You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Power</strong> <strong>Supplies</strong><br />
Uninterruptible power supply<br />
for AC grids
Interference-free mains supply<br />
and signal transmission<br />
A constant power supply is essential for the<br />
operational reliability of electrical systems,<br />
installations and devices.<br />
These requirements are satisfied by the<br />
class VFI-SS-111 single-phase power supply<br />
units. They are available as stand-alone<br />
device or for mounting in a 19“ rack.<br />
<strong>Phoenix</strong> <strong>Contact</strong> offers a compatible range of<br />
products for your power supply solution in the<br />
control cabinet. <strong>Power</strong> supply units, DC/DC<br />
converters and redundancy modules as well as<br />
uninterruptible power supply units for the control<br />
cabinet ensure maximum system availability.<br />
Further information can be obtained from the<br />
<strong>Power</strong> <strong>Supplies</strong> for Maximum System Availability<br />
brochure.<br />
2 PHOENIX CONTACT
Table of contents<br />
Constant power supply and<br />
improved power quality<br />
UPS compact: multifunctional<br />
for single-phase applications<br />
Page 4<br />
Page 6<br />
1 to 3 kVA<br />
Compact UPS solutions<br />
with 1 to 3 kVA power<br />
Page 8<br />
Accessories for UPS-CP devices<br />
with 1 to 3 kVA power<br />
Page 10<br />
4.5 to 6 kVA<br />
Redundant UPS solutions<br />
with 4.5 to 6 kVA power<br />
Page 12<br />
Accessories for UPS-CP devices<br />
with 4.5 to 6 kVA power<br />
Page 14<br />
Reliable protection against voltage interruptions<br />
Within power supply networks, even<br />
the slightest voltage fluctuations or<br />
power failures can cause significant<br />
disturbances in IT systems. Devices for<br />
uninterruptible power supply intercept<br />
these mains faults and ensure a constant<br />
supply voltage via battery support.<br />
Computer crashes, program errors<br />
or data loss are therefore effectively<br />
prevented.<br />
Loads are permanently supplied with an<br />
output voltage or output frequency that<br />
is independent of the mains input.<br />
43.8%<br />
Brief interruption – huge effect<br />
Recent VDE studies on quality of supply have shown that<br />
the risk of mains failures and brief interruptions is on the<br />
increase.* The average failure time per year increased from<br />
15 to 23 minutes.<br />
* Source: „Betriebsichere Rechenzentren – Leitfaden“, BITKOM<br />
Bundesverband Informationswirtschaft,Telekommunikation und neue Medien e.V.<br />
29.2%<br />
21.9%<br />
1.5%<br />
3.6%<br />
0–10 ms 10–20 ms 20 ms–1 s 1 s–1 h > 1 h<br />
PHOENIX CONTACT 3
Constant power supply<br />
and improved power quality<br />
UPS devices are an important measure<br />
for reliable power quality. They bridge<br />
current failures and eliminate other power<br />
malfunctions such as:<br />
• Undervoltages or surge voltages<br />
• High-frequency noises<br />
• Frequency fluctuations<br />
• Harmonics<br />
UPS devices for key areas of the company<br />
All devices of the UPS-CP series are VFI-SS-111-classified.<br />
They provide the right protective solution for all typical<br />
interferences and interruptions.<br />
The UPS classification code as per IEC 62040-3<br />
Output behavior in normal mode<br />
VFI (class 1):<br />
Voltage and Frequency Independent<br />
(Online)<br />
VI (class 2):<br />
Voltage Independent<br />
