08.01.2015 Views

Catalogue - EVAPCO Europe NV

Catalogue - EVAPCO Europe NV

Catalogue - EVAPCO Europe NV

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

P R O V I D I N G E A S I E R S O L U T I O N S A N D B E T T E R C H O I C E S<br />

<br />

WST Air Inlet Louvers<br />

(Water and Sight Tight)<br />

• Easily removable for access.<br />

• Designed to keep sunlight outpreventing<br />

biological growth.<br />

• Keeps water in while keeping dirt<br />

and debris out.<br />

DESIGN AND CONSTRUCTION FEATURES<br />

The new ESWA closed circuit cooler is another exciting product from <strong>EVAPCO</strong>. The ESWA is a new high performance<br />

version of the original ESW with greater capacity, more models and increased energy savings! The new ESWA is able to<br />

provide higher performance as a result of our new Sensi-Coil Technology, a new coil design that provides significant<br />

performance improvements on every ESWA model.<br />

Sensi-Coil Technology features over 20% more Thermal-Pak ® elliptical tubes packed densely together into the same coil<br />

plan area as the original ESW. This design also has 50% more water loading than the previous ESW line. More surface<br />

area plus more water equals higher capacity resulting in more performance with the ESWA in a smaller footprint with<br />

less energy.<br />

TM<br />

New<br />

Technology<br />

The NEW Sensi-Coil , exclusive on the new ESWA closed circuit cooler, features the<br />

maximum amount of Thermal-Pak elliptical tubes packed densely together in a new<br />

coil arrangement.<br />

The new Sensi-Coil transfers heat through its tube walls<br />

in a sensible exchange - No air travels through the tube<br />

bundle, therefore tighter tube spacing is possible. Look at<br />

the side by side tube spacing comparison below.<br />

Sensi-Coil <br />

Sensi-Coil <br />

Original Thermal-Pak Coil<br />

used in the ESW<br />

The Sensi-Coil Features:<br />

• More Thermal-Pak ® elliptical tubes densely packed together<br />

into the same plan area used on the original ESW.<br />

• Over 20% more coil surface area than the original ESW coil.<br />

• Higher water loading capability for more heat rejection,<br />

increasing from 8 l/s per m 2 to 12 l/s per m 2 , a 50% increase!<br />

• More surface area and more water equals higher capacity<br />

and increased energy efficiency.<br />

This innovative tight tube spacing is designed specifically to<br />

maximize sensible heat transfer, and is exclusive on the<br />

ESWA product line.<br />

Most Accessible<br />

Basin and Coil<br />

• Side access.<br />

• Large open area simplifies<br />

maintenance.<br />

• Basin may be inspected with<br />

pumps running.<br />

3<br />

DESIGN MAINTENANCE OPTIONS SOUND I B C C T I ENGINEERING SPECIFICATIONS