14.01.2015 Views

H-4191 Brochure - WaterLOG

H-4191 Brochure - WaterLOG

H-4191 Brochure - WaterLOG

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Model H-<strong>4191</strong><br />

RS-232 to SDI-12 Interface<br />

The <strong>WaterLOG</strong> ® Model H-<strong>4191</strong><br />

allows the user to interface to<br />

a laptop computer in order<br />

to configure and test SDI-12<br />

sensors as well as monitor the<br />

communication between a data<br />

logger and its sensors.<br />

The H-<strong>4191</strong> allows a PLC, RTU<br />

or other host device with a RS-<br />

232 port to access SDI-12<br />

sensors.<br />

KEY FEATURES<br />

• Provides both the electrical and protocol functions for interfacing a RS-232 host<br />

device to one or more SDI-12 sensors<br />

• Works with any sensor command & response message including vendor specific<br />

extended commands<br />

• Buffers the command so no special timing is required, even hand-typed<br />

commands will work<br />

• Generates proper parity for the SDI-12 bus<br />

• Automatically sends SDI-12 breaks & retries<br />

• Passes the sensor service request to the host<br />

• Supports optional CTS/RTS hardware flow control for a slow host device<br />

• Low power mode facilitates use with a RS-232 data radio<br />

• LED shows when the H-<strong>4191</strong> is awake<br />

• Built in “sensor” can measure the SDI-12 bus battery voltage<br />

Design Analysis Associates Inc. • 75 West 100 South Logan, Utah 84321 USA • Tel: (435) 753-2212 • Fax: (435) 753-7669 • sales@waterlog.com • www.waterlog.com


Specifications<br />

data input<br />

Internal<br />

Voltage<br />

Monitor<br />

(Address “Z”)<br />

Data Output<br />

Range 6-18V<br />

Resolution<br />

Accuracy ±1%<br />

8-bit (.08V)<br />

RS-232 Port Type Asynchronous, 9600 baud<br />

(fixed), 8-bit, no parity<br />

Flow Control<br />

Command Buffer<br />

SDI-12 Port Baud Rate 1200<br />

Protocol<br />

Output Voltage Levels<br />

RTS/CTS (optional)<br />

60 characters<br />

SDI-12, 7-bit even parity,<br />

1 stop bit<br />

Minimum<br />

high level:<br />

Maximum<br />

low level:<br />

3.5 volts<br />

0.8 volts<br />

Mechanical Data<br />

Physical Material ABS plastic<br />

Size<br />

3.75" Long x 2.65" Wide x 1.25" Deep<br />

Connectors RS-232 9-Pin, female,<br />

D-sub, DCE<br />

(modem)<br />

connections<br />

SDI-12<br />

Power Input Voltage 9 to 16.0 Volts DC<br />

Environment<br />

4-position terminal<br />

strip, pluggable,<br />

Phoenix<br />

Combicon<br />

Supply Current Sleep Mode 100 μ A typ<br />

Surge<br />

Protection<br />

Active<br />

Built in, 1.5 KVA<br />

Temperature Operating -40° C to +50° C<br />

Miscellaneous<br />

Warranty<br />

Note<br />

Storage<br />

-50° C to +70° C<br />

20mA typ<br />

The <strong>WaterLOG</strong>® H-<strong>4191</strong> is warranted against defects in<br />

materials and workmanship for one year from date of<br />

shipment.<br />

Specifications subject to change without prior notice<br />

due to ongoing commitment to product testing and<br />

improvement. LR February 15, 2011. D37 0211.<br />

Design Analysis Associates Inc. • 75 West 100 South Logan, Utah 84321 USA • Tel: (435) 753-2212 • Fax: (435) 753-7669 • sales@waterlog.com • www.waterlog.com