(Line-Interactive)<br />
VFD (Class 3):<br />
Voltage and Frequency Dependent<br />
(Offline)<br />
VFI SS 111<br />
Output behavior of the voltage curves 1)<br />
S = Sinusoidal voltage curve in the case of linear and non-linear load<br />
(values < IEC 61000-2-2; D < 0.08)<br />
X = Sinusoidal voltage curve for linear load (non-linear: D > 0.08)<br />
Y = Non-sinusoidal voltage curve (Values > IEC 61000-2-2)<br />
1)<br />
First position: Specification of normal mode<br />
Second position: Specification of battery mode<br />
Dynamics of the output behaviors 2)<br />
1 = Interruption-free<br />
2 = Voltage interruption < 1 ms<br />
3 = Voltage interruption < 10 ms<br />
4 = Individual as per the manufacturer<br />
2)<br />
First number: When changing the operating mode<br />
Second number: In the case of the maximum linear load jump<br />
Third number: In the case of the maximum non-linear load jump<br />
4 PHOENIX CONTACT
The top features of the UPS-CP series<br />
Long-life batteries<br />
The special regulating<br />
function for the charging<br />
of the UPS-CP devices<br />
ensures a ripple-free DC<br />
voltage without higher-level<br />
alternating currents.<br />
Integrated safety<br />
switch-off<br />
If required, the UPS-CP<br />
devices can be integrated<br />
into a safety concept via<br />
a two-pole connection.<br />
Simple battery<br />
replacement<br />
(Hot-Swap)<br />
A battery can be replaced<br />
without problems while the<br />
device is still installed. This<br />
applies to both UPS devices<br />
and battery modules.<br />
Choice of stand-alone<br />
or 19" rack use<br />
The operating panel of<br />
the UPS-CP devices can be<br />
rotated by 90° to ensure<br />
optimum legibility of the<br />
display for the particular<br />
application.<br />
UPS device classes and operating functions (IEC 62040-3)<br />
VFI (class 1 / Online)<br />
VI (class 2 / Line-Interactive)<br />
VFD (class 3 / Offline)<br />
Mains failure Voltage dips Voltage<br />
peaks<br />
Undervoltages<br />
Overvoltages<br />
Transient<br />
overvoltages<br />
Voltage<br />
surges<br />
Frequency<br />
fluctuations<br />
Voltage<br />
distortions<br />
Harmonics<br />
Duration of interference / characteristic<br />
> 10 ms > 10 ms > 10 ms Constant Constant<br />
Sporadic<br />
350 μs<br />
< 4 ms Sporadic Periodic Constant<br />
Additionally recommended solutions for surge protection (IEC 60364-5-534)<br />
Type 1<br />
Type 1/2<br />
Type 2<br />
Type 1<br />
Type 1/2<br />
We recommend the use of additional surge protection devices. For more information, visit www.phoenixcontact.com<br />
PHOENIX CONTACT 5
UPS compact: Multifunctional<br />
for single-phase applications<br />
The UPS devices of the UPS-CP series are<br />
suitable for a wide range of applications.<br />
The system can be configured as per the<br />
requirement and the operating environment.<br />
Other battery, bypass or parallel<br />
modules expand the application profile<br />
of the UPS-CP devices.<br />
*<br />
High system integration<br />
The driver and monitor software of the<br />
UPS-CP series supports the most common<br />
operating systems. The latest versions are<br />
available under: www.phoenixcontact.com<br />
* The logos depicted are international trademarks of<br />
their owners in their respective countries.<br />
MTTR – Bypass modules ensure minimum service times<br />
Mean time to recover – Minimum possible time is important for<br />
