br />

12<br />

--<br />

7<br />

11.5<br />

12<br />

--<br />

7<br />

11.5<br />

12<br />

2-1/2<br />

3-1/8<br />

3-1/8<br />

2-1/32<br />

3<br />

2-1/2<br />

3-1/8<br />

3-3/4<br />

2-1/2<br />

3-1/8<br />

2-1/32<br />

3<br />

2-1/2<br />

3-1/8<br />

2-1/32<br />

3<br />

2-1/2<br />

3-1/8<br />

2-1/32<br />

3<br />

2-1/2<br />

3-1/8<br />

8 16d 6<br />

8 16d 6<br />

2 16d<br />

2 16d<br />

2 10d<br />

8 16d 6 10d<br />

15 <br />

6 10d<br />

8 16d 6 10d<br />

15 <br />

10 16d<br />

10d<br />

15 6 16d<br />

15 6 16d<br />

10 16d 6<br />

10d<br />

2 16d 2 10d<br />

10d<br />

15 6 16d<br />

2 16d duplex 2 10d<br />

8 16d 6 10d<br />

15 6 16d<br />

10 16d<br />

6 16d<br />

6 10d<br />

6 16d<br />

10 16d 6 10d<br />

2 16d<br />

2 10d<br />

8 16d 6 10d<br />

15 <br />

2 10d<br />

6 16d<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 8.00<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5280 4435 4880 4880 -- --<br />

kN -- 24.00 23.49 19.73 21.71 21.71 -- --<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5280 4435 4880 4880 -- --<br />

kN -- 24.00 23.49 19.73 21.71 21.71 -- --<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5280 4435 4880 4880 -- --<br />

kN -- 24.00 23.49 19.73 21.71 21.71 -- --<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1265<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.63<br />

Lbs -- 5395 5280 4435 4880 4880 -- --<br />

kN -- 24.00 23.49 19.73 21.71 21.71 -- --<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

L<br />

TF<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

H<br />

W<br />

D<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 139<br />

<strong>USP</strong>2240-131


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Joist Size<br />

5-1/4 x 20<br />

7 x 7-1/4<br />

7 x 9-1/4<br />

7 x 9-1/2<br />

7 x 11-1/4<br />

7 x 11-7/8<br />

<strong>USP</strong><br />

Stock No.<br />

PHXU5520<br />

HLBH5520<br />

PHXU71725<br />

BPH71925<br />

PHM35925-2<br />

PHXU71925<br />

HLBH71925<br />

BPH7195<br />

PHM3595-2<br />

PHXU7195<br />

HLBH7195<br />

MPH3595-2<br />

BPH71112<br />

PHXU71112<br />

HLBH71112<br />

MPH35112-2<br />

BPH71118<br />

PHM35118-2<br />

PHXU71118<br />

HLBH71118<br />

MPH35118-2<br />

BPH7114<br />

PHM3514-2<br />

7 x 14 PHXU7114<br />

HLBH7114<br />

MPH3514-2<br />

Ref. No.<br />

HB5.50/20<br />

-- --<br />

-- --<br />

-- --<br />

B7.12/9.5<br />

-- --<br />

GLTV49.5-2,<br />

HB7.12/9.5,<br />

WPI49.5-2<br />

-- --<br />

WMI49.5-2<br />

Web Stiffener Reqd.<br />

x<br />

Steel Gauge<br />

x 7<br />

x 7<br />

-- -- x 7<br />

x 12<br />

7<br />

x 12<br />

x 7/10<br />

x<br />

7<br />

x 7<br />

x 12<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header Joist Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

5-1/2 20 3-1/4 11.5 2-1/2 8 16d 6 10d<br />

5-9/16<br />

7-1/8<br />

7-1/8<br />

-- -- x 7/10 7-1/8<br />

HB7.12/9.25,<br />

WPI49.25-2<br />

x 7 7-1/8<br />

-- --<br />

GLTV411.25-2,<br />

HB7.12/11.25<br />

HGLTV411.25-2<br />

WMI411.25-2<br />

B7.12/11.88<br />

-- --<br />

GLTV411.88-2,<br />

HB7.12/11.88,<br />

HWU7.12/11.88,<br />

WPI411.88-2<br />

HGLTV411.88-2<br />

WMI411.88-2<br />

B7.12/14<br />

WMI414-2<br />

x 12<br />

x 7<br />

x 7<br />

x<br />

12<br />

x 12<br />

x 7/10<br />

x 7<br />

x 7<br />

x 12<br />

x 12<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

20<br />

7-1/4<br />

9-1/4<br />

9-1/2<br />

12 3-1/8 15 6 16d<br />

9-1/4 3 -- 2-3/8 10 16d 6 10d<br />

9-1/4 2-1/2 10 3 2 16d 2<br />

9-1/4<br />

9-1/2<br />

9-1/2<br />

9-1/2<br />

9-1/2 2-1/2<br />

11-1/4<br />

11-1/4<br />

11-1/4<br />

11-1/4<br />

11-7/8<br />

11-7/8<br />

11-7/8<br />

11-7/8<br />

11-7/8<br />

13-1/8 2-1/2<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

New products or updated product information are designated in red font.<br />

6<br />

3-1/4<br />

3-1/4<br />

6<br />

3<br />

2-1/2<br />

3-1/4<br />

6<br />

3<br />

3-1/4<br />

6<br />

2-1/2<br />

3<br />

2-1/2<br />

3-1/4<br />

6<br />

2-1/2<br />

13-1/8<br />

12<br />

--<br />

10<br />

13-1/8<br />

8<br />

2-1/2<br />

3-1/8<br />

2-3/8<br />

3<br />

2-1/2<br />

12 3-1/8<br />

3-3/4<br />

-- 2-3/16<br />

13-1/8<br />

12<br />

8<br />

--<br />

10<br />

13-1/8<br />

12<br />

8<br />

2-1/2<br />

3-1/8<br />

3-3/4<br />

2-3/16<br />

3<br />

2-1/2<br />

3-1/8<br />

3-3/4<br />

8 16d<br />

8 16d 6<br />

15 6<br />

2 16d 2<br />

8<br />

2 16d duplex 2<br />

6 10d<br />

10d<br />

10d<br />

16d<br />

10 16d 6 10d<br />

16d<br />

10d<br />

10d<br />

15 6 16d<br />

10d<br />

10d<br />

8 16d 6 10d<br />

6<br />

10 16d 6<br />

15 6 16d<br />

2 16d duplex 2<br />

10d<br />

10 16d 6 10d<br />

2 16d 2 10d<br />

8 16d 6 10d<br />

15 6 16d<br />

2<br />

16d duplex 2 10d<br />

10 16d 6<br />

-- -- x 7/10 7-1/8 14 2-1/2 10 3 2 16d 2 10d<br />

GLTV414-2,<br />

HB7.12/14, x 7 7-1/8 14 3-1/4 13-1/8 2-1/2 8 16d 6 10d<br />

WPI414-2<br />

HGLTV414-2 x 7 7-1/8 14 6 12 3-1/8 15 6 16d<br />

x 12<br />

14<br />

14<br />

3<br />

2-1/2<br />

--<br />

8<br />

2-3/16<br />

3-3/4<br />

10d<br />

2 16d duplex 2 10d<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 15215 13825 13825 12840 -- 1770<br />

kN -- 68.04 67.68 61.50 61.50 57.12 -- 7.87<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5280 4435 4880 4880 -- --<br />

kN -- 24.00 23.49 19.73 21.71 21.71 -- --<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5280 4435 4880 4880 -- --<br />

kN -- 24.00 23.49 19.73 21.71 21.71 -- --<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs -- 5300 5060 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.51 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs -- 5300 5060 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.51 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5280 4435 4880 4880 -- --<br />

kN -- 24.00 23.49 19.73 21.71 21.71 -- --<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs -- 5300 5060 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.51 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5280 4435 4880 4880 -- --<br />

kN -- 24.00 23.49 19.73 21.71 21.71 -- --<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

W<br />

L<br />

H<br />

D<br />

TF<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

continued on next page<br />

140<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Joist Size<br />

7 x 16<br />

7 x 18<br />

7 x 20<br />

7 x 22<br />

<strong>USP</strong><br />

Stock No.<br />

BPH7116<br />

PHM3516-2<br />

PHXU7116<br />

HLBH7116<br />

MPH3516-2<br />

BPH7118<br />

PHM3518-2<br />

PHXU7118<br />

HLBH7118<br />

MPH3518-2<br />

BPH7120<br />

PHM3520-2<br />

PHXU7120<br />

HLBH7120<br />

BPH7122<br />

PHXU7122<br />

HLBH7122<br />

Ref. No.<br />

B7.12/16<br />

-- --<br />

GLTV416-2,<br />

HB7.12/16,<br />

WPI416-2<br />

HGLTV416-2<br />

WMI416-2<br />

B7.12/18<br />

-- --<br />

GLTV418-2,<br />

HB7.12/18,<br />

HWI418-2<br />

HGLTV418-2<br />

WMI418-2<br />

B7.12/20<br />

-- --<br />

GLTV420-2,<br />

HB7.12/20<br />

B7.12/22<br />

HWI422-2<br />

Web Stiffener Reqd.<br />

Steel Gauge<br />

x 12<br />

x 7/10<br />

x<br />

x<br />

7<br />

x 12<br />

x 7<br />

x<br />

7<br />

x 12<br />

x 7/10<br />

x 7<br />

12<br />

x 12<br />

x 7/10<br />

x 7<br />

-- -- x 7<br />

GLTV422-2,<br />

HB7.12/22,<br />

HGLTV7.12/22<br />

x 12<br />

x<br />

7<br />

x 7<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header Joist Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

16<br />

16<br />

16<br />

16<br />

16<br />

18<br />

18<br />

18<br />

18<br />

18<br />

20<br />

20<br />

20<br />

20<br />

22<br />

22<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

3<br />

2-1/2<br />

10<br />

3-1/4 13-1/8<br />

6 12<br />

2-1/2 8<br />

3<br />

2-1/2<br />

3-1/4<br />

6<br />

3<br />

2-1/2<br />

--<br />

--<br />

10<br />

13-1/8<br />

12<br />

--<br />

10<br />

3-1/8<br />

2-1/2 8 3-3/4<br />

3-1/4 13-1/8 2-1/2<br />

6 12<br />

3 --<br />

3-1/4 13-1/8<br />

2-3/16<br />

3<br />

2-1/2<br />

3-3/4<br />

2-3/16<br />

3<br />

2-1/2<br />

3-1/8<br />

2-3/16<br />

3<br />

3-1/8<br />

2-3/16<br />

2-1/2<br />

10 16d<br />

2 16d<br />

8 16d<br />

15 <br />

2 16d duplex<br />

6 10d<br />

2 10d<br />

6 10d<br />

6 16d<br />

2 10d<br />

10 16d 6 10d<br />

2 16d 2 10d<br />

8 16d 6 10d<br />

15 6 16d<br />

2 16d duplex<br />

10 16d<br />

2 16d<br />

8 16d<br />

2 10d<br />

6 10d<br />

2 10d<br />

6 10d<br />

15 6 16d<br />

10 16d<br />

7-1/8 22 6 12 3-1/8 15 <br />

8<br />

6 10d<br />

16d 6 10d<br />

6 16d<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs -- 5300 5060 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.51 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5280 4435 4880 4880 -- --<br />

kN -- 24.00 23.49 19.73 21.71 21.71 -- --<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs -- 5300 5060 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.51 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5280 4435 4880 4880 -- --<br />

kN -- 24.00 23.49 19.73 21.71 21.71 -- --<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

Lbs -- -- -- -- -- -- 6165 --<br />

kN -- -- -- -- -- -- 27.42 --<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 5395 5280 4435 4880 4880 -- --<br />

kN -- 24.00 23.49 19.73 21.71 21.71 -- --<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1290<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.74<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1335<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.94<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

L<br />

H<br />

TF<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

W<br />

D<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 141<br />

<strong>USP</strong>2240-131


<strong>EWP</strong> Top Mount Hanger Charts continued<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Joist Size<br />

7 x 24<br />

7 x 26<br />

7 x 28<br />

7 x 30<br />

7 x 32<br />

<strong>USP</strong><br />

Stock No.<br />

BPH7124<br />

PHXU7124<br />

HLBH7124<br />

PHXU7126<br />

HLBH7126<br />

PHXU7128<br />

HLBH7128<br />

PHXU7130<br />

HLBH7130<br />

PHXU7132<br />

HLBH7132<br />

Ref. No.<br />

B7.12/24<br />

HWI424-2<br />

GLTV424-2,<br />

HB7.12/24,<br />

HGLTV7.12/24<br />

B7.12/26,<br />

HB7.12/26,<br />

HWI426-2<br />

GLTV426-2,<br />

HB7.12/26<br />

B7.12/28,<br />

HB7.12/28,<br />

HWI428-2<br />

GLTV428-2,<br />

HB7.12/28<br />

HWI430-2<br />

GLTV430-2,<br />

HGLTV430-2<br />

HWI432-2<br />

GLTV432-2,<br />

HGLTV432-2<br />

Web Stiffener Reqd.<br />

Steel Gauge<br />

x 12<br />

x 7<br />

x<br />

x<br />

7<br />

x 7<br />

x 7<br />

x<br />

x 7<br />

x<br />

7<br />

7<br />

x 7<br />

x 7<br />

7<br />

Dimensions (in) Fastener Schedule 2,5,6 Factored Resistance 4<br />

Header Joist Header Material (100%)<br />

Uplift 1<br />

W H D L TF Qty Type Qty Type Unit<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

7-1/8<br />

24 3 -- 2-3/16 10 16d 6 10d<br />

24<br />

24<br />

26<br />

26<br />

28<br />

28<br />

30<br />

30<br />

32<br />

32<br />

3-1/4<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) When I-joist is used as a header, all nails must be 10d x 1-1/2.<br />

3) Masonry compressive strength shall be minimum 1500 psi for MPH hangers.<br />

4) Some listed factored resistances may be increased for short-term loading. Refer to code evaluation reports for <strong>USP</strong> Structural <strong>Connectors</strong> for details.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS<br />

Load tables address hanger/header/fastener limitations only. Joist limitations must be determined for each installation.<br />

6<br />

3-1/4<br />

6<br />

3-1/4<br />

6<br />

3-1/4<br />

6<br />

3-1/4<br />

6<br />

13-1/8<br />

12<br />

13-1/8<br />

12<br />

13-1/8<br />

12<br />

13-1/8<br />

12<br />

13-1/8<br />

12<br />

2-1/2<br />

3-1/8<br />

2-1/2<br />

3-1/8<br />

2-1/2<br />

3-1/8<br />

2-1/2<br />

3-1/8<br />

2-1/2<br />

3-1/8<br />

8<br />

16d 6 10d<br />

15 6 16d<br />

8 16d 6 10d<br />

15<br />

8 16d 6 10d<br />

15<br />

8 16d 6 10d<br />

15<br />

6 16d<br />

8 16d 6 10d<br />

15<br />

6 16d<br />

6 16d<br />

6 16d<br />

DF-L<br />

I-Joist 2<br />

LVL<br />

PSL<br />

LSL<br />

DF-L<br />

SPF<br />

Masonry 3<br />

DF-L 115%<br />

Lbs -- 5300 5055 5435 5055 4725 -- 1245<br />

kN -- 23.58 22.49 24.18 22.49 21.02 -- 5.54<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1335<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.94<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1335<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.94<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1335<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.94<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1335<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.94<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

Lbs -- 9575 8330 9575 7610 5170 -- 1335<br />

kN -- 42.59 37.06 42.59 33.85 23.00 -- 5.94<br />

Lbs -- 15295 14935 13825 13825 12840 -- 1930<br />

kN -- 68.04 66.44 61.50 61.50 57.12 -- 8.59<br />

L<br />

H<br />

TF<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

W<br />

D<br />

142<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Adjustable Rafter-To-Plate <strong>Connectors</strong> – TMP & TMPH series<br />

The TMP and TMPH are designed to make rafter-to-plate<br />

connections and eliminates time-consuming bird’s-mouth<br />

notching or bevel plate installation. Both series are available<br />

in I-Joists sizes, as well as standard 2x sizes.<br />

TMP – Adjusts to pitches from 1/12 to 6/12.<br />

TMPH – Adjusts to pitches from 6/12 to 14/12.<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: TMP – 18 gauge<br />

TMPH – 16 gauge;<br />

Fulcrum – 12 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from<br />

data submitted to various<br />

North American building<br />

code evaluators.<br />

Pitch Range:<br />

TMP – 1 /12 - 6 /12<br />

TMPH – 6 /12 - 14 /12<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Position connector on top plate. Fasten connector to<br />

outside of top plate with specified nails. Insert rafter into<br />

rafter pocket. Adjust rafter and pocket to correct pitch.<br />

Fasten rafter to connector with specified nails. Installing<br />

the TMP requires driving specified nails through the<br />

opposing slots in the pocket. TMPH installation involves<br />

sliding the fulcrum until it supports the pocket at the<br />

desired pitch and nailing down through the fulcrum base<br />

into the top plate to lock the fulcrum into position.<br />

H<br />

Typical TMPH<br />

installation<br />

L<br />

W<br />

D<br />

TMPH<br />

fulcrum<br />

4 11 /16˝<br />

Typical TMP<br />

installation<br />

3 1 /2˝<br />

W<br />

L<br />

TMP<br />

Dimensions (in) Fastener Schedule 2,3<br />

Factored Resistance<br />

Plate Rafter DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Rafter Width Stock No. Ref. No. Gauge W L Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

1-1/2 TMP2 VPA2 18 1-9/16 5-9/16 6 10d 4 10d x 1-1/2 1425 230 6.34 1.02 1225 195 5.45 0.87<br />

1-3/4 TMP175 VPA25 18 1-13/16 5-9/16 6 10d 4 10d x 1-1/2 1655 230 7.36 1.02 1425 195 6.34 0.87<br />

2 or 2-1/8 TMP21<br />

VPA2.06,<br />

VPA2.1<br />

18 2-1/8 6-3/8 6 10d 4 10d x 1-1/2 1860 230 8.27 1.02 1600 195 7.12 0.87<br />

2-5/16 TMP23 VPA35 18 2-3/8 6-3/8 6 10d 4 10d x 1-1/2 2835 230 12.61 1.02 2440 195 10.85 0.87<br />

2-1/2 or 2-5/8 TMP25 VPA3 18 2-11/16 6-3/8 6 10d 4 10d x 1-1/2 2835 230 12.61 1.02 2440 195 10.85 0.87<br />

3 TMP31 -- -- 18 3-1/8 7-5/16 6 10d 4 10d x 1-1/2 2835 230 12.61 1.02 2440 195 10.85 0.87<br />

3-1/2 TMP4 VPA4 18 3-9/16 7-5/16 6 10d 4 10d x 1-1/2 2835 230 12.61 1.02 2440 195 10.85 0.87<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase is allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS<br />

Dimensions (in)<br />

Fastener Schedule 3,4<br />

Plate Rafter 2<br />

<strong>USP</strong><br />

According to Pitch Uplift 1 According to Pitch Uplift 1<br />

Rafter Width Stock No. Ref. No. W H D L Qty Type Qty Type Unit 6/12 7/12 8/12 10/12 12/12 115% 6/12 7/12 8/12 10/12 12/12 115%<br />

1-1/2<br />

1-3/4<br />

TMPH2<br />

TMPH175<br />

VPA2<br />

VPA25<br />

1-9/16<br />

1-13/16<br />

2-1/2<br />

2-3/8<br />

4<br />

4<br />

6-9/16<br />

6-9/16<br />

10<br />

10<br />

10d<br />

10d<br />

8<br />

8<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

Lbs 4595 4565 4480 4090 3485 250 3950 3925 3855 3515 2995 215<br />

kN 20.44 20.31 19.93 18.19 15.50 1.11 17.57 17.46 17.15 15.64 13.32 0.96<br />

Lbs 4595 4565 4480 4090 3485 250 3950 3925 3855 3515 2995 215<br />

kN 20.44 20.31 19.93 18.19 15.50 1.11 17.57 17.46 17.15 15.64 13.32 0.96<br />

2<br />

<br />

Lbs 4595 4565 4480 4090 3485 250 3950 3925 3855 3515 2995 215<br />

TMPH21<br />

2-1/8 2-5/8 4 7-3/8 10 10d 8 10d x 1-1/2<br />

or 2-1/8<br />

VPA2.1<br />

kN 20.44 20.31 19.93 18.19 15.50 1.11 17.57 17.46 17.15 15.64 13.32 0.96<br />

2-5/16 TMPH23 VPA35 2-3/8 2-1/2 4 7-3/8 10 10d 8 10d x 1-1/2<br />

Lbs 4595 4565 4480 4090 3485 250 3950 3925 3855 3515 2995 215<br />

kN 20.44 20.31 19.93 18.19 15.50 1.11 17.57 17.46 17.15 15.64 13.32 0.96<br />

2-1/2<br />

Lbs 4595 4565 4480 4090 3485 250 3950 3925 3855 3515 2995 215<br />

TMPH25 VPA3 2-11/16 2-5/16 4 7-3/8 10 10d 8 10d x 1-1/2<br />

or 2-5/8<br />

kN 20.44 20.31 19.93 18.19 15.50 1.11 17.57 17.46 17.15 15.64 13.32 0.96<br />

3<br />

3-1/2<br />

TMPH31<br />

TMPH4<br />

-- --<br />

VPA4<br />

3-1/8<br />

3-9/16<br />

2-11/16<br />

2-1/2<br />

4<br />

4<br />

8-9/16<br />

8-9/16<br />

10<br />

10<br />

10d<br />

10d<br />

8<br />

8<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

Lbs 4595 4565 4480 4090 3485 250 3950 3925 3855 3515 2995 215<br />

kN 20.44 20.31 19.93 18.19 15.50 1.11 17.57 17.46 17.15 15.64 13.32 0.96<br />

Lbs 4595 4565 4480 4090 3485 250 3950 3925 3855 3515 2995 215<br />

kN 20.44 20.31 19.93 18.19 15.50 1.11 17.57 17.46 17.15 15.64 13.32 0.96<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase is allowed.<br />

2) Web stiffeners are required for all Wood I-Joist installations.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) NAILS<br />

DF-L<br />

Factored Resistance<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 143<br />

<strong>USP</strong>2240-131<br />

S-P-F


Slope/Skew <strong>Hangers</strong> – LSSH series<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

The LSSH series connects rafters to ridge beams in vaulted<br />

roof structures. This series is field adjustable to meet a<br />

variety of skew and/or slope applications. Slopes to any pitch<br />

up to 45° up or down and skews up to 45° right or left.<br />

Materials: See chart<br />

Finish: G90 galvanizing; LSSH15-TZ – G-185<br />

Triple Zinc galvanizing<br />

Options: LSSH210 and LSSH31 are available in Triple<br />

Zinc. To order, add TZ to stock number, as in<br />

LSSH210-TZ. LSSH15 and LSSH210 are<br />

available in Stainless steel. To order, add SS<br />

to stock number, as in LSSH210-SS.<br />

Codes: Factored resistances are derived from data<br />

submitted to various North American building<br />

code evaluators and are in accordance with<br />

CSA O86-09.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

Steps:<br />

1. Position LSSH connector against plumb-cut end of rafter joist.<br />

Fasten joist side flanges with 10d (0.148") x 11/2˝ nails.<br />

Bend seat up to fit against joist bottom and drive<br />

(1) 10d (0.148") x 11/2˝ nail through bottom seat into rafter<br />

bottom. Drive (2) 10d (0.148") x 11/2˝ nails at downward<br />

angle through dimpled nailing guides.<br />

2. Lean connector and rafter end against ridge beam at desired<br />

position. Install 10d (0.148" x 3") or 16d (0.162" x 3 1/2˝) nails<br />

through nail holes into ridge beam at right 90° angle.<br />

If skewing the rafter, only drive nails into ridge beam on inside<br />

flange.<br />

3. Bend outside flange to desired angle.<br />

4. Hammer outside flange until edge touches header. Fasten<br />

outside flange to ridge by driving 10d (0.148" x 3") or<br />

16d (0.162" x 3 1/2˝) nails through nail holes.<br />

• Web stiffeners are required for all wood I-Joist installations.<br />

2<br />

skew to 45˚ 45° maximum<br />

Slope to<br />

45˚ up<br />

or down<br />

LSSH210<br />

1<br />

3 & 4<br />

Typical LSSH179<br />

installation<br />

W 2<br />

Slope to<br />

45˚ up<br />

or down<br />

W 1<br />

LSSH35<br />

Dimensions (in)<br />

Fastener Schedule 2,3<br />

Factored Resistance<br />

Header Rafter DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Rafter <strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Width Stock No. Ref. No. Gauge W1 W2 H Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

SLOPED ONLY HANGERS<br />

1-1/2 LSSH15-TZ<br />

LSU26, LSU26Z,<br />

LSSU28, LSSU28Z<br />

18 1-9/16 1-3/4 5-1/16 6 10d HDG 7 10d x 1-1/2 HDG 1640 1395 7.30 6.21 1165 865 5.18 3.85<br />

1-1/2 LSSH210 LSSU210 18 1-9/16 1-3/4 8-13/16 10 10d 7 10d x 1-1/2 2775 2005 12.34 8.92 1970 1240 8.76 5.52<br />

1-3/4 LSSH179 LSSUI25 18 1-13/16 1-5/8 8-13/16 10 10d 7 10d x 1-1/2 2775 2005 12.34 8.92 1970 1240 8.76 5.52<br />

2 - 2-1/8 LSSH20<br />

LSSUI2.06,<br />

LSSU2.1<br />

18 2-1/8 2-1/2 8-13/16 10 10d 7 10d x 1-1/2 2620 1845 11.65 8.21 1860 1030 8.27 4.58<br />

2-1/4 - 2-5/16 LSSH23 LSSUI35 18 2-5/16 2-3/8 8-13/16 10 10d 7 10d x 1-1/2 2620 1845 11.65 8.21 1860 1030 8.27 4.58<br />

2-1/2 LSSH25 LSSUH310 16 2-9/16 2-3/4 8-13/16 18 16d 12 10d x 1-1/2 4260 2250 18.95 10.01 3025 1390 13.46 6.18<br />

2-5/8 LSSH26 -- -- 16 2-11/16 2-5/8 8-13/16 18 16d 12 10d x 1-1/2 4260 2250 18.95 10.01 3025 1390 13.46 6.18<br />

3 LSSH31 LSSU210-2 16 3-1/8 3-3/4 8-13/16 18 16d 12 10d x 1-1/2 5230 2985 23.27 13.28 3715 1845 16.53 8.21<br />

3-1/2 LSSH35 LSSU410 16 3-9/16 3-1/2 8-13/16 18 16d 12 10d x 1-1/2 5230 2985 23.27 13.28 3715 1845 16.53 8.21<br />

SKEWED HANGERS or SLOPED & SKEWED HANGERS<br />

1-1/2 LSSH15-TZ<br />

LSU26, LSU26Z,<br />

LSSU28, LSSU28Z<br />

18 1-9/16 1-3/4 5-1/16 6 10d HDG 7 10d x 1-1/2 HDG 1340 1395 5.96 6.21 950 865 4.23 3.85<br />

1-1/2 LSSH210 LSSU210 18 1-9/16 1-3/4 8-13/16 10 10d 7 10d x 1-1/2 2775 2005 12.34 8.92 1970 1240 8.76 5.52<br />

1-3/4 LSSH179 LSSUI25 18 1-13/16 1-5/8 8-13/16 10 10d 7 10d x 1-1/2 2775 2005 12.34 8.92 1970 1240 8.76 5.52<br />

2 - 2-1/8 LSSH20<br />

LSSUI2.06,<br />

LSSU2.1<br />

18 2-1/8 2-1/2 8-13/16 10 10d 7 10d x 1-1/2 2620 1845 11.65 8.21 1860 1140 8.27 5.07<br />

2-1/4 - 2-5/16 LSSH23 LSSUI35 18 2-5/16 2-3/8 8-13/16 10 10d 7 10d x 1-1/2 2620 1845 11.65 8.21 1860 1140 8.27 5.07<br />

2-1/2 LSSH25 LSSUH310 16 2-9/16 2-3/4 8-13/16 14 16d 12 10d x 1-1/2 2985 2250 13.28 10.01 2120 1390 9.43 6.18<br />

2-5/8 LSSH26 -- -- 16 2-11/16 2-5/8 8-13/16 14 16d 12 10d x 1-1/2 2985 2250 13.28 10.01 2120 1390 9.43 6.18<br />

3 LSSH31 LSSU210-2 16 3-1/8 3-3/4 8-13/16 14 16d 12 10d x 1-1/2 3145 2985 13.99 13.28 2235 1845 9.94 8.21<br />

3-1/2 LSSH35 LSSU410 16 3-9/16 3-1/2 8-13/16 14 16d 12 10d x 1-1/2 3145 2985 13.99 13.28 2235 1845 9.94 8.21<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

W2<br />

W1<br />

W2<br />

3˝<br />

H<br />

W2<br />

3˝<br />

H<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

144<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Girder <strong>Hangers</strong> – LGU, MGU & HGU series<br />

A<br />

LGU, MGU, and HGU’s are high capacity girder to girder face mount<br />

connectors. Fastening is by WS structural screws for ease of<br />

installation. Fastenings are placed high on the connector to permit the<br />

connection of a deep carried member to a shallower carrying member.<br />

Very useful where tops of beams must be flush.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Options: See Specialty Options Chart.<br />

NEW<br />

H1<br />

H<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• WS structural screws supplied with connector.<br />

Substituting with lag screws will reduce capacity.<br />

• Beams comprised of multiple plies must be laminated<br />

to act as a single member.<br />

• Multi-ply carrying beams may require additional connection<br />

of laminations at connector.<br />

Typical LGU, MGU, HGU<br />

installation<br />

W<br />

D<br />

LGU, MGU, HGU<br />

Beam <strong>USP</strong><br />

Steel H 2<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Width Stock No. Ref. No. Gauge W (min) H1 D A Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

3-1/8 LGU325 LGU3.25-SDS 10 3-1/4 8 7-3/8 4-1/2 3-1/4 18 WS3 12 WS3 10760 7835 47.86 34.85 7640 5565 33.99 24.76<br />

LGU363 LGU3.63-SDS 10 3-5/8 8 7-3/8 4-1/2 3-1/4 18 WS3 12 WS3 10760 7835 47.86 34.85 7640 5565 33.99 24.76<br />

3-1/2 MGU363 MGU3.63-SDS 10 3-5/8 9-1/4 8-5/8 4-1/2 4 24 WS3 16 WS3 17465 9605 77.69 42.73 12400 6820 55.16 30.34<br />

HGU363 HGU3.63-SDS 7 3-5/8 11 10-3/8 5-1/4 4-3/4 38 WS3 24 WS3 24285 13630 108.03 60.63 17245 9675 76.71 43.04<br />

LGU525 LGU5.25-SDS 10 5-1/4 8 7-3/8 4-1/2 3-1/4 18 WS3 12 WS3 10760 7835 47.86 34.85 7640 5565 33.99 24.76<br />

5-1/8 MGU525 MGU5.25-SDS 10 5-1/4 9-1/4 8-5/8 4-1/2 4 24 WS3 16 WS3 17465 9605 77.69 42.73 12400 6820 55.16 30.34<br />

HGU525 HGU5.25-SDS 7 5-1/4 11 10-3/8 5-1/4 4-3/4 38 WS3 24 WS3 24285 13630 108.03 60.63 17245 9675 76.71 43.04<br />

5-1/4<br />

5-1/2<br />

6-3/4<br />

MGU550 MGU5.50-SDS 10 5-1/2 9-1/4 8-5/8 4-1/2 4 24 WS3 16 WS3 17465 9605 77.69 42.73 12400 6820 55.16 30.34<br />

HGU550 HGU5.50-SDS 7 5-1/2 11 10-3/8 5-1/4 4-3/4 38 WS3 24 WS3 24285 13630 108.03 60.63 17245 9675 76.71 43.04<br />

MGU562 MGU5.62-SDS 10 5-5/8 9-1/4 8-5/8 4-1/2 4 24 WS3 16 WS3 17465 9605 77.69 42.73 12400 6820 55.16 30.34<br />

HGU562 HGU5.62-SDS 7 5-5/8 11 10-3/8 5-1/4 4-3/4 38 WS3 24 WS3 24285 13630 108.03 60.63 17245 9675 76.71 43.04<br />

MGU700 MGU7.00-SDS 10 7 9-1/4 8-5/8 4-1/2 4 24 WS3 16 WS3 17465 9605 77.69 42.73 12400 6820 55.16 30.34<br />

HGU700 HGU7.00-SDS 7 7 11 10-3/8 5-1/4 4-3/4 38 WS3 24 WS3 24285 13630 108.03 60.63 17245 9675 76.71 43.04<br />

7 HGU725 HGU7.25-SDS 7 7-1/4 11 10-3/8 5-1/4 4-3/4 38 WS3 24 WS3 24285 13630 108.03 60.63 17245 9675 76.71 43.04<br />

8-3/4 HGU900 HGU9.00-SDS 7 9 11 10-3/8 5-1/4 4-3/4 38 WS3 24 WS3 24285 13630 108.03 60.63 17245 9675 76.71 43.04<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) "Specify" denotes the required supported beam height that must be specified at the time of ordering.<br />

3) WS3 Wood Screws are 1/4" x 3" long and are included in hangers.<br />

New products or updated product information are designated in red font.<br />

Option <strong>USP</strong> Series Skewed 1 Inverted Flange<br />

Range<br />

LGU<br />

MGU<br />

HGU<br />

LGU<br />

<br />

55% of table value.<br />

One Inverted-Flange option<br />

available on some sizes. See<br />

footnotes 2 and 3.<br />

Factored<br />

Resistance<br />

Ordering<br />

MGU<br />

HGU<br />

LGU<br />

MGU<br />

HGU<br />

Dimensions (in)<br />

30% of uplift.<br />

65% of table value.<br />

30% of uplift.<br />

70% of table value.<br />

30% of uplift.<br />

Add SK, angle required and<br />

right (R) or left (L), to product number.<br />

Ex. LGU525H18-SK45R<br />

100% of table value<br />

Add 1IF and right (R) or left (L)<br />

to product number.<br />

Ex. LGU525H18-1IFR<br />

1) Skewed hangers with skews greater than 15° may have all joist fasteners on outside flange.<br />

2) One inverted-flange (1IF) is available on the following sizes.<br />

LGU363, LGU525<br />

MGU525, MGU550, MGU563, MGU700<br />

HGU525, HGU550, HGU562,HGU700, HGU725, HGU900<br />

3) The inverted flange option is not available on skewed LGU, MGU or HGU hangers.<br />

Fastener Schedule 3<br />

Header<br />

Truss<br />

DF-L (Lbs)<br />

Specialty Options Chart – refer to Specialty Options pages 210 to 211 for additional details.<br />

Factored Resistance<br />

DF-L (kN)<br />

S-P-F (Lbs)<br />

S-P-F (kN)<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 145<br />

<strong>USP</strong>2240-131


Glulam Face Mount <strong>Hangers</strong> – GHF series<br />

2 1/8˝H<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

Materials: See chart<br />

Finish: <strong>USP</strong> primer<br />

Options: See Specialty Options Chart.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

Dimensions (in) Fastener Schedule 2<br />

Factored Resistance 1<br />

Header Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Glulam <strong>USP</strong><br />

Steel<br />

Floor Uplift 3 Floor Uplift 3 Floor Uplift 3 Floor Uplift 3<br />

Size Stock No. Ref. No. Gauge W H D Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

3-1/8 x 6 GHF31600 -- -- 12 3-3/16 5-7/8 2-3/8 10 WS25 4 WS25 3155 1450 14.03 6.45 2650 1220 11.79 5.43<br />

3-1/8 x 7-1/2 GHF31750 -- -- 12 3-3/16 7-3/8 2-3/8 12 WS25 4 WS25 3785 1450 16.84 6.45 3180 1220 14.15 5.43<br />

3-1/8 x 9 GHF31900 -- -- 12 3-3/16 8-7/8 2-3/8 16 WS25 5 WS25 5045 1810 22.44 8.05 4240 1520 18.86 6.76<br />

3-1/8 x 10-1/2 GHF31105 -- -- 12 3-3/16 10-3/8 2-3/8 20 WS25 6 WS25 6305 2175 28.05 9.68 5295 1825 23.55 8.12<br />

3-1/8 x 12 GHF31120 -- -- 12 3-3/16 11-7/8 2-3/8 22 WS25 6 WS25 6940 2175 30.87 9.68 5830 1825 25.93 8.12<br />

