<strong>Power</strong> <strong>Supplies</strong><br />

Uninterruptible power supply<br />

for AC grids


Interference-free mains supply<br />

and signal transmission<br />

A constant power supply is essential for the<br />

operational reliability of electrical systems,<br />

installations and devices.<br />

These requirements are satisfied by the<br />

class VFI-SS-111 single-phase power supply<br />

units. They are available as stand-alone<br />

device or for mounting in a 19“ rack.<br />

<strong>Phoenix</strong> <strong>Contact</strong> offers a compatible range of<br />

products for your power supply solution in the<br />

control cabinet. <strong>Power</strong> supply units, DC/DC<br />

converters and redundancy modules as well as<br />

uninterruptible power supply units for the control<br />

cabinet ensure maximum system availability.<br />

Further information can be obtained from the<br />

<strong>Power</strong> <strong>Supplies</strong> for Maximum System Availability<br />

brochure.<br />

2 PHOENIX CONTACT


Table of contents<br />

Constant power supply and<br />

improved power quality<br />

UPS compact: multifunctional<br />

for single-phase applications<br />

Page 4<br />

Page 6<br />

1 to 3 kVA<br />

Compact UPS solutions<br />

with 1 to 3 kVA power<br />

Page 8<br />

Accessories for UPS-CP devices<br />

with 1 to 3 kVA power<br />

Page 10<br />

4.5 to 6 kVA<br />

Redundant UPS solutions<br />

with 4.5 to 6 kVA power<br />

Page 12<br />

Accessories for UPS-CP devices<br />

with 4.5 to 6 kVA power<br />

Page 14<br />

Reliable protection against voltage interruptions<br />

Within power supply networks, even<br />

the slightest voltage fluctuations or<br />

power failures can cause significant<br />

disturbances in IT systems. Devices for<br />

uninterruptible power supply intercept<br />

these mains faults and ensure a constant<br />

supply voltage via battery support.<br />

Computer crashes, program errors<br />

or data loss are therefore effectively<br />

prevented.<br />

Loads are permanently supplied with an<br />

output voltage or output frequency that<br />

is independent of the mains input.<br />

43.8%<br />

Brief interruption – huge effect<br />

Recent VDE studies on quality of supply have shown that<br />

the risk of mains failures and brief interruptions is on the<br />

increase.* The average failure time per year increased from<br />

15 to 23 minutes.<br />

* Source: „Betriebsichere Rechenzentren – Leitfaden“, BITKOM<br />

Bundesverband Informationswirtschaft,Telekommunikation und neue Medien e.V.<br />