professional applications. The UPS-CP series fulfills this requirement<br />
completely with the separate bypass modules. In the 4.5 and 6 kVA<br />
performance class, even redundant or parallel operation of the<br />
devices is possible.<br />
Bypass module<br />
For the UPS-CP devices<br />
with 1 to 3 kVA power<br />
• Including connection and<br />
distributor cables:<br />
- 1 x IEC C19 on C20<br />
- 1 x IEC C20 on C13<br />
- 1 x IEC C19 on C14<br />
• Including installation material<br />
See page 10<br />
Bypass module<br />
For the UPS-CP devices<br />
with 4.5 to 6 kVA power<br />
• Including installation material<br />
See page 13<br />
Parallel unit<br />
For the UPS-CP devices<br />
with 4.5 to 6 kVA power<br />
• Parallel or redundant<br />
operation of two UPS<br />
devices (1+1 switching)<br />
• With bypass function<br />
• Including installation material<br />
See page 15<br />
Parallel unit<br />
For the UPS-CP devices<br />
with 4.5 to 6 kVA power<br />
• Parallel or redundant<br />
operation of three UPS<br />
devices (2+1 switching)<br />
• With bypass function<br />
• Including installation material<br />
See page 15<br />
6 PHOENIX CONTACT
INPUT<br />
BREAKER<br />
AC INPUT<br />
AC OUTPUT<br />
INPUT<br />
BREAKER<br />
AC INPUT<br />
INPUT<br />
BREAKER<br />
AC INPUT<br />
Wide-reaching configuration using hardware or software<br />
The UPS-CP devices can be directly configured via<br />
the operating panel and in the case of charged batteries<br />
even without external power connection.<br />
The illuminated and easily legible LCD operating<br />
panel provides information about important status<br />
parameters such as the charging status or the<br />
supply voltage. The additional software also enables<br />
controlled shutdown of a computer via a program<br />
command.<br />
The optional SNMP extension cards can be used<br />
for comprehensive administration of the<br />
UPS-CP devices through the grid. Access is simply<br />
via the web browser, where logs can be called up<br />
or planned actions programmed.<br />
The current software versions are available in the<br />
E-shop of <strong>Phoenix</strong> <strong>Contact</strong> for download.<br />
LED for quick status check<br />
Illuminated LCD operating panel<br />
Large function keys<br />
Operating panel of<br />
1 to 3 kVA devices<br />
Operating panel of<br />
4.5 to 6 kVA devices<br />
Expandable communication interfaces<br />
In addition to the existing interfaces such as the RS-232 or USB connection,<br />
all UPS-CP devices can be expanded with the SNMP/MODBUS network cards.<br />
AC OUTPUT<br />
AC OUTPUT<br />
INTERFAC<br />
E<br />
INTERFAC<br />
E<br />
INTERFAC<br />
E<br />
Network card<br />
UPS-SNMP-CARD<br />
Order No. 2800289<br />
• ETHERNET 10/100 Mbit Base-T<br />
(Auto-Sense)<br />
• Status LED<br />
Network card<br />
UPS-SNMP-CARD E<br />
Order No. 2800290<br />
• ETHERNET 10/100 Mbit Base-T<br />
(Auto-Sense)<br />
• MODBUS<br />
• AUX<br />
• D-SUB adapter cable<br />
• Status LED<br />
Relay card<br />
UPS-6REL<br />
Order No. 2800287<br />
Floating switching contacts for status<br />
messages through:<br />
• Bypass mode / Voltage supply / Inverter<br />
mode / Battery voltage / Battery status /<br />
Common alarm<br />
• Switching contacts for safety shutdown<br />
PHOENIX CONTACT 7
IN 1 2 BY<br />
UPS compact – 1000 VA Ord. –No.: 2800274<br />
ON<br />
OFF<br />
Enter<br />
Function<br />
!<br />
ON<br />
ON<br />
