University of California at Riverside<br />

Site Evaluation Survey<br />

Report: UCR P5281 College Building South in Riverside, CA<br />

900 University Avenue<br />

61. Clear Space at Doors - Between Room #112 and Hall Entrance at<br />

Ground Level.<br />

Memo:<br />

Areas noted in compliance:<br />

Floor or landing is level and clear (2% max. slope).<br />

60” min. clear space in direction of door swing.<br />

44” min. clear space opposite direction of door swing (48” with latch and closer).<br />

Minimum strike side clearance on PULL side of door: 18” interior doors, front approach.<br />

Minimum strike side clearance on PUSH side of door: 0”.<br />

Areas not meeting new construction standards:<br />

None observed.<br />

Recommendation:<br />

None.<br />

Photo #UCR P5281 College Building South-61-1 (originally 0330-400)<br />