<strong>KRYOCLIM</strong> ® SYSTEM<br />
2000<br />
GENERAL CHARACTERISTICS<br />
OPERATIONS CONDITIONS<br />
Technical Sheet<br />
1.4<br />
WORKING PRESSURE AND TEMPERATURE<br />
10 bar from - 30°C to + 20°C<br />
(PMS)<br />
10 bars<br />
MAXIMUM WORKING<br />
PRESSURE<br />
The flow temperature of some networks (such as process or<br />
defreezing of convection fans) can reach more than 20°C.<br />
<strong>KRYOCLIM</strong> ® allows a maximum temperature of 40°C with a<br />
maximum pressure of 7 bar.<br />
7 bars<br />
Fluid Température<br />
temperature<br />
du fluide<br />
■ WORKING LIFETIME :<br />
-30 -20 -10 0 10 20 30 40 (°C)<br />
The working pressure and temperature indicated in the following tables are determined for a working life of 50<br />
years without interruption.<br />
Working pressures according to working temperatures are figured out by using regression curves as per standard<br />
NF T 54-091.<br />
■ TESTING PRESSURE<br />
PN<br />
Testing pressure<br />
1 hour (20°C)<br />
4,2 PN<br />
10 42 bars<br />
2,5 PN<br />
1 heure 100 h 1000 h 10 000 h 50 ans<br />
A pressure pipework can be classified as PN 10 (with a safety factor of 2.5 after 50 years) if it can tolerate, during<br />
one hour, a pressure equal to 4.2 times this PN. The characteristics of the system can only be guaranteed to 50<br />
years by combining these two parameters.<br />
The readings for the breaking pressures for <strong>KRYOCLIM</strong> ® change, as shown in a straight-line in logarithmic co-ordinates.<br />
Considering the safety cœfficients, the pressure ratio between 50 years and one hour ranges from 4.2 to 2.5. This<br />
straight line is drawn on the basis of the 1 hr, 100 hr, 1000 hr and 10,000 hr tests, and is then extrapolated to 50<br />
years.<br />
■ GARANTIES :<br />
• For all applications specified in the technical documentation, regardless of pipe diameter, GIRPI has an insurance<br />
to guarantee installations which are carried out in accordance with its own general recommendations, and which<br />
respect the temperature and pressure conditions and the nature of fluid specified above.