3-1/8 x 13-1/2 GHF31135 -- -- 12 3-3/16 13-3/8 2-3/4 24 WS25 6 WS25 7565 2175 33.65 9.68 6355 1825 28.27 8.12<br />

3-1/8 x 15 GHF31150 -- -- 12 3-3/16 14-7/8 2-3/4 26 WS25 7 WS25 8200 2540 36.48 11.30 6890 2135 30.65 9.50<br />

3-1/8 x 16-1/2 GHF31165 -- -- 12 3-3/16 16-3/8 2-3/4 28 WS25 9 WS25 8825 3265 39.26 14.52 7415 2745 32.98 12.21<br />

3-1/8 x 18 GHF31178 -- -- 12 3-3/16 17-3/4 2-3/4 30 WS25 11 WS25 9460 3990 42.08 17.75 7945 3350 35.34 14.90<br />

3-1/4 x 9 GHF32900 -- -- 12 3-5/16 8-7/8 2-3/8 16 WS25 5 WS25 5045 2175 22.44 9.68 4240 1825 18.86 8.12<br />

3-1/4 x 12 GHF32120 -- -- 12 3-5/16 11-7/8 2-3/8 22 WS25 6 WS25 6940 2175 30.87 9.68 5830 1825 25.93 8.12<br />

5-1/8 x 6 GHF51600 -- -- 12 5-3/16 5-7/8 2-3/8 10 WS3 4 WS3 3155 1450 14.03 6.45 2650 1220 11.79 5.43<br />

5-1/8 x 7-1/2 GHF51750 -- -- 12 5-3/16 7-3/8 2-3/8 14 WS3 4 WS3 4415 1450 19.64 6.45 3710 1220 16.50 5.43<br />

5-1/8 x 9 GHF51900 -- -- 12 5-3/16 8-7/8 2-3/8 18 WS3 5 WS3 5675 1810 25.24 8.05 4765 1520 21.20 6.76<br />

5-1/8 x 10-1/2 GHF51105 -- -- 12 5-3/16 10-3/8 2-3/8 22 WS3 6 WS3 6940 2175 30.87 9.68 5830 1825 25.93 8.12<br />

5-1/8 x 12 GHF51120 -- -- 12 5-3/16 11-7/8 2-3/8 24 WS3 6 WS3 7565 2175 33.65 9.68 6355 1825 28.27 8.12<br />

5-1/8 x 13-1/2 GHF51135 -- -- 7 5-3/16 13-3/8 2-3/8 26 WS3 6 WS3 9360 2485 41.64 11.05 7860 2085 34.96 9.27<br />

5-1/8 x 15 GHF51150 -- -- 7 5-3/16 14-7/8 2-3/4 28 WS3 7 WS3 10080 2900 44.84 12.90 8465 2435 37.66 10.83<br />

5-1/8 x 16-1/2 GHF51165 -- -- 7 5-3/16 16-3/8 2-3/4 30 WS3 7 WS3 10800 2900 48.04 12.90 9070 2435 40.35 10.83<br />

5-1/8 x 18 GHF51178 -- -- 7 5-3/16 17-3/4 2-3/4 32 WS3 8 WS3 11520 3310 51.25 14.72 9675 2780 43.04 12.37<br />

5-1/8 x 19-1/2 GHF51192 -- -- 7 5-3/16 19-1/8 2-3/4 34 WS3 8 WS3 12240 3310 54.45 14.72 10280 2780 45.73 12.37<br />

5-1/8 x 21 GHF51205 -- -- 7 5-3/16 20-3/8 2-3/4 36 WS3 9 WS3 12960 3725 57.65 16.57 10885 3130 48.42 13.92<br />

5-1/8 x 24 GHF51233 -- -- 7 5-3/16 23-1/4 2-3/4 40 WS3 11 WS3 14400 4555 64.06 20.26 12095 3825 53.80 17.02<br />

5-1/4 x 9 GHF52900 -- -- 12 5-5/16 8-7/8 2-3/8 18 WS3 5 WS3 5675 1810 25.24 8.05 4765 1520 21.20 6.76<br />

5-1/4 x 12 GHF52120 -- -- 12 5-5/16 11-7/8 2-3/8 24 WS3 6 WS3 7565 2175 33.65 9.68 6355 1825 28.27 8.12<br />

6-3/4 x 6 GHF67600 -- -- 12 6-7/8 5-7/8 2-3/8 12 WS3 4 WS3 3785 1450 16.84 6.45 3180 1220 14.15 5.43<br />

6-3/4 x 7-1/2 GHF67750 -- -- 12 6-7/8 7-3/8 2-3/8 16 WS3 5 WS3 5045 1810 22.44 8.05 4240 1520 18.86 6.76<br />

6-3/4 x 9 GHF67900 -- -- 12 6-7/8 8-7/8 2-3/8 20 WS3 6 WS3 6305 2175 28.05 9.68 5295 1825 23.55 8.12<br />

6-3/4 x 10-1/2 GHF67105 -- -- 12 6-7/8 10-3/8 2-3/8 24 WS3 8 WS3 7565 2905 33.65 12.92 6355 2440 28.27 10.85<br />

6-3/4 x 12 GHF67120 -- -- 7 6-7/8 11-7/8 2-3/4 28 WS3 8 WS3 10080 3310 44.84 14.72 8465 2780 37.66 12.37<br />

6-3/4 x 13-1/2 GHF67135 -- -- 7 6-7/8 13-3/8 2-3/4 30 WS3 8 WS3 10800 3310 48.04 14.72 9070 2780 40.35 12.37<br />

6-3/4 x 15 GHF67150 -- -- 7 6-7/8 14-7/8 2-3/4 32 WS3 10 WS3 11520 4140 51.25 18.42 9675 3480 43.04 15.48<br />

6-3/4 x 16-1/2 GHF67165 -- -- 7 6-7/8 16-3/8 2-3/4 34 WS3 10 WS3 12240 4140 54.45 18.42 10280 3480 45.73 15.48<br />

6-3/4 x 18 GHF67180 -- -- 7 6-7/8 17-3/4 2-3/4 36 WS3 12 WS3 12960 4970 57.65 22.11 10885 4175 48.42 18.57<br />

6-3/4 x 19-1/2 GHF67195 -- -- 7 6-7/8 19-1/8 3 40 WS3 14 WS3 14400 5795 64.06 25.78 12095 4870 53.80 21.66<br />

6-3/4 x 21 GHF67210 -- -- 7 6-7/8 20-3/8 3 44 WS3 18 WS3 15840 7450 70.46 33.14 13305 6260 59.19 27.85<br />

6-3/4 x 22-1/2 GHF67225 -- -- 7 6-7/8 21-7/8 3 46 WS3 20 WS3 16560 8280 73.67 36.83 13910 6955 61.88 30.94<br />

6-3/4 x 24 GHF67240 -- -- 7 6-7/8 23-1/4 3 48 WS3 22 WS3 17280 9110 76.87 40.52 14515 7650 64.57 34.03<br />

1) Factored resistances based on seat bearing calculated at 560 psi perpendicular to grain.<br />

<br />

3) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

New products or updated product information are designated in red font.<br />

W<br />

GHF<br />

D<br />

Typical GHF51135<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Option Skewed 1,3 Sloped Seat 2 Sloped / Skewed 1,2 Inverted Flange<br />

Range <br />

<br />

<br />

<br />

Factored<br />

<br />

<br />

<br />

<br />

Resistance<br />

<br />

<br />

<br />

<br />

<br />

146<br />

Specialty Options Chart – refer to Specialty Options pages 210 to 211 for additional details.<br />

Ordering<br />

SK, (R)<br />

(L), <br />

<br />

SL, <br />

(U) (D),<br />

<br />

<br />

<br />

<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

IF <br />

<br />

Typical<br />

GHF51135IF<br />

inverted flange<br />

installation


Bolted Glulam Beam <strong>Hangers</strong> – KEG, KLEG, & KMEG series<br />

Bolt-only fastening, heavy steel construction, and a<br />

continuous top flange allow the KLEG, KMEG, and<br />

KEG products to have high load capacities.<br />

KLEG – (4) bolt light-duty hanger.<br />

KMEG – (6) bolt medium-duty hanger.<br />

KEG – (8) bolt heavy-duty hanger.<br />

3˝<br />

3˝<br />

W<br />

L<br />

D<br />

4˝<br />

3˝<br />

TF<br />

8 1 /4˝<br />

H<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: See chart<br />

Finish: <strong>USP</strong> primer<br />

Options: See Specialty Options Chart.<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Beam height dimension (H) must<br />

be specified when ordering.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes,<br />

page 10.<br />

• Bolts are not supplied unless ordered separately.<br />

Bolts provided by other suppliers must meet or<br />

exceed ASTM A 307 Grade A, or ASME SAE Grade 2,<br />

or better.<br />

• Minimum header height is 10˝ for the KLEG;<br />

13˝ for the KMEG; 20˝ for the KEG.<br />

4˝<br />

4˝<br />

W<br />

KLEG3<br />

L<br />

4˝<br />

4˝<br />

4˝<br />

4˝<br />

D<br />

KEG5<br />

TF<br />

17 1 /2˝<br />

H<br />

3˝<br />

3˝<br />

Typical KLEG5<br />

installation<br />

L<br />

D<br />

KMEG5<br />

TH<br />

4˝<br />

3˝<br />

3˝<br />

11 1 /4˝<br />

H<br />

Steel Gauge Dimensions (in) Fastener Schedule<br />

Factored Resistance 1<br />

Header Joist<br />

DF-L<br />

S-P-F<br />

Beam <strong>USP</strong><br />

Top U-<br />

Bolt Bolt<br />

Vertical 100% Uplift 115% 2 Vertical 100% Uplift 115% 2<br />

Width Stock No. Ref. No Flange Strap W H 3 D TF L Qty Dia. Qty Dia. Application Lbs kN Lbs kN Lbs kN Lbs kN<br />

3-1/8 KLEG3 LEG3 7 7 3-1/4 specify 6 2-1/2 12 4 3/4 2 3/4<br />

With Top Flange 15060 66.99 4040 17.97 12950 57.61 3475 15.46<br />

Without Top Flange 5125 22.80 4040 17.97 4410 19.62 3475 15.46<br />

KLEG5 LEG5 7 7 5-1/4 specify 6 2-1/2 12 4 3/4 2 3/4<br />

With Top Flange 15060 66.99 5910 26.29 12950 57.61 5085 22.62<br />

Without Top Flange 5125 22.80 5910 26.29 4410 19.62 5085 22.62<br />

5-1/8 KMEG5 MEG5 7 7 5-1/4 specify 6 2-1/2 12 6 3/4 2 3/4<br />

With Top Flange 17555 78.09 5915 26.31 15095 67.15 5085 22.62<br />

Without Top Flange 7620 33.90 5915 26.31 6555 29.16 5085 22.62<br />

KEG5 EG5 1/4 7 5-1/4 specify 6 2-1/2 12 8 1 2 1<br />

With Top Flange 23125 102.87 7625 33.92 19890 88.48 6560 29.18<br />

Without Top Flange 13190 58.67 7625 33.92 11345 50.47 6560 29.18<br />

KLEG7 LEG7 7 7 6-7/8 specify 6 2-1/2 12 4 3/4 2 3/4<br />

With Top Flange 15060 66.99 5910 26.29 12950 57.61 5085 22.62<br />

Without Top Flange 5125 22.80 5910 26.29 4410 19.62 5085 22.62<br />

6-3/4 KMEG7 MEG7 7 7 6-7/8 specify 6 2-1/2 12 6 3/4 2 3/4<br />

With Top Flange 17555 78.09 5910 26.29 15095 67.15 5085 22.62<br />

Without Top Flange 7620 33.90 5910 26.29 6555 29.16 5085 22.62<br />

KEG7 EG7 1/4 7 6-7/8 specify 6 2-1/2 13-1/2 8 1 2 1<br />

With Top Flange 24410 108.59 9595 42.68 20995 93.39 8250 36.70<br />

Without Top Flange 13235 58.87 9595 42.68 11380 50.62 8250 36.70<br />

8-3/4 KEG9 EG9 1/4 7 8-7/8 specify 6 2-1/2 15-1/2 8 1 2 1<br />

With Top Flange 26100 116.10 9580 42.62 22445 99.84 8240 36.65<br />

Without Top Flange 13270 59.03 9580 42.62 11410 50.76 8240 36.65<br />

10-3/4 KEG11 -- -- 1/4 7 10-7/8 specify 6 2-1/2 17-1/2 8 1 2 1<br />

With Top Flange 27785 123.60 9570 42.57 23895 106.29 8230 36.61<br />

Without Top Flange 13300 59.16 9570 42.57 11440 50.89 8230 36.61<br />

1) Factored resistances are for a supporting member with a width of 5-1/2", and 460 psi perpendicular to grain loading in single shear.<br />

2) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

3) "Specify" denotes the required supported beam height that must be specified at the time of ordering.<br />

Specialty Options Chart – refer to Specialty Options pages 210 and 212 for additional details.<br />

Option Skewed 3 Sloped Seat Top Flange Offset 1,2<br />

Range <br />

<br />

-- --<br />

Factored<br />

Resistance<br />

Ordering<br />

KLEG - 14400 lbs. Max.<br />

KMEG - 14400 lbs. Max.<br />

KEG - 20520 lbs. Max.<br />

Add SK, angle required,<br />

and right (R) or left (L),<br />

to product number.<br />

Ex. KLEG3H112-SK45R<br />

KLEG - 13920 lbs. Max.<br />

KMEG - 13920 lbs. Max.<br />

KEG - 13920 lbs. Max.<br />

Add SL, slope required,<br />

and up (U) or down (D),<br />

to product number.<br />

Ex. KLEG3H112-SL30D<br />

KLEG - 8160 lbs. Max.<br />

<br />

KMEG - 8160 lbs. Max.<br />

<br />

Add OS, and<br />

right (R) or left (L),<br />

to product number.<br />

Ex. KLEG3H112-OSL<br />

1) Top flange offset hangers may not be skewed. 3) Carried member must have square cut end on skewed option. Refer to<br />

2) Top flange offset option is not available for KEG mode Typical PHXU hanger, skewed, left shown, Type B illustration on page 212.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 147<br />

<strong>USP</strong>2240-131


Glulam <strong>Hangers</strong> – KGB, KHGB, & KHHB series<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

These hangers cover medium-to-heavy glulam beam and<br />

purlin applications.<br />

KHHB – Medium-duty hanger.<br />

KGB – Medium to heavy-duty hanger.<br />

KHGB – Heavy-duty hanger.<br />

Materials: 7 gauge<br />

Finish: <strong>USP</strong> primer<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Beam height dimension (H) must<br />

be specified when ordering.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Minimum height (H) is 71/2˝.<br />

See Welded Installation chart on page 213<br />

Typical KHHB installation<br />

H<br />

D<br />

W<br />

KHHB<br />

2 1 /2˝<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Beam<br />

Width<br />

3-1/8<br />

5-1/8<br />

6-3/4<br />

<strong>USP</strong><br />

Stock No.<br />

Steel<br />

Dimensions (in) 3<br />

Fastener Schedule 5<br />

Factored Resistance 1<br />

Header 4 Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Top Face Vertical Uplift 2 Vertical Uplift 2 Vertical Uplift 2 Vertical Uplift 2<br />

Ref. No. Gauge W H 3 D Qty Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

KHHB3 HHB3 7 3-1/4 specify 3 4 6 WS3 6 WS3 7035 2525 31.29 11.23 5910 2120 26.29 9.43<br />

KGB3 GB3 7 3-1/4 specify 3-1/2 4 10 WS3 6 WS3 9300 2525 41.37 11.23 7810 2120 34.74 9.43<br />

KHHB5 HHB5 7 5-1/4 specify 3 4 6 WS3 6 WS3 7035 2525 31.29 11.23 5910 2120 26.29 9.43<br />

KGB5 GB5 7 5-1/4 specify 3-1/2 4 10 WS3 6 WS3 9300 2525 41.37 11.23 7810 2120 34.74 9.43<br />

KHGB5 HGB5 7 5-1/4 specify 4 4 12 WS3 6 WS3 10845 2525 48.24 11.23 9110 2120 40.52 9.43<br />

KHHB7 HHB7 7 6-7/8 specify 3 4 6 WS3 6 WS3 7035 2525 31.29 11.23 5910 2120 26.29 9.43<br />

KGB7 GB7 7 6-7/8 specify 3-1/2 4 10 WS3 6 WS3 9300 2525 41.37 11.23 7810 2120 34.74 9.43<br />

KHGB7 HGB7 7 6-7/8 specify 4 4 12 WS3 6 WS3 10845 2525 48.24 11.23 9110 2120 40.52 9.43<br />

1) Factored resistances are based on 560 psi perpendicular to grain loading.<br />

2) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

3) "Specify" denotes the required supported beam height must be specified at the time of ordering.<br />

<br />

<br />

148<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Glulam Beam <strong>Hangers</strong> – KGLT & KHGLT series<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

These heavy beam hangers are designed for use with glulam<br />

and timber beams. The continuous top mount flange offers high<br />

load capacity with minimal nailing.<br />

KGLT – Medium-duty hanger.<br />

KHGLT – Heavy-duty hanger.<br />

Materials: Top Flange – 3 gauge; U-Strap – 7 gauge<br />

Finish: <strong>USP</strong> primer<br />

Options: See Specialty Options Chart.<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Beam height dimension (H) must<br />

be specified when ordering.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

L<br />

Typical KGLT5 installation<br />

L<br />

2 1 3<br />

/2˝<br />

1 /2˝<br />

2 1 /2˝<br />

6 3 /4˝<br />

H<br />

H<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

W<br />

6˝<br />

W<br />

5˝<br />

See Welded Installation chart on page 213<br />

KHGLT<br />

KGLT<br />

Beam<br />

Width<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) KGLT load values based on 460 psi perpendicular to grain loading. KHGLT load values based on 460 psi or 625 psi perpendicular to grain loading.<br />

3) "Specify" denotes the required supported beam height that must be specified at time of ordering, withbeing the minimum.<br />

<br />

5) No further increase for duration of load allowed.<br />

New products or updated product information are designated in red font.<br />

Specialty Options Chart – refer to Specialty Options pages 210 and 212 for additional details.<br />

Option Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Sloped Top Flange 4 Top Flange Offset Saddle<br />

Range <br />

Factored<br />

Resistance<br />

Ordering<br />

<strong>USP</strong><br />

Stock No.<br />

<br />

<br />

SK, <br />

(R) (L),<br />

<br />

<br />

Dimensions (in)<br />

<br />

<br />

SL, <br />

(U) (D),<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

Top<br />

Fastener Schedule 4 Factored Resistance 2,5<br />

Header Joist<br />

F C^ = 460 psi<br />

F C^ = 625 psi<br />

Uplift 1<br />

Face<br />

DF-L (100%) S-P-F (100%) DF-L (100%) S-P-F (100%) DF-L (115%) S-P-F (115%)<br />

Ref. No. W H 3 L Qty Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN<br />

3-1/8 KGLT3 GLT3 3-1/4 specify 10 4 6 WS3 8 WS3 10865 48.33 9125 40.59 --- --- --- --- 2970 13.21 2495 11.10<br />

3-1/2 KGLT4 GLT4, GLTV4 3-5/8 specify 10 4 6 WS3 8 WS3 10865 48.33 9125 40.59 --- --- --- --- 2970 13.21 2495 11.10<br />

5-1/8 KGLT5 GLT5, GLTV5 5-1/4 specify 10 4 6 WS3 8 WS3 10865 48.33 9125 40.59 --- --- --- --- 2970 13.21 2495 11.10<br />

5-1/2 KGLT6 GLT6, GLTV6 5-5/8 specify 10 4 6 WS3 8 WS3 10865 48.33 9125 40.59 --- --- --- --- 2970 13.21 2495 11.10<br />

6-3/4 KGLT7 GLT7, GLTV7.12 6-7/8 specify 12 4 6 WS3 8 WS3 10865 48.33 9125 40.59 --- --- --- --- 2970 13.21 2495 11.10<br />

8-3/4 KGLT9 -- -- 8-7/8 specify 14 4 6 WS3 8 WS3 10865 48.33 9125 40.59 --- --- --- --- 2970 13.21 2495 11.10<br />

3-1/8 KHGLT3 HGLT3 3-1/4 specify 12 6 12 WS3 6 WS3 14615 65.01 12275 54.60 18670 83.05 15685 69.77 2525 11.23 2120 9.43<br />

3-1/2 KHGLT4 HGLT4, HGLTV4 3-5/8 specify 12 6 12 WS3 6 WS3 15105 67.19 12690 56.45 18670 83.05 15685 69.77 2525 11.23 2120 9.43<br />

5-1/8 KHGLT5 HGLT5, HGLTV5 5-1/4 specify 12 6 12 WS3 6 WS3 15105 67.19 12690 56.45 18670 83.05 15685 69.77 2525 11.23 2120 9.43<br />

5-5/16 KHGLT537 HGLTV5.37 5-3/8 specify 12 6 12 WS3 6 WS3 15105 67.19 12690 56.45 18670 83.05 15685 69.77 2525 11.23 2120 9.43<br />

5-1/2 KHGLT6 HGLT6, HGLTV6 5-5/8 specify 12 6 12 WS3 6 WS3 15105 67.19 12690 56.45 18670 83.05 15685 69.77 2525 11.23 2120 9.43<br />

6-3/4 KHGLT7 HGLT7, HGLTV7.12 6-7/8 specify 12 6 12 WS3 6 WS3 15105 67.19 12690 56.45 18670 83.05 15685 69.77 2525 11.23 2120 9.43<br />

8-3/4 KHGLT9 HGLT9, HGLTV9 8-7/8 specify 14 6 12 WS3 6 WS3 16760 74.56 14080 62.63 19295 85.83 16210 72.11 2525 11.23 2120 9.43<br />

10-3/4 KHGLT11 -- -- 10-7/8 specify 16 6 12 WS3 6 WS3 18420 81.94 15475 68.84 19295 85.83 16210 72.11 2525 11.23 2120 9.43<br />

<br />

<br />

<br />

SF, <br />

(R) (L),<br />

<br />

<br />

<br />

<br />

<br />

<br />

OS, <br />

(R) (L),<br />

<br />

<br />

<br />

<br />

SA, <br />

<br />

<br />

<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 149<br />

<strong>USP</strong>2240-131


Glulam Saddle <strong>Hangers</strong> – KGLS, KGLST, KHGLS, & KHGLST series<br />

<strong>EWP</strong> <strong>Hangers</strong><br />

KGLS – Saddle hanger.<br />

KGLST – Saddle hanger with seismic straps.<br />

KHGLS – Heavier version of KGLS.<br />

KHGLST – Heavier version of KGLST.<br />

Materials: Top flange - 3 gauge; Stirrup - 7 gauge<br />

Finish: <strong>USP</strong> primer<br />

Options: See KGLS & KHGLS Specialty Options Chart.<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Beam height dimension (H) must<br />

be specified when ordering.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Loads and nail schedule apply to each saddle hanger stirrup.<br />

• Minimum header height is 81⁄ 2˝ for the KGLS; 8 1 ⁄ 2˝ for the KGLST;<br />

101⁄ 2˝ for the KHGLS, and 10 1 ⁄ 2˝ for the KHGLST.<br />

• KGLST and KHGLST models include seismic straps which must be<br />

installed with (3) 3⁄4˝ thru-bolts in each supported member and (2) 3⁄4˝<br />

thru-bolts into the supporting beams.<br />

W<br />

TF<br />

L<br />

D<br />

KGLS<br />

H<br />

H<br />

Typical KHGLST35<br />

installation<br />

W<br />

TF<br />

L<br />

D<br />

KHGLST<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Supported<br />

Glulam<br />

Beam Size<br />

3-1/8<br />

5-1/8<br />

6-3/4<br />

8-3/4<br />

<strong>USP</strong><br />

Stock No.<br />

Dimensions (in) 3<br />

Wood Screws 2,5<br />

Header<br />

Fastener Schedule<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Ref. No. W H 7 D L TF Qty Type Qty Type Qty Dia. Qty Dia. 100% 115% 100% 115% 100% 115% 100% 115%<br />

KGLS35 GLS3-5 3-1/4 specify 5 6 5-1/4 6 WS3 6 WS3 -- -- -- -- -- -- -- -- 14795 2525 65.81 11.23 12430 2120 55.29 9.43<br />

KGLST35 -- -- 3-1/4 specify 6-1/2 10 5-1/4 6 WS3 6 WS3 2 3/4 3 3/4 18575 2525 82.63 11.23 15605 2120 69.42 9.43<br />

KGLS37 GLS3-7 3-1/4 specify 5 6 6-7/8 6 WS3 6 WS3 -- -- -- -- -- -- -- -- 14795 2525 65.81 11.23 12430 2120 55.29 9.43<br />

KGLST37 -- -- 3-1/4 specify 6-1/2 10 6-7/8 6 WS3 6 WS3 2 3/4 3 3/4 18575 2525 82.63 11.23 15605 2120 69.42 9.43<br />

KGLS39 GLS3-9 3-1/4 specify 5 6 8-7/8 6 WS3 6 WS3 -- -- -- -- -- -- -- -- 14795 2525 65.81 11.23 12430 2120 55.29 9.43<br />

KGLST39 -- -- 3-1/4 specify 6-1/2 10 8-7/8 6 WS3 6 WS3 2 3/4 3 3/4 18575 2525 82.63 11.23 15605 2120 69.42 9.43<br />

KGLS55 GLS5-5 5-1/4 specify 5 9 5-1/4 6 WS3 6 WS3 -- -- -- -- -- -- -- -- 21180 2525 94.22 11.23 17790 2120 79.14 9.43<br />

KGLST55 -- -- 5-1/4 specify 6-1/2 12 5-1/4 6 WS3 6 WS3 2 3/4 3 3/4 27380 2525 121.80 11.23 23000 2120 102.31 9.43<br />

KGLS57 GLS5-7 5-1/4 specify 5 9 6-7/8 6 WS3 6 WS3 -- -- -- -- -- -- -- -- 22860 2525 101.69 11.23 19200 2120 85.41 9.43<br />

KGLST57 -- -- 5-1/4 specify 6-1/2 12 6-7/8 6 WS3 6 WS3 2 3/4 3 3/4 29060 2525 129.27 11.23 24410 2120 108.59 9.43<br />

KHGLS5 HGLS5 5-1/4 specify 6-1/2 12 specify 14 WS3 8 WS3 -- -- -- -- -- -- -- -- 29785 3365 132.50 14.97 25020 2825 111.30 12.57<br />

KHGLST5 -- -- 5-1/4 specify 6 12 specify 14 WS3 8 WS3 2 3/4 3 3/4 27720 3365 123.31 14.97 23285 2825 103.58 12.57<br />

KGLS77 GLS7-7 6-7/8 specify 5 12 6-7/8 6 WS3 6 WS3 -- -- -- -- -- -- -- -- 29410 2525 130.83 11.23 24705 2120 109.90 9.43<br />

KGLST77 -- -- 6-7/8 specify 6-1/2 12 6-7/8 6 WS3 6 WS3 2 3/4 3 3/4 35245 2525 156.78 11.23 29605 2120 131.69 9.43<br />

KGLS79 GLS7-9 6-7/8 specify 5 12 8-7/8 6 WS3 6 WS3 -- -- -- -- -- -- -- -- 29410 2525 130.83 11.23 24705 2120 109.90 9.43<br />

KGLST79 -- -- 6-7/8 specify 6-1/2 12 8-7/8 6 WS3 6 WS3 2 3/4 3 3/4 37575 2525 167.15 11.23 31565 2120 140.41 9.43<br />

KHGLS7 HGLS7 6-7/8 specify 6 12 specify 14 WS3 8 WS3 -- -- -- -- -- -- -- -- 30220 3365 134.43 14.97 25385 2825 112.92 12.57<br />

KHGLST7 -- -- 6-7/8 specify 6-1/2 14 specify 14 WS3 8 WS3 2 3/4 3 3/4 34250 3365 152.36 14.97 28770 2825 127.98 12.57<br />

KHGLS9 HGLS9 8-7/8 specify 6 12 specify 14 WS3 8 WS3 -- -- -- -- -- -- -- -- 30220 3365 134.43 14.97 25385 2825 112.92 12.57<br />

KHGLST9 -- -- 8-7/8 specify 6-1/2 16 specify 14 WS3 8 WS3 2 3/4 3 3/4 38280 3365 170.28 14.97 32155 2825 143.04 12.57<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Factored resistances and fastener schedules apply to each side of the saddled hanger.<br />

<br />

4) <strong>Hangers</strong> with seismic straps may require a minimum joist depth. Consult <strong>USP</strong> for additional information.<br />

<br />

6) The bearing loads are based on 560 psi.<br />

7) "Specify" denotes the required supported beam height that must be specified at time of ordering.<br />

Joist<br />

Header<br />

Bolts<br />

Joist<br />

DF-L (Lbs)<br />

Factored Resistance 2,6<br />

DF-L (kN)<br />

S-P-F (Lbs)<br />

S-P-F (kN)<br />

See Welded Installation<br />

chart on page 213<br />

KGLS & KHGLS Specialty Options Chart – refer to Specialty Options pages 210 and 212 for additional details.<br />

150<br />

Option Skewed 1 Sloped Seat 2 Sloped / Skewed 1,2 Sloped Top Flange 3 Top Flange Offset Saddle<br />

Range <br />

<br />

<br />

<br />

Factored <br />

<br />

<br />

KHGLS - may not<br />

<br />

Resistance <br />

<br />

<br />

be sloped/skewed. <br />

<br />

<br />

SK, SL, <br />

<br />

SA, <br />

Ordering<br />

(R) (L), (U) (D), <br />

<br />

<br />

<br />

<br />

<br />

<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Truss & Rafter Tiedowns<br />

Moisture Barrier Plates . . . . . . . .Page 152<br />

• NOP<br />

Protects bottom chord of trusses from moisture damage.<br />

NOP<br />

Embedded Truss Anchors . . . . . .Page 152<br />

• LPTA<br />

Low profile truss anchors provide uplift and lateral<br />

load resistance.<br />

LPTA<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Uplift Girder Ties . . . . . . . . . . . . .Page 153<br />

• RFUS<br />

Retrofit truss anchor installed mechanically fastens into the face of<br />

masonry or concrete.<br />

• RUSC<br />

Retrofit Strap Connector provides a wood-to-wood uplift<br />

connection with WS Wood Screws.<br />

Girder Tiedowns . . . . . . . .Pages 154-156<br />

• LUGT Series<br />

Light capacity girder truss anchor nails to the truss/rafter and the stud.<br />

Can also be used for masonry applications.<br />

• MUGT15<br />

Medium capacity girder truss anchor wraps over the top chord and<br />

bolts to the concrete or tension tie.<br />

• HUGT Series<br />

Heavy capacity girder truss anchor installs over the top chord and<br />

bolts to the concrete or tension tie.<br />

RFUS RUSC<br />

LUGT MUGT15 HUGT<br />

Truss & Rafter<br />

MASONRY UPLIFT CONNECTORS . . .PAGE 157<br />

• SHA Series<br />

Heavy capacity uplift connector bolts both to the truss and masonry.<br />

SHA<br />

Hurricane Gusset<br />

Angles . . . . . . . . . . . . . . . . . . . . . . .Page 158<br />

• HGA Series<br />

Connects gable trusses to top plates.<br />

HGA<br />

Hurricane Retro-Fit<br />

Connector . . . . . . . . . . . . . . . . . . .Page 159<br />

• RT16M<br />

Retrofit connector for trusses installed on top plates.<br />

RT16M<br />

Rafter Ties . . . . . . . . . . . . .Pages 160-162<br />

• HC520, HCPRS, HHCP2, LFTA6, & RT Series<br />

Top plate to truss anchors.<br />

RT15 RT7 HCPRS HHCP2 LFTA6<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 151<br />

<strong>USP</strong>2240-131


Moisture Barrier Plates – NOP series<br />

Moisture Barrier Plates protect the bottom chords<br />

of trusses from moisture damage caused by direct<br />

contact with concrete. These plates eliminate the<br />

need for more expensive treated wood plates.<br />

W<br />

L<br />

Truss & Rafter<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes,<br />

page 10.<br />

• Pre-attach to truss bottom chord or rafter using<br />

prepunched prongs and/or 6d common nails to<br />

prevent wood-to-concrete contact.<br />

<strong>USP</strong><br />

Steel<br />

Dimensions Fastener Schedule 1,2<br />

Size Stock No. Ref. No. Gauge W L Qty Type<br />

NOP2X TSS2, TBP8 26 1-7/16 8 -- -- -- --<br />

2x<br />

NOP1 -- -- 22 1-1/2 8 2 6d<br />

4x NOP4 TSS2-2 26 3-1/2 8 2 6d<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) NAILS<br />

W<br />

NOP1<br />

L<br />

NOP2X<br />

NOP4<br />

W<br />

Typical NOP4<br />

installation<br />

NOP4<br />

L<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Embedded Truss Anchors – LPTA<br />

Low profile design attaches to 2 x 4 or larger bottom chords and<br />

provides uplift and lateral load resistance.<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

F 1<br />

Uplift<br />

F 2<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Embed LPTA 4˝ into concrete tie beam or masonry bond<br />

beam.<br />

• Anchors should be spaced no closer than 8˝ centre-to-centre.<br />

• Moisture barrier may be required.<br />

Typical LPTA installation<br />

W<br />

Dimensions (in)<br />

Fastener Schedule<br />

Factored Resistance (115%) 1<br />

<strong>USP</strong><br />

Steel<br />

Min<br />

DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Stock No. Ref. No. Gauge W H Qty 2 Type 3,4 Uplift F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift F1 F2<br />

LPTA LTA2 18 5 8-1/4 10 10d x 1-1/2 1555 1005 1865 6.92 4.47 8.30 1555 1005 1865 6.92 4.47 8.30<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other<br />

load durations in accordance with the code.<br />

2) Minimum quantity of fasteners to be installed. Product may have additional nail holes not needed to meet<br />

published factored resistance of product.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) NAILS<br />

1 7 /16˝<br />

LPTA<br />

H<br />

1 3 /4˝<br />

152<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Uplift Girder Tie – RFUS<br />

The RFUS is a multi-purpose engineered solution for attaching trusses to concrete<br />

or masonry walls. Wedgebolt fastening eliminates mislocated cast-in-place<br />

anchor bolts and allows retrofit installations. Works with heel heights up to 14˝.<br />

Materials: 10 gauge<br />

Finish: <strong>USP</strong> primer<br />

Codes: Load values are derived from data submitted to various North<br />

American building code evaluators.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Installation:<br />

• Always install in pairs.<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Designer shall be responsible for design of masonry structure, including<br />

any required reinforcement.<br />

• For 1 ply applications, add filler block. Refer to page 182 for wood filler<br />

block installation.<br />

• Moisture barrier may be required.<br />

Fastener Schedule 3,5<br />

Factored Uplift Resistance (115%) 1<br />

<strong>USP</strong><br />

Steel No. of Rafter/Truss 7 Concrete/Masonry 2,4 DF-L<br />

S-P-F<br />

Stock No. Ref. No. Gauge Plys 6<br />

Qty Type Qty Type Lbs kN Lbs kN<br />

RFUS FGTR 10 2 Ply > 12 WS3 4 25.31 4780 <br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

5 1 /2˝<br />

Typical RFUS<br />

installation<br />

5˝<br />

4˝<br />

RFUS<br />

30 1 /2˝<br />

Truss & Rafter<br />

Retrofit Strap Connector – RUSC<br />

The RUSC Retro Uplift Strap Connector provides a wood-to-wood uplift<br />

connection attaching trusses with a 2 x 4 bottom chord to a double stud in<br />

the wall below. WS3 Wood Screws are utilized for fast installation. The<br />

connector can be installed after roof sheathing has been installed.<br />

Materials: 10 gauge<br />

Finish: <strong>USP</strong> primer<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• The RUSC should be installed in pairs.<br />

• Install on minimum 2 ply with equal wall studs centred directly below.<br />

• Works with 2 x 4 bottom chord member and 2 x 4 wall studs.<br />

3 1 /2˝<br />

Fastener Schedule 3,4 Factored Uplift Resistance (115%) 1,2<br />

DF-L<br />

S-P-F<br />

<strong>USP</strong><br />

Steel No, of Rafter/Truss Stud<br />

Stock No. Ref. No. Gauge Plies 5 Qty Type Qty Type Lbs kN Lbs kN<br />

RUSC -- -- 10 2 Ply or greater 16 WS3 16 WS3 6250 27.80 5410 24.07<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake;<br />

no further increase is allowed.<br />

2) Designer must specify stud or post to resist published load values.<br />

<br />

4) Fastener schedule is for two straps used together. The RUSC shall be installed in pairs with a<br />