29.2%<br />

21.9%<br />

1.5%<br />

3.6%<br />

0–10 ms 10–20 ms 20 ms–1 s 1 s–1 h > 1 h<br />

PHOENIX CONTACT 3


Constant power supply<br />

and improved power quality<br />

UPS devices are an important measure<br />

for reliable power quality. They bridge<br />

current failures and eliminate other power<br />

malfunctions such as:<br />

• Undervoltages or surge voltages<br />

• High-frequency noises<br />

• Frequency fluctuations<br />

• Harmonics<br />

UPS devices for key areas of the company<br />

All devices of the UPS-CP series are VFI-SS-111-classified.<br />

They provide the right protective solution for all typical<br />

interferences and interruptions.<br />

The UPS classification code as per IEC 62040-3<br />

Output behavior in normal mode<br />

VFI (class 1):<br />

Voltage and Frequency Independent<br />

(Online)<br />

VI (class 2):<br />

Voltage Independent<br />

(Line-Interactive)<br />

VFD (Class 3):<br />

Voltage and Frequency Dependent<br />

(Offline)<br />

VFI SS 111<br />

Output behavior of the voltage curves 1)<br />

S = Sinusoidal voltage curve in the case of linear and non-linear load<br />

(values < IEC 61000-2-2; D < 0.08)<br />

X = Sinusoidal voltage curve for linear load (non-linear: D > 0.08)<br />

Y = Non-sinusoidal voltage curve (Values > IEC 61000-2-2)<br />

1)<br />

First position: Specification of normal mode<br />

Second position: Specification of battery mode<br />

Dynamics of the output behaviors 2)<br />

1 = Interruption-free<br />

2 = Voltage interruption < 1 ms<br />

3 = Voltage interruption < 10 ms<br />

4 = Individual as per the manufacturer<br />

2)<br />

First number: When changing the operating mode<br />

Second number: In the case of the maximum linear load jump<br />

Third number: In the case of the maximum non-linear load jump<br />

4 PHOENIX CONTACT


The top features of the UPS-CP series<br />

Long-life batteries<br />

The special regulating<br />

function for the charging<br />

of the UPS-CP devices<br />

ensures a ripple-free DC<br />

voltage without higher-level<br />

alternating currents.<br />

Integrated safety<br />

switch-off<br />

If required, the UPS-CP<br />

devices can be integrated<br />

into a safety concept via<br />

a two-pole connection.<br />

Simple battery<br />

replacement<br />

(Hot-Swap)<br />

A battery can be replaced<br />

without problems while the<br />

device is still installed. This<br />

applies to both UPS devices<br />

and battery modules.<br />

Choice of stand-alone<br />

or 19" rack use<br />

The operating panel of<br />

the UPS-CP devices can be<br />

rotated by 90° to ensure<br />

optimum legibility of the<br />

display for the particular<br />

application.<br />

UPS device classes and operating functions (IEC 62040-3)<br />

VFI (class 1 / Online)<br />

VI (class 2 / Line-Interactive)<br />

VFD (class 3 / Offline)<br />

Mains failure Voltage dips Voltage<br />

peaks<br />

Undervoltages<br />

Overvoltages<br />

Transient<br />

overvoltages<br />

Voltage<br />

surges<br />

Frequency<br />

fluctuations<br />

Voltage<br />

distortions<br />

Harmonics<br />

Duration of interference / characteristic<br />

> 10 ms > 10 ms > 10 ms Constant Constant<br />

Sporadic<br />

350 μs<br />

< 4 ms Sporadic Periodic Constant<br />

Additionally recommended solutions for surge protection (IEC 60364-5-534)<br />

Type 1<br />

Type 1/2<br />

Type 2<br />

Type 1<br />

Type 1/2<br />

We recommend the use of additional surge protection devices. For more information, visit www.phoenixcontact.com<br />

