<strong>WEKA</strong> <strong>AG</strong>, CH-8344 Bäretswil & CH-2300 La Chaux-de-Fonds, Switzerland<br />
Phone +41 43 833 4343 - Fax +41 43 833 4329- Schürlistrasse 8, CH-8344 Bäretswil<br />
Phone +41 32 925 97 00 - Fax +41 32 926 54 22 - Allée du Quartz 1, CH-2300 La Chaux-de-Fonds<br />
<strong>WEKA</strong> Specification no. 19911004 – <strong>WEKA</strong> Cryogenic Valves<br />
info@weka-ag.ch - www.weka-ag.ch<br />
19. September 2007 - FHo / Page 6 of 7<br />
Heat load by thermal conductivity of solids on cryogenic valves PN25 (<strong>Standard</strong>)<br />
Heat load for any cryogenic length “h”:<br />
I<br />
L(h = )<br />
IL(h = 875,300 K − K) × 875<br />
=<br />
( W )<br />
h = <br />
h<br />
(mm)<br />
DN2, DN4, DN6 600<br />
875<br />
DN8 600<br />
875<br />
DN10 600<br />
875<br />
DN15 600<br />
875<br />
DN20 600<br />
875<br />
DN25 600<br />
875<br />
DN32 600<br />
875<br />
DN40-36 600<br />
875<br />
DN40 600<br />
875<br />
DN50 600<br />
875<br />
DN65 600<br />
875<br />
DN80 875<br />
1000<br />
DN100 875<br />
1000<br />
DN125 875<br />
1200<br />
DN150 875<br />
1200<br />
I L (300K-4K)<br />
(W)<br />
0.28<br />
0.19<br />
0.42<br />
0.29<br />
0.48<br />
0.33<br />
0.69<br />
0.47<br />
0.94<br />
0.64<br />
1.37<br />
0.94<br />
1.54<br />
1.06<br />
2.19<br />
1.50<br />
2.92<br />
2.01<br />
3.79<br />
2.60<br />
5.35<br />
3.67<br />
5.24<br />
4.58<br />
7.35<br />
6.41<br />
10.08<br />
7.24<br />
14.51<br />
10.39<br />
I L (300K-20K)<br />
(W)<br />
0.27<br />
0.19<br />
0.41<br />
0.28<br />
0.47<br />
0.32<br />
0.68<br />
0.46<br />
0.93<br />
0.63<br />
1.36<br />
0.93<br />
1.53<br />
1.05<br />
2.18<br />
1.49<br />
2.91<br />
1.99<br />
3.77<br />
2.59<br />
5.32<br />
3.65<br />
5.21<br />
4.56<br />
7.31<br />
6.37<br />
10.03<br />
7.21<br />
14.44<br />
10.34<br />
I L (300K-77K)<br />
(W)<br />
0.25<br />
0.17<br />
0.37<br />
0.26<br />
0.43<br />
0.30<br />
0.62<br />
0.42<br />
0.84<br />
0.58<br />
1.23<br />
0.84<br />
1.38<br />
0.95<br />
1.97<br />
1.35<br />
2.62<br />
2.33<br />
3.40<br />
2.33<br />
4.79<br />
3.29<br />
4.69<br />
4.11<br />
6.65<br />
5.79<br />
9.14<br />
6.56<br />
13.18<br />
9.42<br />
L:\_Dokumentationen\Cryo_Datenblätter\_Originale\19911004-E-2002.doc