Measure Information Template Page 20<br />
5. Recommended Language for the Standards Document,<br />
ACM Manuals, and the Reference Appendices<br />
Part 6<br />
RESIDENTIAL STANDARDS:<br />
Subchapter 8<br />
● Section 151<br />
● Revise & Add: language to read as follows:<br />
● “Domestic <strong>Water</strong>-heating systems. <strong>Water</strong> heating systems shall meet the<br />
requirements of either A, B, C or D and meet the requirements of E and F or<br />
shall meet the requirements of Section 151(b)1.<br />
● D. For systems serving individual dwelling units using Package C, an electricresistance<br />
water heater may be installed as the main water heating source, only<br />
if the water heater is located within the building envelope and the minimum<br />
percent of the energy for water heating is provided by a passive or active solar<br />
system as specified in Table 151-B COMPONENT Package C<br />
● Table 151-B COMPONENT Package C<br />
● Remove: Footnote 7 from table and below text: “Electric-resistance water heating may<br />
be installed as the main water heating source in Package C only if the water heater is<br />
located within the building envelope and a minimum of 25 percent of the energy for<br />
water heating is provided by a passive or active solar system.<br />
● Adjust Climate Zones (see below)<br />
● Add to “<strong>Water</strong> <strong>Heating</strong>” section, an additional sub-row and include “If electricresistance,<br />
<strong>Solar</strong> Fraction = (See below),” and remove “or section 151 (b)1”<br />
Climate<br />
Zone<br />
<strong>Water</strong><br />
<strong>Heating</strong><br />
1 2 3 4 5 6 7 8 & 9 10 11 12 13 14 15 16<br />
System shall meet Section 151(f)8 or Section 151(b)1 7<br />
If electricresistance,<br />
<strong>Solar</strong><br />
Fraction = .65 .77 .77 .79 .84 .84 .86 .84 .85 .77 .75 .76 .81 .89 .75<br />
RESIDENTIAL MANUAL:<br />
● 5.1.3 <strong>Water</strong> Heater Types:<br />
o Add: <strong>Solar</strong> <strong>Water</strong> Heater w/ electric backup<br />
<strong>Solar</strong> <strong>Water</strong> Heater w/ natural gas backup<br />
2013 California Building Energy Efficiency Standards March 2011