3 1 /8˝<br />

minimum 2 ply truss and wall stud attachment.<br />

5) Truss plies shall be fastened together to act as a unit.<br />

3 1 /8˝<br />

Typical RUSC<br />

installation<br />

7˝<br />

22 3 /4˝<br />

RUSC<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 153<br />

<strong>USP</strong>2240-131


Girder Tiedowns – LUGT series<br />

Truss & Rafter<br />

The LUGT series is an extremely adaptable tiedown for girder trusses and offers several installation options to<br />

accommodate different framing conditions. It is an ideal retrofit solution to reinforce truss connections to transfer<br />

high wind loads to supporting walls and can be used on either wood framed, concrete or CMU block walls.<br />

LUGT1 – is designed for wood framed walls.<br />

LUGTC2 – is designed for corner hip trusses on wood framed walls.<br />

LUGT2, LUGT3 & LUGT4 – are designed for wood frame, concrete or CMU block walls.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Codes: Factored resistances are derived from data submitted to various North American building code<br />

evaluators and are in accordance with CSA O86-09.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• All nail holes must be filled with specified nails to achieve<br />

loads listed in the chart. Large holes are for concrete/<br />

masonry installations and do not need to be filled<br />

when used for girder-to-stud applications.<br />

• WS Wood Screws included with LUGT3 and LUGT4.<br />

• For concrete and masonry applications, a moisture<br />

barrier may be required, check local building code.<br />

Uplift<br />

F 1<br />

Uplift<br />

Typical LUGT2<br />

installation<br />

F 1<br />

Uplift<br />

NEW<br />

SIZES<br />

F2<br />

Typical LUGT3<br />

installation<br />

(LUGT4 similar)<br />

Uplift<br />

F1<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

F1 F2<br />

F2<br />

Typical LUGT1<br />

installation<br />

Typical LUGTC2<br />

installation<br />

F 2<br />

3 1/4˝<br />

Typical LUGT2<br />

masonry installation<br />

Typical LUGT4<br />

masonry installation<br />

(LUGT3 similar)<br />

3 3/16˝<br />

14 13/16˝<br />

12 7/8˝<br />

154<br />

<strong>USP</strong><br />

Stock No.<br />

LUGT1<br />

LUGTC2<br />

3"<br />

LUGT2<br />

LUGT3<br />

Fastener Schedule 3,7,8,9,10<br />

Factored Resistance (115%) 1,2<br />

No.<br />

S-P-F (Lbs)<br />

Steel of<br />

Rafter/Truss Plate<br />

Stud 4,5,6 DF-L (Lbs) DF-L (kN)<br />

S-P-F (kN)<br />

Ref. No. Gauge Plies Qty Type Qty Type Qty Type F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift<br />

LUGT1 H10S 16 1 8 8d x 1-1/2 8 8d x 1-1/2 7 8d x 1-1/2 1045 495 1580 4.65 2.20 7.03 900 425 1455 4.00 1.89 6.47<br />

LUGT2 LGT2 14 2 16 10d 2 10d 14 10d 1050 455 2340 4.67 2.02 10.41 905 390 2010 4.03 1.73 8.94<br />

LUGTC2 -- -- 14 2 16 10d 2 10d 14 10d -- -- 595 2340 -- -- 2.65 10.41 -- -- 510 2010 -- -- 2.27 8.94<br />

LUGT3 LGT3-SDS2.5 12 3 12 WS25 4 16d Sinker 24 16d Sinker 3155 1415 6025 14.03 6.29 26.80 2705 1215 5945 12.03 5.4 26.45<br />

LUGT4 LGT4-SDS3 12 4 16 WS3 5 16d Sinker 32 16d Sinker -- -- -- -- 8340 -- -- -- -- 37.10 -- -- -- -- 7150 -- -- -- -- 31.81<br />

Concrete or Masonry Application<br />

LUGT2 LGT2 14 2 16 10d -- -- -- -- 5 1/4WB 1265 475 1915 5.63 2.11 8.52 1085 410 1645 4.83 1.82 7.32<br />

LUGT3 LGT3-SDS2.5 12 3 12 WS25 -- -- -- -- 4 3/8WB -- -- -- -- 5330 -- -- -- -- 23.71 -- -- -- -- 5260 -- -- -- -- 23.40<br />

LUGT4 LGT4-SDS3 12 4 16 WS3 -- -- -- -- 4 3/8WB -- -- -- -- 6185 -- -- -- -- 27.51 -- -- -- -- 5300 -- -- -- -- 23.58<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Factored resistances apply where roof pitch is between 3:12 and 8:12.<br />

3) Additional anchorage products to be designed by others.<br />

4) 1/4WB denotes a 1/4" x 3" Powers "Wedge Bolt" or equivalent installed in a predrilled hole. Refer to manufacturer's literature for further information.<br />

5) 3/8WB denotes a 3/8" x 5" Powers "Wedge Bolt" or equivalent installed in a predrilled hole. Refer to manufacturer's literature for further information.<br />

6) Fasteners must be installed in fully grouted and reinforced concrete masonry (f'm = 1500 psi) or reinforced concrete (f'c = 2500 psi).<br />

7) Minimum nail embedment shall be 8 nail diameters (typ).<br />

8) For proper installation, the number of studs must be equal-to or greater-than the number of roof truss plies.<br />

9) Wedge Bolts are not supplied with the LUGT2, LUGT3 or LUGT4.<br />

10) NAILS: 8d x 1-1/2 are 0.131" dia. x 1-1/2" long, 10d nails are 0.148" dia. x 3" long, 16d Sinkers are 0.148" dia. x 3-1/4" long,<br />

WS25 Wood Screws are 1/4" dia. x 2-1/2" long (supplied with LUGT3) and WS3 Wood Screws are 1/4" dia. x 3" long (supplied with LUGT4).<br />

New products or updated product information are designated in red font.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

LUGT4


Girder Tiedowns – MUGT series<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Designed for higher uplift resistance for wood frame<br />

and concrete block construction. The MUGT15 can accommodate<br />

variable truss bearing depths.<br />

Materials: 12 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• When straps are wrapped over the truss, install nails in backside of truss.<br />

See MUGT15 installation diagram for minimum nail requirements into the<br />

face and on top of the truss.<br />

• If installed straight-up with no wrap over the top of the truss, fill all nail<br />

holes.<br />

• Moisture barrier may be required.<br />

Install a minimum<br />

of (6) 10d nails<br />

into the face<br />

MUGT15<br />

5/8" Bolt<br />

Typical MUGT15<br />

to support beam<br />

installation<br />

Install a minimum<br />

of (12) 10d nails<br />

into back<br />

Install a minimum<br />

of (4) 10d nails<br />

into the top<br />

1 1/4"<br />

Min 3" x 3" x 1/4"<br />

Bearing Plate<br />

Install a minimum<br />

of (4) 10d nails<br />

into the top<br />

Support Beam<br />

Designed<br />

By Others<br />

Truss & Rafter<br />

14 5 /8˝<br />

Install a minimum<br />

of (6) 10d nails<br />

into the face<br />

1 1/4˝<br />

PHD4A<br />

page 41<br />

1 1 /4˝<br />

3 11 /16˝<br />

MUGT15<br />

2 7 /16˝<br />

Typical MUGT15<br />

wood installation<br />

with PHD4A<br />

Fastener Schedule 2<br />

Anchor Bolt Rafter/Truss 3,5 DF-L S-P-F<br />

<strong>USP</strong><br />

Steel Mounting<br />

Top Face Back<br />

Stock No. Ref. No. Gauge Condition Qty Dia. Qty Qty Qty Type Lbs kN Lbs kN<br />

MUGT15 MGT 12<br />

Face-Max 1 5/8 -- -- 28 -- -- 10d 4650 20.69 4000 17.79<br />

Top-Min 1 5/8 4 6 12 10d 4320 19.22 3715 16.53<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake;<br />

reduce for other load durations in accordance with the code.<br />

2) Additional anchorage products to be designed by others.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

4) Designer must specify anchor bolt type, length, and embedment.<br />

5) NAILS<br />

Factored Uplift Resistance (115%) 1<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 155<br />

<strong>USP</strong>2240-131


Girder Tiedowns – HUGT series<br />

The HUGT series high uplift girder tiedowns can be installed on<br />

beams and top chords of trusses with slopes from 0° to 34°.<br />

Truss & Rafter<br />

Materials: 7 gauge<br />

Finish: <strong>USP</strong> primer<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Install the HUGT over the beam or truss (see “W” dimension<br />

on chart for appropriate width).<br />

• Install (4) LBP58-TZ washers if (2) 5/8˝ tension bolts are<br />

used (wood installation) or (2) 3/4˝ dia. washers if a 3/4˝ dia.<br />

anchor bolt is used (concrete installation).<br />

• Attached members shall be designed to resist applied loads.<br />

• Moisture barrier may be required.<br />

Concrete Installation<br />

(2) 3 /4˝ washers are<br />

required if 3 /4˝ dia. bolt is<br />

used (washer not included)<br />

Wood Installation<br />

(4) LBP58-TZ washers<br />

are required if 5 /8˝ dia.<br />

bolt is used (washer not<br />

included) see chart on<br />

this page<br />

HTT5<br />

(not included)<br />

see page 45<br />

Typical HUGT3<br />

wood-to-wood<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Typical HUGT2<br />

wood-to-concrete<br />

installation<br />

2 7 /8˝<br />

4˝<br />

W<br />

2 3 /16˝<br />

HUGT<br />

<strong>USP</strong><br />

Stock No.<br />

HUGT2<br />

HUGT3<br />

HUGT4<br />

Fastener Schedule 3<br />

Factored Uplift Resistance (115%) 1,2<br />

O.C. Dim<br />

W<br />

Anchor Washers Threaded Rod DF-L<br />

S-P-F<br />

Steel<br />

Between Installation<br />

Girder 4,6<br />

Ref. No. Gauge (in) Anchors (in) Type Qty Type Qty Dia. Qty Type Lbs kN Lbs kN<br />

HGT-2<br />

HGT-3<br />

HGT-4<br />

7<br />

7<br />

7<br />

3-5/16<br />

4-15/16<br />

6-7/8<br />

5-3/4<br />

7-3/8<br />

9<br />

Wood<br />

Wood<br />

Wood<br />

4<br />

4<br />

4<br />

LBP58-TZ<br />

LBP58-TZ<br />

LBP58-TZ<br />

2<br />

2<br />

2<br />

5/8<br />

5/8<br />

5/8<br />

Concrete<br />

Concrete<br />

Concrete<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

2<br />

2<br />

2<br />

3/4<br />

3/4<br />

3/4<br />

8<br />

8<br />

8<br />

10d<br />

10d<br />

10d<br />

18575<br />

18575<br />

18575<br />

82.63<br />

82.63<br />

82.63<br />

9365<br />

9365<br />

9365<br />

41.66<br />

41.66<br />

41.66<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Factored resistances apply where roof pitch is between 3:12 and 8:12.<br />

3) Additional anchorage products to be designed by others.<br />

4) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

5) Designer must specify anchor bolt type, length, and embedment.<br />

6) NAILS<br />

156<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Masonry Uplift <strong>Connectors</strong> – SHA series<br />

Connects trusses directly to masonry or concrete and features slotted<br />

base holes to ease installation.<br />

Materials: Angle – 3 gauge; Gussets – 10 gauge<br />

Finish: <strong>USP</strong> primer<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Uplift<br />

F 1<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Bolts must be ordered seperately.<br />

• Install directly flush to masonry wall.<br />

• The SHA series connectors shall be installed in pairs.<br />

• Moisture barrier may be required.<br />

NEW<br />

Typical SHA6<br />

installation<br />

1 1 /2˝<br />

6˝<br />

3 1 /4˝<br />

4 1 /4˝<br />

2 1 /4˝<br />

Typical SHA6T<br />

installation<br />

1 1 /2˝<br />

6˝<br />

13 3 /4˝<br />

12 3 /4˝<br />

2 1 /2˝<br />

Truss & Rafter<br />

2 1 /4˝<br />

2 1 /2˝<br />

SHA6<br />

SHA6T<br />

Fastener Schedule 3 Factored Resistance (Lbs.) 1,2<br />

<strong>USP</strong><br />

Stock No.<br />

Concrete Wall Rafter/Truss 7<br />

Anchor Bolts 4,5,8<br />

No.<br />

Ref. No. Qty Dia. Qty Dia. of Plies 6 Unit<br />

SHA6 4 1/2 2 3/4<br />

SHA6T 4 1/2 2 3/4<br />

2 Ply<br />

3 Ply or ><br />

2 Ply<br />

3 Ply or ><br />

1) Factored resistances have been increased 15% for wind or seismic loads;<br />

no further increase shall be permitted.<br />

2) Factored resistances are for a pair of SHA devices. SHA's shall be installed in pairs.<br />

3) Fastener schedule is for a pair of SHA devices.<br />

<br />

5) Concrete compressive strength shall be 2500 psi or greater at 28 days.<br />

6) Multiple ply truss shall be fastened together to act as a single unit.<br />

<br />

<br />

New products or updated product information are designated in red font.<br />

DF-L<br />

Uplift<br />

S-P-F<br />

Uplift<br />

115% 115%<br />

Lbs 2500 2500<br />

kN 11.12 11.12<br />

Lbs 3750 3750<br />

kN 16.68 16.68<br />

Lbs 11180 8825<br />

kN 49.73 39.26<br />

Lbs 12600 8945<br />

kN 56.05 39.79<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 157<br />

<strong>USP</strong>2240-131


Hurricane Gusset Angles – HGA series<br />

Designed for attaching gable end trusses to wood top<br />

plates and masonry walls.<br />

Truss & Rafter<br />

HGA10 – Versatile wood-to-wood connector that<br />

satisfies high wind and seismic loading requirements.<br />

HGAM10 – For installation into grouted concrete tie<br />

beam or masonry bond beam. Provides lateral and<br />

uplift resistance.<br />

Materials: 14 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• HGAM10 – Install <strong>USP</strong>’s WS15 Wood Screws into<br />

the truss and drill holes for wedge bolts. Install wedge<br />

bolts into concrete block per manufacturer’s<br />

recommendation.<br />

• HGA10 – Install with <strong>USP</strong>’s WS3 Wood Screws into<br />

top plate, and WS15 Wood Screws into the truss.<br />

• WS Wood Screws are included with HGA10 angles.<br />

• WS Wood Screws and Wedge bolts are included with<br />

HGAM10 angles.<br />

• Moisture barrier may be required.<br />

Uplift<br />

F 1<br />

F 3<br />

F 2<br />

Typical HGA10 installation<br />

Embossed<br />

gussets improve<br />

lateral load<br />

resistance<br />

3 1 /2˝<br />

F 1<br />

Moisture barrier<br />

not shown<br />

3˝<br />

Typical HGAM10 installation<br />

Embossed<br />

gussets improve<br />

lateral load<br />

resistance<br />

3 1 /2˝<br />

3˝<br />

F2<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

HGA10<br />

2˝<br />

HGAM10<br />

2 7/8˝<br />

Fastener Schedule 2<br />

Factored Resistance (115%) 1<br />

Rafter/Truss Plate 3 DF-L (Lbs) DF-L (kN)<br />

S-P-F (Lbs) S-P-F (kN)<br />

<strong>USP</strong><br />

Steel<br />

Stock No. Ref. No. Gauge Qty Type Qty Type F1 F2 F3 Uplift F1 F2 F3 Uplift F1 F2 F3 Uplift F1 F2 F3 Uplift<br />

HGA10KT HGA10KT 14 4 WS15 4 WS3 1365 1620 865 1330 6.07 7.21 3.85 5.92 1175 1395 745 1145 5.23 6.21 3.31 5.09<br />

HGAM10KT HGAM10KTA 14 4 WS15 4 1/4 1115 1150 765 945 4.96 5.12 3.40 4.20 955 990 660 815 4.25 4.40 2.94 3.63<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase is allowed.<br />

<br />

<br />

Refer to manufacturer's literature for further information.<br />

158<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Hurricane Retrofit Connector – RT16M<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Designed as a retrofit connector for trusses installed on top plates. Can also be<br />

used as a holdown for a roof or floor system.<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Tapcon® Concrete Screws are not supplied with RT16M<br />

connector.<br />

• Install Tapcon® Concrete Screws in lower two holes for<br />

Single Top Plate or Conventional Raised Foundation or<br />

Modular Home Installations.<br />

• Moisture barrier may be required.<br />

F 1<br />

Uplift<br />

Typical RT16M<br />

top plate<br />

installation<br />

8 15 /16˝<br />

3 1 /2˝<br />

5˝<br />

1 9 /16˝<br />

F 2<br />

F3<br />

Truss & Rafter<br />

RT16M<br />

<strong>USP</strong><br />

Stock No.<br />

RT16M<br />

Fastener Schedule 2,3,4,5<br />

Steel<br />

Truss/Rafter Top Plate Masonry Block<br />

DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Ref. No. Gauge Qty Type Qty Type Qty Type Uplift F1 F2 F3 Uplift F1 F2 F3 Uplift F1 F2 F3 Uplift F1 F2 F3<br />

9 10d x 1-1/2 -- -- -- -- 4 1/4" x 1-3/4" Tapcon 1730 1045 795 190 7.70 4.65 3.54 0.85 1470 1045 795 190 6.54 4.65 3.54 0.85<br />

HM9KT 18<br />

9 10d x 1-1/2 4 16d 2 1/4" x 1-3/4" Tapcon 1690 -- -- -- -- -- -- 7.52 -- -- -- -- -- -- 1470 -- -- -- -- -- -- 6.54 -- -- -- -- -- --<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase is allowed.<br />

2) Install with 1/4" x 1-3/4" Tapcon® Concrete Screws in accordance to manufacturer's installation specifications.<br />

3) Fasteners to be installed to fully grouted and reinforced concrete masonry.<br />

4) Minimum nail embedment shall be 8 nail diameters (typ).<br />

5) Nails:<br />

Factored Resistance (115%) 1<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 159<br />

<strong>USP</strong>2240-131


Rafter Ties – HC520, HCPRS, HHCP2, LFTA6 & RT series<br />

These anchors tie trusses and rafters to top plates and may be used to tie wood<br />

framing members to resist uplift and lateral forces.<br />

Truss & Rafter<br />

Materials: See chart<br />

Finish: G90 galvanizing; RT7A-GC & RT15-GC – Gold Coat<br />

Options: HHCP2, LFTA6, RT3A, RT4, RT5, RT7, RT7A, RT10, RT15, RT8A,<br />

RT16A, RT16-2, & RT20 are available in Triple Zinc. To order, add TZ<br />

to stock number, as in RT10-TZ.<br />

RT3A, RT4, RT5, RT7, RT8A, RT10,RT16A, and RT16-2 are<br />

available in Stainless Steel. To order, add SS to stock number,<br />

as in RT7-SS.<br />

Codes: Load values are derived from data submitted to various North<br />

American building code evaluators.<br />

Typical LFTA6<br />

installation<br />

Typical HCPRS<br />

installation<br />

Typical HC520<br />

installation<br />

Typical HC520<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

1 9 /16˝<br />

1 5 /8˝<br />

8 3/8˝<br />

19 1/8˝<br />

4 ¼˝<br />

2˝<br />

6 1/2˝ 2 1/4˝<br />

LFTA6<br />

5 1 /4˝<br />

HCPRS<br />

4˝<br />

HC520<br />

1 1 /2˝<br />

Uplift<br />

F 1<br />

Uplift<br />

F1<br />

F2<br />

Typical HHCP2<br />

installation<br />

Typical HHCP4-TZ<br />

installation<br />

Typical RT3A<br />

installation<br />

Typical RT4<br />

installation<br />

Typical RT5<br />

installation<br />

1 5 /8˝<br />

6 5 /8˝<br />

NEW<br />

4⁷∕₈˝<br />

6⁵∕₈˝<br />

1 7 /16˝<br />

1 1 /2˝<br />

1 7 /8˝<br />

1 7 /8˝<br />

HHCP2<br />

3˝<br />

HHCP4-TZ<br />

3˝<br />

4 1 /2˝<br />

1 1 /2˝<br />

RT3A<br />

2˝<br />

RT4<br />

1 1 /4˝<br />

3 3 /4˝<br />

1 15 /16˝<br />

RT5<br />

5 1 /4˝<br />

2 7 /8˝<br />

160 1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

continued on next page


Rafter Ties – HC520, HCPRS, HHCP2, LFTA6 & RT series cont.<br />

F 1<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Typical RT6<br />

installation<br />

2 1 /2˝<br />

1 3 /8˝<br />

RT6<br />

1 9 /16˝<br />

3 9 /16˝<br />

Typical RT7<br />

installation<br />

5 1 /4˝<br />

1 3 /8˝<br />

2 15 /16˝<br />

1 9 /16˝<br />

RT7<br />

F2<br />

Typical RT7A<br />

installation<br />

6 1 /2˝<br />

1 1 /2˝<br />

4˝<br />

2 7 /16˝<br />

RT7A<br />

1 1 /2˝<br />

Typical RT8A<br />

installation<br />

4 15 /16˝<br />

7 13 /16˝<br />

1 1 /4˝<br />

1 1 /4˝<br />

RT8A<br />

Typical RT10<br />

installation<br />

2 3 /8˝<br />

3 1 /16˝<br />

10 3 /4˝<br />

1 9 /16˝<br />

RT10<br />

Truss & Rafter<br />

Uplift<br />

F1<br />

F2<br />

Typical RT15<br />

installation<br />

Typical RT16A<br />

installation<br />

Typical RT16AR<br />

installation<br />

Typical RT16-2<br />

installation<br />

Typical RT20<br />

installation<br />

1 9 /16˝<br />

3 1 /2˝<br />

5˝<br />

1 9 /16˝<br />

NEW<br />

3 3 /8˝<br />

5 1 /2˝<br />

2 1 /16˝<br />

3 1 /2˝<br />

6 1 /2˝<br />

3 1 /8˝<br />

2 1 /4˝<br />

4 5 /8˝<br />

2 5 /8˝<br />

6 1 /2˝<br />

6 1 /2˝<br />

6 1 /2˝<br />

4 1 /4˝<br />

21 1 /8˝<br />

5 1 /4˝<br />

RT15<br />

RT16A<br />

RT16AR<br />

RT16-2<br />

RT20<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 161<br />

<strong>USP</strong>2240-131


Rafter Ties – HC520, HCPRS, HHCP2, LFTA6 & RT series cont.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• All nail holes must be filled with specified nails to achieve loads listed in the chart. For substituting<br />

with different nail sizes, refer to “Optional Nails” chart on page 15 or consult a design professional.<br />

• Depending on pitch, birdsmouth notching may be required with some models to enable installers to<br />

fill all nail holes. Consult a design professional for appropriate notching.<br />

• Designer shall determine if solid blocking is required.<br />

Truss & Rafter<br />

Fastener Schedule 3<br />

Factored Resistance (115%) 1<br />

<strong>USP</strong><br />

Steel<br />

Truss/Rafter Plate Stud<br />

DF-L (Lbs)<br />

DF-L (kN)<br />

S-P-F (Lbs)<br />

S-P-F (kN)<br />

Stock No. Ref. No. Gauge Qty Type Qty Type Qty Type F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift<br />

RT3A<br />

H3,<br />

S/H3<br />

18 4 8d 4 8d -- -- -- -- 310 310 1190 1.38 1.38 5.29 265 265 1020 1.18 1.18 4.54<br />

RT4 H4 18 4 8d 4 8d -- -- -- -- 350 350 760 1.56 1.56 3.38 300 300 650 1.33 1.33 2.89<br />

RT5 H5 18 4 8d 4 8d -- -- -- -- 425 425 995 1.89 1.89 4.43 365 365 855 1.62 1.62 3.80<br />

RT6 HS24 18 8 10d x 1-1/2 6 10d x 1-1/2 -- -- -- -- 1310 1310 1070 5.83 5.83 4.76 1125 1125 915 5.00 5.00 4.07<br />

H2.5,<br />

RT7 H2.5T, 18 5 8d 5 8d -- -- -- -- 315 315 940 1.40 1.40 4.18 270 270 805 1.20 1.20 3.58<br />

S/H2.5<br />

RT7A H2.5A 18 5 8d 5 8d -- -- -- -- 345 345 1235 1.53 1.53 5.49 295 295 1060 1.31 1.31 4.72<br />

RT7A-GC -- -- 18 5 N8-GC 5 N8-GC -- -- -- -- 345 345 1235 1.53 1.53 5.49 295 295 1060 1.31 1.31 4.72<br />

LFTA6 2 H6, TSP 16 8 8d 8 8d -- -- -- -- 870 -- -- 1265 3.87 -- -- 5.63 775 -- -- 1075 3.45 -- -- 4.78<br />

RT8A H8 18 5 10d x 1-1/2 5 10d x 1-1/2 -- -- -- -- 350 350 1430 1.56 1.56 6.36 300 300 1225 1.33 1.33 5.45<br />

RT10<br />

H2, H2A,<br />

S/H2<br />

18 6 8d 8 8d 6 8d 315 315 940 1.40 1.40 4.18 270 270 805 1.20 1.20 3.58<br />

RT15 H1 18 5 8d x 1-1/2 5 8d -- -- -- -- 925 485 975 4.11 2.16 4.34 795 415 835 3.54 1.85 3.71<br />

RT15-GC -- -- 18 5 N8-GC 5 N8-GC -- -- -- -- 910 475 960 4.05 2.11 4.27 770 400 805 3.43 1.78 3.58<br />

RT16A<br />

H10,<br />

H10A, 18 9 10d x 1-1/2 8 10d -- -- -- -- 1285 1195 2545 5.72 5.32 11.32 1100 1025 2180 4.89 4.56 9.70<br />

H14<br />

RT16AR H10AR 18 9 10d x 1-1/2 8 10d -- -- -- -- 1285 1195 2545 5.72 5.32 11.32 1100 1025 2180 4.89 4.56 9.70<br />

RT16-2 H10-2 18 8 8d 8 8d -- -- -- -- 1050 675 1860 4.67 3.00 8.27 900 580 1595 4.00 2.58 7.09<br />

HHCP2 HCP2 18 10 10d x 1-1/2 10 10d x 1-1/2 -- -- -- -- 710 -- -- 1505 3.16 -- -- 6.69 505 -- -- 1070 2.25 -- -- 4.76<br />

HHCP4-TZ HCP4, HCP4Z 16 8 10d 8 10d -- -- -- -- 690 -- -- 1835 3.07 -- -- 8.16 590 -- -- 1575 2.62 -- -- 7.01<br />

HC520 GBC 18 -- -- -- -- 11 8d 6 8d 510 560 640 2.27 2.49 2.85 440 485 555 1.96 2.16 2.47<br />

HCPRS -- -- 18 -- -- -- -- 5 8d 6 8d x 1-1/2 945 340 1020 4.20 1.51 4.54 665 240 660 2.96 1.07 2.94<br />

RT20 -- -- 16 9 10d x 1-1/2 4 10d 9 10d x 1-1/2 -- -- -- -- 1925 -- -- -- -- 8.56 -- -- -- -- 1650 -- -- -- -- 7.34<br />

1) 15% increase for short-term loads such as wind and earthquake has been taken into account for factored resistances, no further increase allowed.<br />

2) LFTA6: To achieve F1 lateral loads, three nails must be installed on each side on the strap located closest to the bend line.<br />

Lateral F1 load direction does not apply to roof truss-to-top plate installations.<br />

3) NAILS:<br />

red font.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Anchor installation to achieve twice the load<br />

(using two identical connectors)<br />

Wall Top Plate<br />

Install diagonally across from each<br />

other for minimum 1-1/2˝ truss/rafter<br />

(Top View)<br />

Nailing into both sides of a single ply 2x<br />

truss/rafter may cause damages in the<br />

wood<br />

162<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Plated Truss<br />

Truss <strong>Hangers</strong> . . . . . . . . . .Pages 165-169<br />

• THD Series<br />

Medium-to-heavy capacity face mount hanger.<br />

• THDS Series<br />

Medium capacity truss hanger.<br />

• THDH Series<br />

Heavy capacity face mount hanger.<br />

THD<br />

THDS<br />

THDH<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

• MUS & HUS Series<br />

Medium capacity face mount hanger with double shear nailing.<br />

• MSH Series<br />

Field adjustable top or face mount strap hanger.<br />

Skewed Truss <strong>Hangers</strong> . .Pages 170-171<br />

• MSHL/R Series<br />

Skewed 45° floor truss hanger.<br />

• MSSH Series<br />

Severely skewed strap hanger for angles 60° to 85°.<br />

• SNP3<br />

Adjustable nail plate for connecting square cut trusses at skews up to<br />

60°.<br />

Hip /Jack <strong>Connectors</strong> . . .Pages 172-173<br />

• BN Series<br />

Face mount hanger for four mono trusses.<br />

• HJC Series<br />

Face mount hanger for one hip and one jack truss.<br />

HUS<br />

MUS similar<br />

MSH213L<br />

left shown<br />

BN<br />

MSSH217R<br />

right shown<br />

HJC<br />

MSH<br />

SNP3<br />

HJHC<br />

Plated Truss<br />

• HTHJ Series<br />

Light capacity face mount hanger for one hip and one jack truss.<br />

• HHC Series<br />

Face mount hanger for two hip trusses.<br />

• HJHC Series<br />

Face mount hanger for two hip and one jack truss.<br />

HHC<br />

HTHJ<br />

Girder Truss <strong>Hangers</strong> . . .Pages 174-176<br />

• GT, GTD, & GTS Series<br />

Girder truss hanger bolts to a supporting truss.<br />

• GTQ & GTQM Series<br />

Girder truss hanger installs with WS screws and offers<br />

min/max fastening options.<br />

• GTWS Series<br />

Girder truss hanger with high uplift capacity screws to a<br />

supporting truss.<br />

Truss Clips . . . . . . . . . . . . .Pages 176-177<br />

• STC Series<br />

A scissor truss clip with slotted nail holes for horizontal movement.<br />

• FTC Series<br />

A floor truss clip to transfer loads between floor truss plies.<br />

GTD<br />

GTQ<br />

GTQM similar<br />

STC<br />

GTS GT<br />

GTWS<br />

FTC<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 163<br />

<strong>USP</strong>2240-131


Plated Truss<br />

Supplemental Bearing Plates . . .Page 178<br />

• SBP Series<br />

Connects to truss at bearing locations to distribute concentrated loads.<br />

SBP<br />

Roof Truss Ties . . . . . . . . . . . . . . .Page 179<br />

• TR Series<br />

Provides lateral support for non-load bearing walls while<br />

allowing floor and roof trusses to deflect.<br />

Plated Truss<br />

• HTC Series<br />

High capacity deflection clip.<br />

Blocking Supports . . . . . . . . . . . .Page 179<br />

• ZC Series<br />

Supports blocking between trusses and joists.<br />

Truss Spacers . . . . . . . . . .Pages 180-181<br />

• The Stabilizer<br />

Truss brace and spacer that connects with prongs.<br />

• TS & TSX Series<br />

Truss spacer that connects with nails.<br />

Drag Strut <strong>Connectors</strong> . . . . . . . .Page 181<br />

• LDSC4/DSC4<br />

Transfers lateral load from a truss to a bearing wall.<br />

Alternate Installations . . . . . . . . .Page 182<br />

TR<br />

ZC<br />

31 - 24<br />

LDSC4L<br />

left shown<br />

HTC<br />

TS<br />

DSC4R<br />

right shown<br />

TSX<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

• Backer block installations<br />

• Panel point installations<br />

• Filler block installations<br />

164<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Heavy-Duty Face Mount Truss <strong>Hangers</strong> – THD series<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Options: THD28-2, THD46, THD48, & THD410 are available in<br />

Triple Zinc. To order, add TZ to stock number, as in<br />

THD28-2TZ.<br />

See Specialty Options Chart. Rough/Full sizes<br />

available. THD hangers with widths greater than 3˝ can<br />

have one flange inverted with no load reduction. Specify<br />

right (R) or left (L).<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

See <strong>EWP</strong> applications page 122<br />

Dimensions (in) Fastener Schedule 2,3<br />

Header Joist<br />

W<br />

THD28<br />

A<br />

D<br />

H<br />

Typical THD210<br />

installation<br />

Joist /<br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Truss Size Stock No. Ref. No. Gauge W H D A Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

2 x 6 - 8 THD26 HTU26 16 1-5/8 5-1/16 3 1-7/8 18 16d 12 10dx1-1/2 5010 4390 22.29 19.53 3557 3117 15.82 13.87<br />

2 x 8 - 10 THD28 HTU28 16 1-5/8 7 3 1-7/8 28 16d 16 10dx1-1/2 6495 4390 28.89 19.53 4611 3117 20.51 13.87<br />

2 x 10 - 12 THD210 HTU210 16 1-5/8 9 3 1-7/8 38 16d 20 10dx1-1/2 8380 5835 37.28 25.96 5950 4143 26.47 18.43<br />

(2) 2 x 6 - 8 THD26-2<br />

HHUS26-2,<br />

HTU26-2<br />

14 3-7/16 5-3/8 3 2 18 16d 12 10d 7090 5745 31.54 25.56 5034 4079 22.39 18.14<br />

(2) 2 x 8 - 10 THD28-2<br />

HHUS28-2,<br />

HTU28-2<br />

14 3-7/16 7-1/8 3 2 28 16d 16 10d 8195 4885 36.45 21.73 5818 3468 25.88 15.43<br />

(2) 2 x 10 - 12 THD210-2<br />

HHUS210-2,<br />

HTU210-2<br />

14 3-7/16 9-1/8 3 2 38 16d 20 10d 11540 7250 51.33 32.25 8193 5148 36.45 22.90<br />

4 x 6 - 8 THD46 HHUS46 14 3-5/8 5-5/16 3 2 18 16d 12 10d 7090 5745 31.54 25.56 5034 4079 22.39 18.14<br />

4 x 8 - 10 THD48 HHUS48 14 3-5/8 7-1/16 3 2 28 16d 16 10d 8195 4885 36.45 21.73 5818 3468 25.88 15.43<br />

4 x 10 -12 THD410 HHUS410 14 3-5/8 9-1/16 3 2 38 16d 20 10d 11540 7250 51.33 32.25 8193 5148 36.45 22.90<br />

4 x 12 - 14 THD412 -- -- 14 3-5/8 11 3 3 48 16d 20 10d 11540 7250 51.33 32.25 8193 5148 36.45 22.90<br />

4 x 14 - 16 THD414 -- -- 14 3-5/8 12-7/8 3 3 58 16d 20 10d 11540 7250 51.33 32.25 8193 5148 36.45 22.90<br />

(3) 2 x 10 - 12 THD210-3 HHUS210-3 12 5-1/8 9 3 3 38 16d 20 10d 11540 7250 51.33 32.25 8193 5148 36.45 22.90<br />

6 x 10 -12 THD610 HHUS5.50/10 12 5-1/2 9 3 3 38 16d 20 10d 12455 6425 55.40 28.58 8843 4562 39.34 20.29<br />

6 x 12 - 14 THD612 -- -- 12 5-1/2 11 3 3 48 16d 20 10d 13785 9850 61.32 43.82 9787 6994 43.54 31.11<br />

6 x 14 - 16 THD614 -- -- 12 5-1/2 12-7/8 3 3 58 16d 20 10d 13785 9850 61.32 43.82 9787 6994 43.54 31.11<br />

7 x 9-1/4 - 14 THD7210 HHUS7.25/10 12 7-1/4 9 3 3 38 16d 20 10d 12455 6425 55.40 28.58 8843 4562 39.34 20.29<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

3) NAILS<br />

Some model designs may<br />

vary from illustration shown<br />

Factored Resistance<br />

DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Plated Truss<br />

Specialty Options Chart – refer to Specialty Options pages 210 to 211 for additional details.<br />

Option Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3 Inverted Flange<br />

<br />

Range<br />

See Sloped Seat and Skewed Widths > 3 can have<br />

one flange inverted.<br />

100% of table value.<br />

Factored<br />

65% of table value when<br />

85% of table value 65% of table value 65% of table value<br />

Resistance<br />

nailing into the support<br />

members end grain.<br />

Ordering<br />

Add SK, angle required,<br />

and right (R) or left (L),<br />

to product number.<br />

Ex. THD410-SK45R<br />

Add SL, slope required,<br />

and up (U) or down (D),<br />

to product number.<br />

Ex. THD410-SL30D<br />

See Sloped Seat and Skewed.<br />

Ex. THD410-SK45RSL30D<br />

Add 1IF, one flange,<br />

right (R) and left (L),<br />

to product number.<br />

Ex. THD4101IFR<br />

Left<br />

flange<br />

W<br />

D<br />

A<br />

H<br />

Right<br />

flange<br />

1) Skewed hangers with skews greater than 15° may have all joist nailing on outside flange.<br />