PHOENIX CONTACT 5


UPS compact: Multifunctional<br />

for single-phase applications<br />

The UPS devices of the UPS-CP series are<br />

suitable for a wide range of applications.<br />

The system can be configured as per the<br />

requirement and the operating environment.<br />

Other battery, bypass or parallel<br />

modules expand the application profile<br />

of the UPS-CP devices.<br />

*<br />

High system integration<br />

The driver and monitor software of the<br />

UPS-CP series supports the most common<br />

operating systems. The latest versions are<br />

available under: www.phoenixcontact.com<br />

* The logos depicted are international trademarks of<br />

their owners in their respective countries.<br />

MTTR – Bypass modules ensure minimum service times<br />

Mean time to recover – Minimum possible time is important for<br />

professional applications. The UPS-CP series fulfills this requirement<br />

completely with the separate bypass modules. In the 4.5 and 6 kVA<br />

performance class, even redundant or parallel operation of the<br />

devices is possible.<br />

Bypass module<br />

For the UPS-CP devices<br />

with 1 to 3 kVA power<br />

• Including connection and<br />

distributor cables:<br />

- 1 x IEC C19 on C20<br />

- 1 x IEC C20 on C13<br />

- 1 x IEC C19 on C14<br />

• Including installation material<br />

See page 10<br />

Bypass module<br />

For the UPS-CP devices<br />

with 4.5 to 6 kVA power<br />

• Including installation material<br />

See page 13<br />

Parallel unit<br />

For the UPS-CP devices<br />

with 4.5 to 6 kVA power<br />

• Parallel or redundant<br />

operation of two UPS<br />

devices (1+1 switching)<br />

• With bypass function<br />

• Including installation material<br />

See page 15<br />

Parallel unit<br />

For the UPS-CP devices<br />

with 4.5 to 6 kVA power<br />

• Parallel or redundant<br />

operation of three UPS<br />

devices (2+1 switching)<br />

• With bypass function<br />

• Including installation material<br />

See page 15<br />

6 PHOENIX CONTACT


INPUT<br />

BREAKER<br />

AC INPUT<br />

AC OUTPUT<br />

INPUT<br />

BREAKER<br />

AC INPUT<br />

INPUT<br />

BREAKER<br />

AC INPUT<br />

Wide-reaching configuration using hardware or software<br />

The UPS-CP devices can be directly configured via<br />

the operating panel and in the case of charged batteries<br />

even without external power connection.<br />

The illuminated and easily legible LCD operating<br />

panel provides information about important status<br />

parameters such as the charging status or the<br />

supply voltage. The additional software also enables<br />

controlled shutdown of a computer via a program<br />

command.<br />

The optional SNMP extension cards can be used<br />

for comprehensive administration of the<br />

UPS-CP devices through the grid. Access is simply<br />

via the web browser, where logs can be called up<br />

or planned actions programmed.<br />

The current software versions are available in the<br />

E-shop of <strong>Phoenix</strong> <strong>Contact</strong> for download.<br />

LED for quick status check<br />

Illuminated LCD operating panel<br />

Large function keys<br />

Operating panel of<br />

1 to 3 kVA devices<br />

Operating panel of<br />

4.5 to 6 kVA devices<br />

Expandable communication interfaces<br />

In addition to the existing interfaces such as the RS-232 or USB connection,<br />