www.phoenixcontact.com<br />
IN 1 2 BY<br />
!<br />
IN 1 2 BY<br />
UPS compact – 1000 VA Ord. –No.: 2800274<br />
ON<br />
OFF<br />
ON<br />
OFF<br />
ON<br />
Enter<br />
Function<br />
!<br />
ON<br />
ON<br />
ON<br />
www.phoenixcontact.com<br />
Compact UPS solutions<br />
with 1 to 3 kVA power<br />
UPS compact – 1000 VA Ord. –No.: 2800274<br />
Enter<br />
Function<br />
www.phoenixcontact.com<br />
The UPS-CP devices with 1 to 3 kVA<br />
power are complete UPS solutions with<br />
control unit and batteries integrated in<br />
one housing.<br />
Additional battery modules extend the<br />
bridging times.<br />
The UPS devices and battery modules<br />
are delivered along with all the necessary<br />
connecting cables and installation materials.<br />
Thanks to the supplied installation<br />
materials and the rotatable<br />
display, the UPS devices can be<br />
used as 19" rack modules or as<br />
floor-mounted devices.<br />
UPS<br />
UPS-CP with 1 to 3 kVA<br />
General features:<br />
• 1 to 2 kVA: 6 x 10 A IEC outputs<br />
• 3 kVA: 1 x 16 A, 4 x 10 A IEC outputs<br />
• Two 10 A IEC outputs that can be switched<br />
via a software command<br />
• Complete solutions with internal batteries<br />
• Can be combined with external bypass<br />
modules and sockets<br />
• Serial USB and RS-232 interface<br />
Technical data:<br />
• VFI-SS-111 classified<br />
• <strong>Power</strong> factor: 0.8<br />
• Input: 160 ... 288 V AC (50/60 Hz)<br />
• Output (adjustable):<br />
200/208/220/230/240V AC (50/60 Hz)<br />
• Switch-over time: 0 ms<br />
• Crest factor: 3:1<br />
Time (min)<br />
1 kVA UPS-CP-1KVA/240AC<br />
Order No. 2800274<br />
UPS with 3 internal batteries<br />
P1<br />
without additional battery<br />
1 x P1<br />
2 x P1 or 1 x P2<br />
UPS-CP-BAT-1KVA-P1<br />
Order No. 2800280<br />
Battery module with 2 x 3 batteries<br />
Nominal real power (W)*<br />
P2<br />
UPS-CP-BAT-1KVA-P2<br />
Order No. 2800281<br />
Battery module with 4 x 3 batteries<br />
* Real power = Apparent power x <strong>Power</strong> factor<br />
8 PHOENIX CONTACT
EPO<br />
EPO<br />
EPO<br />
G<br />
DC 36V<br />
AC INPUT<br />
INPUT<br />
BREAKER<br />
G<br />
DC 72V<br />
G<br />
DC 72V<br />
1 2<br />
INPUT<br />
BREAKER<br />
1 2<br />
INPUT<br />
BREAKER<br />
INPUT<br />
BREAKER<br />
INPUT<br />
BREAKER<br />
INPUT<br />
BREAKER<br />
1<br />
AC OUTPUT<br />
2<br />
AC INPUT<br />
AC INPUT<br />
Switchable supply connections<br />
1 kVAG<br />
2 kVA<br />
INTERFACE E<br />
AC OUTPUT<br />
INTERFACE E<br />
In the case of UPS devices with<br />
1 to 3 kVA, two outputs each can<br />
be switched without voltage via<br />
a software command.<br />
In critical situations, the energy<br />
saved at these outputs is available<br />
for the more important devices.<br />
3 kVA<br />
AC OUTPUT<br />
INTERFACE E<br />
Battery<br />
The maximum expected bridging time of a UPS-CP device<br />
depends on the connected payload.<br />
Depending on the type and number of additional battery<br />
modules, refer to the diagrams for the corresponding longer<br />
bridging times.<br />
Time (min)<br />
Time (min)<br />
without additional battery<br />
Nominal real power (W)*<br />
1 x P3 3 x P3<br />
2 x P3 or 1 x P4 4 x P3 or 2 x P4<br />
without additional battery<br />
Nominal real power (W)*<br />
1 x P3 3 x P3<br />
2 x P3 or 1 x P4 4 x P3 or 2 x P4<br />
2 kVA UPS-CP-2KVA/240AC<br />
Order No. 2800275<br />
UPS with 6 internal batteries<br />