2) Sloped or sloped / skewed hangers with slopes greater than 15° may have additional joist nails.<br />

3) All sloped, skewed, or combinations require bevel cut on joist in all applications.<br />

THD28-2<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 165<br />

<strong>USP</strong>2240-131


Truss <strong>Hangers</strong> – THDS26<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

A<br />

H<br />

Plated Truss<br />

Dimensions (in)<br />

Application 4<br />

Fastener Schedule 5,6<br />

Factored Resistance<br />

Header Joist 2 S-P-F (Lbs) S-P-F (kN)<br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1<br />

Stock No. Ref. No. Gauge W H D A Header Joist 3 Qty Type Qty Type 100% 115% 100% 115%<br />

(1) 2x6 S-P-F 2x6 S-P-F 18 16d x 2-1/2 10 10d x 1-1/2 2105 1605 9.36 7.14<br />

THDS26 -- -- 18 1-5/8 5-1/8 3-1/2 2-7/16<br />

(2) 2x6 S-P-F 2x6 S-P-F 18 16d x 2-1/2 10 10d x 1-1/2 2330 1605 10.36 7.14<br />

(1) 2x6 S-P-F S-P-F plated truss 18 16d x 2-1/2 10 10d x 1-1/2 3405 1605 15.15 7.14<br />

(2) 2x6 S-P-F S-P-F plated truss 18 16d x 2-1/2 10 10d x 1-1/2 3630 1605 16.15 7.14<br />

1) Calculated using nail resistance values in CSA O86.1-94. Nails considered to be equivalent to toe-nails to end distance.<br />

Uplift values have been increased by 1.15 for short-term loading such as wind.<br />

2) When used in a truss application, the fasteners into the supported member will need to be driven through the truss plate to complete the installation.<br />

<br />

4) Supporting and supported wood members are to be designed by others. Ensure supporting member can accept all fasteners.<br />

5) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

6) NAILS:<br />

New products or updated product information are designated in red font.<br />

Heavy-Duty Truss <strong>Hangers</strong> – THDH series<br />

W<br />

THDS26<br />

D<br />

Typical THDS26<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: 12 gauge<br />

Finish: G90 galvanizing<br />

Options: See Specialty Options Chart.<br />

THDH412 is available in Triple Zinc.<br />

To order, add TZ to stock number,<br />

as in THDH412-TZ.<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes,<br />

page 10.<br />

• Joist nails must be driven in at a 30° to 45° angle<br />

through the joist or truss into the header to achieve<br />

listed loads. Standard length “double shear” nails<br />

must be used to achieve listed load values.<br />

See <strong>EWP</strong> applications page 122<br />

Specialty Options Chart – refer to Specialty Options pages 210 to 211<br />

for additional details.<br />

Option Skewed 1,3 Sloped Seat 2,3 Sloped / Skewed 1,2,3<br />

Range <br />

Factored <br />

<br />

<br />

Resistance <br />

<br />

<br />

Ordering<br />

<br />

<br />

<br />

Drive joist nails into header at 30°<br />

to 45° to achieve listed loads.<br />

W<br />

4˝<br />

THDH<br />

<br />

<br />

<br />

Inverted flange option is not available for THDH models.<br />

2 1 /2˝<br />

H<br />

Typical THDH double<br />

shear installation<br />

Dimple allows<br />

30˚ to 45˚<br />

nailing<br />

Typical THDH26-2<br />

installation<br />

Some model designs<br />

may vary from<br />

illustration shown<br />

W<br />

THDH26-2<br />

2 1 /2˝<br />

D<br />

H<br />

166<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

continued on next page


Heavy-Duty Truss <strong>Hangers</strong> – THDH series continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Joist /<br />

Truss Size<br />

<strong>USP</strong><br />

Stock No.<br />

Dimensions (in)<br />

Fastener Schedule 2,3,4<br />

Slant Nail Truss <strong>Hangers</strong> – MUS & HUS series<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Ref. No. W H D Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

2 x 6 - 8 THDH26 HGUS26 1-5/8 5-7/16 5 20 16d 8 16d 7970 4410 35.45 19.62 5660 3130 25.18 13.92<br />

2 x 8 - 10 THDH28 HGUS28 1-5/8 7-3/16 5 36 16d 12 16d 11860 8230 52.76 36.61 8420 5845 37.46 26.00<br />

2 x 10 - 12 THDH210 -- -- 1-5/8 9-3/16 5 46 16d 16 16d 15250 10170 67.84 45.24 10830 7220 48.18 32.12<br />

2-11/16 x 9-1/4 - 14 THDH27925 HGUS2.75/10 2-3/4 9-1/8 4 46 16d 12 16d 13525 6575 60.16 29.25 9605 4670 42.73 20.77<br />

2-11/16 x 11-1/4 - 16 THDH27112 HGUS2.75/12 2-3/4 10-7/8 4 56 16d 14 16d 16130 9845 71.75 43.79 11450 6990 50.93 31.09<br />

2-11/16 x 14 - 16 THDH2714 HGUS2.75/14 2-3/4 12-1/4 4 66 16d 16 16d 16130 11335 71.75 50.42 11450 8050 50.93 35.81<br />

3-1/4 x 9-1/2 THDH3210 HGUS3.25/10 3-3/16 9-3/8 4 46 16d 12 16d 14760 7480 65.66 33.27 10480 5310 46.62 23.62<br />

3-1/4 x 10-5/8 THDH3212 HGUS3.25/12 3-3/16 10-5/8 4 56 16d 14 16d 16130 11335 71.75 50.42 11450 8050 50.93 35.81<br />

(2) 2 x 6 - 8 THDH26-2 HGUS26-2 3-7/16 5-3/8 4 20 16d 8 16d 9035 4215 40.19 18.75 6415 2995 28.54 13.32<br />

(2) 2 x 8 - 10 THDH28-2 HGUS28-2 3-7/16 7-1/8 4 36 16d 10 16d 13075 5020 58.16 22.33 9285 3565 41.30 15.86<br />

(2) 2 x 10 - 12 THDH210-2 HGUS210-2 3-7/16 9-1/8 4 46 16d 12 16d 13525 6575 60.16 29.25 9605 4670 42.73 20.77<br />

4 x 6 - 8 THDH46 HGUS46 3-9/16 5-3/8 4 20 16d 8 16d 8290 4905 36.88 21.82 5885 3485 26.18 15.50<br />

4 x 8 - 10 THDH48 HGUS48 3-9/16 7-1/8 4 36 16d 10 16d 12825 6000 57.05 26.69 9105 4260 40.50 18.95<br />

4 x 10 - 12 THDH410 HGUS410 3-9/16 9-1/8 4 46 16d 12 16d 14760 7480 65.66 33.27 10480 5310 46.62 23.62<br />

4 x 12 - 14 THDH412 HGUS412 3-9/16 10-1/2 4 56 16d 14 16d 16130 9845 71.75 43.79 11450 6990 50.93 31.09<br />

4 x 14 - 16 THDH414 HGUS414 3-9/16 13-1/16 4 66 16d 16 16d 16130 11335 71.75 50.42 11450 8050 50.93 35.81<br />

(3) 2 x 6 - 8 THDH26-3 HGUS26-3 5-1/8 5-7/16 4 20 16d 8 16d 9035 4215 40.19 18.75 6415 2995 28.54 13.32<br />

(3) 2 x 8 - 10 THDH28-3 HGUS28-3 5-1/8 7-3/16 4 36 16d 12 16d 13075 5020 58.16 22.33 9285 3565 41.30 15.86<br />

(3) 2 x 10 - 12 THDH210-3 HGUS210-3 5-1/8 9-3/16 4 46 16d 16 16d 13190 7030 58.67 31.27 9365 4990 41.66 22.20<br />

(3) 2 x 12 - 14 THDH212-3 HGUS212-3 5-1/8 11-3/16 4 56 16d 20 16d 15465 9105 68.79 40.50 10980 6465 48.84 28.76<br />

(3) 2 x 14 - 16 THDH214-3 HGUS214-3 5-1/8 13-3/16 4 66 16d 22 16d 18810 10760 83.67 47.86 13355 7640 59.41 33.99<br />

6 x 10 - 12 THDH610<br />

HGUS5.25/10,<br />

HGUS5.50/10<br />

5-1/2 9 4 46 16d 16 16d 13190 7030 58.67 31.27 9365 4990 41.66 22.20<br />

6 x 12 - 14 THDH612<br />

HGUS5.25/12,<br />

HGUS5.50/12<br />

5-1/2 11 4 56 16d 20 16d 15465 9105 68.79 40.50 10980 6465 48.84 28.76<br />

6 x 14 - 16 THDH614 HGUS5.50/14 5-1/2 13 4 66 16d 22 16d 18810 10760 83.67 47.86 13355 7640 59.41 33.99<br />

6-3/4 x 9 - 14-1/2 THDH6710<br />

HGUS210-4,<br />

HGUS6.88/10<br />

6-7/8 8-13/16 4 46 16d 12 16d 13525 6575 60.16 29.25 9605 4670 42.73 20.77<br />

6-3/4 x 11 - 18 THDH6712<br />

HGUS212-4,<br />

HGUS6.88/12<br />

6-7/8 10-13/16 4 56 16d 14 16d 16130 9845 71.75 43.79 11450 6990 50.93 31.09<br />

6-3/4 x 13 - 20-1/2 THDH6714<br />

HGUS214-4,<br />

HGUS6.88/14<br />

6-7/8 12-13/16 4 66 16d 16 16d 16130 11335 71.75 50.42 11450 8050 50.93 35.81<br />

7 x 9-1/4 - 14 THDH7210 HGUS7.25/10 7-1/4 9 4 46 16d 12 16d 14760 7480 65.66 33.27 10480 5310 46.62 23.62<br />

7 x 11-1/4 - 16 THDH7212 HGUS7.25/12 7-1/4 10-1/2 4 56 16d 14 16d 16130 9845 71.75 43.79 11450 6990 50.93 31.09<br />

7 x 14 - 18 THDH7214 HGUS7.25/14 7-1/4 12-1/4 4 66 16d 16 16d 16130 11335 71.75 50.42 11450 8050 50.93 35.81<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

<br />

3) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

4) NAILS: <br />

red font.<br />

Header<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Options: HUS26, HUS28, & HUS210 are available in<br />

Triple Zinc. To order, add TZ to stock<br />

number, as in HUS26-TZ<br />

Codes: Load values are derived from data submitted<br />

various North American building code<br />

evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Joist nails must be driven in at a 30° to 45° angle through the<br />

joist or truss into the header to achieve listed loads. Standard<br />

length “double shear” nails must be used to achieve<br />

listed load values.<br />

Truss<br />

DF-L (Lbs)<br />

Factored Resistance<br />

DF-L (kN)<br />

Double shear nail design<br />

features fewer nails and<br />

faster installation<br />

S-P-F (Lbs)<br />

Uses standard<br />

length nails<br />

S-P-F (kN)<br />

Raised<br />

dimple allows<br />

30˚ to 45<br />

nailing<br />

Typical HUS<br />

installation<br />

W<br />

HUS<br />

1˝<br />

2˝<br />

3˝<br />

H<br />

Plated Truss<br />

Dimensions (in)<br />

Fastener Schedule 3,5<br />

Header Truss 2<br />

DF-L (Lbs)<br />

Factored Resistance 4<br />

DF-L (kN)<br />

S-P-F (Lbs)<br />

S-P-F (kN)<br />

Joist /<br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Truss Size Stock No. Ref. No. Gauge W H Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

MUS26 MUS26 18 1-9/16 5-1/16 6 10d 6 10d 3245 1625 14.44 7.23 2305 1155 10.25 5.14<br />

2 x 6 - 8<br />

HUS26,<br />

HUS26<br />

LJS26DS<br />

16 1-5/8 5-7/16 14 16d 6 16d 5480 3625 24.38 16.13 3891 2574 17.31 11.45<br />

2 x 8 - 10<br />

MUS28 MUS28 18 1-9/16 7-1/16 8 10d 8 10d 4400 2315 19.57 10.30 3125 1645 13.90 7.32<br />

HUS28 HUS28 16 1-5/8 7-3/16 22 16d 8 16d 7115 4840 31.65 21.53 5052 3436 22.47 15.29<br />

2 x 10 - 12 HUS210 HUS210 16 1-5/8 9-3/16 30 16d 10 16d 9025 6035 40.15 26.85 6408 4285 28.50 19.06<br />

1-3/4 x 5-1/2 - 7-1/4 HUS175 HU1.81/5 16 1-13/16 5-3/8 14 16d 6 16d 5480 3625 24.38 16.13 3891 2574 17.31 11.45<br />

1-3/4 x 7-1/4 - 11-1/4 HUS177 -- -- 16 1-13/16 7-1/8 22 16d 8 16d 7115 4840 31.65 21.53 5052 3436 22.47 15.29<br />

1-3/4 x 9-1/4 - 14 HUS179 HUS1.81/10 16 1-13/16 9-1/8 30 16d 10 16d 9025 6035 40.15 26.85 6408 4285 28.50 19.06<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

<br />

3) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

W<br />

2˝<br />

<br />

5) NAILS<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

MUS<br />

167<br />

<strong>USP</strong>2240-131<br />

H


Adjustable Strap <strong>Hangers</strong> – MSH series<br />

The MSH is field adjustable. The flanges can be used in top mount, face mount, or<br />

combination installations. An open back design allows installation after a member is placed in position.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Options: MSH422 is available in Triple Zinc. To order, add TZ to<br />

stock number, as in MSH422-TZ.<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

NEW<br />

SIZES<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Web stiffeners are required for I-Joist installations.<br />

Mounting condition:<br />

Face-Max – Figure 1. All header nails used should be driven into the wide face of the header.<br />

Top-Max – Figure 2. The hanger is installed in a top mount condition with at least six lower header<br />

face nail holes filled, and four top flange nails filled. The strap must wrap over the top at least 2˝.<br />

Top-Min – Figure 3. The hanger is installed in a top mount condition with at least the top two<br />

header face nail holes filled, and four top flange nail holes filled. The strap must wrap over the top at<br />

least 2˝ and the joist nails shall be installed straight into the joist for all models.<br />

Combination – Figure 4. Face-Max values apply for the entire connection. Follow fastening<br />

directions above for the applicable mounting condition for each individual flange strap.<br />

B<br />

W<br />

H<br />

D<br />

MSH<br />

21 1 /2˝<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Plated Truss<br />

3 9 /16˝<br />

MSH422<br />

H<br />

22˝<br />

Double shear nail design<br />

features fewer nails and<br />

faster installation<br />

Uses standard<br />

length nails<br />

B<br />

W<br />

MSH426<br />

D<br />

3 5 /8˝<br />

MSH422IF<br />

Figure 1<br />

Figure 2 Figure 3<br />

Figure 4<br />

Typical MSH installation<br />

Face Mount Maximum<br />

Typical MSH installation<br />

Top Mount Maximum<br />

Typical MSH422-2IF<br />

installation Top Mount<br />

Minimum<br />

Typical combination<br />

MSH installation<br />

continued on next page<br />

168<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Adjustable Strap <strong>Hangers</strong> – MSH series continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Joist<br />

Material<br />

& Width<br />

<br />

or<br />

Trusses<br />

<br />

or<br />

Trusses<br />

<br />

or<br />

Trusses<br />

<br />

or<br />

Trusses<br />

<br />

or<br />

I-Joist<br />

<br />

or<br />

I-Joist<br />

<br />

I-Joist<br />

<br />

I-Joist<br />

<br />

Floor<br />

Trusses<br />

<br />

or<br />

Trusses<br />

<br />

or<br />

Trusses<br />

<br />

Floor<br />

Trusses<br />

<br />

Floor<br />

Trusses<br />

<br />

Floor<br />

Trusses<br />

<br />

Floor<br />

Trusses<br />

<br />

Floor<br />

Trusses<br />

<br />

Floor Trusses<br />

<br />

Floor<br />

Trusses<br />

<br />

Floor<br />

Trusses<br />

<br />

I-Joist<br />

<br />

I-Joist<br />

<strong>USP</strong><br />

Stock No.<br />

Steel Gauge<br />

Mounting<br />

Top Face<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Ref. No. W H D B Condition Qty Type Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

face-max -- -- -- -- 18 10d 4 10d x 1-1/2 4770 1480 21.22 6.58 3390 1050 15.08 4.67<br />

MSH29 THA29 18 1-5/8 8-3/4 2-1/4 5<br />

MSH213 THA213 18 1-5/8 12-3/4 2-1/4<br />

MSH218 THA218 18<br />

1-5/8 16-3/4 2-1/4 5<br />

MSH222 THAI222 18 1-5/8 23 1-3/4 10-13/16<br />

MSH1713 -- -- 18 1-13/16 14-7/16 1-3/4 10-3/4<br />

MSH1722 THAI1.81/22 18<br />

22-7/8<br />

MSH2022 THAI2.06/22 18 2-1/16 22-5/8 1-3/4 10-7/16<br />

MSH2322<br />

THAI3522<br />

2-3/8 22-5/8 1-3/4 10-7/16<br />

MSH322 THAI322 18 2-9/16 22-1/2 1-3/4 10-3/8<br />

MSH218-2 THA218-2 16 3-1/8 17-3/4 1-3/4 10-1/16<br />

MSH222-2 THA222-2 16 3-1/8 22-1/4 1-3/4 10-1/16<br />

MSH418 THA418 16 3-9/16 17-1/2 1-3/4<br />

14<br />

16 3-5/8 22 1-3/4 9-13/16<br />

MSH424 -- -- 16 3-5/8 22 2<br />

3-5/8 26 1-3/4<br />

22-1/8<br />

MSH426-2 THA426-2 14 7-1/4 26-1/16 2<br />

18<br />

MSH413 THA413 16 3-9/16<br />

MSH422<br />

MSH422IF<br />

MSH426<br />

MSH426IF<br />

MSH422-2<br />

MSH422-2IF<br />

<br />

THAI422<br />

<br />

THAC422<br />

<br />

THAC426<br />

THA422-2<br />

THAC422-2<br />

MSH2622-2 -- -- 16<br />

Dimensions (in)<br />

1-3/4 10-3/4<br />

1-3/4<br />

16 3-9/16 21-1/2 1-3/4<br />

14<br />

1-13/16<br />

14 7-1/4<br />

7-5/8<br />

11<br />

9-1/4<br />

MSH2322-2 -- -- 16 4-3/4 22 1-3/4 9-1/4<br />

5-3/8 22 1-3/4 9-1/4<br />

2<br />

5<br />

7-5/8<br />

7-5/8<br />

5-3/16<br />

8<br />

Fastener Schedule 2,3<br />

Header Joist DF-L (Lbs)<br />

Factored Resistance<br />

DF-L (kN) S-P-F (Lbs)<br />

top-max 4 10d 6 10d 4 10d x 1-1/2 4940 1480 21.98 6.58 3510 1050 15.61 4.67<br />

top-min 4 10d 2 10d 4 10d x 1-1/2 3690 -- -- 16.41 -- -- 2620 -- -- 11.65 -- --<br />

face-max -- -- -- -- 20 10d 4 10d 4770 1480 21.22 6.58 3390 1050 15.08 4.67<br />

top-max 4 10d 6 10d 4 10d 4940 1480 21.98 6.58 3510 1050 15.61 4.67<br />

top-min 4 10d 2 10d 4 10d x 1-1/2 3690 -- -- 16.41 -- -- 2620 -- -- 11.65 -- --<br />

face-max -- -- -- -- 26 10d 4 10d x 1-1/2 4770 1480 21.22 6.58 3390 1050 15.08 4.67<br />

top-max 4 10d 6 10d 4 10d x 1-1/2 4940 1480 21.98 6.58 3510 1050 15.61 4.67<br />

top-min 4 10d 2 10d 4 10d x 1-1/2 3690 -- -- 16.41 -- -- 2620 -- -- 11.65 -- --<br />

face-max -- -- -- -- 22 10d 4 10d x 1-1/2 3195 1120 14.21 4.98 2270 795 10.10 3.54<br />

top-max 4 10d 6 10d 4 10d x 1-1/2 4255 1120 18.93 4.98 3020 795 13.43 3.54<br />

top-min 4 10d 2 10d 4 10d x 1-1/2 3550 -- -- 15.79 -- -- 2520 -- -- 11.21 -- --<br />

face-max -- -- -- -- 12 10d 4 10d 3195 1120 14.21 4.98 2270 795 10.10 3.54<br />

top-max 4 10d 6 10d 4 10d 4255 1120 18.93 4.98 3020 795 13.43 3.54<br />

top-min 4 10d 2 10d 4 10d x 1-1/2 3550 -- -- 15.79 -- -- 2520 -- -- 11.21 -- --<br />

face-max -- -- -- -- 22 10d 4 10d x 1-1/2 3195 1120 14.21 4.98 2270 795 10.10 3.54<br />

top-max 4 10d 6 10d 4 10d x 1-1/2 4255 1120 18.93 4.98 3020 795 13.43 3.54<br />

top-min 4 10d 2 10d 4 10d x 1-1/2 3550 -- -- 15.79 -- -- 2520 -- -- 11.21 -- --<br />

face-max -- -- -- -- 22 10d 4 10d 5510 1140 24.51 5.07 3910 810 17.39 3.60<br />

top-max 4 10d 6 10d 4 10d 5305 1140 23.60 5.07 3770 810 16.77 3.60<br />

top-min 4 10d 2 10d 4 10d 3210 -- -- 14.28 -- -- 2280 -- -- 10.14 -- --<br />

face-max -- -- -- -- 22 10d 4 10d x 1-1/2 3195 1120 14.21 4.98 2270 795 10.10 3.54<br />

top-max 4 10d 6 10d 4 10d x 1-1/2 4255 1120 18.93 4.98 3020 795 13.43 3.54<br />

top-min 4 10d 2 10d 4 10d x 1-1/2 3550 -- -- 15.79 -- -- 2520 -- -- 11.21 -- --<br />

face-max -- -- -- -- 22 10d 4 10d x 1-1/2 3195 1120 14.21 4.98 2270 795 10.10 3.54<br />

top-max 4 10d 6 10d 4 10d x 1-1/2 4255 1120 18.93 4.98 3020 795 13.43 3.54<br />

top-min 4 10d 2 10d 4 10d x 1-1/2 3550 -- -- 15.79 -- -- 2520 -- -- 11.21 -- --<br />

face-max -- -- -- -- 16 10d 4 10d 3695 1140 16.44 5.07 2625 810 11.68 3.60<br />

top-max 4 10d 6 10d 4 10d 5305 1140 23.60 5.07 3770 810 16.77 3.60<br />

top-min 4 10d 2 10d 4 10d 3210 -- -- 14.28 -- -- 2280 -- -- 10.14 -- --<br />

face-max -- -- -- -- 22 10d 4 10d 5510 1140 24.51 5.07 3910 810 17.39 3.60<br />

top-max 4 10d 6 10d 4 10d 5305 1140 23.60 5.07 3770 810 16.77 3.60<br />

top-min 4 10d 2 10d 4 10d 3210 -- -- 14.28 -- -- 2280 -- -- 10.14 -- --<br />

face-max -- -- -- -- 14 10d 6 10d 5185 2955 23.06 13.15 3680 2100 16.37 9.34<br />

top-max 4 10d 6 10d 6 10d 5120 2955 22.78 13.15 3635 2100 16.17 9.34<br />

top-min 4 10d 2 10d 6 10d 3240 -- -- 14.41 -- -- 2300 -- -- 10.23 -- --<br />

face-max -- -- -- -- 18 10d 6 10d 5185 2955 23.06 13.15 3680 2100 16.37 9.34<br />

top-max 4 10d 6 10d 6 10d 5120 2955 22.78 13.15 3635 2100 16.17 9.34<br />

top-min 4 10d 2 10d 6 10d 3240 -- -- 14.41 -- -- 2300 -- -- 10.23 -- --<br />

face-max -- -- -- -- 22 10d 4 10d 5185 2955 23.06 13.15 3680 2100 16.37 9.34<br />

top-max 4 10d 6 10d 4 10d 5120 2955 22.78 13.15 3635 2100 16.17 9.34<br />

top-min 4 10d 2 10d 4 10d 3240 -- -- 14.41 -- -- 2300 -- -- 10.23 -- --<br />

face-max -- -- -- -- 22 10d 4 10d 5510 1140 24.51 5.07 3910 810 17.39 3.60<br />

top-max 4 10d 6 10d 4 10d 5305 1140 23.60 5.07 3770 810 16.77 3.60<br />

top-min 4 10d 2 10d 4 10d 3210 -- -- 14.28 -- -- 2280 -- -- 10.14 -- --<br />

face-max -- -- -- -- 36 10d 6 10d 6490 2420 28.87 10.77 4605 1720 20.48 7.65<br />

top-max 4 10d 6 10d 6 10d 4775 2420 21.24 10.77 3390 1720 15.08 7.65<br />

top-min 4 10d 2 10d 6 10d 2410 -- -- 10.72 -- -- 1710 -- -- 7.61 -- --<br />

top-max 4 16d 8 16d 6 16d 6310 3225 28.07 14.35 4480 2290 19.93 10.19<br />

top-min 4 16d 2 16d 6 16d 4480 930 19.93 4.14 3180 660 14.15 2.94<br />

face-max -- -- -- -- 26 16d 6 16d 7875 2215 35.03 9.85 5590 1570 24.87 6.98<br />

top-max 4 16d 10 16d 6 16d 7510 2215 33.41 9.85 5330 1570 23.71 6.98<br />

top-min 4 16d 4 16d 6 16d 6185 -- -- 27.51 -- -- 4390 -- -- 19.53 -- --<br />

face-max -- -- -- -- 22 10d 4 10d 5510 1140 24.51 5.07 3910 810 17.39 3.60<br />

top-max 4 10d 6 10d 4 10d 5305 1140 23.60 5.07 3770 810 16.77 3.60<br />

top-min 4 10d 2 10d 4 10d 3210 -- -- 14.28 -- -- 2280 -- -- 10.14 -- --<br />

face-max -- -- -- -- 46 10d 4 10d 5510 1140 24.51 5.07 3910 810 17.39 3.60<br />

top-max 4 10d 6 10d 4 10d 5305 1140 23.60 5.07 3770 810 16.77 3.60<br />

top-min 4 10d 2 10d 4 10d 3210 -- -- 14.28 -- -- 2280 -- -- 10.14 -- --<br />

face-max -- -- -- -- 46 10d 4 10d 5510 1140 24.51 5.07 3910 810 17.39 3.60<br />

top-max 4 10d 6 10d 4 10d 5305 1140 23.60 5.07 3770 810 16.77 3.60<br />

top-min 4 10d 2 10d 4 10d 3210 -- -- 14.28 -- -- 2280 -- -- 10.14 -- --<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

3) NAILS:<br />

red font.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 169<br />

<strong>USP</strong>2240-131<br />

S-P-F (kN)<br />

Plated Truss


Skewed Truss Hanger – MSHL/R series<br />

The MSHL/R is an adjustable 45º skew hanger designed to<br />

permit installation on a 2 x 6 or greater bottom chord, or<br />

vertical web member.<br />

1 3 /4˝<br />

Plated Truss<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Web stiffeners are required for I-Joist installations.<br />

Right skew<br />

Joist<br />

Material<br />

& Width<br />

2x Lumber<br />

or<br />

Trusses<br />

Drive nails<br />

at angle<br />

Left skew<br />

Fastener Schedule 2,3 Factored Resistance<br />

Header Joist DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

<strong>USP</strong><br />

Steel Mounting<br />

Top Face<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Stock No. Ref. No. Gauge Condition Qty Type Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

face-max -- -- -- -- 22 10d 6 10d x 1-1/2 2550 905 11.34 4.03 2190 780 9.74 3.47<br />

MSH213L/R -- -- 18 top-max 4 10d 6 10d 6 10d x 1-1/2 2500 905 11.12 4.03 2145 780 9.54 3.47<br />

top-min 4 10d 2 10d 6 10d x 1-1/2 1785 -- -- 7.94 -- -- 1535 -- -- 6.83 -- --<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

3) NAILS<br />

1 5 /8˝<br />

MSH213L<br />

13 1 /4˝<br />

Typical MSH213R installation<br />

right skew<br />

Typical MSH213L installation<br />

left skew<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Severely Skewed <strong>Hangers</strong> – MSSH series<br />

170<br />

<strong>USP</strong>’s MSSH217 hanger accommodates a skew range of 60° to 85° (30° maximum off<br />

the girder) without the need for a more expensive custom design hanger. Face nail to<br />

webs or bend the flange strap over the chord. Available in left (L) or right (R)<br />

configurations.<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• The 3 lower holes on each strap are for top nailing when the strap is bent over the truss<br />

chord. These holes are not for face nailing.<br />

• One or both straps may be bent over the bottom chord of the girder with top or<br />

backside nailing.<br />

• Note: Select the correct (right or left) hanger so that the strap on the outside of the angle<br />

will pass the end of the truss. When facing the hanger, the strap in the rear turns in the<br />

direction of the skew. The front strap turns to pass behind the end of the carried member.<br />

• Attach the hanger at the end of the truss with a single 10d x 11⁄2˝ nail into the side flange<br />

or bottom.<br />

• Place the truss in position against the girder. Push the outside strap past the end of the<br />

truss to the girder web and face nail through the top 8 holes with 10d x 11⁄2˝ nails for a<br />

1 ply girder, or 10d common nails for multiple-ply girders.<br />

• The strap inside the angle can be formed over diagonal webs (if design allows) or bend<br />

over the girder chord. Use two nails into the top and/or back side of the girder.<br />

• If the outside strap does not contact a web, bend the strap tightly over the<br />

girder chord. Use two nails into the top and/or back side of the girder.<br />

• For uplift resistance, other means of attachment are required. If both the truss and<br />

girder have vertical webs, attach a scab to pack out the girder web nearly flush with the truss<br />

web and use a field adjustable MP framing angle across the two. A top chord connection for<br />

uplift requires a flat LSTA strap tie wrapped under the girder and over the truss chord.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

MSSH217R<br />

Right shown<br />

attached to webs<br />

8 holes for<br />

face nailing<br />

3 holes for<br />

top nailing<br />

2 x 6 or 2 x 8<br />

Pocket nail<br />

MSSH217L<br />

Left shown<br />

attached<br />

to web and<br />

top of chord<br />

17 3 /16˝<br />

1 3 /4˝ 1 5 /8˝<br />

Optional<br />

bottom nail<br />

MSSH217R<br />

right shown<br />

continued on next page


Severely Skewed <strong>Hangers</strong> – MSSH series continued<br />

Back side with<br />

straps bent over<br />

Bend over<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

MP Framing<br />

Angle pg. 69-70<br />

Additional<br />

Strapping<br />

for High Uplift<br />

Additional<br />

Strapping<br />

for High Uplift<br />

Fastener Schedule 2,3,4 Factored Resistance 1<br />

Girder Truss<br />

Hip<br />

DF-L S-P-F<br />

<strong>USP</strong><br />

Steel<br />

Carrying Member Carried Member<br />

Girder<br />

Vertical (100%) Vertical (100%)<br />

Stock No. Ref. No. Gauge Qty Type Qty Type Truss Lbs kN Lbs kN<br />

MSSH217L/R -- -- 18<br />

8 10d per strap OR 1 Ply 2115 9.41 1720 7.65<br />

1 10d x 1-1/2<br />

4 10d top of bent straps 2 Ply 2450 10.90 1720 7.65<br />

Optional Construction: Parallel to Grain Loading in Hanger Seat<br />

8 10d per strap OR 1 Ply 2115 9.41 1820 8.10<br />

1 10d x 1-1/2<br />

4 10d top of bent straps 2 Ply 2450 10.90 2160 9.61<br />

1) No uplift value with this hanger. Use other hardware or nailing higher on carried member to counteract uplift.<br />

2) One or both straps may be bent over bottom chord of girder with top or backside nailing.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) NAILS<br />

Note: The 3 lower holes on each strap are for top nailing when strap is bent. These holes are not for face nailing.<br />

Skewed Nail Plate – SNP3<br />

LSTA Strap<br />

Tie pg. 77-78<br />

Back view shown<br />

Right shown<br />

bent over bottom chord<br />

Bend over<br />

Girder<br />

Truss<br />

Top view right shown<br />

Plated Truss<br />

The SNP3 Skewed Nail Plate is designed and tested for<br />

connecting square cut corner jack trusses at skews from 45˚ to 90˚.<br />

Materials: 16 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Supporting<br />

Truss<br />

3 1 /2˝<br />

Installation:<br />

• Install specified fasteners from bend line out<br />

from each end. Not all nail holes will be filled.<br />

• Attach to the supported truss on the acute angle<br />

side so the SNP3 runs behind the end of the<br />

jack.<br />

• Set jack truss against supporting truss and nail on exposed flange.<br />

• Bend angle only once.<br />

• 8d common nails may be substituted for 8d x 11/2˝ nails with no<br />

reduction in load.<br />

3 1 /2˝ Supported<br />

Truss<br />

45º to<br />

90º<br />

Typical SNP3<br />

installation<br />

<strong>USP</strong><br />

Stock No.<br />

Steel<br />

Fastener Schedule 2<br />

Factored Resistance<br />

Each End DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Vertical Upift 1 Vertical Upift 1 Vertical Upift 1 Vertical Upift 1<br />

Ref. No. Gauge Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

SNP3 TJC37 16 6 8d x 1-1/2 765 660 3.40 2.94 720 660 3.20 2.94<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase is allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

3) NAILS<br />

3 3 /8˝<br />

3 1 /2˝<br />

3 1 /2˝<br />

SNP3<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 171<br />

<strong>USP</strong>2240-131


Breakfast Nook <strong>Hangers</strong> – BN series<br />

Designed to carry four mono trusses in one connector, it reduces installation time and<br />

cost. Provides a tested, load rated connection. Standard configuration spacing:<br />

22 1 /2°, 45°, 45°, 45°, 22 1 /2°. The design also includes field adjustable nailing tabs.<br />

Plated Truss<br />

Materials: 14 gauge<br />

Finish: <strong>USP</strong> primer<br />

Codes: Load values are derived from data submitted to various North<br />

American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Allow a 2˝ setback for each mono truss.<br />

• For pitched ceiling, design mono trusses with end-vertical upset.<br />

Upset equals tangent of the ceiling slope times 5.6˝.<br />

• Bend tab only once.<br />

22 1/2º 1 22 1/2º 1 45º<br />

45º<br />

45º<br />

BN264<br />

Standard configuration<br />

(top view)<br />

Nailing tabs<br />

adjust to fasten<br />

22 1 /2º mono trusses<br />

Field adjustable<br />

nailing tabs<br />

with slotted<br />

fastening holes<br />

for slant nailing<br />

B<br />

Typical BN264<br />

installation<br />

BN264<br />

L<br />

H<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Dimensions (in)<br />

Fastener Schedule 3,5<br />

Factored Resistance 2<br />

Carrying Carried Member<br />

DF-L<br />

S-P-F<br />

<strong>USP</strong><br />

Steel<br />

Member per Mono Truss Vertical (100%) Uplift (115%) 1,4 Vertical (100%) Uplift (115%) 1,4<br />

Stock No. Ref. No. Gauge L H B Qty Type Qty Type Lbs. kN Lbs. kN Lbs. kN Lbs. kN<br />

BN264 THJM2-4-SDS3 14 10 5-3/8 3-1/4 20 10d 2 10d x 1-1/2 4565 20.31 1220 5.43 3240 14.41 865 3.85<br />

BN284 -- -- 14 10 7-1/8 3-1/4 20 10d 2 10d x 1-1/2 4565 20.31 1220 5.43 3240 14.41 865 3.85<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Loading published for total load of connection.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) Maximum uplift per mono truss is 180 lbs. at 115% for DF-L and 155 lbs. at 115% for S-P-F.<br />

5) NAILS<br />

172<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Hip/Jack <strong>Connectors</strong> – HHC, HJC, HJHC, & HTHJ series<br />

HHC – Designed to support 1 ply hip and jack truss/rafters. Contact <strong>USP</strong> when<br />

using multi-ply applications.<br />

HJHC – Allows for hip/hip support and hip/ jack/hip installations.<br />

HJC & HTHJ – Used to simultaneously hang a combination of hips and jacks off<br />

girder trusses. These hangers fit both left-hand and right-hand applications.<br />