all UPS-CP devices can be expanded with the SNMP/MODBUS network cards.<br />

AC OUTPUT<br />

AC OUTPUT<br />

INTERFAC<br />

E<br />

INTERFAC<br />

E<br />

INTERFAC<br />

E<br />

Network card<br />

UPS-SNMP-CARD<br />

Order No. 2800289<br />

• ETHERNET 10/100 Mbit Base-T<br />

(Auto-Sense)<br />

• Status LED<br />

Network card<br />

UPS-SNMP-CARD E<br />

Order No. 2800290<br />

• ETHERNET 10/100 Mbit Base-T<br />

(Auto-Sense)<br />

• MODBUS<br />

• AUX<br />

• D-SUB adapter cable<br />

• Status LED<br />

Relay card<br />

UPS-6REL<br />

Order No. 2800287<br />

Floating switching contacts for status<br />

messages through:<br />

• Bypass mode / Voltage supply / Inverter<br />

mode / Battery voltage / Battery status /<br />

Common alarm<br />

• Switching contacts for safety shutdown<br />

PHOENIX CONTACT 7


IN 1 2 BY<br />

UPS compact – 1000 VA Ord. –No.: 2800274<br />

ON<br />

OFF<br />

Enter<br />

Function<br />

!<br />

ON<br />

ON<br />

www.phoenixcontact.com<br />

IN 1 2 BY<br />

!<br />

IN 1 2 BY<br />

UPS compact – 1000 VA Ord. –No.: 2800274<br />

ON<br />

OFF<br />

ON<br />

OFF<br />

ON<br />

Enter<br />

Function<br />

!<br />

ON<br />

ON<br />

ON<br />

www.phoenixcontact.com<br />

Compact UPS solutions<br />

with 1 to 3 kVA power<br />

UPS compact – 1000 VA Ord. –No.: 2800274<br />

Enter<br />

Function<br />

www.phoenixcontact.com<br />

The UPS-CP devices with 1 to 3 kVA<br />

power are complete UPS solutions with<br />

control unit and batteries integrated in<br />

one housing.<br />

Additional battery modules extend the<br />

bridging times.<br />

The UPS devices and battery modules<br />

are delivered along with all the necessary<br />

connecting cables and installation materials.<br />

Thanks to the supplied installation<br />

materials and the rotatable<br />

display, the UPS devices can be<br />

used as 19" rack modules or as<br />

floor-mounted devices.<br />

UPS<br />

UPS-CP with 1 to 3 kVA<br />

General features:<br />

• 1 to 2 kVA: 6 x 10 A IEC outputs<br />

• 3 kVA: 1 x 16 A, 4 x 10 A IEC outputs<br />

• Two 10 A IEC outputs that can be switched<br />

via a software command<br />

• Complete solutions with internal batteries<br />

• Can be combined with external bypass<br />

modules and sockets<br />

• Serial USB and RS-232 interface<br />

Technical data:<br />

• VFI-SS-111 classified<br />

• <strong>Power</strong> factor: 0.8<br />

• Input: 160 ... 288 V AC (50/60 Hz)<br />

• Output (adjustable):<br />

200/208/220/230/240V AC (50/60 Hz)<br />

• Switch-over time: 0 ms<br />

• Crest factor: 3:1<br />

Time (min)<br />

1 kVA UPS-CP-1KVA/240AC<br />

Order No. 2800274<br />

UPS with 3 internal batteries<br />

P1<br />

without additional battery<br />

1 x P1<br />

2 x P1 or 1 x P2<br />

UPS-CP-BAT-1KVA-P1<br />

Order No. 2800280<br />

Battery module with 2 x 3 batteries<br />

Nominal real power (W)*<br />

P2<br />

UPS-CP-BAT-1KVA-P2<br />

Order No. 2800281<br />

Battery module with 4 x 3 batteries<br />

* Real power = Apparent power x <strong>Power</strong> factor<br />

8 PHOENIX CONTACT


EPO<br />

EPO<br />

EPO<br />

G<br />

DC 36V<br />

AC INPUT<br />

INPUT<br />

BREAKER<br />

G<br />

DC 72V<br />

G<br />

DC 72V<br />

1 2<br />

INPUT<br />

BREAKER<br />

1 2<br />

INPUT<br />

BREAKER<br />

INPUT<br />

BREAKER<br />

INPUT<br />

BREAKER<br />

INPUT<br />

BREAKER<br />

1<br />

AC OUTPUT<br />

2<br />

AC INPUT<br />

AC INPUT<br />

Switchable supply connections<br />

1 kVAG<br />

2 kVA<br />

INTERFACE E<br />

AC OUTPUT<br />

INTERFACE E<br />

In the case of UPS devices with<br />

1 to 3 kVA, two outputs each can<br />

be switched without voltage via<br />

a software command.<br />

In critical situations, the energy<br />

saved at these outputs is available<br />

for the more important devices.<br />

3 kVA<br />

AC OUTPUT<br />

INTERFACE E<br />

Battery<br />

The maximum expected bridging time of a UPS-CP device<br />

depends on the connected payload.<br />

