SOUTHWESTERN REGION<br />

John Farmer<br />

Discusses<br />

Installation and<br />

Internals<br />

Laurie Hanley<br />

TGI Friday's, Inc.<br />

The August 5th Southwest Region<br />

Users' Group meeting was called to<br />

order by Kerrie Meyler, <strong>the</strong> Southwest<br />

Regional Representative. The<br />

following orders of business were<br />

covered:<br />

1. General Business<br />

2. ADABAS 5 by John Farmer,<br />

<strong>Software</strong> AG<br />

3. PREDICT V2.3 discussion by<br />

Randy Kastendick, <strong>Software</strong> AG<br />

4. NATURAL 2 DESIGN discussion<br />

by John Wheat, University of<br />

Texas at Austin<br />

5. Round Tablelopen Forum<br />

General Business<br />

Several persons have asked how to<br />

receive <strong>the</strong> minutes and agenda<br />

from <strong>the</strong> Regional meetings. All<br />

minutes and meeting information<br />

are distributed through <strong>the</strong> Regional<br />

office. If you are not receiving<br />

this information, you should<br />

contact your Regional office: specifically<br />

Jon Hoaldridge in Dallas or<br />

Doug Roberts in Houston. In many<br />

cases only one copy of <strong>the</strong> information<br />

is sent to each user site. Often<br />

this may be sent to <strong>the</strong> wrong person<br />

who is not forwarding <strong>the</strong> information<br />

or distributing to <strong>the</strong><br />

proper personnel. If you are not receiving<br />

<strong>the</strong> information, you should<br />

contact Jon or Doug and confirm<br />

your distribution information.<br />

If you wish to obtain a copy of <strong>the</strong><br />

minutes from o<strong>the</strong>r Regions, you<br />

may contact John Oborn, <strong>the</strong> new<br />

Regional Representative.<br />

There is a new newsletter titled<br />

VVAN (VAX-VMS-ADABAS-<br />

NATURAL) which is being distributed<br />

among <strong>the</strong> DECIVAX users. If<br />

you have not received a copy of this<br />

newsletter and are interested in<br />

being on <strong>the</strong> mailing list please<br />

contact Kerrie Meyler or John<br />

Oborn.<br />

Elections for Southwest Region officers<br />

were held at this meeting!<br />

The new elected officers are:<br />

PresidentlRegional Rep.<br />

John Oborn<br />

Vice PresidentlPgm Coord.<br />

John Baird<br />

ADABAS 5<br />

John Farmer, <strong>Software</strong> AG, discussed<br />

ADABAS 5 installation and<br />

internals. He brought forward several<br />

very important points to note:<br />

The ADABAS 5 Internals Manual<br />

can only be obtained by attending<br />

<strong>the</strong> <strong>Software</strong> AG Internals<br />

course.<br />

You can convert from V4 to V5<br />

without unloading files.<br />

When installing ADABAS 5, you<br />

may perform a temporary or a<br />

permanent install of <strong>the</strong> SVC.<br />

When installing a temporary SVC<br />

you are not required to IPL.<br />

NOTE: The temporary SVC install<br />

is not possible for DOSIVSE<br />

users.<br />

AMODEIRMODE parameters are<br />

only required for MVSlXA shops.<br />

ADARUN is not upward compatible;<br />

you must have a V5<br />

ADARUN module to execute<br />

ADABAS 5.<br />

ADALNK is upward compatible;<br />

<strong>the</strong> TP links are NOT.<br />

ADASIP <strong>the</strong> (SVC Install Program)<br />

must be executed after<br />

each system IPL.<br />

ADASVC is loaded into and executed<br />

within <strong>the</strong> CSA.<br />

You cannot use 1'4 PLOG files<br />

with V5 nucleus; <strong>the</strong> checkpoint<br />

files are different.<br />

The BLKSIZE is larger on V5 for<br />

3380 devices; you must change<br />

your WORK dataset.<br />

You should alter <strong>the</strong> GCB entry<br />

for <strong>the</strong> number of blocks on <strong>the</strong><br />

WORK dataset before <strong>the</strong> V5 nucleus<br />

is initiated. This is discussed<br />

in both <strong>the</strong> Implementation<br />

Manual and <strong>the</strong> Users Guide.<br />

Also, when ADAWS NEW-<br />

WORK is run to alter <strong>the</strong> WORK<br />

dataset size in <strong>the</strong> GCB it only alters<br />

<strong>the</strong> GCB it does not alter <strong>the</strong><br />

actual size of <strong>the</strong> WORK dataset.<br />

Any user exits will have to be<br />

modified for V5.<br />

If you revert back to V4 from V5,<br />

you must first remove any<br />

HYPER Descriptors.<br />

The ADABAS 5 nucleus has been<br />

modified so that no user may<br />

take up more than 25% of <strong>the</strong><br />

hold queue; if a user attempts to<br />

place a number of records in <strong>the</strong><br />

queue larger than <strong>the</strong> maximum<br />

number of records setting, <strong>the</strong>y<br />

will receive a non-zero response<br />

code.<br />

The ADARUN parameter PLOG<br />

RQ=NO is <strong>the</strong> default parameter<br />

for <strong>the</strong> PLOG. This specifies that<br />

<strong>the</strong> MPM will come up with a<br />

PLOG as <strong>the</strong> default.<br />

The ADARUN parameter<br />

"UTIONLY" specifies that <strong>the</strong><br />

nucleus is brought up only in<br />

utility mode, users may not log<br />

on. The "UTIONLY =NO"<br />

parameter will return <strong>the</strong> MPM to<br />

use by users.<br />

ADABAS 5 will reformat a part of<br />

a RABN.<br />

When you delete a file in<br />

ADABAS 5, you may keep <strong>the</strong><br />

FDT entry. When you reload <strong>the</strong><br />

file, you may point to <strong>the</strong> FDT<br />

entry and specify <strong>the</strong> cards<br />

without having to recreate <strong>the</strong>m.<br />

You may now set a minimum ISN<br />

# to save address converter<br />

space.<br />

The DSTAT operator console<br />

command will display <strong>the</strong><br />

activity of a utility.<br />

Several processing statistics such<br />

as <strong>the</strong> number of blocks used on<br />

a SORT, etc. will be printed along<br />

with <strong>the</strong> ADALOD utility output.<br />

If you receive an error 10 when<br />

running a utility, it will tell you<br />

what DIB entry was in conflict.<br />

The ADASAV drive parameter<br />

can use up to 8 tape drives at one<br />

time. This will allow parallel<br />

activity to multiple drives to<br />

speed up backup and restore<br />

times.<br />

With ADARES BACKOUT, in V4,<br />

when it got to <strong>the</strong> end of tape 1 it<br />

would back out <strong>the</strong> end if you<br />

were not at ET status. Thus you<br />

could loose <strong>the</strong> end of one tape<br />

and <strong>the</strong> beginning of <strong>the</strong> next. In<br />

V5 you may specify no backout<br />

to prevent this from happening.