| HomeWorks® system maximums<br />
System Maximums<br />
Zones per HomeWorks Processor<br />
Processors per system<br />
Zones per system<br />
EDUs per HWI-Q96 interface<br />
HWI-Q96 interfaces per H48/Q96 Link<br />
Link 4, 5, 6 (or 8 in 8 series only) can be configured as<br />
a H48/Q96 Link<br />
256<br />
Each EDU uses one zone of the HomeWorks system<br />
16<br />
4096<br />
96<br />
4 total interfaces (H48 and/or HWI-Q96)<br />
Maximum 1 H48/Q96 link per HomeWorks processor<br />
Sivoia QED interface for HomeWorks<br />
Interface for Sivoia QED<br />
Addressing<br />
Low Voltage Wiring<br />
Wiring configurations – HomeWorks Link<br />
Wiring Configurations – Sivoia QED Link<br />
Setting Limits<br />
Power<br />
Sivoia QED Controllability for HomeWorks<br />
HWI-Q96<br />
Connects to configurable link configured as an H48/Q96<br />
Link<br />
• Installs in any low voltage enclosure<br />
• A second HWI-Q96 is only required when the total<br />
number of EDUs per system exceeds 96<br />
HWI-Q96 interface addresses with dip switches<br />
EDUs are addressed via serial addressing in the Home-<br />
Works software<br />
See page 3.8<br />
Daisy chain ONLY between processor and interface –<br />
max 305m cable<br />
Refer to HomeWorks <strong>Technical</strong> <strong>Reference</strong> <strong>Guide</strong><br />
Daisy chain or home-run EDUs to power panel<br />
(maximum 305m per single run<br />
Maximum 1220m total wire distance for Sivoia QED link<br />
Refer to Sivoia QED Wiring and Programming <strong>Guide</strong> (p/n<br />
045-101-12 rev A)<br />
Limits can be set from the EDU or from the HomeWorks<br />
Software<br />
The HWI-Q96 is powered by the Sivoia QED link<br />
• Lighting and Sivoia QED zones can be programmed<br />
at any level between 0% - 100%.<br />
• For Sivoia QED, 0% equals fully closed and 100%<br />
equals fully open<br />
• Any EDU in the system can be programmed to any<br />
HomeWorks keypad in the system at any level<br />
• Sivoia QED zones can be included in security mode,<br />
vacation mode and scene save programming<br />
• Sivoia QED zones can also be controlled via RS232<br />
and will provide system feedback to the processor<br />
• Sivoia QED keypads may be used but count against<br />
the 96 device limit<br />
• Sivoia QED keypads cannot be programmed using the<br />
HomeWorks software<br />