Depending on the type and number of additional battery<br />

modules, refer to the diagrams for the corresponding longer<br />

bridging times.<br />

Time (min)<br />

Time (min)<br />

without additional battery<br />

Nominal real power (W)*<br />

1 x P3 3 x P3<br />

2 x P3 or 1 x P4 4 x P3 or 2 x P4<br />

without additional battery<br />

Nominal real power (W)*<br />

1 x P3 3 x P3<br />

2 x P3 or 1 x P4 4 x P3 or 2 x P4<br />

2 kVA UPS-CP-2KVA/240AC<br />

Order No. 2800275<br />

UPS with 6 internal batteries<br />

3 kVA UPS-CP-3KVA/240AC<br />

Order No. 2800276<br />

UPS with 6 internal batteries<br />

P3<br />

UPS-CP-BAT-2/3KVA-P3<br />

Order No. 2800283<br />

P3<br />

UPS-CP-BAT-2/3KVA-P3<br />

Order No. 2800283<br />

Battery module with 6 batteries<br />

Battery module with 6 batteries<br />

P4<br />

UPS-CP-BAT-2/3KVA-P4<br />

Order No. 2800284<br />

P4<br />

UPS-CP-BAT-2/3KVA-P4<br />

Order No. 2800284<br />

Battery module with 2 x 6 batteries<br />

Battery module with 2 x 6 batteries<br />

PHOENIX CONTACT 9


Accessories for UPS-CP devices<br />

with 1 to 3 kVA power<br />

In addition to the general expansion<br />

options such as SNMP or relay cards,<br />

more accessories are also available for the<br />

UPS-CP devices with 1 to 3 kVA power.<br />

All bypass modules and sockets are delivered along<br />

with the fastening material for rack mounting.<br />

The UPS system can be added and<br />

expanded to match the prevailing<br />

conditions.<br />

C20<br />

C19<br />

C20<br />

C13<br />

C14<br />

C19<br />

DIN rail 19’’<br />

Bypass for 1 to 3 kVA UPS<br />

UPS-CP-19’’MR<br />

Order No. 2800288<br />

When planning a rack, the weight of the individual devices is an<br />

important aspect. The rails support the heavy UPS devices and<br />

battery modules. These accessories are indispensable for a stable<br />

and safe rack.<br />

Properties:<br />

• Max. carrying capacity: 50 kg per rail (total 100 kg)<br />

• Dimensions: 520 x 50 x 90 mm<br />

• Individual extension length: 520 – 880 mm<br />

• Weight: 2.6 kg<br />

UPS-CP-BP-1/2/3KVA<br />

Order No. 2800291<br />

The external bypass module reduces the service times<br />

considerably since it allows a quick change of a complete<br />

UPS housing without intervention into the installation.<br />

Properties:<br />

• Nominal voltage: 240 V AC<br />

OUTPUT<br />

BREAKER<br />

PUSH TO RESET<br />

• Nominal current: 16 A<br />

• Inputs: 1 x IEC connector C20<br />

• Outputs: 6 x socket C13, 1 x socket C19<br />

• Weight: 3.8 kg<br />

• Dimensions: 88.89 x 482.6 OUTPUT 10A x MA.X 120 mm<br />

Accessories (including):<br />

• 1 x adapter cables (1.8 m)<br />

Connector C20 Socket C19<br />

• 1 x adapter cables (1.8 m)<br />

Connector C20 Socket C13<br />

• 1 x adapter cables (1.8 m)<br />

Connector C14 Socket OUTPUT 10A C19 MA.X<br />

• Installation material<br />

OUTPUT<br />

BREAKER<br />

PUSH TO RESET<br />

TO UPS OUTPUT T<br />

TO UPS OUTPUT T<br />

UPS<br />

AVAILABLE<br />

UPS<br />

UPS active<br />

UPS<br />

AVAILABLE<br />

UPS<br />

MAINTANANCE<br />

AVAILABLE<br />

UTILITY<br />

MAINTANANCE<br />

AVAILABLE<br />

<strong>Power</strong> supply<br />

active<br />

UTILITY<br />

BYPASS<br />

BYPASS<br />

UTILITY<br />

UTILITY<br />

10 PHOENIX CONTACT


AC INTPUT<br />

AC OUTPUT<br />

Easy replacement of the internal batteries<br />

In the case of the UPS-CP devices and the battery modules,<br />

the internal battery blocks can be replaced easily.<br />

Thanks to the hot-swap technology, replacement is possible<br />

during operation and with the device still installed.<br />

C14 C19 C14 C13<br />

C20<br />

C19<br />

Socket strip 9 x 10 A<br />

UPS-CP-MS-9x10A-IEC<br />

Order No. 2800293<br />

Multiple socket strip with 3 x 3 IEC 60320 C13 sockets.<br />

Every group of three is separately fused with 10 A.<br />

Socket strip 4 x 16 A<br />

UPS-CP-MS-4x16A-IEC<br />

Order No. 2800294<br />

Multiple socket with four IEC 60320<br />

