You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
\<br />
Primo Personal / Aluminium circuit breakers / With protective conductor monitoring<br />
Extension cable with mobile PRCD-S circuit breaker, 230 V~, 16 A, 30 m A, IP44<br />
∙ Cable lengths: plug – PRCD-S: 0.15 m<br />
PRCD-S – coupling: 3.0 m<br />
∙ Portable PRCD-S circuit breaker fitted with H07RN-F 3G 1.5 mm² cable<br />
∙ Supplied in a robust case<br />
Art. no. Version Unit<br />
Mobile PRCD-S personal circuit breaker<br />
1x protective conductor monitoring<br />
∙ End 1: solid rubber right angle plug with 2 earthing contact systems<br />
∙ End 2: solid rubber coupling with cover, protection type IP44<br />
919.014 ∙ Black 1 item<br />
1x protective conductor monitoring<br />
∙ End 1: solid rubber right angle plug with 2 earthing contact systems<br />
∙ End 2: solid rubber coupling, 3-way with cover, protection type IP44<br />
919.015 ∙ Black 1 item<br />
PRCD-S 230 V~, 16 A, 30 m A, IP55<br />
∙ For cable cross section 1 mm² – 2.5 mm²<br />
∙ Test marks by BG (German employers' liability association), Cologne SEV, VDE, GS<br />
Art. no. Version Unit<br />
PRCD-S<br />
1x protective conductor monitoring<br />
∙ PRCD-S<br />
∙ Rated residual current 30 m A<br />
919.016 ∙ Black 1 item<br />
PRCD-K 230 V~, 16 A, 30 m A, IP55<br />
∙ For cable cross section 1 mm² – 2.5 mm²<br />
∙ Test marks VDE, TÜV, GS<br />
Art. no. Version Unit<br />
PRCD-K<br />
1x differential current protection device 1x undervoltage tripping device<br />
919.018 ∙ Black 1 item<br />
Adaptors<br />
The advantages<br />
at a<br />
glance<br />
Scope of protection<br />
• Specially designed as a protective distributor for small construction sites as<br />
recommended by the BGFE employers' liability association, Cologne (ZH1 / 271),<br />
and for all portable <strong>electric</strong>al equipment.<br />
• Can be used irrespective of connector system<br />
• Undervoltage tripping<br />
• Offers protection as specified by DIN VDE 0661 in the event of a fault in the<br />
connected equipment. Fault currents arising from faulty consumers will cause<br />
the PRCD-S to interrupt all poles.<br />
• For system faults in the fixed installation, The PRCD-S detects all faults in the<br />
fixed installation and cannot then be switched on.<br />
bachmann.com<br />
255