An open back design allows for retrofit installations.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: HHC, HJC, & HJHC – 12 gauge;<br />

HTHJ –18 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to various North<br />

American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

45º 45º<br />

Typical HJC/HTHJ<br />

installation top view<br />

45º 45º 45º 45º<br />

Typical HHC<br />

installation top view<br />

Typical HJC/HTHJ<br />

installation<br />

Typical HJHC<br />

installation top view<br />

Plated Truss<br />

H<br />

H<br />

H<br />

H<br />

6˝<br />

3 1 /4˝<br />

9˝<br />

3 1 /4˝<br />

10 1 /2˝<br />

3 1 /4˝<br />

5 7 /8˝<br />

5˝<br />

HJC<br />

HHC<br />

HJHC<br />

HTHJ<br />

Carrying Member<br />

Fastener Schedule 3,4<br />

Carried Member<br />

DF-L (Lbs)<br />

Factored Resistance 2<br />

DF-L (kN)<br />

<strong>USP</strong><br />

Steel H<br />

per Hip per Jack Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Description Stock No. Ref. No. Gauge (in) Qty Type Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

LTHJA26,<br />

2 x 6 right / left HJC26 THJA26, 12 5-3/8 16 16d 5 10d 7 10d 5740 3070 25.53 13.66 4075 2180 18.13 9.70<br />

THJU26<br />

2 x 8 right / left HJC28 -- -- 12 7-1/8 20 16d 6 10d 8 10d 5740 3070 25.53 13.66 4075 2180 18.13 9.70<br />

2 x 6 terminal HHC26<br />

LTHJA26,<br />

THJA26<br />

12 5-7/16 20 16d 5 10d -- -- -- -- 4235 2075 18.84 9.23 3660 1810 16.28 8.05<br />

2 x 8 terminal HHC28 -- -- 12 7-3/16 24 16d 6 10d -- -- -- -- 5085 2490 22.62 11.08 4390 2175 19.53 9.68<br />

2 x 6 terminal HJHC26 -- -- 12 5-7/16 20 16d 5 10d 2 10d 4235 2075 18.84 9.23 3660 1810 16.28 8.05<br />

2 x 8 terminal HJHC28 -- -- 12 7-3/16 24 16d 6 10d 2 10d 5085 2490 22.62 11.08 4390 2175 19.53 9.68<br />

2 x 6 terminal HTHJ26-18 -- -- 18 5 16 16d 7 16d 5 16d 4375 1125 19.46 5.00 3105 800 13.81 3.56<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Loading published for total load of hip / jack connection.<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) NAILS<br />

S-P-F<br />

S-P-F (kN)<br />

HJC Specialty Options Chart<br />

Option<br />

Range<br />

Factored<br />

Resistance<br />

Ordering<br />

Hip Truss Skew<br />

<br />

<br />

<br />

<br />

<br />

Varies<br />

8˝ max. width<br />

HJC (skewed)<br />

3 1 /4˝<br />

H<br />

Specify angle<br />

(60° max)<br />

Typical HJC (skewed) installation<br />

with alternate skew angle top view<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 173<br />

<strong>USP</strong>2240-131


Girder Truss <strong>Hangers</strong> – GT, GTD & GTS series<br />

The GT primarily hangs girder trusses off other girder trusses, although a wide variety<br />

of other heavy-duty installations apply.<br />

Materials: See chart<br />

Finish: <strong>USP</strong> primer<br />

Options: All models available in LVL sizes, use M in place of T, as in GT2M4B.<br />

Codes: Load values are derived from data submitted to various North<br />

American building code evaluators.<br />

Plated Truss<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Minimum heel height is 91/4˝ for GT hangers.<br />

Supported<br />

Member<br />

2 ply<br />

3 ply<br />

4 ply<br />

5 ply<br />

<strong>USP</strong><br />

Stock No.<br />

GT2T2B<br />

GT2T2BH<br />

GT2T3B<br />

GT2T4B<br />

GT2T6B<br />

GT2T6BH<br />

GT2T8B<br />

GT3T3B<br />

GT3T3BH<br />

GT3T4B<br />

GT3T4BH<br />

GT3T6B<br />

GT3T6BH<br />

GT3T8B<br />

GT3T8BH<br />

GT4T4B<br />

GT4T4BH<br />

GT4T6B<br />

GT4T6BH<br />

GT4T8B<br />

GT5T8BH<br />

Steel Gauge Dimensions (in)<br />

Fastener Schedule 2,3,4 Factored Resistance<br />

Supporting Supported<br />

Supporting Member<br />

Truss<br />

Truss<br />

1 Ply<br />

2 Ply<br />

3 Ply Uplift<br />

Wood<br />

(100%)<br />

(100%)<br />

Back<br />

Bolt<br />

(100%)<br />

(115%) 1<br />

Species<br />

Ref. No. Plate Strap W1 L H D B Qty Dia. 2 Qty Type Lbs kN Lbs kN Lbs kN Lbs kN<br />

DF-L 2440 10.85 4235 18.84 4775 21.24 2485 11.05<br />

-- -- 3 7 6 19 2 12 16d<br />

S-P-F 2140 9.52 3600 16.01 4405 19.60 2485 11.05<br />

DF-L 3210 14.28 5625 25.02 8195 36.45 2485 11.05<br />

-- -- 3 7 6 2 1 12 16d<br />

S-P-F 2800 12.46 4775 21.24 6975 31.03 2485 11.05<br />

DF-L 3540 15.75 6270 27.89 7130 31.72 2485 11.05<br />

-- -- 3 7 6 22 3 12 16d<br />

S-P-F 3075 13.68 5305 23.60 6560 29.18 2485 11.05<br />

DF-L 4905 21.82 8475 37.70 9555 42.50 2485 11.05<br />

THGB2 3 7 7 19 4 12 16d<br />

S-P-F 4290 19.08 7215 32.10 8825 39.26 2485 11.05<br />

DF-L 7375 32.81 12720 56.58 14330 63.75 2485 11.05<br />

-- -- 3 7 22 6 6 12 16d<br />

S-P-F 6465 28.76 10835 48.20 13240 58.90 2485 11.05<br />

DF-L 9770 43.46 16935 75.33 19320 85.94 2485 11.05<br />

-- -- 3 7 6 6 1 12 16d<br />

S-P-F 8545 38.01 13730 61.08 13730 61.08 2485 11.05<br />

DF-L 9800 43.59 16950 75.40 19100 84.96 2485 11.05<br />

THGBH2 3 7 25 6 8 12 16d<br />

S-P-F 8580 38.17 13730 61.08 13730 61.08 2485 11.05<br />

DF-L 3540 15.75 6270 27.89 7130 31.72 2485 11.05<br />

-- -- 3 7 6 22 3 12 16d<br />

S-P-F 3075 13.68 5305 23.60 6560 29.18 2485 11.05<br />

DF-L 4530 20.15 8230 36.61 12175 54.16 2485 11.05<br />

-- -- 3 7 6 3 1 12 16d<br />

S-P-F 3880 17.26 6920 30.78 10295 45.80 2485 11.05<br />

DF-L 4905 21.82 8475 37.70 9555 42.50 2485 11.05<br />

THGB3 3 7 7 19 4 12 16d<br />

S-P-F 4290 19.08 7215 32.10 8825 39.26 2485 11.05<br />

DF-L 6475 28.80 11275 50.16 16395 72.93 2485 11.05<br />

-- -- 3 7 7 4 1 12 16d<br />

S-P-F 5650 25.13 9575 42.59 13975 62.17 2485 11.05<br />

DF-L 7375 32.81 12720 56.58 14330 63.75 2485 11.05<br />

-- -- 3 7 22 6 6 12 16d<br />

S-P-F 6465 28.76 10835 48.20 13240 58.90 2485 11.05<br />

DF-L 9770 43.46 16935 75.33 24595 109.41 2485 11.05<br />

-- -- 3 7 6 6 1 12 16d<br />

S-P-F 8545 38.01 14405 64.08 19240 85.59 2485 11.05<br />

DF-L 9800 43.59 16950 75.40 19100 84.96 2485 11.05<br />

THGBH3 3 7 25 6 8 12 16d<br />

S-P-F 8580 38.17 14430 64.19 17655 78.54 2485 11.05<br />

DF-L 12925 57.50 22520 100.18 27585 122.71 2485 11.05<br />

-- -- 3 7 6 8 1 12 16d<br />

S-P-F 11030 49.07 18905 84.10 19375 86.19 2485 11.05<br />

DF-L 4895 21.77 8475 37.70 9555 42.50 2485 11.05<br />

-- -- 3 7 19 4 12 16d<br />

S-P-F 4290 19.08 7215 32.10 8825 39.26 2485 11.05<br />

DF-L 6465 28.76 11270 50.13 16400 72.95 2485 11.05<br />

-- -- 3 7 4 1 12 16d<br />

S-P-F 5645 25.11 9575 42.59 13975 62.17 2485 11.05<br />

DF-L 7375 32.81 12715 56.56 14330 63.75 2485 11.05<br />

-- -- 3 7 22 6 6 12 16d<br />

S-P-F 6465 28.76 10835 48.20 13240 58.90 2485 11.05<br />

DF-L 9765 43.44 16925 75.29 24600 109.43 2485 11.05<br />

-- -- 3 7 6 6 1 12 16d<br />

S-P-F 8545 38.01 14405 64.08 20975 93.31 2485 11.05<br />

DF-L 9800 43.59 16940 75.36 19110 85.01 2485 11.05<br />

THGBH4 3 7 25 6 8 12 16d<br />

S-P-F 8580 38.17 14430 64.19 17645 78.49 2485 11.05<br />

DF-L 12910 57.43 22495 100.07 32745 145.66 2485 11.05<br />

-- -- 3 7 6 8 1 12 16d<br />

S-P-F 11275 50.16 19115 85.03 27895 124.09 2485 11.05<br />

1) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Bolts shall conform to ASTM A 307 Grade A or better.<br />

3) GT series require 2 x 6 vertical member for 2, 3, and 4 bolt hangers and 2 x 8 for 6 and 8 bolt hangers.<br />

4) NAILS<br />

Typical GT2T4B<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

continued on next page<br />

174<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Girder Truss <strong>Hangers</strong> – GT, GTD & GTS series cont.<br />

L<br />

H<br />

45º<br />

W 2<br />

W2<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

W 2<br />

B<br />

45º 45º<br />

D<br />

W 1 W 1<br />

W W 1<br />

1<br />

GT<br />

Supported<br />

Member<br />

<strong>USP</strong><br />

Stock No.<br />

*GT2T2BSKL/R<br />

2 ply<br />

skewed 45°<br />

*GT2T4BSKL/R<br />

1 ply<br />

hip & jack<br />

2 ply hip<br />

& 1 ply jack<br />

1 ply<br />

terminal hip<br />

2 ply<br />

terminal hip<br />

*GTS1T1H3BSKL/R<br />

*GTS1T1H4BSKL/R<br />

*GTS1T2H3BSKL/R<br />

GTD1T1H3B<br />

GTD1T2H3B<br />

GT2T4B<br />

GT series – Hip Applications<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

-- --<br />

Steel<br />

Gauge<br />

3<br />

3<br />

3<br />

3<br />

3<br />

3<br />

7<br />

7<br />

7<br />

7<br />

7<br />

7<br />

3-7/16<br />

1-5/8<br />

1-5/8<br />

1-5/8<br />

1-5/8<br />

1-5/8<br />

Dimensions (in)<br />

22 **4-1/2 5-1/2<br />

22 **4-1/2 5-1/2<br />

Supporting<br />

Truss<br />

1) The listed loads for GTS and GTD is the total of hip and jack connection.<br />

2) Factored uplift resistance has been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

3) Bolts shall conform to ASTM A 307 or better.<br />

4) NAILS<br />

<br />

<br />

<br />

**D is 3" for hip bucket.<br />

-- --<br />

1-5/8<br />

7-1/4<br />

9-1/4<br />

19<br />

4-1/2 9-1/4<br />

22 **4-1/2 5-1/2<br />

1-5/8 9-1/4 19 **4-1/2 5-1/2<br />

3-7/16 9-1/4 22 **4-1/2 5-1/2<br />

1-5/8<br />

6<br />

3-7/16 8<br />

GTS<br />

left shown<br />

5<br />

4<br />

5<br />

4<br />

3<br />

3<br />

GTS1T2H3BSKL<br />

left shown<br />

3/4 12<br />

Fastener Schedule 4<br />

Supported<br />

Truss<br />

4 10d x 1-1/2 4<br />

4<br />

16d<br />

10d x 1-1/2<br />

-- --<br />

4 10d x 1-1/2 4<br />

10d x 1-1/2<br />

4<br />

Supported<br />

Hip<br />

-- --<br />

10d x 1-1/2<br />

Factored Resistance 1<br />

Supporting Member<br />

1 Ply<br />

2 Ply<br />

3 Ply Uplift<br />

(100%) (100%) (100%) (115%) 2<br />

Back<br />

Bolt<br />

Wood<br />

Ref. No. Plate Strap W1 W2 L H D B Qty Dia. 3 Qty Type Qty Type Species Lbs kN Lbs kN Lbs kN Lbs kN<br />

-- -- 3 7 3-7/16 -- -- 6 19 4-1/2 9-1/4 3 3/4 12 16d -- -- -- --<br />

DF-L 2440 10.85 4225 18.79 4765 21.20 2485 11.05<br />

S-P-F 2130 9.48 3595 15.99 4400 19.57 2485 11.05<br />

3/4<br />

3/4<br />

3/4<br />

3/4<br />

4<br />

3/4 4 10d x 1-1/2 4<br />

The GTWS series girder-to-girder hangers feature high uplift capacities<br />

along with high gravity load ratings.<br />

4<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

10d x 1-1/2<br />

High Uplift Girder Truss <strong>Hangers</strong> – GTWS series<br />

GTD<br />

GTD1T1H3B<br />

DF-L 4875 21.69 8455 37.61 9540 42.44 2485 11.05<br />

S-P-F 4270 18.99 7195 32.01 8805 39.17 2485 11.05<br />

DF-L 3520 15.66 6235 27.74 7085 31.52 -- -- -- --<br />

S-P-F 3055 13.59 5280 23.49 6525 29.03 -- -- -- --<br />

DF-L 4875 21.69 8445 37.57 9535 42.42 -- -- -- --<br />

S-P-F 4260 18.95 7185 31.96 8300 36.92 -- -- -- --<br />

DF-L 3520 15.66 6235 27.74 7085 31.52 -- -- -- --<br />

S-P-F 3055 13.59 5280 23.49 6525 29.03 -- -- -- --<br />

DF-L 3540 15.75 6270 27.89 7130 31.72 -- -- -- --<br />

S-P-F 3075 13.68 5305 23.60 6560 29.18 -- -- -- --<br />

DF-L 3530 15.70 6240 27.76 7100 31.58 -- -- -- --<br />

S-P-F 3060 13.61 5285 23.51 6530 29.05 -- -- -- --<br />

Plated Truss<br />

Materials: 10 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• WS Wood Screws are included with hangers where specified.<br />

• GTWS2T shall be installed to a minimum 2x4 vertical member of a<br />

girder truss with no restriction on the size of the bottom chord.<br />

• GTWS3T shall be installed to a minimum 2x6 vertical member of a<br />

girder truss with no restriction on the size of the bottom chord.<br />

• GTWS4T shall be installed to a minimum 2x8 vertical member of a<br />

girder truss with no restriction on the size of the bottom chord.<br />

16˝<br />

5˝<br />

W<br />

GTWS3T<br />

Typical GTWS<br />

installation<br />

Dimensions (in) Fastener Schedule<br />

Factored Resistance 1,3<br />

Supporting Supported DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

<strong>USP</strong><br />

Steel<br />

Truss Truss Vertical Uplift 1 Vertical Uplift Vertical Uplift 1 Vertical Uplift 1<br />

Stock No. Ref. No. Gauge W H D Qty Type 2,3 Qty Type 2,3 100% 115% 100% 115% 100% 115% 100% 115%<br />

GTWS2T -- -- 10 3-1/4 16 4 22 WS3 16 WS3 20425 17515 90.86 77.91 14500 12435 64.50 55.32<br />

GTWS3T -- -- 10 4-7/8 16 5 28 WS3 24 WS3 20425 23530 90.86 104.67 14500 16705 64.50 74.31<br />

GTWS4T -- -- 10 6-1/2 16 5 28 WS3 24 WS3 20425 23530 90.86 104.67 14500 16705 64.50 74.31<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

<br />

<br />

16˝<br />

4˝<br />

W<br />

GTWS2T<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 175<br />

<strong>USP</strong>2240-131


Girder Truss <strong>Hangers</strong> – GTQ & GTQM series<br />

The GTQ & GTQM hangers connect to multi-ply girder truss with <strong>USP</strong>’s WS Wood Screws<br />

offering high load capacities. Design features minimum and maximum fastening<br />

installation options to accommodate various sizes of vertical web. GTQM’s are designed for<br />

LVL sizes, for example GTQM218.<br />

Plated Truss<br />

<strong>USP</strong><br />

Stock No.<br />

GTQ218<br />

GTQM218 7<br />

GTQ318<br />

GTQM318 7<br />

GTQ420<br />

Materials:<br />

Finish:<br />

Supporting Truss 5<br />

Dimensions (in)<br />

Fastener Schedule<br />

Factored Resistance<br />

Min.<br />

Vert.<br />

Supported Member 8<br />

DF-L<br />

S-P-F<br />

Install Web<br />

Min. #<br />

No. of<br />

Vertical Uplift 1 Vertical Uplift 1<br />

Ref. No. W H D Type Size Qty Type 2,3,4 of Plies Qty 6 Type 2,3 Plies Unit 100% 115% 100% 115%<br />

<strong>USP</strong> WS<br />

Lbs 11735 7854 10059 6732<br />

18<br />

2 20 WS3<br />

<br />

<br />

kN 52.20 34.94 44.74 29.95<br />

3-1/4 18 4-1/2<br />

2<br />

<br />

<strong>USP</strong> WS<br />

Lbs 19553 7854 16760 6732<br />

30<br />

2 20 WS3<br />

<br />

kN 86.98 34.94 74.56 29.95<br />

<strong>USP</strong> WS<br />

Lbs 11735 7373 10059 7373<br />

18<br />

2 20 WS3<br />

<br />

kN 52.20 32.80 44.74 32.80<br />

-- -- 3-5/8 18 4-1/2<br />

2<br />

30<br />

<strong>USP</strong> WS<br />

Lbs 19553 7373 16760 7373<br />

2 20 WS3<br />

<br />

kN 86.98 32.80 74.56 32.80<br />

<strong>USP</strong> WS<br />

Lbs 16334 7854 14001 6732<br />

25<br />

2 20 WS45<br />

<br />

<br />

kN 72.66 34.94 62.28 29.95<br />

4-7/8 18 5<br />

3<br />

<br />

<strong>USP</strong> WS<br />

Lbs 20823 7854 17848 6732<br />

33<br />

2 20 WS45<br />

<br />

kN 92.63 34.94 79.40 29.95<br />

<strong>USP</strong> WS<br />

Lbs 16334 7373 14001 7373<br />

25<br />

2 20 WS45<br />

<br />

kN 72.66 32.80 62.28 32.80<br />

-- -- 5-1/2 18 5 3<br />

33<br />

<strong>USP</strong> WS<br />

Lbs 20823 7373 17848 7373<br />

2 20 WS45<br />

<br />

kN 92.63 32.80 79.40 32.80<br />

<strong>USP</strong> WS<br />

Lbs 20542 7854 17607 6732<br />

41<br />

3 20 WS6<br />

<br />

kN 91.38 34.94 78.32 29.95<br />

5-3/4<br />

4<br />

47<br />

<strong>USP</strong> WS<br />

Lbs 23974 7854 20549 6732<br />

3 20 WS6<br />

<br />

kN 106.65 34.94 91.41 29.95<br />

-- -- 7-1/4 20 5-3/4<br />

GTQM420 7 6-1/2 20<br />

7 gauge<br />

G90 galvanizing<br />

Installation:<br />

• Use all WS wood screws as specified.<br />

• Install hanger centered on vertical web.<br />

• GTQ’s are designed to be installed on various sizes of vertical web. Maintain a minimum<br />

5/8” fastener edge distance where truss connector plates are not present.<br />

• Install WS wood screws in all fastener holes including diamond holes for maximum values.<br />

Typical GTQ318<br />

installation<br />

(GTQM318 similar)<br />

6 ¼"<br />

41<br />

47<br />

18"<br />

5"<br />

W<br />

GTQ318<br />

(GTQM318 similar)<br />

<strong>USP</strong> WS<br />

<br />

<strong>USP</strong> WS<br />

<br />

Typical GTQ420<br />

installation<br />

(GTQM420 similar)<br />

Lbs 20542 7373 17607 7373<br />

kN 91.38 32.80 78.32 32.80<br />

Lbs 23974 7373 20549 7373<br />

kN 106.65 32.80 91.41 32.80<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

<br />

red font.<br />

3<br />

3<br />

20 WS6<br />

20 WS6<br />

4<br />

5 15/16"<br />

NEW<br />

20"<br />

5 ¾"<br />

W<br />

GTQ420<br />

(GTQM420 similar)<br />

Typical GTQ218<br />

installation<br />

(GTQM218 similar)<br />

6 ¼"<br />

H<br />

D<br />

W<br />

GTQ218<br />

(GTQM218 similar)<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

176<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Scissor Truss Clips – STC series<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

The STC provides uplift resistance by securing trusses to top plates.<br />

Slotted nail holes allow for horizontal movement as scissor trusses<br />

deflect.<br />

Materials: 12 gauge<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Fastener Schedule 2,3 Dimensions (in)<br />

Factored Resistance (115%) 1<br />

<strong>USP</strong><br />

Steel<br />

Truss<br />

Plate DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Stock No. Ref. No. Gauge Description W1 W2 Qty Type Qty Type F1 Uplift F1 Uplift F1 Uplift F1 Uplift<br />

STC24 TC24 12 2 x 4 top plate 3-9/16 1-5/8 5 10d x 1-1/2 6 10d x 1-1/2 550 1525 2.45 6.78 390 1085 1.73 4.83<br />

STC26 TC26 12 2 x 6 top plate 5-1/2 1-5/8 5 10d x 1-1/2 6 10d x 1-1/2 550 1525 2.45 6.78 390 1085 1.73 4.83<br />

STC28 TC28 12 2 x 8 top plate 7-1/4 1-5/8 5 10d x 1-1/2 6 10d x 1-1/2 550 1525 2.45 6.78 390 1085 1.73 4.83<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS: <br />

FLOOR TRUSS CLIPS – FTC SERIES<br />

The FTC slides easily onto the top or bottom chord and provides a guide to<br />

help position and support the second truss during assembly.<br />

Materials:<br />

Finish:<br />

Codes:<br />

18 gauge<br />

G90 galvanizing<br />

Factored resistances are derived from data submitted<br />

to various North American building code evaluators<br />

and are in accordance with CSA O86-09.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• The truss designer must determine the number of clips required<br />

and the spacing between clips based on loading conditions.<br />

Concentrated Load condition (side-loaded onto a 2-ply truss):<br />

• The FTC clips shall be installed in pairs, or multiples of two, on<br />

either side of, and within 12" of a concentrated load.<br />

4 3 /8˝<br />

• Divide half of the concentrated load by the clip capacity to<br />

determine the number of clips required.<br />

Example:<br />

Concentrated load = 3000 lbs. FTC1 capacity (DF-L) = 1245 lbs<br />

1<br />

⁄2 (3000 lbs)<br />

= 1.2 = 2 clips<br />

1245 lbs<br />

Install two FTC1 clips, one on each side of, and within 12" of the<br />

concentrated load.<br />

Uniform Load condition (side-loaded onto a 2-ply truss):<br />

• To transfer uniform loads to the second ply, the FTC clips shall be<br />

installed at a regular interval along the loaded chord. Spacing<br />

between clips is limited to 24" maximum.<br />

• Divide the clip capacity by half of the required load per lineal foot<br />

(PLF) to determine the spacing between clips.<br />

Example:<br />

Uniformly distributed load = 500 PLF. FTC1 capacity (DF-L) = 1245 lbs<br />

1245 lbs<br />

1<br />

= 4.98' spacing<br />

⁄2 (500 PLF)<br />

Space clips at 24" (MAX) along the loaded chord.<br />

4 3 /8˝<br />

W 1<br />

H<br />

2˝ 1 1 /8˝<br />

FTC<br />

6 1 /16˝<br />

W 2<br />

3 1 /16˝<br />

2 1 /16˝<br />

F 1<br />

Typical STC<br />

installation<br />

Installation:<br />

• Use all specified fasteners.<br />

See Product Notes, page 10.<br />

• When installing, do not fully set<br />

nails.<br />

• Locate nails into the center of<br />

slots to allow for horizontal<br />

movement.<br />

Step 1 Step 2<br />

Typical FTC2F retrofit installation<br />

Dimensions (in) Fastener Schedule 2,4 Factored Maximum Transfer Resistance 1,3<br />

Truss <strong>USP</strong><br />

Steel<br />

DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

7 5/8˝<br />

Size Stock No. Ref. No. Gauge W1 W2 H Qty Type 100% 100% 100% 100%<br />

4<br />

3 x 2 FTC32 -- -- 18 2-1/2 2-1/16 1-1/2 10 10d x 1-1/2 980 4.36 850 3.78<br />

3/8˝<br />

FTC1 -- -- 18 3-1/2 3-1/16 1-1/2 10 10d x 1-1/2 1245 5.54 1080 4.80<br />

4 x 2<br />

2 1/16˝<br />

FTC1F -- -- 18 3-1/16 -- -- 4-3/8 10 10d x 1-1/2 1245 5.54 1080 4.80<br />

FTC2 -- -- 18 3-1/2 3-1/16 3 10 10d 1245 5.54 1080 4.80<br />

(2) 4 x 2<br />

FTC2F -- -- 18 3-1/16 -- -- 4-3/8 10 10d 1245 5.54 1080 4.80<br />

3 1/16˝<br />

1) Factored transfer resistances are for 100% floor load, and shall not be increased for short term load duration.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

FTC2F<br />

3) Truss designer shall determine the number of clips for concentrated loads and the spacing for uniform loads.<br />

4) NAILS:<br />

New products or updated product information are designated in red font.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 177<br />

<strong>USP</strong>2240-131<br />

W 2<br />

W 1<br />

1 1/4˝ slots<br />

STC<br />

FTC1F<br />

Typical FTC<br />

installation<br />

Typical FTC<br />

2 ply metal web<br />

truss installation<br />

Plated Truss


Supplementary Bearing Plates – SBP series<br />

Plated Truss<br />

Use the SBP instead of extra truss plies or nail-on scabs to<br />

distribute concentrated truss reactions and avoid top plate crushing.<br />

The two-piece design accommodates any number of girder plies. A<br />

wraparound design gives superior uplift resistance, and reinforcement<br />

ribs effectively distribute bearing loads. Works with both single and<br />

double 2x4 or 2x6 top plates.<br />

Materials: 16 gauge<br />

Finish: G90 galvanizing<br />

Codes: Factored resistances are derived from data submitted<br />

to various North American building code evaluators<br />

and are in accordance with CSA O86-09.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• The SBP shall be installed in pairs.<br />

Factored Resistance (Lbs) Factored Resistance (kN)<br />

No. of<br />

Wood F c SBP's Alone SBP + Truss Bearing SBP's Alone SBP + Truss Bearing<br />

Truss<br />

Species (psi) Plies 100% 100% EBL 100% 100% EBL<br />

SBP4 on 2x4 / 2x6 Top Plate and Alternate Installation<br />

1 5035 9300 7.63 22.40 41.37 193.88<br />

DF-L 1015<br />

2 5035 13565 5.57 22.40 60.33 141.39<br />

3 5035 17825 4.88 22.40 79.30 123.89<br />

4 5035 22090 4.53 22.40 98.27 115.14<br />

1 3575 6805 7.38 15.90 30.26 187.34<br />

S-P-F 769<br />

2 3575 10030 5.44 15.90 44.63 138.12<br />

3 3575 13260 4.79 15.90 58.99 121.71<br />

4 3575 16490 4.47 15.90 73.35 113.51<br />

1 3930 6730 8.41 17.48 29.95 213.59<br />

Hem Fir 667<br />

2 3930 9535 5.95 17.48 42.41 151.24<br />

3 3930 12335 5.14 17.48 54.88 130.46<br />

4 3930 15140 4.73 17.48 67.34 120.07<br />

SBP6 on 2x6 / 2x8 Top Plate and Alternate Installation<br />

1 7315 14015 11.50 32.54 62.35 292.21<br />

DF-L 1015<br />

2 7315 20715 8.50 32.54 92.15 215.96<br />

3 7315 27415 7.50 32.54 121.96 190.54<br />

4 7315 34115 7.00 32.54 151.77 177.83<br />

1 5195 10270 11.13 23.11 45.68 282.75<br />

S-P-F 769<br />

2 5195 15340 8.31 23.11 68.24 211.23<br />

3 5195 20415 7.38 23.11 90.81 187.38<br />

4 5195 25490 6.91 23.11 113.38 175.46<br />

1 5705 10110 12.63 25.38 44.97 320.70<br />

Hem Fir 667<br />

2 5705 14510 9.06 25.38 64.55 230.20<br />

3 5705 18915 7.88 25.38 84.14 200.03<br />

4 5705 23320 7.28 25.38 103.73 184.95<br />

1) Factored resistance is for a pair of SBP devices.<br />

2) Multiple ply trusses shall be fastened together to act as a single unit.<br />

3) EBL denotes effective bearing length and includes the actual bearing length plus the contribution<br />

of the SBP device.<br />

4) Assumes full seating of truss on top plate.<br />

Dimensions<br />

(in)<br />

Fastener Schedule 2,6<br />

Plate<br />

Truss<br />

DF-L (Lbs)<br />

<strong>USP</strong><br />

Truss/Joist<br />

Top 5 Sides<br />

Stock No. Ref. No. W H Thickness Qty Type Qty Type Qty Type Application F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift F1 F2 Uplift<br />

20 10dx1-1/2 <br />

10d 8 10d 2880 2435 1730 <br />

20 10d <br />

20 10dx1-1/2 One Tab Up<br />

3-1/2 <br />

10d 8 10d<br />

2880 2230 <br />

20 10d (2x6 Top Plate)<br />

20 10dx1-1/2 One Tab Up<br />

10d 8 10d<br />

1880 1315 1435 8.36 5.85 6.38 1120 1125 805 4.98 5.00 3.58<br />

20 10d (Alternate)<br />

28 10dx1-1/2 <br />

10d 8 10d<br />

2880 2435 1730 <br />

28 10d <br />

28 10dx1-1/2 One Tab Up<br />

<br />

10d 8 10d<br />

2880 2230 <br />

28 10d (2x8 Top Plate)<br />

28 10dx1-1/2 One Tab Up<br />

10d 8 10d<br />

1880 1315 1435 8.36 5.85 6.38 1120 1125 805 4.98 5.00 3.58<br />

28 10d (Alternate)<br />

W<br />

SBP<br />

Factored Resistance (115%) 1,3<br />

DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

<br />

<br />

<br />

<br />

<br />

NAILS: <br />

red font.<br />

H<br />

W<br />

L<br />

H<br />

D<br />

SBP one tab up<br />

D<br />

L<br />

F 1<br />

F 2<br />

Typical SBP<br />

standard installation<br />

Typical SBP6<br />

one tab up on a 2x8 top<br />

plate installation<br />

(SBP4 similar)<br />

Typical SBP one tab up<br />

alternate installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

178<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Roof Truss Ties – TR series<br />

Slotted design allows truss to deflect without imposing load on wall below.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Fastener Schedule 6,7 S-P-F<br />

Factored Resistance (115%) 1<br />

Truss Plate DF-L<br />

<strong>USP</strong><br />

Steel<br />

Without Gap 2 3 4 Without Gap 2 3 4<br />

Stock No. Ref. No. Gauge Description Qty Type Qty Type Unit F1 5 F2 F1 5 F2 F1 5 F2 F1 5 F2 F1 5 F2 F1 5 F2<br />

TR1<br />

<br />

Lbs 105 60 45 45 -- -- -- -- 90 50 35 35 -- -- -- --<br />

18 single slot 1 8d 2 8d<br />

<br />

kN 0.47 0.27 0.20 0.20 -- -- -- -- 0.40 0.22 0.16 0.16 -- -- -- --<br />

TR1T<br />

TR2<br />

<br />

DTC<br />

16<br />

18<br />

single slot<br />

double slot<br />

1<br />

2<br />

8d<br />

8d<br />

2<br />

4<br />

8d<br />

8d<br />

Lbs<br />

Lbs<br />

375<br />

155<br />

-- --<br />

260<br />

205<br />

105<br />

-- --<br />

170<br />

125<br />

-- --<br />

-- --<br />

-- --<br />

320<br />

130<br />

-- --<br />

220<br />

175<br />

90<br />

-- --<br />

140<br />

110<br />

-- --<br />

-- --<br />

-- --<br />

kN<br />

kN<br />

1.67<br />

0.69<br />

-- --<br />

1.16<br />

0.91<br />

0.47<br />

-- --<br />

0.76<br />

0.56<br />

-- --<br />

-- --<br />

-- --<br />

1.42<br />

0.58<br />

-- --<br />

0.98<br />

0.78<br />

0.40<br />

-- --<br />

0.62<br />

0.49<br />

-- --<br />

-- --<br />

-- --<br />

1) Factored resistances have been increased for short-term loading; 5) To achieve F1 loads in both directions, clips must be installed on<br />

no further increase is allowed. both sides of the trussand staggered to avoid nail interference.<br />

2) Truss must be bearing on top plate to achieve the factored resistances 6) Minimum nail embedment shall be 8 nail diameters (typ).<br />

under "Without Gap". 7) NAILS:<br />

New products or updated product information are designated in red font.<br />

<br />

<br />

<br />

<strong>USP</strong><br />

Stock No.<br />

HTC4<br />

Materials:<br />

Finish:<br />

See chart<br />

G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Do not fully set nails.<br />

• Locate nails into the centre of slots.<br />

Heavy Truss Deflection Clip – HTC4<br />

Slotted design allows truss to deflect without imposing load on wall below.<br />

Materials:<br />

Finish:<br />

Codes:<br />

16 gauge<br />

G90 galvanizing<br />

Load values are derived from data submitted to various<br />

North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Do not fully set nails.<br />

Fastener Schedule 2,4,5<br />

Plate Truss/Rafter<br />

Without Gap 3<br />

Factored Resistance (115%) 1<br />

3<br />

Without Gap 3 3<br />

Top Side<br />

F1 F2 F1 F2 F1 F2 F1 F2<br />

Steel<br />

Ref. No. Gauge Qty Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN<br />

HTC4,<br />

16 2 4 10d x 1-1/2 3 10d x 1-1/2 265 1.18 545 2.42 55 0.24 305 1.36 230 1.02 470 2.09 45 0.20 260 1.16<br />

S/HTC4<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Truss/Rafter must be bearing on top plate to achieve the allowable loads under "Without Gap".<br />

3) When installed with maximum 1-1/4" space between truss/rafter and top plate, use loads under "With 1-1/4" Gap".<br />

4) Minimum nail embedment shall be 8 nail diameters (typ).<br />

5) NAILS<br />

Blocking Supports – ZC series<br />

DF-L<br />

D<br />

S-F-P<br />

3 1 /2˝<br />

TR2<br />

2 1/2˝ 2 11/16˝ F2<br />

1 7/8˝<br />

F1<br />

Typical TR2 installation<br />

HTC4<br />

3 1 /4˝<br />

1 15 /16˝<br />

TR1<br />

1˝<br />

1 1/4˝ 2 3/4˝<br />

2˝<br />

F2<br />

NEW<br />

SIZE<br />

1 1 /4˝<br />

TR1T<br />

F1<br />

Typical HTC4<br />

installation<br />

4 1 /4˝<br />

1 3/4˝<br />

Plated Truss<br />

ZC clips secure blocking between joists or trusses which<br />

provides support for drywall or sheathing.<br />

Materials:<br />

Finish:<br />

See chart<br />

G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

1) Factored resistance shall not be increased for other load duration factors.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

red font.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

ZC4<br />

179<br />

<strong>USP</strong>2240-131<br />

H<br />

W<br />

ZC2<br />

Dimensions (in)<br />

Fastener Schedule 2,3<br />

Factored Resistance 1<br />

Header Blocking DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

<strong>USP</strong><br />

Steel<br />

Vertical Vertical Vertical Vertical<br />

Stock No. Ref. No. Gauge W H D Qty Type Qty Type 100% 100% 100% 100%<br />

ZC2 Z2 20 2-1/4 1-9/16 1-1/2 2 10d x 1-1/2 2 10d x 1-1/2 670 2.98 475 2.11<br />

ZC4 Z4 12 1-1/2 3-9/16 1-3/8 2 10d x 1-1/2 1 10d x 1-1/2 460 2.05 385 1.71<br />

ZC24 Z28 28 2-1/2 1-9/16 1-3/8 10d x 1-1/2 10d x 1-1/2 -- -- -- -- -- -- -- --<br />