C19 outputs sockets.<br />

Properties:<br />

• Nominal voltage: 240 V AC<br />

• Nominal current: OUTPUT 16 A (input) / 10 A (output)<br />

BREAKER<br />

PUSH TO RESET<br />

• Input: 1 x IEC connector C20<br />

• Output: 9 x IEC socket C13<br />

• Weight: 1.8 kg<br />

• Dimensions: 44.45 x 482.6 x 90 mm<br />

CONNECT UPS<br />

LINE CORD HERE<br />

CONNECT UPS<br />

LINE CORD HERE<br />

OUTPUT 16A MAX.<br />

OUTPUT 10A MAX.<br />

Accessories (including):<br />

• 1 x adapter cables (1.8 m)<br />

Connector C14 OUTPUT Socket C19<br />

BREAKER<br />

PUSH TO RESET<br />

• 5 x adapter cables (1.8 m)<br />

Connector C14 Socket C13<br />

• Installation material<br />

BREAKER<br />

Properties:<br />

• Nominal voltage: 240 V AC<br />

• Nominal current: 16 A (input/output)<br />

• Input: 1 x IEC connector C20<br />

• Output: 4 x IEC socket C19<br />

• Weight: 1.8 kg<br />

• Dimensions: 44.45 x 482.6 x 90 mm<br />

Accessories (including):<br />

• 6 x adapter cables (1.8 m)<br />

Connector C20 Socket C19<br />

• Installation material<br />

BREAKER<br />

OUTPUT 16A MAX.<br />

OUTPUT 10A MAX.<br />

10A<br />

10A<br />

AC INTPUT<br />

AC OUTPUT<br />

10 A fuse<br />

Assembly variants<br />

PHOENIX CONTACT 11


Redundant UPS solutions<br />

with 4.5 to 6 kVA power<br />

If you need more power, the UPS-CP<br />

devices with 4.5 or 6 kVA provide<br />

the correct solution. Devices of this<br />

performance class can also be operated<br />

parallelly or redundantly and thus ensure<br />

additional performance reserves and<br />

increased availability. A functional unit<br />

always consists of a UPS device and a<br />

separate battery module.<br />

UPS<br />

Battery<br />

4,5 kVA<br />

UPS-CP with 4.5 to 6 kVA<br />

General features:<br />

• Pluggable input/output connections<br />

• <strong>Power</strong> up to 12 kVA (parallel mode)<br />

• Parallel/redundancy mode<br />

(Communication via CAN Bus interfaces)<br />

• Can be combined with external bypass modules<br />

and sockets<br />

• Serial RS-232 interface<br />

• All required connecting cables are supplied<br />

with the devices<br />

Technical data:<br />

• VFI-SS-111 classified<br />

• <strong>Power</strong> factor: 0.7<br />

• Input: 160 ... 280 V AC (50/60 Hz)<br />

• Output (adjustable):<br />

200/208/220/230/240V AC (50/60 Hz)<br />

• Switch-over time: 0 ms<br />

• Crest factor: 3:1<br />

Time (min)<br />

1 x P5<br />

2 x P5 4 x P5<br />

3 x P5 5 x P5<br />

4,5 kVA UPS-CP-4.5KVA/240AC<br />

Order No. 2800277<br />

UPS<br />

P5<br />

UPS-CP-BAT-4.5/6KVA-P5<br />

Order No. 2800285<br />

Battery module with 20 batteries<br />

Nominal real power (W)*<br />

The maximum expected bridging time of a UPS-CP device<br />

depends on the connected payload. Depending on the type<br />

* Real power = Apparent power x <strong>Power</strong> factor<br />

12 PHOENIX CONTACT


1<br />

2<br />

N+1 ECO<br />

UPS compact – 4500 VA Ord. –No.: 2800277<br />

ON<br />

OFF<br />

Enter<br />

!<br />

ON<br />

Function ON<br />

www.phoenixcontact.com<br />

1<br />

2<br />

ON<br />

N+1 ECO<br />

UPS compact – 6000 VA Ord. –No.: 2800278<br />

OFF<br />

Enter<br />

!<br />

ON<br />

Function ON<br />

www.phoenixcontact.com<br />

USV<br />

Bypass<br />

INPUT<br />

OUTPUT<br />

Short service times when using the bypass module<br />

Due to high current outputs, the 4.5 and<br />

6 kVA UPS devices are connected directly<br />

to the fixed installation.<br />

IN<br />

OUT<br />

IN<br />

OUT<br />

Basic structure<br />

4.5 and 6 kVA UPS configurations always<br />

consist of a UPS device and a battery<br />

module. If they are operated via the standard<br />

connecting cable, the connected system must<br />

always be switched off too for replacement.<br />

Basic structure + Bypass module<br />

The bypass module can be used instead of<br />

the provided connecting cable. If servicing<br />

is necessary, a fast replacement of the UPS<br />

system is possible without having to switch<br />

