Measure Information Template Page 20<br />

5. Recommended Language for the Standards Document,<br />

ACM Manuals, and the Reference Appendices<br />

Part 6<br />

RESIDENTIAL STANDARDS:<br />

Subchapter 8<br />

● Section 151<br />

● Revise & Add: language to read as follows:<br />

● “Domestic <strong>Water</strong>-heating systems. <strong>Water</strong> heating systems shall meet the<br />

requirements of either A, B, C or D and meet the requirements of E and F or<br />

shall meet the requirements of Section 151(b)1.<br />

● D. For systems serving individual dwelling units using Package C, an electricresistance<br />

water heater may be installed as the main water heating source, only<br />

if the water heater is located within the building envelope and the minimum<br />

percent of the energy for water heating is provided by a passive or active solar<br />

system as specified in Table 151-B COMPONENT Package C<br />

● Table 151-B COMPONENT Package C<br />

● Remove: Footnote 7 from table and below text: “Electric-resistance water heating may<br />

be installed as the main water heating source in Package C only if the water heater is<br />

located within the building envelope and a minimum of 25 percent of the energy for<br />

water heating is provided by a passive or active solar system.<br />

● Adjust Climate Zones (see below)<br />

● Add to “<strong>Water</strong> <strong>Heating</strong>” section, an additional sub-row and include “If electricresistance,<br />

<strong>Solar</strong> Fraction = (See below),” and remove “or section 151 (b)1”<br />

Climate<br />

Zone<br />

<strong>Water</strong><br />

<strong>Heating</strong><br />

1 2 3 4 5 6 7 8 & 9 10 11 12 13 14 15 16<br />

System shall meet Section 151(f)8 or Section 151(b)1 7<br />

If electricresistance,<br />

<strong>Solar</strong><br />

Fraction = .65 .77 .77 .79 .84 .84 .86 .84 .85 .77 .75 .76 .81 .89 .75<br />

RESIDENTIAL MANUAL:<br />

● 5.1.3 <strong>Water</strong> Heater Types:<br />

o Add: <strong>Solar</strong> <strong>Water</strong> Heater w/ electric backup<br />

<strong>Solar</strong> <strong>Water</strong> Heater w/ natural gas backup<br />

2013 California Building Energy Efficiency Standards March 2011