Lightning and Surge Protection<br />

PowerPro BCD (Reducing Follow-on current)<br />

PP BCD TN 25/50 /LED(/FM)<br />

-350<br />

Combined two-pole TOV resistant Lightning Current and Surge Voltage Protective Device<br />

protection class I+II+III T1 T2 T3 (BCD),<br />

Used as equipotential bonding lightning and surge protection in single phase TN-Power Net Systems<br />

• Combined 2-pole modular Lightning Current + Surge Voltage Protective SPD, fully<br />

pre-connected and leakage current free<br />

• Fully based on patented hermetically sealed gas-filled Multi-chamber spark-gaps<br />

• No blow-out vents, no distances for safety installation required<br />

• Highly resistant against danger TOV, as no MOV to phase<br />

• Protection level ≤ 1 kV<br />

• Lightning current test level 25 kA (10/350 µs) per phase,<br />

• High self-extinguishing capability without tripping fuses<br />

• High insulation resistance R isol > 10 G Ω<br />

• Serial wiring with multifunctional screw terminal<br />

• LED for direct optical function monitoring built in<br />

• Remote monitoring by built-in potential-free /FM remote signal sensor (optional)<br />

Product description:<br />

This combined two-pole SPD type PP BCD TN 25/50/LED-350 and PP BCD TN 25/50/LED/FM-350, with remote<br />

signal contacts as well as LED monitoring, offers a complete solution for the protection of single phase TN-Power<br />

Net Systems. They are usually installed in main- or sub-distribution panels or close to equipments to be<br />

protected.<br />

Thanks to the use of the patented, hermetically sealed inert-gas-filled isolating spark-gaps, this SPD allows to<br />

achieve a very high-level discharge capacity without needing blow-out vents. This saves you from keeping the<br />

safety distance to adjoining electrical components usually necessary to avoid electric arcs and fire hazardous.<br />

As there is no risk of leakage currents, this SPD can also be installed before the electric power meter (acc. to<br />

TAB2000, installation rules of the German Union of Electric Energy Suppliers).<br />

This 2-pole SPD is capable to discharge lightning current surges of 25 kA (10/350µs) per phase and totally 50 kA<br />

(10/350µs) to PE.<br />

It self-extinguishes main supply follow-on currents up to 4 kA, so that even small fuses (>35A) will not trip.<br />

Each protective spark gap is installed in an easy-to-handle compact DIN size housing with 2 fixable snap-on clips<br />

for 35 mm DIN rail mounting on each SPD-module. Multifunctional large dimensioned screw terminals for wireand<br />

bus-bar connections. Line installation can be carried out either by parallel wiring via the multifunctional screw<br />

connection terminal L, N, or by serial V-wiring via the terminals L,N to L’,N´ connected with the two-pole busbars.<br />

Optional a sealed potential-free remote signal sensor (/FM) with thermal NC safety function can be built-in. The<br />

wire connection is made via a pluggable screw terminal block.<br />

Protects People and Valuables


Technical Data:<br />

Application:<br />

Lightning current and Surge Protective Device for single phase TN-Power Net Systems protection class<br />

I+II+III T1 T2 T3 (BCD), built in LED indication for function monitoring<br />

Type<br />

PP BCD<br />

PP BCD<br />

TN 25/50/LED -350 TN25/50/LED/FM -350<br />

Article number 38 51 00 38 51 10<br />

IEC 61643-1<br />

EN 61643-11<br />

E DIN VDE 0675-6 11/98-A1<br />

SPD class I+II+III<br />

SPD type T1 + T2 + T3<br />

BCD<br />

Nominal voltage of AC net 50/60 Hz U n [V~] 230 / 400 or 240 / 415<br />

Rated voltage (max. continuous operating voltage) 50/60 Hz U c [V~] 350<br />

Insulation resistance R isol [GΩ] > 10<br />

Voltage protection level L,N-PE at lightning impulse<br />

spark over voltage (1,2/50µs, Uoc 6kV)<br />

U as [kV] ≤ 1,0<br />

Voltage protection level at I imp U p [kV] ≤ 1,0<br />

Response time t A [ns] < 50<br />

Lightning impulse current I imp (10/350µs)<br />

[kA]<br />

[As]<br />

[kJ/Ω]<br />

Follow current extinguishing capability at U c I f [kA peak ] 4,0<br />

I peak<br />

Q<br />

W/R<br />

L, N - PE:<br />

25<br />

12,5<br />

160<br />

Short-circuit withstand capability at max. pre-fuse I k [kA rms ] 50<br />

Max. permissible line or back fuse F2 at parallel wiring [A] 250 A gL/gG<br />

Max. permissible line resp. back fuse F3 at serial wiring [A] 125 A gL/gG<br />

Operating temperature range T U [°C] -40 … +85<br />

Max. cross-sectional area [mm²] solid or stranded 50 / flexible 35<br />

Min. required / Recommended cross sectional area [mm²] Solid, stranded ore flexible…….. 10 / 25<br />

Recommended connection torque [Nm] 4,5<br />

Max. cross-sectional area for remote signal contact [mm²] 1,5<br />

Max. switching capacity of remote signal contact<br />

Material of housing / colour<br />

250V/0,5A<br />

Polycarbonate (halogen free) UL 94-V0 / yellow<br />

Environment protection category IP 20 (IEC/EN 60529)<br />

Mounting on 35 mm DIN rail form C (DIN/EN 50 022)<br />

Dimensions in mm / Diagram<br />

Dimension 2x 2 DIN-modules, acc. DIN 43880<br />

Application:<br />

If line or backup fuse (F1) is ≤ 250 A gL/gG,<br />

a back up fuse (F2) is not forced.<br />

Parallel wiring<br />

for active<br />

lines<br />

two-pol. bus-bar<br />

connection<br />

Line or backup fuse (F3) ≤ 125 A gL/gG<br />

Serial wiring<br />

for active<br />

lines<br />

PP BCD TN 25/50/LED/FM -350<br />

24.04.2007_pdf<br />

© 2007 by LEUTRON <strong>GmbH</strong><br />

Subject to technical modifications and<br />

delivery possibilities<br />

LEUTRON <strong>GmbH</strong><br />

Lightning- and Surge Protection<br />

Humboldtstrasse 30-32<br />

D-70771 Leinfelden-Echterdingen<br />

GERMANY<br />

Telephone +49 711 / 9 47 71-0<br />

Fax +49 711 / 9 47 71-70<br />

Email: info@leutron.de<br />

www.leutron.de

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!