off the system.<br />

UPS<br />

Battery<br />

6 kVA<br />

Time (min)<br />

External bypass module<br />

UPS-CP-BP-4.5/6KVA<br />

Order No. 2800292<br />

A bypass module is always suitable for a functional unit comprising<br />

a UPS device (4.5/6 kVA) and a battery module.<br />

1 x P5<br />

2 x P5 4 x P5<br />

3 x P5 5 x P5<br />

6 kVA UPS-CP-6KVA/240AC<br />

Order No. 2800278<br />

UPS<br />

Nominal real power (W)*<br />

Properties:<br />

• Nominal voltage: 240 V AC<br />

• Nominal current: 32 A<br />

• Weight: 6.3 kg<br />

• Dimensions: 88.89 x 482.6 x 280 mm<br />

Accessories (including):<br />

• Installation material<br />

P5<br />

UPS-CP-BAT-4.5/6KVA-P5<br />

Order No. 2800285<br />

Battery module with 20 batteries<br />

and number of additional battery modules, refer to the<br />

diagrams for the corresponding longer bridging times.<br />

PHOENIX CONTACT 13


Accessories for UPS-CP devices<br />

with 4.5 to 6 kVA power<br />

The devices of the 4.5 and 6 kVA<br />

performance class have been especially<br />

designed for parallel and redundant<br />

use. Depending on the basic device,<br />

configurations with 9 or 12 kVA are<br />

possible.<br />

C14 C13 C20 C19<br />

DIN rail 19’’<br />

19’’ Multiple socket strip<br />

UPS-CP-19’’MR<br />

Order No. 2800288<br />

When planning a rack, the weight of the individual devices is an<br />

important aspect. The rails help support the heavy UPS devices<br />

and battery modules. These accessories are indispensable for a<br />

stable and safe rack.<br />

Properties:<br />

• Max. carrying capacity: 50 kg per rail (total 100 kg)<br />

• Dimensions: 520 x 50 x 90 mm<br />

• Individual extension length: 520 BREAKER – 880 mm<br />

• Weight: 2.6 kg<br />

UPS-CP-MS-5x16A/9x10A-IEC<br />

Order No. 2800296<br />

This multiple socket strip has five separately secured C19 sockets<br />

and three secured three groups with C13 sockets.<br />

Properties:<br />

Nominal voltage: 240 V AC<br />

Nominal current: 16 A (input/output)<br />

Input: 1 x IEC connector C20<br />

Output: 4 x IEC socket C19<br />

BREAKER<br />

Weight: 1.8 kg<br />

Dimensions: 44.45 x 482.6 x 90 mm<br />

10 A fuse<br />

BREAKER<br />

AC OUTPUT<br />

BREAKER<br />

BREAKER<br />

16A<br />

BREAKER<br />

10A<br />

10A<br />

BREAKER<br />

BREAKER<br />

16A<br />

BREAKER<br />

16A<br />

BREAKER<br />

10A<br />

Accessories (including):<br />

• 6 x adapter cables (1.8 m)<br />

Connector C14 Socket C13<br />

10A<br />

BREAKER<br />

BREAKER<br />

• 5 x adapter cables (1.8 m)<br />

Connector C20<br />

• Installation material<br />

Socket C19<br />

BREAKER<br />

16A<br />

16 A fuse<br />

BREAKER<br />

10A<br />

10A<br />

BREAKER<br />

BREAKER<br />

16A<br />

AC OUTPUT<br />

16A<br />

16A<br />

16A<br />

16A<br />

16A<br />

14 PHOENIX CONTACT


1<br />

2<br />

ON<br />

N+1 ECO<br />

UPS compact – 4500 VA Ord. –No.: 2800277<br />

1<br />

2<br />

ON<br />

OFF<br />

Enter<br />

!<br />

ON<br />

Function ON<br />

www.phoenixcontact.com<br />

N+1 ECO<br />

UPS compact – 4500 VA Ord. –No.: 2800277<br />

OFF<br />

Enter<br />

!<br />

ON<br />

Function ON<br />

www.phoenixcontact.com<br />

USV<br />

Bypass<br />

INPUT<br />

OUTPUT<br />

1<br />

2<br />

ON<br />

N+1 ECO<br />

UPS compact – 6000 VA Ord. –No.: 2800278<br />

1<br />

2<br />

ON<br />

OFF<br />

Enter<br />

!<br />

ON<br />

Function ON<br />

www.phoenixcontact.com<br />

N+1 ECO<br />

UPS compact – 6000 VA Ord. –No.: 2800278<br />

1<br />

2<br />

ON<br />

OFF<br />

Enter<br />

!<br />

ON<br />

Function ON<br />

www.phoenixcontact.com<br />

N+1 ECO<br />

UPS compact – 6000 VA Ord. –No.: 2800278<br />

OFF<br />

Enter<br />

!<br />

ON<br />

Function ON<br />

www.phoenixcontact.com<br />

USV<br />

Bypass<br />

INPUT<br />

OUTPUT<br />

Parallel or redundant mode<br />

Using the particular functional units with 4.5 and 6 kVA as a basis,<br />

the parallel units allow additional functional units of the same performance<br />

