Project: NADP Site Survey Program<br />

Section B<br />

Revision: 1<br />

Date: March 2009<br />

Page 27 of 41<br />

• <strong>National</strong> Weather Service (NWS) Stick Precipitation Gage – SOP-EPW07061-1430<br />

EEMS will check the response of the gages as found over the range appropriate for the gage, and<br />

will attempt to repair and recalibrate any Belfort gage in which the difference between the applied<br />

depth and recorded depth is out of tolerance as defined in the NADP QAPP. Stick gages and<br />

electronic gages will not be adjusted.<br />

EEMS developed SOPs for conducting surveys of the different types of precipitation collectors<br />

found at NADP sites, including the collector sensor and motorbox:<br />

• ACM NTN and AIRMoN Precipitation Collector – SOP-EPW07061-1310<br />

• ACM MDN Precipitation Collector – SOP-EPW07061-1320<br />

• N-CON Precipitation Collector – SOP-EPW07061-1330<br />

EEMS developed SOPs for conducting surveys of the field laboratory activities, equipment and<br />

supplies found at NTN and AIRMoN NADP sites:<br />

• Ohaus Balance (or electronic scale) – SOP-EPW07061-1210<br />

• pH Meter – SOP-EPW07061-1220<br />

• Conductivity Meter – SOP-EPW07061-1230<br />

Field laboratory includes data that pertains to performance of the field laboratory equipment<br />

(bucket balance, pH measurement system and specific conductance measurement system), the<br />

inventory of supplies and recordkeeping by the site operator.<br />

For AIRMoN sites, CAL will provide EEMS with a simulated rain sample of known pH and<br />

specific conductance. EEMS will request from the site operator that he or she analyze the sample<br />

as though it were a regular weekly sample. EEMS will be able to assess the procedures executed<br />

by the site operator in completing this task.<br />

The methods developed and described in the performance survey SOPs are intended to be used to<br />

determine and ensure that data collected and recorded by the NADP conforms to the performance<br />

acceptance criteria established in the NADP QAPP. Table 3 is a summary of these performance<br />

acceptance criteria.<br />

Table 3. Performance Acceptance Criteria<br />

Site Measurement Survey Method Acceptance Criteria<br />

Belfort Precipitation Depth Standard weight ± 0.10 in<br />

ETI Precipitation Depth Standard weight 0.05 in<br />

OTT NADP Pluvio Precipitation Depth Standard weight 0.05 in<br />

Stick Precipitation Depth Standard volumetric addition 0.01 in<br />

File location<br />