Sink Type Logic<br />
MC<br />
ON<br />
OFF<br />
AX<br />
MC<br />
AX<br />
ELB<br />
Power source,<br />
3-phase or 1-phase,<br />
per inverter model<br />
Using source logic of external<br />
machine output and/or external<br />
power supply, please refer to P24.<br />
Thermistor<br />
MC<br />
Short bar<br />
R/L1<br />
S/L2<br />
T/L3<br />
P24<br />
PLC<br />
L<br />
24VDC<br />
L<br />
U/T1<br />
V/T2<br />
W/T3<br />
PD/+1<br />
P/+<br />
RB<br />
Short bar<br />
DCL<br />
AL1<br />
IM<br />
Motor<br />
Remove the jumper<br />
only when connecting<br />
the DCL.<br />
Breake resistor (option)<br />
7/EB<br />
4.7kΩ<br />
6<br />
N/-<br />
AL2<br />
Intelligent input<br />
terminals (7)<br />
5/PTC<br />
4/GS2<br />
3/GS1<br />
2<br />
AL0<br />
AL1<br />
AL2<br />
Relay contacts,<br />
type 1 Form C<br />
1<br />
4.7kΩ<br />
12<br />
1kΩ – 2kΩ<br />
10VDC<br />
(10mA max.)<br />
H<br />
10VDC<br />
11/EDM<br />
Intelligent output terminals (2)<br />
Analog refernce<br />
0–10VDC (10 bit)<br />
O<br />
Analog refernce<br />
4–20mA (10bit)<br />
Approx.10kΩ<br />
OI<br />
Approx.100Ω<br />
Terminal resistor 200Ω<br />
CM2<br />
SP<br />
Pluse train input<br />
5–24VDC<br />
(32kHz max.)<br />
EA<br />
L<br />
Serial communication port<br />
(RS485/Modbus-RTU)<br />
L<br />
SN<br />
Analog output<br />
0–10VDC (10 bit)<br />
AM<br />
L<br />
Termination resistor<br />
selection switch<br />
Using Dynamic breaking unit (BRD)<br />
Pluse output<br />
0–10V (32kHz max.)<br />
EO<br />
L<br />
P/+<br />
Braking unit<br />
Braking resistor<br />
L<br />
L<br />
RB<br />
P<br />
P<br />
L<br />
N/-<br />
N<br />
RB<br />
Type-D grounding (200 V class model)<br />
Type-C grounding (400 V class model)<br />
23