<strong>McGean</strong>-Rohco, Inc.<br />

2910 Harvard Avenue<br />

Cleveland, Ohio 44105-3010 <strong>USA</strong><br />

Phone: 216-441-4900 Fax: 216-441-1377<br />

www.mcgean.com<br />

MATERIAL SAFETY DATA SHEET<br />

23031<br />

© 2014 <strong>McGean</strong>-Rohco, Inc. PAGE 1 OF 4<br />

PRODUCT NAME: CEE-BEE A-292NC <strong>MSDS</strong> No.: 23031<br />

REVISION: 6<br />

PREPARED BY: DIR ENV AFFAIRS ISSUE DATE:03/01/83 EFFECTIVE DATE: 06/20/13<br />

--------------------------------------------------------------------------------<br />

SECTION A. MATERIAL IDENTIFICATION.<br />

MANUFACTURER: McGEAN-ROHCO, INC.<br />

CHEMTREC:<br />

TELEPHONE #: 800-424-9300<br />

38521 SCHOOLCRAFT AVE. OR 703-527-3887<br />

LIVONIA MI 48150<br />

TELEPHONE: 216-441-4900<br />

--------------------------------------------------------------------------------<br />

SECTION B. INGREDIENTS AND HAZARDS.<br />

INGREDIENT: METHYLENE CHLORIDE<br />

SARA 313 CHEMICAL<br />

70.0 - 80.0%<br />

CAS NUMBER: 75-09-2<br />

EXPOSURE LIMIT: TWA: OSHA - 25 PPM, ACGIH - 50 PPM<br />

SUSPECT CARCINOGEN: YES<br />

INGREDIENT: TOLUENE SARA 313 CHEMICAL<br />

1.0 - 5.0%<br />

CAS NUMBER: 108-88-3<br />

EXPOSURE LIMIT: TWA: OSHA & ACGIH, 375mg/CUBIC METER<br />

SUSPECT CARCINOGEN: NO<br />

INGREDIENT: ETHANOL<br />

5.0 - 10.0%<br />

CAS NUMBER: 64-17-5<br />

EXPOSURE LIMIT: TWA: OSHA-1900: ACGIH-1880mg/CU METER<br />

SUSPECT CARCINOGEN: NO<br />

INGREDIENT: METHANOL--SARA 313 CHEMICAL<br />

1.0 - 5.0%<br />

CAS NUMBER: 67-56-1<br />

EXPOSURE LIMIT: TWA: OSHA & ACGIH-260mg/CUBIC METER<br />

SUSPECT CARCINOGEN: NO<br />

INGREDIENT: AQUA AMMONIA<br />

1.0 - 5.0%<br />

CAS NUMBER: 1336-21-6<br />

EXPOSURE LIMIT: TWA: OSHA-35ppm: ACGIH-25ppm<br />

SUSPECT CARCINOGEN: NO<br />

--------------------------------------------------------------------------------


<strong>McGean</strong>-Rohco, Inc.<br />

2910 Harvard Avenue<br />

Cleveland, Ohio 44105-3010 <strong>USA</strong><br />

Phone: 216-441-4900 Fax: 216-441-1377<br />

www.mcgean.com<br />

MATERIAL SAFETY DATA SHEET<br />

23031<br />

© 2014 <strong>McGean</strong>-Rohco, Inc. PAGE 2 OF 4<br />

SECTION C. PHYSICAL DATA.<br />

APPEARANCE: THICK,YELLOW-BROWN LIQUID. BOILING POINT: 104F<br />

ODOR: AMMONIA FREEZING POINT:


