Standard - WEKA AG
Standard - WEKA AG
Standard - WEKA AG
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>WEKA</strong> <strong>AG</strong>, CH-8344 Bäretswil & CH-2300 La Chaux-de-Fonds, Switzerland<br />
Phone +41 43 833 4343 - Fax +41 43 833 4329- Schürlistrasse 8, CH-8344 Bäretswil<br />
Phone +41 32 925 97 00 - Fax +41 32 926 54 22 - Allée du Quartz 1, CH-2300 La Chaux-de-Fonds<br />
<strong>WEKA</strong> Specification no. 19911004 – <strong>WEKA</strong> Cryogenic Valves<br />
info@weka-ag.ch - www.weka-ag.ch<br />
19. September 2007 - FHo / Page 2 of 7<br />
The valve actuator spindle is flexible clutched on the bellows inset. This design guarantees an optimised<br />
adaptability to any functions requested and protect the valve against any inaccuracies from the actuator. A manual<br />
drive or pneumatic, electrical or hydraulic actuator could be fitted.<br />
Beside the possibility to turn the actuators in any circumferential position - in case of restricted space on cold box<br />
plates - it also allows a later modification of actuators on mounted valves to fulfil new functions.<br />
3. Valve Actuators<br />
<strong>WEKA</strong> Cryogenic Valves are supplied with manual, pneumatic or electrical actuators for on/off (digital) or control<br />
functions. Actuator control accessories like limit switches, positioner, 3/2-way solenoid valves etc. are selected<br />
according to the specified valve function.<br />
Pneumatic and electrical actuators as well as their accessories are bought from selected proven manufacturers.<br />
However, all current products, as per the customer’s request, could be assembled on request. Also available are<br />
pneumatic- or hydraulic piston drives.<br />
Actuator size and system is derived by the valve size (DN), the specified service or shut off pressure pressure,<br />
the available supply of energy (air pressure, power) and the plant control system. Also to act are specifications<br />
about actuating time, fail function in case of loss of energy supply and other restrictions like x-ray radiation's or<br />
explosion proof areas.<br />
4. Manufacturing and Quality Assurance<br />
Based on our long-standing experience in design, manufacturing and testing of Cryogenic Components we are<br />
in a position to offer you a made-to-measure solution for almost any requirement.<br />
Apart from the latest state of the art production equipment such as CAD-systems, fully integrated PPS with online<br />
BDE-system, CNC machine tools, TIG- (GTAW) welding equipment as well as He-leak tightness detector,<br />
ultra-sonic cleaning bath and separated assembling and testing rooms, we also maintain a appropriate QAsystem.<br />
The welding shop is qualified according to EN-, SVTI-, AD- and ANSI/ASME codes.<br />
<strong>WEKA</strong> Cryogenic Valves are individually He- leak tested over the valve seat and to outside, both under vacuum<br />
and pressure conditions. Valve bodies additionally are hydrostatic- or gas pressure tested. All these tests are<br />
executed, if possible, on the completely fitted valve and according to written procedures specifications.<br />
A end check of all valve function, dimensions, completeness of all accessories as well as adjusting of actuators<br />
and cleanliness of fluid contacted surfaces is carried out prior to despatch.<br />
For despatching the valves are packed in PE bags.<br />
All tests indicated above are specified in detail in the "<strong>Standard</strong> Delivery Specification for Cryogenic- and Bellows<br />
Sealed Valves"<br />
Additional tests and inspections according to customer’s request will be possible.<br />
L:\_Dokumentationen\Cryo_Datenblätter\_Originale\19911004-E-2002.doc