3 kVA UPS-CP-3KVA/240AC<br />
Order No. 2800276<br />
UPS with 6 internal batteries<br />
P3<br />
UPS-CP-BAT-2/3KVA-P3<br />
Order No. 2800283<br />
P3<br />
UPS-CP-BAT-2/3KVA-P3<br />
Order No. 2800283<br />
Battery module with 6 batteries<br />
Battery module with 6 batteries<br />
P4<br />
UPS-CP-BAT-2/3KVA-P4<br />
Order No. 2800284<br />
P4<br />
UPS-CP-BAT-2/3KVA-P4<br />
Order No. 2800284<br />
Battery module with 2 x 6 batteries<br />
Battery module with 2 x 6 batteries<br />
PHOENIX CONTACT 9
Accessories for UPS-CP devices<br />
with 1 to 3 kVA power<br />
In addition to the general expansion<br />
options such as SNMP or relay cards,<br />
more accessories are also available for the<br />
UPS-CP devices with 1 to 3 kVA power.<br />
All bypass modules and sockets are delivered along<br />
with the fastening material for rack mounting.<br />
The UPS system can be added and<br />
expanded to match the prevailing<br />
conditions.<br />
C20<br />
C19<br />
C20<br />
C13<br />
C14<br />
C19<br />
DIN rail 19’’<br />
Bypass for 1 to 3 kVA UPS<br />
UPS-CP-19’’MR<br />
Order No. 2800288<br />
When planning a rack, the weight of the individual devices is an<br />
important aspect. The rails support the heavy UPS devices and<br />
battery modules. These accessories are indispensable for a stable<br />
and safe rack.<br />
Properties:<br />
• Max. carrying capacity: 50 kg per rail (total 100 kg)<br />
• Dimensions: 520 x 50 x 90 mm<br />
• Individual extension length: 520 – 880 mm<br />
• Weight: 2.6 kg<br />
UPS-CP-BP-1/2/3KVA<br />
Order No. 2800291<br />
The external bypass module reduces the service times<br />
considerably since it allows a quick change of a complete<br />
UPS housing without intervention into the installation.<br />
Properties:<br />
• Nominal voltage: 240 V AC<br />
OUTPUT<br />
BREAKER<br />
PUSH TO RESET<br />
• Nominal current: 16 A<br />
• Inputs: 1 x IEC connector C20<br />
• Outputs: 6 x socket C13, 1 x socket C19<br />
• Weight: 3.8 kg<br />
• Dimensions: 88.89 x 482.6 OUTPUT 10A x MA.X 120 mm<br />
Accessories (including):<br />
• 1 x adapter cables (1.8 m)<br />
Connector C20 Socket C19<br />
• 1 x adapter cables (1.8 m)<br />
Connector C20 Socket C13<br />
• 1 x adapter cables (1.8 m)<br />
Connector C14 Socket OUTPUT 10A C19 MA.X<br />
• Installation material<br />
OUTPUT<br />
BREAKER<br />
PUSH TO RESET<br />
TO UPS OUTPUT T<br />
TO UPS OUTPUT T<br />
UPS<br />
AVAILABLE<br />
UPS<br />
UPS active<br />
UPS<br />
AVAILABLE<br />
UPS<br />
MAINTANANCE<br />
AVAILABLE<br />
UTILITY<br />
MAINTANANCE<br />
AVAILABLE<br />
<strong>Power</strong> supply<br />
active<br />
UTILITY<br />
BYPASS<br />
BYPASS<br />
UTILITY<br />
UTILITY<br />
10 PHOENIX CONTACT
AC INTPUT<br />
AC OUTPUT<br />
Easy replacement of the internal batteries<br />
In the case of the UPS-CP devices and the battery modules,<br />
the internal battery blocks can be replaced easily.<br />
Thanks to the hot-swap technology, replacement is possible<br />
during operation and with the device still installed.<br />
C14 C19 C14 C13<br />
C20<br />
C19<br />
Socket strip 9 x 10 A<br />
UPS-CP-MS-9x10A-IEC<br />
Order No. 2800293<br />
Multiple socket strip with 3 x 3 IEC 60320 C13 sockets.<br />
Every group of three is separately fused with 10 A.<br />
Socket strip 4 x 16 A<br />
UPS-CP-MS-4x16A-IEC<br />
Order No. 2800294<br />
Multiple socket with four IEC 60320<br />
C19 outputs sockets.<br />
Properties:<br />
• Nominal voltage: 240 V AC<br />
