STEAMPlus Sterilization Integrator<br />

STEAMPlus is an immediate readout integrator for use in gravity, prevacuum and<br />

flash cycles. This product is tested to ST-60 and ISO 11140-1:2005 performance<br />

claims of Class 5 integrating integrators. Four inch strip has distinct pass/fail<br />

criteria and allows for easy removal from packs. The STEAMPlus is FDA cleared<br />

as, equivalent in performance to a biological indicator, and offers the highest level of<br />

sterility assurance from a chemical indicator. The STEAMPlus does not replace the<br />

routine use of a biological indicator.<br />

Unprocessed<br />

Cat. No. Description UOM<br />

SSI-100 STEAMPlus Sterilization Integrator 100/pk<br />

SSI-1000 STEAMPlus Sterilization Integrator 1000/pk<br />

Processed<br />

STEAMPlus Sterilizer Test Pack<br />

STEAMPlus Sterilizer Test Pack has a STEAMPlus Sterilization Integrator<br />

inside a challenge pack for immediate load release of gravity and prevacuum<br />

sterilization cycles. This product tests to ensure all parameters for sterilization<br />

have been met, and is FDA cleared as equivalent in performance to an AAMI<br />

BI Test Pack (PCD). For the highest level of sterility assurance, a STEAMPlus<br />

Sterilizer Test Pack should be run in every load. Loads containing implantable<br />

devices should include a BI Test Pack such as the SporViewPlus (see page 4).<br />

Cat. No. Description UOM<br />

STP-025 STEAMPlus Sterilizer Test Pack 25/cs<br />

Steam - Hospital Style<br />

STEAMPlus Tray Record Card<br />

When flash sterilization is unavoidable, utilize the Tray Record Card for<br />

documenting the sterilization cycle with patient traceability. The immediate<br />

readout STEAMPlus Sterilization Integrator is attached to a 3” x 5” card<br />

which allows for cycle parameters, load number and patient name to be<br />

recorded and kept as a permanent record. Release load immediately with<br />

peace of mind that parameters for sterilization have been met and maintain<br />

this card as a physical record of the sterilization cycle.<br />

Cat. No. Description UOM<br />

TRC-050 STEAMPlus Tray Record Card 50/bx<br />

www.spsmedical.com • info@spsmedical.com (800) 722-1529 • (585) 359-0130 3