28.12.2014 Views

Magnetic flowmeters M910 / M910E / M920 - meatest.cz

Magnetic flowmeters M910 / M910E / M920 - meatest.cz

Magnetic flowmeters M910 / M910E / M920 - meatest.cz

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Image sheet<br />

<strong>Magnetic</strong> <strong>flowmeters</strong><br />

<strong>M910</strong> / <strong>M910</strong>E / <strong>M920</strong>


Sensor selection<br />

Compact<br />

low cost version<br />

• DN10 … DN800<br />

• PN10 … PN40<br />

• protection IP67<br />

• liner:<br />

hard rubber, PTFE<br />

• electrodes:<br />

stainless steel, hastelloy, tantalum, titanium<br />

• connection:<br />

DIN, ANSI, sanitary (DIN 11851)<br />

Remote<br />

basic version<br />

• DN10 … DN800<br />

• PN10 … PN40<br />

• sensor and convertor connected by cable<br />

• maximum length 60m<br />

• sensor protection IP68<br />

• convertor protection IP67<br />

• liner:<br />

hard rubber, PTFE<br />

• electrodes:<br />

stainless steel, hastelloy, tantalum, titanium<br />

• connection:<br />

DIN, ANSI, sanitary (DIN 11851)<br />

Remote Ex<br />

EX proof version<br />

• for applications with explosive atmosphere<br />

• 3G Ex nA T5 II<br />

• PN10 … PN25<br />

• other parameters as remote basic version


Converter selection<br />

<strong>M910</strong><br />

<strong>M910</strong>E<br />

basic version<br />

• pipe and electronic selfdiagnostic<br />

• programmable outputs:<br />

4-20mA, frequency, pulse, state<br />

• programmable input<br />

• datalogger, RTC<br />

• touch-less magnetic pointer<br />

• keyboard<br />

• protection IP67<br />

• RS232, RS485<br />

• accuracy 0.5%<br />

• power supply 115/230Vac, 12/24/48 Vdc<br />

low cost version<br />

• programmable outputs:<br />

4-20mA, frequency, pulse<br />

• touch-less magnetic pointer<br />

• protection IP67<br />

• RS232<br />

• accuracy 0.5%<br />

• power supply 115/230Vac, 12/24/48 Vdc<br />

<strong>M920</strong><br />

high accuracy version<br />

• empty pipe detection<br />

• temperature measurement<br />

• pipe and electronic selfdiagnostic<br />

• programmable outputs:<br />

4-20mA, frequency, pulse, state (alarm)<br />

• programmable input<br />

• datalogger, RTC<br />

• touch-less magnetic pointer<br />

• keyboard<br />

• protection IP67<br />

• RS232, RS485 modbus<br />

• accuracy 0.25%<br />

• power supply 85-264Vac, 12/24/48 Vdc


Diameter selection<br />

The choice of flow rate for an electromagnetic <strong>flowmeters</strong> depends on the diameter of the sensor. The<br />

higher pipe diameter, the higher flow rate can be measured. A determining parameter for flow rates is<br />

maximum velocity of the liquid. Maximum velocity is the speed, where the flow of liquid inside pipe is still<br />

laminar. In <strong>M910</strong> it is limited to 10m/s (with 125% overload). Speed over 10 m/s is usually too high for<br />

industrial applications. Such diameter of pipe is usually selected, where expected flow rate is between<br />

Q 5% and Q 50% .<br />

In the table bellow applicable flow rates for various diameters is displayed in l/s and m 3 /hr.<br />

Flow rates [ l/s ] Flow rates [ m3/h ]<br />

DN Q 0.3% Q 1% Q 5% Q N Q 50% Q 100% Q MAX Q 0.3% Q 1% Q 5% Q N Q 50% Q 100% Q MAX<br />

10 0,003 0,01 0,04 0,20 0,39 0,79 0,98 0,008 0,03 0,14 0,80 1,41 2,83 3,53<br />

15 0,005 0,02 0,09 0,50 0,88 1,77 2,21 0,019 0,06 0,32 2,00 3,18 6,36 7,95<br />

20 0,009 0,03 0,16 0,90 1,57 3,14 3,93 0,034 0,11 0,57 3,20 5,65 11,31 14,14<br />

25 0,015 0,05 0,25 1,40 2,45 4,91 6,14 0,053 0,18 0,88 5,00 8,84 17,67 22,09<br />