ZC34 Z38 28 2-1/2 2-9/16 1-5/16 10d x 1-1/2 10d x 1-1/2 -- -- -- -- -- -- -- --<br />

Typical ZC installation


Truss Brace & Spacer (Stabilizer TM )<br />

The Stabilizer Truss Brace & Spacer provides temporary construction bracing in<br />

the roof and ceiling planes, as well as permanent lateral bracing for webs as<br />

specified by your truss engineering.<br />

The Stabilizer is easily installed by embedding the patented MII 20 teeth on the<br />

top flange straight into the edge of the truss member to be braced with a framing<br />

hammer. The side tabs are then secured by driving the teeth into the face of the<br />

truss member being braced.<br />

24 o.c.<br />

Odd<br />

Spacing<br />

Plated Truss<br />

Materials: 20 gauge<br />

Finish: G60 galvanizing<br />

Codes: Load values are derived from data submitted to various North<br />

American building code evaluators.<br />

Installation:<br />

• Use 31-16 for standard 16˝ o.c. spacing and 31-24 for standard 24˝ o.c. spacing.<br />

For odd spacing, cut and insert a solid block between the trusses.<br />

• Typically, The Stabilizer is installed at 6´– 8´ centres along the roof plane and<br />

10´– 15´ along the ceiling plane. (Refer to engineering specifications BCSI 1-03,<br />

published by The Truss Plate Institute for specific bracing requirements.)<br />

• The Stabilizer must be supplemented with diagonal bracing in the roof and ceiling<br />

planes and cross bracing in the web plane at required intervals.<br />

• Web forces are not to exceed 8000 lbs.<br />

• The Stabilizer is properly installed when the top flap and side tabs are flush<br />

with the member being braced.<br />

Important: The erection contractor is responsible for determining and<br />

installing the temporary bracing for the structure, including the trusses. It is<br />

most important for the installer to provide adequate means for bracing the first<br />

truss installed. The performance of the entire bracing system depends on the<br />

adequacy of the ground bracing or other means of bracing the first group of<br />

trusses installed. The building designer is responsible for the permanent<br />

bracing design of the overall structure including the truss. This includes the<br />

design of required supplemental diagonal and cross bracing.<br />

Temporary Construction<br />

Bracing Installation<br />

1 3 /8˝<br />

Flap<br />

25 1 /4˝<br />

31-24 Stabilizer<br />

22 1 /2˝<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Hammer here<br />

Side view<br />

1˝<br />

7/8˝<br />

73.19º<br />

Hammer here<br />

Chord<br />

attachment detail<br />

Web bracing<br />

installation<br />

Top view<br />

1 1 /2˝<br />

1 3 /8˝<br />

Standard Mil 20 punch<br />

<strong>USP</strong><br />

Stock No.<br />

O.C.<br />

Factored Axial Loads (Lbs.)<br />

Steel Spacing<br />

Tension<br />

Ref. No. Gauge (in) Tension with Fastener Compression<br />

1) 1 pound = 4.448N<br />

31-16 TSBR2-16 20 16<br />

31-24 TSBR2-24 20 24<br />

152 222 608<br />

2) Fastener shall be (1) 8d or 10d common wire nail inserted through nail slot.<br />

New products or updated product information are designated in red font.<br />

End view<br />

1 3 /8˝<br />

Tab<br />

1 3 /8˝<br />

7/8˝<br />

1˝<br />

1/4˝<br />

1 1 /2˝<br />

180<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Truss Spacers – TS & TSX series<br />

Truss spacers give framers fast and accurate spacing for<br />

trusses, rafters, or floor joists. The TS and TSX eliminate the<br />

need to mark layouts on bearing plates, improve installation<br />

speed, and help eliminate spacing errors. These spacers are<br />

light weight and compact.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

NEW<br />

SIZE<br />

Typical TSX installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Installation:<br />

• Use (1) 8d nail per end to fasten units to trusses, rafters, or<br />

floor joists.<br />

Important: These units provide spacing guides<br />

only. Do not rely on the TS or TSX for bracing.<br />

<strong>USP</strong><br />

Steel O. C. Overall Sections<br />

Joist Width Stock No. 1 Ref. No. Gauge Spacing (in) Length Per Piece<br />

1-1/2 TS -- -- 20 24 1<br />

1-1/2 TSX16 TSF2-16 22 16 8' 6<br />

1-1/2 TSX24 TSF2-24 22 24 10' 5<br />

1) TSX spacers are shipped folded.<br />

New products or updated product information are designated in red font.<br />

TSX multi-unit spacer<br />

TS single-unit spacer<br />

Plated Truss<br />

Drag Strut Connector – LDSC & DSC series<br />

Transfers lateral loads from girder truss into bearing walls.<br />

Materials: See chart<br />

Finish: <strong>USP</strong> primer<br />

Codes: Load values are derived from data submitted<br />

to various North American building code<br />

evaluators.<br />

10 1 /2˝<br />

Installation:<br />

• Use all specified fasteners. See Product<br />

Notes, page 10.<br />

• WS3 Wood Screw, 1 /4˝ dia. x 3˝ long,<br />

are supplied with DSC4 connector.<br />

2 1 /8˝<br />

2˝<br />

LDSC4L<br />

left shown<br />

7˝<br />

Typical DSC4R<br />

installation<br />

Fastener Schedule 2,3,4<br />

Factored Resistance (115%) 1<br />

Truss Top Plate<br />

DF-L<br />

S-P-F<br />

<strong>USP</strong><br />

Steel<br />

Compression Tension Compression Tension<br />

Stock No. Ref. No. Gauge Qty Type Qty Type Lbs kN Lbs kN Lbs kN Lbs kN<br />

LDSC4L/R -- -- 14 9 10d x 1-1/2 9 10d x 1-1/2 1700 7.56 1700 7.56 1475 6.56 1475 6.56<br />

DSC4L/R DSC5R/L-SDS3 3 16 WS3 16 WS3 6165 27.42 6140 27.31 5305 23.60 5280 23.49<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake;<br />

reduce for other load durations in accordance with the code.<br />

<br />

3) Minimum nail embedment shall be 8 nail diameters (typ).<br />

4) NAILS<br />

3˝<br />

21˝ 3 1 /4˝<br />

DSC4R<br />

right shown<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 181<br />

<strong>USP</strong>2240-131


Alternate Installations<br />

Backer block<br />

installation<br />

Wood blocking used to achieve full design<br />

load value of a face mount hanger attached to<br />

a carrying member.<br />

(Blocking to be designed by truss<br />

designer or engineer of record)<br />

Panel point<br />

installation<br />

Connection with face mount hanger<br />

attaching to a truss panel point.<br />

(Hanger nails that do not penetrate wood<br />

in panel point provide no<br />

load resistance)<br />

Reduce load according to the code.<br />

Plated Truss<br />

Wood blocking<br />

JUS26 pg. 91<br />

THDH28-2<br />

pg. 166-167<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

• Wood blocking should be of similar<br />

size/grade as the truss member to which it is<br />

attached. The blocking should be designed to<br />

act as one unit with truss members.<br />

• Truss designer shall approve blocking<br />

size/grade, fasteners required, and<br />

application.<br />

• All fasteners used to attach wood<br />

blocking should be independent of the<br />

fasteners in the truss hanger.<br />

THDH26-2<br />

pg. 166-167<br />

Filler block<br />

installation<br />

Wood filler blocking used for<br />

supported member width less<br />

than hanger width.<br />

(Blocking and blocking<br />

fasteners/quantity to be<br />

designed by truss designer or<br />

engineer of record)<br />

GT4T6BH<br />

pg. 174<br />

Filler Blocking<br />

Filler Blocking<br />

182<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Bridging – N & O Series<br />

O – The O series spans three joists in under/over installation. Prong teeth in the<br />

centre help reduce nailing.<br />

N – The N series spans two joists per unit. Can be used for bridging or bracing I-Joists.<br />

See chart.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to various North<br />

American building code evaluators.<br />

Installation:<br />

• Use specified fasteners in models with fastener requirements.<br />

• Install prior to subfloor sheathing. Use (2) 8d x 11⁄2˝ nails at each end. Fully seat nails<br />

to avoid any movement against the bridging and subsequent floor noise.<br />

Dimensions (in) Fastener Schedule 3,4 Joist<br />

<strong>USP</strong><br />

Steel<br />

Spacing<br />

Stock No. Ref. No. Gauge W L Qty Type O.C. (in) 1,2<br />

N16 LTB20, TB20 22 3/4 19-3/4 4 8d x 1-1/2 16<br />

N27 TB27 20 3/4 26-13/16 4 8d x 1-1/2 -- --<br />

N30 TB30 20 3/4 29-13/16 4 8d x 1-1/2 -- --<br />

N36 TB36 20 3/4 35-13/16 4 8d x 1-1/2 -- --<br />

N42 TB42 20 3/4 42 4 8d x 1-1/2 -- --<br />

N48 TB48 20 3/4 48 4 8d x 1-1/2 -- --<br />

N54 TB54 20 3/4 54 4 8d x 1-1/2 -- --<br />

N56 TB56 20 1 56 4 8d x 1-1/2 -- --<br />

N60 TB60 20 1 60 4 8d x 1-1/2 -- --<br />

O16 -- -- 18 1 44 4 8d x 1-1/2 16<br />

O40 LTB40 22 3/4 39-3/4 4 8d x 1-1/2 16<br />

1) For joist spacing, refer to the Joist Installation chart.<br />

<br />

wider joist applications.<br />

<br />

3) NAILS<br />

W<br />

Typical O<br />

installation<br />

O<br />

L<br />

Joist Installations<br />

Sized for Joist-to-Joist X Bridging<br />

I-Beam<br />

Joist Spacing 1<br />

Height <br />

7-1/4 -- --<br />

N16/O16<br />

/O40<br />

-- -- -- -- -- -- -- -- -- -- -- -- -- --<br />

9-1/4 N16<br />

N16/O16<br />

/O40<br />

N27 N27/N30 N36 N36/N42 N42 N48 N54/N56<br />

9-1/2 N16 N16 N27 N27/N30 N36 N36/N42 N42 N48 N54/N56<br />

10 N16 N16 N27 N27/N30 N36 N36/N42 N42 N48 N54/N56<br />

11-1/4 N16 N16 N27 N30 N36 N36/N42 N42 N48 N54/N56<br />

11-7/8 N16 N27 N27 N30 N36 N36/N42 N42 N48 N54/N56<br />

12 N16 N27 N27 N30 N36 N36/N42 N42 N48 N54/N56<br />

14 N16 N27 N27/N30 N30 N36/N42 N36/N42 N42 N48 N54/N56<br />

16 N27 N27 N27/N30 N30 N36/N42 N42 N42/N48 N48/N54 N54/N56<br />

18 N27 N27/N30 N30 N36 N36/N42 N42 N42/N48 N48/N54 N54/N56<br />

20 N27/N30 N27/N30 N30 N36 N42 N42 N42/N48 N48/N54 N54/N56/N60<br />

22 N27/N30 N30 N36 N36/N42 N42 N42/N48 N48 N54/N56 N54/N56/N60<br />

24 N30 N36 N36 N36/N42 N42 N42/N48 N48 N54/N56 N56/N60<br />

26 N30/N36 N36 N36/N42 N42 N42/N48 N48 N48/N54 N54/N56 N56/N60<br />

28 N36 N36/N42 N36/N42 N42 N42/N48 N48 N48/N54 N54/N56 N60<br />

30 N36/N42 N36/N42 N42 N42/N48 N48 N48 N48/N54/N56 N54/N56/N60 N60<br />

32 N36/N42 N42 N42 N42/N48 N48 N48/N54 N54/N56 N54/N56/N60 N60<br />

W<br />

Typical N<br />

installation<br />

N<br />

L<br />

Miscellaneous<br />

All models require (2) 8d x 1-1/2 nails at each end.<br />

<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 183<br />

<strong>USP</strong>2240-131


Bridging – MB16 & MBG series<br />

MBG – Grip tooth bridging. Features special teeth which grip joists<br />

and provide easy single-nail installation. Can be installed after<br />

subfloor is in place.<br />

MB16 – Snap-on, no-nail bridging can be placed in existing floor<br />

systems where joist movement is suspected. Two-piece<br />

construction creates a solid diagonal brace against joist movement.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use specified fasteners in models with fastener requirements.<br />

• MBG – May be installed before or after sheathing. Position the<br />

unbent end of the bridging unit near the top of the joist and drive<br />

prongs into wood with a hammer blow to the heel of the bent end.<br />

Wedge bent end near the lower edge of the opposite joist, set teeth<br />

into wood with hammer blow. Nail holes are provided at the bent<br />

end if prongs are damaged during installation. Fully seat nails to<br />

avoid any movement against the bridging and subsequent floor<br />

noise.<br />

• MB16 – Two-piece unit is shipped as one piece. Bend unit in<br />

center up and down to break into two pieces. Slide narrower piece<br />

inside wider piece, setting the end tab into slot appropriate for joist<br />

spacing. Setting one prong end near the top of one joist and the<br />

opposite prong end near the bottom of the opposite joist, pull down<br />

on the center of the bridging until the wider piece snaps into place<br />

over the narrow piece and creates a rigid, one-piece bridging unit.<br />

Wear gloves during installation.<br />

W<br />

MBG<br />

L<br />

Step 1<br />

Step 2<br />

Typical MBG<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

MB16<br />

Typical MB16<br />

installation<br />

Miscellaneous<br />

Joist<br />

Spacing <strong>USP</strong><br />

Steel<br />

Dimensions (in) Fastener Schedule 2,3<br />

Joist Size O.C. (in) 1 Stock No. Ref. No. Gauge W L Qty Type<br />

2 x 8 12 MBG812 NCA2X8-12 22 15/16 11-3/4 1 8d x 1-1/2<br />

2 x 10 12 MBG1012 NCA2X10-12 22 15/16 12-3/4 1 8d x 1-1/2<br />

2 x 12 12 MBG1212 NCA2X12-12 22 15/16 14 1 8d x 1-1/2<br />

2 x 14 12 MBG1412 -- -- 22 15/16 16 1 8d x 1-1/2<br />

2 x 16 12 MBG1612 -- -- 22 15/16 17 1 8d x 1-1/2<br />

2 x 8 - 10 - 12 16 MB16 -- -- 22 11/16 -- -- -- -- -- --<br />

2 x 8 16 MBG816 NCA2X8-16 22 15/16 15-9/16 1 8d x 1-1/2<br />

2 x 10 16 MBG1016 NCA2X10-16 22 15/16 16-5/16 1 8d x 1-1/2<br />

2 x 12 16 MBG1216 NCA2X12-16 22 15/16 17-1/4 1 8d x 1-1/2<br />

2 x 14 16 MBG1416 -- -- 22 15/16 18-7/16 1 8d x 1-1/2<br />

2 x 16 16 MBG1616 -- -- 22 15/16 19-5/8 1 8d x 1-1/2<br />

2 x 8 24 MBG824 -- -- 22 1-5/16 23-1/2 1 8d x 1-1/2<br />

2 x 10 24 MBG1024 -- -- 22 1-5/16 24 1 8d x 1-1/2<br />

2 x 12 24 MBG1224 -- -- 22 1-5/16 24-3/4 1 8d x 1-1/2<br />

2 x 14 24 MBG1424 -- -- 22 1-5/16 25-5/8 1 8d x 1-1/2<br />

2 x 16 24 MBG1624 -- -- 22 15/16 26-5/8 1 8d x 1-1/2<br />

<br />

<br />

3) NAILS<br />

184<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Deck Clip – DC50<br />

Connects deck boards to joists without face nails or screws. Eliminates rust stains on decks, as<br />

well as splintering or wood rot caused by screw or nail “craters”. The DC50-TZ works like tonguein-groove<br />

flooring and is easy to install. Raised dimples on the clip provide consistent spacing<br />

between deck boards.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: 20 gauge<br />

Finish: G-185 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Fits 11/8˝ or thicker decking.<br />

• Fasten the first deck board onto the joists by toenailing up through the joist below into the deck<br />

board. Be sure no sharp points protrude above the deck surface. For subsequent deck board<br />

rows, nail DC50-TZs onto the deck board edge, positioned 2˝ from each joist. Slide the deck<br />

board along the joist until the DC50-TZ “lip” is under the previously laid deck board. Toenail the<br />

deck board’s exposed edge to the joist. Repeat until decking is completed. The last deck board<br />

will require toenailing up from below to secure the outside edge.<br />

Joist<br />

1). Use 10d x 3˝ HDG nails<br />

to toenail both edges of first<br />

board.<br />

DeckBoard<br />

2). Use 8d x 1-1/2˝ HDG<br />

nails to attach DC50 Clip to<br />

edge of deck board. Space<br />

2˝ from each joist.<br />

Typical<br />

DC50-TZ<br />

installation<br />

DC50-TZ<br />

Joist<br />

3). Slide deck board with<br />

attached DC50 Clip under<br />

previously-installed deck<br />

board.<br />

Joist<br />

4) Use 10d x 3˝ HDG nails<br />

to toenail front edge of<br />

board at each joist. Repeat<br />

Steps 2-4 until deck is<br />

complete.<br />

<strong>USP</strong><br />

Steel<br />

Fastener Schedule 1,2,3<br />

Stock No. Ref. No. Gauge Qty Type<br />

DC50-TZ DBT1Z 20 1 8d x 1-1/2 HDG<br />

<br />

<br />

3) NAILS<br />

Miscellaneous<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 185<br />

<strong>USP</strong>2240-131


Protection Plates – ICPL series, KNS1, & PL4<br />

Easy-to-install plates protect plumbing and power/communication wiring<br />

from nail or screw penetration.<br />

ICPL58 – Installs with nails.<br />

KNS1 & PL4 – Prongs allow for quick installation.<br />

Materials: 16 gauge<br />

Finish: ICPL516-TZ – G-185 galvanizing;<br />

All others – Galvanized<br />

Options: ICPL58 is available in Triple Zinc. To order, add TZ to<br />

stock number, as in ICPL58-TZ.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

Typical<br />

KNS1 & PL4<br />

installation<br />

H<br />

H<br />

Typical ICPL58<br />

installation<br />

W<br />

H<br />

ICPL58<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

W<br />

W<br />

KNS1<br />

PL4<br />

Typical ICPL516-TZ<br />

installation<br />

W<br />

H<br />

Miscellaneous<br />

<strong>USP</strong><br />

Steel<br />

Dimensions (in) Fastener Schedule 1,2<br />

Stock No. Ref. No. Thickness W H Qty Type<br />

ICPL58 S/PSPN58 1/16 8-1/16 5 4 8d or prongs<br />

PL4 NS2 1/16 2 5 -- -- prongs<br />

KNS1 NS1 1/16 1-1/2 3 -- -- prongs<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) NAILS:<br />

<strong>USP</strong><br />

Stock No.<br />

ICPL516-TZ<br />

Dimensions (in)<br />

Fastener Schedule 2,3 Factored Uplift Resistance 1<br />

Steel<br />

Installation<br />

DF-L S-P-F<br />

Ref. No. Thickness W H Type Qty Type Lbs kN Lbs kN<br />

16 5<br />

Sill Plate 12 16d HDG + prongs 1405 6.25 1205 5.36<br />

Double Top Plate 16 16d HDG + prongs 1870 8.32 1600 7.12<br />

PSPN516Z,<br />

<br />

<br />

1) Factored uplift resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS<br />

ICPL516-TZ<br />

186<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Wall Bracing – RWB, WB, WBC, & WBT series<br />

RWB – Flat bracing conveniently packaged in a handy roll out dispenser.<br />

Perfect for unexpected job site shortages. The 35-pound dispenser pack fits<br />

easily into a truck bed for transport. Pre-embossed snap-off points can be<br />

broken off by hand (wear gloves for safety).<br />

WB – A flat style bracing engineered to easily nail to studs. No cutting or fitting<br />

needed.<br />

WBC – The L-shaped design for additional strength and rigidity.<br />

WBT – Rolled edges and T-style design gives the WBT strength, rigidity, and<br />

eliminates sharp, sheared edges.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Bracing is a framing aid, not a substitute for structural shearwall components.<br />

• RWB & WB – Use with 16˝ or 24˝ o.c. studs. Install in pairs forming an “X” or<br />

opposing “V” at each end of a maximum 25-foot long wall panel.<br />

Steps: Square the panel. Straighten any kinks in bracing caused by handling.<br />

Lay bracing on the panel flush to the top of top plate and flush to the<br />

bottom of the bottom plate. Secure bracing to the top plate and bottom<br />

plate using 16d nails (WB) or 8d nails (RWB). Position second bracing at<br />

an angle opposite to the first brace to form an “X” and secure to top and<br />

bottom plate as with the first bracing. Using 8d nails, secure bracing to all<br />

intersecting studs.<br />

• WBC & WBT – Use with 16˝ o.c. studs. Install one brace at each end of wall<br />

section, not exceeding 25 feet, in an opposing “V” pattern. Use a length of the<br />

bracing as a straight web to mark studs. Cut a saw kerf 5⁄8˝ deep (1˝ deep for<br />

WBC). Insert the bracing web into the saw kerf, and drive one nail into the top<br />

plate. Raise the wall section into place and plumb. Finish<br />

fastening according to the nail schedule.<br />

Dimensions (in) Fastener Schedule 2,3<br />

<strong>USP</strong><br />

Steel<br />

Pieces Wall Install<br />

Each Plate Each Stud<br />

Stock No. 1 Ref. No. Gauge W L Per Roll Height Angle Qty Type Qty Type<br />

RWB96 WB106C 16 1-1/4 15 8' 60° 4 8d 1 8d<br />

RWB114 WB126C 16 1-1/4 12 8' 45° 4 8d 1 8d<br />

RWB143 WB143C 16 1-1/4 10 10' 45° 4 8d 1 8d<br />

WBC10 RCWB10 18 15/16 -- -- 8' 60° 2 16d 1 8d<br />

WBC12 RCWB12 18 15/16 -- -- 8' 45° 2 16d 1 8d<br />

WBT10 TWB10 22 1-3/8 -- -- 8' 60° 4 8d 1 8d<br />

WBT12 TWB12 22 1-3/8 -- -- 8' 45° 4 8d 1 8d<br />

WBT14<br />

RCWB14,<br />

TWB14<br />

22 1-3/8 -- -- 10' 45° 4 8d 1 8d<br />

WB106 WB106 16 1-1/4 -- -- 8' 60° 3 16d 1 8d<br />

WB126 WB126 16 1-1/4 -- -- 8' 45° 3 16d 1 8d<br />

1) These products substitute for code prescribed 1 x 4 let-in bracing.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS<br />

W 1<br />

Typical RWB, WB<br />

installation<br />

RWB pre-embossed<br />

snap-off points<br />

W 1<br />

L<br />

WB<br />

W 2<br />

Typical WBC / WBT<br />

installation<br />

Miscellaneous<br />

L<br />

W1<br />

L<br />

WBC<br />

WBT<br />

9/16˝<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 187<br />

<strong>USP</strong>2240-131


Fence Post <strong>Connectors</strong> – SFP & SMP series<br />

Take the work out of fence post installation and repair with the<br />

Speedpost, SFP30, and Speedmender, SMP. The Speedpost is used to<br />

install 4 x 4 fence posts without digging post holes or pouring concrete.<br />

The Speedmender plates act as reinforcement brackets for rotted or<br />

damaged fence posts.<br />

SFP30 – For 6´ nominally sized 4 x 4 fence posts.<br />

SMP – Available for nominally sized 4 x 4 posts.<br />

Miscellaneous<br />

Materials: 13 gauge<br />

Finish: Paint<br />

Installation:<br />

• Step-by-step installation instructions are labeled onto each product.<br />

SFP :<br />

1. Using a wood block, hammer theSpeedpost® into the ground with<br />

moderate but firm blows.<br />

2. As the Speedpost® is driven in, use a level to check positioning.<br />

3. When the underside of the post box reaches the ground, insert the<br />

post in the socket and secure using enclosed (3) Hot-dip galvanized<br />

screws.<br />

SMP :<br />

1. Remove fencing materials which interfere with SpeedMender <br />

installation.<br />

• Concrete Installation: Remove dirt to expose existing concrete,<br />

allowing SpeedMender to be driven into the concrete (concrete<br />

should be intact or the broken pieces removed) alongside the post<br />

where it emerges from the concrete.<br />

• Ground Installation: Dig into dirt 6˝-8˝ around post. This will provide<br />

a cavity for concrete to be added after SpeedMender is installed.<br />

2. Place tip of SpeedMender against post where it enters the ground.<br />

Hold the top of the SpeedMender at a slight angle to the post to<br />

begin driving.<br />

3. Use a sledge hammer to strike the wedge on the SpeedMender ,<br />

positioning it along the face of the post. Once started, force top of<br />

SpeedMender against the post and continue driving until the wedge<br />

enters between ground or concrete and post.<br />

4. Nail SpeedMender to the post using 10d galvanized nails. Optional:<br />

1/2˝ diameter bolt may be used to bolt SpeedMender for additional<br />

support.<br />

5. Install SpeedMender on opposite side following above directions.<br />

• Concrete Installation: If conditions permit, extra support is possible<br />

by pouring additional concrete into the hole around post and<br />

SpeedMender.<br />

• Ground Installation: Pour concrete into hole around post and<br />

SpeedMender. Allow concrete to set before reattaching previously<br />

removed fencing material.<br />

30˝<br />

Typical SFP30<br />

installation<br />

28 1 /16˝<br />

4 ˝<br />

SFP30<br />

5 5 /8˝<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

SMP<br />

<strong>USP</strong><br />

Stock No. Ref. No.<br />

SFP30 FPBS44<br />

SMP FPBM44E<br />

188<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Stud Shoes – STS series<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Stud shoes reinforce joists, plates, studs, or rafters which have<br />

been drilled or notched during construction.<br />

Materials: 16 gauge<br />

Finish: G90 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• STS units are not structurally rated and should not be used<br />

as a total member replacement in structural applications.<br />

• For use with 2˝ O.D. pipe.<br />

<strong>USP</strong><br />

Steel<br />

Dimension (in) Fastener Schedule 1,2,3<br />

Stock No. Ref. No. Gauge Description W Qty Type<br />

STS1 SS1.5 16 Single Stud 1-9/16 10 10d x 1-1/2<br />

STS2 SS3 16 Double Stud 3-1/16 12 10d<br />

STS3 SS4.5 16 Triple Stud 4-9/16 14 10d<br />

<br />

2) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

3) NAILS<br />

Typical STS1<br />

installation<br />

2 5 /8˝<br />

2 1 /2˝<br />

W<br />

STS<br />

5˝<br />

Bolt Down – BD series<br />

Anchors 4 x 4 posts to wood or concrete surface.<br />

Materials: 13 gauge<br />

Finish: Paint<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

<strong>USP</strong><br />

Steel Fastener Schedule<br />

Post Size Stock No. Ref. No. Gauge Qty Lag Bolts<br />

4 x 4 BD FPBB44 13 3 1/4" x 1-1/2" HDG<br />

Typical BD<br />

installation<br />

Miscellaneous<br />

4 ˝<br />

5 5 /8˝<br />

BD<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 189<br />

<strong>USP</strong>2240-131


Fence Brackets – ERB24, FB, FC & FRB series<br />

ERB24 – Designed to mount prefabricated fence<br />

sections and works with 2x4 horizontal section<br />

rails.<br />

FB26 – Secures 2x6 rails to wood posts.<br />

FRB24 – Secures continuous 2x4 rails to wood<br />

posts. Prepunched holes allow installers to splice<br />

2x4 rail ends within the bracket.<br />

Materials: See chart<br />

Finish: G-185 galvanizing<br />

Installation:<br />

• Use all specified fasteners.<br />

See Product Notes, page 10.<br />

FB14-TZ<br />

1 9 /16˝<br />

W H<br />

FRB24-TZ<br />

H<br />

W<br />

FC24-TZ<br />

Typical FRB24-TZ<br />

installation<br />

Typical FC24-TZ<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

2 3 /8˝<br />

W<br />

H<br />

1 1 /2˝<br />

FB23-TZ<br />

1 3 /16˝<br />

ERB24-TZ<br />

Typical ERB24-TZ<br />

installation<br />

NEW<br />

Miscellaneous<br />

FB26-TZ<br />

Dimensions (in)<br />

Fastener Schedule 2,3<br />

Factored Resistance 1<br />

<strong>USP</strong><br />

Steel<br />

DF-L<br />

S-P-F<br />

Rail Size Stock No. Ref. No Gauge W H Qty Rail Qty Post Unit Download F1 Download F1<br />

1 x 4 FB14-TZ -- -- 20 3/4 3-1/2 3 14 ga. x 3/4 HDG 2 8d x 1-1/2 HDG -- -- -- -- -- -- -- -- -- --<br />

2 x 3 FB23-TZ -- -- 20 1-9/16 2-3/8 3 8d x 1-1/2 HDG 4 8d x 1-1/2 HDG -- -- -- -- -- -- -- -- -- --<br />

ERB24-TZ -- -- 18 1-1/2 3-9/16 4 8d HDG 3 8d HDG -- -- -- -- -- -- -- -- -- --<br />

2 x 4 FC24-TZ<br />

FB24, FB24Z,<br />

FBR24, FBR24Z<br />

20 1-9/16 3 3 6d HDG 2 8d HDG -- -- -- -- -- -- -- -- -- --<br />

FRB24-TZ -- -- 18 1-9/16 3-9/16 2 10d x 1-1/2 HDG 4 10d HDG -- -- -- -- -- -- -- -- -- --<br />

2 x 6 FB26-TZ FB26 18 1-9/16 5<br />

4 10d x 1-1/2 HDG 4 10d x 1-1/2 HDG<br />

Lbs 550 700 390 495<br />

kN 2.45 3.11 1.73 2.20<br />

4 LL915 4 LL915<br />

Lbs 780 715 550 505<br />

kN 3.47 3.18 2.45 2.25<br />

1) Factored resistances have been increased 15% for short-term loading such as wind and earthquake; no further increase is permitted.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ.).<br />

3) NAILS<br />

<br />

New products or updated product information are designated in red font.<br />

Typical FB26-TZ<br />

installation<br />

190<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Pipe Rail Ties – PRT series<br />

PRT15-TZ – is for 1 ⅝ " vertical pipe posts (1⅞" outside pipe<br />

diameter). Can be field bent 90° for outside corner installations.<br />

PRT2-TZ / PRT2H-TZ – is for 2” vertical pipe posts (2⅜" outside<br />

pipe diameter). Can be field bent 90° for outside corner installations.<br />

PRTIC2-TZ – is for inside corner installations. For 2" vertical pipe<br />

posts (2⅜" outside pipe diameter).<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: See chart<br />

Finish: G-185 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• PRT15-TZ, PRT2H-TZ and PRTIC2-TZ - ¼" Self Tapping Bolts are<br />

supplied with PRT models.<br />

• Install self tapping bolts with ⅜" socket in predrilled holes.<br />

• PRT2-TZ fastens with (1) ¼" carriage bolt and nut (included) for<br />

tightening PRT2-TZ to pipe and (4) ¼" lag bolts for attaching<br />

tie to rail.<br />

• Install 3 to 4 PRT's per pipe.<br />

• PRT15-TZ, PRT2-TZ and PRT2H-TZ may be bent once to fit<br />

corner and angled conditions.<br />

NEW<br />

Typical PRT2H-TZ<br />

installation<br />

PRT15-TZ & PRT2-TZ similar<br />

1 9/16"<br />

4 11/16"<br />

PRT2-TZ<br />

2"<br />

2 3/8"<br />

6 3/8"<br />

2 ½"<br />

1½"<br />

2 3/8"<br />

Typical PRTIC2-TZ<br />

installation<br />

PRT2H-TZ<br />

4 3/16"<br />

2 3/8"<br />

PRTIC2-TZ<br />

2 ½"<br />

6 7/16"<br />

Field bent<br />

application<br />

2 9/16" 1½"<br />

1 7/8"<br />

PRT15-TZ<br />

Miscellaneous<br />

Fastener Schedule 1<br />

<strong>USP</strong><br />

Steel<br />

Pipe<br />

Rail<br />

Stock No. Ref. No. Gauge Qty Type Qty Type<br />

PRT15-TZ PGT1.5Z-R 12 1 4 <br />

PRT2-TZ PGT2E 16 1 4 <br />

PRT2H-TZ<br />

PGT2Z-R,<br />

PGT2A<br />

12 1 4 <br />

PRTIC2-TZ 12 2 4 <br />

<br />

<br />

<br />

<br />

red font.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

<strong>USP</strong>2240-131<br />

191


Deck Tie Back – DTB<br />

Deck Tie Back reinforces the connection of rail posts to a<br />

deck. Also provides lateral strength of deck-to-ledger<br />

attachment by securing deck to house framing.<br />

Materials: 14 gau ge<br />

Finish: G-185 galvanizing<br />

Options: DTB is available in Stainless Steel. To order,<br />

add SS to stock number, as in DTB-SS.<br />

Codes: Load values are derived from data<br />

submitted to various North American<br />

building code evaluators.<br />

Installation:<br />

• Use all specified fasteners.See Product Notes, page 10.<br />

• Install with <strong>USP</strong>’s THR 1/2" threaded rod or equivalent.<br />

• Position DTB-TZ on deck joist in a location where the 1/2"<br />

threaded rod or bolt may be threaded through the bolt hole.<br />

• Drive WS15-GC wood screws into joist.<br />

• Re-install threaded rod or anchor bolt. Secure with washer<br />

and nut.<br />

• Tighten anchor bolt nuts finger tight snug to base plus 1⁄3<br />

to 1⁄2 additional turns with wrench. To prevent<br />

loosening of the anchor nut during critical loading, use a<br />

locking nut or tighten a second nut over the first to lock nuts<br />

in place.<br />

DTB-TZ<br />

Typical DTB-TZ<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

½" THR<br />

Threaded Rod<br />

pg. 29<br />

Typical DTB-TZ<br />

Deck to ledger<br />

installation<br />

Miscellaneous<br />

<strong>USP</strong><br />

Stock No.<br />

Fastener Schedule 2,3<br />

Factored Resistance<br />

Rod / Bolt<br />

CL<br />

DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Steel Anchor<br />

Wood<br />

Ref. No. Gauge Dia. (in) (in) Qty Screws 100% 115% 1 100% 115% 1 100% 115% 1 100% 115% 1<br />

DTB-TZ<br />

DTT2Z,<br />

DTT2Z-SDS2.5, 14 1/2 1-1/8 8 WS15-GC 2640 2640 11.74 11.74 2220 2220 9.88 9.88<br />

FSC<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake;<br />

reduce for other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) WS15-GC Wood Screws are 1/4" dia. x 1-1/2" long and are included with DTB-TZ Deck Tie-Backs.<br />

192<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Deck Ties – SDJT14 & SDPT series<br />

SDPT – Connects 2 x 4 stair posts and 4 x 4 posts to deck rim joist or<br />

stair stringers.<br />

SDJT14 – Secures 2x joists to posts.<br />

Materials: 14 gauge<br />

Finish: G-185 galvanizing<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• SDPT5-TZ & SDPT7-TZ – Install units in pairs on 2x4 (SDPT5-TZ)<br />

or 4x4 (SDPT7-TZ) post. Space the connectors 5˝ apart from centre<br />

to centre on the post. Use through bolts to fasten connectors to rim<br />

joist or stringer. Do not use lag bolts. Fasten to post with specified<br />

nails (see chart).<br />

• SDJT14-TZ – Use with 2x lumber for joists (minimum height is<br />

2x4). Install with either specified nails or through bolts. Do not use<br />

lag bolts. To ease installation, attach to 4x4 post first.<br />

Typical SDJT14-TZ<br />

installation<br />

3 1 /8˝<br />

3 1 /8˝<br />

2 3 /4˝<br />

Typical SDPT7-TZ<br />

installation<br />

1 1 /2˝<br />

3 1 /2˝<br />

3 1 /2˝<br />

SDJT14-TZ<br />

SDPT7-TZ<br />

1 1 /2˝<br />

1 1 /2˝<br />

3 1 /2˝<br />

SDPT5-TZ<br />

Fastener Schedule<br />

<strong>USP</strong><br />

Steel<br />

Nails 1,3 Bolts 2 DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Post Size Stock No. Ref. No. Gauge Qty Type Qty Dia. Nails Bolts Nails Bolts Nails Bolts Nails Bolts<br />

