<strong>Task</strong> 3. <strong>Data</strong> <strong>Logger</strong> Based <strong>Telemetry</strong> Monitoring <strong>System</strong><br />
Power Supply Scheduled Maintenance Form<br />
Maintenance Performed by:<br />
Date: / / Time:<br />
Is the battery voltage between 12 and 10 YES NO<br />
1. If the battery less then 12 voltage:<br />
2. Clean the solar panel.<br />
3. Is the solar panel voltage more then 15 volt DC YES NO<br />
4. If the voltage is very low, change solar panel.<br />
5. Is there AC supply at the side YES NO<br />
6. Is the output voltage 13 voltage from AC charger YES NO<br />
7. If there is no DC output from charger check the fuse.<br />
8. If the fuse burned, replace fuse.<br />
9. If there is still no output, replace charger.<br />
10. Is output from regulator IS 12 vdc YES NO<br />
11. If there is no output, replace regulator.<br />
12. If AC charger/solar panel/sun regulator are ok, and the battery voltage doesn’t<br />
increase, replace battery.<br />