32 0,024 0,08 0,40 2,20 4,02 8,04 10,05 0,087 0,3 1,5 8,00 14,5 29,0 36,2<br />

40 0,04 0,1 0,6 4,0 6,3 12,6 15,7 0,14 0,5 2,3 13,0 22,6 45,2 56,6<br />

50 0,06 0,2 1,0 6,0 9,8 19,6 24,5 0,21 0,7 3,5 20,0 35,3 70,7 88,4<br />

65 0,10 0,3 1,7 9,0 16,6 33,2 41,5 0,36 1,2 6,0 35,0 59,7 119,5 149,3<br />

80 0,15 0,5 2,5 14,0 25,1 50,3 62,8 0,54 1,8 9,0 50,0 90,5 181,0 226,2<br />

100 0,24 0,8 3,9 20,0 39,3 78,5 98,2 0,85 3 14 80 141 283 353<br />

125 0,4 1 6 30,0 61 123 153 1,3 4 22 150 221 442 552<br />

150 0,5 2 9 50,0 88 177 221 1,9 6 32 200 318 636 795<br />

200 0,9 3 16 100 157 314 393 3,4 11 57 300 565 1131 1414<br />

250 1,5 5 25 150 245 491 614 5,3 18 88 500 884 1767 2209<br />

300 2,1 7 35 200 353 707 884 7,6 25 127 800 1272 2545 3181<br />

350 2,9 10 48 300 481 962 1203 10 35 173 1000 1732 3464 4330<br />

400 3,8 13 63 400 628 1257 1571 14 45 226 1300 2262 4524 5655<br />

500 5,9 20 98 600 982 1963 2454 21 71 353 2000 3534 7069 8836<br />

600 8,5 28 141 800 1414 2827 3534 31 102 509 3000 5089 1017 1272<br />

700 12 38 192 1000 1924 3848 4811 42 139 693 4000 6927 1385 1731<br />

800 15 50 251 1200 2513 5027 6283 54 181 905 5000 9048 1809<br />

Preferred range<br />

Preferred range 6<br />

2262<br />

0<br />

Q 0.3%<br />

Q 1%<br />

Q 5%<br />

Q N<br />

Q 50%<br />

Q 100%<br />

Q MAX<br />

- <strong>M920</strong> minimum applicable flow rate (minimum flow rate with guaranteed accuracy)<br />

- <strong>M910</strong>, M930 minimum applicable flow rate (minimum flow rate with guaranteed accuracy)<br />

- recommended minimum flow rate (minimum flow rate with best accuracy)<br />

- recommended nominal flow rate (expected working flow rate)<br />

- recommended maximum flow rate (maximum flow rate for industrial use)<br />

- maximum applicable flow rate (maximum flow rate with guaranteed accuracy)<br />

- maximum applicable overload (Q 125% ) (<strong>flowmeters</strong> is still measuring)<br />

A sensor diameter should be chosen to keep real flow rate between Q 5% and Q 50% , because in this<br />

range the <strong>flowmeters</strong> has the best accuracy.


Accessories & Options<br />

selection<br />

Grounding rings<br />

Principle of operation of electromagnetic<br />

flowmeter requires the working liquid to<br />

be conductive and grounded. To meet<br />

this condition in systems with plastic<br />

pipes grounding rings can be ordered.<br />

The rings are inserted between sensor<br />

flange and flange of the pipe and<br />

electrically connected to ground.<br />

Compact / Remote conversion set<br />

Remote set is for conversion M-<br />

910/910E/920 from compact to remote<br />

version. Compact set is for conversion<br />

M-910/910E/920 from remote to<br />

compact version. Sets contain all parts<br />

and description how to convert the<br />

flowmeter.<br />

Spare sealing compound<br />

Re-enterable insulating and sealing compound is used for<br />

remote version to reach the protection IP67 (IP68). One part is<br />

standard part of delivery (remote version M-910/910E/920).<br />

Terminal boxes (with connected wires) should be filled this<br />

sealing compound.


Software<br />

Flow920<br />

• Standard part of delivery<br />

• Save and recall instrument setting<br />

• Easy calibration<br />

• Service functions<br />

• Password protection<br />

• Connection via RS232 or RS485<br />

Windows 2000/XP/Vista/7<br />

Flow920 software is program for remote control of the flowmeter M-910/910E/920/930. With<br />

the program configuration and calibration of the transmitter can be performed easily.<br />

Flowmeter<br />

Meter's configuration<br />

- units<br />

- resolution<br />

- low flow cut-off<br />

- real time clock<br />

- temperature alarm<br />

General<br />

Information about<br />

meter<br />

- nominal diameter<br />

- nominal flowrate<br />

- serial number<br />

- power supply<br />

- save/restoresettings<br />

Calibration<br />

Meter's calibration<br />

- 2...4 calibration<br />

points<br />

- calibration curve<br />

- calibration constants<br />

calculation<br />

Input/Output<br />

I/O configuration<br />

- current loop 20mA<br />

- frequency output<br />

- pulse output<br />

- status output<br />

- digital input<br />

Service<br />

Service information<br />

- internal voltages<br />

- internal temperature<br />

- last errors<br />

Main<br />

Basic information<br />

- flow rate<br />

- volume<br />

- batch<br />

- min./max. values<br />

Data logger<br />

Charts printing


Ordering information<br />

Model Ordering code Description<br />

<strong>M910</strong> V 0 0 0 0 DN 50 PN16<br />

Model<br />

<strong>M910</strong>E<br />

Low cost version<br />

<strong>M910</strong><br />

Basic version<br />

<strong>M920</strong><br />

High accuracy version<br />

Liner<br />

0 Hard rubber<br />

1 Soft rubber<br />

2 PTFE<br />

Electrodes<br />

0 CrNi steel<br />

1 Hastelloy C276<br />

2 Tantalum<br />

Power supply<br />

0 115V/230V, 50/60 Hz<br />

1 12V DC<br />

2 24V DC/AC, 50/60 Hz<br />

3 48V DC/AC, 50/60 Hz<br />

Construction<br />

0 Compact version<br />

1 Remote version<br />

Flanges<br />

DN<br />

DIN<br />

ANSI<br />

ANSI<br />

Diameter<br />

50 10 ... 800mm (1/2 ... 32")<br />

Pressure<br />

PN16 10 ... 40bar (150 ... 300lb)<br />

Ordering example<br />

<strong>M910</strong>E-V2120 DN15 PN25<br />

Liner: PTFE Electrodes: hastelloy C276<br />

Power supply: 24 V DC/AC Construction: compact version<br />

Nominal diameter: 15 mm Nominal pressure: 25 bar

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!