2-4<br />

Table 2 - 1 RAID Levels<br />

RAID Level Description Capacity Data Availability<br />

NRAID Non-RAID N N/A<br />

RAID 0 Disk Striping N ==NRAID<br />

RAID 1 (0+1) Mirroring Plus Striping (if N>1) N/2 >>NRAID<br />

==RAID 5<br />

RAID 3 Striping with Parity on<br />

N-1 >>NRAID<br />

dedicated disk<br />

==RAID 5<br />

RAID 5 Striping with interspersed N-1 >>NRAID<br />

parity<br />

==RAID 5<br />

Logical<br />

Volume<br />

Striping one or more logical<br />

drives of different RAID levels<br />

* Higher; depends<br />

on its members<br />

RAID Level Performance Sequential Performance Random<br />

NRAID Drive Drive<br />

RAID 0 R: Highest<br />

R: High<br />

W: Highest<br />

W: Highest<br />

RAID 1 (0+1) R: High<br />

R: Medium<br />

W: Medium<br />

W: Low<br />

RAID 3 R: High<br />

R: Medium<br />

W: Medium<br />

W: Low<br />

RAID 5 R: High<br />

R: High<br />

W: Medium<br />

W: Low<br />

Logical Volume Depends on its members;<br />

see above<br />

Depends on its members<br />

8. Any spare drives?<br />

(Swap Drive Rebuild / Spare Drive Rebuild)<br />

Spare drives allow for the unattended rebuilding of a failed<br />

drive, heightening the degree of fault tolerance. If there is no<br />

spare drive, data rebuild has to be manually initiated by<br />

replacing a failed drive with a healthy one.<br />

As is often ignored, a spare drive (whether dedicated or global)<br />

must have a capacity no smaller than the members of a logical<br />

drive.<br />

9. Limitations?<br />

Firmware 3.31 and above support 64-bit LBA. A maximum of<br />

64TB capacity can be included in single logical drive.<br />

Up to 128 members can be included in each logical drive.<br />

Extreme array sizes can cause operational problems with<br />

system backup and should be avoided.<br />

<strong>Infortrend</strong>