2 x 4 SDPT5-TZ DPT5Z 14 5 10d x 1-1/2 HDG 2 3/8 HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />

4 x 4 SDPT7-TZ DPT7Z 14 5 10d x 1-1/2 HDG 2 3/8 HDG -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --<br />

4 x 4 SDJT14-TZ DJT14Z 14 8 16d HDG 2 3/8 HDG 1615 2015 7.18 8.96 1355 1695 6.03 7.54<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) Bolts shall conform to ASTM A 307 or better.<br />

3) NAILS<br />

Factored Resistance (100%)<br />

Miscellaneous<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 193<br />

<strong>USP</strong>2240-131


Concealed Stringer Hanger – CSH-TZ<br />

The CSH-TZ concealed stringer hanger provides a method of connecting<br />

a stair stringer with a hidden hanger. The seat of the hanger is adjustable<br />

to match the slope of the stair stringer. The reversible design allows the<br />

connector to be used on the left, right, or interior stringers. The CSH-TZ<br />

may be used with <strong>USP</strong>’s SCA Stair Angles for a complete, easy-to-use stair<br />

framing solution.<br />

Materials: 18 gauge<br />

Finish: G-185 galvanizing<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Products Notes, page 10.<br />

• Bend angle only once.<br />

Steps:<br />

1. Attach CSH-TZ to header with tabs positioned towards the inside of the<br />

stringer member.<br />

2. Adjust the seat of the CSH-TZ to match the slope of the stringer<br />

member. Diamond shaped holes in the connector allow temporary<br />

installation of woodscrews to aid in installation of the CSH-TZ.<br />

3. Install 10d x 1 1/2˝ HDG nails into the stringer and header members.<br />

Typical CSH -TZ<br />

installation<br />

1 7 /16˝<br />

1 1 /2˝<br />

5˝<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Adjustable<br />

5˝<br />

CSH-TZ<br />

Miscellaneous<br />

Header<br />

Fastener Schedule 2,3<br />

DF-L (Lbs)<br />

Factored Resistance<br />

S-P-F (Lbs)<br />

<strong>USP</strong><br />

Steel<br />

Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1 Vertical Uplift 1<br />

Stock No. Ref. No. Gauge Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

CSH-TZ LSCZ 18 8 10d x 1-1/2 HDG 5 10d x 1-1/2 HDG 1455 545 6.47 2.42 1030 385 4.58 1.71<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase is allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS:<br />

Joist<br />

DF-L (kN)<br />

S-P-F (kN)<br />

194<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Stair Angles – SCA series<br />

Stair angles simplify stair construction. There is no need to calculate and notch<br />

stair stringers. Stronger and safer than wood blocking, and the angle and<br />

fasteners are hidden from view.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: 12 gauge<br />

Finish: G-185 galvanizing;<br />

SCA9-GC – Gold Coat<br />

Codes: Load values are derived from data submitted to<br />

various North American building code evaluators.<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Use the SCA9-TZ or single 2x10 stair treads.<br />

• Use the SCA10-TZ for double 2 x 6 stair treads.<br />

• To calculate stair construction do the following:<br />

1. Find the number of steps needed by taking the vertical drop from the deck surface<br />

grade. Divide by 7. Round off to the nearest whole number. (Ex: Vertical drop<br />

of divided by 7 equals 5.57˝ rounded off is 6˝)<br />

2. Find the step rise by dividing the vertical drop by the number of steps (39˝<br />

divided by 6 = 6.5˝)<br />

3. Find the step run by measuring the depth of your treadboard (Ex: (2) 2x6s<br />

have of 111⁄4˝)<br />

4. Find the stairway span by multiplying the run by the number oftreads minus<br />

one (Ex: 111⁄4˝ x 5 = 561⁄4˝)<br />

• Using the above calculations, mark stair angle locations on each stringer. Attach<br />

a stair angle to the inside of each stringer at the marked locations. Attach stringers<br />

to deck rim joist and railing posts. Position treadboards on angles and fasten from<br />

below.<br />

Typical SCA9-TZ<br />

installation<br />

L<br />

SCA9-TZ<br />

W<br />

W<br />

Typical SCA10-TZ<br />

installation<br />

Dimensions (in) Fastener Schedule 2 Factored Download Resistance (100%) 1<br />

DF-L S-P-F<br />

<strong>USP</strong><br />

Steel<br />

Stock No. Ref. No. Gauge w L Qty Type Lbs kN Lbs kN<br />

SCA9-TZ TA9Z 12 1-3/8 9 6 1925 8.56 1365 6.07<br />

-- -- 12 1-3/8 9 6 1925 8.56 1365 6.07<br />

SCA10-TZ TA10Z 12 1-3/8 10 8 1925 8.56 1365 6.07<br />

1) Loads assume rise over run of 7/11.<br />

<br />

Miscellaneous<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 195<br />

<strong>USP</strong>2240-131


Step Flashing – SF8<br />

Pre-sized, ready to install, versatile flashing unit. Ideal for roof<br />

applications.<br />

Materials: 28 gauge<br />

Finish: G90 galvanizing<br />

<strong>USP</strong><br />

Steel Dimensions (in)<br />

Stock No. Ref. No. Gauge W H L<br />

SF8 -- -- 28 3-1/2 3-1/2 8<br />

Typical SF installation<br />

L<br />

W<br />

H<br />

SF<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Fence Rail Hanger – FPH24-TZ<br />

The FPH24-TZ attaches 2 x 4 fence rails to wood posts. The<br />

Triple Zinc (G-185) galvanized finish offers superior corrosion<br />

resistance in outdoor applications and/or with treated wood.<br />

Materials: 18 gauge<br />

Finish: G-185 galvanizing<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• Fasteners need to be Hot-Dip Galvanized for outdoor<br />

applications and for use with preservative treated wood.<br />

Typical FPH24-TZ<br />

installation<br />

Miscellaneous<br />

3˝<br />

1 15 /16˝<br />

1 9 /16˝<br />

FPH24-TZ<br />

196<br />

Fastener Schedule 2,3<br />

Factored Resistance<br />

Header<br />

Joist<br />

DF-L (Lbs) DF-L (kN) S-P-F (Lbs) S-P-F (kN)<br />

Joist <strong>USP</strong><br />

Steel<br />

Bearing Uplift 1 Bearing Uplift 1 Bearing Uplift 1 Bearing Uplift 1<br />

Size Stock No. Ref. No. Gauge Qty Type Qty Type 100% 115% 100% 115% 100% 115% 100% 115%<br />

2 x 4 FPH24-TZ -- -- 18<br />

3 8d x 1-1/2 HDG 3 8d x 1-1/2 HDG 410 545 1.82 2.42 350 465 1.56 2.07<br />

3 10d x 1-1/2 HDG 3 10d x 1-1/2 HDG 485 560 2.16 2.49 420 485 1.87 2.16<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; reduce for other load durations in accordance with the code.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

3) NAILS<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Plywood Clips – RC series<br />

Steel plywood clips. All models feature embossed dimples to<br />

provide 1/8˝ gap.<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

Provides<br />

1/8˝ gap<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>USP</strong><br />

Stock No.<br />

Steel<br />

Gauge<br />

Plywood<br />

Thickness (in)<br />

Ref. No.<br />

RC38 PSCL3/8 18 3/8<br />

RC716<br />

PSCL7/16,<br />

PSCA7/16<br />

18 7/16<br />

RC1532<br />

PSCL15/32,<br />

PSCA15/32<br />

18 15/32<br />

RC12 PSCL1/2 18 1/2<br />

RC58 PSCL5/8 18 5/8<br />

Typical RC<br />

installation<br />

RC<br />

Drywall Clip – DC1<br />

Drywall clips or “stops” help support drywall or wood paneling<br />

and reduce wood blocking on top plates, end walls, and corners.<br />

Materials: 20 gauge<br />

Finish: G90 galvanizing<br />

Installation:<br />

• Use 8d nails to install DC1, 16˝ on-centre or less.<br />

<strong>USP</strong><br />

Steel<br />

Fastener Schedule 1,2<br />

Stock No. Ref. No. Gauge Qty Type<br />

DC1 DS 20 1 8d<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) NAILS<br />

Typical DC1<br />

installation<br />

Miscellaneous<br />

3/4˝<br />

1 1 /2˝<br />

1 1 /8˝<br />

DC1<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 197<br />

<strong>USP</strong>2240-131


Nail Plates – NP series<br />

Materials: 20 gauge<br />

Finish: G90 galvanizing<br />

Installation:<br />

• Use nails appropriate for intended use. Holes are sized for<br />

8d common or 8d x 11⁄2˝ nails.<br />

• The designer shall determine appropriate load values.<br />

<strong>USP</strong><br />

Steel<br />

Dimensions (in)<br />

Number of<br />

Stock No. Ref. No. Gauge W L Nail Holes<br />

NP15 TP15 20 1-13/16 5 12<br />

NP35 TP35 20 3 5 22<br />

NP37 TP37 20 3-1/8 7 31<br />

NP39 TP39 20 3-1/8 9 40<br />

NP311 TP311 20 3-1/8 11 49<br />

NP45 TP45 20 4-1/8 5 30<br />

NP47 TP47 20 4-1/8 7 42<br />

NP49 TP49 20 4-1/8 9 54<br />

NP411 TP411 20 4-1/8 11 66<br />

NP57 TP57 20 5-3/4 7 59<br />

NP<br />

Typical Nail<br />

Plate installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Mending Plates – JNP & TPP series<br />

TPP – Prong plates with straight prongs.<br />

JNP – Prong plates with angled, hammer-in prongs.<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Installation:<br />

• These products are not intended for structural use.<br />

No load ratings are assigned. These plates are not<br />

intended for use in truss assembly.<br />

Miscellaneous<br />

<strong>USP</strong><br />

Steel Dimensions (in)<br />

Stock No. Ref. No. Gauge W L<br />

JNP24 -- -- 18 1-1/2 4<br />

JNP26 -- -- 18 1-1/2 6<br />

JNP46 -- -- 18 3-3/16 6<br />

JNP48 -- -- 18 3-3/16 8<br />

TPP14 MP14 22 13/16 3-1/2<br />

TPP24 MP24 22 1-11/16 3-1/2<br />

TPP36 MP36 22 2-3/4 5-1/4<br />

TPP58 -- -- 22 4-3/16 7-13/16<br />

JNP<br />

TPP<br />

Typical Mending Plate<br />

installation<br />

198<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Ridge Rafter – RR<br />

The RR Ridge Rafter supports rafter pitches up<br />

to 7:12 (30°). Nesting top flange for installation<br />

on 2x support beams.<br />

Materials: 18 gauge<br />

Finish: G90 galvanizing<br />

NEW<br />

Uplift<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Installation:<br />

• Use all specified fasteners. See Product<br />

Notes, page 10.<br />

• The rafter end at the ridge must be plumb cut<br />

to achieve published loads.<br />

• Optional diamond nail holes can be used to<br />

fasten RR to end of rafter before setting rafter<br />

into place.<br />

Fastener Schedule 2,3<br />

Factored Resistance 1<br />

Min<br />

Header Rafter<br />

DF-L<br />

S-P-F<br />

<strong>USP</strong><br />

Steel Rafter<br />

Download Uplift Download Uplift<br />

Stock No. Ref. No. Gauge Size Qty Type Qty Type Unit 100% 115% 100% 115%<br />

RR RR 18 2 x 6<br />

4 10d x 1-1/2 4 10d x 1-1/2<br />

Lbs 600 405 425 290<br />

kN 2.67 1.80 1.89 1.29<br />

4 LL915 4 LL915<br />

Lbs 705 345 500 245<br />

kN 3.14 1.53 2.22 1.09<br />

1) Factored resistances have been increased 15% for short-term loads such as wind and earthquake; no further increase allowed.<br />

2) Minimum nail embedment shall be 8 nail diameters (typ).<br />

Nails:<br />

red font.<br />

1"<br />

Typical RR<br />

installation<br />

1 9/16"<br />

4"<br />

3 3/8"<br />

TT Products – TT series<br />

TTA12-TZ - an angle connects two 1x wood members at<br />

90º angles.<br />

NEW<br />

RR<br />

TTA2-TZ - an angle connects two 2x wood members at<br />

90º angles.<br />

F2<br />

TTB22-TZ - a bracket connects two intersecting 2x wood<br />

members at 90º angles.<br />

TTC24-TZ - a corner tie connects 2x wood members at<br />

90º to the corner of a 2x4 post. Mirror design allows for<br />

post to be oriented in either direction.<br />

TTC42-TZ - a corner tie connects 2x wood members at<br />

90º to the corner of a 4x4 post.<br />

TTF22-TZ - a bracket connects 2x wood members to<br />

opposite sides of a 2x4 or 4x4 post.<br />

TTR-TZ - a clip connects a 2x wood member to the face<br />

of another wood member.<br />

TTA12-TZ<br />

(TTA2-TZ Similar)<br />

F1<br />

Typical<br />

TTA12-TZ<br />

installation<br />

F1<br />

Miscellaneous<br />

TTU2-TZ - a U-clip connects 2x wood members crossing<br />

at 90º.<br />

Materials: See chart<br />

Finish: G-185 galvanizing<br />

TTB22-TZ<br />

F2<br />

Typical<br />

TTB22-TZ<br />

installation<br />

continued on next page<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 199<br />

<strong>USP</strong>2240-131


TT Products – TT series continued<br />

TTC24-TZ<br />

(TTC42-TZ Similar)<br />

Typical<br />

TTC24-TZ<br />

installation<br />

Uplift<br />

TTF22-TZ<br />

Typical<br />

TTF22-TZ<br />

installation<br />

Uplift<br />

F3<br />

TTR-TZ<br />

Typical<br />

TTR-TZ<br />

installation<br />

F2<br />

F1<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

F2<br />

F1<br />

TTU2-TZ<br />

Typical<br />

TTU22-TZ<br />

installation<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• <strong>USP</strong> LumberLok LL915 (#9 x 1-3/8ʺ long) wood screws<br />

are not supplied with connectors.<br />

Miscellaneous<br />

<strong>USP</strong><br />

Stock No.<br />

TTA12-TZ<br />

TTA2-TZ<br />

TTB22-TZ<br />

TTC24-TZ<br />

TTC42-TZ<br />

TTF22-TZ<br />

TTR-TZ<br />

TTU2-TZ<br />

Fastener Schedule 1<br />

Factored Resistance 2,3,4<br />

Post Joist (Total)<br />

DF-L<br />

S-P-F<br />

Steel Post Joist<br />

Download F1 F2 F3 Uplift Download F1 F2 F3 Uplift<br />

Ref. No. Gauge Size Size Qty Type Qty Type Unit 100% 100% 100% 115% 115% 100% 100% 100% 115% 115%<br />

Lbs -- -- 335 330 -- -- -- -- -- -- 255 235 -- -- -- --<br />

RTA12 18 1x 1x 4 LL915 4 LL915<br />

kN -- -- 1.49 1.47 -- -- -- -- -- -- 1.13 1.05 -- -- -- --<br />

Lbs -- -- 315 440 -- -- -- -- -- -- 225 315 -- -- -- --<br />

RTA2Z 16 2x 2x 4 LL915 4 LL915<br />

kN -- -- 1.40 1.96 -- -- -- -- -- -- 1.00 1.40 -- -- -- --<br />

Lbs -- -- 610 425 -- -- -- -- -- -- 435 300 -- -- -- --<br />

RTB22 20 2x 2x 4 LL915 4 LL915<br />

kN -- -- 2.71 1.89 -- -- -- -- -- -- 1.94 1.33 -- -- -- --<br />

RTC24,<br />

Lbs 1125 -- -- -- -- 820 -- -- 800 -- -- -- -- 580 -- --<br />

18 2 x 4 2x 9 LL915 8 LL915<br />

RTC24Z<br />

kN 5.00 -- -- -- -- 3.65 -- -- 3.56 -- -- -- -- 2.58 -- --<br />

RTC42,<br />

Lbs 1400 -- -- -- -- 860 -- -- 995 -- -- -- -- 610 -- --<br />

18 4 x 4 2x 14 LL915 8 LL915<br />

RTC42Z<br />

kN 6.23 -- -- -- -- 3.83 -- -- 4.43 -- -- -- -- 2.71 -- --<br />

Lbs 1075 -- -- -- -- -- -- 495 765 -- -- -- -- -- -- 350<br />

RTF2Z 18 2 x 4 2x 4 LL915 8 LL915<br />

kN 4.78 -- -- -- -- -- -- 2.20 3.40 -- -- -- -- -- -- 1.56<br />

Lbs -- -- 490 545 235 -- -- -- -- 350 390 170 -- --<br />

RTR 20 2x 2x 2 LL915 4 LL915<br />

kN -- -- 2.18 2.42 1.05 -- -- -- -- 1.56 1.73 0.76 -- --<br />

Lbs -- -- 565 550 -- -- -- -- -- -- 400 390 -- -- -- --<br />

RTU2 18 2x 2x 2 LL915 4 LL915<br />

kN -- -- 2.51 2.45 -- -- -- -- -- -- 1.78 1.73 -- -- -- --<br />

1) LL915 denotes a <strong>USP</strong> LumberLok Screw, #9 x 1-3/8" long.<br />

2) Factored resistances have been increased 15% for short duration loading. No further increase is permitted.<br />

3) TTF22-TZ: Factored resistances must be equally distributed on both joists.<br />

4) TTC24-TZ and TTC42-TZ: Factored resistances listed in this table are for each joist being carried by the post.<br />

New products or updated product information are designated in red font.<br />

200<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Wall Ties – WT series<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: 22 gauge<br />

Finish: G90 galvanizing<br />

Options: WT22 is available in Stainless Steel. To order,<br />

add SS to stock number, as in WT22-SS.<br />

Dimensions (in) Fastener Schedule 1,2 <strong>USP</strong><br />

Steel<br />

1 ˝ space<br />

between<br />

brick and<br />

sheathing<br />

Stock No. Ref. No. Gauge W L Qty Type<br />

WT17HD-75 -- -- 22 1 7 3 10d<br />

WT22 BTB 22 7/8 6-1/2 1 10d<br />

1) Minimum nail embedment shall be 8 nail diameters (typ).<br />

2) NAILS<br />

Installation:<br />

• Use nails appropriate for intended use.<br />

• The opposite end must be bonded in the mortar joint of brick facade.<br />

• Check local codes for spacing requirements.<br />

• Wall tie shall be bent at nail, bonding into mortar joint.<br />

• Meets prescriptive requirements of CSA A370-04 for corrugated strip ties.<br />

Typical WT<br />

installation<br />

W<br />

L<br />

Angles – ML series<br />

WT<br />

ML angles are multi-purpose angles that install easily with<br />

<strong>USP</strong>’s WS15 wood screws. The staggered fastener pattern<br />

allows for back-to-back installations.<br />

Materials: 12 gau ge<br />

Finish: G-185 galvanizing<br />

NEW<br />

Load<br />

Direction<br />

Installation:<br />

• Use all specified fasteners. See Product Notes, page 10.<br />

• <strong>USP</strong> WS15 (1/4″ x 1-1/2″) are not supplied with ML<br />

angles.<br />

<strong>USP</strong><br />

Stock No.<br />

ML24-TZ<br />

ML26-TZ<br />

Dimensions (in) Fastener Schedule 2,3 Factored Resistance 1<br />

Header Joist DF-L (Lbs) S-P-F (Lbs)<br />

Steel<br />

Ref. No. Gauge W H Qty Type Qty Type Unit 100% 115% 100% 115%<br />

ML24,<br />

Lbs 1100 1265 780 900<br />

12 2 4 3 WS15 3 WS15<br />

ML24Z<br />

kN 4.89 5.63 3.47 4.00<br />

ML26,<br />

Lbs 1890 2175 1340 1545<br />

12 2 6 4 WS15 4 WS15<br />

ML26Z<br />

kN 8.41 9.68 5.96 6.87<br />

1) Factored resistances have been increased 15% for short duration loading; no further increase allowed.<br />

2) <strong>USP</strong>'s WS15 Wood Screws are 1/4" diameter x 1-1/2" long and are not included with angles.<br />

3) For exterior applications use WS15-GC screws with the Gold Coat finish<br />

New products or updated product information are designated in red font.<br />

Typical ML26-TZ<br />

installation<br />

(ML24-TZ similar)<br />

W<br />

W<br />

H<br />

Miscellaneous<br />

ML26-TZ<br />

(ML24-TZ similar)<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 201<br />

<strong>USP</strong>2240-131


Closet Rods – CRZ & CRW series<br />

These adjustable Closet Rods are available in various lengths which<br />

attach easily to wall studs or shelf support strapping (see diagram).<br />

.<br />

Materials: 20 gauge cold rolled steel<br />

Finish: CRZP – Zinc coated;<br />

CRWP – Electro-static powdered coated (white)<br />

<strong>USP</strong><br />

Stock No.<br />

Ref. No.<br />

CRWP1830 -- -- 20 <br />

CRWP3048 -- -- 20 <br />

CRWP4872 -- -- 20 <br />

CRWP7296 -- -- 20 <br />

CRWP96120 -- -- 20 <br />

<strong>USP</strong><br />

Stock No.<br />

Steel Adjustable<br />

Gauge Size (in)<br />

Steel<br />

Gauge<br />

Adjustable<br />

Size (in)<br />

Ref. No.<br />

CRZP1830 -- -- 20 <br />

CRZP3048 -- -- 20 <br />

CRZP4872 -- -- 20 <br />

CRZP7296 -- -- 20 <br />

CRZP96120 -- -- 20 <br />

Typical CRZ/CRW<br />

installation<br />

CRZ/CRW<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Fluted Closet Rods – CRZFP & CRWFP series<br />

These adjustable Fluted Closet Rods are a two-piece design which consists of<br />

separate end brackets to be installed prior to inserting the closet rods into place.<br />

Materials: 20 gauge cold rolled steel<br />

Finish: CRZFP – Zinc coated;<br />

CRWFP – Electro-static powdered coated (white)<br />

Miscellaneous<br />

<strong>USP</strong><br />

Stock No.<br />

Steel<br />

Gauge<br />

Adjustable<br />

Size (in)<br />

Ref. No.<br />

CRWFP1830 -- -- 20 <br />

CRWFP3048 -- -- 20 <br />

CRWFP4872 -- -- 20 <br />

CRWFP7296 -- -- 20 <br />

CRWFP96120 -- -- 20 <br />

CRZF/CRWF<br />

<strong>USP</strong><br />

Stock No.<br />

Steel<br />

Gauge<br />

Adjustable<br />

Size (in)<br />

Ref. No.<br />

CRZFP1830 -- -- 20 <br />

CRZFP3048 -- -- 20 <br />

CRZFP4872 -- -- 20 <br />

CRZFP7296 -- -- 20 <br />

CRZFP96120 -- -- 20 <br />

202<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Shelf Brackets – SB series<br />

These Shelf Brackets combine shelving capabilities and closet rod support in a<br />

one-piece design.<br />

Materials: 13 gauge cold rolled steel<br />

Finish: SBZ – Zinc plated;<br />

SBW – Electro-static powdered coated (white)<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>USP</strong><br />

Steel<br />

Dimensions (in)<br />

Stock No. Ref. No. Gauge W L<br />

SBZ -- -- 13 11 9-1/2<br />

SBW -- -- 13 11 9-1/2<br />

SBZ<br />

Insulation Supports – IS series<br />

Insulation supports secure batt-type insulation in place between joists. Chisel-cut ends<br />

dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces.<br />

Materials: 13 gauge carbon steel wire<br />

Finish: None<br />

Installation:<br />

• Use IS16 for joist spaced 16˝ O.C. and IS24 for<br />

24˝ O.C. spacing.<br />

• Position insulation batt in place between joists.<br />

Hold IS unit at the centre and push into place.<br />

• Wear gloves and safety glasses during installation.<br />

Simply push<br />

into place<br />

Miscellaneous<br />

Typical IS<br />

installation<br />

<strong>USP</strong><br />

Steel Joist<br />

Dimensions (in)<br />

Stock No. Ref. No. Gauge Spacing Overall Length<br />

IS16 -- -- 13 15-1/2<br />

IS24 -- -- 13 23-1/2<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 203<br />

<strong>USP</strong>2240-131


Plastic Post Caps – PCP series<br />

These seamless caps keep water off post tops, protecting wood from moisture damage. The PCP’s<br />

plastic construction is corrosion-proof and paintable. Not available in rough or full lumber sizes.<br />

Materials: Hi-impact plastic<br />

Finish: Gray<br />

Installation:<br />

• Fasten cap to post top with<br />

(1) 8d HDG or 10d HDG nail.<br />

• See Product Notes, page 10.<br />

W<br />

W<br />

Post /<br />

Column Size 1<br />

<strong>USP</strong><br />

Stock No.<br />

Dimension (in)<br />

Ref. No. W Color<br />

4 x 4 PCP44 DPPC4BK 3-5/8 Gray<br />

6 x 6 PCP66 DPPC6BK 5-5/8 Gray<br />

1) Not available in rough or full lumber sizes.<br />

Corner Tie – KSCT68<br />

The Corner Tie secures three-way wood-to-wood<br />

connections. Handy for building workbenches,<br />

utility tables, or shelving using 2x4 lumber.<br />

6˝<br />

PCP66<br />

Typical PCP44<br />

installation<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: 14 gauge<br />

Finish: G90 galvanizing<br />

2˝<br />

Installation:<br />

• Use (12) #10 panhead screws to fasten the<br />

KSCT68 to wood framing.<br />

8˝<br />

KSCT68<br />

Typical KSCT68 installation<br />

Miscellaneous<br />

204<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Power Nail <strong>Hangers</strong> – JN, JN(E), MRT7 & MTHF series<br />

Designed for assembly line installation, these<br />

hangers feature a generous flange area to<br />

accommodate power nailer maneuvering.<br />

Engineered for economical installation and<br />

maximum load values.<br />

NEW<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Materials: See chart<br />

Finish: G90 galvanizing<br />

Codes: Factored resistances are<br />

derived from data submitted<br />

to various North American<br />

building code evaluators and<br />

are in accordance<br />

with CSA O86-09.<br />

Installation:<br />

• Install all fasteners with a pneumatic nailer.<br />

See Product Notes, page 10.<br />

• Nailing zones are distinguished by embossed<br />

pattern.<br />

• Install fasteners with care not to overdrive<br />

fastener causing indentation of connector.<br />

• Fastener quantities shall be installed<br />

symmetrically on both sides of connector.<br />

• Installer should reduce risk of injury from<br />

rebounding fasteners by using personal eye<br />

protection during fastener installation.<br />

• Minimum center to center fastener spacing<br />

is 1”.<br />

Typical MRT7<br />

installation<br />

W<br />

H<br />

MRT7<br />

Typical MTHF<br />

installation<br />

W<br />

D<br />

A<br />

MTHF<br />

H<br />

Nailing<br />

Zones<br />

Typical JNE<br />

installation<br />

W<br />

A<br />

D<br />

JN28E<br />

(JN26E &<br />

JN210E Similar)<br />

H<br />

<strong>USP</strong><br />

Stock No.<br />

Dimensions (in) Fastener Schedule 1,2,3<br />

Factored Resistance<br />

Header<br />

Joist<br />

DF-L<br />

S-P-F<br />

Download F1 4 F2 4 Uplift 4 Download F1 4 F2 4 Uplift 4<br />

Steel<br />

Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN Lbs kN<br />

Ref. No. Gauge W H D A Qty Type Qty Type 100% 100% 115% 115% 115% 115% 115% 115% 100% 100% 115% 115% 115% 115% 115% 115%<br />

3 "P" or "T" nails 3 "P" or "T" nails -- -- -- -- 85 0.38 85 0.38 360 1.60 -- -- -- -- 65 0.29 65 0.29 335 1.49<br />

MRT7 <br />

<br />

-- -- -- --<br />

4 "P" or "T" nails 4 "P" or "T" nails -- -- -- -- 115 0.51 115 0.51 480 2.14 -- -- -- -- 85 0.38 85 0.38 445 1.98<br />

5 "P" or "T" nails 5 "P" or "T" nails -- -- -- -- 145 0.65 145 0.65 600 2.67 -- -- -- -- 105 0.47 105 0.47 555 2.47<br />

MTHF25925 MMLUI39 20 2<br />

MTHF25112 MMLUI311 20 <br />

JN26E MMLU26 20 4-13/16<br />

<br />

2 <br />

2 <br />

6 "P" or "T" nails 6 "P" or "T" nails -- -- -- -- 175 0.78 175 0.78 720 3.20 -- -- -- -- 125 0.56 125 0.56 665 2.96<br />

10 "P" or "T" nails 4 "P" or "T" nails 1460 6.49 -- -- -- -- -- -- -- -- 630 2.80 1250 5.56 -- -- -- -- -- -- -- -- 540 2.40<br />

16 "P" or "T" nails 4 "P" or "T" nails 2215 9.85 -- -- -- -- -- -- -- -- 630 2.80 1900 8.45 -- -- -- -- -- -- -- -- 540 2.40<br />

10 "P" or "T" nails 4 "P" or "T" nails 1460 6.49 -- -- -- -- -- -- -- -- 630 2.80 1250 5.56 -- -- -- -- -- -- -- -- 540 2.40<br />

16 "P" or "T" nails 4 "P" or "T" nails 2215 9.85 -- -- -- -- -- -- -- -- 630 2.80 1900 8.45 -- -- -- -- -- -- -- -- 540 2.40<br />

10 "P" or "T" nails 4 "P" or "T" nails 1460 6.49 -- -- -- -- -- -- -- -- 630 2.80 1250 5.56 -- -- -- -- -- -- -- -- 540 2.40<br />

16 "P" or "T" nails 4 "P" or "T" nails 2215 9.85 -- -- -- -- -- -- -- -- 630 2.80 1900 8.45 -- -- -- -- -- -- -- -- 540 2.40<br />

10 "P" or "T" nails 4 "P" or "T" nails 1460 6.49 -- -- -- -- -- -- -- -- 630 2.80 1250 5.56 -- -- -- -- -- -- -- -- 540 2.40<br />

JN28E 20 6-11/16 2<br />

<br />

16 "P" or "T" nails 4 "P" or "T" nails 2215 9.85 -- -- -- -- -- -- -- -- 630 2.80 1900 8.45 -- -- -- -- -- -- -- -- 540 2.40<br />

20 "P" or "T" nails 4 "P" or "T" nails 2300 10.23 -- -- -- -- -- -- -- -- 630 2.80 1970 8.76 -- -- -- -- -- -- -- -- 540 2.40<br />

JN210E<br />

MMLU210,<br />

MMLU211<br />

20 2<br />

JN26-2 MMLU26-2 2<br />

JN28-2 <br />

<br />

<br />

2 <br />

10 "P" or "T" nails 4 "P" or "T" nails 1460 6.49 -- -- -- -- -- -- -- -- 630 2.80 1250 5.56 -- -- -- -- -- -- -- -- 540 2.40<br />

16 "P" or "T" nails 4 "P" or "T" nails 2215 9.85 -- -- -- -- -- -- -- -- 630 2.80 1900 8.45 -- -- -- -- -- -- -- -- 540 2.40<br />

20 "P" or "T" nails 4 "P" or "T" nails 2300 10.23 -- -- -- -- -- -- -- -- 630 2.80 1970 8.76 -- -- -- -- -- -- -- -- 540 2.40<br />

10 "P" or "T" nails 6 "P" or "T" nails 1370 6.09 -- -- -- -- -- -- -- -- 1540 6.85 1175 5.23 -- -- -- -- -- -- -- -- 1320 5.87<br />

16 "P" or "T" nails 6 "P" or "T" nails 3035 13.50 -- -- -- -- -- -- -- -- 1540 6.85 2600 11.57 -- -- -- -- -- -- -- -- 1320 5.87<br />

10 "P" or "T" nails 6 "P" or "T" nails 1370 6.09 -- -- -- -- -- -- -- -- 1540 6.85 1175 5.23 -- -- -- -- -- -- -- -- 1320 5.87<br />

16 "P" or "T" nails 6 "P" or "T" nails 3035 13.50 -- -- -- -- -- -- -- -- 1540 6.85 2600 11.57 -- -- -- -- -- -- -- -- 1320 5.87<br />

24 "P" or "T" nails 6 "P" or "T" nails 3715 16.53 -- -- -- -- -- -- -- -- 1540 6.85 3185 14.17 -- -- -- -- -- -- -- -- 1320 5.87<br />

<br />

<br />

2) Fasteners shall be pneumatically driven in such a way as firmly seats the nail head against the hanger steel, without embedding the nail head completely through the plane of the metal surface, or otherwise punching through.<br />

<br />

<br />

<br />

New products or updated product information are designated in red font.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 205<br />

<strong>USP</strong>2240-131<br />

Manuf. Housing


Hardy Frame® HFX-Series Panels and Brace Frames<br />

Lateral Systems<br />

Hardy Frame® HFX-Series Panels and Brace Frames<br />

combine the most desirable properties for a shear wall:<br />

strength, stiffness and ductility. This revolutionary system<br />

has been tested and evaluated under the ICC-Evaluation<br />

Service AC322 Acceptance Criteria and has been proven<br />

to provide the highest allowable shear loads in the<br />

industry combined with abundant ductility for a seismic<br />

“R” value of 6.5. Along with its superior engineering<br />

properties the HFX-Series is easier than ever to install,<br />

is code listed for varied installations that include support on a floor system and vertical<br />

stacking conditions. Anchorage solutions include standard grade or high strength<br />

grade for maximum values<br />

Panel on concrete<br />

with 2x filler<br />

Panel on concrete<br />

at portal<br />

NEW<br />

® ®<br />

Panel at raised floor<br />

head-out<br />

Hardy Frame® HFX-Series Panels are available in widths of 9, 12, 15, 18, 21 and<br />

24-inches and are typically manufactured in heights that correspond to a standard<br />

portal (78 inches) and standard wood stud lengths. When installed on concrete<br />

simply secure to the foundation with a Hardy Frame® Template Kit that includes<br />

two 1-1/8 inch diameter hold down anchors (grade is specified by the Design<br />

Professional). The top channel connects to a collector above with 1/4-inch diameter<br />