• Nominal current: OUTPUT 16 A (input) / 10 A (output)<br />
BREAKER<br />
PUSH TO RESET<br />
• Input: 1 x IEC connector C20<br />
• Output: 9 x IEC socket C13<br />
• Weight: 1.8 kg<br />
• Dimensions: 44.45 x 482.6 x 90 mm<br />
CONNECT UPS<br />
LINE CORD HERE<br />
CONNECT UPS<br />
LINE CORD HERE<br />
OUTPUT 16A MAX.<br />
OUTPUT 10A MAX.<br />
Accessories (including):<br />
• 1 x adapter cables (1.8 m)<br />
Connector C14 OUTPUT Socket C19<br />
BREAKER<br />
PUSH TO RESET<br />
• 5 x adapter cables (1.8 m)<br />
Connector C14 Socket C13<br />
• Installation material<br />
BREAKER<br />
Properties:<br />
• Nominal voltage: 240 V AC<br />
• Nominal current: 16 A (input/output)<br />
• Input: 1 x IEC connector C20<br />
• Output: 4 x IEC socket C19<br />
• Weight: 1.8 kg<br />
• Dimensions: 44.45 x 482.6 x 90 mm<br />
Accessories (including):<br />
• 6 x adapter cables (1.8 m)<br />
Connector C20 Socket C19<br />
• Installation material<br />
BREAKER<br />
OUTPUT 16A MAX.<br />
OUTPUT 10A MAX.<br />
10A<br />
10A<br />
AC INTPUT<br />
AC OUTPUT<br />
10 A fuse<br />
Assembly variants<br />
PHOENIX CONTACT 11
Redundant UPS solutions<br />
with 4.5 to 6 kVA power<br />
If you need more power, the UPS-CP<br />
devices with 4.5 or 6 kVA provide<br />
the correct solution. Devices of this<br />
performance class can also be operated<br />
parallelly or redundantly and thus ensure<br />
additional performance reserves and<br />
increased availability. A functional unit<br />
always consists of a UPS device and a<br />
separate battery module.<br />
UPS<br />
Battery<br />
4,5 kVA<br />
UPS-CP with 4.5 to 6 kVA<br />
General features:<br />
• Pluggable input/output connections<br />
• <strong>Power</strong> up to 12 kVA (parallel mode)<br />
• Parallel/redundancy mode<br />
(Communication via CAN Bus interfaces)<br />
• Can be combined with external bypass modules<br />
and sockets<br />
• Serial RS-232 interface<br />
• All required connecting cables are supplied<br />
with the devices<br />
Technical data:<br />
• VFI-SS-111 classified<br />
• <strong>Power</strong> factor: 0.7<br />
• Input: 160 ... 280 V AC (50/60 Hz)<br />
• Output (adjustable):<br />
200/208/220/230/240V AC (50/60 Hz)<br />
• Switch-over time: 0 ms<br />
• Crest factor: 3:1<br />
Time (min)<br />
1 x P5<br />
2 x P5 4 x P5<br />
3 x P5 5 x P5<br />
4,5 kVA UPS-CP-4.5KVA/240AC<br />
Order No. 2800277<br />
UPS<br />
P5<br />
UPS-CP-BAT-4.5/6KVA-P5<br />
Order No. 2800285<br />
Battery module with 20 batteries<br />
Nominal real power (W)*<br />
The maximum expected bridging time of a UPS-CP device<br />
depends on the connected payload. Depending on the type<br />
* Real power = Apparent power x <strong>Power</strong> factor<br />
12 PHOENIX CONTACT
1<br />
2<br />
N+1 ECO<br />
UPS compact – 4500 VA Ord. –No.: 2800277<br />
ON<br />
OFF<br />
Enter<br />
!<br />
ON<br />
Function ON<br />
www.phoenixcontact.com<br />
1<br />
2<br />
ON<br />
N+1 ECO<br />
UPS compact – 6000 VA Ord. –No.: 2800278<br />
OFF<br />
Enter<br />
!<br />
ON<br />
Function ON<br />
www.phoenixcontact.com<br />
USV<br />
Bypass<br />
INPUT<br />
OUTPUT<br />
Short service times when using the bypass module<br />
Due to high current outputs, the 4.5 and<br />
6 kVA UPS devices are connected directly<br />
to the fixed installation.<br />
IN<br />
OUT<br />
IN<br />
OUT<br />
Basic structure<br />
4.5 and 6 kVA UPS configurations always<br />
consist of a UPS device and a battery<br />