<strong>McGean</strong>-Rohco, Inc.<br />

2910 Harvard Avenue<br />

Cleveland, Ohio 44105-3010 <strong>USA</strong><br />

Phone: 216-441-4900 Fax: 216-441-1377<br />

www.mcgean.com<br />

MATERIAL SAFETY DATA SHEET<br />

23031<br />

© 2014 <strong>McGean</strong>-Rohco, Inc. PAGE 3 OF 4<br />

MEDICAL CONDITIONS<br />

WHICH MAY BE<br />

AGGRAVATED BY CONTACT:<br />

TARGET ORGANS:<br />

DERMATITIS,LIVER AND KIDNEY DISEASES.<br />

PANCREAS,SPLEEN,LUNGS,LIVER,EYES,SKIN,CVS,CNS.<br />

PRIMARY ENTRY ROUTES: CONTACT AND INHALATION.<br />

ACUTE EFFECTS:<br />

IRRITATION<br />

CHRONIC EFFECTS:<br />

AFFECT ALL TARGET ORGANS.<br />

SIGNS & SYMPTOMS OF OVEREXPOSURE:<br />

EYE CONTACT: IRRITATION OR BURNING SENSATION<br />

SKIN CONTACT: IRRITATION, DRYING OR FLAKING OF SKIN.<br />

INGESTION:<br />

UNCONSCIOUSNESS AND DEATH. DARK URINE, HEADACHE, DIZZINESS.<br />

NAUSEA.SEVERE ABDOMINAL PAIN.<br />

EMERGENCY & FIRST AID PROCEDURES:<br />

EYE CONTACT: FLUSH WITH WATER FOR AT LEAST 15 MINUTES.GET MEDICAL<br />

ATTENTION.<br />

SKIN CONTACT: WASH OFF IN FLOWING WATER. WASH WITH SOAP AND WATER.<br />

INHALATION: REMOVE TO FRESH AIR. CALL A PHYSICIAN.<br />

INGESTION: GIVE A LARGE QUANTITY OF WATER.DO NOT INDUCE VOMITING.<br />

CALL A PHYSICIAN AND/OR TAKE TO EMERGENCY MEDICAL FACILITY.<br />

--------------------------------------------------------------------------------<br />

SECTION G. SPILL, LEAK AND DISPOSAL PROCEDURES.<br />

SPILL/LEAK MOP,WIPE UP OR SOAK UP IMMEDIATELY WITH ABSORBANT.WEAR<br />

PROCEDURES: PROPER PROTECTIVE EQUIPMENT.


<strong>McGean</strong>-Rohco, Inc.<br />

2910 Harvard Avenue<br />

Cleveland, Ohio 44105-3010 <strong>USA</strong><br />

Phone: 216-441-4900 Fax: 216-441-1377<br />

www.mcgean.com<br />

MATERIAL SAFETY DATA SHEET<br />

23031<br />

© 2014 <strong>McGean</strong>-Rohco, Inc. PAGE 4 OF 4<br />

WASTE<br />

MANAGEMENT<br />

& DISPOSAL<br />

PROCEDURES:<br />

SEND TO AN APPROVED WASTE DISPOSAL FACILITY.<br />

FOLLOW ALL LOCAL,STATE AND FEDERAL REGULATIONS.<br />

RCRA # (IF DISPOSED AS RECEIVED): F-002<br />

--------------------------------------------------------------------------------<br />

SECTION H. SPECIAL PROTECTION INFORMATION<br />

PERSONAL PROTECTIVE EQUIPMENT:<br />

GOGGLES: CHEMICAL GOGGLES AND FACE SHIELD.<br />

GLOVES: CHEMICALLY RESISTANT APRON, BOOTS AND GLOVES RECOMMENDED.<br />

RESPIRATOR: IF TWA'S ARE EXCEEDED,MUST BE NIOSH OR MSHA APPROVED.<br />

OTHER:<br />

SUFFICIENT TO PREVENT SKIN CONTACT.<br />

WORKPLACE CONSIDERATIONS:<br />

VENTILATION: SUFFICIENT TO KEEP BELOW TWA LIMITS.<br />

SAFETY STATIONS: EYE WASH<br />

OTHER:<br />

SAFETY SHOWER<br />

--------------------------------------------------------------------------------<br />

SECTION I. SPECIAL PRECAUTIONS<br />

SPECIAL HANDLING STORE IN A COOL,DRY,WELL VENTILATED AREA AT 32-<br />

& STORAGE PROCEDURES: 90 F.OPEN CONTAINERS SLOWLY AND WITH CAUTION IN<br />

ORDER TO VENT IN CASE THERE IS PRESSURE BUILD UP.<br />

D.O.T. CLASS 6.1 UN REGISTER: UN-2810<br />

IMDG CLASS: 6.1 UN REGISTER: UN-2810<br />

IATA CLASS: 6.1 UN REGISTER: UN-2810<br />

--------------------------------------------------------------------------------<br />

EXPLANATION OF SYMBOLS<br />

NA = NOT APPLICABLE<br />

UK = UNKNOWN<br />

--------------------------------------------------------------------------------<br />

THIS MATERIAL SAFETY DATA SHEET IS OFFERED SOLELY FOR YOUR INFORMATION,<br />

CONSIDERATION, AND INVESTIGATION. WHILE THE INFORMATION AND RECOMMENDATIONS<br />

SET FORTH HEREIN ARE BELIEVED TO BE ACCURATE AS OF THE DATE HEREOF,<br />

McGEAN-ROHCO, INC. MAKES NO WARRANTY WITH RESPECT THERETO AND DISCLAIMS ALL<br />

LIABILITY FROM RELIANCE THEREON.<br />

THIS MATERIAL SAFETY DATA SHEET HAS BEEN PREPARED TO COMPLY WITH<br />

TITLE 29 CODE OF FEDERAL REGULATIONS, PART 1910.1200, OSHA HAZARD<br />

COMMUNICATION STANDARD, AND TO FULFILL THE ANNUAL CHEMICAL NOTIFICATION<br />

REQUIREMENTS OF SARA TITLE III, SECTION 313.