Cable Assemblies for OM3 / OM4<br />
OM3-P30 805 151 Power Supply Cable 3.0m<br />
OM3-P60 805 152 Power Supply Cable 6.0m<br />
OM3-N30 805 141 Relay Cable 3.0m<br />
OM3-N60 805 142 Relay Cable 6.0m OM3-Nxx<br />
Accessories<br />
OM3-Pxx<br />
ECT-323 804 424 Transformer 230 VAC / 24 VAC, 25 VA (supply of 1 pcs. OM3/OM4)<br />
ECT-623 804 421 Transformer 230 VAC / 24 VAC, 60 VA (supply of 3 pcs. OM3/OM4)<br />
ODP-33A 800 366 Differential oil check valve 3.5 bar, inlet: 15 / 16<br />
-18 UNF female, outlet: 5 / 8<br />
-18 UNF male<br />
Ordering Information (Example)<br />
Standard system requires the following parts:<br />
Type Part No. Description<br />
OM3-CUA 805 030 Oil level system with flange adapter 3- / 4-hole<br />
OM3-P30 805 151 Power Supply Cable 3.0m<br />
OM3-N30 805 141 Relay Cable 3.0m<br />
ECT-323 804 424 Transformer 230 VAC / 24 VAC, 25 VA<br />
ODP-33A 800 366 Differential Oil Check Valve 3.5 bar<br />
ODP-33A<br />
Technical Data<br />
Supply voltage / current<br />
24 V AC, 50/60 Hz / 0.7 A<br />
Maximum working pressure PS OM3: 31 bar, OM4: 43 bar<br />
Solenoid valve MOPD<br />
OM3: 21 bar, OM4: 24 bar<br />
Medium temperature -20 to 80°C<br />
Ambient temperature -20 to 50°C<br />
Time delay filling<br />
10 s<br />
Time delay alarm<br />
20 s<br />
Body material<br />
Aluminum<br />
Screw material<br />
stainless steel<br />
Medium compatibility HCFC, HFC, mineral, synthetic,<br />
and ester lubricants<br />
Orientation of base unit horizontal<br />
Level Control<br />
40 to 60% of sightglass height<br />
Protection class IP 65 (IEC529/EN 60529)<br />
Solenoid Coil<br />
ALCO ASC 24 VAC, 50/60 Hz: 8VA<br />
Weight<br />
850 … 930g (dep. on adapter)<br />
Alarm contact<br />
max. 3A, 230VAC,<br />
SPDT dry contact<br />
Application<br />
Traditional low pressure oil level management system<br />
1: Differential pressure valve<br />
2: Oil reservoir<br />
3: Condenser<br />
4: Filter Drier<br />
5: Common Discharge<br />
6: Common Suction Normal Temp<br />
7: Suction Line Low Temp<br />
8: Oil Separator<br />
OM3/OM4 Traxoil<br />
High pressure oil level management system<br />
1: Common Suction<br />
2: Common Discharge<br />
3: Condenser<br />
4: Filter Drier<br />
5: Oil Separator<br />
OM3/OM4 Traxoil<br />
144<br />
A2.5.1/0810/E