module. If they are operated via the standard<br />
connecting cable, the connected system must<br />
always be switched off too for replacement.<br />
Basic structure + Bypass module<br />
The bypass module can be used instead of<br />
the provided connecting cable. If servicing<br />
is necessary, a fast replacement of the UPS<br />
system is possible without having to switch<br />
off the system.<br />
UPS<br />
Battery<br />
6 kVA<br />
Time (min)<br />
External bypass module<br />
UPS-CP-BP-4.5/6KVA<br />
Order No. 2800292<br />
A bypass module is always suitable for a functional unit comprising<br />
a UPS device (4.5/6 kVA) and a battery module.<br />
1 x P5<br />
2 x P5 4 x P5<br />
3 x P5 5 x P5<br />
6 kVA UPS-CP-6KVA/240AC<br />
Order No. 2800278<br />
UPS<br />
Nominal real power (W)*<br />
Properties:<br />
• Nominal voltage: 240 V AC<br />
• Nominal current: 32 A<br />
• Weight: 6.3 kg<br />
• Dimensions: 88.89 x 482.6 x 280 mm<br />
Accessories (including):<br />
• Installation material<br />
P5<br />
UPS-CP-BAT-4.5/6KVA-P5<br />
Order No. 2800285<br />
Battery module with 20 batteries<br />
and number of additional battery modules, refer to the<br />
diagrams for the corresponding longer bridging times.<br />
PHOENIX CONTACT 13
Accessories for UPS-CP devices<br />
with 4.5 to 6 kVA power<br />
The devices of the 4.5 and 6 kVA<br />
performance class have been especially<br />
designed for parallel and redundant<br />
use. Depending on the basic device,<br />
configurations with 9 or 12 kVA are<br />
possible.<br />
C14 C13 C20 C19<br />
DIN rail 19’’<br />
19’’ Multiple socket strip<br />
UPS-CP-19’’MR<br />
Order No. 2800288<br />
When planning a rack, the weight of the individual devices is an<br />
important aspect. The rails help support the heavy UPS devices<br />
and battery modules. These accessories are indispensable for a<br />
stable and safe rack.<br />
Properties:<br />
• Max. carrying capacity: 50 kg per rail (total 100 kg)<br />
• Dimensions: 520 x 50 x 90 mm<br />
• Individual extension length: 520 BREAKER – 880 mm<br />
• Weight: 2.6 kg<br />
UPS-CP-MS-5x16A/9x10A-IEC<br />
Order No. 2800296<br />
This multiple socket strip has five separately secured C19 sockets<br />
and three secured three groups with C13 sockets.<br />
Properties:<br />
Nominal voltage: 240 V AC<br />
Nominal current: 16 A (input/output)<br />
Input: 1 x IEC connector C20<br />
Output: 4 x IEC socket C19<br />
BREAKER<br />
Weight: 1.8 kg<br />
Dimensions: 44.45 x 482.6 x 90 mm<br />
10 A fuse<br />
BREAKER<br />
AC OUTPUT<br />
BREAKER<br />
BREAKER<br />
16A<br />
BREAKER<br />
10A<br />
10A<br />
BREAKER<br />
BREAKER<br />
16A<br />
BREAKER<br />
16A<br />
BREAKER<br />
10A<br />
Accessories (including):<br />
• 6 x adapter cables (1.8 m)<br />
Connector C14 Socket C13<br />
10A<br />
BREAKER<br />
BREAKER<br />
• 5 x adapter cables (1.8 m)<br />
Connector C20<br />
• Installation material<br />
Socket C19<br />
BREAKER<br />
16A<br />
16 A fuse<br />
BREAKER<br />
10A<br />
10A<br />
BREAKER<br />
BREAKER<br />
16A<br />
AC OUTPUT<br />
16A<br />
16A<br />
16A<br />
16A<br />
16A<br />
14 PHOENIX CONTACT
1<br />
2<br />
ON<br />
N+1 ECO<br />
UPS compact – 4500 VA Ord. –No.: 2800277<br />
1<br />
2<br />
ON<br />
OFF<br />
Enter<br />
!<br />
ON<br />
Function ON<br />
www.phoenixcontact.com<br />
N+1 ECO<br />
UPS compact – 4500 VA Ord. –No.: 2800277<br />
OFF<br />
Enter<br />
!<br />
ON<br />
Function ON<br />
