Step 11 >>> Develop Load Test Program<br />
• Scope of Program<br />
‣ Include or not include<br />
‣ Consistent with selected FS or φ for grout/ground bond strength in<br />
geotechnical capacity evaluations;<br />
‣ FS min for verification and proof testing is 2.0<br />
‣ φ = Table 10.5.5.2.3-1 (For Driven Piles) but no greater than 0.70<br />
‣ Max test load should not exceed 80% of ultimate structural capacity