<strong>USP</strong> “WS-Series” screws through pre-punched holes.<br />

Vertical ® Stacking<br />

Brace Frames<br />

Vertical Stacking<br />

Panels<br />

®<br />

Brace Frame on Brace Frame at raised<br />

concrete with 2x filler floor head-out<br />

Hardy Frame® HFX-Series Brace Frames are 32 or 44 inches wide and<br />

heights correspond to standard wood stud lengths. Connections to the<br />

foundation require two 7/8 inch diameter hold down anchors (grade per<br />

the Design Professional) that are included in Hardy Frame® Template<br />

Kits. The connection to the collector above is made with 1/4-inch diameter<br />

<strong>USP</strong> “WS-Series” screws through pre-punched holes. Field studs are<br />

provided in Brace Frames for easy attachment of surface finishes with<br />

self-tapping screws.<br />

®<br />

HARDY FRAME PANEL BOTTOMOM<br />

ON MULTI STORY<br />

Panel template kit<br />

Brace Frame Kit<br />

at Interior Footing<br />

CUSTOMER SERVICE<br />

• Hardy Frame technical support is<br />

focused on pre-manufactured shear<br />

walls as our core business. Because<br />

of that focus we offer the most comprehensive<br />

service and we provide<br />

the best support for shear wall solutions<br />

in the industry.<br />

• To the Design Professional we provide<br />

prompt, accurate technical support<br />

and full design solutions backed<br />

by extensive testing and research<br />

that has an Evaluation Service<br />

Report (ESR) listing. From providing<br />

allowable design loads to addressing<br />

job specific repairs you can always<br />

count on our solutions.<br />

• To the Building Official, our Code<br />

Reports support the plan check<br />

process and our Typical Installation<br />

Details along with Installation<br />

Instruction labeling takes the guesswork<br />

out of field inspection.<br />

• To the installer, our framing background<br />

and construction experience<br />

provides us with a contractors understanding<br />

of job specific installation<br />

requirements. Quick responses are a<br />

must and project delays are avoided<br />

at all costs. Help is available by telephone,<br />

website or one of our many<br />

representatives.<br />

• To all parties, in addition to literature,<br />

details, internet and telephone<br />

support our company provides jobsite<br />

visits, seminars and personal training<br />

sessions. Inquiries are welcome and<br />

we will be available when you need<br />

our support.<br />

1732 Palma Drive,<br />

Suite 200,<br />

Ventura, CA 93003<br />

(800) 754-3030<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

206<br />

1-800-754-3030 • www.hardyframe.com


Hardy Frames® Special Moment Frame (SMRF)<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Hardy Frames introduced the first standardized,<br />

pre-manufactured Moment<br />

Frame in 2006. Since then we have produced<br />

thousands of Moment Frames that<br />

have been successfully installed. These<br />

Moment Frames have maximum structural<br />

capacities combined with the open<br />

architectural aesthetics that designers<br />

and architects need today.<br />

Hardy Frame Moment Frames are<br />

Special Moment Resisting Frames<br />

(SMRF) that use the pre-qualified<br />

SidePlate moment connection. Typically,<br />

our Moment Frames are delivered to the<br />

jobsite in one-piece, completely fabricated<br />

and ready to be installed with no<br />

assembly, no field welding and no special<br />

inspection required.<br />

On production framing jobs the Hardy<br />

Frame Moment Frame can’t be beat. We<br />

have delivered truckload quantities of up<br />

to 30 Moment Frames that were installed<br />

in a single day. That is an accomplishment<br />

that can not be matched by conventional<br />

moment frames.<br />

NEW<br />

Lateral Systems<br />

Custom Sizes and Custom<br />

Calculations<br />

We offer over 300 standard dimension<br />

Moment Frames, but we don’t stop there.<br />

We also offer calculations and solutions<br />

for sizes that are beyond the scope of our<br />

standard listing. We commonly provide<br />

solutions for two-story and multi-story<br />

frames as well as for fixed based connections.<br />

Please note that standard dimensions<br />

can be adjusted without being treated<br />

as a “Custom Order”. Our typical lead<br />

time of 3-4 weeks does not increase and<br />

neither does your cost.<br />

Moment Frame<br />

Template Kits<br />

Template Kits are included with the purchase<br />

of the Hardy Frame Moment<br />

Frame and are a stock item that can be<br />

shipped within one business day. The<br />

Kit includes all embed anchors, nuts,<br />

washers and Templates so the concrete<br />

pour can proceed prior to the Moment<br />

Frame delivery. Correctly locating the<br />

anchors is easy with a slot provided in<br />

the Template to measure the “Win”,<br />

(inside steel-to-steel) dimension.<br />

• Inquiries are welcome and we will be<br />

available when you need our support.<br />

1732 Palma Drive,<br />

Suite 200,<br />

Ventura, CA 93003<br />

(800) 754-3030<br />

1-800-754-3030 • www.hardyframe.com 207<br />

<strong>USP</strong>2240-131


Hardy Frames® Z4 Continuous Rod Tie-Down Systems<br />

Lateral Systems<br />

QUICK CONNECT SYSTEMS FOR RESISTING LATERAL LOAD AND WIND UPLIFT<br />

QUICK CONNECT ASSEMBLY<br />

NEW<br />

Z4 Continuous Rod Tie-Down Systems utilize Z4 “Cinch Nuts”<br />

to compensate for wood shrinkage and building settlement<br />

that cause connections to loosen over time. The Cinch Nut<br />

uses a self-ratcheting action that permits threaded rods to<br />

move, or “travel” perpetually in one direction only through the<br />

device. Available for installation with threaded rods that are<br />

5/8 inch through 1-1/2 inch diameter in 1/8 inch increments,<br />

the Z4 Cinch Nut has been code evaluated and published in<br />

ESR-2190.<br />

Quick Connect<br />

System for Lateral<br />

Loads<br />

HARDY FRAME® Z4 CONTINUOUS<br />

ROOF RAFTERS<br />

ROOF RAFTERS<br />

To resist tension loads due<br />

to overturning moments in<br />

multi-story buildings the Z4<br />

Cinch Nut is installed over a<br />

Bearing Plate at each level<br />

in a fast and easy “Quick<br />

Connect” application. At the<br />

upper-most level a Cinch<br />

Nut is installed over a<br />

Bearing Plate above the top<br />

plates. At walls below that<br />

bear on wood floor systems<br />

the Cinch Nut and Bearing<br />

Plate is installed over the<br />

bottom plate. Tension loads<br />

are gathered at each level<br />

and transferred into the<br />

foundation through a<br />

continuous system of Cinch<br />

Nuts, Bearing Plates,<br />

threaded rods and coupling<br />

nuts, all available from<br />

Hardy Frame – Z4.<br />

Quick Connect<br />

System for Wind<br />

Uplift<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Customer Service<br />

• Hardy Frame-Z4 offers comprehensive technical support,<br />

design of tie-down systems to meet engineered loads and<br />

delivers products packaged and labeled for easy identification<br />

in the field.<br />

• For the Design Professional Z4 provides pre-engineered<br />

standard runs as well as individual component capacities to<br />

design custom runs. We also offer turn-key, sealed designs<br />

when engineered loads are provided to us.<br />

• Building Officials will be confident approving our systems<br />

because they assemble with code evaluated components that<br />

have an ESR listing.<br />

For resisting roof uplift loads<br />

resulting from wind the Z4<br />

Cinch Nut is installed over a<br />

Bearing Plate above the top<br />

plates with roof framing<br />

above to create a tie-down<br />

system. Uplift forces are<br />

transferred into a continuous<br />

system of threaded<br />

rods and coupling nuts that<br />

form a load path to the<br />

foundation.<br />

• For the installer, our products will arrive on time and be<br />

packaged systematically for easy identification of parts and<br />

sequence of assembly. We offer typical installation details,<br />

immediate telephone support and personal training is available<br />

from a sales or customer service representative.<br />

208<br />

For more information on the Z4 product line, please contact us at 951-245-9525 • www.hardyframe.com<br />

1-951-245-9525 • www.hardyframe.com


Hardy Frame® Z4 CT and T2<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

PAIRED AND SANDWICHED CONNECTIONS FOR TENSION AND COMPRESSION<br />

LOAD TRANSFER<br />

Paired CT Wall Tie<br />

T2 installation similar<br />

NEW<br />

Z4 Continuity Tie<br />

The Z4 “CT” is a steel tube with steel<br />

end plates welded to both ends designed<br />

to transfer tension and compression<br />

forces from one beam to another<br />

(Continuity Tie application) or from a<br />

beam to a perpendicular wall (Wall Tie<br />

application). Connections are made by<br />

bolting the tube to a wood member and<br />

attaching to a threaded rod for<br />

transferring forces.<br />

Accurate Placement and<br />

Installation<br />

Lateral Systems<br />

Paired T2 Continuity Tie<br />

Step 1: Use the two 3/16” holes provided<br />

to nail CT or T2 at desired location on<br />

wood member<br />

Step 2: Use the CT or T2 as a template<br />

to accurately drill holes for bolting<br />

Step 3: Make bolted connection to the<br />

wood member per plans and<br />

specifications<br />

Step 4: Make threaded rod connection<br />

per plans and specifications.<br />

Z4 Tension Tie<br />

Sandwiched T2<br />

As Concentric<br />

Hold-Down<br />

Paired T2<br />

For Concentric,<br />

High Capacity<br />

Hold-Down<br />

The Z4 “T2” is a steel tube with a steel<br />

end plate welded to one end designed to<br />

transfer tension forces as a concentric<br />

hold-down device. Sandwiched<br />

Installations are made by through bolting<br />

two wood members with a T2 between<br />

and “Paired Installations” through bolt<br />

two T2 connectors with a wood member<br />

between. For both installation methods<br />

the tube is then attached to a threaded<br />

rod to transfer the tension loads.<br />

For more information on the Z4 product line, please contact us at 951-245-9525 • www.hardyframe.com<br />

1-951-245-9525 • www.hardyframe.com 209<br />

<strong>USP</strong>2240-131


Specialty Options & General Notes<br />

Specialty Options<br />

<strong>USP</strong><br />

Series<br />

Width<br />

Skewed (Maximum)<br />

Sloped Seat (Maximum)<br />

Sloped / Skewed<br />

Sloped Top Flange (Maximum)<br />

BPH all 50º 45º 45º <br />

GHF all 50º 45º <br />

67-1/2º<br />

HD 1<br />

45º<br />

50º<br />

67-1/2º<br />

HDO 45º<br />

50º<br />

Top Flange Offset<br />

Saddle Hanger<br />

Ridge Hanger (Maximum)<br />

Inverted Flange<br />

<br />

width ><br />

<br />

width ><br />

<br />

width ><br />

Uplift<br />

Weldability<br />

<strong>USP</strong> Series<br />

Catalog Page Reference<br />

124-125,<br />

128-129,<br />

132-136,<br />

138-142<br />

146<br />

90-96,<br />

<br />

118,<br />

122-123<br />

97,<br />

<br />

99-101<br />

HGU all 45º<br />

<br />

145<br />

width ><br />

HJC all 60º 173<br />

126,<br />

HLBH all 50º 45º 45º 45º 132-136,<br />

138-142<br />

<br />

89,<br />

HUS<br />

all<br />

width ><br />

91-95,<br />

<br />

119, 123,<br />

167<br />

HWUH all 45º 45º 106-107<br />

KB all <br />

97,<br />

100-101<br />

KEG all 45º 45º 147<br />

KGB all 148<br />

KGLS all 50º 45º 30º 150<br />

KGLST all 150<br />

KGLT all 50º 45º 45º 149<br />

KHGB all 148<br />

KHGLS all 50º 45º 30º 150<br />

KHGLST all 150<br />

KHGLT all 50º 45º 45º 149<br />

KHHB all 148<br />

KHW all 84º 45º 35º 45º <br />

98,<br />

100-101<br />

KLB all 97, 99<br />

KLEG all 45º 45º 147<br />

KMEG all 45º 45º 147<br />

LGU all 45º<br />

<br />

145<br />

width ><br />

LSSH all 45º 45º 103, 144<br />

MGU all 45º<br />

<br />

145<br />

width ><br />

MPH 1 60º 45º <br />

108,<br />

126-141<br />

MSHL/R all 45º 170<br />

PHM 1 all 84º 45º 35º 45º <br />

126-131,<br />

133-141<br />

PHXU 1 all 60º 45º 35º <br />

126-129,<br />

132-136,<br />

138-142<br />

SKH all 45º 104-105<br />

SKHH all 45º 104-105<br />

SUH<br />

67-1/2º<br />

88,<br />

45º <br />

<br />

50º<br />

91-96<br />

SW 1 all 84º 45º 35º 45º 98-100<br />

SWH 1 all 84º 45º 35º 45º 98-101<br />

THD all<br />

45º 45º <br />

<br />

<br />

<br />

<br />

width ><br />

<br />

120, 123,<br />

165<br />

The information listed only applies<br />

to hangers manufactured by<br />

<strong>USP</strong> Structural <strong>Connectors</strong>® and<br />

installed according to the<br />

instructions listed in this catalogue.<br />

Some of the options listed may not<br />

have been evaluated on a single<br />

hanger. The designer must always<br />

evaluate each connection, including<br />

the joist and header capacities,<br />

before specifying a specialty<br />

connector. <strong>USP</strong> sloped hangers are<br />

manufactured with the plumb cut of<br />

the joist already calculated. If a<br />

hanger with a different height is<br />

needed, it must be specified at the<br />

time of ordering.<br />

Materials: Steel gauge may vary<br />

from that specified depending on<br />

the specialty option and<br />

manufacturing process used. Some<br />

formed hangers may be welded<br />

when modifying the hanger. Hanger<br />

configurations, fastener schedules,<br />

and height may vary from the tables<br />

depending on the joist size, skew,<br />

and slope.<br />

Finish: See specific hanger option<br />

tables. Welded hangers are painted<br />

with <strong>USP</strong> gray primer. Custom<br />

hangers available in Hot-dip<br />

galvanized, use HDG after product<br />

number.<br />

Factored Resistance: For multiple<br />

options for the same connector, use<br />

the most conservative reduction to<br />

give the lowest design load.<br />

Installation:<br />

• Fill all nail holes with fasteners<br />

specified in the tables.<br />

• Fastener quantities may increase<br />

from the amount listed in the tables<br />

depending on hanger option.<br />

• NA16D-RS and NA20D nails are<br />

supplied with hangers.<br />

• For type A skewed hangers, the<br />

end of joist must be bevel cut; for<br />

type B skewed hangers, the end of<br />

joist must be butt-cut.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

THDH all 45º 45º <br />

THF<br />

67-1/2º<br />

50º<br />

45º <br />

<br />

width ><br />

<br />

120,123,<br />

166-167<br />

118,<br />

121-122<br />

<br />

<br />

210<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Face Mount Hanger Specialty Details<br />

See the Specialty Options Chart for each hanger series for load<br />

reductions and hanger maximum range of skew, slope, etc.<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

Skewed Hanger:<br />

• Consider SKH or SKHH hangers for 45° skews.<br />

• Joist nails may be located on obtuse side to ensure<br />

proper nailing.<br />

• Specify skew angle, type (A or B), and direction when<br />

ordering.<br />

Sloped Seat Hanger:<br />

• Consider LSSH series for sloped applications.<br />

• Additional nail holes may be added to joist flanges.<br />

• Specify slope angle and direction when ordering.<br />

Sloped/Skewed Hanger:<br />

• See nailing notes for both skewed and sloped hangers.<br />

• Specify skew and slope angles as well as skew/slope<br />

directions and skew type (A or B) when ordering.<br />

Inverted Flange Hanger:<br />

• For skewed-only hangers, the flange on the cut side can be<br />

inverted at 100% of the table load. Consult <strong>USP</strong> for skew<br />

limitations.<br />

• When nailing into the carrying member’s end grain, the<br />

factored resistance is 0.65 of the table load.<br />

• <strong>Hangers</strong> with one flange inverted achieve 100% of listed<br />

table load.<br />

• Specify right or left flange when inverting only one flange.<br />

Plumb<br />

height<br />

Specify<br />

angle<br />

Open Top Flange Hanger Specialty Details<br />

Typical SUH hanger<br />

skewed, right shown,<br />

Type A (bevel cut required)<br />

Specify<br />

angle<br />

Joist<br />

height<br />

Typical HD hanger<br />

sloped seat,<br />

down shown<br />

Slope<br />

angle<br />

Specify<br />

angle<br />

Typical SUH formed<br />

hanger skewed, right<br />

shown, Type B<br />

Skew<br />

angle<br />

Typical HD hanger<br />

sloped down,<br />

skewed left shown<br />

Typical HD hanger<br />

inverted flange<br />

Specialty Options<br />

See Specialty Options Chart for each hanger series for load<br />

reductions and hanger maximum range of skew, slope, etc.<br />

Skewed Hanger:<br />

• Joist nails may be located on obtuse side to ensure<br />

proper nailing.<br />

• Specify skew angle, type (A or B), and direction<br />

when ordering.<br />

Sloped Seat Hanger:<br />

• Additional nail holes may be added to joist flanges.<br />

• Specify slope angle, direction, and joist height when<br />

ordering.<br />

Sloped/Skewed Hanger:<br />

• See nailing notes for both skewed and sloped hangers.<br />

• Specify skew and slope angles as well as skew/slope<br />

directions, and skew type (A or B) when ordering.<br />

• Similar to face mount skewed/sloped hanger, refer to<br />

illustration above: Typical HD hanger sloped down,<br />

skewed left shown.<br />

• Specify if hanger is to be high side flush, low side flush,<br />

or centre flush.<br />

Sloped/Skewed/Sloped Top Flange Hanger:<br />

• See nailing notes for both skewed and sloped hangers.<br />

• Specify skew, slope, and top flange slope angles as<br />

well as skew/slope and top flange slope directions<br />

when ordering.<br />

• Skewed/sloped/top flange sloped hangers can be<br />

made galvanized or painted.<br />

Specify<br />

angle<br />

Typical BPH hanger<br />

skewed, left shown<br />

Type A (bevel cut required)<br />

Plumb<br />

height<br />

Joist skew<br />

right shown<br />

Joist<br />

height<br />

Slope<br />

angle<br />

Specify<br />

angle<br />

Typical BPH hanger<br />

sloped seat, down shown<br />

Specify<br />

angle<br />

Specify<br />

angle<br />

Typical BPH hanger<br />

skewed, right shown<br />

Type B<br />

Skew angle<br />

Specify angle<br />

Slope<br />

angle<br />

Typical BPH hanger<br />

sloped down, skewed right,<br />

low side flush shown<br />

high side flush<br />

center flush<br />

low side flush<br />

Typical BPH hanger<br />

skewed right, sloped<br />

down, top flange sloped<br />

Typical HLBH hanger<br />

sloped top flange right<br />

shown<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 211<br />

<strong>USP</strong>2240-131


Solid Top Flange Hanger Specialty Details<br />

Specialty Options<br />

See Specialty Options Chart for each hanger series for load<br />

reductions and hanger maximum range of skew, slope, etc.<br />

Skewed Hanger:<br />

• Joist nails may be located on obtuse side to ensure proper<br />

nailing.<br />

• Specify skew angle, type (A or B), and direction when ordering.<br />

Sloped Seat Hanger:<br />

• Additional nail holes may be added to joist flanges.<br />

• Specify slope angle, direction, and joist height when ordering.<br />

Sloped/Skewed Hanger:<br />

• See nailing notes for both skewed and sloped hangers.<br />

• Specify skew and slope angles as well as skew/slope<br />

directions, and skew type (A or B) when ordering.<br />

• Specify if hanger is to be high side flush, low side flush, or<br />

centre flush.<br />

Sloped Top Flange Hanger:<br />

• Additional nail holes may be added to top angle.<br />

• Specify top flange slope and direction when ordering.<br />

• Specify if hanger is to be high side flush, low side<br />

flush, or centre flush.<br />

Ridge Hanger:<br />

• Specify flush top of beam at centre, right side, or<br />

left side.<br />

• Specify angle of slope when ordering.<br />

Top Flange Offset Hanger:<br />

• Specify offset, left (L) or right (R), when ordering.<br />

Saddle Hanger:<br />

• Specify saddle width, “SA” when ordering. Allow<br />

clearance for saddled member.<br />

Specify angle<br />

Typical PHXU hanger<br />

skewed, left shown Type A<br />

(bevel cut required)<br />

Specify angle<br />

high side flush<br />

center flush<br />

low side flush<br />

Typical HLBH hanger<br />

sloped top flange,<br />

right shown<br />

SA<br />

W 2<br />

Specify angle<br />

Typical PHXU hanger<br />

skewed, left shown<br />

Type B<br />

Specify<br />

angle<br />

Typical HLBH hanger<br />

ridge, top<br />

flange slope<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

H 2<br />

H 1<br />

W 1<br />

Typical PHXU hanger<br />

saddle option<br />

Typical HLBH hanger top<br />

flange offset, right shown<br />

Specify<br />

angle<br />

Plumb<br />

height<br />

Specify<br />

angle<br />

Skew<br />

angle<br />

Slope<br />

angle<br />

Typical HLBH hanger<br />

sloped down, skewed right,<br />

low side flush shown<br />

Joist<br />

Height<br />

Typical HLBH hanger<br />

sloped seat, down shown<br />

Joist skew<br />

right shown<br />

Slope<br />

angle<br />

Typical HLBH hanger<br />

skewed right, sloped<br />

down, top flange sloped<br />

212<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com


Welded Top Flange<br />

• Weld sizes and lengths shown on chart.<br />

Top Angle Weld Length chart<br />

Typical<br />

see<br />

chart<br />

Continuous<br />

weld along<br />

back of top<br />

flange<br />

<strong>USP</strong><br />

Welded Hanger Series<br />

Weld<br />

Length<br />

Top Angle<br />

Steel Gauge<br />

Weld<br />

Size<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

SW 10 gauge or lighter <br />

BPH, PHM, SWH 7 gauge <br />

KLB, KHW, PHXU 3 gauge <br />

KB, KGB, KHGB, KHHB,<br />

KGLS, KGLST, KGLT, <br />

KHGLS, KHGLST<br />

HLBH, KHGLT<br />

<br />

Weld shall be distributed evenly.<br />

Part Number System<br />

Part Numbers assigned to TFL, THO, and THF<br />

I-Joist hangers reveal the I-Joist sizes to be<br />

used with the specific hanger. This guide will<br />

teach you how to recognize I-Joist dimensions<br />

in the part numbers.<br />

Typical Top Angle<br />

welded installation<br />

Typical Top Flange<br />

welded installation<br />

THO35925-2<br />

Specialty Options<br />

1 st , 3 rd , and sometimes 4 th digits are<br />

whole numbers<br />

(This example denotes 2 and 11)<br />

4 th digit may be part of a decimal –<br />

ex.: THO16925<br />

TFL 23118<br />

THO 35 925<br />

Letters<br />

refer to<br />

Hanger<br />

Series<br />

ex.: THO<br />

First (2)<br />

Digits<br />

refer to<br />

Member Width<br />

ex.: 3.5 inches<br />

Last (2) or<br />

(3) Digits<br />

refer to<br />

Member Height<br />

ex.: 9.25 inches<br />

-2<br />

Digits after<br />

Dash<br />

refer to<br />

Number of<br />

Plies ex.: 2 ply<br />

2 nd and 5 th digits are decimals<br />

(see guide below)<br />

(This example denotes .3125<br />

[5/16] and .875 [7/8])<br />

5 th digit may be (0) or dropped if<br />

height is even<br />

Part Number Guide for Decimals<br />

1 = .125 or 1/8 inch<br />

2 or 25 = .25 or 1/4 inch<br />

3 = .3125 or 5/16 inch<br />

5 = .5 or 1/2 inch<br />

6 = .625 or 5/8 inch<br />

7 = .75 or 3/4 inch<br />

8 = .875 or 7/8 inch<br />

Some Examples:<br />

THO15950 ................................1-1/2˝ x 9-1/2˝<br />

THF17925 ................................1-3/4˝ x 9-1/4˝<br />

THO16925-2..................double 1-5/8˝ x 9-1/4˝<br />

THF23140-2 ..................double 2-5/16˝ x 14˝<br />

Note: <strong>USP</strong>’s Full Line Catalog lists a range of<br />

heights for THF hangers. Face mount hangers<br />

can usually accommodate more than one<br />

I-Joist height. The hanger height must be tall<br />

enough to support the top chord of the I-Joist<br />

to eliminate web stiffener requirements on<br />

solid sawn or joists with web stiffeners. The<br />

THF hanger must be a minimum of 60% of the<br />

joist height.<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 213<br />

<strong>USP</strong>2240-131


Corrosion Resistant Products<br />

Corrosion Resistant<br />

214<br />

<strong>USP</strong><br />

Stock No.<br />

Triple<br />

Zinc<br />

(TZ)<br />

Hot-Dip<br />

Galvanized<br />

(HDG)<br />

Fasteners / Anchors<br />

Stainless<br />

Steel<br />

(SS)<br />

Gold<br />

Coat<br />

(GC)<br />

<strong>USP</strong><br />

Stock No.<br />

Triple<br />

Zinc<br />

(TZ)<br />

Hot-Dip<br />

Galvanized<br />

(HDG)<br />

Column / Post Caps<br />

Stainless<br />

Steel<br />

(SS)<br />

Gold<br />

Coat<br />

(GC)<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com<br />

<strong>USP</strong><br />

Stock No.<br />

Triple<br />

Zinc<br />

(TZ)<br />

Hot-Dip<br />

Galvanized<br />

(HDG)<br />

Column / Post Bases<br />

Stainless<br />

Steel<br />

(SS)<br />

AB1212-HDG X KCCQ44 X WE44 X X<br />

AB126-HDG X KCCQ46 X WE46 X<br />

AB128-HDG X KCCQ525-4 X WE66 X<br />

AB5812-HDG X KCCQ525-6 X<br />

Framing Plates & Angles<br />

BP12 X KCCQ64 X A3 X<br />

BP582 X KCCQ66 X AC5 X<br />

BP583 X KECCQ325-4 X AC7 X X<br />

HBPS12 X KECCQ325-6 X AC9 X<br />

HBPS58 X KECCQ44 X ANJ44S-HDG X<br />

LBP12-TZ X KECCQ46 X JA1 X<br />

LBP58-TZ X KECCQ525-6 X KHL33 X<br />

LBPS12-TZ X KECCQ64 X KHL35 X<br />

LBPS58-TZ X KECCQ66 X KHL37 X<br />

N10C X PB44-6TZ X X KHL43 X<br />

N10C-GC X PB66-6TZ X X KHL46 X<br />

N10-GC X PBC44-TZ X KHL55 X<br />

N16C X PBC66-TZ X KHL57 X<br />

N16C-GC X PBES44 X X KHL76 X<br />

N8-GC X PBES66 X X ML24-TZ X<br />

NA10D X PBS44 X X ML26-TZ X<br />

NA11 X PBS66 X X MP3 X<br />

NA16D X PBS66R X MP34 X X<br />

NA20D X PCM44 X MP4F X<br />

NA8D X PCM4416 X MP5 X X<br />

NA9D X PCM46 X MP6F X<br />

SSN10C X PCM4616 X MP7 X X X<br />

SSN16C X PCM4816 X MP9 X X<br />

SSN8C X PCM66 X MPA1 X X X<br />

SSNA10D X PCM6616 X<br />

Stud Plate Ties<br />

SSNA8D X Column / Post Bases<br />

RSPT6 X<br />

THR1218-HDG X APB44 X RSPT6-2 X<br />

THR1224-HDG X APB66 X SPT22 X<br />

THR1236-HDG X CBSQ44-TZ X X SPT24 X<br />

THR125-HDG X CBSQ46-TZ X X SPT4 X<br />

THR126-HDG X CBSQ66-TZ X X SPT6 X<br />

THR128-HDG X D44-TZ X SPT8 X<br />

THR5812-HDG X D46 X SPTH4 X<br />

THR5816-HDG X D46R-TZ X SPTH6 X<br />

THR585-HDG X D66 X SPTH8 X<br />

THR588-HDG X D66R X<br />

Lateral Joist <strong>Connectors</strong><br />

WS15-GC X EBG44-TZ X LJC-TZ X<br />

Holdowns / Foundation Anchors<br />

EPB4408 X LJQ15-TZ X<br />

FA3 X EPB4608 X LJQ17-TZ X<br />

PA18 X EPB6608 X LJQ20-TZ X<br />

PA23 X EPBH44 X LJQ23-TZ X<br />

PA28 X EPBH46R X LJQ25-TZ X<br />

RP6 X EPBH66 X LJQ35-TZ X<br />

ST1-TZ X EPBH66R X<br />

Twist Straps<br />

ST2-TZ X KCBQ44 X HTW20 X<br />

STB16 X KCBQ46 X LTW12 X<br />

STB20 X KCBQ66 X LTW18 X<br />

STB24 X KCBQ88 X MTW12 X<br />

STB28 X PA44E X X MTW16 X<br />

STB34 X PA44 X MTW20 X X<br />

STBL24 X PA46E X X MTW30 X<br />

STBL28 X PA46 X<br />

Straps<br />

TA51 X PA66E X X HRS416-TZ X<br />

TA71 X PA66ER-TZ X HTP37-TZ X<br />

TDL5 X PA66R X KRPS22 X<br />

TDX2-TZ X PA66 X KRPS28 X<br />

Column / Post Caps<br />

PAU44 X X KST227 X<br />

BC400-TZ X PAU46 X X KST237 X<br />

C44 X X PAU66 X X KST248 X<br />

C46 X PAU88 X X KST260 X<br />

C46R X RSCH44 X L6 X<br />

C66 X RSCH66 X LH12 X<br />

C66R X WAS44 X X LSTA36 X<br />

KCCQ325-4 X WAS46 X MSTA12 X X<br />

KCCQ325-6 X WAS66 X X MSTA15 X<br />

Gold<br />

Coat<br />

(GC)<br />

continued on next page<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®


Corrosion Resistant Products continued<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

<strong>USP</strong><br />

Stock No.<br />

Triple<br />

Zinc<br />

(TZ)<br />

Hot-Dip<br />

Galvanized<br />

(HDG)<br />

Straps<br />

Stainless<br />

Steel<br />

(SS)<br />

Gold<br />

Coat<br />

(GC)<br />

<strong>USP</strong><br />

Stock No.<br />

Triple<br />

Zinc<br />

(TZ)<br />

Hot-Dip<br />

Galvanized<br />

(HDG)<br />

<strong>Hangers</strong><br />

Stainless<br />

Steel<br />

(SS)<br />

MSTA18 X X SKHH210L-2 X<br />

MSTA21 X SKHH210L-2IF X<br />

MSTA24 X X SKHH210R-2 X<br />

MSTA30 X SKHH210R-2IF X<br />

MSTA36 X X SKHH410L X<br />

MSTA9 X SKHH410LIF X<br />

MSTAM24 X SKHH410R X<br />

MSTAM36 X SKHH410RIF X<br />

RS150 X SKHH414LIF X<br />

T6 X SKHH414RIF X<br />

<strong>Hangers</strong><br />

SKHH46L<br />

X<br />

HD210-2IF X X SKHH46LIF X<br />

HD210-3IF X SKHH46R X<br />

HD28-2IF X SKHH46RIF X<br />

HD410 X THD28-2 X<br />

HD410IF X THD410 X<br />

HD412 X THD46 X<br />

HD412IF X THD48 X<br />

HD44IF X THDH412 X<br />

HD46<br />

X<br />

Hurricane / Seismic Anchors<br />

HD46IF X HHCP2 X<br />

HD48 X LFTA6 X<br />

HD48IF X RT10 X X<br />

HD610 X RT15 X X<br />

HD610IF X RT16-2 X X<br />

HD612 X RT16A X X<br />

HD612IF X RT20 X<br />

HD68 X RT3A X X<br />

HD68IF X RT4 X X<br />

HDQ612IF X RT5 X X<br />

HUS210 X RT7 X X<br />

HUS210-2IF X RT7A X X<br />

HUS212-2 X RT8A X X<br />

HUS26<br />

X<br />

Miscellaneous<br />

HUS28 X CSH-TZ X<br />

HUS28-2IF X DC50-TZ X<br />

JL210IF-TZ X X DTB-TZ X X<br />

JL24IF-TZ X ERB24-TZ X<br />

JL26IF-TZ X X FB14-TZ X<br />

JL28IF-TZ X FB23-TZ X<br />

JPF24 X FB26-TZ X<br />

JPF26 X FC24-TZ X<br />

JUS210 X X X FPH24-TZ X<br />

JUS210-2 X X X FRB24-TZ X<br />

JUS210-3 X X ICPL516-TZ X<br />

JUS24 X X X ICPL58 X<br />

JUS24-2 X PRT15-TZ X<br />

JUS26 X X X PRT2H-TZ X<br />

JUS26-2 X X X PRT2-TZ X<br />

JUS28 X X X PRTIC2-TZ X<br />

JUS28-2 X X SCA10-TZ X<br />

JUS28-3 X SCA9-GC X<br />

JUS36 X SCA9-TZ X<br />

JUS410 X SDJT14-TZ X<br />

JUS44 X SDPT5-TZ X<br />

JUS46 X SDPT7-TZ X<br />

JUS48 X TTA12-TZ X<br />

LSSH15-TZ X X TTA2-TZ X<br />

LSSH210 X X TTB22-TZ X<br />

LSSH31 X TTC24-TZ X<br />

MSH422 X TTC42-TZ X<br />

SKH210L X X X TTF22-TZ X<br />

SKH210L-2 X TTR-TZ X<br />

SKH210R X X X TTU2-TZ X<br />

SKH210R-2 X WT17HD-75 X<br />

SKH26L X X X WT22 X<br />

SKH26R X X X<br />

SKH28L<br />

X<br />

SKH28R<br />

X<br />

Gold<br />

Coat<br />

(GC)<br />

Corrosion Resistant<br />

1-800-328-5934 • www.<strong>USP</strong>connectors.com 215<br />

<strong>USP</strong>2240-131


High Performance Corrosion Resistance<br />

It’s the new gold standard from <strong>USP</strong>!<br />

<strong>USP</strong> Structural <strong>Connectors</strong> offers anchors, hangers, framing angles, straps, and fasteners in Gold Coat for 2x<br />

the corrosion resistance protection. Gold Coat is a multi-layer protection system that protects the integrity of<br />

the structural connector by offering two layers of corrosion resistance. The top layer is a specially formulated<br />

organic polymer barrier designed specifically for outdoor applications and contact with treated wood.<br />

Finish: Gold Coat<br />

<br />

<br />

<br />

<br />

<br />

<br />

Gold Coat testing<br />

indicates significant<br />

Corrosion Resistance<br />

over traditional Zinc<br />

Galvanization alone and<br />

performance closer to<br />

Stainless Steel<br />

Structural grade<br />

steel base material<br />

Thermally bonded<br />

zinc galvanization<br />

Gold Coat organic<br />

polymer barrier


Testing! Testing! Testing!<br />

It’s part of our continuous commitment to<br />

innovation and quality.<br />

At <strong>USP</strong>, quality doesn’t just happen.<br />

It’s a result of constant research,<br />

testing and improving. Connect with<br />

confidence. Specify <strong>USP</strong> <strong>Connectors</strong>.


The <strong>USP</strong> Specifier <br />

Instant product and design information<br />

when you need it<br />

• Designed for engineers and estimators<br />

• Manage the complexity of the proper<br />

selection of hangers<br />

• Provide project management and cost<br />

control<br />

• Generate summary reports, bid and<br />

connector conversion information<br />

• Conveniently transfer project summary,<br />

schedule tables and installation details<br />

to CAD working drawings....and much<br />

more<br />

Our <strong>USP</strong> Specifi er software puts you in<br />

command with instant product and design<br />

information. Search through our comprehensive<br />

catalog of connectors, compare products, price out<br />

jobs and produce the most accurate, cost effective<br />

solutions possible.<br />

We are committed to providing you with the<br />

best software tools possible to make your job<br />

easier. Download your copy of The <strong>USP</strong> Specifi er<br />

today.


:<br />

Our commitment to technology!<br />

<strong>USP</strong> Mobile Solutions<br />

<strong>USP</strong> Software Solutions<br />

© Copyright 2013 <strong>USP</strong> Structural <strong>Connectors</strong> ®<br />

The <strong>USP</strong> Deck Designer. Online anytime.<br />

The easy yet comprehensive deck design tool<br />

helps you design the perfect deck, generate<br />

3D views, specifications, materials list and<br />

building permit applications.<br />

iPad ® Catalog. Download our entire<br />

catalog to your iPad ® . Quickly search<br />

products by application.<br />

QR Codes. Scan QR codes on your smart<br />

phone before you buy. Quickly look up<br />

product information to make the right<br />

choice.<br />

Sapphire Supply- 3D design and layout<br />

software for your <strong>EWP</strong> and Lumber design<br />

needs and tools for doing layout and take-off<br />

for whole house estimation.<br />

Sapphire Build.<br />

Design software for<br />

modeling building<br />

in 3D and track<br />

vertical load distribution<br />

throughout<br />

the structure; roof to foundation, to optimize<br />

structural member design.<br />

Black Point Option Manager. Designed<br />

for the residential builder, now you can easily<br />

manage options and material take-offs.


Connect with Confidence!<br />

MANUFACTURING & WAREHOUSE FACILITIES<br />

Minnesota<br />

Montgomery, Minnesota<br />

Arizona<br />

Tolleson, Arizona<br />

Northern California<br />

Livermore, California<br />

New Jersey Warehouse<br />

Lumberton, New Jersey<br />

MONTGOMERY, MN<br />

THORNHILL, ON, CA<br />

LUMBERTON, NJ<br />

Southern California<br />

Corona, California<br />

Texas Warehouse<br />

Humble, Texas<br />

LIVERMORE, CA<br />

CORONA, CA<br />

TOLLESON, AZ<br />

Florida<br />

Largo, Florida<br />

Canada<br />

Thornhill, ON Canada<br />

HUMBLE, TX<br />

LARGO, FL<br />

<strong>USP</strong> Structural <strong>Connectors</strong> Corporate Office: 14305 Southcross Drive-Suite 200, Burnsville, Minnesota 55306<br />

(952) 898-8772 • (800) 328-5934 • www.<strong>USP</strong>connectors.com<br />

Follow us on: www.facebook.com/uspconnectors www.twitter.com/uspconnectors<br />

©2014 MiTek USA, Inc. <strong>USP</strong> 2240-141R

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!