30.12.2014 Views

water heating - Advanced Water

water heating - Advanced Water

water heating - Advanced Water

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

technical specifications<br />

Cable size<br />

Cable size will depend on the length of the<br />

cable run. Showers up to 9.5kW require a<br />

minimum of 6mm 2 cable routed directly to the<br />

main fuse box and a 40A fuse.<br />

10.5kW showers require a minimum of 10mm 2<br />

cable and a 45A fuse.<br />

<strong>Water</strong><br />

Connects directly to the cold mains <strong>water</strong><br />

supply with minimum working pressure 15psi<br />

(1bar), at a flow rate of 8 litres per minute;<br />

maximum working pressure 150psi (10bar).<br />

All electrical installations must conform to the<br />

IEE regulations.<br />

Model Features aX 1 aX 2 aX 3 aX 4<br />

1.25m Flexible Hose • • • •<br />

Riser Rail with 530mm Height Adjustment • • • •<br />

High Temperature Safety Cut Out • • • •<br />

Flow Stabiliser Valve • • • •<br />

Power ‘On’ Indicator • • • •<br />

Rotary Power Selection • • • -<br />

Push Button Power Selection - - - •<br />

Cold, Medium and High Settings • • • •<br />

Detachable Soap Dish - • • •<br />

Numbered Temperature Dial - • • •<br />

6 Mode Rub Clean Handset - - • •<br />

Single Mode Handset • • - -<br />

Push Button Start/Stop - - • •<br />

Auto Reset Indicator - • • •<br />

Low Pressure Indicator - - - •<br />

Automatic Phased Shut Down - - - •<br />

Multipoint Pipe Entry 2 3 3 3<br />

Multipoint Cable Entry • • • •<br />

2 Year Manufacturers Guarantee • • • •<br />

Optional Extended Warranty • • • •<br />

Kilowatts Available (Rating at 240V)<br />

7.5kW • • - -<br />

8.5kW • • • •<br />

9.5kW - - • •<br />

10.5kW - - • •<br />

All Chrome<br />

Finish White/ White/ White/ White/<br />

Chrome Chrome Chrome Chrome<br />

Dimensions<br />

Height 335mm 339mm 339mm 339mm<br />

Length 190mm 218mm 218mm 218mm<br />

Depth 90mm 85mm 85mm 85mm<br />

Minimum running pressure must be obtained<br />

at 9 litres/minute for 9.5kW rated models and<br />

11 litres/minute for the 10.5kW rated models.<br />

aX range<br />

29