class to be added.<br />

Redundancy mode 1 + 1:<br />

Parallel unit for two UPSs<br />

Redundancy mode 2 + 1:<br />

Parallel unit for three UPSs<br />

UPS-CP-PU-240AC/32A-4.5/6KVA<br />

Order No. 2800297<br />

UPS-CP-PU-240AC/63A-4.5/6KVA<br />

Order No. 2800298<br />

Properties:<br />

Properties:<br />

• Nominal voltage: 240 V AC<br />

• Nominal current: 32 A<br />

• Weight: 7.1 kg<br />

• Dimensions: 88.89 x 482.6 x 280 mm<br />

RJ-45 kit<br />

• Nominal voltage: 240 V AC<br />

• Nominal current: 63 A<br />

• Weight: 7.1 kg<br />

• Dimensions: 88.89 x 482.6 x 280 mm<br />

RJ-45 kit<br />

Accessories (including):<br />

Accessories (including):<br />

• Communication cable RJ-45 kit<br />

- 2 x cable 1.1 m RJ-45<br />

• Installation material<br />

• Communication cable RJ-45 kit<br />

- 2 x cable 1.1 m RJ-45<br />

• Installation material<br />

IN<br />

OUT<br />

CAN Bus Loop<br />

(RJ-45)<br />

IN<br />

OUT<br />

CAN Bus Loop<br />

(RJ-45)<br />

Operating behavior with 32 A parallel unit<br />

Redundancy mode (1 + 1)<br />

4.5 kVA Operating load Functional behavior<br />

≤ 4.5 kVA 1 x 4.5 kVA + 1 x 4.5 kVA redundant<br />

≥ 4.5 kVA 1 x 9 kVA parallel (auto changeover)<br />

6 kVA Operating load Functional behavior<br />

≤ 6 kVA<br />

1 x 6 kVA + 1 x 6 kVA redundant<br />

≥ 6 kVA<br />

1 x 12 kVA parallel (auto changeover)<br />

Operating behavior with 63 A parallel unit<br />

Redundancy mode (2 + 1)<br />

4.5 kVA Operating load Functional behavior<br />

≤ 9 kVA 1 x 9 kVA [4.5 + 4.5] +<br />

1 x 4.5 kVA redundant<br />

6 kVA Operating load Functional behavior<br />

≤ 12 kVA 1 x 12 kVA [6 + 6] +<br />

1 x 6 kVA redundant<br />

PHOENIX CONTACT 15


Further information on the products<br />

presented here and on the world of solutions<br />

from <strong>Phoenix</strong> <strong>Contact</strong> can be found at<br />

www.phoenixcontact.net/catalog<br />

Modular Terminal Blocks<br />

CLIPLINE 1<br />

Marking Systems, Tools, and<br />

Mounting Material<br />

CLIPLINE 2<br />

Or contact us directly.<br />

Connection Technology for<br />

Field Devices and Field Cabling<br />

PLUSCON<br />

Device Connection Technology<br />

and Electronic Housings<br />

COMBICON<br />

PHOENIX CONTACT GmbH & Co. KG<br />

32823 Blomberg, Germany<br />

Phone: +49 (0) 52 35 3-00<br />

Fax: +49 (0) 52 35 3-4 12 00<br />

www.phoenixcontact.com<br />

Automation Components<br />

and Systems<br />

AUTOMATION<br />

<strong>Power</strong> and Signal Quality<br />

TRABTECH<br />

Signal Converters, Switching Devices,<br />

<strong>Power</strong> Supply Units<br />

INTERFACE<br />

MNR 520056 5 2/15.03.2012-02 Printed in Germany © PHOENIX CONTACT 2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!