21 June 2013<br />

Wilson Matos<br />

<strong>Broughton</strong> <strong>Construction</strong> <strong>Company</strong><br />

1050 17 th Street NW, Suite 440<br />

Washington, DC 20036<br />

RE:<br />

MC KINLEY MIDDLE SCHOOL<br />

WASHINGTON, DC<br />

31207900<br />

Subject: Architect's Supplemental Instructions #<strong>017</strong> – <strong>Railing</strong> <strong>Extension</strong> Detail<br />

Dear Wilson:<br />

The enclosed <strong>ASI</strong>-<strong>017</strong>, <strong>Railing</strong> <strong>Extension</strong> Detail, supplies a solution to a safety concern<br />

associated with the location of the FCUs in the Stairs.<br />

We are concerned that occupants (students) could hurt themselves on the corner of the FCU<br />

units given their close location to the stair tread. Refer to the attached sketch, ASK-051, for<br />

our solution.<br />

All contract documents and other directives remain unchanged except the drawings and<br />

specifications added to, revised, deleted or clarified by this Instruction.<br />

The instructions to the constructor are as follows:<br />

1. Provide the rail extension detailed in attached sketch ASK-051 at all locations where<br />

the FCU is less than 44” from the stair tread.<br />

2. Paint the rail extension(s) to match the existing railing.<br />

Cordially,<br />

Quinn Evans Architects<br />

Tracy L.W. Hucul, RA


FCU<br />

2<br />

ASK-051<br />

EXISTING RAIL<br />

W/ BRACKETS<br />

NEW RAIL<br />

BASE PLATE WITH<br />

METAL SLEEVE<br />

EXISTING STAIR<br />

1 RAILING DETAIL ELEVATION<br />

ASK-051<br />

3/4" = 1'-0"<br />

NEW RAIL<br />

WELDED<br />

CONNECTION<br />

1<br />

ASK-051<br />

FCU<br />

WELDED<br />

CONNECTION TO<br />

EXISTING RIAILING<br />

EXISTING RAIL &<br />

BRACKET<br />

FCU<br />

BASE PLATE<br />

WITH METAL<br />

SLEEVE<br />

ALIGN<br />

NEW RAILING<br />

EXTENSION<br />

STEEL PLATE &<br />

COVER PLATE<br />

EXISTING RAILING<br />

& BRACKETS<br />

EXISTING STAIR<br />

2 SECTION DETAIL<br />

ASK-051<br />

3/4" = 1'-0"<br />

3 PLAN DETAIL<br />

ASK-051<br />

3/4" = 1'-0"<br />

REFER TO RFI <strong>ASI</strong>-<strong>017</strong> <strong>ASI</strong>-051 FOR MORE INFORMATION.<br />

QUINN EVANS ARCHITECTS<br />

2121 WARD PLACE NW, 4TH FLOOR<br />

WASHINGTON DC 20037<br />

(202) 298-6700<br />

Scale:<br />

THIS SKETCH MODIFIES DRAWING<br />

MC KINLEY MIDDLE SCHOOL<br />

151 T STREET NE<br />

WASHINGTON, DC<br />

DATED<br />

31207900<br />

21 JUNE 2013<br />

Sketch Number:<br />

3/4" = 1'-0" RAILING EXTENSION DETAIL AT FCU<br />

ASK-051

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!