HARVEL CPVC PIPE<br />

IRRIGATION<br />

Schedule 40 NSF**<br />

Nominal<br />

Pipe Size Average Nominal Max. W.P.<br />

(In.) O.D. I.D. Min.Wall Wt./Ft PSI*<br />

1/4 0.540 0.354 0.088 0.091 780<br />

3/8 0.540 0.483 0.091 0.122 620<br />

1/2 0.840 0.608 0.109 0.180 590<br />

3/4 1.050 0.810 0.133 0.239 480<br />

1 1.315 1.033 0.133 0.352 450<br />

1 1/4 1.660 1.364 0.140 0.475 365<br />

1 1/2 1.900 1.592 0.145 0.568 330<br />

2 2.375 2.049 0.154 0.761 275<br />

2 1/2 2.875 2.445 .203 1.201 300<br />

3 3.500 3.042 0.216 1.572 260<br />

3 1/2 4.000 3.520 0.226 1.905 240<br />

4 4.500 3.998 0.237 2.239 220<br />

6 6.625 6.031 0.280 3.945 180<br />

8 8.625 7.943 0.322 5.958 160<br />

10 10.750 9.976 0.365 8.458 140<br />

12 12.750 11.890 0.406 11.172 130<br />

Schedule 80 NSF**<br />

Nominal Max. W.P. Max. W.P.<br />

Pipe Size Average Nominal PSI* PSI*<br />

(In.) O.D. I.D. Min.Wall Wt./Ft Plain End Threaded<br />

1/4 0.540 0.288 0.119 0.112 1130 565<br />

3/8 0.540 0.407 0.126 0.154 920 460<br />

1/2 0.840 0.528 0.147 0.225 850 425<br />

3/4 1.050 0.724 0.154 0.305 690 345<br />

1 1.315 0.935 0.179 0.449 630 315<br />

1 1/4 1.660 1.364 0.140 0.475 365 260<br />

1 1/2 1.900 1.592 0.145 0.568 330 235<br />

2 2.375 2.049 0.154 0.761 275 200<br />

2 1/2 2.875 2.445 .203 1.201 300 210<br />

3 3.500 3.042 0.216 1.572 260 185<br />

3 1/2 4.000 3.520 0.226 1.905 240 175<br />

4 4.500 3.998 0.237 2.239 220 160<br />

6 6.625 6.031 0.280 3.945 180 140<br />

8 8.625 7.943 0.322 5.958 160 125<br />

10 10.750 9.976 0.365 8.458 140 115<br />

12 12.750 11.890 0.406 11.172 130 115<br />

PVC PIPE<br />

To be applied to 73.4 F<br />

working pressures with<br />

water for SDR, Schedules<br />

40, 80, and 120<br />

PVC pipe, either Type<br />

1120 2110.<br />

Working<br />

Temp. (F)<br />

De-Rating<br />

Factor<br />

73 1.00<br />

80 0.88<br />

90 0.75<br />

100 0.62<br />

110 0.51<br />

120 0.40<br />

130** 0.31<br />

140** 0.22<br />

Temperature De-Rating Factors<br />

CPVC PIPE<br />

To be applied to 73.4 F<br />

Working De-Rating<br />

working pressures with<br />

Temp. (F) Factor<br />

water for Schedules 40, 73 1.00<br />

80 CPVC pipe.<br />

110 0.72<br />

120 0.65<br />

130 0.57<br />

140** 0.50<br />

150** 0.42<br />

160** 0.40<br />

170** 0.29<br />

180** 0.25<br />

200** 0.20<br />

*Water at 73.4 F. Standard length 20 feet,<br />

plain end.<br />

Schedules 40 and 80 CPVC pipe meet ASTM<br />

Standard 1784 for materials and F-441 (formerly<br />

1785) for pipe. Sizes preceded by are not normally<br />

carried in stock.<br />

**Pipe should not be threaded. Use flanged<br />

joints, unions, or victaulic rolled groove couplings<br />

where disassembly is necessary. Operating<br />

temperatures above 140F for PVC and<br />

200 F are not recommended.<br />

For Chemical Resistance Charts, log onto our website at www.ewing1.com and navigate to<br />

resources / technical references / chemical resistance guide.<br />

292<br />

<strong>Irrigation</strong> Golf Industrial 3441 E. HARBOUR DRIVE • PHOENIX, AZ 85034