23.01.2015 Views

UK / IRL - Mennekes Electric Ltd

UK / IRL - Mennekes Electric Ltd

UK / IRL - Mennekes Electric Ltd

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Switch disconnectors made of AMELAN ®<br />

Disconnecting property in acc. with EN 60947 (up to 690V). Finger protection in acc. with DIN 57106 / VDE 0106 T.100.<br />

Combination units Plugs and connectors Sockets<br />

Service<br />

Image<br />

Characteristics switch disconnector<br />

Title / description<br />

Switch disconnector<br />

rigid enclosures, ample space<br />

for wiring, padlocking facilities,<br />

excellent switching capacity,<br />

open terminals and captive<br />

terminal screws<br />

IP 67<br />

Std. Pack. Qty: 1<br />

without<br />

aux. contact<br />

Rated Current<br />

Ampere<br />

Poles<br />

Auxiliary<br />

contact<br />

BS Motor<br />

rating<br />

AC3/440V<br />

kilowatt<br />

Part numbers<br />

25 3 7.5 52241 MEG<br />

25 3 7.5 52242 MEG<br />

40 3 18.5 52243 MEG<br />

40 3 18.5 52244 MEG<br />

80 3 30.0 52245 MEG<br />

80 3 30.0 52246 MEG<br />

Products with additional aux. contact (1 x NO and 1 x NC).<br />

with<br />

aux. contact<br />

without<br />

aux. contact<br />

with<br />

aux. contact<br />

without<br />

aux. contact<br />

with<br />

aux. contact<br />

Part numbers<br />

52241 MEG 52242 MEG 52243 MEG 52244 MEG 52245 MEG 52246 MEG<br />

Rated operational voltage U e<br />

IEC / EN / VDE / SEV 690V 690V 690V<br />

Main switch: Isol. voltage up to 690V 690V 690V<br />

Rated continuous current l u<br />

IEC / EN / VDE 25A 40A 80A<br />

Rated operational current l e<br />

IEC / EN 25A 40A 80A<br />

Rated operational current at 50 up to 60 Hz<br />

AC-23A IEC / EN / VDE<br />

3 phase 220-240V 5.5 kW 11.0 kW 18.5 kW<br />

3 pole 380-440V 11.0 kW 22.0 kW 18.5 kW<br />

600-690V 11.0 kW 18.5 kW 30.0 kW<br />

AC-3 IEC / EN / VDE<br />

3 phase 220-240V 4.0 kW 7.5 kW 15.0 kW<br />

3 pole 380-440V 7.5 kW 18.5 kW 30.0 kW<br />

600-690V 7.5 kW 15.0 kW 30.0 kW<br />

Rated breaking capacity<br />

AC-23A / AC-3 motor switch 220-240V 220A 350A 550A<br />

380-440V 220A 350A 550A<br />

600-690V 135A 190A 285A<br />

Maximum fuse size (gL) 35A 63A 80A<br />

Terminal cross section<br />

Single / multiple wire min. 1.0 mm 2 4.0 mm 2 6.0 mm 2<br />

max. 6.0 mm 2 16.0 mm 2 35.0 mm 2<br />

Fine-strand wire with sleeve min. 0.75 mm 2 2.5 mm 2 6.0 mm 2<br />

max. 4.0 mm 2 10.0 mm 2 25.0 mm 2<br />

Characteristics auxiliary contacts<br />

Special plugs and sockets,<br />

accessories<br />

Part numbers 52242 MEG 52244 MEG 52246 MEG<br />

Auxiliary module 500V 690V 690V<br />

Rated operational voltage U e<br />

Rated continuous current l u<br />

16A 16A 16A<br />

Rated operational current l e<br />

220-240V<br />

AC-15A IEC / EN 380-440V 2.5A/1.5A 6A/3A 6A/4A<br />

Terminal cross section<br />

Single / multiple wire min. 1.0 mm 2 1.0 mm 2 1.0 mm 2<br />

Fine-strand wire with sleeve max. 1.5 mm 2 2.5 mm 2 2.5 mm 2<br />

84