Report #UCR P5281 College Building South<br />

Report<br />

Name<br />

Item/Location<br />

Barrier<br />

(noted feature, item or area does not meet the<br />

new construction criteria detailed below)<br />

Action Priority Target<br />

Date<br />

Estimated<br />

Cost<br />

Interim Solution<br />

Action<br />

Completion<br />

Date<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

UCR<br />

P5281<br />

College<br />

Building<br />

South<br />

36-Aisles: Room #105 at<br />

Ground Level. [Relocate<br />

the table to provide clear<br />

width.]<br />

37-Electrical Controls &<br />

Receptacles/Fire Alarm<br />

Boxes: Room #105 at<br />

Ground Level.<br />

38-Doors: Door to the<br />

South Stairwell at<br />

Ground Level.<br />

39-Clear Space at<br />

Doors: Door to the<br />

South Stairwell at<br />

Ground Level.<br />

40-Stairways: South<br />

Stairwell at Ground<br />

Level.<br />

41-Stairway Handrails:<br />

South Stairwell at<br />

Ground Level.<br />

36" minimum width of aisles. Relocate furniture to provide<br />

clear space. University staff shall<br />

be instructed to place and<br />

maintain the placement of<br />

furniture to provide a clear path<br />

of travel and avoid the<br />

obstruction of accessible<br />

required clear spaces.<br />

The center of electrical receptacles or controls,<br />

and switches to control lighting, heating, cooling<br />

& appliances are 48" max. above the floor or<br />

working platform.<br />

Lower electrical control or<br />

other switch.<br />

32" minimum clear width of doorway. Replace door(s) and frame<br />

(stud wall).<br />

Floor or landing is level and clear (2% max.<br />

slope). 60" min. clear space in direction of door<br />

swing. 44" min. clear space opposite direction of<br />

door swing (48" with latch and closer).<br />

All risers are closed. 11" min. tread width. Int. -<br />

Top landing and lower tread have color striping<br />

minimum 2" wide and a maximum 4" wide<br />

parallel to, and not more than 1" maximum from<br />

tread nose or landing.<br />

Handrails are provided on both sides and are<br />

continuous for the full length of the stairway. 1-<br />

1/4" to 1-1/2" handgrip portion or cross section<br />

equivalent or the shape provides an equivalent<br />

gripping surface. 1-1/2" clearance provided<br />

between rail and wall. 12" minimum level<br />

extension beyond top nosing (parallel with the<br />

ground or floor surface) before being returned.<br />

12" plus one tread width level extension beyond<br />

bottom nosing (parallel with the ground or floor<br />

surface) before being returned.<br />

Requires<br />

engineering/architectural<br />

evaluation.<br />

Replace existing steps. Install<br />

slip-resistant color contrast<br />

striping to steps.<br />

Install new wall-mounted<br />

handrails.<br />

1M $61.25<br />

3 $7,240.86<br />

2 $3,136.07<br />

2 $7,115.62<br />

1 $10,104.07<br />

3 $4,904.66<br />

5/31/2012 Page 6 of 22