<strong>Alco</strong> <strong>Controls</strong><br />

Cable Assemblies for OM3 / OM4<br />

OM3-P30 805 151 Power Supply Cable 3.0m<br />

OM3-P60 805 152 Power Supply Cable 6.0m<br />

OM3-N30 805 141 Relay Cable 3.0m<br />

OM3-N60 805 142 Relay Cable 6.0m OM3-Nxx<br />

Accessories<br />

OM3-Pxx<br />

ECT-323 804 424 Transformer 230 VAC / 24 VAC, 25 VA (supply of 1 pcs. OM3/OM4)<br />

ECT-623 804 421 Transformer 230 VAC / 24 VAC, 60 VA (supply of 3 pcs. OM3/OM4)<br />

ODP-33A 800 366 Differential oil check valve 3.5 bar, inlet: 15 / 16<br />

-18 UNF female, outlet: 5 / 8<br />

-18 UNF male<br />

Ordering Information (Example)<br />

Standard system requires the following parts:<br />

Type Part No. Description<br />

OM3-CUA 805 030 Oil level system with flange adapter 3- / 4-hole<br />

OM3-P30 805 151 Power Supply Cable 3.0m<br />

OM3-N30 805 141 Relay Cable 3.0m<br />

ECT-323 804 424 Transformer 230 VAC / 24 VAC, 25 VA<br />

ODP-33A 800 366 Differential Oil Check Valve 3.5 bar<br />

ODP-33A<br />

Technical Data<br />

Supply voltage / current<br />

24 V AC, 50/60 Hz / 0.7 A<br />

Maximum working pressure PS OM3: 31 bar, OM4: 43 bar<br />

Solenoid valve MOPD<br />

OM3: 21 bar, OM4: 24 bar<br />

Medium temperature -20 to 80°C<br />

Ambient temperature -20 to 50°C<br />

Time delay filling<br />

10 s<br />

Time delay alarm<br />

20 s<br />

Body material<br />

Aluminum<br />

Screw material<br />

stainless steel<br />

Medium compatibility HCFC, HFC, mineral, synthetic,<br />

and ester lubricants<br />

Orientation of base unit horizontal<br />

Level Control<br />

40 to 60% of sightglass height<br />

Protection class IP 65 (IEC529/EN 60529)<br />

Solenoid Coil<br />

ALCO ASC 24 VAC, 50/60 Hz: 8VA<br />

Weight<br />

850 … 930g (dep. on adapter)<br />

Alarm contact<br />

max. 3A, 230VAC,<br />

SPDT dry contact<br />

Application<br />

Traditional low pressure oil level management system<br />

1: Differential pressure valve<br />

2: Oil reservoir<br />

3: Condenser<br />

4: Filter Drier<br />

5: Common Discharge<br />

6: Common Suction Normal Temp<br />

7: Suction Line Low Temp<br />

8: Oil Separator<br />

OM3/OM4 Traxoil<br />

High pressure oil level management system<br />

1: Common Suction<br />

2: Common Discharge<br />

3: Condenser<br />

4: Filter Drier<br />

5: Oil Separator<br />

OM3/OM4 Traxoil<br />

144<br />

A2.5.1/0810/E