5.4 Start/stop/emergency stop<br />

■ The main swith on the machine (7) must be switched to position 1 (ON).<br />

■ Compressed air must be connected and the compressed air cock must be open (9 and 10).<br />

■ The main switch on the glue tank must be switched to ON position. Check that there is glue in the<br />

tank.<br />

■ Check that all necessary carton size settings have been made (see the section “Setting of<br />

formats”).<br />

■ Close the doors in the guarding and check that the emergency stop switch (5) is pulled out.<br />

■ Push the AIR ON button (3). Air is connected to the machine and the white pushbutton with light<br />

(3) lights constantly. If this is not the case see the chapter regarding alarms.<br />

■ Push start (1). The machine now automatically starts a top sealing sequence. The green<br />

pushbutton with light lights constantly. If this is not the case see the chapter on handling of<br />

alarms.<br />

IMPORTANT: The glue tank indicator lamp must light green otherwise it is not possible to start the carton<br />

sealer. If the indicator lamp switches off when the machine is in operation the machine stops and it<br />

cannot be restarted until the indicator lamp lights.<br />

Stop<br />

Push the black button stop/reset (2) briefly to stop the machine when the top sealing sequence has<br />

ended.<br />

Reset<br />

Push the black stop/reset button (2) for 5 seconds to reset the machine until the green start button (1)<br />

flashes 3 times. This function is used when an alarm has occurred (see alarm instructions). All functions<br />

are reset which means that the machine returns to its initial position when air has been supplied to the<br />

machine or when air is supplied to the machine again.<br />

Emergency stop switch<br />

If the emergency stop switch (5) is activated the machine stops and is vented immediately. This also<br />

takes place if a door is opened.<br />

Queue control photocell S10<br />

When the photocell for queue control S10 (see wire diagrams) is activated the top sealing sequence is<br />

completed and the machine waits with the carton in the compression arrangement. When the photocell<br />

is free the carton is led out of compression arrangement and a new carton is led into the compression<br />

arrangement for sealing.<br />

9732850011_<strong>HM</strong>-<strong>4200</strong> <strong>GB</strong>_Version 3_2011.11.17<br />

Programme operation without cartons<br />

The machine is preprogrammed to operate without glueing for demonstration purposes. It is not required<br />

that the glue tank is connected and it is also not required that the movement speeds are adjusted. The<br />

machine must be stopped.<br />

■ Push the start button (1) and the stop button (2) for 3 seconds until the white AIR ON button (3)<br />

flashes 3 times.<br />

■ Now release the start button (1) and then push start again and the machine carries out the entire<br />

sequence over and over again until the stop button is activated.<br />