www.phoenixcontact.com<br />
USV<br />
Bypass<br />
INPUT<br />
OUTPUT<br />
1<br />
2<br />
ON<br />
N+1 ECO<br />
UPS compact – 6000 VA Ord. –No.: 2800278<br />
1<br />
2<br />
ON<br />
OFF<br />
Enter<br />
!<br />
ON<br />
Function ON<br />
www.phoenixcontact.com<br />
N+1 ECO<br />
UPS compact – 6000 VA Ord. –No.: 2800278<br />
1<br />
2<br />
ON<br />
OFF<br />
Enter<br />
!<br />
ON<br />
Function ON<br />
www.phoenixcontact.com<br />
N+1 ECO<br />
UPS compact – 6000 VA Ord. –No.: 2800278<br />
OFF<br />
Enter<br />
!<br />
ON<br />
Function ON<br />
www.phoenixcontact.com<br />
USV<br />
Bypass<br />
INPUT<br />
OUTPUT<br />
Parallel or redundant mode<br />
Using the particular functional units with 4.5 and 6 kVA as a basis,<br />
the parallel units allow additional functional units of the same performance<br />
class to be added.<br />
Redundancy mode 1 + 1:<br />
Parallel unit for two UPSs<br />
Redundancy mode 2 + 1:<br />
Parallel unit for three UPSs<br />
UPS-CP-PU-240AC/32A-4.5/6KVA<br />
Order No. 2800297<br />
UPS-CP-PU-240AC/63A-4.5/6KVA<br />
Order No. 2800298<br />
Properties:<br />
Properties:<br />
• Nominal voltage: 240 V AC<br />
• Nominal current: 32 A<br />
• Weight: 7.1 kg<br />
• Dimensions: 88.89 x 482.6 x 280 mm<br />
RJ-45 kit<br />
• Nominal voltage: 240 V AC<br />
• Nominal current: 63 A<br />
• Weight: 7.1 kg<br />
• Dimensions: 88.89 x 482.6 x 280 mm<br />
RJ-45 kit<br />
Accessories (including):<br />
Accessories (including):<br />
• Communication cable RJ-45 kit<br />
- 2 x cable 1.1 m RJ-45<br />
• Installation material<br />
• Communication cable RJ-45 kit<br />
- 2 x cable 1.1 m RJ-45<br />
• Installation material<br />
IN<br />
OUT<br />
CAN Bus Loop<br />
(RJ-45)<br />
IN<br />
OUT<br />
CAN Bus Loop<br />
(RJ-45)<br />
Operating behavior with 32 A parallel unit<br />
Redundancy mode (1 + 1)<br />
4.5 kVA Operating load Functional behavior<br />
≤ 4.5 kVA 1 x 4.5 kVA + 1 x 4.5 kVA redundant<br />
≥ 4.5 kVA 1 x 9 kVA parallel (auto changeover)<br />
6 kVA Operating load Functional behavior<br />
≤ 6 kVA<br />
1 x 6 kVA + 1 x 6 kVA redundant<br />
≥ 6 kVA<br />
1 x 12 kVA parallel (auto changeover)<br />
Operating behavior with 63 A parallel unit<br />
Redundancy mode (2 + 1)<br />
4.5 kVA Operating load Functional behavior<br />
≤ 9 kVA 1 x 9 kVA [4.5 + 4.5] +<br />
1 x 4.5 kVA redundant<br />
6 kVA Operating load Functional behavior<br />
≤ 12 kVA 1 x 12 kVA [6 + 6] +<br />
1 x 6 kVA redundant<br />
PHOENIX CONTACT 15
Further information on the products<br />
presented here and on the world of solutions<br />
from <strong>Phoenix</strong> <strong>Contact</strong> can be found at<br />
www.phoenixcontact.net/catalog<br />
Modular Terminal Blocks<br />
CLIPLINE 1<br />
Marking Systems, Tools, and<br />
Mounting Material<br />
CLIPLINE 2<br />
Or contact us directly.<br />
Connection Technology for<br />
Field Devices and Field Cabling<br />
PLUSCON<br />
Device Connection Technology<br />
and Electronic Housings<br />
COMBICON<br />
PHOENIX CONTACT GmbH & Co. KG<br />
32823 Blomberg, Germany<br />
Phone: +49 (0) 52 35 3-00<br />
Fax: +49 (0) 52 35 3-4 12 00<br />
www.phoenixcontact.com<br />
Automation Components<br />
and Systems<br />
AUTOMATION<br />
<strong>Power</strong> and Signal Quality<br />
TRABTECH<br />
Signal Converters, Switching Devices,<br />
<strong>Power</strong> Supply Units<br />
INTERFACE<br />
MNR 520056 5 2/15.03.2012-02 Printed in Germany © PHOENIX CONTACT 2012